1
|
Darestani-Farahani M, Mendoza Montealegre I, Tavakkoli Gilavan M, Kirby T, Selvaganapathy PR, Kruse P. A highly sensitive ion-selective chemiresistive sensor for online monitoring of lead ions in water. Analyst 2024; 149:2915-2924. [PMID: 38578133 DOI: 10.1039/d4an00159a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/06/2024]
Abstract
Dissolved lead is a serious but common health hazard in drinking water, yet there is still no practical way to monitor its levels continuously in the distribution system or at the point of use. Here we propose using a lead-selective membrane on top of a chemiresistive device to continuously measure Pb2+ ion concentrations in real time. The detection limit was lowered by stabilizing the surface of the resistive film with sodium hydroxide and 15-crown-5 ether and optimizing the sensor geometry to maximize the effective surface area. The detection mechanism is based on the complexation of the Pb2+ ions by the lead ionophores within the membrane, thus modulating the interactions between the ionophores and the chemiresistive film. The limit of detection of the fabricated devices was reliably below 2 μg L-1, with concentrations up to 3 mg L-1 routinely quantifiable over several measurement cycles. The chemiresistive sensors can thus achieve lower detection limits than potentiometric devices while being more robust and simpler to fabricate by omitting the reference electrode. Ion-selective membrane-covered chemiresistors can therefore be deployed to continuously monitor drinking water sources and detect harmful levels of lead in real time.
Collapse
Affiliation(s)
- Maryam Darestani-Farahani
- Department of Chemistry and Chemical Biology, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4M1, Canada.
| | - Isabella Mendoza Montealegre
- Department of Chemistry and Chemical Biology, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4M1, Canada.
| | - Mehraneh Tavakkoli Gilavan
- School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L7, Canada
| | - Thomas Kirby
- Department of Chemistry and Chemical Biology, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4M1, Canada.
| | - Ponnambalam Ravi Selvaganapathy
- School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L7, Canada
- Department of Mechanical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L7, Canada
| | - Peter Kruse
- Department of Chemistry and Chemical Biology, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4M1, Canada.
| |
Collapse
|
2
|
Ultrathin ion-selective membranes for trace detection of lead, copper and silver ions. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2022.140870] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
3
|
Lisak G. Reliable environmental trace heavy metal analysis with potentiometric ion sensors - reality or a distant dream. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2021; 289:117882. [PMID: 34364114 DOI: 10.1016/j.envpol.2021.117882] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2021] [Revised: 07/13/2021] [Accepted: 07/29/2021] [Indexed: 06/13/2023]
Abstract
Over two decades have passed since polymeric membrane ion-selective electrodes were found to exhibit sufficiently lower detection limits. This in turn brought a great promise to measure trace level concentrations of heavy metals using potentiometric ion sensors at environmental conditions. Despite great efforts, trace analysis of heavy metals using ion-selective electrodes at environmental conditions is still not commercially available. This work will predominantly concentrate on summarizing and evaluating prospects of using potentiometric ion sensors in view of environmental determination of heavy metals in on-site and on-line analysis modes. Challenges associated with development of reliable potentiometric sensors to be operational in environmental conditions will be discussed and reasoning behind unsuccessful efforts to develop potentiometric on-site and on-line environmental ion sensors will be explored. In short, it is now clear that solely lowering the detection limit of the ion-selective electrodes does not guarantee development of successful sensors that would meet the requirement of environmental matrices over long term usage. More pressing challenges of the properties and the performance of the potentiometric sensors must be addressed first before considering extending their sensitivity to low analyte concentrations. These are, in order of importance, selectivity of the ion-selective membrane to main ion followed by the membrane resistance to parallel processes, such as water ingress to the ISM, light sensitivity, change in temperature, presence of gasses in solution and pH and finally resistance of the ion-selective membrane to fouling. In the future, targeted on-site and on-line environmental sensors should be developed, addressing specific environmental conditions. Thus, ion-selective electrodes should be developed with the intention to be suitable to the operational environmental conditions, rather than looking at universal sensor design validated in the idealized and simple sample matrices.
