Xu T, Li H, Dou P, Luo Y, Pu S, Mu H, Zhang Z, Feng D, Hu X, Wang T, Tan G, Chen C, Li H, Shi X, Hu C, Xu G. Concentric Hybrid Nanoelectrospray Ionization-Atmospheric Pressure Chemical Ionization Source for High-Coverage Mass Spectrometry Analysis of Single-Cell Metabolomics. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2306659. [PMID: 38359005 DOI: 10.1002/advs.202306659] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 02/04/2024] [Indexed: 02/17/2024]
Abstract
High-coverage mass spectrometry analysis of single-cell metabolomics remains challenging due to the extremely low abundance and wide polarity of metabolites and ultra-small volume in single cells. Herein, a novel concentric hybrid ionization source, nanoelectrospray ionization-atmospheric pressure chemical ionization (nanoESI-APCI), is ingeniously designed to detect polar and nonpolar metabolites simultaneously in single cells. The source is constructed by inserting a pulled glass capillary coaxially into a glass tube that acts as a dielectric barrier layer. Benefitting from the integrated advantages of nanoESI and APCI, its limit of detection is improved by one order of magnitude to 10 pg mL-1. After the operational parameter optimization, 254 metabolites detected in nanoESI-APCI are tentatively identified from a single cell, and 82 more than those in nanoESI. The developed nanoESI-APCI is successively applied to study the metabolic heterogeneity of human hepatocellular carcinoma tissue microenvironment united with laser capture microdissection (LCM), the discrimination of cancer cell types and subtypes, the metabolic perturbations to glucose starvation in MCF7 cells and the metabolic regulation of cancer stem cells. These results demonstrated that the nanoESI-APCI not only opens a new avenue for high-coverage and high-sensitivity metabolomics analysis of single cell, but also facilitates spatially resolved metabolomics study coupled with LCM.
Collapse
Affiliation(s)
- Tianrun Xu
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), University of Chinese Academy of Sciences, Liaoning Province Key Laboratory of Metabolomics, Dalian, Liaoning, 116023, P. R. China
| | - Hang Li
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), University of Chinese Academy of Sciences, Liaoning Province Key Laboratory of Metabolomics, Dalian, Liaoning, 116023, P. R. China
| | - Peng Dou
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), University of Chinese Academy of Sciences, Liaoning Province Key Laboratory of Metabolomics, Dalian, Liaoning, 116023, P. R. China
| | - Yuanyuan Luo
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), University of Chinese Academy of Sciences, Liaoning Province Key Laboratory of Metabolomics, Dalian, Liaoning, 116023, P. R. China
| | - Siming Pu
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), University of Chinese Academy of Sciences, Liaoning Province Key Laboratory of Metabolomics, Dalian, Liaoning, 116023, P. R. China
| | - Hua Mu
- The First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning, 116023, P. R. China
| | - Zhihao Zhang
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), University of Chinese Academy of Science, Dalian Key Laboratory for Online Analytical Instrumentation, Dalian, Liaoning, 116023, P. R. China
| | - Disheng Feng
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), University of Chinese Academy of Sciences, Liaoning Province Key Laboratory of Metabolomics, Dalian, Liaoning, 116023, P. R. China
| | - Xuesen Hu
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), University of Chinese Academy of Sciences, Liaoning Province Key Laboratory of Metabolomics, Dalian, Liaoning, 116023, P. R. China
| | - Ting Wang
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), University of Chinese Academy of Sciences, Liaoning Province Key Laboratory of Metabolomics, Dalian, Liaoning, 116023, P. R. China
| | - Guang Tan
- The First Affiliated Hospital of Dalian Medical University, Dalian, Liaoning, 116023, P. R. China
| | - Chuang Chen
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), University of Chinese Academy of Science, Dalian Key Laboratory for Online Analytical Instrumentation, Dalian, Liaoning, 116023, P. R. China
| | - Haiyang Li
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), University of Chinese Academy of Science, Dalian Key Laboratory for Online Analytical Instrumentation, Dalian, Liaoning, 116023, P. R. China
| | - Xianzhe Shi
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), University of Chinese Academy of Sciences, Liaoning Province Key Laboratory of Metabolomics, Dalian, Liaoning, 116023, P. R. China
| | - Chunxiu Hu
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), University of Chinese Academy of Sciences, Liaoning Province Key Laboratory of Metabolomics, Dalian, Liaoning, 116023, P. R. China
| | - Guowang Xu
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), University of Chinese Academy of Sciences, Liaoning Province Key Laboratory of Metabolomics, Dalian, Liaoning, 116023, P. R. China
| |
Collapse
|
2
|
Zhou W, Pawliszyn J. Perspective on SPME-MS: Green and high-performance methods for rapid screening. Anal Chim Acta 2024; 1291:342244. [PMID: 38280787 DOI: 10.1016/j.aca.2024.342244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2023] [Revised: 12/30/2023] [Accepted: 01/12/2024] [Indexed: 01/29/2024]
Abstract
The direct coupling of solid-phase microextraction (SPME) with mass spectrometry (MS) offers rapid analysis with high sensitivity and low matrix effects by benefiting from the integration of sampling, high enrichment, and clean-up functions of SPME. Eliminating chromatographic separation reduces the amount of gas/solvent needed for analysis, while direct desorption in SPME-MS consumes none or few microliters of organic solvents per sample, further enhancing the greenness of the SPME technology. Over the past two decades, the rapid evolution of SPME-MS has given rise to numerous novel technologies that employ diverse ionization techniques and interfaces, several of which have already been commercialized. Drawing from an extensive review published earlier this year and our research experience, we provide perspectives on three aspects of these technologies: interface design and automation, integration with state-of-art MS instrumentation, and anticipated future developments.
Collapse
Affiliation(s)
- Wei Zhou
- Department of Chemistry, University of Waterloo, Waterloo, ON, N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, ON, N2L 3G1, Canada.
