1
|
Am A, Faccio ME, Pinvidic M, Reygue E, Doan BT, Lescot C, Trapiella Alfonso L, d'Orlyé F, Varenne A. A methodological approach by capillary electrophoresis coupled to mass spectrometry via electrospray interface for the characterization of short synthetic peptides towards the conception of self-assembled nanotheranostic agents. J Chromatogr A 2024; 1713:464496. [PMID: 37976903 DOI: 10.1016/j.chroma.2023.464496] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Revised: 10/27/2023] [Accepted: 11/06/2023] [Indexed: 11/19/2023]
Abstract
Nanostructures formed by the self-assembling peptide building blocks are attractive materials for the design of theranostic objects due to their intrinsic biocompatibility, accessible surface chemistry as well as cavitary morphology. Short peptide synthesis and modification are straightforward and give access to a great diversity of sequences, making them very versatile building blocks allowing for the design of thoroughly controlled self-assembled nanostructures. In this work, we developed a new CE-DAD-ESI-MS method to characterize short synthetic amphiphilic peptides in terms of exact sequence and purity level in the low 0.1 mg.mL-1 range, without sample treatment. This study was conducted using a model sequence, described to have pH sensitive self-assembling property. Peptide samples obtained from different synthesis processes (batch or flow, purified or not) were thus separated by capillary zone electrophoresis (CZE). The associated dual UV and MS detection mode allowed to evidence the exact sequence together with the presence of impurities, identified as truncated or non-deprotected sequences, and to quantify their relative proportion in the peptide mixture. Our results demonstrate that the developed CE-DAD-ESI-MS method could be directly applied to the characterization of crude synthetic peptide products, in parallel with the optimization of peptide synthetic pathway to obtain controlled sequences with high synthetic yield and purity, which is crucial for further design of robust peptide based self-assembled nanoarchitectures.
Collapse
Affiliation(s)
- Alice Am
- Institute of Chemistry for Life & Health Sciences (iCLeHS), Chimie ParisTech, PSL University, CNRS 8060, Paris 75005, France
| | - Marta Elisa Faccio
- Institute of Chemistry for Life & Health Sciences (iCLeHS), Chimie ParisTech, PSL University, CNRS 8060, Paris 75005, France
| | - Marie Pinvidic
- Institute of Chemistry for Life & Health Sciences (iCLeHS), Chimie ParisTech, PSL University, CNRS 8060, Paris 75005, France
| | - Eva Reygue
- Institute of Chemistry for Life & Health Sciences (iCLeHS), Chimie ParisTech, PSL University, CNRS 8060, Paris 75005, France
| | - Bich-Thuy Doan
- Institute of Chemistry for Life & Health Sciences (iCLeHS), Chimie ParisTech, PSL University, CNRS 8060, Paris 75005, France
| | - Camille Lescot
- Institute of Chemistry for Life & Health Sciences (iCLeHS), Chimie ParisTech, PSL University, CNRS 8060, Paris 75005, France
| | - Laura Trapiella Alfonso
- Institute of Chemistry for Life & Health Sciences (iCLeHS), Chimie ParisTech, PSL University, CNRS 8060, Paris 75005, France
| | - Fanny d'Orlyé
- Institute of Chemistry for Life & Health Sciences (iCLeHS), Chimie ParisTech, PSL University, CNRS 8060, Paris 75005, France.
| | - Anne Varenne
- Institute of Chemistry for Life & Health Sciences (iCLeHS), Chimie ParisTech, PSL University, CNRS 8060, Paris 75005, France.
