1
|
Månsson A. The potential of myosin and actin in nanobiotechnology. J Cell Sci 2023; 136:292584. [PMID: 36861886 DOI: 10.1242/jcs.261025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/03/2023] Open
Abstract
Since the late 1990s, efforts have been made to utilize cytoskeletal filaments, propelled by molecular motors, for nanobiotechnological applications, for example, in biosensing and parallel computation. This work has led to in-depth insights into the advantages and challenges of such motor-based systems, and has yielded small-scale, proof-of-principle applications but, to date, no commercially viable devices. Additionally, these studies have also elucidated fundamental motor and filament properties, as well as providing other insights obtained from biophysical assays in which molecular motors and other proteins are immobilized on artificial surfaces. In this Perspective, I discuss the progress towards practically viable applications achieved so far using the myosin II-actin motor-filament system. I also highlight several fundamental pieces of insights derived from the studies. Finally, I consider what may be required to achieve real devices in the future or at least to allow future studies with a satisfactory cost-benefit ratio.
Collapse
Affiliation(s)
- Alf Månsson
- Department of Chemistry and Biomedical Science, Linnaeus University, SE-391 82 Kalmar, Sweden
| |
Collapse
|
2
|
Critical Evaluation of Current Hypotheses for the Pathogenesis of Hypertrophic Cardiomyopathy. Int J Mol Sci 2022; 23:ijms23042195. [PMID: 35216312 PMCID: PMC8880276 DOI: 10.3390/ijms23042195] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Revised: 02/07/2022] [Accepted: 02/14/2022] [Indexed: 02/04/2023] Open
Abstract
Hereditary hypertrophic cardiomyopathy (HCM), due to mutations in sarcomere proteins, occurs in more than 1/500 individuals and is the leading cause of sudden cardiac death in young people. The clinical course exhibits appreciable variability. However, typically, heart morphology and function are normal at birth, with pathological remodeling developing over years to decades, leading to a phenotype characterized by asymmetric ventricular hypertrophy, scattered fibrosis and myofibrillar/cellular disarray with ultimate mechanical heart failure and/or severe arrhythmias. The identity of the primary mutation-induced changes in sarcomere function and how they trigger debilitating remodeling are poorly understood. Support for the importance of mutation-induced hypercontractility, e.g., increased calcium sensitivity and/or increased power output, has been strengthened in recent years. However, other ideas that mutation-induced hypocontractility or non-uniformities with contractile instabilities, instead, constitute primary triggers cannot yet be discarded. Here, we review evidence for and criticism against the mentioned hypotheses. In this process, we find support for previous ideas that inefficient energy usage and a blunted Frank–Starling mechanism have central roles in pathogenesis, although presumably representing effects secondary to the primary mutation-induced changes. While first trying to reconcile apparently diverging evidence for the different hypotheses in one unified model, we also identify key remaining questions and suggest how experimental systems that are built around isolated primarily expressed proteins could be useful.
Collapse
|
3
|
van Delft FCMJM, Ipolitti G, Nicolau DV, Sudalaiyadum Perumal A, Kašpar O, Kheireddine S, Wachsmann-Hogiu S, Nicolau DV. Something has to give: scaling combinatorial computing by biological agents exploring physical networks encoding NP-complete problems. Interface Focus 2018; 8:20180034. [PMID: 30443332 PMCID: PMC6227808 DOI: 10.1098/rsfs.2018.0034] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/13/2018] [Indexed: 12/19/2022] Open
Abstract
On-chip network-based computation, using biological agents, is a new hardware-embedded approach which attempts to find solutions to combinatorial problems, in principle, in a shorter time than the fast, but sequential electronic computers. This analytical review starts by describing the underlying mathematical principles, presents several types of combinatorial (including NP-complete) problems and shows current implementations of proof of principle developments. Taking the subset sum problem as example for in-depth analysis, the review presents various options of computing agents, and compares several possible operation 'run modes' of network-based computer systems. Given the brute force approach of network-based systems for solving a problem of input size C, 2C solutions must be visited. As this exponentially increasing workload needs to be distributed in space, time, and per computing agent, this review identifies the scaling-related key technological challenges in terms of chip fabrication, readout reliability and energy efficiency. The estimated computing time of massively parallel or combinatorially operating biological agents is then compared to that of electronic computers. Among future developments which could considerably improve network-based computing, labelling agents 'on the fly' and the readout of their travel history at network exits could offer promising avenues for finding hardware-embedded solutions to combinatorial problems.
