1
|
Jiao D, Zhang R, Wang M, Zhang X, Ma H, Li M, Chang H. Compact photometric detector integrated with separation microchip for potential portable liquid chromatography system. J Chromatogr A 2024; 1731:465175. [PMID: 39032217 DOI: 10.1016/j.chroma.2024.465175] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2024] [Revised: 07/10/2024] [Accepted: 07/15/2024] [Indexed: 07/22/2024]
Abstract
In recent years, miniaturized analytical instruments have been developing to meet the needs of portable and rapid analysis. The key of miniaturized analytical equipment is the miniaturization and integration of functional modules. This paper aims to develop a miniaturized photometric detector and separation microfluidic chip for a liquid chromatography (LC) system. The detector uses a light-emitting diode to emit ultraviolet light, which is collimated by an internal double lens. A Z-shaped flow cell with a long optical path is designed and fabricated in the separation microfluidic chip with a three-layer structure, which provides a tubing-free connection between the separation and detection unit. Detector performance is evaluated using hemoglobin (Hb) samples, with an upper limit of detection linearity (95 %) of 0.345 AU and stray light level as low as 0.08 %. Additionally, the microchip channel can be filled with cation exchange resin and C18 particles. Finally, an ion LC system and a reversed-phase LC system were constructed based on the miniaturized photometric detector and two microchips with different packed columns, respectively, and were successfully used in the separation and detection of two metabolic markers (glycated hemoglobin or bilirubin). The results of this study are expected to facilitate the development of a portable LC system and their application in community health services and family health management of chronic diseases.
Collapse
Affiliation(s)
- Dezhao Jiao
- The Ministry of Education Key Laboratory of Micro/Nano Systems for Aerospace, Department of Microsystem Engineering, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an 710072, China
| | - Ruirong Zhang
- The Ministry of Education Key Laboratory of Micro/Nano Systems for Aerospace, Department of Microsystem Engineering, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an 710072, China.
| | - Mengbo Wang
- The Ministry of Education Key Laboratory of Micro/Nano Systems for Aerospace, Department of Microsystem Engineering, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an 710072, China
| | - Xiaorui Zhang
- The Ministry of Education Key Laboratory of Micro/Nano Systems for Aerospace, Department of Microsystem Engineering, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an 710072, China
| | - Haoquan Ma
- The Ministry of Education Key Laboratory of Micro/Nano Systems for Aerospace, Department of Microsystem Engineering, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an 710072, China
| | - Mingyang Li
- Industry Engineering Department, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an 710072, China
| | - Honglong Chang
- The Ministry of Education Key Laboratory of Micro/Nano Systems for Aerospace, Department of Microsystem Engineering, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an 710072, China.
| |
Collapse
|
2
|
Cardenas Contreras EM, Tanis E, Lanças FM, Vargas Medina DA. Exploring a reversible adaptation of conventional HPLC for capillary-scale operation. J Chromatogr A 2024; 1730:465021. [PMID: 38897112 DOI: 10.1016/j.chroma.2024.465021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Revised: 05/21/2024] [Accepted: 05/22/2024] [Indexed: 06/21/2024]
Abstract
This study introduces a feasible approach for utilizing a conventional High-Performance Liquid Chromatography (HPLC) instrument at the capillary scale (1 - 10 µL/min). The development of an active flow splitter and an adapted UV-visible (UV-vis) detection cell are described. The system employs an Arduino Uno board to monitor a flow sensor and control a stepper motor that automates a split valve to achieve capillary-scale flow rates from a conventional pump. A capillary UV-vis cell compatible with conventional detectors, featuring an optical path length with a volume of 14 nL, was developed to address the detection challenges at this scale and minimize extra column band broadening. The system performance was assessed by a lab-packed LC capillary column with 0.25 mm x 15 cm dimensions packed with 3.0 µm C18 particles. Model compounds, particularly polycyclic aromatic hydrocarbons (PAHs), were employed to assess the functionality of all developed components in terms of theoretical plates, resolution, and band broadening. The proposed system is a profitable, reliable, and cost-effective tool for miniaturized liquid chromatography.
Collapse
Affiliation(s)
| | - Elton Tanis
- Nano Separations Technologies, São Carlos, Brazil
| | | | | |
Collapse
|
3
|
Warren CG, Dasgupta PK. Liquid phase detection in the miniature scale. Microfluidic and capillary scale measurement and separation systems. A tutorial review. Anal Chim Acta 2024; 1305:342507. [PMID: 38677834 DOI: 10.1016/j.aca.2024.342507] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 03/18/2024] [Accepted: 03/19/2024] [Indexed: 04/29/2024]
Abstract
Microfluidic and capillary devices are increasingly being used in analytical applications while their overall size keeps decreasing. Detection sensitivity for these microdevices gains more importance as device sizes and consequently, sample volumes, decrease. This paper reviews optical, electrochemical, electrical, and mass spectrometric detection methods that are applicable to capillary scale and microfluidic devices, with brief introduction to the principles in each case. Much of this is considered in the context of separations. We do consider theoretical aspects of separations by open tubular liquid chromatography, arguably the most potentially fertile area of separations that has been left fallow largely because of lack of scale-appropriate detection methods. We also examine the theoretical basis of zone electrophoretic separations. Optical detection methods discussed include UV/Vis absorbance, fluorescence, chemiluminescence and refractometry. Amperometry is essentially the only electrochemical detection method used in microsystems. Suppressed conductance and especially contactless conductivity (admittance) detection are in wide use for the detection of ionic analytes. Microfluidic devices, integrated to various mass spectrometers, including ESI-MS, APCI-MS, and MALDI-MS are discussed. We consider the advantages and disadvantages of each detection method and compare the best reported limits of detection in as uniform a format as the available information allows. While this review pays more attention to recent developments, our primary focus has been on the novelty and ingenuity of the approach, regardless of when it was first proposed, as long as it can be potentially relevant to miniature platforms.