| |
Collapse
|
3
|
Deng J, Xie J, Lu Q, Xiao X, Wu Y, Liu N, Luo L, Luan T, Yang Y. Nanospray Laser-Induced Plasma Ionization Mass Spectrometry for Rapid and Sensitive Analysis of Polycyclic Aromatic Hydrocarbons and Halogenated Derivatives. Anal Chem 2023; 95:16791-16795. [PMID: 37937882 DOI: 10.1021/acs.analchem.3c04378] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2023]
Abstract
Polycyclic aromatic hydrocarbons (PAHs) and halogenated derivatives are a series of environmental pollutants with potential toxicity and health risks on biosystems and the ecosystem. Rapid and sensitive analysis of trace PAHs and halogenated PAHs in complex environmental samples is a challenging topic for analytical science. Here we report the development of a nanospray laser-induced plasma ionization MS method for rapid and sensitive analysis of trace PAHs and halogenated PAHs under ambient and open-air conditions. A nanospray tip was applied for loading samples and placed pointing to the MS inlet, being a nanospray emitter with the application of a high voltage. A beam of laser was focused to induce energetic plasma between the nanospray emitter and the MS inlet for ionization of PAHs and halogenated PAHs for mass spectrometric analysis. Meanwhile, an inner-wall naphthyl-coated nanospray emitter was developed and applied as a solid-phase microextraction (SPME) probe for highly selective enrichment of trace PAHs and halogenated PAHs in complex environmental samples, and some organic solvent was applied to desorb the analytes for nanospray laser-induced plasma ionization MS analysis. Satisfactory linearity for each target PAH and halogenated PAH was obtained, with correlation coefficient values (r) no less than 0.9917. The method showed extremely high sensitivity for analysis of trace PAHs and halogenated PAHs in water, with limits of detection (LODs) and quantification (LOQs) of 0.0001-0.02 and 0.0003-0.08 μg/L, respectively. By using the inner-wall naphthyl-coated nanospray laser-induced plasma ionization MS method, sensitive detection of trace PAHs and halogenated PAHs in real sewage and wastewater samples was successfully achieved.
Collapse
Affiliation(s)
- Jiewei Deng
- School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, China
- Smart Medical Innovation Technology Center, Guangdong University of Technology, Guangzhou 510006, China
| | - Jialiang Xie
- School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, China
| | - Qiao Lu
- Department of Laboratory Medicine, Taihe Hospital, Hubei University of Medicine, Shiyan 442000, China
| | - Xu Xiao
- Biomedical Research Institute, Hubei University of Medicine, Shiyan 442000, China
| | - Yuehua Wu
- Guangdong Women and Children Hospital, Guangzhou 511400, China
| | - Ning Liu
- Guangdong Provincial Engineering Research Center for Ambient Mass Spectrometry, Guangdong Provincial Key Laboratory of Chemical Measurement and Emergency Test Technology, Institute of Analysis, Guangdong Academy of Sciences (China National Analytical Center, Guangzhou), 100 Xianlie Middle Road, Guangzhou 510070, China
| | - Lijuan Luo
- Guangdong Provincial Key Laboratory of Water Quality Improvement and Ecological Restoration for Watersheds, School of Ecology, Environment and Resources, Guangdong University of Technology, Guangzhou 510006, China
- Smart Medical Innovation Technology Center, Guangdong University of Technology, Guangzhou 510006, China
| | - Tiangang Luan
- School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, China
- School of Biotechnology and Health Sciences, Wuyi University, Jiangmen 529020, China
| | - Yunyun Yang
- Guangdong Provincial Engineering Research Center for Ambient Mass Spectrometry, Guangdong Provincial Key Laboratory of Chemical Measurement and Emergency Test Technology, Institute of Analysis, Guangdong Academy of Sciences (China National Analytical Center, Guangzhou), 100 Xianlie Middle Road, Guangzhou 510070, China
| |
Collapse
|
4
|
Guan X, Lu Q, Zhao X, Yan X, Zenobi R. Spatio-Temporal Analysis of Anesthetics in Mice by Solid-Phase Microextraction: Dielectric Barrier Discharge Ionization Mass Spectrometry. Anal Chem 2023; 95:12470-12477. [PMID: 37560898 DOI: 10.1021/acs.analchem.3c02123] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/11/2023]
Abstract
Local anesthetics, drugs that only affect a restricted area of the body, are widely used in daily clinical practice. Less studied but equally important is the distribution of local anesthetics inside organisms. Here, we present a rapid in situ testing method of drug distribution in various organs. The temporal and spatial distribution of anesthetics in mice was measured by solid-phase microextraction (SPME), thermal desorption (TD), and dielectric barrier discharge ionization (DBDI) atmospheric pressure mass spectrometry. A coated SPME probe using a tungsten wire as the support covered with a carbonaceous material was prepared by a simple, low-cost flame method. An in-line structure of the inlet allows TD and DBDI to share the same capillary tube, which greatly improves the transmission efficiency. Nine kinds of anesthetics, such as lidocaine and dyclonine, were detected, and the limit of detection was determined to be as low as 13 pg/mL. In addition, the time-dependent distribution of drugs in mice organs was studied. We also found that macromolecules in organisms do not noticeably interfere with the detection. This method is convenient and efficient because it does not require tissue homogenates and allows direct in situ detection. Compared with the conventional analytical methods, this method is simple and rapid, works in situ, and allows microscale analysis of trace analytes in biological organisms with high sensitivity.
Collapse
Affiliation(s)
- Xiaokang Guan
- Department of Chemistry and the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, and Discipline of Intelligent Instruments and Equipment, Xiamen University, Xiamen 361005, China
| | - Qiao Lu
- Department of Chemistry and the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, and Discipline of Intelligent Instruments and Equipment, Xiamen University, Xiamen 361005, China
- Department of Laboratory Medicine, Taihe Hospital, Hubei University of Medicine, Shiyan, Hubei 442000, China
| | - Xiangxu Zhao
- Department of Chemistry and the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, and Discipline of Intelligent Instruments and Equipment, Xiamen University, Xiamen 361005, China
| | - Xiaowen Yan
- Department of Chemistry and the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, and Discipline of Intelligent Instruments and Equipment, Xiamen University, Xiamen 361005, China
| | - Renato Zenobi
- Department of Chemistry and the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, and Discipline of Intelligent Instruments and Equipment, Xiamen University, Xiamen 361005, China
- Department of Chemistry and Applied Biosciences, ETH Zurich, Zurich CH-8093, Switzerland
| |
Collapse
|
5
|
Mirabelli MF. Direct Coupling of SPME to Mass Spectrometry. EVOLUTION OF SOLID PHASE MICROEXTRACTION TECHNOLOGY 2023:290-314. [DOI: 10.1039/bk9781839167300-00290] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
Abstract
Solid-phase microextraction devices are normally analyzed by gas or liquid chromatography. Their use has become increasingly widespread since their introduction in 1990, and nowadays most analytical laboratories use or have used SPME as an efficient and green method to perform analyte extraction and sample clean-up in one step. The SPME technique is intrinsically flexible, and allows for a high degree of optimization with regard to the extracting phase, as well as the way sample is analyzed. Since its introduction, researchers have been trying different ways to transfer analytes extracted from the solid phase to a mass spectrometer, with the aim to increase throughput and reduce solvent, gas usage and costs associated with conventional chromatographic techniques. Furthermore, but not less important, for pure fun of developing new, more efficient and sensitive analytical strategies! This chapter aims at providing a comprehensive overview of the most relevant non-chromatographic mass spectrometric approaches developed for SPME. Technical aspects of each SPME-MS approach will be discussed, highlighting their advantages, disadvantages and future potential developments. Particular emphasis will be given on the most recent direct coupling approaches using novel ionization approaches, and a concise overview of the existing applications will also be provided.