Collapse
Affiliation(s)
| | - Giulia Ipolitti
- Department of Bioengineering, McGill University, Montreal, Quebec, Canada H3A 0E9
| | - Dan V. Nicolau
- Molecular Sense Ltd, Liverpool L36 8HT, UK
- School of Mathematical Sciences, Queensland University of Technology, Brisbane, QLD 4000, Australia
| | | | - Ondřej Kašpar
- Department of Bioengineering, McGill University, Montreal, Quebec, Canada H3A 0E9
- Department of Chemical Engineering, University of Chemistry and Technology, Prague, Technická 5, 166 28 Prague 6, Czech Republic
| | - Sara Kheireddine
- Department of Bioengineering, McGill University, Montreal, Quebec, Canada H3A 0E9
| | | | - Dan V. Nicolau
- Department of Bioengineering, McGill University, Montreal, Quebec, Canada H3A 0E9
| |
Collapse
|
4
|
Lindberg FW, Norrby M, Rahman MA, Salhotra A, Takatsuki H, Jeppesen S, Linke H, Månsson A. Controlled Surface Silanization for Actin-Myosin Based Nanodevices and Biocompatibility of New Polymer Resists. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2018; 34:8777-8784. [PMID: 29969272 DOI: 10.1021/acs.langmuir.8b01415] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Molecular motor-based nanodevices require organized cytoskeletal filament guiding along motility-promoting tracks, confined by motility-inhibiting walls. One way to enhance motility quality on the tracks, particularly in terms of filament velocity but also the fraction of motile filaments, is to optimize the surface hydrophobicity. We have investigated the potential to achieve this for the actin-myosin II motor system on trimethylchlorosilane (TMCS)-derivatized SiO2 surfaces to be used as channel floors in nanodevices. We have also investigated the ability to supress motility on two new polymer resists, TU7 (for nanoimprint lithography) and CSAR 62 (for electron beam and deep UV lithography), to be used as channel walls. We developed a chemical-vapor deposition tool for silanizing SiO2 surfaces in a controlled environment to achieve different surface hydrophobicities (measured by water contact angle). In contrast to previous work, we were able to fabricate a wide range of contact angles by varying the silanization time and chamber pressure using only one type of silane. This resulted in a significant improvement of the silanization procedure, producing a predictable contact angle on the surface and thereby predictable quality of the heavy meromyosin (HMM)-driven actin motility with regard to velocity. We observed a high degree of correlation between the filament sliding velocity and contact angle in the range 10-86°, expanding the previously studied range. We found that the sliding velocity on TU7 surfaces was superior to that on CSAR 62 surfaces despite similar contact angles. In addition, we were able to suppress the motility on both TU7 and CSAR 62 by plasma oxygen treatment before silanization. These results are discussed in relation to previously proposed surface adsorption mechanisms of HMM and their relationship to the water contact angle. Additionally, the results are considered for the development of actin-myosin based nanodevices with superior performance with respect to actin-myosin functionality.
Collapse
Affiliation(s)
- Frida W Lindberg
- NanoLund and Solid State Physics , Lund University , Box 118, Lund SE-221 00 , Sweden
| | - Marlene Norrby
- Department of Chemistry and Biomedical Sciences , Linnaeus University , Kalmar SE-391 82 , Sweden
| | - Mohammad A Rahman
- Department of Chemistry and Biomedical Sciences , Linnaeus University , Kalmar SE-391 82 , Sweden
| | - Aseem Salhotra
- Department of Chemistry and Biomedical Sciences , Linnaeus University , Kalmar SE-391 82 , Sweden
| | - Hideyo Takatsuki
- Department of Chemistry and Biomedical Sciences , Linnaeus University , Kalmar SE-391 82 , Sweden
| | - Sören Jeppesen
- NanoLund and Solid State Physics , Lund University , Box 118, Lund SE-221 00 , Sweden
| | - Heiner Linke
- NanoLund and Solid State Physics , Lund University , Box 118, Lund SE-221 00 , Sweden
| | - Alf Månsson
- Department of Chemistry and Biomedical Sciences , Linnaeus University , Kalmar SE-391 82 , Sweden
| |
Collapse
|
5
|
Kumar S, Mansson A. Covalent and non-covalent chemical engineering of actin for biotechnological applications. Biotechnol Adv 2017; 35:867-888. [PMID: 28830772 DOI: 10.1016/j.biotechadv.2017.08.002] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2017] [Revised: 08/09/2017] [Accepted: 08/16/2017] [Indexed: 12/26/2022]
Abstract
The cytoskeletal filaments are self-assembled protein polymers with 8-25nm diameters and up to several tens of micrometres length. They have a range of pivotal roles in eukaryotic cells, including transportation of intracellular cargoes (primarily microtubules with dynein and kinesin motors) and cell motility (primarily actin and myosin) where muscle contraction is one example. For two decades, the cytoskeletal filaments and their associated motor systems have been explored for nanotechnological applications including miniaturized sensor systems and lab-on-a-chip devices. Several developments have also revolved around possible exploitation of the filaments alone without their motor partners. Efforts to use the cytoskeletal filaments for applications often require chemical or genetic engineering of the filaments such as specific conjugation with fluorophores, antibodies, oligonucleotides or various macromolecular complexes e.g. nanoparticles. Similar conjugation methods are also instrumental for a range of fundamental biophysical studies. Here we review methods for non-covalent and covalent chemical modifications of actin filaments with focus on critical advantages and challenges of different methods as well as critical steps in the conjugation procedures. We also review potential uses of the engineered actin filaments in nanotechnological applications and in some key fundamental studies of actin and myosin function. Finally, we consider possible future lines of investigation that may be addressed by applying chemical conjugation of actin in new ways.