Collapse
Affiliation(s)
- Grzegorz Lisak
- School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore, 639798, Singapore; Residues and Resource Reclamation Centre, Nanyang Environment and Water Research Institute, Nanyang Technological University, 1 Cleantech Loop, Singapore, 637141, Singapore.
| |
Collapse
|
4
|
Improving the stability of Pb2+ ion-selective electrodes by using 3D polyaniline nanowire arrays as the inner solid-contact transducer. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2021.138414] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
5
|
Fan Y, Xu Z, Huang Y, Wang T, Zheng S, DePasquale A, Brüeckner C, Lei Y, Li B. Long-term continuous and real-time in situ monitoring of Pb(II) toxic contaminants in wastewater using solid-state ion selective membrane (S-ISM) Pb and pH auto-correction assembly. JOURNAL OF HAZARDOUS MATERIALS 2020; 400:123299. [PMID: 32947704 DOI: 10.1016/j.jhazmat.2020.123299] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2020] [Revised: 06/17/2020] [Accepted: 06/22/2020] [Indexed: 05/12/2023]
Abstract
Lead (Pb) contaminants in wastewater have inhibited microbial activities and thus exerted high energy consumption in wastewater treatment plants (WWTPs). Current Pb monitoring has been conducted ex situ and off line, unable to affect real-time proactive control and operation. This study targets the crucial challenge of better and faster Pb monitoring by developing novel mm-sized screen-printed solid-state ion-selective membrane (S-ISM) Pb sensors with low-cost, high accuracy and long-term durability and that enable real-time in situ monitoring of Pb(II) ion contamination down to low concentrations (15 ppb-960 ppb) in wastewater. An innovative pH auto-correction data-driven model was built to overcome the inextricable pH inferences on Pb(II) ISM sensors in wastewater. Electrochemical impedance spectroscopy (EIS) and cyclic voltammograms (CV) analysis showed (3,4-ethylenedioxythiophene, EDOT) deposited onto the mm-sized screen-printed carbon electrodes using electropolymerization effectively alleviated the interferences from dissolved oxygen and improved long-term stability in wastewater. Monte Carlo simulation of the nitrification process predicted that real-time, and high accurate in situ monitoring of Pb(II) in wastewater and swift feedback control could save ∼53 % of energy consumption by alleviating the errors from pH and DO impacts in WWTPs.
Collapse
Affiliation(s)
- Yingzheng Fan
- Department of Civil & Environmental Engineering, University of Connecticut, Storrs, CT 06269-3037, United States
| | - Zhiheng Xu
- Department of Civil & Environmental Engineering, University of Connecticut, Storrs, CT 06269-3037, United States
| | - Yuankai Huang
- Department of Civil & Environmental Engineering, University of Connecticut, Storrs, CT 06269-3037, United States
| | - Tianbao Wang
- Department of Civil & Environmental Engineering, University of Connecticut, Storrs, CT 06269-3037, United States
| | - Sikai Zheng
- Department of Civil & Environmental Engineering, University of Connecticut, Storrs, CT 06269-3037, United States
| | - Alex DePasquale
- Department of Civil & Environmental Engineering, University of Connecticut, Storrs, CT 06269-3037, United States
| | - Christian Brüeckner
- Department of Chemistry, University of Connecticut, Storrs, CT 06269-3060, United States
| | - Yu Lei
- Department of Chemical and Biomedical Engineering, University of Connecticut, Storrs, CT 06269-3222, United States
| | - Baikun Li
- Department of Civil & Environmental Engineering, University of Connecticut, Storrs, CT 06269-3037, United States.
| |
Collapse
|
6
|
Mahmoud AM, Saad MN, Elzanfaly ES, Amer SM, Essam HM. An electrochemical sensing platform to determine tetrahydrozoline HCl in pure form, pharmaceutical formulation, and rabbit aqueous humor. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2020; 12:2903-2913. [PMID: 32930213 DOI: 10.1039/d0ay00882f] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
In the pharmaceutical industry, finding cost-effective and real-time analyzers that provide valid data is a good aim. The purpose of this work was to propose a link between the pharmaceutical industry and the recent innovations in solid-contact ion-selective electrodes (SC-ISEs) for the utilization of these electrodes as real-time analyzers to evaluate the concentration of tetrahydrozoline HCl in different matrices. The backbone of these new potentiometric sensors is the conjunction of calix[6]arene and (2-hydroxypropyl)-β-cyclodextrin as molecular recognition elements and a network of multi-walled carbon nanotubes as a solid transducer material between an ionophore-doped PVC membrane and microfabricated Cu electrodes. The proposed sensors were optimized to determine tetrahydrozoline, and their performances were assessed according to the IUPAC recommendations. The proposed solid-contact sensors were compared with liquid contact sensors, and the former sensors were found to be better than the latter sensors in terms of durability, handling, and easier adaptation to industry with comparable sensitivity. The measurements were implemented using phosphate buffer (pH: 6). The best obtained linearity range was 1 × 10-2 to 1 × 10-7 M, and the best LOD was 1 × 10-8 M. The sensors with the best performance were successfully applied to determine tetrahydrozoline in a pharmaceutical eye preparation and rabbit tears. The obtained results were statistically compared to those obtained by the official method of analysis, and no significant difference was obtained. The eco-score of the method was assessed using the eco-scale tool and also compared with that of the official method. The proposed approach was validated according to the International Council for Harmonisation (ICH) guidelines.