Collapse
Affiliation(s)
- Cable G Warren
- Department of Chemistry and Biochemistry, University of Texas at Arlington, Arlington, TX, 76019-0065, United States
| | - Purnendu K Dasgupta
- Department of Chemistry and Biochemistry, University of Texas at Arlington, Arlington, TX, 76019-0065, United States.
| |
Collapse
|
4
|
Amirian H, Dalvand K, Ghiasvand A. Seamless integration of Internet of Things, miniaturization, and environmental chemical surveillance. ENVIRONMENTAL MONITORING AND ASSESSMENT 2024; 196:582. [PMID: 38806872 DOI: 10.1007/s10661-024-12698-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Accepted: 04/30/2024] [Indexed: 05/30/2024]
Abstract
IoT is a game-changer across all fields, including chemistry. Embracing sustainable practices and green chemistry, the miniaturization and automation of systems, and their integration into IoT is key to achieving these principles, as a rising trend with momentum. Particularly, IoT and analytical chemistry are linked in the rapid exchange of analytical data for environmental, industrial, healthcare, and educational applications. Meanwhile, cooperation with other fields of science is evident, and there is a prompt and subjective analysis of information related to analytical systems and methodologies. This paper will review the concepts, requirements, and architecture of IoT and its role in the miniaturization and automation of analytical tools using electronic modules and sensors. The aim is to explore the standards and perspectives of IoT and its interaction with different aspects of analytical chemistry. Additionally, it aimed to explain the basics and applications of IoT for chemists, and its relevance to different subfields of analytical chemistry, particularly in the field of environmental chemical surveillance. The article also covers updating IoT devices and creating DIY-based degradation devices to enhance the educational aspect of chemistry and reduce barriers to lab facilities and equipment. Lastly, it will explore how IoT is really important and how it's going to significantly impact analytical chemistry.
Collapse
Affiliation(s)
- Hamzeh Amirian
- Department of Analytical Chemistry, Faculty of Chemistry, Lorestan University, Khorramabad, Iran
| | - Kolsoum Dalvand
- Department of Analytical Chemistry, Faculty of Chemistry, Lorestan University, Khorramabad, Iran
| | - Alireza Ghiasvand
- Department of Analytical Chemistry, Faculty of Chemistry, Lorestan University, Khorramabad, Iran.
| |
Collapse
|
5
|
Hemida M, Haidar Ahmad IA, Barrientos RC, Regalado EL. Computer-assisted multifactorial method development for the streamlined separation and analysis of multicomponent mixtures in (Bio)pharmaceutical settings. Anal Chim Acta 2024; 1293:342178. [PMID: 38331548 DOI: 10.1016/j.aca.2023.342178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 12/13/2023] [Accepted: 12/23/2023] [Indexed: 02/10/2024]
Abstract
The (bio)pharmaceutical industry is rapidly moving towards complex drug modalities that require a commensurate level of analytical enabling technologies that can be deployed at a fast pace. Unsystematic method development and unnecessary manual intervention remain a major barrier towards a more efficient deployment of meaningful analytical assay across emerging modalities. Digitalization and automation are key to streamline method development and enable rapid assay deployment. This review discusses the use of computer-assisted multifactorial chromatographic method development strategies for fast-paced downstream characterization and purification of biopharmaceuticals. Various chromatographic techniques such as reversed-phase liquid chromatography (RPLC), hydrophilic interaction liquid chromatography (HILIC), ion exchange chromatography (IEX), hydrophobic interaction chromatography (HIC), and supercritical fluid chromatography (SFC) are addressed and critically reviewed. The most significant parameters for retention mechanism modelling, as well as mapping the separation landscape for optimal chromatographic selectivity and resolution are also discussed. Furthermore, several computer-assisted approaches for optimization and development of chromatographic methods of therapeutics, including linear, nonlinear, and multifactorial modelling are outlined. Finally, the potential of the chromatographic modelling and computer-assisted optimization strategies are also illustrated, highlighting substantial productivity improvements, and cost savings while accelerating method development, deployment and transfer processes for therapeutic analysis in industrial settings.
