1
|
A comparative study on selectivity and sensitivity of new chromium and copper electrodes. Sci Rep 2022; 12:13400. [PMID: 35927324 PMCID: PMC9352785 DOI: 10.1038/s41598-022-17662-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Accepted: 07/28/2022] [Indexed: 11/29/2022] Open
Abstract
4-Methylcoumarin-7-yloxy-N-phenyl acetamide and 4-methylcoumarin-7-yloxy-N-4-nitrophenyl acetamide were synthesized and used as new ionophores in the carbon paste matrix to produce two novel potentiometric modified electrodes. The selectivity of the electrode changed from copper (II) to chromium (III) with the addition of a nitro group to the phenyl ring of the ionophore. The ionophores’ tendency to ions was confirmed by UV–visible spectrophotometry. Both electrodes were modified by multi-walled carbon nanotubes (MWCNTs) as an excellent modifier of carbon paste electrode (CPE). The best sensor response in the case of copper (II) selective CPE was obtained by 5% ionophore, 65% graphite powder, 5% MWCNT, and 25% paraffin oil. In addition, in the case of chromium (III) selective CPE, these conditions are 20% ionophore, 50% graphite powder, 5% MWCNT, and 25% paraffin oil. The copper (II) selective CPE showed a Nernstian slope of 32.15 mV/decade within the concentration range of 1.0 × 10–10–1.0 × 10–1 mol L−1, while chromium (III) selective CPE showed a Nernstian slope of 19.28 mV/decade over the concentration range of 1.0 × 10–10–7.0 × 10–3 mol L−1. The electrodes have short response time of less than 5 s and were used successfully to determine copper (II) in wastewater and to speciation of chromium (III) and chromium (VI).
Collapse
|
2
|
Brainina K, Stozhko N, Bukharinova M, Vikulova E. Nanomaterials: Electrochemical Properties and Application in Sensors. PHYSICAL SCIENCES REVIEWS 2018. [DOI: 10.1515/psr-2018-8050] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Abstract
The unique properties of nanoparticles make them an extremely valuable modifying material, being used in electrochemical sensors. The features of nanoparticles affect the kinetics and thermodynamics of electrode processes of both nanoparticles and redox reactions occurring on their surface. The paper describes theoretical background and experimental studies of these processes. During the transition from macro- to micro- and nanostructures, the analytical characteristics of sensors modify. These features of metal nanoparticles are related to their size and energy effects, which affects the analytical characteristics of developed sensors. Modification of the macroelectrode with nanoparticles and other nanomaterials reduces the detection limit and improves the degree of sensitivity and selectivity of measurements. The use of nanoparticles as transducers, catalytic constituents, parts of electrochemical sensors for antioxidant detection, adsorbents, analyte transporters, and labels in electrochemical immunosensors and signal-generating elements is described.
Collapse
|
3
|
Mashhadizadeh MH, Ramezani S, Rofouei MK. Development of a novel MWCNTs–triazene-modified carbon paste electrode for potentiometric assessment of Hg(II) in the aquatic environments. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2015; 47:273-80. [DOI: 10.1016/j.msec.2014.11.011] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2013] [Revised: 10/11/2014] [Accepted: 11/06/2014] [Indexed: 11/16/2022]
|
4
|
Afkhami A, Shirzadmehr A, Madrakian T, Bagheri H. New nano-composite potentiometric sensor composed of graphene nanosheets/thionine/molecular wire for nanomolar detection of silver ion in various real samples. Talanta 2015; 131:548-55. [DOI: 10.1016/j.talanta.2014.08.004] [Citation(s) in RCA: 69] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2014] [Revised: 07/20/2014] [Accepted: 08/02/2014] [Indexed: 10/24/2022]
|
5
|
A novel morphine electrochemical biosensor based on intercalative and electrostatic interaction of morphine with double strand DNA immobilized onto a modified Au electrode. Talanta 2015; 131:460-6. [DOI: 10.1016/j.talanta.2014.08.009] [Citation(s) in RCA: 48] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2014] [Revised: 08/03/2014] [Accepted: 08/04/2014] [Indexed: 11/17/2022]
|
6
|
