Application of Fabric Phase Sorptive Extraction (FPSE) Engaged to Tandem LC-MS/MS for Quantification of Brorphine in Oral Fluid. J Xenobiot 2022; 12:356-364. [PMID: 36547469 PMCID: PMC9782742 DOI: 10.3390/jox12040025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 11/20/2022] [Accepted: 11/22/2022] [Indexed: 11/29/2022] Open
Abstract
Brorphine (1-[1-[1-(4-bromophenyl) ethyl]-piperidin-4-yl]-1,3-dihydro-2H-benzo [d]imidazol-2-one) is one of the most recent novel synthetic opioids (NSOs) on the novel psychoactive substances (NPSs) market, involved in over 100 deaths in 2020. Brorphine is a substituted piperidine-benzimidazolone analogue that retains structural similarities to fentanyl, acting as a full agonist at the μ-opioid receptor. Oral Fluid (OF) is an alternative matrix, frequently analyzed for the detection of NPS. Fabric phase sorptive extraction (FPSE) is a superior, green-sample -preparation technology recently applied for drug analysis. This contribution presents the development and validation of a method, based on the application of FPSE and liquid chromatography-tandem mass spectrometry (LC-MS/MS), to determine/quantitate brorphine in OF. The method's linearity ranged between 0.05 and 50 ng/mL (R2 = 0.9993), the bias ranged between 12.0 and 16.8%, and inter- and intra-day precisions ranged between 6.4 and 9.9%. Accuracy and extraction efficiency lied between 65 and 75%. LOD/LOQ were 0.015 ng/mL/0.05 ng/mL. Analyte's post-preparative stability was higher than 95%, while no matrix interferences and carryover between runs were observed. This is the first report introducing the application of FPSE for NPS determination, specifically, the quantification of brorphine in OF, thereby presenting a simple, rapid, sensitive, specific, effective, and reliable procedure engaged to LC-MS/MS that is suitable for routine application and the analysis of more NPSs.
Collapse
|
2
|
Wan F, Liu S, Wang L, Si S. A novel salting-out extraction system for determination of ethylene glycol and diethylene glycol in liquid samples followed by GC-FID. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107491] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
3
|
Shao P, Liu L, Yu J, Lin Y, Gao H, Chen H, Sun P. An overview of intelligent freshness indicator packaging for food quality and safety monitoring. Trends Food Sci Technol 2021. [DOI: 10.1016/j.tifs.2021.10.012] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
4
|
Ubeda S, Aznar M, Nerín C, Kabir A. Fabric phase sorptive extraction for specific migration analysis of oligomers from biopolymers. Talanta 2021; 233:122603. [PMID: 34215091 DOI: 10.1016/j.talanta.2021.122603] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2021] [Revised: 06/07/2021] [Accepted: 06/08/2021] [Indexed: 11/29/2022]
Abstract
Oligomers are potential migrants from polymers or biopolymers intended to food packaging and they have to be under control. In order to comply with European regulation 10/2011, their concentration in migration must be below 0.01 μg g-1. In this work, fabric phase sorptive extraction (FPSE) was explored as an effective method for extraction and pre-concentration of oligomers migrated from a blend PLA-polyester material. Both food simulant B (3% acetic acid) and juice, as real food, were used for migration experiments. The parameters of FPSE were optimized and the analysis was done by UHPLC-QTOF and UHPLC-QqQ. A total of 21 oligomers were identified, 9 of them coming from PLA and 12 oligomers from the polyester part. These oligomers were formed by adipic acid (AA), phthalic acid (PA) and/or butanediol (BD), ten were cyclic and 11 were linear molecules. Using the optimized FPSE procedure in 3% acetic acid as food simulant, it was possible to identify 3 new compounds that were not detected by direct injection of the simulant into UHPLC-QTOF. In addition, 2 extra compounds, cyclic PA-BD4-AA3 and cyclic PA2-BD3-AA, were only identified in juice samples after FPSE extraction. Besides, in order to quantify the compounds identified, an isolation procedure for PLA oligomers was carried out. Two oligomers were isolated: cyclic (LA)6 and linear HO-(LA)4-H, both with a purity higher than 90% (LA: lactic acid). The highest concentration value was found for the cyclic oligomer [AA-BD]2, that showed 22.63 μg g-1 in 3% acetic acid and 19.64 μg g-1 in juice. The concentration of the total amount of remaining oligomers was below 7.56 μg g-1 in 3% acetic acid as well as in juice.
Collapse
Affiliation(s)
- Sara Ubeda
- Department of Analytical Chemistry, I3A, EINA, University of Zaragoza, Madre de Lune 3, 50018, Zaragoza, Spain
| | - Margarita Aznar
- Department of Analytical Chemistry, I3A, EINA, University of Zaragoza, Madre de Lune 3, 50018, Zaragoza, Spain
| | - Cristina Nerín
- Department of Analytical Chemistry, I3A, EINA, University of Zaragoza, Madre de Lune 3, 50018, Zaragoza, Spain.
| | - Abuzar Kabir
- Department of Chemistry and Biochemistry, Florida International University, 11200 SW 8th Street, Miami, Fl, 33199, USA
| |
Collapse
|
5
|
Kato LS, Conte-Junior CA. Safety of Plastic Food Packaging: The Challenges about Non-Intentionally Added Substances (NIAS) Discovery, Identification and Risk Assessment. Polymers (Basel) 2021; 13:2077. [PMID: 34202594 PMCID: PMC8271870 DOI: 10.3390/polym13132077] [Citation(s) in RCA: 37] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Revised: 05/23/2021] [Accepted: 05/24/2021] [Indexed: 11/16/2022] Open
Abstract
Several food contact materials (FCMs) contain non-intentionally added substances (NIAS), and most of the substances that migrate from plastic food packaging are unknown. This review aimed to situate the main challenges involving unknown NIAS in plastic food packaging in terms of identification, migration tests, prediction, sample preparation, determination methods and risk assessment trials. Most studies have identified NIAS in plastic materials as polyurethane adhesives (PU), polyethylene terephthalate (PET), polyester coatings, polypropylene materials (PP), multilayers materials, plastic films, polyvinyl chloride (PVC), recycled materials, high-density polyethylene (HDPE) and low-density polyethylene (LDPE). Degradation products are almost the primary source of NIAS in plastic FCMs, most from antioxidants as Irganox 1010 and Irgafos 168, following by oligomers and side reaction products. The NIAS assessment in plastics FCMs is usually made by migration tests under worst-case conditions using food simulants. For predicted NIAS, targeted analytical methods are applied using GC-MS based methods for volatile NIAS and GC-MS and LC-MS based methods for semi- and non-volatile NIAS; non-targeted methods to analyze unknown NIAS in plastic FCMs are applied using GC and LC techniques combined with QTOF mass spectrometry (HRMS). In terms of NIAS risk assessment and prioritization, the threshold of toxicological concern (TTC) concept is the most applied tool for risk assessment. Bioassays with sensitive analytical techniques seem to be an efficient method to identify NIAS and their hazard to human exposure; the combination of genotoxicity testing with analytical chemistry could allow the Cramer class III TTC application to prioritize unknown NIAS. The scientific justification for implementing a molecular weight-based cut-off (<1000 Da) in the risk assessment of FCMs should be reevaluated. Although official guides and opinions are being issued on the subject, the whole chain's alignment is needed, and more specific legislation on the steps to follow to get along with NIAS.
Collapse
Affiliation(s)
- Lilian Seiko Kato
- Center for Food Analysis (NAL), Technological Development Support Laboratory (LADETEC), Federal University of Rio de Janeiro (UFRJ), Cidade Universitária, Rio de Janeiro 21941-598, Brazil;
- Laboratory of Advanced Analysis in Biochemistry and Molecular Biology, (LAABBM), Department of Biochemistry, Federal University of Rio de Janeiro (UFRJ), Cidade Universitária, Rio de Janeiro 21941-909, Brazil
| | - Carlos A. Conte-Junior
- Center for Food Analysis (NAL), Technological Development Support Laboratory (LADETEC), Federal University of Rio de Janeiro (UFRJ), Cidade Universitária, Rio de Janeiro 21941-598, Brazil;
- Laboratory of Advanced Analysis in Biochemistry and Molecular Biology, (LAABBM), Department of Biochemistry, Federal University of Rio de Janeiro (UFRJ), Cidade Universitária, Rio de Janeiro 21941-909, Brazil
- Graduate Program in Food Science (PPGCAL), Institute of Chemistry (IQ), Federal University of Rio de Janeiro (UFRJ), Cidade Universitária, Rio de Janeiro 21941-909, Brazil
- Graduate Program in Veterinary Hygiene (PPGHV), Faculty of Veterinary Medicine, Fluminense Federal University (UFF), Vital Brazil Filho, Niterói 24220-000, Brazil
- Graduate Program in Sanitary Surveillance (PPGVS), National Institute of Health Quality Control (INCQS), Oswaldo Cruz Foundation (FIOCRUZ), Rio de Janeiro 21040-900, Brazil
- Graduate Program in Chemistry (PGQu), Institute of Chemistry (IQ), Federal University of Rio de Janeiro (UFRJ), Cidade Universitária, Rio de Janeiro 21941-909, Brazil
| |
Collapse
|
6
|
Tsochatzis ED, Lopes JA, Gika H, Dalsgaard TK, Theodoridis G. A fast SALLE GC-MS/MS multi-analyte method for the determination of 75 food packaging substances in food simulants. Food Chem 2021; 361:129998. [PMID: 34082389 DOI: 10.1016/j.foodchem.2021.129998] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Revised: 04/28/2021] [Accepted: 04/29/2021] [Indexed: 11/19/2022]
Abstract
A simple and fast method was developed for the simultaneous determination of 75 plastic food contact material (FCM) in liquid food simulants, at levels of a few ng g-1. The method employs an optimised salt-assisted liquid-liquid extraction for all EU-regulated ethanol/H2O food simulants, in the presence of 10% NaCl (simulants A and C) or 5% NaCl (simulant D1), and dichloromethane as the extracting solvent. Gas chromatography with triple-quad MS operating in multiple reaction monitoring acquisition was used, applying isotope dilution with selected deuterated compounds. Adequate sensitivity was demonstrated for all analytes. The results also showed sufficient accuracy for the majority of substances, with recoveries of 70-120% and repeatability (expressed as relative standard deviations, RSDs) smaller than 15%. The method was applied to the analysis of FCM multilayer items after undergoing migration testing according to the specifications of the current EU legislation in force.