Collapse
Affiliation(s)
- Mohamed Hemida
- Analytical Research and Development, MRL, Merck & Co., Inc., 126 E. Lincoln Avenue, Rahway, NJ, 07065, United States.
| | - Imad A Haidar Ahmad
- Analytical Research and Development, MRL, Merck & Co., Inc., 126 E. Lincoln Avenue, Rahway, NJ, 07065, United States.
| | - Rodell C Barrientos
- Analytical Research and Development, MRL, Merck & Co., Inc., 126 E. Lincoln Avenue, Rahway, NJ, 07065, United States
| | - Erik L Regalado
- Analytical Research and Development, MRL, Merck & Co., Inc., 126 E. Lincoln Avenue, Rahway, NJ, 07065, United States
| |
Collapse
|
6
|
Hicks MB, Mattern K, Fine J, Grosser S, Patel D, Weisel L, Aggarwal P. Portable capillary LC for in-line UV monitoring and MS detection: Comparable sensitivity and much lower solvent consumption. J Sep Sci 2023; 46:e2300300. [PMID: 37715328 DOI: 10.1002/jssc.202300300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2023] [Revised: 08/26/2023] [Accepted: 08/29/2023] [Indexed: 09/17/2023]
Abstract
Pharmaceutical development currently relies on quality separation methods from early discovery through to line-of-site manufacturing. There have been significant advancements made regarding the column particle packing, internal diameter, length connectivity, the understanding of the impact key parameters like void volume, flow rate, and temperature all that affects the resultant separation quality, that is, resolution, peak shape, peak width, run time, and signal-to-noise ratio. There is however a strong need to establish better alternatives to large bulky high-performance liquid chromatography racks either for process analytical reaction monitoring or mass spectrometry analysis in establishing product quality. Compact, portable high-pressure liquid chromatography can be a more efficient alternative to traditional ultra-high pressure liquid chromatography and traditional liquid chromatography. The compact versatile instrument evaluated here allows good separation control with either the on-board column with fixed ultra-violet wavelength cartridge or for use with a high-resolution mass spectrometry. Significant space reduction results in greener lab spaces with improved energy efficiency for smaller labs with lower energy demands. In addition, this compact liquid chromatography was used as a portable reaction monitoring solution to compare forced degradation kinetics and assess portable liquid chromatography-mass spectrometry capability for the analyses required for pharmaceutical drug product testing.
Collapse
Affiliation(s)
- Michael B Hicks
- Analytical Research & Development, MRL, Merck & Co., Inc., Rahway, New Jersey, USA
| | - Keith Mattern
- Process Enabling Technologies, MRL, Merck & Co., Inc., Rahway, New Jersey, USA
| | - Jonathan Fine
- Analytical Research & Development, MRL, Merck & Co., Inc., Rahway, New Jersey, USA
| | - Shane Grosser
- Process Enabling Technologies, MRL, Merck & Co., Inc., Rahway, New Jersey, USA
| | - Daya Patel
- Analytical Research & Development, MRL, Merck & Co., Inc., Rahway, New Jersey, USA
| | - Lauren Weisel
- Analytical Research & Development, MRL, Merck & Co., Inc., Rahway, New Jersey, USA
| | - Pankaj Aggarwal
- Analytical Research & Development, MRL, Merck & Co., Inc., Massachusetts, Boston, USA
| |
Collapse
|
7
|
Mikhail IE, Hemida M, Lebanov L, Astrakhantseva S, Gupta V, Hortin P, Parry JS, Macka M, Paull B. Multi-wavelength deep-ultraviolet absorbance detector based upon program-controlled pulsing light-emitting diodes. J Chromatogr A 2023; 1709:464382. [PMID: 37722175 DOI: 10.1016/j.chroma.2023.464382] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2023] [Revised: 09/11/2023] [Accepted: 09/13/2023] [Indexed: 09/20/2023]
Abstract
A novel approach for multi-wavelength ultraviolet (UV) absorbance detection has been introduced employing a single board computer (SBC) with a field programmable gate array (FPGA), Red Pitaya SBC, to generate separated micro pulses for three deep-ultraviolet light-emitting diodes (DUV-LEDs), λmax = 235, 250, and 280 nm, along with data acquisition and processing via a custom-made program. The pulse set generation and data acquisition were synchronized using the SBC. The outputs of the three pulsing DUV-LEDs were combined and transmitted to the flow cell via a solarisation resistant trifurcated optical fiber (OF). An ultra-fast responding photodiode was connected to the optical-fiber-compatible flow cell to record the intensity of the DUV pulses. Upper limit of detector linearity (A95 %) was found to be 1917 mAU, 2189 mAU, and 1768 mAU at 235 nm, 250 nm, and 280 nm, respectively, with stray light ≤0.9 %. In addition, the effective path length (Leff) was estimated to be ≥98.0 % of the length of the used flow cell (50 mm). The new pulsed multi-LEDs absorbance detector (PMLAD) has been successfully coupled with a standard liquid chromatograph and utilized for the analysis of pharmaceuticals. Paracetamol, caffeine, and aspirin were simultaneously determined at 250, 280, and 235 nm, respectively, using the PMLAD. The absorbance ratios between the different wavelengths were applied to further confirm the identity of the studied compounds. Excellent linearity was achieved over a range of 0.1-3.2 µg/mL for paracetamol, 0.4-6.4 µg/mL for caffeine, and 0.8-12.8 µg/mL for aspirin with a regression correlation coefficient (r2) ≥ 0.99996. The quantitation limits (LOQs) were 0.10 µg/mL, 0.38 µg/mL, and 0.66 µg/mL for paracetamol, caffeine, and aspirin, respectively.