Collapse
Affiliation(s)
- Amr M Mahmoud
- Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, El-Kasr El-Aini Street, 11562 Cairo, Egypt.
| | - Martin N Saad
- Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, El-Kasr El-Aini Street, 11562 Cairo, Egypt.
| | - Eman S Elzanfaly
- Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, El-Kasr El-Aini Street, 11562 Cairo, Egypt.
| | - Sawsan M Amer
- Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, El-Kasr El-Aini Street, 11562 Cairo, Egypt.
| | - Hebatallah M Essam
- Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, El-Kasr El-Aini Street, 11562 Cairo, Egypt.
| |
Collapse
|
7
|
Stable Pb2+ ion-selective electrodes based on polyaniline-TiO2 solid contacts. Anal Chim Acta 2020; 1094:26-33. [DOI: 10.1016/j.aca.2019.10.008] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2019] [Revised: 09/14/2019] [Accepted: 10/06/2019] [Indexed: 12/20/2022]
|
8
|
Disposable Multi-Walled Carbon Nanotubes-Based Plasticizer-Free Solid-Contact Pb 2+-Selective Electrodes with a Sub-PPB Detection Limit †. SENSORS 2019; 19:s19112550. [PMID: 31167473 PMCID: PMC6603586 DOI: 10.3390/s19112550] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/13/2019] [Revised: 05/31/2019] [Accepted: 06/02/2019] [Indexed: 11/20/2022]
Abstract
Potentiometric plasticizer-free solid-contact Pb2+-selective electrodes based on copolymer methyl methacrylate-n-butyl acrylate (MMA-BA) as membrane matrix and multi-walled carbon nanotubes (MWCNTs) as intermediate ion-to-electron transducing layer have been developed. The disposable electrodes were prepared by drop-casting the copolymer membrane onto a layer of MWCNTs, which deposited on golden disk electrodes. The obtained electrodes exhibited a sub-ppb level detection limit of 10−10 mol·L−1. The proposed electrodes demonstrated a Nernstian slope of 29.1 ± 0.5 mV/decade in the linear range from 2.0 × 10−10 to 1.5 × 10−3 mol·L−1. No interference from gases (O2 and CO2) or water films was observed. The electrochemical impedance spectroscopy of the fabricated electrodes was compared to that of plasticizer-free Pb2+-selective electrodes without MWCNTs as intermediated layers. The plasticizer-free MWCNTs-based Pb2+-selective electrodes can provide a promising platform for Pb(II) detection in environmental and clinical application.
Collapse
|
9
|
|
10
|
A solid-contact Pb 2+ - selective electrode based on electrospun polyaniline microfibers film as ion-to-electron transducer. Electrochim Acta 2017. [DOI: 10.1016/j.electacta.2017.01.162] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
11
|
Yu K, He N, Kumar N, Wang N, Bobacka J, Ivaska A. Electrosynthesized polypyrrole/zeolite composites as solid contact in potassium ion-selective electrode. Electrochim Acta 2017. [DOI: 10.1016/j.electacta.2017.01.009] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
12
|
A novel all-solid-state ammonium electrode with polyaniline and copolymer of aniline/2,5-dimethoxyaniline as transducers. J Electroanal Chem (Lausanne) 2015. [DOI: 10.1016/j.jelechem.2014.12.041] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
13
|
Xu S, Yuan Q, Yu S, Wu X. Single-Piece Solid-Contact Pb2+-Selective Electrodes Based on Thiophene Oligomer. ELECTROANAL 2012. [DOI: 10.1002/elan.201200195] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
14
|
|
15
|
Lisak G, Bobacka J, Lewenstam A. Recovery of nanomolar detection limit of solid-contact lead (II)-selective electrodes by electrode conditioning. J Solid State Electrochem 2012. [DOI: 10.1007/s10008-012-1725-4] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
16
|
Ping J, Wang Y, Ying Y, Wu J. Application of Electrochemically Reduced Graphene Oxide on Screen-Printed Ion-Selective Electrode. Anal Chem 2012; 84:3473-9. [DOI: 10.1021/ac203480z] [Citation(s) in RCA: 135] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Affiliation(s)
- Jianfeng Ping
- College of Biosystems Engineering and Food
Science, Zhejiang University, Hangzhou
310058, PR China
| | - Yixian Wang
- College of Biosystems Engineering and Food
Science, Zhejiang University, Hangzhou
310058, PR China
| | - Yibin Ying
- College of Biosystems Engineering and Food
Science, Zhejiang University, Hangzhou
310058, PR China
| | - Jian Wu
- College of Biosystems Engineering and Food
Science, Zhejiang University, Hangzhou
310058, PR China
| |
Collapse
|