1
|
Abad Tan S, Zoidl G, Ghafar-Zadeh E. A Multidisciplinary Approach Toward High Throughput Label-Free Cytotoxicity Monitoring of Superparamagnetic Iron Oxide Nanoparticles. Bioengineering (Basel) 2019; 6:E52. [PMID: 31185664 PMCID: PMC6631604 DOI: 10.3390/bioengineering6020052] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2019] [Revised: 05/24/2019] [Accepted: 06/05/2019] [Indexed: 12/12/2022] Open
Abstract
Abstract: This paper focuses on cytotoxicity examination of superparamagnetic iron oxide nanoparticles (SPIONs) using different methods, including impedance spectroscopy. Recent advances of SPIONs for clinical and research applications have triggered the need to understand their effects in cells. Despite the great advances in adapting various biological and chemical methods to assess in-vitro toxicity of SPIONs, less attention has been paid on the development of a high throughput label-free screening platform to study the interaction between the cells and nanoparticles including SPIONs. In this paper, we have taken the first step toward this goal by proposing a label-free impedimetric method for monitoring living cells treated with SPIONs. We demonstrate the effect of SPIONs on the adhesion, growth, proliferation, and viability of neuroblastoma 2A (N2a) cells using impedance spectroscopy as a label-free method, along with other standard microscopic and cell viability testing methods as control methods. Our results have shown a decreased viability of the cells as the concentration of SPIONs increases with percentages of 59%, 47%, and 40% for 100 µg/mL (C4), 200 µg/mL (C5), 300 µg/mL (C6), respectively. Although all SPIONs concentrations have allowed the growth of cells within 72 hours, C4, C5, and C6 showed slower growth compared to the control (C1). The growth and proliferation of N2a cells are faster in the absence or low concentration of SPIONS. The percent coefficient of variation (% CV) was used to compare cell concentrations obtained by TBDE assay and a Scepter cell counter. Results also showed that the lower the SPIONs concentration, the lower the impedance is expected to be in the sensing electrodes without the cells. Meanwhile, the variation of surface area (∆S) was affected by the concentration of SPIONs. It was observed that the double layer capacitance was almost constant because of the higher attachment of cells, the lower surface area coated by SPIONs. In conclusion, impedance changes of electrodes exposed to the mixture of cells and SPIONs offer a wide dynamic range (>1 MΩ using Electric Cell-substrate Impedance electrodes) suitable for cytotoxicity studies. Based on impedance based, viability testing and microscopic methods' results, SPIONs concentrations higher than 100 ug/mL and 300 ug/mL cause minor and major effects, respectively. We propose that a high throughput impedance-based label-free platform provides great advantages for studying SPIONs in a cell-based context, opening a window of opportunity to design and test the next generation of SPIONs with reduced toxicity for biomedical or medical applications.
Collapse
Affiliation(s)
- Sonia Abad Tan
- Biologically Inspired Sensors and Actuators Laboratory, Lassonde School of Engineering, York University, Ontario, Toronto M3J 1P3, Canada.
- Department of Biology, York University, Ontario, Toronto M3J 1P3, Canada.
| | - Georg Zoidl
- Department of Biology, York University, Ontario, Toronto M3J 1P3, Canada.
- Department of Psychology, York University, Ontario, Toronto M3J 1P3, Canada.
| | - Ebrahim Ghafar-Zadeh
- Biologically Inspired Sensors and Actuators Laboratory, Lassonde School of Engineering, York University, Ontario, Toronto M3J 1P3, Canada.
- Department of Biology, York University, Ontario, Toronto M3J 1P3, Canada.
