1
|
Arman S, Tilley RD, Gooding JJ. A review of electrochemical impedance as a tool for examining cell biology and subcellular mechanisms: merits, limits, and future prospects. Analyst 2024; 149:269-289. [PMID: 38015145 DOI: 10.1039/d3an01423a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2023]
Abstract
Herein the development of cellular impedance biosensors, electrochemical impedance spectroscopy, and the general principles and terms associated with the cell-electrode interface is reviewed. This family of techniques provides quantitative and sensitive information into cell responses to stimuli in real-time with high temporal resolution. The applications of cell-based impedance biosensors as a readout in cell biology is illustrated with a diverse range of examples. The current state of the field, its limitations, the possible available solutions, and the potential benefits of developing biosensors are discussed.
Collapse
Affiliation(s)
- Seyedyousef Arman
- School of Chemistry, The University of New South Wales, Sydney, New South Wales 2052, Australia.
- Australia Centre for Nanomedicine, The University of New South Wales, Sydney, New South Wales 2052, Australia
| | - Richard D Tilley
- School of Chemistry, The University of New South Wales, Sydney, New South Wales 2052, Australia.
- Electron Microscope Unit, Mark Wainwright Analytical Centre, The University of New South Wales, Sydney, New South Wales 2052, Australia
| | - J Justin Gooding
- School of Chemistry, The University of New South Wales, Sydney, New South Wales 2052, Australia.
- Australia Centre for Nanomedicine, The University of New South Wales, Sydney, New South Wales 2052, Australia
| |
Collapse
|
2
|
Angeline N, Suhito IR, Kim CH, Hong GP, Park CG, Bhang SH, Luo Z, Kim TH. A fibronectin-coated gold nanostructure composite for electrochemical detection of effects of curcumin-carrying nanoliposomes on human stomach cancer cells. Analyst 2019; 145:675-684. [PMID: 31803868 DOI: 10.1039/c9an01553a] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Curcumin, which is produced by the medicinal herbaceous plant Curcuma longa, has been widely investigated for use as a potential anticancer drug. In this study, the potential toxicity of curcumin-carrying nanoliposomes (curcumin-NLC) toward human stomach cancer cells (MKN-28) was investigated using a new cell-based electrochemical sensing platform. To satisfy both biocompatibility and electroconductivity of the electrodes, the density of the gold nanostructure and the coating conditions of extracellular matrix proteins (fibronectin and collagen) were optimized. The developed platform enabled the successful adhesion and long-term growth of stomach cancer cells on the chip surface, allowing label-free and real-time monitoring of cell viability in a quantitative manner. According to the electrochemical results, both bare curcumin and curcumin-NLC showed toxicity toward MKN-28 cells in the concentration range of 10-100 μM, which was consistent with the results obtained from a conventional colorimetric method (CCK-8). Remarkably, at a low concentration range (<50 μM), this electrochemical platform determined the decrease in cell viability to be approximately 22.8%, 33.9% and 53.1% in the presence of 10, 30, and 50 μM of curcumin-NLC, respectively, compared with the 1.3%, 18.5%, and 28.1% determined by CCK-8, making it 1.7-2 times more sensitive than the conventional colorimetric assay. Hence, it can be concluded that the newly developed fibronectin-coated electroconductive platform is highly promising as an electrochemical detection tool for the sensitive and precise assessment of the anticancer effects of various food-derived compounds with low toxicity.
Collapse
Affiliation(s)
- Novi Angeline
- School of Integrative Engineering, Chung-Ang University, Seoul 06974, Republic of Korea.
| | - Intan Rosalina Suhito
- School of Integrative Engineering, Chung-Ang University, Seoul 06974, Republic of Korea.
| | - Cheol-Hwi Kim
- School of Integrative Engineering, Chung-Ang University, Seoul 06974, Republic of Korea.