Collapse
|
6
|
Begley A, Zenobi R. Discriminating alkylbenzene isomers with tandem mass spectrometry using a dielectric barrier discharge ionization source. JOURNAL OF MASS SPECTROMETRY : JMS 2023; 58:e4910. [PMID: 36849135 DOI: 10.1002/jms.4910] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Revised: 02/05/2023] [Accepted: 02/08/2023] [Indexed: 06/18/2023]
Abstract
Soft ambient ionization sources generate reactive species that interact with analyte molecules to form intact molecular ions, which allows rapid, sensitive, and direct identification of the molecular mass. We used a dielectric barrier discharge ionization (DBDI) source with nitrogen at atmospheric pressure to detect alkylated aromatic hydrocarbon isomers (C8 H10 or C9 H12 ). Intact molecular ions [M]•+ were detected at 2.4 kVpp , but at increased voltage (3.4 kVpp ), [M + N]+ ions were formed, which could be used to differentiate regioisomers by collision-induced dissociation (CID). At 2.4 kVpp , alkylbenzene isomers with different alkyl-substituents could be identified by additional product ions: ethylbenzene and -toluene formed [M-2H]+ , isopropylbenzene formed abundant [M-H]+ , and propylbenzene formed abundant C7 H7 + . At an operating voltage of 3.4 kVpp , fragmentation of [M + N]+ by CID led to neutral loss of HCN and CH3 CN, which corresponded to steric hindrance for excited state N-atoms approaching the aromatic ring (C-H). The ratio of HCN to CH3 N loss (interday relative standard deviation [RSD] < 20%) was distinct for ethylbenzene and ethyltoluene isomers. The greater the number of alkyl-substituents (C-CH3 ) and the more sterically hindered (meta > para > ortho) the aromatic core, the greater the loss of CH3 CN relative to HCN was.
Collapse
Affiliation(s)
- Alina Begley
- Departement Chemie und Angewandte Biowissenschaften, ETH Zürich, Zürich, 8093, Switzerland
| | - Renato Zenobi
- Departement Chemie und Angewandte Biowissenschaften, ETH Zürich, Zürich, 8093, Switzerland
| |
Collapse
|
7
|
Yue H, He F, Zhao Z, Duan Y. Plasma-based ambient mass spectrometry: Recent progress and applications. MASS SPECTROMETRY REVIEWS 2023; 42:95-130. [PMID: 34128567 DOI: 10.1002/mas.21712] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2021] [Revised: 05/28/2020] [Accepted: 06/02/2020] [Indexed: 06/12/2023]
Abstract
Ambient mass spectrometry (AMS) has grown as a group of advanced analytical techniques that allow for the direct sampling and ionization of the analytes in different statuses from their native environment without or with minimum sample pretreatments. As a significant category of AMS, plasma-based AMS has gained a lot of attention due to its features that allow rapid, real-time, high-throughput, in vivo, and in situ analysis in various fields, including bioanalysis, pharmaceuticals, forensics, food safety, and mass spectrometry imaging. Tens of new methods have been developed since the introduction of the first plasma-based AMS technique direct analysis in real-time. This review first provides a comprehensive overview of the established plasma-based AMS techniques from their ion source configurations, mechanisms, and developments. Then, the progress of the representative applications in various scientific fields in the past 4 years (January 2017 to January 2021) has been summarized. Finally, we discuss the current challenges and propose the future directions of plasma-based AMS from our perspective.
Collapse
Affiliation(s)
- Hanlu Yue
- College of Life Sciences, Sichuan University, Chengdu, China
| | - Feiyao He
- College of Life Sciences, Sichuan University, Chengdu, China
| | - Zhongjun Zhao
- School of Chemical Engineering, Sichuan University, Chengdu, China
| | - Yixiang Duan
- College of Life Sciences, Sichuan University, Chengdu, China
- School of Manufacturing Science and Engineering, Sichuan University, Chengdu, China
| |
Collapse
|
8
|
Bouza M, García-Martínez J, Gilbert-López B, Brandt S, García-Reyes JF, Molina-Díaz A, Franzke J. Dielectric Barrier Discharge Ionization Mechanisms: Polycyclic Aromatic Hydrocarbons as a Case of Study. Anal Chem 2022; 95:854-861. [PMID: 36538370 PMCID: PMC9850405 DOI: 10.1021/acs.analchem.2c03279] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Dielectric barrier discharge ionization (DBDI) is a versatile tool for small-molecule mass spectrometry applications, helping cover from polar to low polar molecules. However, the plasma gas-phase interactions are highly complex and have been scarcely investigated. The ionization mechanisms of plasmas have long been assumed to be somewhat similar to atmospheric pressure chemical ionization (APCI). Here, we evaluated the ionization mechanisms of a two-ring DBDI ion source, using different discharge gases to analyze vaporized liquid samples. Polycyclic aromatic hydrocarbons (PAHs) were used as model analytes to assess the mechanisms' dominance: protonation, [M + H]+, or radical ion species formation, [M]·+. In the present work, two different ionization trends were observed for APCI and DBDI during the PAH analysis; the compounds with proton affinities (PA) over 856 kJ/mol were detected as [M + H]+ when APCI was used as ionization source. Meanwhile, independently of the PA, DBDI showed the prevalence of charge exchange reactions. The addition of dopants in the gas-phase region shifted the ionization mechanisms toward charge exchange reactions, facilitating the formation of [M]·+ ion species, showing anisole a significant boost of the PAH radical ion species signals, over nine times for Ar-Prop-DBDI analysis. The presence of high-energy metastable atoms (e.g., HeM) with high ionization potentials (IE = 19.80 eV) did not show boosted PAH abundances or extensive molecule fragmentation. Moreover, other species in the plasma jet region with closer and more appropriate IE, such as N2 B3Πg excited molecules, are likely responsible for PAH Penning ionization.
