1
|
Gupta A, Rotake D, Darji A. Sensing lead ions in water: a comprehensive review on strategies and sensor materials. ANAL SCI 2024; 40:997-1021. [PMID: 38523231 DOI: 10.1007/s44211-024-00547-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Accepted: 02/25/2024] [Indexed: 03/26/2024]
Abstract
It is well-known fact that elevated lead ions (Pb2+), the third most toxic among heavy metal ions in aqueous systems, pose a threat to human health and aquatic ecosystems when they exceed permissible limits. Pb2+ is commonly found in industrial waste and fertilizers, contaminating water sources and subsequently entering the human body, causing various adverse health conditions. Unlike being expelled, Pb2+ accumulates within the body, posing potential health risks. The harmful impact of presence of Pb2+ in water have prompted researchers to diligently work toward maintaining water quality. Recognizing the importance of Pb2+, this review article makes a sincere and effective effort to address the issues associated with Pb2+. This overview article gives insights into various sensing approaches to detect Pb2+ in water using different sensing materials, including 2-dimensional materials, thiols, quantum dots, and polymers. Herein, different sensing approaches such as electrochemical, optical, field effect transistor-based, micro-electromechanical system-based, and chemi resistive are thoroughly explained. Field effect transistor-based and chemiresistive work on similar principles and are compared on the basis of their fabrication processes and sensing capabilities. In conclusion, future directions for chemiresistive sensors in Pb2+ detection are proposed, emphasizing their simplicity, portability, straightforward functionality, and ease of fabrication. Notably, it sheds light on various thiol and ligand compounds and coupling strategies utilized in Pb2+ detection. This comprehensive study is expected to benefit individuals engaged in Pb2+ detection.
Collapse
Affiliation(s)
- Anju Gupta
- Department of Electronics Engineering, Sardar Vallabhbhai National Institute of Technology, Ichchhanath, Surat, 395007, Gujarat, India
- Department of Biomedical Engineering, Shri Ramdeobaba College of Engineering and Management, Ramdeo Tekdi, Nagpur, 440013, Maharashtra, India
| | - Dinesh Rotake
- Department of Electrical Engineering, Indian Institute of Technology Hyderabad, Kandi, Sangareddy, Hyderabad, 502284, Telangana, India.
| | - Anand Darji
- Department of Electronics Engineering, Sardar Vallabhbhai National Institute of Technology, Ichchhanath, Surat, 395007, Gujarat, India
| |
Collapse
|
2
|
Fernández H, Zon MA, Maccio SA, Alaníz RD, Di Tocco A, Carrillo Palomino RA, Cabas Rodríguez JA, Granero AM, Arévalo FJ, Robledo SN, Pierini GD. Multivariate Optimization of Electrochemical Biosensors for the Determination of Compounds Related to Food Safety-A Review. BIOSENSORS 2023; 13:694. [PMID: 37504093 PMCID: PMC10377565 DOI: 10.3390/bios13070694] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2023] [Revised: 06/16/2023] [Accepted: 06/28/2023] [Indexed: 07/29/2023]
Abstract
We summarize the application of multivariate optimization for the construction of electrochemical biosensors. The introduction provides an overview of electrochemical biosensing, which is classified into catalytic-based and affinity-based biosensors, and discusses the most recent published works in each category. We then explore the relevance of electrochemical biosensors for food safety analysis, taking into account analytes of different natures. Then, we describe the chemometrics tools used in the construction of electrochemical sensors/biosensors and provide examples from the literature. Finally, we carefully discuss the construction of electrochemical biosensors based on design of experiments, including the advantages, disadvantages, and future perspectives of using multivariate optimization in this field. The discussion section offers a comprehensive analysis of these topics.