Collapse
Affiliation(s)
- Saroj Kumar
- Department of Biotechnology, Delhi Technological University, Delhi 110042, India; Department of Chemistry and Biomedical Sciences, Faculty of Health and Life Sciences, Linnaeus University, SE-391 82 Kalmar, Sweden.
| | - Alf Mansson
- Department of Chemistry and Biomedical Sciences, Faculty of Health and Life Sciences, Linnaeus University, SE-391 82 Kalmar, Sweden.
| |
Collapse
|
6
|
Shroder DY, Lippert LG, Goldman YE. Single molecule optical measurements of orientation and rotations of biological macromolecules. Methods Appl Fluoresc 2016; 4:042004. [PMID: 28192292 PMCID: PMC5308470 DOI: 10.1088/2050-6120/4/4/042004] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Subdomains of macromolecules often undergo large orientation changes during their catalytic cycles that are essential for their activity. Tracking these rearrangements in real time opens a powerful window into the link between protein structure and functional output. Site-specific labeling of individual molecules with polarized optical probes and measurement of their spatial orientation can give insight into the crucial conformational changes, dynamics, and fluctuations of macromolecules. Here we describe the range of single molecule optical technologies that can extract orientation information from these probes, review the relevant types of probes and labeling techniques, and highlight the advantages and disadvantages of these technologies for addressing specific inquiries.
Collapse
|
7
|
Persson M, Bengtsson E, ten Siethoff L, Månsson A. Nonlinear cross-bridge elasticity and post-power-stroke events in fast skeletal muscle actomyosin. Biophys J 2013; 105:1871-81. [PMID: 24138863 PMCID: PMC3797597 DOI: 10.1016/j.bpj.2013.08.044] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2013] [Revised: 08/21/2013] [Accepted: 08/28/2013] [Indexed: 11/21/2022] Open
Abstract
Generation of force and movement by actomyosin cross-bridges is the molecular basis of muscle contraction, but generally accepted ideas about cross-bridge properties have recently been questioned. Of the utmost significance, evidence for nonlinear cross-bridge elasticity has been presented. We here investigate how this and other newly discovered or postulated phenomena would modify cross-bridge operation, with focus on post-power-stroke events. First, as an experimental basis, we present evidence for a hyperbolic [MgATP]-velocity relationship of heavy-meromyosin-propelled actin filaments in the in vitro motility assay using fast rabbit skeletal muscle myosin (28-29°C). As the hyperbolic [MgATP]-velocity relationship was not consistent with interhead cooperativity, we developed a cross-bridge model with independent myosin heads and strain-dependent interstate transition rates. The model, implemented with inclusion of MgATP-independent detachment from the rigor state, as suggested by previous single-molecule mechanics experiments, accounts well for the [MgATP]-velocity relationship if nonlinear cross-bridge elasticity is assumed, but not if linear cross-bridge elasticity is assumed. In addition, a better fit is obtained with load-independent than with load-dependent MgATP-induced detachment rate. We discuss our results in relation to previous data showing a nonhyperbolic [MgATP]-velocity relationship when actin filaments are propelled by myosin subfragment 1 or full-length myosin. We also consider the implications of our results for characterization of the cross-bridge elasticity in the filament lattice of muscle.
Collapse
Affiliation(s)
| | | | | | - Alf Månsson
- Department of Chemistry and Biomedical Sciences, Linnaeus University, Kalmar, Sweden
| |
Collapse
|
8
|
Bengtsson E, Persson M, Månsson A. Analysis of flexural rigidity of actin filaments propelled by surface adsorbed myosin motors. Cytoskeleton (Hoboken) 2013; 70:718-28. [PMID: 24039103 PMCID: PMC4230416 DOI: 10.1002/cm.21138] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2013] [Revised: 08/08/2013] [Accepted: 08/22/2013] [Indexed: 11/09/2022]
Abstract
Actin filaments are central components of the cytoskeleton and the contractile machinery of muscle. The filaments are known to exist in a range of conformational states presumably with different flexural rigidity and thereby different persistence lengths. Our results analyze the approaches proposed previously to measure the persistence length from the statistics of the winding paths of actin filaments that are propelled by surface-adsorbed myosin motor fragments in the in vitro motility assay. Our results suggest that the persistence length of heavy meromyosin propelled actin filaments can be estimated with high accuracy and reproducibility using this approach provided that: (1) the in vitro motility assay experiments are designed to prevent bias in filament sliding directions, (2) at least 200 independent filament paths are studied, (3) the ratio between the sliding distance between measurements and the camera pixel-size is between 4 and 12, (4) the sliding distances between measurements is less than 50% of the expected persistence length, and (5) an appropriate cut-off value is chosen to exclude abrupt large angular changes in sliding direction that are complications, e.g., due to the presence of rigor heads. If the above precautions are taken the described method should be a useful routine part of in vitro motility assays thus expanding the amount of information to be gained from these.