Collapse
Affiliation(s)
- Emmanouil D Tsochatzis
- Department of Food Science, Centre of Innovative Food Research (iFood), Aarhus University, Agro Food Park 48, 8200 Aarhus N, Denmark.
| | | | - Helen Gika
- FoodOmicsGR Research Infrastructure, AUTh Node, Center for Interdisciplinary Research and Innovation (CIRI-AUTH), Balkan Center B1.4 10th Km Thessaloniki-Thermi Rd P.O. Box 8318 GR, 57001 Thessaloniki, Greece; Biomic AUTh, Center for Interdisciplinary Research and Innovation (CIRI-AUTH), Balkan Center B1.4, 10th Km Thessaloniki-Thermi Rd, P.O. Box 8318 GR, 57001 Thessaloniki, Greece; Department of Medicine, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| | - Trine Kastrup Dalsgaard
- Department of Food Science, Centre of Innovative Food Research (iFood), Aarhus University, Agro Food Park 48, 8200 Aarhus N, Denmark
| | - Georgios Theodoridis
- FoodOmicsGR Research Infrastructure, AUTh Node, Center for Interdisciplinary Research and Innovation (CIRI-AUTH), Balkan Center B1.4 10th Km Thessaloniki-Thermi Rd P.O. Box 8318 GR, 57001 Thessaloniki, Greece; Biomic AUTh, Center for Interdisciplinary Research and Innovation (CIRI-AUTH), Balkan Center B1.4, 10th Km Thessaloniki-Thermi Rd, P.O. Box 8318 GR, 57001 Thessaloniki, Greece; Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| |
Collapse
|
7
|
Green bioanalytical sample preparation: fabric phase sorptive extraction. Bioanalysis 2021; 13:693-710. [PMID: 33890507 DOI: 10.4155/bio-2021-0004] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Fabric phase sorptive extraction (FPSE) is a recently introduced sample preparation technique that has attracted substantial interest of the scientific community dealing with bioanalysis. This technique is based on a permeable and flexible substrate made of fabric, coated with a sol-gel organic-inorganic sorbent. Among the benefits of FPSE are its tunable selectivity, adjustable porosity, minimized sample preparation workflow, substantially reduced organic solvent consumption, rapid extraction kinetics and superior extraction efficiency, many of which are well-known criteria for Green Analytical Chemistry. As such, FPSE has established itself as a leading green sample preparation technology of 21st century. In this review, we discuss the principal steps for the development of an FPSE method, the main method optimization strategies, as well as the applications of FPSE in bioanalysis for the extraction of a wide range of analytes (e.g., estrogens, benzodiazepines, androgens and progestogens, penicillins, anti-inflammatory drugs, parabens etc.).
Collapse
|
8
|
Vasile C, Baican M. Progresses in Food Packaging, Food Quality, and Safety-Controlled-Release Antioxidant and/or Antimicrobial Packaging. Molecules 2021; 26:1263. [PMID: 33652755 PMCID: PMC7956554 DOI: 10.3390/molecules26051263] [Citation(s) in RCA: 69] [Impact Index Per Article: 23.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2021] [Revised: 02/10/2021] [Accepted: 02/17/2021] [Indexed: 02/07/2023] Open
Abstract
Food packaging is designed to protect foods, to provide required information about the food, and to make food handling convenient for distribution to consumers. Packaging has a crucial role in the process of food quality, safety, and shelf-life extension. Possible interactions between food and packaging are important in what is concerning food quality and safety. This review tries to offer a picture of the most important types of active packaging emphasizing the controlled/target release antimicrobial and/or antioxidant packaging including system design, different methods of polymer matrix modification, and processing. The testing methods for the appreciation of the performance of active food packaging, as well as mechanisms and kinetics implied in active compounds release, are summarized. During the last years, many fast advancements in packaging technology appeared, including intelligent or smart packaging (IOSP), (i.e., time-temperature indicators (TTIs), gas indicators, radiofrequency identification (RFID), and others). Legislation is also discussed.
Collapse
Affiliation(s)
- Cornelia Vasile
- “P. Poni” Institute of Macromolecular Chemistry, 41 A Grigore Ghica Voda Alley, 70487 Iasi, Romania
| | - Mihaela Baican
- “Grigore T. Popa” Medicine and Pharmacy University, 16 University Street, 700115 Iaşi, Romania;
| |
Collapse
|
9
|
Kabir A, Samanidou V. Fabric Phase Sorptive Extraction: A Paradigm Shift Approach in Analytical and Bioanalytical Sample Preparation. Molecules 2021; 26:865. [PMID: 33562079 PMCID: PMC7915638 DOI: 10.3390/molecules26040865] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Revised: 02/01/2021] [Accepted: 02/04/2021] [Indexed: 12/18/2022] Open
Abstract
Fabric phase sorptive extraction (FPSE) is an evolutionary sample preparation approach which was introduced in 2014, meeting all green analytical chemistry (GAC) requirements by implementing a natural or synthetic permeable and flexible fabric substrate to host a chemically coated sol-gel organic-inorganic hybrid sorbent in the form of an ultra-thin coating. This construction results in a versatile, fast, and sensitive micro-extraction device. The user-friendly FPSE membrane allows direct extraction of analytes with no sample modification, thus eliminating/minimizing the sample pre-treatment steps, which are not only time consuming, but are also considered the primary source of major analyte loss. Sol-gel sorbent-coated FPSE membranes possess high chemical, solvent, and thermal stability due to the strong covalent bonding between the fabric substrate and the sol-gel sorbent coating. Subsequent to the extraction on FPSE membrane, a wide range of organic solvents can be used in a small volume to exhaustively back-extract the analytes after FPSE process, leading to a high preconcentration factor. In most cases, no solvent evaporation and sample reconstitution are necessary. In addition to the extensive simplification of the sample preparation workflow, FPSE has also innovatively combined the extraction principle of two major, yet competing sample preparation techniques: solid phase extraction (SPE) with its characteristic exhaustive extraction, and solid phase microextraction (SPME) with its characteristic equilibrium driven extraction mechanism. Furthermore, FPSE has offered the most comprehensive cache of sorbent chemistry by successfully combining almost all of the sorbents traditionally used exclusively in either SPE or in SPME. FPSE is the first sample preparation technique to exploit the substrate surface chemistry that complements the overall selectivity and the extraction efficiency of the device. As such, FPSE indeed represents a paradigm shift approach in analytical/bioanalytical sample preparation. Furthermore, an FPSE membrane can be used as an SPME fiber or as an SPE disk for sample preparation, owing to its special geometric advantage. So far, FPSE has overwhelmingly attracted the interest of the separation scientist community, and many analytical scientists have been developing new methodologies by implementing this cutting-edge technique for the extraction and determination of many analytes at their trace and ultra-trace level concentrations in environmental samples as well as in food, pharmaceutical, and biological samples. FPSE offers a total sample preparation solution by providing neutral, cation exchanger, anion exchanger, mixed mode cation exchanger, mixed mode anion exchanger, zwitterionic, and mixed mode zwitterionic sorbents to deal with any analyte regardless of its polarity, ionic state, or the sample matrix where it resides. Herein we present the theoretical background, synthesis, mechanisms of extraction and desorption, the types of sorbents, and the main applications of FPSE so far according to different sample categories, and to briefly show the progress, advantages, and the main principles of the proposed technique.