Collapse
Affiliation(s)
- Héctor Fernández
- Grupo de Electroanalítica (GEANA), Departamento de Química, Instituto para el Desarrollo Agroindustrial y de la Salud UNRC-CONICET (IDAS), Facultad de Ciencias Exactas, Físico-Químicas y Naturales, Universidad Nacional de Río Cuarto, Río Cuarto 5800, Argentina
| | - María Alicia Zon
- Grupo de Electroanalítica (GEANA), Departamento de Química, Instituto para el Desarrollo Agroindustrial y de la Salud UNRC-CONICET (IDAS), Facultad de Ciencias Exactas, Físico-Químicas y Naturales, Universidad Nacional de Río Cuarto, Río Cuarto 5800, Argentina
| | - Sabrina Antonella Maccio
- Grupo de Electroanalítica (GEANA), Departamento de Química, Instituto para el Desarrollo Agroindustrial y de la Salud UNRC-CONICET (IDAS), Facultad de Ciencias Exactas, Físico-Químicas y Naturales, Universidad Nacional de Río Cuarto, Río Cuarto 5800, Argentina
| | - Rubén Darío Alaníz
- Grupo de Electroanalítica (GEANA), Departamento de Química, Instituto para el Desarrollo Agroindustrial y de la Salud UNRC-CONICET (IDAS), Facultad de Ciencias Exactas, Físico-Químicas y Naturales, Universidad Nacional de Río Cuarto, Río Cuarto 5800, Argentina
| | - Aylen Di Tocco
- Grupo de Electroanalítica (GEANA), Departamento de Química, Instituto para el Desarrollo Agroindustrial y de la Salud UNRC-CONICET (IDAS), Facultad de Ciencias Exactas, Físico-Químicas y Naturales, Universidad Nacional de Río Cuarto, Río Cuarto 5800, Argentina
| | - Roodney Alberto Carrillo Palomino
- Grupo de Electroanalítica (GEANA), Departamento de Química, Instituto para el Desarrollo Agroindustrial y de la Salud UNRC-CONICET (IDAS), Facultad de Ciencias Exactas, Físico-Químicas y Naturales, Universidad Nacional de Río Cuarto, Río Cuarto 5800, Argentina
| | - Jose Alberto Cabas Rodríguez
- Grupo de Electroanalítica (GEANA), Departamento de Química, Instituto para el Desarrollo Agroindustrial y de la Salud UNRC-CONICET (IDAS), Facultad de Ciencias Exactas, Físico-Químicas y Naturales, Universidad Nacional de Río Cuarto, Río Cuarto 5800, Argentina
| | - Adrian Marcelo Granero
- Grupo de Electroanalítica (GEANA), Departamento de Química, Instituto para el Desarrollo Agroindustrial y de la Salud UNRC-CONICET (IDAS), Facultad de Ciencias Exactas, Físico-Químicas y Naturales, Universidad Nacional de Río Cuarto, Río Cuarto 5800, Argentina
| | - Fernando J Arévalo
- Grupo de Electroanalítica (GEANA), Departamento de Química, Instituto para el Desarrollo Agroindustrial y de la Salud UNRC-CONICET (IDAS), Facultad de Ciencias Exactas, Físico-Químicas y Naturales, Universidad Nacional de Río Cuarto, Río Cuarto 5800, Argentina
| | - Sebastian Noel Robledo
- Grupo de Electroanalítica (GEANA), Departamento de Química, Instituto para el Desarrollo Agroindustrial y de la Salud UNRC-CONICET (IDAS), Facultad de Ciencias Exactas, Físico-Químicas y Naturales, Universidad Nacional de Río Cuarto, Río Cuarto 5800, Argentina
- Departamento de Tecnología Química (IDAS), Facultad de Ingeniería, Universidad Nacional de Río Cuarto, Río Cuarto 5800, Argentina
| | - Gastón Darío Pierini
- Grupo de Electroanalítica (GEANA), Departamento de Química, Instituto para el Desarrollo Agroindustrial y de la Salud UNRC-CONICET (IDAS), Facultad de Ciencias Exactas, Físico-Químicas y Naturales, Universidad Nacional de Río Cuarto, Río Cuarto 5800, Argentina
| |
Collapse
|
3
|
Li S, Zeng F, Zheng S, Fan Z, Huang L. Multivariate optimization of characteristic parameters of continuous-flow system with a front buffer tank for industrial reverse osmosis concentrate treatment. CHEMOSPHERE 2023:139078. [PMID: 37268228 DOI: 10.1016/j.chemosphere.2023.139078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/19/2023] [Revised: 05/20/2023] [Accepted: 05/28/2023] [Indexed: 06/04/2023]
Abstract
Industrial reverse osmosis concentrate (ROC) was electrochemically oxidized using a continuous-flow system (CFS) with a front buffer tank. Multivariate optimization including Plackett-Burman (PBD) and central composite design based on response surface method (CCD-RSM) was implemented to investigate the effects of characteristic (e.g., recirculation ratio (R value), ratio of buffer tank and electrolytic zone (RV value)) and routine (e.g., current density (i), inflow linear velocity (v) and electrode spacing (d)) parameters. R, v values and current density significantly influenced chemical oxygen demand (COD) and NH4+-N removal and effluent active chlorine species (ACS) level, while electrode spacing and RV value had negligible effects. High chloride content of industrial ROC facilitated the generation of ACS and subsequent mass transfer, low hydraulic retention time (HRT) of electrolytic cell improved the mass transfer efficiency, and high HRT of buffer tank prolonged the reaction between the