Collapse
Affiliation(s)
- Elina Bengtsson
- Faculty of Health and Life Sciences, Linnaeus University, Kalmar, Sweden
| | | | | |
Collapse
|
9
|
Ochala J, Iwamoto H, Ravenscroft G, Laing NG, Nowak KJ. Skeletal and cardiac α-actin isoforms differently modulate myosin cross-bridge formation and myofibre force production. Hum Mol Genet 2013; 22:4398-404. [PMID: 23784376 DOI: 10.1093/hmg/ddt289] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Multiple congenital myopathies, including nemaline myopathy, can arise due to mutations in the ACTA1 gene encoding skeletal muscle α-actin. The main characteristics of ACTA1 null mutations (absence of skeletal muscle α-actin) are generalized skeletal muscle weakness and premature death. A mouse model (ACTC(Co)/KO) mimicking these conditions has successfully been rescued by transgenic over-expression of cardiac α-actin in skeletal muscles using the ACTC gene. Nevertheless, myofibres from ACTC(Co)/KO animals generate less force than normal myofibres (-20 to 25%). To understand the underlying mechanisms, here we have undertaken a detailed functional study of myofibres from ACTC(Co)/KO rodents. Mechanical and X-ray diffraction pattern analyses of single membrane-permeabilized myofibres showed, upon maximal Ca(2+) activation and under rigor conditions, lower stiffness and disrupted actin-layer line reflections in ACTC(Co)/KO when compared with age-matched wild-types. These results demonstrate that in ACTC(Co)/KO myofibres, the presence of cardiac α-actin instead of skeletal muscle α-actin alters actin conformational changes upon activation. This later finely modulates the strain of individual actomyosin interactions and overall lowers myofibre force production. Taken together, the present findings provide novel primordial information about actin isoforms, their functional differences and have to be considered when designing gene therapies for ACTA1-based congenital myopathies.
Collapse
Affiliation(s)
- Julien Ochala
- Centre of Human and Aerospace Physiological Sciences, School of Biomedical Sciences, King's College London, Room 3.3, Shepherd's House, Guy's Campus, London SE1 1UL, UK
| | | | | | | | | |
Collapse
|
10
|
Magnetic capture from blood rescues molecular motor function in diagnostic nanodevices. J Nanobiotechnology 2013; 11:14. [PMID: 23638952 PMCID: PMC3660291 DOI: 10.1186/1477-3155-11-14] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2013] [Accepted: 04/29/2013] [Indexed: 01/29/2023] Open
Abstract
BACKGROUND Introduction of effective point-of-care devices for use in medical diagnostics is part of strategies to combat accelerating health-care costs. Molecular motor driven nanodevices have unique potentials in this regard due to unprecedented level of miniaturization and independence of external pumps. However motor function has been found to be inhibited by body fluids. RESULTS We report here that a unique procedure, combining separation steps that rely on antibody-antigen interactions, magnetic forces applied to magnetic nanoparticles (MPs) and the specificity of the actomyosin bond, can circumvent the deleterious effects of body fluids (e.g. blood serum). The procedure encompasses the following steps: (i) capture of analyte molecules from serum by MP-antibody conjugates, (ii) pelleting of MP-antibody-analyte complexes, using a magnetic field, followed by exchange of serum for optimized biological buffer, (iii) mixing of MP-antibody-analyte complexes with actin filaments conjugated with same polyclonal antibodies as the magnetic nanoparticles. This causes complex formation: MP-antibody-analyte-antibody-actin, and magnetic separation is used to enrich the complexes. Finally (iv) the complexes are introduced into a nanodevice for specific binding via actin filaments to surface adsorbed molecular motors (heavy meromyosin). The number of actin filaments bound to the motors in the latter step was significantly increased above the control value if protein analyte (50-60 nM) was present in serum (in step i) suggesting appreciable formation and enrichment of the MP-antibody-analyte-antibody-actin complexes. Furthermore, addition of ATP demonstrated maintained heavy meromyosin driven propulsion of actin filaments showing that the serum induced inhibition was alleviated. Detailed analysis of the procedure i-iv, using fluorescence microscopy and spectroscopy identified main targets for future optimization. CONCLUSION The results demonstrate a promising approach for capturing analytes from serum for subsequent motor driven separation/detection. Indeed, the observed increase in actin filament number, in itself, signals the presence of analyte at clinically relevant nM concentration without the need for further motor driven concentration. Our analysis suggests that exchange of polyclonal for monoclonal antibodies would be a critical improvement, opening for a first clinically useful molecular motor driven lab-on-a-chip device.