Collapse
Affiliation(s)
- Ibraam E Mikhail
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences (Chemistry), University of Tasmania, Hobart, Tasmania 7001, Australia
| | - Mohamed Hemida
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences (Chemistry), University of Tasmania, Hobart, Tasmania 7001, Australia
| | - Leo Lebanov
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences (Chemistry), University of Tasmania, Hobart, Tasmania 7001, Australia
| | - Snezhana Astrakhantseva
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences (Chemistry), University of Tasmania, Hobart, Tasmania 7001, Australia
| | - Vipul Gupta
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences (Chemistry), University of Tasmania, Hobart, Tasmania 7001, Australia
| | - Philip Hortin
- Central Science Laboratory, University of Tasmania, Private Bag 74, Hobart, Tasmania 7001, Australia
| | - John S Parry
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences (Chemistry), University of Tasmania, Hobart, Tasmania 7001, Australia; Central Science Laboratory, University of Tasmania, Private Bag 74, Hobart, Tasmania 7001, Australia
| | - Mirek Macka
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences (Chemistry), University of Tasmania, Hobart, Tasmania 7001, Australia; Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, CZ-613 00 Brno, Czech Republic; Central European Institute of Technology, Brno University of Technology, Purkynova 123 3058/10, CZ-612 00 Brno, Czech Republic
| | - Brett Paull
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences (Chemistry), University of Tasmania, Hobart, Tasmania 7001, Australia.
| |
Collapse
|
8
|
Medina DAV, Cardoso AT, Borsatto JVB, Lanças FM. Open tubular liquid chromatography: Recent advances and future trends. J Sep Sci 2023; 46:e2300373. [PMID: 37582640 DOI: 10.1002/jssc.202300373] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Revised: 07/28/2023] [Accepted: 07/31/2023] [Indexed: 08/17/2023]
Abstract
Nano-liquid chromatography (nanoLC) is gaining significant attention as a primary analytical technique across various scientific domains. Unlike conventional high-performance LC, nanoLC utilizes columns with inner diameters (i.ds.) usually ranging from 10 to 150 μm and operates at mobile phase flow rates between 10 and 1000 nl/min, offering improved chromatographic performance and detectability. Currently, most exploration of nanoLC has focused on particle-packed columns. Although open tubular LC (OTLC) can provide superior performance, optimized OTLC columns require very narrow i.ds. (< 10 μm) and demand challenging instrumentation. At the moment, these challenges have limited the success of OTLC. Nevertheless, remarkable progress has been made in developing and utilizing OTLC systems featuring narrow columns (< 2 μm). Additionally, significant efforts have been made to explore larger columns (10-75 μm i.d), demonstrating practical applicability in many situations. Due to their perceived advantages, interest in OTLC has resurged in the last two decades. This review provides an updated outlook on the latest developments in OTLC, focusing on instrumental challenges, achievements, and advancements in column technology. Moreover, it outlines selected applications that illustrate the potential of OTLC for performing targeted and untargeted studies.
Collapse
Affiliation(s)
- Deyber Arley Vargas Medina
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, São Paulo, Brazil
| | - Alessandra Timoteo Cardoso
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, São Paulo, Brazil
| | - João Victor Basolli Borsatto
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, São Paulo, Brazil
| | - Fernando Mauro Lanças
- Departamento de Química e Física Molecular, São Carlos Institute of Chemistry, University of São Paulo, São Carlos, São Paulo, Brazil
| |
Collapse
|
9
|
Rodríguez-Palma CE, Herráez-Hernández R, Campíns-Falcó P. A modified micro-solid phase extraction device for in-port elution and injection into portable liquid chromatography: A proof-of-concept study. J Chromatogr A 2023; 1705:464216. [PMID: 37480726 DOI: 10.1016/j.chroma.2023.464216] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Revised: 07/11/2023] [Accepted: 07/13/2023] [Indexed: 07/24/2023]
Abstract
A micro-solid phase extraction (micro-SPE) device packed with a C18 sorbent (10 mg) has been developed for the enrichment and purification of organic water pollutants prior to their analysis using a portable liquid chromatograph with a dual UV detector. To this end, the sorbent was immobilized at the inlet of a 4 mm syringe filter (0.20 µm), which was modified to reduce its internal volume. The filter was coupled to the needle of the chromatograph. After loading the sample and cleaning the sorbent for analyte purification, the device was installed into the injection port of the chromatograph, and the target compounds were desorbed and transferred directly to the chromatographic column with a small volume of organic solvent. Under optimized conditions, sample volumes as large as 50 mL could be processed with the micro-SPE device, while the analytes were desorbed with only 60 µL of methanol. As a result, efficient preconcentration could be reached, as demonstrated for different water contaminants, namely aclonifen, bifenox, tritosulfuron, triflusulfuron-methyl and caffeine. The proposed micro-SPE device was applied to the analysis of different types of water (river, well, sea, ditch and wastewater). The recoveries of the target compounds in samples ranged from 76 % to 109 %, which allowed their detection at low to sub µg/L levels. All operations were carried out manually, and thus, no additional laboratory instruments such as centrifuges, stirrers or evaporators were required. This proof-of-concept study shows that the proposed micro-SPE approach can be considered a reliable and effective option for the on-site analysis of pollutants in environmental water samples by portable liquid chromatography.
