1
|
Utility of Atmospheric-Pressure Chemical Ionization and Photoionization Mass Spectrometry in Bottom-Up Proteomics. SEPARATIONS 2022. [DOI: 10.3390/separations9020042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
In a typical bottom-up proteomics workflow, proteins are enzymatically cleaved, and the resulting peptides are analyzed by HPLC with electrospray ionization (ESI) tandem mass spectrometry. This approach is practical and widely applied. It has, however, limitations mostly related to less efficient or even inefficient ionization of some peptides in ESI sources. Gas-phase ionization methods like atmospheric-pressure chemical ionization (APCI) or atmospheric-pressure photoionization (APPI) offer alternative ways of detecting various analytes. This work is a systematic study of the ionization efficiencies of peptides in ESI, APCI, and APPI and the applicability of the mentioned ionizations in proteomics. A set of peptide standards and bovine serum albumin digests were examined using a high-resolution mass spectrometer coupled to an ultra HPLC system. Since the ionization efficiency in APCI and APPI depends strongly on experimental conditions, the ion source settings and mobile phase compositions were optimized for each ionization technique. As expected, tryptic peptides were best detected using ESI. The numbers of chymotrypsin peptides successfully detected by ESI, APPI, and APCI were comparable. In the case of Glu-C digest, APPI detected the highest number of peptides. The results suggest that gas-phase ionization techniques, particularly APPI, are an interesting alternative for detecting peptides and delivering complementary data in proteomics.
Collapse
|
2
|
Rapid quantitative determination of blood propofol concentration throughout perioperative period by negative photoionization ion mobility spectrometer with solvent-assisted neutral desorption. Anal Chim Acta 2020; 1142:118-126. [PMID: 33280689 DOI: 10.1016/j.aca.2020.10.043] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2020] [Revised: 10/19/2020] [Accepted: 10/21/2020] [Indexed: 12/15/2022]
Abstract
Rapid and quantitative determination of blood propofol concentration is important for anesthesiologists to accurately control intraoperative propofol dose, timely monitor physiological statuses of patients and greatly improve the safety of surgery. Herein, a dopant-assisted negative photoionization ion mobility spectrometer with the optimized ionization region structure and the three-way inlet design was developed, increasing the generation ratio of the reactant ions O2-, and improving the ionization efficiency of propofol molecules. Besides, the addition of methanol-anisole solution during injection promoted the neutral desorption of propofol in blood, further improving the detection sensitivity by an order of magnitude, eliminating any sample pretreatment and effectively reducing the single analysis time to less than 1 min compared to the previous article. The dual calibration quantitative method, i.e. the method of calibrating the O2- concentration and the sample concentration changes during the entire process of detecting propofol through the integral value of M·O2- and the maximum signal intensity of O2-, successfully achieved accurate quantification of blood propofol. And the linear calibration curve of propofol was obtained with the range of 0.1-15 ng μL-1 and with the limit of detection of 0.03 ng μL-1, which was fulfilled to conduct propofol determination throughout the perioperative period. Finally, this method was applied to clinically measure the blood propofol concentration in patients newly regained consciousness with concentrations ranging from 0.2 ng μL-1 to 3 ng μL-1, and it turned out that the older patient had the lower propofol concentration in blood.
Collapse
|
3
|
Determination of Methomyl Residue in Tobacco Samples by Heart-Cutting Two-Dimensional Liquid Chromatography with Tandem Mass Spectrometry. Int J Anal Chem 2020; 2020:8813142. [PMID: 33110427 PMCID: PMC7578710 DOI: 10.1155/2020/8813142] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2020] [Revised: 09/04/2020] [Accepted: 09/18/2020] [Indexed: 11/17/2022] Open
Abstract
A novel heart-cutting two-dimensional liquid chromatography coupled with tandem mass spectrometry (2D-LC-MS/MS) was developed for the qualitative and quantitative analysis of methomyl residue in tobacco. Compared to traditional methodologies, fairly high sensitivity and stability were achieved, and the sample procedure was simplified in the two-dimensional liquid chromatography (2D-LC) method. Although methomyl had poor retention performance in most of the reversed-phase liquid chromatography (RPLC) columns, an effective RP/RP strategy was successfully facilitated. An XB-Phenyl column was employed in the first dimension to effectively remove thousands of interference compounds in the matrix. In the second dimension, an ADME column was applied for further separation. After optimization of the separation conditions, a six-way valve was utilized for direct transformation of the target fraction from the 1st column to the 2nd column. A dynamic range of 2.5 ng/mL to 500 ng/mL was achieved with correlation coefficient (r 2) greater than 0.9995. The limit of detection and limit of quantification were determined to be 0.69 and 2.30 ng/mL, respectively. The 2D-LC method shows high sensitivity, good reproducibility, and recovery for methomyl in tobacco samples. Therefore, the new method was quite suitable for routine analysis.