- Department of Electrical Engineering and Computer Science, York University, Ontario, Toronto M3J 1P3, Canada.
| |
Collapse
|
2
|
Fluorescence-based assay as a new screening tool for toxic chemicals. Sci Rep 2016; 6:33922. [PMID: 27653274 PMCID: PMC5031998 DOI: 10.1038/srep33922] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2016] [Accepted: 08/23/2016] [Indexed: 01/08/2023] Open
Abstract
Our study involves development of fluorescent cell-based diagnostic assay as a new approach in high-throughput screening method. This highly sensitive optical assay operates similarly to e-noses and e-tongues which combine semi-specific sensors and multivariate data analysis for monitoring biochemical processes. The optical assay consists of a mixture of environmental-sensitive fluorescent dyes and human skin cells that generate fluorescence spectra patterns distinctive for particular physico-chemical and physiological conditions. Using chemometric techniques the optical signal is processed providing qualitative information about analytical characteristics of the samples. This integrated approach has been successfully applied (with sensitivity of 93% and specificity of 97%) in assessing whether particular chemical agents are irritating or not for human skin. It has several advantages compared with traditional biochemical or biological assays and can impact the new way of high-throughput screening and understanding cell activity. It also can provide reliable and reproducible method for assessing a risk of exposing people to different harmful substances, identification active compounds in toxicity screening and safety assessment of drugs, cosmetic or their specific ingredients.
Collapse
|
3
|
Bashir S, Solvas XCI, Bashir M, Rees JM, Zimmerman WBJ. Dynamic wetting in microfluidic droplet formation. BIOCHIP JOURNAL 2014. [DOI: 10.1007/s13206-014-8207-y] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
4
|
Fritzsche M, Fritzsche J, Tegenfeldt JO, Mandenius CF. A highly UV-transparent fused silica biochip for sensitive hepatotoxicity testing by autofluorescence. BIOCHIP JOURNAL 2014. [DOI: 10.1007/s13206-014-8206-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
5
|
Metabolic flux analysis gives an insight on verapamil induced changes in central metabolism of HL-1 cells. J Biotechnol 2011; 155:299-307. [PMID: 21824500 DOI: 10.1016/j.jbiotec.2011.07.028] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2011] [Revised: 07/11/2011] [Accepted: 07/25/2011] [Indexed: 01/28/2023]
Abstract
Verapamil has been shown to inhibit glucose transport in several cell types. However, the consequences of this inhibition on central metabolism are not well known. In this study we focused on verapamil induced changes in metabolic fluxes in a murine atrial cell line (HL-1 cells). These cells were adapted to serum free conditions and incubated with 4 μM verapamil and [U-¹³C₅] glutamine. Specific extracellular metabolite uptake/production rates together with mass isotopomer fractions in alanine and glutamate were implemented into a metabolic network model to calculate metabolic flux distributions in the central metabolism. Verapamil decreased specific glucose consumption rate and glycolytic activity by 60%. Although the HL-1 cells show Warburg effect with high lactate production, verapamil treated cells completely stopped lactate production after 24 h while maintaining growth comparable to the untreated cells. Calculated fluxes in TCA cycle reactions as well as NADH/FADH₂ production rates were similar in both treated and untreated cells. This was confirmed by measurement of cell respiration. Reduction of lactate production seems to be the consequence of decreased glucose uptake due to verapamil. In case of tumors, this may have two fold effects; firstly depriving cancer cells of substrate for anaerobic glycolysis on which their growth is dependent; secondly changing pH of the tumor environment, as lactate secretion keeps the pH acidic and facilitates tumor growth. The results shown in this study may partly explain recent observations in which verapamil has been proposed to be a potential anticancer agent. Moreover, in biotechnological production using cell lines, verapamil may be used to reduce glucose uptake and lactate secretion thereby increasing protein production without introduction of genetic modifications and application of more complicated fed-batch processes.