Mashhadizadeh MH, Rasouli F. Design of a New Carbon Paste Electrode Modified with TiO2Nanoparticles to Use in an Electrochemical Study of Codeine and Simultaneous Determination of Codeine and Acetaminophen in Human Plasma Serum Samples. ELECTROANAL 2014. [DOI: 10.1002/elan.201400141] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
7
|
Jasmin JP, Cannizzo C, Dumas E, Chaussé A. Fabrication and characterization of all-covalent nanocomposite functionalized screen-printed voltammetric sensors. Electrochim Acta 2014. [DOI: 10.1016/j.electacta.2014.04.069] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
8
|
Fabrication of an effective electrochemical platform based on graphene and AuNPs for high sensitive detection of trace Cu2+. Electrochim Acta 2014. [DOI: 10.1016/j.electacta.2014.03.114] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
9
|
Çiftçi H, Tamer U, Metin AÜ, Alver E, Kizir N. Electrochemical copper (II) sensor based on chitosan covered gold nanoparticles. J APPL ELECTROCHEM 2014. [DOI: 10.1007/s10800-014-0676-0] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
10
|
Noyhouzer T, Valdinger I, Mandler D. Enhanced Potentiometry by Metallic Nanoparticles. Anal Chem 2013; 85:8347-53. [DOI: 10.1021/ac401744w] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- T. Noyhouzer
- Institute of Chemistry, The Hebrew University of Jerusalem, Jerusalem 91904, Israel
| | - I. Valdinger
- Institute of Chemistry, The Hebrew University of Jerusalem, Jerusalem 91904, Israel
| | - D. Mandler
- Institute of Chemistry, The Hebrew University of Jerusalem, Jerusalem 91904, Israel
| |
Collapse
|
11
|
|
12
|
Guo Z, Wei Y, Yang R, Liu JH, Huang XJ. Hydroxylation/carbonylation carbonaceous microspheres: A route without the need for an external functionalization to a “hunter” of lead(II) for electrochemical detection. Electrochim Acta 2013. [DOI: 10.1016/j.electacta.2012.08.106] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
13
|
Mashhadizadeh MH, Afshar E. Electrochemical investigation of clozapine at TiO2 nanoparticles modified carbon paste electrode and simultaneous adsorptive voltammetric determination of two antipsychotic drugs. Electrochim Acta 2013. [DOI: 10.1016/j.electacta.2012.09.004] [Citation(s) in RCA: 59] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
14
|
Mashhadizadeh MH, Afshar E. Electrochemical Studies and Selective Detection of Thioridazine Using a Carbon Paste Electrode Modified with ZnS Nanoparticles and Simultaneous Determination of Thioridazine and Olanzapine. ELECTROANAL 2012. [DOI: 10.1002/elan.201200422] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
15
|
Yang C, Chai Y, Yuan R, Xu W, Zhang T, Jia F. Conjugates of graphene oxide covalently linked ligands and gold nanoparticles to construct silver ion graphene paste electrode. Talanta 2012; 97:406-13. [DOI: 10.1016/j.talanta.2012.04.053] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2012] [Accepted: 04/27/2012] [Indexed: 11/17/2022]
|
16
|
Wei Y, Yang R, Yu XY, Wang L, Liu JH, Huang XJ. Stripping voltammetry study of ultra-trace toxic metal ions on highly selectively adsorptive porous magnesium oxide nanoflowers. Analyst 2012; 137:2183-91. [PMID: 22421740 DOI: 10.1039/c2an15939b] [Citation(s) in RCA: 64] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
We have demonstrated highly selective and sensitive detection of Pb(II) and Cd(II) using a highly selective adsorptive porous magnesium oxide (MgO) nanoflowers. The MgO nanoflower-modified glassy carbon electrode was electrochemically characterized using cyclic voltammetry; and the anodic stripping voltammetric performance of bound Pb(II) and Cd(II) was evaluated using square wave anodic stripping voltammetry (SWASV) analysis. The MgO nanoflower-modified electrode exhibited excellent sensing performance toward Pb(II) and Cd(II) that was never observed previously at bismuth (Bi)-based electrodes. Simultaneous additions of Pb(II) and Cd(II) were investigated in the linear range from 3.3 to 22 nM for Pb(II) and 40 to 140 nM for Cd(II), and detection limits of 2.1 pM and 81 pM were obtained, respectively. Some foreign ions, such as Cu(II), Zn(II) and Cr(III) do not interfere with the detection of Pb(II) and Cd(II). To the best of our knowledge, this is the first example of a highly adsorptive metal oxide with hierarchical micro/nanostructure that allows the detection of both Pb(II) and Cd(II) ions.