Collapse
|
4
|
Vargas Medina DA, Maciel EVS, de Toffoli AL, Lanças FM. Miniaturization of liquid chromatography coupled to mass spectrometry. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.115910] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
5
|
Mejía-Carmona K, Maciel EVS, Lanças FM. Miniaturized liquid chromatography applied to the analysis of residues and contaminants in food: A review. Electrophoresis 2020; 41:1680-1693. [PMID: 32359175 DOI: 10.1002/elps.202000019] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2020] [Revised: 04/15/2020] [Accepted: 04/17/2020] [Indexed: 12/21/2022]
Abstract
The humankind is pretty dependent on food to control several biological processes into the organism. As the world population increases, the demand for foodstuffs follows the same trend claiming for a high food production situation. For this reason, a substantial amount of chemicals is used in agriculture and livestock husbandries every year, enhancing the likelihood of contaminated foodstuffs being commercialized. This outlook becomes a public health concern; thus, the governmental regulatory agencies impose laws to control the residues and contaminants in food matrices. Currently, one of the most important analytical techniques to perform it is LC. Despite its already recognized effectiveness, it is often time consuming and requires significant volumes of reagents, which are transformed into toxic waste. In this context, miniaturized LC modes emerge as a greener and more effective analytical technique. They have remarkable advantages, including higher sensitivity, lower sample amount, solvent and stationary phase requirements, and more natural coupling to MS. In this review, most of the critical characteristics of them are discussed, focusing on the benchtop instruments and their related analytical columns. Additionally, a discussion regarding the last 10 years of publications reporting miniaturized LC application for the analysis of natural and industrial food samples is categorized. The main chemical classes as applied in the crops are highlighted, including pesticides, veterinary drugs, and mycotoxins.
Collapse
Affiliation(s)
- Karen Mejía-Carmona
- São Carlos Institute of Chemistry, University of São Paulo, São Paulo, Brazil
| | | | | |
Collapse
|
6
|
Vrkoslav V, Rumlová B, Strmeň T, Cvačka J. Temperature-programmed capillary high-performance liquid chromatography with atmospheric pressure chemical ionization mass spectrometry for analysis of fatty acid methyl esters. J Sep Sci 2020; 43:2579-2588. [PMID: 32277790 DOI: 10.1002/jssc.201901235] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2019] [Revised: 04/07/2020] [Accepted: 04/07/2020] [Indexed: 11/10/2022]
Abstract
A new capillary high-performance liquid chromatography method with atmospheric pressure chemical ionization mass spectrometry was developed for the analysis of fatty acid methyl esters and long-chain alcohols. The chromatographic separation was achieved using a Zorbax SB-C18 HPLC column (0.3 × 150 mm, 3.5 μm) with a mobile phase composed of acetonitrile and formic acid and delivered isocratically at a flow rate of 10 μL/min. The column temperature was programmed simply, using a common column oven. Good reproducibility of the temperature profile and retention times were achieved. The temperature programming during the isocratic high-performance liquid chromatography run had a similar effect as a solvent gradient; it reduced retention times of later eluting analytes and improved their detection limits. Two atmospheric pressure chemical ionization sources of the mass spectrometry detector were compared: an enclosed conventional ion source and an in-house made ion source with a glass microchip nebulizer. The enclosed source provided better detectability of saturated fatty acid methyl esters and made it possible to determine the double bond positions using acetonitrile-related adducts, while the open chip-based source provided better analytical figures of merit for unsaturated fatty acid methyl esters. Temperature-programmed capillary high-performance liquid chromatography is a promising method for analyzing neutral lipids in lipidomics and other applications.