Collapse
Affiliation(s)
- Abuzar Kabir
- Department of Chemistry and Biochemistry, International Forensic Research Institute, Florida International University, 11200 SW 8th St, Miami, FL 33199, USA;
| | - Victoria Samanidou
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| |
Collapse
|
10
|
Locatelli M, Tartaglia A, Ulusoy HI, Ulusoy S, Savini F, Rossi S, Santavenere F, Merone GM, Bassotti E, D'Ovidio C, Rosato E, Furton KG, Kabir A. Fabric-Phase Sorptive Membrane Array As a Noninvasive In Vivo Sampling Device For Human Exposure To Different Compounds. Anal Chem 2021; 93:1957-1961. [PMID: 33470800 PMCID: PMC7877698 DOI: 10.1021/acs.analchem.0c04663] [Citation(s) in RCA: 41] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
![]()
This
study introduces an innovative device for the noninvasive
sampling and chromatographic analysis of different compounds present
in exhaled breath aerosol (EBA). The new sampling device, especially
in light of the recent COVID-19 pandemic that forced many countries
to impose mandatory facemasks, allows an easy monitoring of the subject’s
exposure to different compounds they may come in contact with, actively
or passively. The project combines the advantages of a fabric-phase
sorptive membrane (FPSM) as an in vivo sampling device
with a validated LC-MS/MS screening procedure able to monitor more
than 739 chemicals with an overall analysis time of 18 min. The project
involves the noninvasive in vivo sampling of the
EBA using an FPSM array inserted inside an FFP2 mask. The study involved
15 healthy volunteers, and no restrictions were imposed during or
prior to the sampling process regarding the consumption of drinks,
food, or drugs. The FPSM array-LC-MS/MS approach allowed us to effectively
exploit the advantages of the two complementary procedures (the convenient
sampling by an FPSM array and the rapid analysis by LC-MS/MS), obtaining
a powerful and green tool to carry out rapid screening analyses for
human exposure to different compounds. The flexible fabric substrate,
the sponge-like porous architecture of the high-efficiency sol–gel
sorbent coating, the availability of a large cache of sorbent coatings,
including polar, nonpolar, mixed mode, and zwitterionic phases, the
easy installation into the facemask, and the possibility of sampling
without interrupting regular activities provide FPSMs unparalleled
advantages over other sampling techniques, and their applications
are expected to expand to many other clinical or toxicological studies.
Collapse
Affiliation(s)
- Marcello Locatelli
- Department of Pharmacy, University of Chieti-Pescara "G. d'Annunzio", Via dei Vestini 31, Chieti 66100, Italy
| | - Angela Tartaglia
- Department of Pharmacy, University of Chieti-Pescara "G. d'Annunzio", Via dei Vestini 31, Chieti 66100, Italy
| | - Halil I Ulusoy
- Department of Analytical Chemistry, Faculty of Pharmacy, Cumhuriyet University, Sivas 58140, Turkey
| | - Songul Ulusoy
- Department of Chemistry, Faculty of Science, Cumhuriyet University, Sivas 58140, Turkey
| | - Fabio Savini
- Pharmatoxicology Laboratory, Santo Spirito Hospital, Via Fonte Romana 8, Pescara 65124, Italy
| | - Sandra Rossi
- Pharmatoxicology Laboratory, Santo Spirito Hospital, Via Fonte Romana 8, Pescara 65124, Italy
| | - Francesco Santavenere
- Pharmatoxicology Laboratory, Santo Spirito Hospital, Via Fonte Romana 8, Pescara 65124, Italy
| | - Giuseppe M Merone
- Department of Neuroscience, Imaging and Clinical Sciences, University of Chieti-Pescara "G. d'Annunzio", Chieti 66100, Italy
| | - Elisa Bassotti
- R&D Department Eureka Lab Division, Chiaravalle 60033, Italy
| | - Cristian D'Ovidio
- Department of Medicine and Aging Sciences, Section of Legal Medicine, University of Chieti-Pescara "G. d'Annunzio", Chieti 66100, Italy
| | - Enrica Rosato
- Department of Pharmacy, University of Chieti-Pescara "G. d'Annunzio", Via dei Vestini 31, Chieti 66100, Italy
| | - Kenneth G Furton
- Department of Chemistry and Biochemistry, Florida International University, 11200 SW Eighth Street, Miami, Florida 33199, United States
| | - Abuzar Kabir
- Department of Chemistry and Biochemistry, Florida International University, 11200 SW Eighth Street, Miami, Florida 33199, United States
| |
Collapse
|
11
|
Agadellis E, Tartaglia A, Locatelli M, Kabir A, Furton KG, Samanidou V. Mixed-mode fabric phase sorptive extraction of multiple tetracycline residues from milk samples prior to high performance liquid chromatography-ultraviolet analysis. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105437] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
12
|
Rigkos G, Alampanos V, Kabir A, Furton KG, Roje Ž, Vrček IV, Panderi I, Samanidou V. An improved fabric‐phase sorptive extraction protocol for the determination of seven parabens in human urine by HPLC–DAD. Biomed Chromatogr 2020; 35:e4974. [DOI: 10.1002/bmc.4974] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2020] [Revised: 08/14/2020] [Accepted: 08/21/2020] [Indexed: 12/19/2022]
Affiliation(s)
- Georgios Rigkos
- Laboratory of Analytical Chemistry, Department of Chemistry Aristotle University of Thessaloniki Thessaloniki Greece
| | - Vasileios Alampanos
- Laboratory of Analytical Chemistry, Department of Chemistry Aristotle University of Thessaloniki Thessaloniki Greece
| | - Abuzar Kabir
- International Forensic Research Institute, Department of Chemistry and Biochemistry Florida International University Miami FL USA
| | - Kenneth G. Furton
- International Forensic Research Institute, Department of Chemistry and Biochemistry Florida International University Miami FL USA
| | - Željka Roje
- Department for Plastic, Reconstructive and Aesthetic Surgery University Hospital Dubrava Zagreb Croatia
| | | | - Irene Panderi
- Laboratory of Pharmaceutical Analysis, Division of Pharmaceutical Chemistry, Faculty of Pharmacy National and Kapodistrtian University of Athens Panepistimiopolis‐Zografou Athens GR Greece
| | - Victoria Samanidou
- Laboratory of Analytical Chemistry, Department of Chemistry Aristotle University of Thessaloniki Thessaloniki Greece
| |
Collapse
|
13
|
Investigating the Utility of Fabric Phase Sorptive Extraction and HPLC-UV-Vis/DAD to Determine Antidepressant Drugs in Environmental Aqueous Samples. SEPARATIONS 2020. [DOI: 10.3390/separations7030039] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Abstract
Depression is considered to be one of the most prevalent mental disorders in humans. Antidepressant drugs are released in large concentrations and cause adverse effects on the environment and/or human health. Fabric Phase Sorptive Extraction (FPSE), a contemporary solid sorbent-handling technique, is a quick, sensitive, and simple analytical process. This paper describes a micro-extraction FPSE procedure coupled with High-Performance Liquid-Chromatography–Photodiode Array Detection (FPSE-HPLC–DAD) for the simultaneous extraction and analysis of five antidepressants, namely citalopram, clozapine, mirtazapine, bupropion and sertraline. Three fabric media (Whatman Cellulose filter, Whatman Microfiber Glass filter and Polylactic acid disks) and two different sol–gel sorbents (polyethylene glycol (PEG 300), alongside poly(ethylene glycol)-block-poly(propylene glycol)-block-poly(ethylene glycol) (PEG-PPG-PEG 5.800)) were tested. The best FPSE device was observed to be the microfiber glass filter coated with PEG 300 sol–gel sorbent. In addition, the parameters that affect the efficiency of the process (FPSE media and sorbents, sample pH, extraction time, elution time, etc.) were optimized. The proposed methodology displays a linear range with absolute recovery values higher than 60%, RSD% of less than 13% and LOQs in the range between 1.9–10.7 μg·L−1. Finally, the method was applied in hospital and urban effluents and lake water samples, but none of the analytes were detected.
Collapse
|
14
|
Tsochatzis ED, Alberto Lopes J, Hoekstra E, Emons H. Development and validation of a multi-analyte GC-MS method for the determination of 84 substances from plastic food contact materials. Anal Bioanal Chem 2020; 412:5419-5434. [PMID: 32583214 PMCID: PMC7387375 DOI: 10.1007/s00216-020-02758-7] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Revised: 05/28/2020] [Accepted: 06/04/2020] [Indexed: 12/20/2022]
Abstract
Chemical substances shall not migrate from food contact materials (FCM) at levels that are potentially harmful for the consumers. Each of the current analytical methods applied to verify the migration of substances from FCM covers only one or few substances. There is a very limited number of publications on the development of analytical methods allowing the simultaneous determination of several classes of FCM substances, and almost none of them reported methods entirely dedicated to the ones in the positive list of Commission Regulation (EU) No. 10/2011 for plastic FCMs. Therefore, a simple, sensitive and reliable multi-analyte method was developed for the analysis of FCM substances in food simulants. It employs an optimised liquid-liquid extraction with dichloromethane as extraction solvent in the presence of 10% m/v NaCl, followed by quantitative analysis with gas chromatography coupled to mass spectrometry (GC-MS). A combination of total ion chromatograms (TICs) and extracted ion chromatograms (EICs) was used. The optimisation and validation of the method have been carried out according to current international guidelines. Adequate sensitivity was demonstrated in the selected concentration ranges for most of the analytes, with limits of quantification (LOQs) at least three times lower than the legislative limit, when existing. The results showed that the method is sufficiently accurate for the majority of substances, with recoveries between 70 and 115% and relative standard deviations (RSDs) smaller than 20% at three concentration levels. The method was applied to the analysis of some FCM multilayers. The method allows, for the first time, the simultaneous quantification of 84 FCM substances in two of the official food simulants (A and C) at levels of a few ng g−1. Graphical abstract ![]()
Collapse
Affiliation(s)
| | - Joao Alberto Lopes
- European Commission, Joint Research Centre (JRC), Retieseweg 111, 2440, Geel, Belgium.
| | - Eddo Hoekstra
- European Commission, Joint Research Centre (JRC), Via E. Fermi 2749, 21027, Ispra, Italy
| | - Hendrik Emons
- European Commission, Joint Research Centre (JRC), Retieseweg 111, 2440, Geel, Belgium
| |
Collapse
|
15
|
Manousi N, Zachariadis GA. Recent Advances in the Extraction of Polycyclic Aromatic Hydrocarbons from Environmental Samples. Molecules 2020; 25:E2182. [PMID: 32392764 PMCID: PMC7249015 DOI: 10.3390/molecules25092182] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Revised: 05/01/2020] [Accepted: 05/04/2020] [Indexed: 02/07/2023] Open
Abstract
Polycyclic aromatic hydrocarbons (PAHs) comprise a group of chemical compounds consisting of two or more fused benzene rings. PAHs exhibit hydrophobicity and low water solubility, while some of their members are toxic substances resistant to degradation. Due to their low levels in environmental matrices, a preconcentration step is usually required for their determination. Nowadays, there is a wide variety of sample preparation techniques, including micro-extraction techniques (e.g., solid-phase microextraction and liquid phase microextraction) and miniaturized extraction techniques (e.g., dispersive solid-phase extraction, magnetic solid-phase extraction, stir bar sorptive extraction, fabric phase sorptive extraction etc.). Compared to the conventional sample preparation techniques, these novel techniques show some benefits, including reduced organic solvent consumption, while they are time and cost efficient. A plethora of adsorbents, such as metal-organic frameworks, carbon-based materials and molecularly imprinted polymers, have been successfully coupled with a wide variety of extraction techniques. This review focuses on the recent advances in the extraction techniques of PAHs from environmental matrices, utilizing novel sample preparation approaches and adsorbents.