| | - Geun-Pyo Hong
- Department of Food Science and Biotechnology, Sejong University, Seoul 05006, Republic of Korea
| | - Chun Gwon Park
- Department of Biomedical Engineering, Sungkyunkwan University Institute for Convergence, Sungkyunkwan University, Suwon 16419, Republic of Korea
| | - Suk Ho Bhang
- School of Chemical Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea
| | - Zhengtang Luo
- Department of Chemical and Biological Engineering, Hong Kong University of Science and Technology, Kowloon 999077, Hong Kong, China
| | - Tae-Hyung Kim
- School of Integrative Engineering, Chung-Ang University, Seoul 06974, Republic of Korea. and Integrative Research Center for Two-Dimensional Functional Materials, Institute of Interdisciplinary Convergence Research, Chung-Ang University, Seoul 06974, Republic of Korea
| |
Collapse
|
3
|
Liu Q, Wu C, Cai H, Hu N, Zhou J, Wang P. Cell-based biosensors and their application in biomedicine. Chem Rev 2014; 114:6423-61. [PMID: 24905074 DOI: 10.1021/cr2003129] [Citation(s) in RCA: 185] [Impact Index Per Article: 18.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Affiliation(s)
- Qingjun Liu
- Biosensor National Special Laboratory, Key Laboratory of Biomedical Engineering of the Ministry of Education, Department of Biomedical Engineering, Zhejiang University , Hangzhou 310027, China
| | | | | | | | | | | |
Collapse
|
4
|
Microfabricated electrochemical cell-based biosensors for analysis of living cells in vitro. BIOSENSORS-BASEL 2012; 2:127-70. [PMID: 25585708 PMCID: PMC4263572 DOI: 10.3390/bios2020127] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/02/2012] [Revised: 04/02/2012] [Accepted: 04/19/2012] [Indexed: 01/03/2023]
Abstract
Cellular biochemical parameters can be used to reveal the physiological and functional information of various cells. Due to demonstrated high accuracy and non-invasiveness, electrochemical detection methods have been used for cell-based investigation. When combined with improved biosensor design and advanced measurement systems, the on-line biochemical analysis of living cells in vitro has been applied for biological mechanism study, drug screening and even environmental monitoring. In recent decades, new types of miniaturized electrochemical biosensor are emerging with the development of microfabrication technology. This review aims to give an overview of the microfabricated electrochemical cell-based biosensors, such as microelectrode arrays (MEA), the electric cell-substrate impedance sensing (ECIS) technique, and the light addressable potentiometric sensor (LAPS). The details in their working principles, measurement systems, and applications in cell monitoring are covered. Driven by the need for high throughput and multi-parameter detection proposed by biomedicine, the development trends of electrochemical cell-based biosensors are also introduced, including newly developed integrated biosensors, and the application of nanotechnology and microfluidic technology.
Collapse
|
5
|
Lin CY, Teng NC, Hsieh SC, Lin YS, Chang WJ, Hsiao SY, Huang HS, Huang HM. Real-time detection of β1 integrin expression on MG-63 cells using electrochemical impedance spectroscopy. Biosens Bioelectron 2011; 28:221-6. [PMID: 21816605 DOI: 10.1016/j.bios.2011.07.022] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2011] [Revised: 07/11/2011] [Accepted: 07/11/2011] [Indexed: 12/01/2022]
Abstract
Beta 1 integrin is a membrane protein responsible for attachment and migration of osteosarcoma cells. In this study, expression of β1 integrin on MG-63 cells, a human osteogenic sarcoma cell line, was monitored using electrochemical impedance spectroscopy (EIS). ITO-based biochips were developed using a semiconductor technique. Differences in electric resistance (ΔR) were measured continuously when cells binding with anti-β1 integrin antibody coagulated with nano-scale gold particles. The results of the EIS system were compared with traditional immunofluorescence staining. We found that sample chambers with higher cell densities had larger ΔR values. When the cell densities increased from 5 × 10(4) cells/ml to 5 × 10(5) cells/ml, the ΔR value dose-dependently increased from 14 Ω to 37 Ω. In addition, a highly linear relationship (correlation coefficient, 0.921) was found between the ΔR values and the corresponding fluorescence intensities (p<0.05). These results suggest that electrochemical impedance spectroscopy can be a useful tool for evaluating β1 integrin expression on cell membranes.