Collapse
Affiliation(s)
- Vladimír Vrkoslav
- Institute of Organic Chemistry and Biochemistry, Czech Academy of Sciences, Prague 6, Czech Republic
| | - Barbora Rumlová
- Institute of Organic Chemistry and Biochemistry, Czech Academy of Sciences, Prague 6, Czech Republic.,Department of Analytical Chemistry, Faculty of Science, Charles University in Prague, Prague 2, Czech Republic
| | - Timotej Strmeň
- Institute of Organic Chemistry and Biochemistry, Czech Academy of Sciences, Prague 6, Czech Republic.,Department of Analytical Chemistry, Faculty of Science, Charles University in Prague, Prague 2, Czech Republic
| | - Josef Cvačka
- Institute of Organic Chemistry and Biochemistry, Czech Academy of Sciences, Prague 6, Czech Republic.,Department of Analytical Chemistry, Faculty of Science, Charles University in Prague, Prague 2, Czech Republic
| |
Collapse
|
7
|
Miniaturized liquid chromatography focusing on analytical columns and mass spectrometry: A review. Anal Chim Acta 2020; 1103:11-31. [DOI: 10.1016/j.aca.2019.12.064] [Citation(s) in RCA: 47] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2019] [Revised: 12/19/2019] [Accepted: 12/20/2019] [Indexed: 12/17/2022]
|
8
|
Pöhö P, Vaikkinen A, Haapala M, Kylli P, Kostiainen R. Capillary photoionization: interface for low flow rate liquid chromatography-mass spectrometry. Analyst 2019; 144:2867-2871. [DOI: 10.1039/c9an00258h] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
The first report on capillary photoionization interfacing a liquid chromatograph and mass spectrometer.
Collapse
Affiliation(s)
- Päivi Pöhö
- Drug Research Program
- Division of Pharmaceutical Chemistry and Technology
- Faculty of Pharmacy
- University of Helsinki
- 00014 Finland
| | - Anu Vaikkinen
- Drug Research Program
- Division of Pharmaceutical Chemistry and Technology
- Faculty of Pharmacy
- University of Helsinki
- 00014 Finland
| | - Markus Haapala
- Drug Research Program
- Division of Pharmaceutical Chemistry and Technology
- Faculty of Pharmacy
- University of Helsinki
- 00014 Finland
| | - Petri Kylli
- Drug Research Program
- Division of Pharmaceutical Chemistry and Technology
- Faculty of Pharmacy
- University of Helsinki
- 00014 Finland
| | - Risto Kostiainen
- Drug Research Program
- Division of Pharmaceutical Chemistry and Technology
- Faculty of Pharmacy
- University of Helsinki
- 00014 Finland
| |
Collapse
|
9
|
Vrkoslav V, Rumlová B, Strmeň T, Nekvasilová P, Šulc M, Cvačka J. Applicability of low-flow atmospheric pressure chemical ionization and photoionization mass spectrometry with a microfabricated nebulizer for neutral lipids. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2018; 32:639-648. [PMID: 29457286 DOI: 10.1002/rcm.8086] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2017] [Revised: 02/05/2018] [Accepted: 02/06/2018] [Indexed: 06/08/2023]
Abstract
RATIONALE Mass spectrometry with atmospheric pressure chemical ionization (APCI) or photoionization (APPI) is widely used for neutral lipids involved in many fundamental processes in living organisms. Commercial APCI and APPI sources operate at high flow rates compatible with conventional high-performance liquid chromatography (HPLC). However, lipid analysis is often limited by a small amount of sample, which requires low flow rate separations like capillary or micro-HPLC. Therefore, APCI and APPI suitable for microliter-per-minute flow rates need to be developed and applied for neutral lipids. METHODS A micro-APCI/APPI source with a heated chip nebulizer was assembled and mounted on a Thermo ion trap instrument. The ion source operated in APCI, APPI or dual mode was optimized for low microliter-per-minute sample flow rates. The source performance was investigated for squalene, wax esters, fatty acid methyl esters, triacylglycerols, and cholesterol. RESULTS The ion source behaved as a mass-flow-sensitive detector. Direct infusion of methyl oleate showed superior analytical figures of merit when compared with high-flow ion sources. A detection limit of 200 pmol/mL and a linear dynamic range spanning three orders of magnitude were measured for micro-APCI. The mass spectra of most lipids differed from high flow rate spectra. Unlike micro-APCI, micro-APPI spectra were complicated by odd-electron species. Dual APCI/APPI mode did not show any benefits for neutral lipids. Applications for lipid samples were demonstrated. CONCLUSIONS Micro-APCI-MS is a useful detection technique for neutral lipids at microliter-per-minute flow rates. It offers high sensitivity and high quality of spectra in direct infusion mode and promises successful utilization in capillary and micro-HPLC applications.