Collapse
Affiliation(s)
- Natalia Manousi
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| | - George A. Zachariadis
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| |
Collapse
|
16
|
Jalili V, Barkhordari A, Ghiasvand A. Bioanalytical Applications of Microextraction Techniques: A Review of Reviews. Chromatographia 2020. [DOI: 10.1007/s10337-020-03884-1] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
17
|
Wrona M, Nerín C. Analytical Approaches for Analysis of Safety of Modern Food Packaging: A Review. Molecules 2020; 25:E752. [PMID: 32050512 PMCID: PMC7037176 DOI: 10.3390/molecules25030752] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2019] [Revised: 01/31/2020] [Accepted: 02/06/2020] [Indexed: 12/23/2022] Open
Abstract
Nowadays, food packaging is a crucial tool for preserving food quality and has become an inseparable part of our daily life. Strong consumer demand and market trends enforce more advanced and creative forms of food packaging. New packaging development requires safety evaluations that always implicate the application of complex analytical methods. The present work reviews the development and application of new analytical methods for detection of possible food contaminants from the packaging origin on the quality and safety of fresh food. Among food contaminants migrants, set-off migrants from printing inks, polymer degradation products, and aromatic volatile compounds can be found that may compromise the safety and organoleptic properties of food. The list of possible chemical migrants is very wide and includes antioxidants, antimicrobials, intentionally added substances (IAS), non-intentionally added substances (NIAS), monomers, oligomers, and nanoparticles. All this information collected prior to the analysis will influence the type of analyzing samples and molecules (analytes) and therefore the selection of a convenient analytical method. Different analytical strategies will be discussed, including techniques for direct polymer analysis.
Collapse
Affiliation(s)
| | - Cristina Nerín
- Department of Analytical Chemistry, Aragon Institute of Engineering Research I3A, University of Zaragoza, María de Luna, 3, 50018 Zaragoza, Spain;
| |
Collapse
|
18
|
Ruan X, Xing L, Peng J, Li S, Song Y, Sun Q. A simplified fabric phase sorptive extraction method for the determination of amphetamine drugs in water samples using liquid chromatography-mass spectrometry. RSC Adv 2020; 10:10854-10866. [PMID: 35492944 PMCID: PMC9050397 DOI: 10.1039/c9ra10138a] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2019] [Accepted: 02/03/2020] [Indexed: 12/04/2022] Open
Abstract
Fabric phase sorptive extraction (FPSE) can directly extract the target analytes and simultaneously determine many similar substances from complicated sample matrices. Also, it has very high chemical stability. Therefore, we used fabric phase sorptive extraction to analyze three amphetamine drugs (amphetamine (AM), methamphetamine (MAM), and 3,4-methylenedioxymethamphetamine (MDMA)) in water. This was coupled with ultrahigh-performance liquid chromatography and tandem mass spectrometry. The effects of different sorbent chemistries such as sorption time, ratios of back-extraction solvents, back-extraction time, and the salt effect on the extraction efficiency were studied; the optimum operation conditions were determined. Medium polarity polar polymer-coated FPSE media were created using short-chain poly (tetrahydrofuran) (PTHF). This is the most efficient extraction media for the analytes of interest. Under the optimized conditions, the linear range of the three amphetamine drugs were 0.1–150.0 (AM, MAM) and 0.5–200 ng mL−1 (MDMA). The correlation coefficients (γ) were 0.9947 (AM), 0.9925 (MAM), and 0.9918 (MDMA). The detection limits (LOD) were 0.025 ng mL−1 for AM, 0.029 ng mL−1 for MAM, and 0.01 ng mL−1 for MDMA. The corresponding limit of quantification values (LOQ) were 0.083 ng mL−1, 0.097 ng mL−1, and 0.031 ng mL−1, respectively. The recoveries were 73.4–91.6%, 82.6–95.4%, and 92.7–95.3%, respectively, and the relative standard deviations (RSD) were 1.65–6.88%, 1.38–6.11%, and 1.58–7.34%, respectively. Moreover, our method can be successfully applied for the analysis of amphetamines in wastewater samples, and at the same time, lays the foundation for the future detection of such substances. Fabric phase sorptive extraction (FPSE) can directly extract the target analytes and simultaneously determine many similar substances from complicated sample matrices.![]()
Collapse
Affiliation(s)
- Xiaomeng Ruan
- Criminal Investigation Police University of China
- China
| | - Limei Xing
- Criminal Investigation Police University of China
- China
| | - Ju Peng
- Criminal Investigation Police University of China
- China
| | - Shiying Li
- Criminal Investigation Police University of China
- China
| | - Yiqun Song
- Criminal Investigation Police University of China
- China
| | - Qianqian Sun
- Criminal Investigation Police University of China
- China
| |
Collapse
|
19
|
Celeiro M, Acerbi R, Kabir A, Furton KG, Llompart M. Development of an analytical methodology based on fabric phase sorptive extraction followed by gas chromatography-tandem mass spectrometry to determine UV filters in environmental and recreational waters. Anal Chim Acta X 2019; 4:100038. [PMID: 33117984 PMCID: PMC7587048 DOI: 10.1016/j.acax.2019.100038] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2019] [Revised: 12/11/2019] [Accepted: 12/15/2019] [Indexed: 10/31/2022] Open
Abstract
A novel method based on fabric phase sorptive extraction (FPSE) followed by gas chromatography-tandem mass spectrometry (GC-MS/MS) has been validated for the simultaneous determination of 11 UV filters (ethylhexyl salicylate, benzyl salicylate, homosalate, benzophenone-3, isoamylmethoxycinnamate, 4-methylbenzylidenecamphor, methyl anthranilate, etocrylene, 2-ethylhexylmethoxycinnamate, 2-ethylhexyl p-dimethylaminobenzoate, and octocrylene), in natural and recreational waters. Major experimental parameters affecting FPSE procedure have been optimized to obtain the highest extraction efficiency. Different types and sizes of sol-gel coated FPSE media, sample volume, extraction time, and type and volume of desorption solvent were evaluated. The optimal conditions involved the use of a (2.0 × 2.5) cm2 FPSE device with PDMS based coating for the extraction of 20 mL of water for 20 min. The quantitative desorption of the target compounds was performed with 0.5-1 mL of ethyl acetate. The method was satisfactorily validated in terms of linearity, precision, repeatability and reproducibility. Recovery studies were performed at different concentration levels in real water matrices to show its suitability, obtaining mean values about 90% and satisfactory precision. LODs were at the low ng L-1 in all cases. Finally, the validated FPSE-GC-MS/MS method was applied to different real samples, including environmental water (lake, river, seawater) and recreational water (swimming-pool), where 8 out of the 11 studied compounds were detected at concentrations between 0.12-123 μg L-1. FPSE is proposed as an efficient and simple alternative to other extraction and microextraction techniques for the analysis of UV filters in waters. Since no matrix effects were observed, quantification could be carried out by conventional calibration with standard solutions, without the need to perform the complete FPSE procedure, thus allowing a higher throughput in comparison with other microextraction techniques.