Collapse
|
6
|
Mandenius CF, Andersson TB, Alves PM, Batzl-Hartmann C, Björquist P, Carrondo MJ, Chesne C, Coecke S, Edsbagge J, Fredriksson JM, Gerlach JC, Heinzle E, Ingelman-Sundberg M, Johansson I, Küppers-Munther B, Müller-Vieira U, Noor F, Zeilinger K. Toward Preclinical Predictive Drug Testing for Metabolism and Hepatotoxicity by Using In Vitro Models Derived from Human Embryonic Stem Cells and Human Cell Lines — A Report on the Vitrocellomics EU-project. Altern Lab Anim 2011; 39:147-71. [DOI: 10.1177/026119291103900210] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Drug-induced liver injury is a common reason for drug attrition in late clinical phases, and even for post-launch withdrawals. As a consequence, there is a broad consensus in the pharmaceutical industry, and within regulatory authorities, that a significant improvement of the current in vitro test methodologies for accurate assessment and prediction of such adverse effects is needed. For this purpose, appropriate in vivo-like hepatic in vitro models are necessary, in addition to novel sources of human hepatocytes. In this report, we describe recent and ongoing research toward the use of human embryonic stem cell (hESC)-derived hepatic cells, in conjunction with new and improved test methods, for evaluating drug metabolism and hepatotoxicity. Recent progress on the directed differentiation of human embryonic stem cells to the functional hepatic phenotype is reported, as well as the development and adaptation of bioreactors and toxicity assay technologies for the testing of hepatic cells. The aim of achieving a testing platform for metabolism and hepatotoxicity assessment, based on hESC-derived hepatic cells, has advanced markedly in the last 2–3 years. However, great challenges still remain, before such new test systems could be routinely used by the industry. In particular, we give an overview of results from the Vitrocellomics project (EU Framework 6) and discuss these in relation to the current state-of-the-art and the remaining difficulties, with suggestions on how to proceed before such in vitro systems can be implemented in industrial discovery and development settings and in regulatory acceptance.
Collapse
Affiliation(s)
| | - Tommy B. Andersson
- Karolinska Institute, Department of Physiology and Pharmacology, Stockholm, Sweden
- Development DMPK & Bioanalysis, AstraZeneca R&D, Mölndal, Sweden
| | | | | | | | | | | | - Sandra Coecke
- ECVAM, Institute for Health and Consumer Protection, European Commission Joint Research Centre, Ispra, Italy
| | | | | | - Jörg C. Gerlach
- Experimental Surgery, Charité Universitätsmedizin, Berlin, Germany
| | - Elmar Heinzle
- Biochemical Engineering, Saarland University, Saarbrücken, Germany
| | | | - Inger Johansson
- Karolinska Institute, Department of Physiology and Pharmacology, Stockholm, Sweden
| | | | | | - Fozia Noor
- Biochemical Engineering, Saarland University, Saarbrücken, Germany
| | - Katrin Zeilinger
- Experimental Surgery, Charité Universitätsmedizin, Berlin, Germany
| |
Collapse
|
7
|
Li W, Knoll T, Thielecke H. On-chip integrated lensless microscopy module for optical monitoring of adherent growing mammalian cells. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2011; 2010:1012-5. [PMID: 21096993 DOI: 10.1109/iembs.2010.5627771] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Lab-on-a-chip systems are increasingly applied in cell-based assays for toxicology and drug testing. In this paper, an on-chip integrated lensless microscopy module using a direct projection method for optical monitoring of the shadow images of adherent growing mammalian cells is presented. The biological cells are conserved and interfaced by a microfabricated cavity chip with a 1 microm thick silicon nitride (Si(3)N(4)) substrate onto the surface of a 5 megapixel CMOS image sensor with 2.2 microm pixel size. The optical resolution of the assembly is estimated by the contact/proximate printing theory from optical lithography. Further characterization is made by imaging microbeads in chips with the Si(3)N(4)-membrane as well as in cavity chips with membranes made from dry film resist (DFR, thickness 20, 40 and 60 microm). The module represents a 3 × optical microscope for cell morphology imaging. The function is demonstrated by the growth monitoring of L929 cells cultured in cavity chips with Si(3)N(4) substrate for 2 days and by checking the colorimetric staining of cells with a compromised membrane.