pollutants and oxidants. The significance levels of COD removal, energy efficiency, effluent ACS level and toxic byproduct level CCD-RSM models were validated by statistical test results, including higher F value than critical effect value, lower P value than 0.05, low deviation between predicted and observed values, and normal distribution of calculated residuals. The highest pollutant removal was achieved at a high R value, a high current density and a low v value; the highest energy efficiency was achieved at a high R, a low current density and a high v value; the lowest effluent ACS and toxic byproduct levels were achieved at a low R value, a low current density and a high v value. Following the multivariate optimization, the optimum parameters were decided to be v = 1.2 cm h-1, i ≥ 8 mA cm-2, d ≥ 4, RV = 10-20 and R = 1 to achieve better effluent quality (i.e., lower effluent pollutant, ACS and toxic byproduct levels).
Collapse
Affiliation(s)
- Shida Li
- The Key Laboratory of Water and Air Pollution Control of Guangdong Province, South China Institute of Environmental Sciences, Ministry of Ecology and Environment, No. 18 Ruihe Road, Guangzhou, 510530, China
| | - Fantang Zeng
- The Key Laboratory of Water and Air Pollution Control of Guangdong Province, South China Institute of Environmental Sciences, Ministry of Ecology and Environment, No. 18 Ruihe Road, Guangzhou, 510530, China.
| | - Shaokui Zheng
- School of Environment, MOE Key Laboratory of Water and Sediment Sciences/State Key Lab of Water Environment Simulation, Beijing Normal University, Beijing, 100875, China
| | - Zhongya Fan
- The Key Laboratory of Water and Air Pollution Control of Guangdong Province, South China Institute of Environmental Sciences, Ministry of Ecology and Environment, No. 18 Ruihe Road, Guangzhou, 510530, China
| | - Lu Huang
- The Key Laboratory of Water and Air Pollution Control of Guangdong Province, South China Institute of Environmental Sciences, Ministry of Ecology and Environment, No. 18 Ruihe Road, Guangzhou, 510530, China
| |
Collapse
|
4
|
Tarapoulouzi M, Ortone V, Cinti S. Heavy metals detection at chemometrics-powered electrochemical (bio)sensors. Talanta 2022; 244:123410. [DOI: 10.1016/j.talanta.2022.123410] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Revised: 03/21/2022] [Accepted: 03/25/2022] [Indexed: 01/04/2023]
|
5
|
Rotake D, Pratim Goswami P, Govind Singh S. Ultraselective, ultrasensitive, point-of-care electrochemical sensor for detection of Hg(II) ions with electrospun-InZnO nanofibers. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116350] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
6
|
Trends in sensor development toward next-generation point-of-care testing for mercury. Biosens Bioelectron 2021; 183:113228. [PMID: 33862396 DOI: 10.1016/j.bios.2021.113228] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Revised: 04/02/2021] [Accepted: 04/03/2021] [Indexed: 01/01/2023]
Abstract
Mercury is one of the most common heavy metals and a major environmental pollutant that affects ecosystems. Since mercury and its compounds are toxic to humans, even at low concentrations, it is very important to monitor mercury contamination in water and foods. Although conventional mercury detection methods, including inductively coupled plasma mass spectrometry, atomic absorption spectroscopy, and gas chromatography-mass spectrometry, exhibit excellent sensitivity and accuracy, they require operation by an expert in a sophisticated and fully controlled laboratory environment. To overcome these limitations and realize point-of-care testing, many novel methods for direct sample analysis in the field have recently been developed by improving the speed and simplicity of detection. Commonly, these unconventional sensors rely on colorimetric, fluorescence, or electrochemical mechanisms to transduce signals from mercury. In the case of colorimetric and fluorescent sensors, benchtop methods have gradually evolved through technology convergence to give standalone platforms, such as paper-based assays and lab-on-a-chip systems, and portable measurement devices, such as smartphones. Electrochemical sensors that use screen-printed electrodes with carbon or metal nanomaterials or hybrid materials to improve sensitivity and stability also provide promising detection platforms. This review summarizes the current state of sensor platforms for the on-field detection of mercury with a focus on key features and recent developments. Furthermore, trends for next-generation mercury sensors are suggested based on a paradigm shift to the active integration of cutting-edge technologies, such as drones, systems based on artificial intelligence, machine learning, and three-dimensional printing, and high-quality smartphones.