Collapse
Affiliation(s)
- Maria Celeiro
- CRETUS Institute, Department of Analytical Chemistry, Nutrition and Food Science, Faculty of Chemistry, Universidade de Santiago de Compostela, E-15782, Santiago de Compostela, Spain
| | - Ruben Acerbi
- CRETUS Institute, Department of Analytical Chemistry, Nutrition and Food Science, Faculty of Chemistry, Universidade de Santiago de Compostela, E-15782, Santiago de Compostela, Spain
| | - Abuzar Kabir
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL-33199, USA
| | - Kenneth G Furton
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL-33199, USA
| | - Maria Llompart
- CRETUS Institute, Department of Analytical Chemistry, Nutrition and Food Science, Faculty of Chemistry, Universidade de Santiago de Compostela, E-15782, Santiago de Compostela, Spain
| |
Collapse
|
20
|
Lastovka AV, Rogachev AD, Il'ina IV, Kabir A, Volcho KP, Fadeeva VP, Pokrovsky AG, Furton KG, Salakhutdinov NF. Comparison of dried matrix spots and fabric phase sorptive extraction methods for quantification of highly potent analgesic activity agent (2R,4aR,7R,8aR)-4,7-dimethyl-2-(thiophen-2-yl)octahydro-2H-chromen-4-ol in rat whole blood and plasma using LC-MS/MS. J Chromatogr B Analyt Technol Biomed Life Sci 2019; 1132:121813. [PMID: 31706184 DOI: 10.1016/j.jchromb.2019.121813] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2019] [Revised: 09/20/2019] [Accepted: 09/21/2019] [Indexed: 12/29/2022]
Abstract
The methods for quantification of highly potent analgesic agent (2R,4aR,7R,8aR)-4,7-dimethyl-2-(thiophen-2-yl)octahydro-2H-chromen-4-ol in rat whole blood and plasma were developed and validated using dried matrix spots (DMS) or fabric phase sorptive extraction (FPSE) techniques in combination with LC-MS/MS. 2-Adamantylamine hydrochloride was used as an internal standard (IS). Chromatographic separation was carried out on a reversed-phase column (2.0×75 mm, 5 μm) using water containing 0.1% formic acid and methanol containing 0.1% formic acid as mobile phases in gradient mode at a flow rate of 200 μL/min. The mass spectrometric detection was performed using electrospray ionization (ESI) in positive ion mode. MRM transitions were m/z 284.5 → 137.2/157.4 for the analgesic agent and m/z 152.3 → 93.1/107.2 for IS. Calibration curves were linear within 20-5000 ng/mL in dried plasma spots (DPS) or dried blood spots (DBS) experiments. The linearity was obtained in the range of 20-5000 ng/mL and 50-5000 ng/mL for plasma-FPSE and blood-FPSE experiments, respectively. The intra- and inter-day accuracy and precision did not exceed acceptable limits. The mean extraction recovery (%) was 26 for DPS, 25 for DBS, 38 for plasma-FPSE, 31 for blood-FPSE.
Collapse
Affiliation(s)
- Anastasiya V Lastovka
- N. N. Vorozhtsov Novosibirsk Institute of Organic Chemistry of the Siberian Branch of Russian Academy of Sciences, Lavrent'ev ave., 9, 630090 Novosibirsk, Russia; Novosibirsk State University, Pirogov St., 2, 630090 Novosibirsk, Russia.
| | - Artem D Rogachev
- N. N. Vorozhtsov Novosibirsk Institute of Organic Chemistry of the Siberian Branch of Russian Academy of Sciences, Lavrent'ev ave., 9, 630090 Novosibirsk, Russia; Novosibirsk State University, Pirogov St., 2, 630090 Novosibirsk, Russia
| | - Irina V Il'ina
- N. N. Vorozhtsov Novosibirsk Institute of Organic Chemistry of the Siberian Branch of Russian Academy of Sciences, Lavrent'ev ave., 9, 630090 Novosibirsk, Russia
| | - Abuzar Kabir
- Department of Chemistry and Biochemistry, International Forensic Research Institute, Florida International University, 11200 SW 8th St., Miami, FL 33199, USA.
| | - Konstantin P Volcho
- N. N. Vorozhtsov Novosibirsk Institute of Organic Chemistry of the Siberian Branch of Russian Academy of Sciences, Lavrent'ev ave., 9, 630090 Novosibirsk, Russia; Novosibirsk State University, Pirogov St., 2, 630090 Novosibirsk, Russia
| | - Valentina P Fadeeva
- N. N. Vorozhtsov Novosibirsk Institute of Organic Chemistry of the Siberian Branch of Russian Academy of Sciences, Lavrent'ev ave., 9, 630090 Novosibirsk, Russia; Novosibirsk State University, Pirogov St., 2, 630090 Novosibirsk, Russia
| | - Andrey G Pokrovsky
- Novosibirsk State University, Pirogov St., 2, 630090 Novosibirsk, Russia
| | - Kenneth G Furton
- Department of Chemistry and Biochemistry, International Forensic Research Institute, Florida International University, 11200 SW 8th St., Miami, FL 33199, USA
| | - Nariman F Salakhutdinov
- N. N. Vorozhtsov Novosibirsk Institute of Organic Chemistry of the Siberian Branch of Russian Academy of Sciences, Lavrent'ev ave., 9, 630090 Novosibirsk, Russia; Novosibirsk State University, Pirogov St., 2, 630090 Novosibirsk, Russia
| |
Collapse
|
21
|
Locatelli M, Tartaglia A, Piccolantonio S, Di Iorio LA, Sperandio E, Ulusoy HI, Furton KG, Kabir A. Innovative Configurations of Sample Preparation Techniques Applied in Bioanalytical Chemistry: A Review. CURR ANAL CHEM 2019. [DOI: 10.2174/1573411015666190301145042] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Background:
Recently, in all fields of analytical chemistry, increased attention has been
paid to extraction procedures and instrumental methods, which are easily scalable and are able to automate
in order to improve the “high-throughput” capability.
Introduction:
The main goal of these applications relates to an improvement of the precision in the
quantitative analysis, reduction of different sources of errors, decrease the analysis time and, in general,
improve the analytical performances. Often these points can be in contrast to each other, not allowing
to achieve the expected result but forcing a compromise between the objectives of the method
and the analytical performance.
Methods:
In this review, following the evolution of the (micro)extraction procedures and instrument
configurations, the recent procedures used in bioanalytical chemistry are critically evaluated. The
aim of this paper is providing an overview of the approaches available in order to perform on-line
coupling of various extraction techniques with chromatographic methods for the analysis of different
compounds in various samples. Furthermore, a comparison between off-line and on-line systems, advantages
of on-line systems applied on major extractive techniques and future perspectives are described.
Result:
The extraction methods suitable for on-line coupling covered in this review are: liquid-liquid
extraction (LLE), solid phase extraction (SPE), solid phase microextraction (SPME), dispersive liquid-
liquid microextraction (DLLME), microextraction by packed sorbent (MEPS), supercritical fluid
extraction (SFE) and fabric phase sorptive extraction (FPSE).
Conclusion:
An overview of the micro-extraction techniques mentioned above was provided, making
a comparison between them and focusing attention on future perspectives.
Collapse
Affiliation(s)
- Marcello Locatelli
- Department of Pharmacy, University “G. d’Annunzio” of Chieti-Pescara, Chieti (CH), Italy
| | - Angela Tartaglia
- Department of Pharmacy, University “G. d’Annunzio” of Chieti-Pescara, Chieti (CH), Italy
| | - Silvia Piccolantonio
- Department of Pharmacy, University “G. d’Annunzio” of Chieti-Pescara, Chieti (CH), Italy
| | | | - Elena Sperandio
- Department of Pharmacy, University “G. d’Annunzio” of Chieti-Pescara, Chieti (CH), Italy
| | - Halil Ibrahim Ulusoy
- Faculty of Pharmacy, Department of Analytical Chemistry, Cumhuriyet University, Sivas, Turkey
| | - Kenneth G. Furton
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL, United States
| | - Abuzar Kabir
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL, United States
| |
Collapse
|
22
|
Alampanos V, Kabir A, Furton KG, Samanidou V, Papadoyannis I. Fabric phase sorptive extraction for simultaneous observation of four penicillin antibiotics from human blood serum prior to high performance liquid chromatography and photo-diode array detection. Microchem J 2019. [DOI: 10.1016/j.microc.2019.103964] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
23
|
Taraboletti A, Goudarzi M, Kabir A, Moon BH, Laiakis EC, Lacombe J, Ake P, Shoishiro S, Brenner D, Fornace AJ, Zenhausern F. Fabric Phase Sorptive Extraction-A Metabolomic Preprocessing Approach for Ionizing Radiation Exposure Assessment. J Proteome Res 2019; 18:3020-3031. [PMID: 31090424 PMCID: PMC7437658 DOI: 10.1021/acs.jproteome.9b00142] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
The modern application of mass spectrometry-based metabolomics to the field of radiation assessment and biodosimetry has allowed for the development of prompt biomarker screenings for radiation exposure. Our previous work on radiation assessment, in easily accessible biofluids (such as urine, blood, saliva), has revealed unique metabolic perturbations in response to radiation quality, dose, and dose rate. Nevertheless, the employment of swift injury assessment in the case of a radiological disaster still remains a challenge as current sample processing can be time consuming and cause sample degradation. To address these concerns, we report a metabolomics workflow using a mass spectrometry-compatible fabric phase sorptive extraction (FPSE) technique. FPSE employs a matrix coated with sol-gel poly(caprolactone-b-dimethylsiloxane-b-caprolactone) that binds both polar and nonpolar metabolites in whole blood, eliminating serum processing steps. We confirm that the FPSE preparation technique combined with liquid chromatography-mass spectrometry can distinguish radiation exposure markers such as taurine, carnitine, arachidonic acid, α-linolenic acid, and oleic acid found 24 h after 8 Gy irradiation. We also note the effect of different membrane fibers on both metabolite extraction efficiency and the temporal stabilization of metabolites in whole blood at room temperature. These findings suggest that the FPSE approach could work in future technology to triage irradiated individuals accurately, via biomarker screening, by providing a novel method to stabilize biofluids between collection and sample analysis.