Collapse
Affiliation(s)
- Chun-Yen Lin
- School of Dentistry, College of Oral Medicine, Taipei Medical University, 250, Wu-Hsing Street, Taipei, Taiwan
| | | | | | | | | | | | | | | |
Collapse
|
6
|
Gou HL, Zhang XB, Bao N, Xu JJ, Xia XH, Chen HY. Label-free electrical discrimination of cells at normal, apoptotic and necrotic status with a microfluidic device. J Chromatogr A 2011; 1218:5725-9. [DOI: 10.1016/j.chroma.2011.06.102] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2011] [Revised: 06/21/2011] [Accepted: 06/26/2011] [Indexed: 01/12/2023]
|
7
|
Wiertz RWF, Marani E, Rutten WLC. Neural cell-cell and cell-substrate adhesion through N-cadherin, N-CAM and L1. J Neural Eng 2011; 8:046004. [PMID: 21628769 DOI: 10.1088/1741-2560/8/4/046004] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
In this study neural (N)-cadherin, neural cell adhesion molecule (N-CAM) and L1 proteins and their antibody equivalents were covalently immobilized on a polyethylene-imine (PEI)-coated glass surface to form neuron-adhesive coatings. Impedance sensing and (supplementary) image analysis were used to monitor the effects of these CAMs. Immobilization of high concentrations of both N-cadherin protein and antibody led to good adhesion of neurons to the modified surface, better than surfaces treated with 30.0 and 100.0 µg ml(-1) N-CAM protein and antibody. L1 antibody and protein coating revealed no significant effect on neuronal cell-substrate adhesion. In a second series of combinatorial experiments, we used the same antibodies and proteins as medium-additives to inhibit cell-cell adhesion between neurons. Adhesion of neurons cultured on N-cadherin protein or antibody-modified surfaces was lowered by the addition of a soluble N-cadherin protein and antibody to the culturing medium, accelerating neuronal aggregation. The presence of a soluble N-CAM antibody or protein had no effect on the adhesion of neuronal cells on a N-cadherin protein-modified surface. On a N-cadherin antibody-coated surface, the addition of a soluble N-CAM protein led to cell death of neurons after 48 h, while a N-CAM antibody had no effect. In the presence of a soluble N-cadherin protein and antibody the aggregation of neurons was inhibited, both on N-CAM protein and N-CAM antibody-modified surfaces. Neurons cultured on immobilized antibodies were less affected by the addition of soluble CAM blockers than neurons cultured on immobilized proteins, indicating that antibody-protein bonds are more stable compared to protein-protein bonds.
Collapse
Affiliation(s)
- R W F Wiertz
- Neural and Cellular Engineering, MIRA Institute, University of Twente, Enschede, The Netherlands.
| | | | | |
Collapse
|
8
|
Abstract
Label-free biosensors for studying cell biology have finally come of age. Recent developments have advanced the biosensors from low throughput and high maintenance research tools to high throughput and low maintenance screening platforms. In parallel, the biosensors have evolved from an analytical tool solely for molecular interaction analysis to powerful platforms for studying cell biology at the whole cell level. This paper presents historical development, detection principles, and applications in cell biology of label-free biosensors. Future perspectives are also discussed.
Collapse
Affiliation(s)
- Ye Fang
- Biochemical Technologies, Science and Technology Division, Corning Inc., Corning, NY 14831, USA
| |
Collapse
|
9
|
Malleo D, Nevill JT, Lee LP, Morgan H. Continuous differential impedance spectroscopy of single cells. MICROFLUIDICS AND NANOFLUIDICS 2010; 9:191-198. [PMID: 20927185 PMCID: PMC2944380 DOI: 10.1007/s10404-009-0534-2] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2009] [Accepted: 11/11/2009] [Indexed: 05/21/2023]
Abstract
A device for continuous differential impedance analysis of single cells held by a hydrodynamic cell trapping is presented. Measurements are accomplished by recording the current from two closely-situated electrode pairs, one empty (reference) and one containing a cell. We demonstrate time-dependent measurement of single cell impedance produced in response to dynamic chemical perturbations. First, the system is used to assay the response of HeLa cells to the effects of the surfactant Tween, which reduces the impedance of the trapped cells in a concentration dependent way and is interpreted as gradual lysis of the cell membrane. Second, the effects of the bacterial pore-forming toxin, Streptolysin-O are measured: a transient exponential decay in the impedance is recorded as the cell membrane becomes increasingly permeable. The decay time constant is inversely proportional to toxin concentration (482, 150, and 30 s for 0.1, 1, and 10 kU/ml, respectively). ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s10404-009-0534-2) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Daniele Malleo