Collapse
Affiliation(s)
- Marcos Bouza
- Analytical
Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, 23071Jaén, Spain,. Phone: +34 953 212758
| | - Julio García-Martínez
- Analytical
Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, 23071Jaén, Spain
| | - Bienvenida Gilbert-López
- Analytical
Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, 23071Jaén, Spain
| | - Sebastian Brandt
- ISAS—Leibniz
Institut für Analytische Wissenschaften, Bunsen-Kirchhoff-Str. 11, 44139Dortmund, Germany
| | - Juan F. García-Reyes
- Analytical
Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, 23071Jaén, Spain
| | - Antonio Molina-Díaz
- Analytical
Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, 23071Jaén, Spain
| | - Joachim Franzke
- ISAS—Leibniz
Institut für Analytische Wissenschaften, Bunsen-Kirchhoff-Str. 11, 44139Dortmund, Germany,. Phone: +49 0231 1392-174
| |
Collapse
|
9
|
Guo X, Pu J, Dai J, Zhao Z, Duan Y. Elucidation of formation mechanism responsible for charge-transfer reagent ions in microwave induced plasma desorption ionization (MIPDI) source. Talanta 2022; 250:123656. [DOI: 10.1016/j.talanta.2022.123656] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Revised: 05/30/2022] [Accepted: 06/03/2022] [Indexed: 11/29/2022]
|
10
|
Liu Q, Lan J, Wu R, Begley A, Ge W, Zenobi R. Hybrid Ionization Source Combining Nanoelectrospray and Dielectric Barrier Discharge Ionization for the Simultaneous Detection of Polar and Nonpolar Compounds in Single Cells. Anal Chem 2022; 94:2873-2881. [PMID: 35113514 DOI: 10.1021/acs.analchem.1c04759] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Single-cell metabolomics is expected to deliver fast and dynamic information on cell function; therefore, it requires rapid analysis of a wide variety of very small quantities of metabolites in living cells. In this work, a hybrid ionization source that combines nanoelectrospray ionization (nanoESI) and dielectric barrier discharge ionization (DBDI) is proposed for single-cell analysis. A capillary with a 1 μm i.d. tip was inserted into cells for sampling and then directly used as the nanoESI source for ionization of polar metabolites. In addition, a DBDI source was employed as a post-ionization source to improve the ionization of apolar metabolites in cells that are not easily ionized by ESI. By increasing the voltage of the DBDI source from 0 to 3.2 kV, the classes of detected metabolites can be shifted from mostly polar to both polar and apolar to mainly apolar. Plant cells (onion) and human cells (PANC-1) were investigated in this study. After optimization, 50 compounds in onion cells and 40 compounds in PANC-1 cells were observed in ESI mode (3.5 kV) and an additional 49 compounds in onion cells and 73 compounds in PANC-1 cells were detected in ESI (3.5 kV)-DBDI (2.6 kV) hybrid mode. This hybrid ionization source improves the coverage, ionization efficiency, and limit of detection of metabolites with different polarities and could potentially contribute to the fast-growing field of single-cell metabolomics.
Collapse
Affiliation(s)
- Qinlei Liu
- Department of Chemistry and Applied Biosciences, ETH Zurich, CH-8093 Zurich, Switzerland
| | - Jiayi Lan
- Department of Chemistry and Applied Biosciences, ETH Zurich, CH-8093 Zurich, Switzerland
| | - Ri Wu
- Department of Chemistry and Applied Biosciences, ETH Zurich, CH-8093 Zurich, Switzerland
| | - Alina Begley
- Department of Chemistry and Applied Biosciences, ETH Zurich, CH-8093 Zurich, Switzerland
| | - Wenjie Ge
- Department of Biology, ETH Zurich, CH-8093 Zurich, Switzerland
| | - Renato Zenobi
- Department of Chemistry and Applied Biosciences, ETH Zurich, CH-8093 Zurich, Switzerland
| |
Collapse
|
11
|
Alhendal A, Almoaeen RA, Rashad M, Husain A, Mouffouk F, Ahmad Z. Aramid-wrapped CNT hybrid sol–gel sorbent for polycyclic aromatic hydrocarbons. RSC Adv 2022; 12:18077-18083. [PMID: 35800310 PMCID: PMC9207600 DOI: 10.1039/d2ra02659g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Accepted: 06/02/2022] [Indexed: 11/21/2022] Open
Abstract
This work describes the preparation of an analytical microextraction sorbent using a simple and versatile sol–gel hybrid composite, i.e., aramid oligomers wrapping multi-walled carbon nanotubes (CNTs) covalently bonded to a porous silica network.
Collapse
Affiliation(s)
- Abdullah Alhendal
- Department of Chemistry, Kuwait University, P. O. Box 5969, Safat, 13060, Kuwait
| | - Randa Abd Almoaeen
- Department of Chemistry, Kuwait University, P. O. Box 5969, Safat, 13060, Kuwait
| | - Mohamed Rashad
- Department of Chemistry, Kuwait University, P. O. Box 5969, Safat, 13060, Kuwait
| | - Ali Husain
- Department of Chemistry, Kuwait University, P. O. Box 5969, Safat, 13060, Kuwait
| | - Fouzi Mouffouk
- Department of Chemistry, Kuwait University, P. O. Box 5969, Safat, 13060, Kuwait
| | - Zahoor Ahmad
- Department of Chemistry, Kuwait University, P. O. Box 5969, Safat, 13060, Kuwait
| |
Collapse
|
12
|
Liu Q, Ge W, Wang T, Lan J, Martínez‐Jarquín S, Wolfrum C, Stoffel M, Zenobi R. High‐Throughput Single‐Cell Mass Spectrometry Reveals Abnormal Lipid Metabolism in Pancreatic Ductal Adenocarcinoma. Angew Chem Int Ed Engl 2021. [DOI: 10.1002/ange.202107223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Affiliation(s)
- Qinlei Liu
- Department of Chemistry and Applied Biosciences ETH Zurich Vladimir-Prelog-Weg 3 8093 Zurich Switzerland
| | - Wenjie Ge
- Department of Biology ETH Zurich Otto-Stern-Weg 7 8093 Zurich Switzerland
| | - Tongtong Wang
- Department of Health Sciences and Technology ETH Zurich Schorenstrasse 16 8603 Schwerzenbach Switzerland
| | - Jiayi Lan
- Department of Chemistry and Applied Biosciences ETH Zurich Vladimir-Prelog-Weg 3 8093 Zurich Switzerland
| | - Sandra Martínez‐Jarquín
- Department of Chemistry and Applied Biosciences ETH Zurich Vladimir-Prelog-Weg 3 8093 Zurich Switzerland
| | - Christian Wolfrum
- Department of Health Sciences and Technology ETH Zurich Schorenstrasse 16 8603 Schwerzenbach Switzerland
| | - Markus Stoffel
- Department of Biology ETH Zurich Otto-Stern-Weg 7 8093 Zurich Switzerland
| | - Renato Zenobi
- Department of Chemistry and Applied Biosciences ETH Zurich Vladimir-Prelog-Weg 3 8093 Zurich Switzerland
| |
Collapse
|
13
|
Liu Q, Ge W, Wang T, Lan J, Martínez‐Jarquín S, Wolfrum C, Stoffel M, Zenobi R. High-Throughput Single-Cell Mass Spectrometry Reveals Abnormal Lipid Metabolism in Pancreatic Ductal Adenocarcinoma. Angew Chem Int Ed Engl 2021; 60:24534-24542. [PMID: 34505339 PMCID: PMC8597026 DOI: 10.1002/anie.202107223] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2021] [Revised: 08/17/2021] [Indexed: 01/02/2023]
Abstract
Even populations of clonal cells are heterogeneous, which requires high-throughput analysis methods with single-cell sensitivity. Here, we propose a rapid, label-free single-cell analytical method based on active capillary dielectric barrier discharge ionization mass spectrometry, which can analyze multiple metabolites in single cells at a rate of 38 cells/minute. Multiple cell types (HEK-293T, PANC-1, CFPAC-1, H6c7, HeLa and iBAs) were discriminated successfully. We found evidence for abnormal lipid metabolism in pancreatic cancer cells. We also analyzed gene expression in a cancer genome atlas dataset and found that the mRNA level of a critical enzyme of lipid synthesis (ATP citrate lyase, ACLY) was upregulated in human pancreatic ductal adenocarcinoma (PDAC). Moreover, both an ACLY chemical inhibitor and a siRNA approach targeting ACLY could suppress the viability of PDAC cells. A significant reduction in lipid content in treated cells indicates that ACLY could be a potential target for treating pancreatic cancer.