Collapse
Affiliation(s)
- Vladimír Vrkoslav
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo nám. 2, CZ-166 10, Prague 6, Czech Republic
| | - Barbora Rumlová
- Department of Analytical Chemistry, Faculty of Science, Charles University in Prague, Hlavova 2030/8, CZ-128 43, Prague 2, Czech Republic
| | - Timotej Strmeň
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo nám. 2, CZ-166 10, Prague 6, Czech Republic
- Department of Analytical Chemistry, Faculty of Science, Charles University in Prague, Hlavova 2030/8, CZ-128 43, Prague 2, Czech Republic
| | - Pavlína Nekvasilová
- Department of Analytical Chemistry, Faculty of Science, Charles University in Prague, Hlavova 2030/8, CZ-128 43, Prague 2, Czech Republic
| | - Miloslav Šulc
- Czech University of Life Sciences, Faculty of Agrobiology Natural and Food Resources, Department of Chemistry, Kamýcká 129, CZ-165 00, Prague 6, Czech Republic
| | - Josef Cvačka
- Institute of Organic Chemistry and Biochemistry of the Czech Academy of Sciences, Flemingovo nám. 2, CZ-166 10, Prague 6, Czech Republic
- Department of Analytical Chemistry, Faculty of Science, Charles University in Prague, Hlavova 2030/8, CZ-128 43, Prague 2, Czech Republic
| |
Collapse
|
10
|
Kauppila TJ, Syage JA, Benter T. Recent developments in atmospheric pressure photoionization-mass spectrometry. MASS SPECTROMETRY REVIEWS 2017; 36:423-449. [PMID: 25988849 DOI: 10.1002/mas.21477] [Citation(s) in RCA: 69] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/12/2015] [Accepted: 04/29/2015] [Indexed: 05/28/2023]
Abstract
Recent developments in atmospheric pressure photoionization (APPI), which is one of the three most important ionization techniques in liquid chromatography-mass spectrometry, are reviewed. The emphasis is on the practical aspects of APPI analysis, its combination with different separation techniques, novel instrumental developments - especially in gas chromatography and ambient mass spectrometry - and the applications that have appeared in 2009-2014. © 2015 Wiley Periodicals, Inc. Mass Spec Rev 36:423-449, 2017.
Collapse
Affiliation(s)
- Tiina J Kauppila
- Faculty of Pharmacy, University of Helsinki, P.O. Box 56, 00014, Finland
| | - Jack A Syage
- Morpho Detection, 1251 E. Dyer Rd., Santa Ana, CA 92705, USA
| | - Thorsten Benter
- Department of Physical and Theoretical Chemistry, University of Wuppertal, Gaußstr. 20, 42119 Wuppertal, Germany
| |
Collapse
|
11
|
Fanali C, Dugo L, Dugo P, Mondello L. Capillary-liquid chromatography (CLC) and nano-LC in food analysis. Trends Analyt Chem 2013. [DOI: 10.1016/j.trac.2013.05.021] [Citation(s) in RCA: 64] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
12
|
Andreu V, Picó Y. Determination of currently used pesticides in biota. Anal Bioanal Chem 2012; 404:2659-81. [PMID: 22918537 DOI: 10.1007/s00216-012-6331-x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2012] [Revised: 07/16/2012] [Accepted: 08/03/2012] [Indexed: 01/06/2023]
Abstract
Although pesticides enable control of the quantity and quality of farm products and food, and help to limit diseases in humans transmitted by insects and rodents, they are regarded as among the most dangerous environmental contaminants because of their tendency to bioaccumulate, and their mobility and long-term effects on living organisms. In the past decade, more analytical methods for accurate identification and quantitative determination of traces of pesticides in biota have been developed to improve our understanding of their risk to ecosystems and humans. Because sample preparation is often the rate-determining step in analysis of pesticides in biological samples, this review first discusses extraction and clean-up procedures, after a brief introduction to the classes, and the methods used in the analysis of pesticides in biota. The analytical methods, especially chromatographic techniques and immunoassay-based methods, are reviewed in detail, and their corresponding advantages, limitations, applications, and prospects are also discussed. This review mainly covers reports published since 2008 on methods for analysis of currently used pesticides in biota.
Collapse
Affiliation(s)
- Vicente Andreu
- Centro de Investigaciones sobre Desertificación -CIDE, Moncada, Valencia, Spain
| | | |
Collapse
|