Collapse
Affiliation(s)
- C E Rodríguez-Palma
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química. Universitat de València. Dr. Moliner 50, 46100-Burjassot, València, Spain
| | - R Herráez-Hernández
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química. Universitat de València. Dr. Moliner 50, 46100-Burjassot, València, Spain.
| | - P Campíns-Falcó
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química. Universitat de València. Dr. Moliner 50, 46100-Burjassot, València, Spain
| |
Collapse
|
10
|
Chen L, Ghiasvand A, Paull B. Applications of thread-based microfluidics: Approaches and options for detection. Trends Analyt Chem 2023. [DOI: 10.1016/j.trac.2023.117001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/02/2023]
|
11
|
Long path gas-phase absorption detector using a 235 nm deep-UV LED source for the determination of nitrite, nitrate and total dissolved nitrogen in waters. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2023. [DOI: 10.1016/j.cjac.2022.100205] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
12
|
Mai Y, Debruille K, Edwards S, Cahoon S, Ghiasvand A, Murray E, Paull B. Portable and Field-Deployable Liquid Chromatography for Environmental Studies. LCGC EUROPE 2022. [DOI: 10.56530/lcgc.eu.ux5882h7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
Abstract
In this extended special feature to celebrate the 35th anniversary edition of LCGC Europe, leading figures from the separation science community explore contemporary trends in separation science and identify possible future developments.
Collapse
|
13
|
Kaljurand M, Mazina-Šinkar J. Portable capillary electrophoresis as a green analytical technology. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116811] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
14
|
Câmara JS, Martins C, Pereira JAM, Perestrelo R, Rocha SM. Chromatographic-Based Platforms as New Avenues for Scientific Progress and Sustainability. Molecules 2022; 27:5267. [PMID: 36014506 PMCID: PMC9412595 DOI: 10.3390/molecules27165267] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 07/29/2022] [Accepted: 08/15/2022] [Indexed: 11/29/2022] Open
Abstract
Chromatography was born approximately one century ago and has undergone outstanding technological improvements in innovation, research, and development since then that has made it fundamental to advances in knowledge at different levels, with a relevant impact on the well-being and health of individuals. Chromatography boosted a comprehensive and deeper understanding of the complexity and diversity of human-environment interactions and systems, how these interactions affect our life, and the several societal challenges we are currently facing, namely those related to the sustainability of our planet and the future generations. From the life sciences, which allowed us to identify endogenous metabolites relevant to disease mechanisms, to the OMICS field, nanotechnology, clinical and forensic analysis, drug discovery, environment, and "foodprint", among others, the wide range of applications of today's chromatographic techniques is impressive. This is fueled by a great variability of powerful chromatographic instruments currently available, with very high sensitivity, resolution, and identification capacity, that provide a strong basis for an analytical platform able to support the challenging demands of the postgenomic and post COVID-19 eras. Within this context, this review aims to address the great utility of chromatography in helping to cope with several societal-based challenges, such as the characterization of disease and/or physiological status, and the response to current agri-food industry challenges of food safety and sustainability, or the monitoring of environmental contamination. These are increasingly important challenges considering the climate changes, the tons of food waste produced every day, and the exponential growth of the human population. In this context, the principles governing the separation mechanisms in chromatography as well the different types and chromatographic techniques will be described. In addition, the major achievements and the most important technological advances will be also highlighted. Finally, a set of studies was selected in order to evince the importance of different chromatographic analyses to understand processes or create fundamental information in the response to current societal challenges.
Collapse
Affiliation(s)
- José S. Câmara
- CQM-Centro de Química da Madeira, Universidade da Madeira, Campus da Penteada, 9020-105 Funchal, Portugal
- Departamento de Química, Faculdade de Ciências Exatas e Engenharia, Universidade da Madeira, Campus da Penteada, 9020-105 Funchal, Portugal
| | - Cátia Martins
- Departamento de Química & LAQV-REQUIMTE, Universidade de Aveiro, Campus Universitário Santiago, 3810-193 Aveiro, Portugal
| | - Jorge A. M. Pereira
- CQM-Centro de Química da Madeira, Universidade da Madeira, Campus da Penteada, 9020-105 Funchal, Portugal
| | - Rosa Perestrelo
- CQM-Centro de Química da Madeira, Universidade da Madeira, Campus da Penteada, 9020-105 Funchal, Portugal
| | - Sílvia M. Rocha
- Departamento de Química & LAQV-REQUIMTE, Universidade de Aveiro, Campus Universitário Santiago, 3810-193 Aveiro, Portugal
| |
Collapse
|
15
|
Peak broadening caused by using different micro-liquid chromatography detectors. Anal Bioanal Chem 2022; 414:6107-6114. [PMID: 35705858 DOI: 10.1007/s00216-022-04170-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Revised: 06/01/2022] [Accepted: 06/07/2022] [Indexed: 11/01/2022]
Abstract
Advancements in column technology resulted in smaller particles and more efficient phases. In parallel, the use of columns with reduced dimensions is becoming more common. This means the effective column volume is also decreased, thereby making the systems more susceptible to effects of band broadening due to extra-column volume. Despite these trends and the fact that a growing number of miniaturized liquid chromatography systems are being offered commercially, manufacturers often stick to the modular concept with dedicated units for pumps, column oven, and detectors. This modular design results in long connection capillaries, which leads to extra-column band broadening and consequently prevents the exploitation of the intrinsic efficiency of state-of-the-art columns. In particular, band broadening post column has a considerable negative effect on efficiency. In this study, mass flow and concentration-dependent detectors were examined for their influence on band broadening using a micro-LC system. A mass spectrometric detector, an evaporative light scattering detector, two UV detectors, and a previously undescribed fluorescence detector were compared. The influence on efficiency is compared using plate height vs linear velocity data and peak variance. It is shown that an increase in the inner diameter after the post-column transfer capillary leads to significant loss in plate height. Comparing the UV detectors, it could be shown that the dispersion was reduced by 38% by the reduction of the post-column volume. The largest variance was found for the evaporative light scattering detector, which was 368% higher compared to the variance of the detector with the least effect on band broadening.