Collapse
|
11
|
Lard M, Ten Siethoff L, Kumar S, Persson M, Te Kronnie G, Linke H, Månsson A. Ultrafast molecular motor driven nanoseparation and biosensing. Biosens Bioelectron 2013; 48:145-52. [PMID: 23672875 DOI: 10.1016/j.bios.2013.03.071] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2013] [Revised: 03/27/2013] [Accepted: 03/28/2013] [Indexed: 11/29/2022]
Abstract
Portable biosensor systems would benefit from reduced dependency on external power supplies as well as from further miniaturization and increased detection rate. Systems built around self-propelled biological molecular motors and cytoskeletal filaments hold significant promise in these regards as they are built from nanoscale components that enable nanoseparation independent of fluidic pumping. Previously reported microtubule-kinesin based devices are slow, however, compared to several existing biosensor systems. Here we demonstrate that this speed limitation can be overcome by using the faster actomyosin motor system. Moreover, due to lower flexural rigidity of the actin filaments, smaller features can be achieved compared to microtubule-based systems, enabling further miniaturization. Using a device designed through optimization by Monte Carlo simulations, we demonstrate extensive myosin driven enrichment of actin filaments on a detector area of less than 10 μm², with a concentration half-time of approximately 40 s. We also show accumulation of model analyte (streptavidin at nanomolar concentration in nanoliter effective volume) detecting increased fluorescence intensity within seconds after initiation of motor-driven transportation from capture regions. We discuss further optimizations of the system and incorporation into a complete biosensing workflow.
Collapse
Affiliation(s)
- Mercy Lard
- The Nanometer Structure Consortium (nmC@LU), Division of Solid State Physics, Lund University, SE-22100 Lund, Sweden
| | | | | | | | | | | | | |
Collapse
|
12
|
Korten S, Albet-Torres N, Paderi F, ten Siethoff L, Diez S, Korten T, te Kronnie G, Månsson A. Sample solution constraints on motor-driven diagnostic nanodevices. LAB ON A CHIP 2013; 13:866-876. [PMID: 23303341 DOI: 10.1039/c2lc41099k] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
The last decade has seen appreciable advancements in efforts towards increased portability of lab-on-a-chip devices by substituting microfluidics with molecular motor-based transportation. As of now, first proof-of-principle devices have analyzed protein mixtures of low complexity, such as target protein molecules in buffer solutions optimized for molecular motor performance. However, in a diagnostic work-up, lab-on-a-chip devices need to be compatible with complex biological samples. While it has been shown that such samples do not interfere with crucial steps in molecular diagnostics (for example antibody-antigen recognition), their effect on molecular motors is unknown. This critical and long overlooked issue is addressed here. In particular, we studied the effects of blood, cell lysates and solutions containing genomic DNA extracts on actomyosin and kinesin-microtubule-based transport, the two biomolecular motor systems that are most promising for lab-on-a-chip applications. We found that motor function is well preserved at defined dilutions of most of the investigated biological samples and demonstrated a molecular motor-driven label-free blood type test. Our results support the feasibility of molecular-motor driven nanodevices for diagnostic point-of-care applications and also demonstrate important constraints imposed by sample composition and device design that apply both to kinesin-microtubule and actomyosin driven applications.
Collapse
Affiliation(s)
- Slobodanka Korten
- Max Planck Institute of Molecular Cell Biology and Genetics, Dresden, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
13
|
Persson M, Gullberg M, Tolf C, Lindberg AM, Månsson A, Kocer A. Transportation of nanoscale cargoes by myosin propelled actin filaments. PLoS One 2013; 8:e55931. [PMID: 23437074 PMCID: PMC3578877 DOI: 10.1371/journal.pone.0055931] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2012] [Accepted: 01/03/2013] [Indexed: 02/04/2023] Open
Abstract
Myosin II propelled actin filaments move ten times faster than kinesin driven microtubules and are thus attractive candidates as cargo-transporting shuttles in motor driven lab-on-a-chip devices. In addition, actomyosin-based transportation of nanoparticles is useful in various fundamental studies. However, it is poorly understood how actomyosin function is affected by different number of nanoscale cargoes, by cargo size, and by the mode of cargo-attachment to the actin filament. This is studied here using biotin/fluorophores, streptavidin, streptavidin-coated quantum dots, and liposomes as model cargoes attached to monomers along the actin filaments (“side-attached”) or to the trailing filament end via the plus end capping protein CapZ. Long-distance transportation (>100 µm) could be seen for all cargoes independently of attachment mode but the fraction of motile filaments decreased with increasing number of side-attached cargoes, a reduction that occurred within a range of 10–50 streptavidin molecules, 1–10 quantum dots or with just 1 liposome. However, as observed by monitoring these motile filaments with the attached cargo, the velocity was little affected. This also applied for end-attached cargoes where the attachment was mediated by CapZ. The results with side-attached cargoes argue against certain models for chemomechanical energy transduction in actomyosin and give important insights of relevance for effective exploitation of actomyosin-based cargo-transportation in molecular diagnostics and other nanotechnological applications. The attachment of quantum dots via CapZ, without appreciable modulation of actomyosin function, is useful in fundamental studies as exemplified here by tracking with nanometer accuracy.