Collapse
|
7
|
Nodehi M, Baghayeri M, Behazin R, Veisi H. Electrochemical aptasensor of bisphenol A constructed based on 3D mesoporous structural SBA-15-Met with a thin layer of gold nanoparticles. Microchem J 2021. [DOI: 10.1016/j.microc.2020.105825] [Citation(s) in RCA: 37] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
8
|
Polatoğlu İ, Aydin L. A new design strategy with stochastic optimization on the preparation of magnetite cross-linked tyrosinase aggregates (MCLTA). Process Biochem 2020. [DOI: 10.1016/j.procbio.2020.08.019] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
9
|
High Performance Zinc Oxide Nanorod-Doped Ion Imprinted Polypyrrole for the Selective Electrosensing of Mercury II Ions. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10197010] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
A biomimetic, ion-imprinted polymer (IIP) was prepared by electropolymerization of pyrrole at the surface of gold electrodes decorated with vertically grown ZnO nanorods. The vertical growth of the nanorods was achieved via an ultrathin aryl monolayer grafted by reduction of diazonium salt precursor. Pyrrole was polymerized in the presence of L-cysteine as chelating agent and Hg2+ (template). Hg2+-imprinted polypyrrole (PPy) was also prepared on a bare gold electrode in order to compare the two methods of sensor design (Au-ZnO-IIP vs. Au-IIP). Non-imprinted PPy was prepared in the same conditions but in the absence of any Hg2+ template. The strategy combining diazonium salt modification and ZnO nanorod decoration of gold electrodes permitted us to increase considerably the specific surface area and thus improve the sensor performance. The limit of detection (LOD) of the designed sensor was ~1 pM, the lowest value ever reported in the literature for gold electrode sensors. The dissociation constants between PPy and Hg2+ were estimated at [Kd1 = (7.89 ± 3.63) mM and Kd2 = (38.10 ± 9.22) pM]. The sensitivity of the designed sensor was found to be 0.692 ± 0.034 μA.pM-1. The Au-ZnO-IIP was found to be highly selective towards Hg2+ compared to cadmium, lead and copper ions. This sensor design strategy could open up new horizons in monitoring toxic heavy metal ions in water and therefore contribute to enhancing environmental quality.
Collapse
|
10
|
Rotake DR, Kumar A, Darji AD, Singh J. Highly selective sensor for the detection of Hg 2+ ions using homocysteine functionalised quartz crystal microbalance with cross-linked pyridinedicarboxylic acid. IET Nanobiotechnol 2020; 14:563-573. [PMID: 33010131 PMCID: PMC8676536 DOI: 10.1049/iet-nbt.2020.0109] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2020] [Revised: 05/18/2020] [Accepted: 06/02/2020] [Indexed: 01/23/2023] Open
Abstract
This study reports an insightful portable vector network analyser (VNA)-based measurement technique for quick and selective detection of Hg2+ ions in nanomolar (nM) range using homocysteine (HCys)-functionalised quartz-crystal-microbalance (QCM) with cross-linked-pyridinedicarboxylic acid (PDCA). The excessive exposure to mercury can cause damage to many human organs, such as the brain, lungs, stomach, and kidneys, etc. Hence, the authors have proposed a portable experimental platform capable of achieving the detection in 20-30 min with a limit of detection (LOD) 0.1 ppb (0.498 nM) and a better dynamic range (0.498 nM-6.74 mM), which perfectly describes its excellent performance over other reported techniques. The detection time for various laboratory-based techniques is generally 12-24 h. The proposed method used the benefits of thin-film, nanoparticles (NPs), and QCM-based technology to overcome the limitation of NPs-based technique and have LOD of 0.1 ppb (0.1 μg/l) for selective Hg2+ ions detection which is many times less than the World Health Organization limit of 6 μg/l. The main advantage of the proposed QCM-based platform is its portability, excellent repeatability, millilitre sample volume requirement, and easy process flow, which makes it suitable as an early warning system for selective detection of mercury ions without any costly measuring instruments.