Collapse
|
16
|
Foster SW, Xie X, Hellmig JM, Moura‐Letts G, West WR, Lee ML, Grinias JP. Online monitoring of small volume reactions using compact liquid chromatography instrumentation. SEPARATION SCIENCE PLUS 2022; 5:213-219. [PMID: 37008988 PMCID: PMC10065474 DOI: 10.1002/sscp.202200012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
A wide variety of analytical techniques have been employed for monitoring chemical reactions, with online instrumentation providing additional benefits compared to offline analysis. A challenge in the past for online monitoring has been placement of the monitoring instrumentation as close as possible to the reaction vessel to maximize sampling temporal resolution and preserve sample composition integrity. Furthermore, the ability to sample very small volumes from bench-scale reactions allows the use of small reaction vessels and conservation of expensive reagents. In this study, a compact capillary LC instrument was used for online monitoring of as small as 1 mL total volume of a chemical reaction mixture, with automated sampling of nL-scale volumes directly from the reaction vessel used for analysis. Analyses to demonstrate short term (~2 h) and long term (~ 50 h) reactions were conducted using tandem on-capillary ultraviolet absorbance followed by in-line MS detection or ultraviolet absorbance detection alone, respectively. For both short term and long term reactions (10 and 250 injections, respectively), sampling approaches using syringe pumps minimized the overall sample loss to ~0.2% of the total reaction volume.
Collapse
Affiliation(s)
- Samuel W. Foster
- Department of Chemistry & Biochemistry Rowan University Glassboro New Jersey USA
| | - Xiaofeng Xie
- Axcend LLC Provo Utah USA
- Department of Chemistry and Biochemistry Brigham Young University Provo Utah USA
| | - Jacob M. Hellmig
- Department of Chemistry & Biochemistry Rowan University Glassboro New Jersey USA
| | - Gustavo Moura‐Letts
- Department of Chemistry & Biochemistry Rowan University Glassboro New Jersey USA
| | | | - Milton L. Lee
- Axcend LLC Provo Utah USA
- Department of Chemistry and Biochemistry Brigham Young University Provo Utah USA
| | - James P. Grinias
- Department of Chemistry & Biochemistry Rowan University Glassboro New Jersey USA
| |
Collapse
|
17
|
Towards in field miniaturized liquid chromatography: biocides in wastewater as a proof of concept. J Chromatogr A 2022; 1673:463119. [DOI: 10.1016/j.chroma.2022.463119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2022] [Revised: 04/22/2022] [Accepted: 05/02/2022] [Indexed: 11/18/2022]
|
18
|
Ferguson P, Hicks M. The state-of-the-art and future perspectives for SFC. SEP SCI TECHNOL 2022. [DOI: 10.1016/b978-0-323-88487-7.00013-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
|
19
|
Patel SV, Lurie IS. The use of portable separation devices for forensic analysis: A review of recent literature. Forensic Chem 2021. [DOI: 10.1016/j.forc.2021.100365] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
|
20
|
Hemida M, Haddad PR, Lam SC, Coates LJ, Riley F, Diaz A, Gooley AA, Wirth HJ, Guinness S, Sekulic S, Paull B. Small footprint liquid chromatography-mass spectrometry for pharmaceutical reaction monitoring and automated process analysis. J Chromatogr A 2021; 1656:462545. [PMID: 34543882 DOI: 10.1016/j.chroma.2021.462545] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Revised: 09/03/2021] [Accepted: 09/04/2021] [Indexed: 12/30/2022]
Abstract
Liquid chromatography (LC) has broad applicability in the pharmaceutical industry, from the early stages of drug discovery to reaction monitoring and process control. However, small footprint, truly portable LC systems have not yet been demonstrated and fully evaluated practically for on-line, in-line or at-line pharmaceutical analysis. Herein, a portable, briefcase-sized capillary LC fitted with a miniature multi-deep UV-LED detector has been developed and interfaced with a portable mass spectrometer for on-site pharmaceutical analysis. With this configuration, the combined small footprint portable LC-UV/MS system was utilized for the determination of small molecule pharmaceuticals and reaction monitoring. The LC-UV/MS system was interfaced directly with a process sample cart and applied to automated pharmaceutical analysis, as well as also being benchmarked against a commercial process UPLC system (Waters PATROL system). The portable system gave low detection limits (∼3 ppb), a wide dynamic range (up to 200 ppm) and was used to confirm the identity of reaction impurities and for studying the kinetics of synthesis. The developed platform showed robust performance for automated process analysis, with less than 5.0% relative standard deviation (RSD) on sample-to-sample reproducibility, and less than 2% carryover between samples. The system has been shown to significantly increase throughput by providing near real-time analysis and to improve understanding of synthetic processes.