Collapse
Affiliation(s)
- Alexandra Taraboletti
- Department of Oncology, Georgetown University Medical Center, Georgetown University, 3800 Reservoir Road Northwest, Washington, District of Columbia 20057, United States
| | - Maryam Goudarzi
- Department of Biochemistry and Molecular & Cellular Biology, Georgetown University Medical Center, Georgetown University, 3800 Reservoir Road Northwest, Washington, District of Columbia 20057, United States
- Lerner Research Institute, Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, Ohio 44195, United States
| | - Abuzar Kabir
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, 11200 Southwest Eighth Street, Miami, Florida 33199, United States
| | - Bo-Hyun Moon
- Department of Oncology, Georgetown University Medical Center, Georgetown University, 3800 Reservoir Road Northwest, Washington, District of Columbia 20057, United States
| | - Evagelia C. Laiakis
- Department of Oncology, Georgetown University Medical Center, Georgetown University, 3800 Reservoir Road Northwest, Washington, District of Columbia 20057, United States
- Department of Biochemistry and Molecular & Cellular Biology, Georgetown University Medical Center, Georgetown University, 3800 Reservoir Road Northwest, Washington, District of Columbia 20057, United States
| | - Jerome Lacombe
- Center for Applied NanoBiosience and Medicine, University of Arizona, 475 North Fifth Street, Phoenix, Arizona 85004, United States
| | - Pelagie Ake
- Department of Oncology, Georgetown University Medical Center, Georgetown University, 3800 Reservoir Road Northwest, Washington, District of Columbia 20057, United States
| | - Sueoka Shoishiro
- Center for Applied NanoBiosience and Medicine, University of Arizona, 475 North Fifth Street, Phoenix, Arizona 85004, United States
| | - David Brenner
- Center for Radiological Research, Columbia University, 630 West 168th Street, New York, New York 10032, United States
| | - Albert J. Fornace
- Department of Oncology, Georgetown University Medical Center, Georgetown University, 3800 Reservoir Road Northwest, Washington, District of Columbia 20057, United States
- Department of Biochemistry and Molecular & Cellular Biology, Georgetown University Medical Center, Georgetown University, 3800 Reservoir Road Northwest, Washington, District of Columbia 20057, United States
| | - Frederic Zenhausern
- Center for Applied NanoBiosience and Medicine, University of Arizona, 475 North Fifth Street, Phoenix, Arizona 85004, United States
- Translational Genomics Research Institute, 445 North Fifth Street, Phoenix, Arizona 85004, United States
- Department of Basic Medical Sciences, College of Medicine Phoenix, 425 North Fifth Street, Phoenix, Arizona 85004, United States
| |
Collapse
|
24
|
Kaur R, Kaur R, Grover A, Rani S, Malik AK, Kabir A, Furton KG. Fabric phase sorptive extraction/GC-MS method for rapid determination of broad polarity spectrum multi-class emerging pollutants in various aqueous samples. J Sep Sci 2019; 42:2407-2417. [PMID: 31074186 DOI: 10.1002/jssc.201900089] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2019] [Revised: 04/20/2019] [Accepted: 05/03/2019] [Indexed: 12/15/2022]
Abstract
A rapid extraction and cleanup method using selective fabric phase sorptive extraction combined with gas chromatography and mass spectrometry has been developed and validated for the determination of broad polarity spectrum emerging pollutants, ethyl paraben, butyl paraben, diethyl phthalate, dibutyl phthalate, lidocaine, prilocaine, triclosan, and bisphenol A in various aqueous samples. Some important parameters of fabric phase sorptive extraction such as extraction time, matrix pH, stirring speed, type and volume of desorption solvent were investigated and optimized. Calibration curves were obtained in the concentration range 0.05-500 ng/mL. Under the optimum conditions, the limits of detection were in the range 0.009 -0.021 ng/mL. This method was validated by analyzing the compounds in spiked aqueous samples at different levels with recoveries of 93 to 99% and relative standard deviations of <6%. The developed method was applied for the determination of the emerging contaminants in tap water, municipal water, ground water, sewage water, and sludge water samples. The results demonstrate that fabric phase sorptive extraction has great potential in the preconcentration of trace analytes in complex matrix.
Collapse
Affiliation(s)
- Ramandeep Kaur
- Department of Chemistry, Punjabi University, Patiala, India
| | - Ripneel Kaur
- Department of Chemistry, Punjabi University, Patiala, India
| | - Aman Grover
- Department of Chemistry, Punjabi University, Patiala, India
| | - Susheela Rani
- Department of Chemistry, Punjabi University, Patiala, India
| | | | - Abuzar Kabir
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL, USA
| | - Kenneth G Furton
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL, USA
| |
Collapse
|
25
|
Otoukesh M, Nerín C, Aznar M, Kabir A, Furton KG, Es'haghi Z. Determination of adhesive acrylates in recycled polyethylene terephthalate by fabric phase sorptive extraction coupled to ultra performance liquid chromatography - mass spectrometry. J Chromatogr A 2019; 1602:56-63. [PMID: 31155144 DOI: 10.1016/j.chroma.2019.05.044] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2019] [Revised: 05/22/2019] [Accepted: 05/23/2019] [Indexed: 12/24/2022]
Abstract
This article presents fabric phase sorptive extraction (FPSE) as a simple and effective pre-concentration method for the enrichment of acrylate compounds in different food simulants and subsequent analysis of the extracts by ultra-high-performance liquid chromatography with mass spectrometric detection (UPLC-MS). Acrylate compounds come from acrylic adhesives used commonly for sticking the paper labels on polyethylene terephthalate (PET) bottles and therefore, they may exist in recycled polyethylene terephthalate (rPET). Four acrylates were studied: ethylene glycol dimethacrylate (EGDM), pentaerythritol triacrylate (PETA), triethylene glycol diacrylate (TEGDA) and trimethylolpropane triacrylate (TMPTA). Five different types of FPSE media coated with different sol-gel sorbents were studied and finally sol-gel polyethylene glycol- polypropylene glycol-polyethylene glycol triblock copolymer (PEG-PPG-PEG) coated FPSE media was chosen for its satisfactory results. The optimal conditions affecting the extraction efficiency of compounds were determined in three different food simulants. Statistical evaluation of this method reveals good linearity and precision. Under the optimized conditions, the method provided limits of detection of the compounds in the range of (0.1-1.9 ng g-1, 0.1-1.2 ng g-1, 0.2-2.3 ng g-1) in EtOH 10%, HAc 3% and EtOH 20% and the enrichment factor values (EFs) after applying N2 were in the range of 11.1-25.0, 13.8-26.3, 8.3-21.9, in simulants A, B and C respectively. The optimized method was applied successfully to analyze thirteen types of recycled PET samples. Acrylates were found in some of the samples at ng g-1 levels.
Collapse
Affiliation(s)
- Mahdiyeh Otoukesh
- Analytical Chemistry Department, GUIA Group, I3A, EINA, University of Zaragoza, Made Luna 3, 50018, Zaragoza, Spain; Department of Chemistry, Faculty of Sciences, Ferdowsi University of Mashhad, Iran
| | - Cristina Nerín
- Analytical Chemistry Department, GUIA Group, I3A, EINA, University of Zaragoza, Made Luna 3, 50018, Zaragoza, Spain.
| | - Margarita Aznar
- Analytical Chemistry Department, GUIA Group, I3A, EINA, University of Zaragoza, Made Luna 3, 50018, Zaragoza, Spain
| | - Abuzar Kabir
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, 11200 SW 8th Street, Miami, FL, 33199, USA
| | - Kenneth G Furton
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, 11200 SW 8th Street, Miami, FL, 33199, USA
| | - Zarrin Es'haghi
- Department of Chemistry, Payame Noor University, 19395-4697 Tehran, Iran
| |
Collapse
|
26
|
Comparison between Exhaustive and Equilibrium Extraction Using Different SPE Sorbents and Sol-Gel Carbowax 20M Coated FPSE Media. Molecules 2019; 24:molecules24030382. [PMID: 30678177 PMCID: PMC6385024 DOI: 10.3390/molecules24030382] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2018] [Revised: 01/18/2019] [Accepted: 01/20/2019] [Indexed: 01/15/2023] Open
Abstract
This paper reports the performance comparison between the exhaustive and equilibrium extraction using classical Avantor C18 solid phase extraction (SPE) sorbent, hydrophilic-lipophilic balance (HLB) SPE sorbent, Sep-Pak C18 SPE sorbent, novel sol-gel Carbowax 20M (sol-gel CW 20M) SPE sorbent, and sol-gel CW 20M coated fabric phase sorptive extraction (FPSE) media for the simultaneous extraction and analysis of three inflammatory bowel disease (IBD) drugs that possess logP values (polarity) ranging from 1.66 for cortisone, 2.30 for ciprofloxacin, and 2.92 for sulfasalazine. Both the commercial SPE phases and in-house synthesized sol-gel CW 20M SPE phases were loaded in SPE cartridges and the extractions were carried out under an exhaustive extraction mode. FPSE was carried out under an equilibrium extraction mode. The drug compounds were resolved using a Luna C18 column (250 mm × 4.6 mm; 5 m particle size) in gradient elution mode within 20 min and the method was validated in compliance with international guidelines for the bioanalytical method validation. Novel in-house synthesized and loaded sol-gel CW 20M SPE sorbent cartridges were characterized in terms of their extraction capability, breakthrough volume, retention volume, hold-up volume, number of the theoretical plate, and the retention factor.