- School of Electronics and Computer Science, University of Southampton, Southampton, SO17 1BJ UK
- Oxford Gene Technology, Begbroke Science Park, Oxford, OX5 1PF UK
| | - J. Tanner Nevill
- Department of Bioengineering, Biomolecular Nanotechnology Center, Berkeley Sensor and Actuator Center, University of California, Berkeley, CA 94720 USA
- Present Address: Fluxion Biosciences, South San Francisco, CA 94080 USA
| | - Luke P. Lee
- Department of Bioengineering, Biomolecular Nanotechnology Center, Berkeley Sensor and Actuator Center, University of California, Berkeley, CA 94720 USA
| | - Hywel Morgan
- School of Electronics and Computer Science, University of Southampton, Southampton, SO17 1BJ UK
| |
Collapse
|
10
|
Spegel C, Heiskanen A, Skjolding L, Emnéus J. Chip Based Electroanalytical Systems for Cell Analysis. ELECTROANAL 2008. [DOI: 10.1002/elan.200704130] [Citation(s) in RCA: 58] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
|
11
|
Bouafsoun A, Helali S, Othmane A, Kerkeni A, Prigent AF, Jaffrézic-Renault N, Bessueille F, Léonard D, Ponsonnet L. Evaluation of Endothelial Cell Adhesion onto Different Protein/Gold Electrodes by EIS. Macromol Biosci 2007; 7:599-610. [PMID: 17477444 DOI: 10.1002/mabi.200600263] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
To study cell attachment to biomaterials, several proteins such as fibronectin, collagen IV, heparin, immunoglobulin G, and albumin have been deposited onto polystyrene adsorbed on a self-assembled monolayer (silane or thiol) on glass or gold, respectively. The different steps of this multilayer assembly have been characterized by electrochemical impedance spectroscopy (EIS). These data are compared to those of adhesion rate, viability percentage, and cytoskeleton labeling for a better understanding of the cell adhesion process to each protein. All the proteins are endothelial cell adhering biomolecules but not with the same features. A linear relationship has been established between adhesion rate and resistance of the endothelial cell/protein interface for all negatively charged proteins.
Collapse
Affiliation(s)
- Amira Bouafsoun
- Ecole Centrale de Lyon, CEGELY, UMR 5005 CNRS-Ecole Centrale de Lyon, av Guy de Collongue, 69134 Ecully Cedex, France
| | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Glahder J, Norrild B, Persson MB, Persson BRR. Transfection ofHeLa-cells withpEGFP plasmid by impedance power-assisted electroporation. Biotechnol Bioeng 2005; 92:267-76. [PMID: 16161165 DOI: 10.1002/bit.20426] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Bioimpedance spectrometry was applied to study cell viability and pEGFP plasmid-transfection efficiency in electroporation (EP) of 20,000 HeLa cells with 0.3 microg DNA in 90 microl low conductivity 0.32 M sucrose medium of pH 7.5. Monopolar rectangular pulses, of field strength 75 V/mm, and pulse length 0.1 ms were applied in 1-16 repetitions with a 10-sec pause interval between pulses. Surviving cells were stained by crystal violet and counted using a confocal microscope. Transfected cells were fixed with 10% formaldehyde and counted as green spots in a fluorescence microscope. In the present investigation we used the method of bioimpedance spectrometry to analyze the effect of EP on survival and transfection ratio of cells in suspension. DC and low-frequency AC currents preferably pass through the medium due to the high impedance of the cell membrane. At frequencies above 10 kHz the impedance of the cell membrane starts to decrease and the impedance value of the cell suspension approach a lower limit value Rinfinity at infinite frequency. Recording of electrical impedance spectra of cells in culture was performed over a frequency range of 10 Hz to 125 kHz, allowing separation of the contribution from extracellular space and that of the cell membranes. A parallel resistance capacitance model of the cell suspension was used to evaluate the response of applying EP pulses. The values of the collective membrane resistance RM decay exponentially (r2=0.995) with the number of applied pulses. The ratio of the extrapolated value of the intact membrane resistance before pulsing, RM,0, and the value RM,N after each pulse makes an index of the effect of electroporation on the cells. The ratio RM,N/RM,0 as well as the relative change of the dissipation factor, tandelta, on the "Loss Change Index" (LCI) fits well a dose-response model (r2=0.98) with the number of applied pulses. The changes in the model parameters membrane resistance DeltaRM=[1-RM,N/RM,o] and loss factor [1-tandelta0/tandeltaN] correlate well with the transfection ratio and fraction of dead cells. Those parameters were used for power-assisted electroporation in monitoring, controlling, and optimizing the EP procedure.