Collapse
Affiliation(s)
- Yan Wei
- Department of Chemistry, Wannan Medical College, Wuhu 241002, PR China
| | | | | | | | | | | |
Collapse
|
17
|
References. Anal Chem 2012. [DOI: 10.1201/b11478-14] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
18
|
Mashhadizadeh MH, Yousefi T, Nozad Golikand A. A nickel hexacyanoferrate and poly(1-naphthol) hybrid film modified electrode used in the selective electroanalysis of dopamine. Electrochim Acta 2012. [DOI: 10.1016/j.electacta.2011.10.070] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
|
19
|
Mashhadizadeh MH, Khani H, Shockravi A, Sadeghpour M. Determination of ultratrace levels of lead (II) in water samples using a modified carbon paste electrode based on a new podand. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2011. [DOI: 10.1016/j.msec.2011.07.021] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
20
|
Solid-contact Cu(II) ion-selective electrode based on 1,2-di-(o-salicylaldiminophenylthio)ethane. J Solid State Electrochem 2011. [DOI: 10.1007/s10008-011-1528-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
21
|
Oztekin Y, Ramanaviciene A, Ramanavicius A. Electrochemical Determination of Cu(II) Ions by 4-Formylphenylboronic Acid Modified Gold Electrode. ELECTROANAL 2011. [DOI: 10.1002/elan.201100121] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
22
|
Mashhadizadeh MH, Talemi RP. Used gold nano-particles as an on/off switch for response of a potentiometric sensor to Al(III) or Cu(II) metal ions. Anal Chim Acta 2011; 692:109-15. [DOI: 10.1016/j.aca.2011.02.028] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2010] [Revised: 02/07/2011] [Accepted: 02/12/2011] [Indexed: 10/18/2022]
|
23
|
Khani H, Rofouei MK, Arab P, Gupta VK, Vafaei Z. Multi-walled carbon nanotubes-ionic liquid-carbon paste electrode as a super selectivity sensor: application to potentiometric monitoring of mercury ion(II). JOURNAL OF HAZARDOUS MATERIALS 2010; 183:402-9. [PMID: 20692088 DOI: 10.1016/j.jhazmat.2010.07.039] [Citation(s) in RCA: 414] [Impact Index Per Article: 29.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2010] [Revised: 06/28/2010] [Accepted: 07/09/2010] [Indexed: 05/10/2023]
Abstract
In this article a super selectivity potentiometric methodology, using an ion-selective electrode, for determination of mercury ion(II) in aqueous solution was investigated. For modification of the electrode a room temperature ionic liquid, 1-n-butyl-3-methylimidazolium tetrafluoroborate (BMIM·BF(4)), was applied as a super conductive binder, and Multi-walled carbon nanotubes (MWCNTs) was used in the composition of the carbon paste to improve conductivity and transduction of chemical signal to electrical signal. Moreover, incorporation of 1-(2-ethoxyphenyl)-3-(3-nitrophenyl)triazene (ENTZ) as an ionophore to this composition caused to significantly enhanced selectivity toward Hg(II) ions over a wide concentration range of 1.0×10(-4) to 5.0×10(-9) M with a lower detection limit of 2.5×10(-9) M (0.5 ppb) and a Nernstian slope of 29.3±(0.2) mV decade(-1) of Hg(II) activity. The electrode has a short response time (∼5s) and can be used for at least 55 days without any considerable divergence in potentials, and the working pH range was 2.0-4.3. Finally, the proposed electrode was successfully used as an indicator for potentiometric determination of Hg(II) in dental amalgam and water samples.
Collapse
Affiliation(s)
- Hadi Khani
- Faculty of Chemistry, Tarbiat Moallem University, Mofateh, Tehran, Iran.
| | | | | | | | | |
Collapse
|