Collapse
Affiliation(s)
- Malin Persson
- School of Natural Sciences, Linnaeus University, Kalmar, Sweden
| | | | | | | | | | | |
Collapse
|
14
|
Kumar S, ten Siethoff L, Persson M, Lard M, te Kronnie G, Linke H, Månsson A. Antibodies covalently immobilized on actin filaments for fast myosin driven analyte transport. PLoS One 2012; 7:e46298. [PMID: 23056279 PMCID: PMC3463588 DOI: 10.1371/journal.pone.0046298] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2012] [Accepted: 08/29/2012] [Indexed: 01/09/2023] Open
Abstract
Biosensors would benefit from further miniaturization, increased detection rate and independence from external pumps and other bulky equipment. Whereas transportation systems built around molecular motors and cytoskeletal filaments hold significant promise in the latter regard, recent proof-of-principle devices based on the microtubule-kinesin motor system have not matched the speed of existing methods. An attractive solution to overcome this limitation would be the use of myosin driven propulsion of actin filaments which offers motility one order of magnitude faster than the kinesin-microtubule system. Here, we realized a necessary requirement for the use of the actomyosin system in biosensing devices, namely covalent attachment of antibodies to actin filaments using heterobifunctional cross-linkers. We also demonstrated consistent and rapid myosin II driven transport where velocity and the fraction of motile actin filaments was negligibly affected by the presence of antibody-antigen complexes at rather high density (>20 µm(-1)). The results, however, also demonstrated that it was challenging to consistently achieve high density of functional antibodies along the actin filament, and optimization of the covalent coupling procedure to increase labeling density should be a major focus for future work. Despite the remaining challenges, the reported advances are important steps towards considerably faster nanoseparation than shown for previous molecular motor based devices, and enhanced miniaturization because of high bending flexibility of actin filaments.
Collapse
Affiliation(s)
- Saroj Kumar
- School of Natural Sciences, Linnaeus University, Kalmar, Sweden
| | | | - Malin Persson
- School of Natural Sciences, Linnaeus University, Kalmar, Sweden
| | - Mercy Lard
- The Nanometer Structure Consortium and Division of Solid State Physics, Lund University, Lund, Sweden
| | - Geertruy te Kronnie
- Department of Women’s and Children’s Health, University of Padua, Padova, Italy
| | - Heiner Linke
- The Nanometer Structure Consortium and Division of Solid State Physics, Lund University, Lund, Sweden
| | - Alf Månsson
- School of Natural Sciences, Linnaeus University, Kalmar, Sweden
- * E-mail:
| |
Collapse
|
15
|
Copeland O, Nowak KJ, Laing NG, Ravenscroft G, Messer AE, Bayliss CR, Marston SB. Investigation of changes in skeletal muscle alpha-actin expression in normal and pathological human and mouse hearts. J Muscle Res Cell Motil 2010; 31:207-14. [PMID: 20706863 DOI: 10.1007/s10974-010-9224-7] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2010] [Accepted: 07/21/2010] [Indexed: 10/19/2022]
Abstract
We have developed a quantitative antibody-based assay to measure the content of skeletal muscle alpha-actin relative to cardiac alpha-actin. We found 21 +/- 2% skeletal muscle alpha-actin content in normal heart muscle of adult man and mouse. In end stage failing heart 53 +/- 5% of striated actin was skeletal muscle alpha-actin and in samples of inter-ventricular septum from patients with hypertrophic obstructive cardiomyopathy (HOCM) skeletal muscle alpha-actin was 72 +/- 2% of sarcomeric actin. Thin filaments containing actin isolated from normal and HOCM heart muscle were functionally indistinguishable when studied by quantitative in vitro motility assay. We also found elevated skeletal muscle alpha-actin (60 +/- 7%) in a mouse model of dilated cardiomyopathy.