Collapse
Affiliation(s)
- Jacob Glahder
- The Protein Laboratory, Panum Institute, University of Copenhagen, DK-2200 Copenhagen, Denmark
| | | | | | | |
Collapse
|
13
|
Abstract
The year 2004 represents a milestone for the biosensor research community: in this year, over 1000 articles were published describing experiments performed using commercially available systems. The 1038 papers we found represent an approximately 10% increase over the past year and demonstrate that the implementation of biosensors continues to expand at a healthy pace. We evaluated the data presented in each paper and compiled a 'top 10' list. These 10 articles, which we recommend every biosensor user reads, describe well-performed kinetic, equilibrium and qualitative/screening studies, provide comparisons between binding parameters obtained from different biosensor users, as well as from biosensor- and solution-based interaction analyses, and summarize the cutting-edge applications of the technology. We also re-iterate some of the experimental pitfalls that lead to sub-optimal data and over-interpreted results. We are hopeful that the biosensor community, by applying the hints we outline, will obtain data on a par with that presented in the 10 spotlighted articles. This will ensure that the scientific community at large can be confident in the data we report from optical biosensors.
Collapse
Affiliation(s)
- Rebecca L Rich
- Center for Biomolecular Interaction Analysis, University of Utah, Salt Lake City, UT 84132, USA
| | | |
Collapse
|
14
|
Leabu M, Uniyal S, Xie J, Xu YQ, Vladau C, Morris VL, Chan BMC. Integrin ?2?1 modulates EGF stimulation of Rho GTPase-dependent morphological changes in adherent human rhabdomyosarcoma RD cells. J Cell Physiol 2004; 202:754-66. [PMID: 15481063 DOI: 10.1002/jcp.20163] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
The ability of cells to undergo shape changes is essential for diverse cellular functions including cell growth, differentiation, and movement. The present study examines how an integration of the function of alpha2beta1 integrin with that of the receptor for epidermal growth factor (EGFR) modulates EGF-stimulated morphological changes in human rhabdomyosarcoma RD transfectant cells. Upon EGF stimulation, RD transfectant cells that lacked alpha2beta1 integrin expression (RDpF) underwent contraction; in contrast, expression of alpha2beta1 on RD cells (RDX2C2) resulted in transient cell spreading. Integrin alpha2 cytoplasmic domain played a critical role in the observed alpha2beta1-mediated conversion from a cell rounding to a cell spreading phenotype. Thus, the expression of an alpha2 cytoplasmic domain deletion variant (X2C0) or a chimeric alpha2beta1 containing the cytoplasmic domain of alpha4 (X2C4) or alpha5 (X2C5), instead of alpha2, failed to mediate spreading upon EGF stimulation. Using dominant negative (DN) mutants of RhoGTPases, results revealed that RhoA activation was required for both EGF-stimulated responses of cell rounding and spreading, Cdc42 functioned in the re-spreading of cells after undergoing EGF-stimulated contraction, and Rac1 was required in alpha2beta1-mediated RD cell spreading. Therefore, alpha2beta1 integrin function can switch the Rho GTPase-dependent cell shape changes in RD cells from an EGF-stimulated cell contraction to a spreading morphology. Together, results show that integrin alpha2 cytoplasmic domain plays an indispensable role in the ability of integrin alpha2beta1 to modulate EGF stimulation of Rho-GTPase-dependent morphological changes in RD cells.
Collapse
Affiliation(s)
- M Leabu
- Department of Cellular and Molecular Medicine, Carol Davila University of Medicine and Pharmacy, Bucharest, Romania
| | | | | | | | | | | | | |
Collapse
|