Collapse
Affiliation(s)
- Dinesh Ramkrushna Rotake
- Electronics Engineering Department, Sardar Vallabhbhai National Institute of Technology, Surat, Gujarat, India.
| | - Ajay Kumar
- Smart Sensors Area, CSIR-Central Electronics Engineering Research Institute, Pilani-333031, Rajasthan, India
| | - Anand D Darji
- Electronics Engineering Department, Sardar Vallabhbhai National Institute of Technology, Surat, Gujarat, India
| | - Jitendra Singh
- Smart Sensors Area, CSIR-Central Electronics Engineering Research Institute, Pilani-333031, Rajasthan, India
| |
Collapse
|
11
|
Abad-Gil L, Gismera MJ, Sevilla MT, Procopio JR. Methylisothiazolinone response on disposable electrochemical platforms modified with carbon, nickel or gold-based nanomaterials. Mikrochim Acta 2020; 187:199. [PMID: 32130541 DOI: 10.1007/s00604-020-4157-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2019] [Accepted: 02/11/2020] [Indexed: 12/11/2022]
Abstract
Screen-printed carbon electrodes (SPCE) were modified with nanocomposite membranes based on polystyrene sulfonate (PSS) or poly(diallyldimethylammonium) (PDDA) matrices and different nanomaterials. Carbon nano-powders (CnP), carbon nano-fibers (CnF) and multi-walled carbon nano-tubes (MWCNTs) were incorporated on PSS matrix. Nickel was incorporated by ion exchange in PSS-CnP composite membranes. Gold nanoparticles (AuNp) were photochemically and electrochemically synthesised and introduced into PDDA membranes. The electrochemical behaviour of methylisothiazolinone (MIT) using these modified electrodes was studied by cyclic voltammetry in 0.1 mol L-1 NaOH. No electrochemical response is obtained on PSS-nanocarbon transducers at the assayed conditions. The nickel-based transducers allow the MIT identification but not quantification. Using AuNp-based electrochemical transducers, it is observed that in presence of MIT, the electron transfer for AuNp reduction is inhibited, and an oxidation peak appears at + 0.45 V, indicating an interaction between MIT and AuNp on the electrode surface. These facts support the usefulness of the AuNp-based electrodes for the determination of MIT. The intensity of the anodic peak observed at + 0.45 V vs. Ag/AgCl was used as analytical signal for MIT determination. A linear relationship between anodic peak current and MIT concentration is observed in the range 8.7 to 36 mg L-1 using the transducer prepared by incorporating gold into the PDDA membrane by ion exchange and synthesising AuNp electrochemically. For this electrode, the limit of detection is 2.6 mg L-1 and the reproducibility, expressed as relative standard deviation (RSD), is lower than 7%. Graphical abstractSchematic representation of the preparation of gold nanoparticles (AuNp) and poly(diallyldimethylammonium) (PDDA)-based platforms and methylisothiazolinone (MIT) electrochemical response on these nanostructured platforms.