Collapse
Affiliation(s)
- Qinlei Liu
- Department of Chemistry and Applied BiosciencesETH ZurichVladimir-Prelog-Weg 38093ZurichSwitzerland
| | - Wenjie Ge
- Department of BiologyETH ZurichOtto-Stern-Weg 78093ZurichSwitzerland
| | - Tongtong Wang
- Department of Health Sciences and TechnologyETH ZurichSchorenstrasse 168603SchwerzenbachSwitzerland
| | - Jiayi Lan
- Department of Chemistry and Applied BiosciencesETH ZurichVladimir-Prelog-Weg 38093ZurichSwitzerland
| | - Sandra Martínez‐Jarquín
- Department of Chemistry and Applied BiosciencesETH ZurichVladimir-Prelog-Weg 38093ZurichSwitzerland
| | - Christian Wolfrum
- Department of Health Sciences and TechnologyETH ZurichSchorenstrasse 168603SchwerzenbachSwitzerland
| | - Markus Stoffel
- Department of BiologyETH ZurichOtto-Stern-Weg 78093ZurichSwitzerland
| | - Renato Zenobi
- Department of Chemistry and Applied BiosciencesETH ZurichVladimir-Prelog-Weg 38093ZurichSwitzerland
| |
Collapse
|
14
|
Gao Y, Li Y, Zhan B, He Q, Zhu H, Chen W, Yin Q, Feng H, Pan Y. Ambient electric arc ionization for versatile sample analysis using mass spectrometry. Analyst 2021; 146:5682-5690. [PMID: 34397059 DOI: 10.1039/d1an00872b] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A novel, convenient ambient electric arc ionization (AEAI) device was developed as a mass spectrometry ion source for versatile sample analysis. AEAI could be considered as a soft ionization technique in which the protonated ion ([M + H]+) is the main ion species with little or no in-source fragmentation for most analytes. Coupled with a high-resolution Orbitrap mass spectrometer, AEAI could be applied to the analysis of a variety of organic compounds having a wide range of polarities, ranging from non-polar species such as polybenzenoid aromatic hydrocarbons (PAHs) to highly polar species such as amino acids. With its versatile capabilities in the mass spectrometric analysis of small molecules, AEAI has the potential to be an alternative to traditional ionization methods such as electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI), and electron impact (EI) ionization. The limitations of AEAI are also discussed.
Collapse
Affiliation(s)
- Yuanji Gao
- Department of Chemistry, Zhejiang University, Hangzhou 310027, Zhejiang, P. R. China. .,College of Chemistry and Materials Science, Sichuan Normal University, Chengdu 610068, Sichuan, P.R. China
| | - Yuan Li
- Department of Chemistry, Zhejiang University, Hangzhou 310027, Zhejiang, P. R. China.
| | - Binpeng Zhan
- Department of Chemistry, Zhejiang University, Hangzhou 310027, Zhejiang, P. R. China.
| | - Quan He
- Department of Chemistry, Zhejiang University, Hangzhou 310027, Zhejiang, P. R. China.
| | - Heping Zhu
- Department of Chemistry, Zhejiang University, Hangzhou 310027, Zhejiang, P. R. China.
| | - Weiwei Chen
- Department of Chemistry, Zhejiang University, Hangzhou 310027, Zhejiang, P. R. China.
| | - Qi Yin
- Department of Chemistry, Zhejiang University, Hangzhou 310027, Zhejiang, P. R. China.
| | - Hongru Feng
- Department of Chemistry, Zhejiang University, Hangzhou 310027, Zhejiang, P. R. China.
| | - Yuanjiang Pan
- Department of Chemistry, Zhejiang University, Hangzhou 310027, Zhejiang, P. R. China.
| |
Collapse
|
15
|
Weber M, Wolf JC, Haisch C. Gas Chromatography-Atmospheric Pressure Inlet-Mass Spectrometer Utilizing Plasma-Based Soft Ionization for the Analysis of Saturated, Aliphatic Hydrocarbons. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:1707-1715. [PMID: 34170138 DOI: 10.1021/jasms.0c00476] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Soft ionization by a chemical reaction in transfer (SICRIT) is applied to couple gas chromatography (GC) to a high-resolution atmospheric pressure inlet mass spectrometer. These instruments are generally used in combination with liquid chromatography systems (LC-MS). Ionization of alkanes is not possible here with conventional electrospray ionization. Alternatively, separate GC-electron ionization (EI)-MS is employed for the analysis of nonpolar substances like alkanes, however, with the inherent challenge of strong fragmentation. In the case of alkanes, the determination of molecular masses becomes nearly impossible in complex hydrocarbon mixtures because of the wealth of similar fragment ions and the absence of the molecular ion signal. SICRIT, a soft ionization technique based on dielectric barrier discharge (DBDI), produces characteristic oxidized cations from alkanes that can be directly correlated to their molecular mass. Isotope labeling experiments reveal an ionization mechanism via hydride abstraction and reaction with water. Soft ionization can be achieved for iso- and n-alkanes, with very little fragmentation, enabling the determination of their molecular mass. Calibrations for n-alkanes from C10 to C30 were performed exhibiting high linearity, reproducibility, and sensitivity with an average LOD of 69 pg (on column). Measurements of diesel fuel samples are compared to traditional GC-EI-MS. The presented method combines sensitivity and easy handling of a GC-EI-MS with the determination of molecular mass commonly only achieved with field ionization (FI)-MS, while using existing and highly optimized mass spectrometers commonly coupled with LC. Additionally, many other analytes such as (alkylated-) PAHs could be detected simultaneously in the diesel sample.