Collapse
|
27
|
Mesa R, Kabir A, Samanidou V, Furton KG. Simultaneous determination of selected estrogenic endocrine disrupting chemicals and bisphenol A residues in whole milk using fabric phase sorptive extraction coupled to HPLC-UV detection and LC-MS/MS. J Sep Sci 2018; 42:598-608. [DOI: 10.1002/jssc.201800901] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2018] [Revised: 10/31/2018] [Accepted: 11/04/2018] [Indexed: 11/10/2022]
Affiliation(s)
- Rodolfo Mesa
- Department of Chemistry and Biochemistry; International Forensic Research Institute; Florida International University; Miami USA
| | - Abuzar Kabir
- Department of Chemistry and Biochemistry; International Forensic Research Institute; Florida International University; Miami USA
| | - Victoria Samanidou
- Department of Chemistry; Laboratory of Analytical Chemistry; Aristotle University of Thessaloniki; Greece
| | - Kenneth G. Furton
- Department of Chemistry and Biochemistry; International Forensic Research Institute; Florida International University; Miami USA
| |
Collapse
|
28
|
Pérez-Mayán L, Rodríguez I, Ramil M, Kabir A, Furton KG, Cela R. Fabric phase sorptive extraction followed by ultra-performance liquid chromatography-tandem mass spectrometry for the determination of fungicides and insecticides in wine. J Chromatogr A 2018; 1584:13-23. [PMID: 30502037 DOI: 10.1016/j.chroma.2018.11.025] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2018] [Revised: 11/02/2018] [Accepted: 11/15/2018] [Indexed: 12/31/2022]
Abstract
In this work, fabric phase sorptive extraction (FPSE) is investigated for the extraction and preconcentration of ultra-trace level residues of fungicides (19 compounds) and insecticides (3 species) in wine samples. Subsequently, the preconcentrated analytes are selectively determined using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Parameters affecting the efficiency and repeatability of the extraction are evaluated in depth; moreover, the proposed method is characterized in terms of linear response range, trueness, precision and limits of quantification (LOQs). The set-up of the extraction process and the type of coating were the variables exerting the most prominent effects in the repeatability and the yield of the extraction, respectively. Under optimized conditions, samples (10 mL of wine diluted with the same volume of ultrapure water) were extracted with a small amount of cellulose fabric (3 discs with 4 mm of diameter: total surface 0.38 cm2) coated with a sol-gel polyethylene glycol sorbent (sorbent amount 3.3 mg), immersed in the diluted sample, without being in direct contact with the PTFE covered magnetic stir bar. Following the overnight extraction step, analytes were quantitatively recovered using only 0.3 mL of an ACN-MeOH (80:20) mixture. Under equilibrium sampling conditions, the linear response range of the method varied from 0.2 to 200 ng mL-1, with limits of quantification (LOQs) between 0.03 and 0.3 ng mL-1. Relative recoveries ranged from 77 ± 6% to 118 ± 4%, and from 87 ± 4% to 121 ± 6% for red and white wines, respectively. Application of the optimized method to commercial wines demonstrated the existence of up to 9 out of 22 investigated compounds in the same wine sample. The compound identified at the highest concentration was iprovalicarb (IPR), with a value of 130 ± 9 ng mL-1 in a commercial white wine.
Collapse
Affiliation(s)
- L Pérez-Mayán
- Department of Analytical Chemistry, Nutrition and Food Sciences, IIAA-Institute for Food Analysis and Research, Universidade de Santiago de Compostela, R/Constantino Candeira SN, 15782, Santiago de Compostela, Spain
| | - I Rodríguez
- Department of Analytical Chemistry, Nutrition and Food Sciences, IIAA-Institute for Food Analysis and Research, Universidade de Santiago de Compostela, R/Constantino Candeira SN, 15782, Santiago de Compostela, Spain
| | - M Ramil
- Department of Analytical Chemistry, Nutrition and Food Sciences, IIAA-Institute for Food Analysis and Research, Universidade de Santiago de Compostela, R/Constantino Candeira SN, 15782, Santiago de Compostela, Spain.
| | - A Kabir
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, 11200 SW 8thStreet, Miami, FL, 33199, USA.
| | - K G Furton
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, 11200 SW 8thStreet, Miami, FL, 33199, USA
| | - R Cela
- Department of Analytical Chemistry, Nutrition and Food Sciences, IIAA-Institute for Food Analysis and Research, Universidade de Santiago de Compostela, R/Constantino Candeira SN, 15782, Santiago de Compostela, Spain
| |
Collapse
|
29
|
Sun T, Wang D, Tang Y, Xing X, Zhuang J, Cheng J, Du Z. Fabric-phase sorptive extraction coupled with ion mobility spectrometry for on-site rapid detection of PAHs in aquatic environment. Talanta 2018; 195:109-116. [PMID: 30625520 DOI: 10.1016/j.talanta.2018.11.018] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2018] [Revised: 11/01/2018] [Accepted: 11/05/2018] [Indexed: 01/03/2023]
Abstract
The contamination of water is a high risk to human health, so there is an urgent need to rapidly detect water pollution in the field. Ion mobility spectrometry (IMS) is suitable for on-site analysis with the merit of rapid analysis and compact size. In this study, we developed a new method which coupled fabric phase sorptive extraction (FPSE) with IMS for rapid detection of polycyclic aromatic hydrocarbons (PAHs) in water present in the field. Polydimethylsiloxane (PDMS) was coated on the glass fiber cloth through a sol-gel reaction. After extracting the PAHs in water, the fabric coated PDMS could be directly put into the inlet of IMS instrument for thermal desorption. The PAHs were analyzed by the IMS instrument operated in the positive ion mode with a corona discharge (CD) ionization source. The primary parameters affecting extraction efficiency such as extraction time, extraction temperature, and ionic strength were investigated and optimized by using phenanthrene (Phe), benzo[a]anthracene (BaA) and benzo[a]pyrene (BaP) as model compounds. Under the optimal conditions, the FPSE-IMS detection limits were 5 ng ml-1,8 ng ml-1 and 10 ng ml-1 respectively. Satisfactory recoveries were obtained in the range from 80.5% to 100.5% by testing the spiked real water samples and validated by the standard method(HJ487-2009). Based on the results, the method of FPSE-IMS could be feasibly applied for monitoring the water quality on-site and providing early warning in the field.
Collapse
Affiliation(s)
- Tangqiang Sun
- College of Science, Beijing Key Laboratory of Environmentally Harmful Chemical Analysis, Beijing University of Chemical Technology, Beijing, China
| | - Di Wang
- College of Science, Beijing Key Laboratory of Environmentally Harmful Chemical Analysis, Beijing University of Chemical Technology, Beijing, China
| | - Yan Tang
- College of Science, Beijing Key Laboratory of Environmentally Harmful Chemical Analysis, Beijing University of Chemical Technology, Beijing, China
| | - Xuebin Xing
- College of Science, Beijing Key Laboratory of Environmentally Harmful Chemical Analysis, Beijing University of Chemical Technology, Beijing, China
| | - Jingcong Zhuang
- College of Science, Beijing Key Laboratory of Environmentally Harmful Chemical Analysis, Beijing University of Chemical Technology, Beijing, China
| | - Jiaxing Cheng
- College of Science, Beijing Key Laboratory of Environmentally Harmful Chemical Analysis, Beijing University of Chemical Technology, Beijing, China
| | - Zhenxia Du
- College of Science, Beijing Key Laboratory of Environmentally Harmful Chemical Analysis, Beijing University of Chemical Technology, Beijing, China.
| |
Collapse
|
30
|
Szczepańska N, Kudłak B, Namieśnik J. Recent advances in assessing xenobiotics migrating from packaging material – A review. Anal Chim Acta 2018; 1023:1-21. [DOI: 10.1016/j.aca.2018.03.045] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2017] [Revised: 03/17/2018] [Accepted: 03/21/2018] [Indexed: 12/30/2022]
|
31
|
Abstract
Fabric phase sorptive extraction (FPSE) is a novel and green sample preparation technique introduced in 2014. FPSE utilizes a natural or synthetic permeable and flexible fabric substrate chemically coated with a sol-gel organic-inorganic hybrid sorbent in the form of ultra-thin coating, which leads to a fast and sensitive micro-extraction device. The flexible FPSE requires no modification of samples and allows direct extraction of analytes. Sol-gel sorbent-coated FPSE media possesses high chemical, solvent, and thermal stability due to the strong covalent bonding between the substrate and the sol-gel sorbent. Therefore, any elution solvent can be used in a small volume, which achieves a high pre-concentration factor without requiring any solvent evaporation and sample reconstitution step. Taking into consideration the complexity of the samples and the need of further minimization and automation, some new, alternative modes of the FPSE have also been developed. Therefore, FPSE has attracted the interest of the scientific community that deals with sample pre-treatment and has been successfully applied for the extraction and determination of many analytes in environmental samples as well as in food and biological samples. The objective of the current review is to present and classify the applications of FPSE according to different sample categories and to briefly show the progress, advantages, and the main principles of the proposed technique.