| |
Collapse
|
2
|
Synthesis, Characterization and Evaluation of Peptide Nanostructures for Biomedical Applications. Molecules 2021; 26:molecules26154587. [PMID: 34361740 PMCID: PMC8348434 DOI: 10.3390/molecules26154587] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Revised: 07/04/2021] [Accepted: 07/17/2021] [Indexed: 12/19/2022] Open
Abstract
There is a challenging need for the development of new alternative nanostructures that can allow the coupling and/or encapsulation of therapeutic/diagnostic molecules while reducing their toxicity and improving their circulation and in-vivo targeting. Among the new materials using natural building blocks, peptides have attracted significant interest because of their simple structure, relative chemical and physical stability, diversity of sequences and forms, their easy functionalization with (bio)molecules and the possibility of synthesizing them in large quantities. A number of them have the ability to self-assemble into nanotubes, -spheres, -vesicles or -rods under mild conditions, which opens up new applications in biology and nanomedicine due to their intrinsic biocompatibility and biodegradability as well as their surface chemical reactivity via amino- and carboxyl groups. In order to obtain nanostructures suitable for biomedical applications, the structure, size, shape and surface chemistry of these nanoplatforms must be optimized. These properties depend directly on the nature and sequence of the amino acids that constitute them. It is therefore essential to control the order in which the amino acids are introduced during the synthesis of short peptide chains and to evaluate their in-vitro and in-vivo physico-chemical properties before testing them for biomedical applications. This review therefore focuses on the synthesis, functionalization and characterization of peptide sequences that can self-assemble to form nanostructures. The synthesis in batch or with new continuous flow and microflow techniques will be described and compared in terms of amino acids sequence, purification processes, functionalization or encapsulation of targeting ligands, imaging probes as well as therapeutic molecules. Their chemical and biological characterization will be presented to evaluate their purity, toxicity, biocompatibility and biodistribution, and some therapeutic properties in vitro and in vivo. Finally, their main applications in the biomedical field will be presented so as to highlight their importance and advantages over classical nanostructures.
Collapse
|
3
|
Cortez-Díaz MD, d'Orlyé F, Varenne A. Characterization of New Cyclic D,L-α-Alternate Amino Acid Peptides by Capillary Electrophoresis Coupled to Electrospray Ionization Mass Spectrometry. Methods Mol Biol 2019; 1855:315-326. [PMID: 30426428 DOI: 10.1007/978-1-4939-8793-1_27] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
The self-assembly of peptide nanotubes (PNTs) depends on the structure and chemistry of cyclic peptide (CP) monomers, impacting on their properties, which makes the choice of their monomers and their characterization a high challenge. For this purpose, we developed for the first time a capillary electrophoresis coupled to electrospray ionization mass spectrometry (CE-ESI-MS) methodology and characterized a set of eight original CP sequences of 8, 10, and 12 D,L-α-alternate amino acids with a controlled internal diameter (from 7 to 13 Å) and various properties (diameter, global surface charge, hydrophobicity). This new CE-ESI-MS methodology allows verifying the structure, the purity, as well as the stability (when stored during several months) of interesting potential precursors for PNTs that could be employed as nanoplatforms in diagnostics or pseudo sieving tools for separation purposes.
Collapse
Affiliation(s)
- María Dámaris Cortez-Díaz
- Chimie ParisTech PSL, Ecole Nationale Supérieure de Chimie, Unité de Technologies Chimiques et Biologiques pour la Santé, Paris, France
- CNRS, Unité de Technologies Chimiques et Biologiques pour la Santé UMR 8258, Paris, France
- Université Paris Descartes, Unité de Technologies Chimiques et Biologiques pour la Santé, Paris, France
- INSERM, Unité de Technologies Chimiques et Biologiques pour la Santé (N°1022), Paris, France
- Departamento de Quimica, Universidad de Guanajuato, Guanajuato, Mexico
| | - Fanny d'Orlyé
- Chimie ParisTech PSL, Ecole Nationale Supérieure de Chimie, Unité de Technologies Chimiques et Biologiques pour la Santé, Paris, France
- CNRS, Unité de Technologies Chimiques et Biologiques pour la Santé UMR 8258, Paris, France
- Université Paris Descartes, Unité de Technologies Chimiques et Biologiques pour la Santé, Paris, France
- INSERM, Unité de Technologies Chimiques et Biologiques pour la Santé (N°1022), Paris, France
| | - Anne Varenne
- Chimie ParisTech PSL, Ecole Nationale Supérieure de Chimie, Unité de Technologies Chimiques et Biologiques pour la Santé, Paris, France.
- CNRS, Unité de Technologies Chimiques et Biologiques pour la Santé UMR 8258, Paris, France.
- Université Paris Descartes, Unité de Technologies Chimiques et Biologiques pour la Santé, Paris, France.