Collapse
Affiliation(s)
- Markus Weber
- Department of Analytical Chemistry and Water Chemistry, Technical University of Munich, 81377 Munich, Germany
- Plasmion GmbH, 86167 Augsburg, Germany
| | | | - Christoph Haisch
- Department of Analytical Chemistry and Water Chemistry, Technical University of Munich, 81377 Munich, Germany
| |
Collapse
|
16
|
Brecht D, Uteschil F, Schmitz OJ. Development of an inverse low-temperature plasma ionization source for liquid chromatography/mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2021; 35:e9071. [PMID: 33625792 DOI: 10.1002/rcm.9071] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Revised: 02/17/2021] [Accepted: 02/19/2021] [Indexed: 06/12/2023]
Abstract
RATIONALE An argon inverse low-temperature plasma (iLTP) ionization source for liquid chromatography/tandem mass spectrometry was developed. The iLTP is constructed from simple chromatographic supply materials and is implemented into an atmospheric pressure chemical ionization (APCI) source replacing the APCI discharge needle electrode. The newly developed ion source was coupled to an ultra-high-performance liquid chromatography (UHPLC) system. METHODS The argon iLTP was characterized by optical emission spectroscopy. The soft ionization of selected standards was also demonstrated by direct infusion experiments. In addition to the use of argon as the discharge gas, helium, synthetic air, and oxygen were used, which were tested for their performance using testosterone and vitamin D3 . RESULTS Spectroscopic measurements of the argon plasma were conducted, demonstrating the main emission band of argon metastables with corresponding energies of 11.53 eV and 11.72 eV. Infusion experiments indicate a gentle ionization by iLTP, e.g. caffeine, testosterone, reserpine, vitamin D3 , and 25-hydroxyvitamin D3 , which resulted in the corresponding protonated molecules. The splitless coupling with UHPLC (possible flow rates >1000 μL min-1 ) shows promising results in interday repeatability (n = 10) for the substances with a relative standard deviation of less than 5% and limits of detection for caffeine, testosterone, reserpine, vitamin D3 , and 25-hydroxyvitamin D3 of 10 ng L-1 , 50 ng L-1 , 500 ng L-1 , 5 μg L-1 , and 5 μg L-1 , respectively. CONCLUSIONS The argon iLTP ion source presented in this work shows promising approaches in the field of ionization of small organic molecules. The mechanism related to the discharge gas argon has not been elucidated so far and further investigations are needed. The iLTP ion source shows a very good performance with UHPLC coupling, even at increased flow rates. It could be shown that an argon iLTP can compete with the helium dielectric barrier discharge (DBD) preferred in the literature, making it a more economical choice.
Collapse
Affiliation(s)
- Dominik Brecht
- Department of Applied Analytical Chemistry, University of Duisburg-Essen, Universitaetsstrasse 5, Essen, 45141, Germany
| | - Florian Uteschil
- Department of Applied Analytical Chemistry, University of Duisburg-Essen, Universitaetsstrasse 5, Essen, 45141, Germany
| | - Oliver J Schmitz
- Department of Applied Analytical Chemistry, University of Duisburg-Essen, Universitaetsstrasse 5, Essen, 45141, Germany
| |
Collapse
|
17
|
He J, Wang W, Zhang H, Ju Y, Yu K, Zhang X, Jiang J. Nebulization dielectric barrier discharge ionization mass spectrometry: Rapid and sensitive analysis of acenaphthene. Talanta 2021; 222:121681. [PMID: 33167287 DOI: 10.1016/j.talanta.2020.121681] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 09/05/2020] [Accepted: 09/14/2020] [Indexed: 01/30/2023]
Abstract
A rapid, simple and sensitive method was proposed for low-polar acenaphthene analysis by coupling nebulization with dielectric barrier discharge ionization (N-DBDI). The sample solution was nebulized followed by heating and converted to be gas-phase analyte molecules prior to DBDI. This boosts the collision efficiency of analyte molecules with reactive species and thus the sensitivity, and the high-velocity gas from nebulization guides ions directed to the MS inlet without deflection. The dependence of sensitivity on the operation parameters was systematically investigated. The LOD and LOQ of acenaphthene were determined to be 0.61 ng/L and 2.05 ng/L, respectively, which were superior approximately 30 folds compared to those obtained by other methods. Parameters, including accuracy, precision, reproducibility and utility, were tested to further evaluate the performance of N-DBDI. Real environmental samples, including river water, initial rainwater and mineral water, were analyzed with good accuracy (93.61-103.50%) and satisfactory precision (RSD ≤ 8.92%). These findings suggest that the N-DBDI allows the determination of non/low-polar species at sub-pg/mL possible, and would benefit for the non/low-polar species analysis in real environmental samples.
Collapse
Affiliation(s)
- Jing He
- State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin, Heilongjiang, 150090, PR China; School of Marine Science and Technology, Harbin Institute of Technology at Weihai, Weihai, Shandong, 264209, PR China; School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin, Heilongjiang, 150090, PR China
| | - Wenxin Wang
- State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin, Heilongjiang, 150090, PR China; School of Marine Science and Technology, Harbin Institute of Technology at Weihai, Weihai, Shandong, 264209, PR China
| | - Hong Zhang
- State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin, Heilongjiang, 150090, PR China; School of Marine Science and Technology, Harbin Institute of Technology at Weihai, Weihai, Shandong, 264209, PR China.
| | - Yun Ju
- State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin, Heilongjiang, 150090, PR China; School of Marine Science and Technology, Harbin Institute of Technology at Weihai, Weihai, Shandong, 264209, PR China; School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin, Heilongjiang, 150090, PR China
| | - Kai Yu
- State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin, Heilongjiang, 150090, PR China; School of Marine Science and Technology, Harbin Institute of Technology at Weihai, Weihai, Shandong, 264209, PR China
| | - Xiangnan Zhang
- State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin, Heilongjiang, 150090, PR China; School of Marine Science and Technology, Harbin Institute of Technology at Weihai, Weihai, Shandong, 264209, PR China; School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin, Heilongjiang, 150090, PR China
| | - Jie Jiang
- State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin, Heilongjiang, 150090, PR China; School of Marine Science and Technology, Harbin Institute of Technology at Weihai, Weihai, Shandong, 264209, PR China.
| |
Collapse
|
18
|
Mirabelli MF, Zenobi R. Rapid screening and quantitation of PAHs in water and complex sample matrices by solid-phase microextraction coupled to capillary atmospheric pressure photoionization-mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2021; 56:e4656. [PMID: 32975320 DOI: 10.1002/jms.4656] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Revised: 08/31/2020] [Accepted: 09/05/2020] [Indexed: 06/11/2023]
Abstract
A capillary atmospheric pressure photoionization (cAPPI) source was used to analyze polycyclic aromatic hydrocarbons (PAHs) in complex matrices like grilled meat extract and urban dust reference material, as well as screening for PAHs in aqueous samples such as tap and lake water. A high-throughput workflow was developed that allowed rapid screening of unknown samples by direct solid-phase microextraction (SPME) coupled with cAPPI-MS, with confirmatory gas chromatography performed only for samples containing trace amounts of PAHs. Extraction times were as low as 15 s, with a total analysis time of 2 min per sample for screening. Limits of detections were in the low pg/ml range and in the subpg/ml range for the direct and chromatographic approach, respectively, with a linear dynamic range between two and three orders of magnitude, as determined for 15 model PAHs. This rapid approach represents an attractive way to screen samples containing nonpolar compounds using an ambient ionization source.