Collapse
Affiliation(s)
- Lucía Abad-Gil
- Department of Analytical Chemistry and Instrumental Analysis, Sciences Faculty, Autonoma University of Madrid, Avda. Francisco Tomas y Valiente, 7, E-28049, Madrid, Spain.
| | - María Jesús Gismera
- Department of Analytical Chemistry and Instrumental Analysis, Sciences Faculty, Autonoma University of Madrid, Avda. Francisco Tomas y Valiente, 7, E-28049, Madrid, Spain
| | - María Teresa Sevilla
- Department of Analytical Chemistry and Instrumental Analysis, Sciences Faculty, Autonoma University of Madrid, Avda. Francisco Tomas y Valiente, 7, E-28049, Madrid, Spain
| | - Jesús R Procopio
- Department of Analytical Chemistry and Instrumental Analysis, Sciences Faculty, Autonoma University of Madrid, Avda. Francisco Tomas y Valiente, 7, E-28049, Madrid, Spain
| |
Collapse
|
12
|
Affiliation(s)
- İlker Polatoğlu
- Bioengineering Department, Manisa Celal Bayar University, Manisa, Turkey
| | - Levent Aydın
- Department of Mechanical Engineering, Izmir Katip Çelebi University, Cigli, Izmir, Turkey
| | | | - Sibel Özer
- Bioengineering Department, Manisa Celal Bayar University, Manisa, Turkey
| |
Collapse
|
13
|
Han J, Fu R, Jin C, Li Z, Wang M, Yu P, Xie Y. Highly sensitive detection of trace Hg2+ via PdNPs/g-C3N4 nanosheet-modified electrodes using DPV. Microchem J 2020. [DOI: 10.1016/j.microc.2019.104356] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
14
|
Agarose dispersed liquid crystals as a soft sensing platform for detecting mercuric ions in water. RESEARCH ON CHEMICAL INTERMEDIATES 2019. [DOI: 10.1007/s11164-019-03978-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
15
|
Affiliation(s)
- Eden E. L. Tanner
- University of Oxford, Department of Chemistry, Physical and Theoretical Chemistry Laboratory; Oxford University; South Parks Road, Oxford OX1 3QZ United Kingdom
- Now at the School of Engineering & Applied Sciences; Harvard University; Cambridge, MA USA
| | - Richard G. Compton
- University of Oxford, Department of Chemistry, Physical and Theoretical Chemistry Laboratory; Oxford University; South Parks Road, Oxford OX1 3QZ United Kingdom
| |
Collapse
|
16
|
Recent Studies on the Speciation and Determination of Mercury in Different Environmental Matrices Using Various Analytical Techniques. Int J Anal Chem 2017; 2017:3624015. [PMID: 29348750 PMCID: PMC5733771 DOI: 10.1155/2017/3624015] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2017] [Accepted: 10/26/2017] [Indexed: 11/25/2022] Open
Abstract
This paper reviews the current research on the speciation and determination of mercury by various analytical techniques, including the atomic absorption spectrometry (AAS), voltammetry, inductively coupled plasma optical emission spectrometry (ICP-OES), ICP-mass spectrometry (MS), atomic fluorescence spectrometry (AFS), spectrophotometry, spectrofluorometry, and high performance liquid chromatography (HPLC). Approximately 96 research papers on the speciation and determination of mercury by various analytical instruments published in international journals since 2015 were reviewed. All analytical parameters, including the limits of detection, linearity range, quality assurance and control, applicability, and interfering ions, evaluated in the reviewed articles were tabulated. In this review, we found a lack of information in speciation studies of mercury in recent years. Another important conclusion from this review was that there were few studies regarding the concentration of mercury in the atmosphere.
Collapse
|
17
|
Suherman AL, Tanner EE, Compton RG. Recent developments in inorganic Hg 2+ detection by voltammetry. Trends Analyt Chem 2017. [DOI: 10.1016/j.trac.2017.07.020] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
18
|
Zhu P, Tian W, Cheng N, Huang K, Luo Y, Xu W. Ultra-sensitive “turn-on” detection method for Hg2+ based on mispairing biosensor and emulsion PCR. Talanta 2016; 155:168-74. [DOI: 10.1016/j.talanta.2016.04.026] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2016] [Revised: 04/10/2016] [Accepted: 04/11/2016] [Indexed: 01/16/2023]
|
19
|
María-Hormigos R, Gismera MJ, Procopio JR, Sevilla MT. Disposable screen-printed electrode modified with bismuth–PSS composites as high sensitive sensor for cadmium and lead determination. J Electroanal Chem (Lausanne) 2016. [DOI: 10.1016/j.jelechem.2016.02.025] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
|