Collapse
Affiliation(s)
- Mohamed Hemida
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia; Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia
| | - Paul R Haddad
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia; Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia
| | - Shing C Lam
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia; Trajan Scientific and Medical, 7 Argent Place, Ringwood, Victoria 3134, Australia
| | - Lewellwyn J Coates
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia; Trajan Scientific and Medical, 7 Argent Place, Ringwood, Victoria 3134, Australia
| | - Frank Riley
- Pfizer Worldwide Research and Development, Eastern Point Road, Groton, Connecticut, 06340, United States
| | - Angel Diaz
- Pfizer Worldwide Research and Development, Eastern Point Road, Groton, Connecticut, 06340, United States
| | - Andrew A Gooley
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia; Trajan Scientific and Medical, 7 Argent Place, Ringwood, Victoria 3134, Australia
| | - Hans-Jürgen Wirth
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia; Trajan Scientific and Medical, 7 Argent Place, Ringwood, Victoria 3134, Australia
| | - Steven Guinness
- Pfizer Worldwide Research and Development, Eastern Point Road, Groton, Connecticut, 06340, United States
| | - Sonja Sekulic
- Pfizer Worldwide Research and Development, Eastern Point Road, Groton, Connecticut, 06340, United States
| | - Brett Paull
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia; Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia.
| |
Collapse
|
21
|
Hemida M, Ghiasvand A, Gupta V, Coates LJ, Gooley AA, Wirth HJ, Haddad PR, Paull B. Small-Footprint, Field-Deployable LC/MS System for On-Site Analysis of Per- and Polyfluoroalkyl Substances in Soil. Anal Chem 2021; 93:12032-12040. [PMID: 34436859 DOI: 10.1021/acs.analchem.1c02193] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Per- and polyfluoroalkyl substances (PFASs) are emerging environmental pollutants of global concern. For rapid field site evaluation, there are very few sensitive, field-deployable analytical techniques. In this work, a portable lightweight capillary liquid chromatography (capLC) system was coupled with a small footprint portable mass spectrometer and configured for field-based applications. Further, an at-site ultrasound-assisted extraction (pUAE) methodology was developed and applied with a portable capLC/mass spectrometry (MS) system for on-site analysis of PFASs in real soil samples. The influential variables on the integration of capLC with MS and on the resolution and signal intensity of the capLC/MS setup were investigated. The important parameters affecting the efficiency of the pUAE method were also studied and optimized using the response surface methodology based on a central composite design. The mean recovery for 11 PFASs ranged between 70 and 110%, with relative standard deviations ranging from 3 to 12%. In-field method sensitivity for 12 PFASs ranged from 0.6 to 0.1 ng/g, with wide dynamic ranges (1-600 ng/g) and excellent linearities (R2 > 0.991). The in-field portable system was benchmarked against a commercial lab-based LC-tandem MS (MS/MS) system for the analysis of PFASs in real soil samples, with the results showing good agreement. When deployed to a field site, 12 PFASs were detected and identified in real soil samples at concentrations ranging from 8.1 ng/g (for perfluorooctanesulfonic acid) to 2935.0 ng/g (perfluorohexanesulfonic acid).
Collapse
Affiliation(s)
- Mohamed Hemida
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia.,Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia
| | - Alireza Ghiasvand
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia.,ARC Centre of Excellence for Electromaterials Science (ACES), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia
| | - Vipul Gupta
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia.,ARC Centre of Excellence for Electromaterials Science (ACES), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia
| | - Lewellwyn J Coates
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia.,Trajan Scientific and Medical, 7 Argent Place, Ringwood, Victoria 3134, Australia
| | - Andrew A Gooley
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia.,Trajan Scientific and Medical, 7 Argent Place, Ringwood, Victoria 3134, Australia
| | - Hans-Jürgen Wirth
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia.,Trajan Scientific and Medical, 7 Argent Place, Ringwood, Victoria 3134, Australia
| | - Paul R Haddad
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia.,Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia
| | - Brett Paull
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia.,Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia.,ARC Centre of Excellence for Electromaterials Science (ACES), School of Natural Sciences, University of Tasmania, Hobart, Tasmania 7001, Australia
| |
Collapse
|
22
|
Davis JJ, Foster SW, Grinias JP. Low-cost and open-source strategies for chemical separations. J Chromatogr A 2021; 1638:461820. [PMID: 33453654 PMCID: PMC7870555 DOI: 10.1016/j.chroma.2020.461820] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 12/12/2020] [Accepted: 12/14/2020] [Indexed: 12/18/2022]
Abstract
In recent years, a trend toward utilizing open access resources for laboratory research has begun. Open-source design strategies for scientific hardware rely upon the use of widely available parts, especially those that can be directly printed using additive manufacturing techniques and electronic components that can be connected to low-cost microcontrollers. Open-source software eliminates the need for expensive commercial licenses and provides the opportunity to design programs for specific needs. In this review, the impact of the "open-source movement" within the field of chemical separations is described, primarily through a comprehensive look at research in this area over the past five years. Topics that are covered include general laboratory equipment, sample preparation techniques, separations-based analysis, detection strategies, electronic system control, and software for data processing. Remaining hurdles and possible opportunities for further adoption of open-source approaches in the context of these separations-related topics are also discussed.