Collapse
Affiliation(s)
- O'Neal Copeland
- NHLI, Cardiovascular Science, Imperial College London, London, UK
| | | | | | | | | | | | | |
Collapse
|
16
|
Vikhorev PG, Vikhoreva NN, Sundberg M, Balaz M, Albet-Torres N, Bunk R, Kvennefors A, Liljesson K, Nicholls IA, Nilsson L, Omling P, Tågerud S, Montelius L, Månsson A. Diffusion dynamics of motor-driven transport: gradient production and self-organization of surfaces. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2008; 24:13509-17. [PMID: 18989944 DOI: 10.1021/la8016112] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
The interaction between cytoskeletal filaments (e.g., actin filaments) and molecular motors (e.g., myosin) is the basis for many aspects of cell motility and organization of the cell interior. In the in vitro motility assay (IVMA), cytoskeletal filaments are observed while being propelled by molecular motors adsorbed to artificial surfaces (e.g., in studies of motor function). Here we integrate ideas that cytoskeletal filaments may be used as nanoscale templates in nanopatterning with a novel approach for the production of surface gradients of biomolecules and nanoscale topographical features. The production of such gradients is challenging but of increasing interest (e.g., in cell biology). First, we show that myosin-induced actin filament sliding in the IVMA can be approximately described as persistent random motion with a diffusion coefficient (D) given by a relationship analogous to the Einstein equation (D = kT/gamma). In this relationship, the thermal energy (kT) and the drag coefficient (gamma) are substituted by a parameter related to the free-energy transduction by actomyosin and the actomyosin dissociation rate constant, respectively. We then demonstrate how the persistent random motion of actin filaments can be exploited in conceptually novel methods for the production of actin filament density gradients of predictable shapes. Because of regularly spaced binding sites (e.g., lysines and cysteines) the actin filaments act as suitable nanoscale scaffolds for other biomolecules (tested for fibronectin) or nanoparticles. This forms the basis for secondary chemical and topographical gradients with implications for cell biological studies and biosensing.
Collapse
Affiliation(s)
- Petr G Vikhorev
- School of Pure and Applied Natural Sciences, University of Kalmar, SE-391 82 Kalmar, Sweden
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Abstract
Muscle contraction and other forms of cell motility occur as a result of cyclic interactions between myosin molecules and actin filaments. Force generation is generally attributed to ATP-driven structural changes in myosin, whereas a passive role is ascribed to actin. However, some results challenge this view, predicting structural changes in actin during motor activity, e.g., when the actin filaments slide on a myosin-coated surface in vitro. Here, we analyzed statistical properties of the sliding filament paths, allowing us to detect changes of this type. It is interesting to note that evidence for substantial structural changes that led to increased bending flexibility of the filaments was found in phalloidin-stabilized, but not in phalloidin-free, actin filaments. The results are in accordance with the idea that a high-flexibility structural state of actin is a prerequisite for force production, but not the idea that a low-to-high flexibility transition of the actin filament should be an important component of the force-generating step per se. Finally, our data challenge the general view that phalloidin-stabilized filaments behave as native actin filaments in their interaction with myosin. This has important implications, since phalloidin stabilization is a routine procedure in most studies of actomyosin function.
Collapse
|
18
|
Sundberg M, Månsson A, Tågerud S. Contact angle measurements by confocal microscopy for non-destructive microscale surface characterization. J Colloid Interface Sci 2007; 313:454-60. [PMID: 17553514 DOI: 10.1016/j.jcis.2007.04.067] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2007] [Revised: 04/15/2007] [Accepted: 04/29/2007] [Indexed: 11/28/2022]
Abstract
Contact angle measurements are of great importance in surface characterization but the practical use has often been limited to macroscopic dimensions (millimeters). Therefore, we have developed a confocal microscopy method that allows non-destructive measurements of both low (<30 degrees ) and high (30 degrees -90 degrees ) contact angles. Low contact angles were measured by reconstructing the drop profile from the interference patterns in droplets condensed from atmospheric humidity. At higher contact angles water droplets with a small amount of fluorescein were sprayed onto the surfaces and 3D-image stacks were recorded and used to extract the contact angle. Suitable drop sizes were between a few up to about 50 mum radius, using a 40x magnification objective. Using drops >10 micrometers radius for microcontact angle measurements a good correlation was obtained between measured micro- and macrocontact angles. After microcontact angle measurements the surfaces were rinsed and heavy meromyosin motor fragments were adsorbed to the surface. Importantly, the sensitive actin propelling function of these motor proteins was not affected by the previous contact angle measurements using fluorescent droplets. This suggests that the methodology should be suitable for non-destructive characterization of different parts of micropatterned surfaces being developed for biological assays.
