Alnaanah SA, Mendes SB. Investigating the influence of solvent type and pH on protein adsorption onto silica surface by evanescent-wave cavity ring-down spectroscopy.
ANAL SCI 2024;
40:1089-1099. [PMID:
38512454 DOI:
10.1007/s44211-024-00529-3]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Accepted: 01/31/2024] [Indexed: 03/23/2024]
Abstract
Several studies have explored the adsorption of various proteins onto solid-liquid interfaces, revealing the crucial role of buffer solutions in biological processes. However, a comprehensive evaluation of the buffer's influence on protein absorption onto fused silica is still lacking. This study employs evanescent-wave cavity ring-down spectroscopy (EW-CRDS) to assess the influence of buffer solutions and pH on the adsorption kinetics of three globular proteins: hemoglobin (Hb), myoglobin (Mb), and cytochrome c (Cyt-C) onto fused silica. The EW-CRDS tool, with a ring-down time of 1.4 μ s and a minimum detectable absorbance of 1 × 10 - 6 , enabled precise optical measurements at solid-liquid interfaces. The three heme proteins' adsorption behavior was investigated at pH 7 in three different solvents: deionized (DI) water, tris(hydroxymethyl)-aminomethane hydrochloride (Tris-HCl), and phosphate buffered saline (PBS). For each protein, the surface coverage, the adsorption and desorption constants, and the surface equilibrium constant were optically measured by our EW-CRDS tool. Depending on the nature of each solvent, the proteins showed a completely different adsorption trend on the silica surface. The adsorption of Mb on the silica surface was depressed in the presence of both Tris-HCl and PBS buffers compared with unbuffered (DI water) solutions. In contrast, Cyt-C adsorption appears to be relatively unaffected by the choice of buffer, as it involves strong electrostatic interactions with the surface. Notably, Hb exhibits an opposite trend, with enhanced protein adsorption in the presence of Tris-HCl and PBS buffer. The pH investigations demonstrated that the electrostatic interactions between the proteins and the surface had a major influence on protein adsorption on the silica surface, with adsorption being greatest when the pH values were around the protein's isoelectric point. This study demonstrated the ability of the highly sensitive EW-CRDS tool to study the adsorption events of the evanescent-field-confined protein species in real-time at low surface coverages with fast resolution, making it a valuable tool for studying biomolecule kinetics at solid-liquid interfaces.
Collapse