Collapse
Affiliation(s)
- Mario F Mirabelli
- Department of Chemistry and Applied Biosciences, ETH Zurich, Zurich, 8093, Switzerland
- CTC Analytics AG, Industriestrasse 20, Zwingen, 4222, Switzerland
| | - Renato Zenobi
- Department of Chemistry and Applied Biosciences, ETH Zurich, Zurich, 8093, Switzerland
| |
Collapse
|
19
|
Wang Z, Cao Y, Lu Y, Zhang F, Su Y, Guo Y. Ultrasonic extraction and nebulization in real-time coupled with carbon fiber ionization mass spectrometry for rapid screening of the synthetic drugs adulterated into herbal products. Anal Chim Acta 2020; 1136:62-71. [DOI: 10.1016/j.aca.2020.08.045] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2020] [Accepted: 08/24/2020] [Indexed: 12/14/2022]
|
20
|
Zhu SZ, Zhang L, Zhang J, Guo YL. Arc Plasma-Based Dissociation Device: Fingerprinting Mass Spectrometric Analysis Realized at Atmospheric Condition. Anal Chem 2020; 92:14633-14639. [DOI: 10.1021/acs.analchem.0c03127] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Affiliation(s)
- Su-zhen Zhu
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Center for Excellence in Molecular Synthesis, Shanghai Institute of Organic Chemistry, University of Chinese Academy of Sciences, Chinese Academy of Sciences, 345 Lingling Road, Shanghai 200032, China
| | - Li Zhang
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Center for Excellence in Molecular Synthesis, Shanghai Institute of Organic Chemistry, University of Chinese Academy of Sciences, Chinese Academy of Sciences, 345 Lingling Road, Shanghai 200032, China
| | - Jing Zhang
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Center for Excellence in Molecular Synthesis, Shanghai Institute of Organic Chemistry, University of Chinese Academy of Sciences, Chinese Academy of Sciences, 345 Lingling Road, Shanghai 200032, China
| | - Yin-long Guo
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Center for Excellence in Molecular Synthesis, Shanghai Institute of Organic Chemistry, University of Chinese Academy of Sciences, Chinese Academy of Sciences, 345 Lingling Road, Shanghai 200032, China
| |
Collapse
|
21
|
Meisenbichler C, Kluibenschedl F, Müller T. A 3-in-1 Hand-Held Ambient Mass Spectrometry Interface for Identification and 2D Localization of Chemicals on Surfaces. Anal Chem 2020; 92:14314-14318. [PMID: 33063994 PMCID: PMC7643069 DOI: 10.1021/acs.analchem.0c02615] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
![]()
Desorption electrospray ionization
(DESI), easy ambient sonic-spray
ionization (EASI) and low-temperature plasma (LTP) ionization are
powerful ambient ionization techniques for mass spectrometry. However,
every single method has its limitation in terms of polarity and molecular
weight of analyte molecules. After the miniaturization of every possible
component of the different ion sources, we finally were able to embed
two emitters and an ion transfer tubing into a small, hand-held device.
The pen-like interface is connected to the mass spectrometer and a
separate control unit via a bundle of flexible tubing and cables.
The novel device allows the user to ionize an extended range of chemicals
by simple switching between DESI, voltage-free EASI, or LTP ionization
as well as to freely move the interface over a surface of interest.
A mini camera, which is mounted on the tip of the pen, magnifies the
desorption area and enables a simple positioning of the pen. The interface
was successfully tested using different types of chemicals, pharmaceuticals,
and real life samples. Moreover, the combination of optical data from
the camera module and chemical data obtained by mass analysis facilitates
a novel type of imaging mass spectrometry, which we name “interactive
mass spectrometry imaging (IMSI)”.
Collapse
Affiliation(s)
- Christina Meisenbichler
- Institute of Organic Chemistry, Leopold-Franzens University Innsbruck, 6020 Innsbruck, Austria
| | - Florian Kluibenschedl
- Institute of Organic Chemistry, Leopold-Franzens University Innsbruck, 6020 Innsbruck, Austria
| | - Thomas Müller
- Institute of Organic Chemistry, Leopold-Franzens University Innsbruck, 6020 Innsbruck, Austria
| |
Collapse
|
22
|
Hajializadeh A, Ansari M, Foroughi MM, Kazemipour M. Ultrasonic assisted synthesis of a novel ternary nanocomposite based on carbon nanotubes/zeolitic imidazolate framework-67/polyaniline for solid-phase microextraction of organic pollutants. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105008] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
23
|
Ruiz-Jimenez J, Lan H, Leleev Y, Hartonen K, Riekkola ML. Comparison of multiple calibration approaches for the determination of volatile organic compounds in air samples by solid phase microextraction Arrow and in-tube extraction. J Chromatogr A 2020; 1616:460825. [DOI: 10.1016/j.chroma.2019.460825] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2019] [Revised: 12/16/2019] [Accepted: 12/21/2019] [Indexed: 02/06/2023]
|
24
|
Lu Q, Lin R, Du C, Meng Y, Yang M, Zenobi R, Hang W. Metal Probe Microextraction Coupled to Dielectric Barrier Discharge Ionization–Mass Spectrometry for Detecting Drug Residues in Organisms. Anal Chem 2020; 92:5921-5928. [DOI: 10.1021/acs.analchem.0c00004] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Affiliation(s)
- Qiao Lu
- Department of Chemistry and the MOE Key Lab of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Rongkun Lin
- Department of Chemistry and the MOE Key Lab of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Chao Du
- Department of Chemistry and the MOE Key Lab of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Yifan Meng
- Department of Chemistry and the MOE Key Lab of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Manqing Yang
- Department of Chemistry and the MOE Key Lab of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Renato Zenobi
- Department of Chemistry and the MOE Key Lab of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
- ETH Zurich, Department of Chemistry and Applied Biosciences, 8093 Zurich, Switzerland
| | - Wei Hang
- Department of Chemistry and the MOE Key Lab of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| |
Collapse
|
25
|
Abstract
Thirty years since the invention and public disclosure of solid phase microextraction (SPME), the technology continues evolving and inspiring several other green extraction technologies amenable for the collection of small molecules present in complex matrices. In this manuscript, we review the fundamental and operational aspects of a novel SPME geometry that can be used to “hunt” target molecules in complex matrices: the SPME Arrow. In addition, a series of applications in environmental, food, cannabis and forensic analysis are succinctly covered. Finally, special emphasis is placed on novel interfaces to analytical instrumentation, as well as recent developments in coating materials for the SPME Arrow.