Collapse
Affiliation(s)
- Mark Sundberg
- School of Pure and Applied Natural Sciences, University of Kalmar, SE-391 82 Kalmar, Sweden.
| | | | | |
Collapse
|
19
|
|
20
|
Sundberg M, Bunk R, Albet-Torres N, Kvennefors A, Persson F, Montelius L, Nicholls IA, Ghatnekar-Nilsson S, Omling P, Tågerud S, Månsson A. Actin filament guidance on a chip: toward high-throughput assays and lab-on-a-chip applications. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2006; 22:7286-95. [PMID: 16893228 DOI: 10.1021/la060854i] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Biological molecular motors that are constrained so that function is effectively limited to predefined nanosized tracks may be used as molecular shuttles in nanotechnological applications. For these applications and in high-throughput functional assays (e.g., drug screening), it is important that the motors propel their cytoskeletal filaments unidirectionally along the tracks with a minimal number of escape events. We here analyze the requirements for achieving this for actin filaments that are propelled by myosin II motor fragments (heavy meromyosin; HMM). First, we tested the guidance of HMM-propelled actin filaments along chemically defined borders. Here, trimethylchlorosilane (TMCS)-derivatized areas with high-quality HMM function were surrounded by SiO(2) domains where HMM did not bind actin. Guidance along the TMCS-SiO(2) border was almost 100% for filament approach angles between 0 and 20 degrees but only about 10% at approach angles near 90 degrees . A model (Clemmens, J.; Hess, H.; Lipscomb, R.; Hanein, Y.; Bohringer, K. F.; Matzke, C. M.; Bachand, G. D.; Bunker, B. C.; Vogel, V. Langmuir 2003, 19, 10967-10974) accounted for essential aspects of the data and also correctly predicted a more efficient guidance of actin filaments than previously shown for kinesin-propelled microtubules. Despite the efficient guidance at low approach angles, nanosized (<700 nm wide) TMCS tracks surrounded by SiO(2) were not effective in guiding actin filaments. Neither was there complete guidance along nanosized tracks that were surrounded by topographical barriers (walls and roof partially covering the track) unless there was also chemically based selectivity between the tracks and surroundings. In the latter case, with dually defined tracks, there was close to 100% guidance. A combined experimental and theoretical analysis, using tracks of the latter type, suggested that a track width of less than about 200-300 nm is sufficient at a high HMM surface density to achieve unidirectional sliding of actin filaments. In accord with these results, we demonstrate the long-term trapping of actin filaments on a closed-loop track (width < 250 nm). The results are discussed in relation to lab-on-a-chip applications and nanotechnology-assisted assays of actomyosin function.
Collapse
Affiliation(s)
- Mark Sundberg
- Department of Chemistry and Biomedical Sciences, University of Kalmar, SE-39182 Kalmar, Sweden
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Sundberg M, Balaz M, Bunk R, Rosengren-Holmberg JP, Montelius L, Nicholls IA, Omling P, Tågerud S, Månsson A. Selective spatial localization of actomyosin motor function by chemical surface patterning. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2006; 22:7302-12. [PMID: 16893230 DOI: 10.1021/la060365i] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
We have previously described the efficient guidance and unidirectional sliding of actin filaments along nanosized tracks with adsorbed heavy meromyosin (HMM; myosin II motor fragment). In those experiments, the tracks were functionalized with trimethylchlorosilane (TMCS) by chemical vapor deposition (CVD) and surrounded by hydrophilic areas. Here we first show, using in vitro motility assays on nonpatterned and micropatterned surfaces, that the quality of HMM function on CVD-TMCS is equivalent to that on standard nitrocellulose substrates. We further examine the influences of physical properties of different surfaces (glass, SiO(2), and TMCS) and chemical properties of the buffer solution on motility. With the presence of methylcellulose in the assay solution, there was HMM-induced actin filament sliding on both glass/SiO(2) and on TMCS, but the velocity was higher on TMCS. This difference in velocity increased with decreasing contact angles of the glass and SiO(2) surfaces in the range of 20-67 degrees (advancing contact angles for water droplets). The corresponding contact angle of CVD-TMCS was 81 degrees. In the absence of methylcellulose, there was high-quality motility on TMCS but no motility on glass/SiO(2). This observation was independent of the contact angle of the glass/SiO(2) surfaces and of HMM incubation concentrations (30-150 microg mL(-)(1)) and ionic strengths of the assay solution (20-50 mM). Complete motility selectivity between TMCS and SiO(2) was observed for both nonpatterned and for micro- and nanopatterned surfaces. Spectrophotometric analysis of HMM depletion during incubation, K/EDTA ATPase measurements, and total internal reflection fluorescence spectroscopy of HMM binding showed only minor differences in HMM surface densities between TMCS and SiO(2)/glass. Thus, the motility contrast between the two surface chemistries seems to be attributable to different modes of HMM binding with the hindrance of actin binding on SiO(2)/glass.
Collapse
Affiliation(s)
- Mark Sundberg
- Department of Chemistry and Biomedical Sciences, University of Kalmar, SE-39182 Kalmar, Sweden
| | | | | | | | | | | | | | | | | |
Collapse
|