Collapse
Affiliation(s)
- Wei Li
- Fraunhofer Institute for Biomedical Engineering, Department of Biohybrid Systems, Germany
| | | | | |
Collapse
|
8
|
Mandenius CF, Steel D, Noor F, Meyer T, Heinzle E, Asp J, Arain S, Kraushaar U, Bremer S, Class R, Sartipy P. Cardiotoxicity testing using pluripotent stem cell-derived human cardiomyocytes and state-of-the-art bioanalytics: a review. J Appl Toxicol 2011; 31:191-205. [DOI: 10.1002/jat.1663] [Citation(s) in RCA: 63] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2010] [Revised: 12/30/2010] [Accepted: 12/31/2010] [Indexed: 12/13/2022]
Affiliation(s)
| | | | - Fozia Noor
- Biochemical Engineering; Saarland University; Saarbruecken; Germany
| | | | - Elmar Heinzle
- Biochemical Engineering; Saarland University; Saarbruecken; Germany
| | - Julia Asp
- Department of Clinical Chemistry and Transfusion Medicine; Institute of Biomedicine; the Sahlgrenska Academy; University of Gothenburg; Göteborg; Sweden
| | | | - Udo Kraushaar
- Natural and Medical Sciences Institute at the University of Tübingen; Germany
| | - Susanne Bremer
- ECVAM; Institute for Health and Consumer Protection (IHCP); European Commission Joint Research Center; Ispra; Italy
| | | | | |
Collapse
|
9
|
Cardiotoxicity of kinase inhibitors: the prediction and translation of preclinical models to clinical outcomes. Nat Rev Drug Discov 2011; 10:111-26. [PMID: 21283106 DOI: 10.1038/nrd3252] [Citation(s) in RCA: 258] [Impact Index Per Article: 19.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
10
|
Mitik-Dineva N, Wang J, Truong VK, Stoddart PR, Alexander MR, Albutt DJ, Fluke C, Crawford RJ, Ivanova EP. Bacterial attachment on optical fibre surfaces. BIOFOULING 2010; 26:461-471. [PMID: 20358429 DOI: 10.1080/08927011003753399] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Optical fibres have received considerable attention as high-density sensor arrays suitable for both in vitro and in vivo measurements of biomolecules and biological processes in living organisms and/or nano-environments. The fibre surface was chemically modified by exposure to a selective etchant that preferentially erodes the fibre cores relative to the surrounding cladding material, thus producing a regular pattern of cylindrical wells of approximately 2.5 mum in diameter and 2.5 mum deep. The surface hydrophobicity of the etched and non-etched optical fibres was analysed using the sessile pico-drop method. The surface topography was characterised by atomic force microscopy (AFM), while the surface chemistry was probed by time-of-flight secondary ion mass spectrometry (ToF-SIMS). Six taxonomically different bacterial strains showed a consistent preference for attachment to the nano-scale smoother (R(q) = 273 nm), non-etched fibre surfaces (water contact angle, theta = 106 degrees +/- 4 degrees). In comparison, the surfaces of the etched optical fibres (water contact angle, theta = 96 degrees +/- 10 degrees) were not found to be amenable to bacterial attachment. Bacterial attachment on the non-etched optical fibre substrata varied among different strains.
Collapse
Affiliation(s)
- N Mitik-Dineva
- Faculty of Life and Social Sciences, Swinburne University of Technology, Hawthorn, Victoria, Australia
| | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Fritzsche M, Mandenius CF. Fluorescent cell-based sensing approaches for toxicity testing. Anal Bioanal Chem 2010; 398:181-91. [DOI: 10.1007/s00216-010-3651-6] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2010] [Accepted: 03/11/2010] [Indexed: 12/01/2022]
|
12
|
Auld D, Simeonov A, Thomas C. Literature Search and Review. Assay Drug Dev Technol 2009. [DOI: 10.1089/adt.2009.9995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Affiliation(s)
- Doug Auld
- National Institutes of Health, Bethesda, Maryland
| | | | - Craig Thomas
- National Institutes of Health, Bethesda, Maryland
| |
Collapse
|