- INSERM, Unité de Technologies Chimiques et Biologiques pour la Santé (N°1022), Paris, France.
| |
Collapse
|
4
|
Stolz A, Jooß K, Höcker O, Römer J, Schlecht J, Neusüß C. Recent advances in capillary electrophoresis-mass spectrometry: Instrumentation, methodology and applications. Electrophoresis 2018; 40:79-112. [PMID: 30260009 DOI: 10.1002/elps.201800331] [Citation(s) in RCA: 109] [Impact Index Per Article: 18.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2018] [Revised: 09/06/2018] [Accepted: 09/07/2018] [Indexed: 12/14/2022]
Abstract
Capillary electrophoresis (CE) offers fast and high-resolution separation of charged analytes from small injection volumes. Coupled to mass spectrometry (MS), it represents a powerful analytical technique providing (exact) mass information and enables molecular characterization based on fragmentation. Although hyphenation of CE and MS is not straightforward, much emphasis has been placed on enabling efficient ionization and user-friendly coupling. Though several interfaces are now commercially available, research on more efficient and robust interfacing with nano-electrospray ionization (ESI), matrix-assisted laser desorption/ionization (MALDI) and inductively coupled plasma mass spectrometry (ICP) continues with considerable results. At the same time, CE-MS has been used in many fields, predominantly for the analysis of proteins, peptides and metabolites. This review belongs to a series of regularly published articles, summarizing 248 articles covering the time between June 2016 and May 2018. Latest developments on hyphenation of CE with MS as well as instrumental developments such as two-dimensional separation systems with MS detection are mentioned. Furthermore, applications of various CE-modes including capillary zone electrophoresis (CZE), nonaqueous capillary electrophoresis (NACE), capillary gel electrophoresis (CGE) and capillary isoelectric focusing (CIEF) coupled to MS in biological, pharmaceutical and environmental research are summarized.
Collapse
Affiliation(s)
| | - Kevin Jooß
- Faculty of Chemistry, Aalen University, Aalen, Germany.,Research Unit Analytical BioGeoChemistry, Helmholtz Zentrum München, Neuherberg, Germany
| | - Oliver Höcker
- Faculty of Chemistry, Aalen University, Aalen, Germany.,Instrumental Analytical Chemistry, University of Duisburg-Essen, Essen, Germany
| | - Jennifer Römer
- Faculty of Chemistry, Aalen University, Aalen, Germany.,Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, Regensburg, Germany
| | - Johannes Schlecht
- Faculty of Chemistry, Aalen University, Aalen, Germany.,Department of Pharmaceutical/Medicinal Chemistry, Friedrich Schiller University, Jena, Germany
| | | |
Collapse
|
5
|
Kašička V. Recent developments in capillary and microchip electroseparations of peptides (2015-mid 2017). Electrophoresis 2017; 39:209-234. [PMID: 28836681 DOI: 10.1002/elps.201700295] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2017] [Revised: 08/15/2017] [Accepted: 08/16/2017] [Indexed: 12/17/2022]
Abstract
The review brings a comprehensive overview of recent developments and applications of high performance capillary and microchip electroseparation methods (zone electrophoresis, isotachophoresis, isoelectric focusing, affinity electrophoresis, electrokinetic chromatography, and electrochromatography) to analysis, microscale isolation, purification, and physicochemical and biochemical characterization of peptides in the years 2015, 2016, and ca. up to the middle of 2017. Advances in the investigation of electromigration properties of peptides and in the methodology of their analysis (sample preseparation, preconcentration and derivatization, adsorption suppression and EOF control, and detection) are described. New developments in particular CE and CEC methods are presented and several types of their applications to peptide analysis are reported: qualitative and quantitative analysis, determination in complex (bio)matrices, monitoring of chemical and enzymatical reactions and physical changes, amino acid, sequence and chiral analysis, and peptide mapping of proteins. Some micropreparative peptide separations are shown and capabilities of CE and CEC methods to provide important physicochemical characteristics of peptides are demonstrated.
Collapse
Affiliation(s)
- Václav Kašička
- Institute of Organic Chemistry and Biochemistry, The Czech Academy of Sciences, Prague, Czech Republic
| |
Collapse
|