Collapse
|
32
|
Mass Spectrometric Analysis of Bisphenol A Desorption from Titania Nanoparticles: Ammonium Acetate, Fluoride, Formate, and Hydroxide as Chemical Desorption Agents. Methods Protoc 2018; 1:mps1030026. [PMID: 31164568 PMCID: PMC6481066 DOI: 10.3390/mps1030026] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2018] [Revised: 07/12/2018] [Accepted: 07/13/2018] [Indexed: 02/06/2023] Open
Abstract
Bisphenol A (BPA) is a widely used chemical in several consumer products and a well-studied environmental toxicant, and therefore, its accurate measurement is highly demanded. However, the co-presence of nanoparticles as an emerging class of contaminants could result in inaccurate determination of BPA due to binding of BPA onto nanoparticle surface. In this study, mass spectrometry (MS) was used to investigate desorption of BPA bound on the surface of titania (TiO2) nanoparticles in water. Ammonium acetate, fluoride, formate, and hydroxide were evaluated as chemical agents for their desorption capabilities. The percentages of recovery, adsorption, and desorption were determined by this new method without requiring any prior separation of nanoparticles from BPA. MS analysis demonstrated the desorption of BPA by 10–20 mM of ammonium hydroxide for a mixture of 5 µg/mL BPA and 10 µg/mL TiO2 nanoparticles, with a desorption efficiency of 72 ± 1%. Due to adsorption of BPA onto the nanoparticle surface that was inefficient for electrospray ionization, the resulting abundance of target ions could be reduced in the detection of BPA by mass spectrometry. As such, these findings collectively promise an accurate determination of the total BPA concentration in water whether it exists in the free or bound form. Efficient desorption of contaminants from the surface of nanoparticles would improve the accuracy of the contaminant analysis by mass spectrometry.
Collapse
|
33
|
Kabir A, Furton KG, Tinari N, Grossi L, Innosa D, Macerola D, Tartaglia A, Di Donato V, D'Ovidio C, Locatelli M. Fabric phase sorptive extraction-high performance liquid chromatography-photo diode array detection method for simultaneous monitoring of three inflammatory bowel disease treatment drugs in whole blood, plasma and urine. J Chromatogr B Analyt Technol Biomed Life Sci 2018; 1084:53-63. [DOI: 10.1016/j.jchromb.2018.03.028] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2018] [Revised: 03/13/2018] [Accepted: 03/15/2018] [Indexed: 10/17/2022]
|
34
|
Recent Trends in Microextraction Techniques Employed in Analytical and Bioanalytical Sample Preparation. SEPARATIONS 2017. [DOI: 10.3390/separations4040036] [Citation(s) in RCA: 97] [Impact Index Per Article: 13.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|
35
|
Abstract
The theory and working principle of fabric phase sorptive extraction (FPSE) is presented. FPSE innovatively integrates the benefits of sol–gel coating technology and the rich surface chemistry of cellulose/polyester/fiberglass fabrics, resulting in a microextraction device with very high sorbent loading in the form of an ultra-thin coating. This porous sorbent coating and the permeable substrate synergistically facilitate fast extraction equilibrium. The flexibility of the FPSE device allows its direct insertion into original, unmodified samples of different origin. Strong chemical bonding between the sol–gel sorbent and the fabric substrate permits the exposure of FPSE devices to any organic solvent for analyte back-extraction/elution. As a representative sorbent, sol–gel poly(ethylene glycol) coating was generated on cellulose substrates. Five (cm2) segments of these coated fabrics were used as the FPSE devices for sample preparation using direct immersion mode. An important class of environmental pollutants—substituted phenols—was used as model compounds to evaluate the extraction performance of FPSE. The high primary contact surface area (PCSA) of the FPSE device and porous structure of the sol–gel coatings resulted in very high sample capacities and incredible extraction sensitivities in a relatively short period of time. Different extraction parameters were evaluated and optimized. The new extraction devices demonstrated part per trillion level detection limits for substitute phenols, a wide range of detection linearity, and good performance reproducibility.
Collapse
|
36
|
Samanidou V, Filippou O, Marinou E, Kabir A, Furton KG. Sol-gel-graphene-based fabric-phase sorptive extraction for cow and human breast milk sample cleanup for screening bisphenol A and residual dental restorative material before analysis by HPLC with diode array detection. J Sep Sci 2017; 40:2612-2619. [PMID: 28463409 DOI: 10.1002/jssc.201700256] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2017] [Revised: 04/07/2017] [Accepted: 04/14/2017] [Indexed: 11/11/2022]
Abstract
Fabric-phase sorptive extraction has already been recognized as a simple and green alternative to the conventional sorbent-based sorptive microextraction techniques, using hybrid organic-inorganic sorbent coatings chemically bonded to a flexible fabric surface. Herein, we have investigated the synergistic combination of the advanced material properties offered by sol-gel graphene sorbent and the simplicity of Fabric phase sorptive extraction approach in selectively extracting bisphenol A and residual monomers including bisphenol A glycerolatedimethacrylate, urethane dimethacrylate, and triethylene glycol dimethacrylate derived dental restorative materials from cow and human breast milk samples. Different coatings were evaluated. Final method development employed sol-gel graphene coated media. The main experimental parameters influencing extraction of the compounds, such as sorbent chemistry used, sample loading conditions, elution solvent, sorption stirring time, elution time, impact of protein precipitation, amount of sample, and matrix effect, were investigated and optimized. Absolute recovery values from standard solutions were 50% for bisphenol A, 78% for T triethylene glycol dimethacrylate, 110% for urethane dimethacrylate, and 103% for bisphenol A glycerolatedimethacrylate, while respective absolute recovery values from milk were 30, 52, 104, and 42%. Method validation was performed according to European Decision 657/2002/EC in terms of selectivity, sensitivity, linearity, accuracy, and precision.
Collapse
Affiliation(s)
- Victoria Samanidou
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, Greece
| | - Olga Filippou
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, Greece
| | - Eirini Marinou
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, Greece
| | - Abuzar Kabir
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL, USA
| | - Kenneth G Furton
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL, USA
| |
Collapse
|
37
|
Abstract
Since the introduction in 2014 of fabric phase sorptive extraction (FPSE) as a sample preparation technique, it has attracted the attention of many scientists working in the field of separation science. This novel sorbent extraction technique has successfully utilized the benefits of sol–gel derived hybrid sorbents and a plethora of fabric substrates, resulting in a highly efficient, sensitive and green sample pretreatment methodology. The proposed procedure is an easy and efficient pathway to extract target analytes from different matrices providing inherent advantages such as high sample loading capacity and short pretreatment time. The present review mainly focuses on the background and sol–gel chemistry for the preparation of new fabric sorbents as well as on the applications of FPSE for extracting target analytes, from the time that it was first introduced. New modes of FPSE including stir FPSE, stir-bar FPSE, dynamic FPSE, and automated on-line FPSE are also highlighted and commented upon in detail. FPSE has been effectively applied for the determination of various organic and inorganic analytes in different types of environmental and biological samples in high throughput analytical, environmental, and toxicological laboratories.
Collapse
|
38
|
Aznar M, Úbeda S, Nerin C, Kabir A, Furton KG. Fabric phase sorptive extraction as a reliable tool for rapid screening and detection of freshness markers in oranges. J Chromatogr A 2017; 1500:32-42. [PMID: 28433435 DOI: 10.1016/j.chroma.2017.04.006] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2016] [Revised: 04/04/2017] [Accepted: 04/06/2017] [Indexed: 01/03/2023]
Abstract
A simple, fast and sensitive analyte extraction method based on fabric phase sorptive extraction (FPSE) followed by gas chromatography-mass spectrometry (GC-MS) and ultra-performance liquid chromatography-quadrupole time of flight mass spectrometry (UPLC-QTOF-MS) analysis was developed for the analysis of 12 volatile compounds that represent most of the principal chemical families possessing different polarities and volatilities. Five FPSE media coated with different sol-gel sorbent chemistries having different polarities and selectivities were studied: long chain poly(dimethylsiloxane) (PDMS), short chain poly(tetrahydrofuran) (PTHF), Carbowax 20M (CW20M), short chain poly(dimethyl siloxane) (SC PDMS) and polyethylene glycol-polypropylene glycol-polyethylene glycol triblock copolymer (PEG-PPG-PEG). CW20M coated FPSE media was found to be the most efficient extraction media for the analytes of interest in the intended study. The developed methodology was applied to the analysis of orange juice obtained from fresh oranges and oranges after storing at 5°C for two months in order to identify the best chemical markers, both volatiles and non-volatiles, attributed to the freshness of orange. For this purpose, aliquots of the same juice extracts were analysed by GC-MS as well as by UPLC-QTOF-MS. Monoterpenes and terpenoids, such as terpinene, citronellal or estragole were among the volatile compounds that endured the biggest decrease after the extended storage period. Three non-volatile compounds including one amide (subaphyllin) and two flavanoids (tangeretin and nobiletin) also showed a clear decrease in signal intensity (>70%) after orange stored for two months.
Collapse
Affiliation(s)
- M Aznar
- Analytical Chemistry Department, GUIA Group, I3A, EINA, University of Zaragoza, Mª de Luna 3, 50018, Zaragoza, Spain
| | - S Úbeda
- Analytical Chemistry Department, GUIA Group, I3A, EINA, University of Zaragoza, Mª de Luna 3, 50018, Zaragoza, Spain
| | - C Nerin
- Analytical Chemistry Department, GUIA Group, I3A, EINA, University of Zaragoza, Mª de Luna 3, 50018, Zaragoza, Spain.
| | - A Kabir
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, 11200 SW 8th Street, Miami, FL, 33199, USA.
| | - K G Furton
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, 11200 SW 8th Street, Miami, FL, 33199, USA
| |
Collapse
|
39
|
Locatelli M, Kabir A, Innosa D, Lopatriello T, Furton KG. A fabric phase sorptive extraction-High performance liquid chromatography-Photo diode array detection method for the determination of twelve azole antimicrobial drug residues in human plasma and urine. J Chromatogr B Analyt Technol Biomed Life Sci 2017; 1040:192-198. [DOI: 10.1016/j.jchromb.2016.10.045] [Citation(s) in RCA: 54] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2016] [Revised: 10/07/2016] [Accepted: 10/26/2016] [Indexed: 01/17/2023]
|