Collapse
|
26
|
Li Y, Cao Y, Guo Y. Recent Advances in Atmospheric Ionization Mass Spectrometry: Developments and Applications. CHINESE J CHEM 2019. [DOI: 10.1002/cjoc.201900359] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- Yuling Li
- State Key Laboratory of Organometallic Chemistry, National Center for Organic Mass Spectrometry in ShanghaiShanghai Institute of Organic Chemistry, Chinese Academy of Sciences Shanghai 200032 China
| | - Yuqi Cao
- State Key Laboratory of Organometallic Chemistry, National Center for Organic Mass Spectrometry in ShanghaiShanghai Institute of Organic Chemistry, Chinese Academy of Sciences Shanghai 200032 China
| | - Yinlong Guo
- State Key Laboratory of Organometallic Chemistry, National Center for Organic Mass Spectrometry in ShanghaiShanghai Institute of Organic Chemistry, Chinese Academy of Sciences Shanghai 200032 China
| |
Collapse
|
27
|
Solvent-free high-throughput analysis of herbicides in environmental water. Anal Chim Acta 2019; 1071:8-16. [DOI: 10.1016/j.aca.2019.04.024] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2019] [Revised: 03/20/2019] [Accepted: 04/10/2019] [Indexed: 12/13/2022]
|
28
|
Wang X, Jia R, Song Y, Wang M, Zhao Q, Sun S. Determination of pesticides and their degradation products in water samples by solid-phase extraction coupled with liquid chromatography-mass spectrometry. Microchem J 2019. [DOI: 10.1016/j.microc.2019.104013] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
29
|
Thermal decomposition tandem mass spectrometry for rapid detection of tetrabromobisphenol A bis(allyl ether) in soils. Talanta 2019; 200:373-377. [DOI: 10.1016/j.talanta.2019.03.065] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2019] [Revised: 03/09/2019] [Accepted: 03/16/2019] [Indexed: 11/18/2022]
|
30
|
Huba AK, Mirabelli MF, Zenobi R. Understanding and Optimizing the Ionization of Polycyclic Aromatic Hydrocarbons in Dielectric Barrier Discharge Sources. Anal Chem 2019; 91:10694-10701. [DOI: 10.1021/acs.analchem.9b02044] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Affiliation(s)
- Anna Katarina Huba
- Department of Chemistry and Applied Biosciences, ETH Zürich, CH-8093 Zürich, Switzerland
| | - Mario F. Mirabelli
- Department of Chemistry and Applied Biosciences, ETH Zürich, CH-8093 Zürich, Switzerland
| | - Renato Zenobi
- Department of Chemistry and Applied Biosciences, ETH Zürich, CH-8093 Zürich, Switzerland
| |
Collapse
|
31
|
Lee JY, Kim WS, Lee YY, Choi YS, Choi H, Jang HW. Solid-phase microextraction Arrow for the volatile organic compounds in soy sauce. J Sep Sci 2019; 42:2942-2948. [PMID: 31268227 DOI: 10.1002/jssc.201900388] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2019] [Revised: 06/05/2019] [Accepted: 07/01/2019] [Indexed: 01/28/2023]
Abstract
A novel solid-phase microextraction Arrow was used to separate volatile organic compounds from soy sauce, and the results were verified by using gas chromatography with mass spectrometry. Solid-phase microextraction Arrow was optimized in terms of three extraction conditions: type of fiber used (polydimethylsiloxane, polyacrylate, carbon wide range/polydimethylsiloxane, and divinylbenzene/polydimethylsiloxane), extraction temperature (40, 50, and 60°C), and extraction time (10, 30, and 60 min). The optimal solid-phase microextraction Arrow conditions were as follows: type of fiber = polyacrylate, extraction time = 60 min, and extraction temperature = 50°C. Under the optimized conditions, the solid-phase microextraction Arrow was compared with conventional solid-phase microextraction to determine extraction yields. The solid-phase microextraction Arrow yielded 6-42-fold higher levels than in solid-phase microextraction for all 21 volatile organic compounds detected in soy sauce due to the larger sorption phase volume. The findings of this study can provide practical guidelines for solid-phase microextraction Arrow applications in food matrixes by providing analytical methods for volatile organic compounds.
Collapse
Affiliation(s)
- Jun-Young Lee
- Korea Food Research Institute, Wanju-Gun, Jeollabuk-do, Republic of Korea
| | - Woo Seok Kim
- Thermo Fisher Scientific Korea, Gangnam-gu, Seoul, Republic of Korea
| | - Yun-Yeol Lee
- Korea Food Research Institute, Wanju-Gun, Jeollabuk-do, Republic of Korea
| | - Yun-Sang Choi
- Korea Food Research Institute, Wanju-Gun, Jeollabuk-do, Republic of Korea
| | - Hyunwook Choi
- Korea Food Research Institute, Wanju-Gun, Jeollabuk-do, Republic of Korea
| | - Hae Won Jang
- Korea Food Research Institute, Wanju-Gun, Jeollabuk-do, Republic of Korea
| |
Collapse
|
32
|
Antoniadou M, Zachariadis GA, Rosenberg E. Investigating the performance characteristics of the barrier discharge ionization detector and comparison to the flame ionization detector for the gas chromatographic analysis of volatile and semivolatile organic compounds. ANAL LETT 2019. [DOI: 10.1080/00032719.2019.1628247] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Affiliation(s)
- Maria Antoniadou
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University, Thessaloniki, Greece
- Institute of Chemical Technology and Analytics, Vienna University of Technology, Vienna, Austria
| | - George A. Zachariadis
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University, Thessaloniki, Greece
| | - Erwin Rosenberg
- Institute of Chemical Technology and Analytics, Vienna University of Technology, Vienna, Austria
| |
Collapse
|
33
|
Feider CL, Krieger A, DeHoog RJ, Eberlin LS. Ambient Ionization Mass Spectrometry: Recent Developments and Applications. Anal Chem 2019; 91:4266-4290. [PMID: 30790515 PMCID: PMC7444024 DOI: 10.1021/acs.analchem.9b00807] [Citation(s) in RCA: 262] [Impact Index Per Article: 52.4] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Clara L. Feider
- Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Anna Krieger
- Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Rachel J. DeHoog
- Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Livia S. Eberlin
- Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712, United States
| |
Collapse
|
34
|
|
35
|
Mirabelli MF, Gionfriddo E, Pawliszyn J, Zenobi R. Fast screening of illicit drugs in beverages and biological fluids by direct coupling of thin film microextraction to dielectric barrier discharge ionization-mass spectrometry. Analyst 2019; 144:2788-2796. [DOI: 10.1039/c8an02448k] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
A direct and fast method for quantification of illicit drugs in beverages and biological fluids was developed, using dielectric barrier discharge ionization in combination with high-resolution MS.
Collapse
Affiliation(s)
- Mario F. Mirabelli
- ETH Zurich
- Department of Chemistry and Applied Biosciences
- 8093 Zurich
- Switzerland
| | | | | | - Renato Zenobi
- ETH Zurich
- Department of Chemistry and Applied Biosciences
- 8093 Zurich
- Switzerland
| |
Collapse
|