Collapse
Affiliation(s)
- Joshua J Davis
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, NJ 08028, United States
| | - Samuel W Foster
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, NJ 08028, United States
| | - James P Grinias
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, NJ 08028, United States.
| |
Collapse
|
23
|
Lankelma J, van Iperen DJ, van der Sluis PJ. Towards using high-performance liquid chromatography at home. J Chromatogr A 2021; 1639:461925. [PMID: 33556779 DOI: 10.1016/j.chroma.2021.461925] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Revised: 01/13/2021] [Accepted: 01/16/2021] [Indexed: 12/26/2022]
Abstract
In order to make high-performance liquid chromatography (HPLC) more widely available at home and in small-scale settings, we have simplified two of its most costly modules, namely the pump and the detector. This should make the setup affordable for home or small laboratory use. A manual HPLC pump was constructed so as to fit into a caulk gun from a local hardware store enabling the generation of 100-150 bar of pressure. In order to limit the pressure drop during the running of a chromatogram, a pulse dampener was developed. We further modified the electrochemical detection (ECD) system so as to use a cheap boron-doped diamond electrode with an overlay of thin filter paper, causing an eluent flow over the electrode by wicking and gravity. Both the pump and the detector are at least ten times cheaper than conventional HPLC modules. Using a home-packed JupiterⓇ Proteo reversed phase capillary column we show how this low-cost HPLC system generates well resolving chromatograms after direct injection of fresh urine. The ECD did not lose its sensitivity during regular use over more than half a year. For homovanillic acid (HVA), which is of medical interest, we measured a linear dynamic range of two orders of magnitude, a detection limit of HVA in the injected sample of 3 μM and a coefficient of variation <10%. The contribution to peak broadening by the detector was much smaller than the contributions by the injector and by the column. After consumption of table olives containing hydroxytyrosol (HT), its metabolite HVA in the corresponding urine could be measured quantitatively. An approach to quantify HT in table olives is presented, as well. This method provides a new tool for investigating physiology of oneself or of dear ones at home.
Collapse
Affiliation(s)
- Jan Lankelma
- Department of Molecular Cell Physiology, VU University Amsterdam, O
- 2 Lab Building, De Boelelaan 1108, 1081 HZ Amsterdam, The Netherlands; Foundation for Chromatography at home, Demonstrator Lab, Amsterdam, The Netherlands.
| | - Dirck J van Iperen
- Department of Fine mechanics and Engineering VU - Bèta, VU University Amsterdam, The Netherlands
| | - Paul J van der Sluis
- Foundation for Chromatography at home, Demonstrator Lab, Amsterdam, The Netherlands
| |
Collapse
|
24
|
A new quantitative gel electrophoresis method with image-based detection for the determination of food dyes and metallic ions. Talanta 2021; 221:121602. [PMID: 33076133 DOI: 10.1016/j.talanta.2020.121602] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 08/26/2020] [Accepted: 08/27/2020] [Indexed: 01/25/2023]
Abstract
This work describes an alternative application of gel electrophoresis for the separation and quantification of analytes with low molecular weights using an innovative and low-cost apparatus that enables the acquisition of image-based electropherograms with a webcam. As a proof of concept, the determination of Cu and Ni content in metallic alloys was evaluated by means of the separation and detection of the metallic ions, previously complexed with Eriochrome Black T. Furthermore, the determination of the food colouring agents Sunset Yellow FCF, Tartrazine, Brilliant Blue FCF and Amaranth Red in powder refreshment samples was investigated as alternative to well-stablished methods used for this purpose. For all investigated analytes, the corresponding electrophoretic peaks showed signal to noise ratios ranging from 10 to 180, suitable precision on areas (RSD < 3.5%) and linear relationships (R > 0.99) between RGB detected signals and concentrations of the standard solutions. Application of the method to the determination of Cu and Ni contents in metallic alloys provided results with no significant differences, at 95% confidence level, when compared to the results obtained with a FAAS based method. Apparent recoveries estimated for powder refreshment samples fortified with the food dyes ranged from 93% to 108% for added and found contents, suggesting the absence of matrix effects. The studies prove the feasibility of separation and quantification of coloured analytes by gel electrophoresis and image-based detection that can be useful for different samples.
Collapse
|
25
|
Ponce-Rodríguez HD, Verdú-Andrés J, Herráez-Hernández R, Campíns-Falcó P. Exploring hand-portable nano-liquid chromatography for in place water analysis: Determination of trimethylxanthines as a use case. THE SCIENCE OF THE TOTAL ENVIRONMENT 2020; 747:140966. [PMID: 32768766 DOI: 10.1016/j.scitotenv.2020.140966] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/08/2020] [Revised: 07/12/2020] [Accepted: 07/12/2020] [Indexed: 06/11/2023]
Abstract
Analytical performance and optimization of figures of merit of a portable nano liquid chromatograph (NanoLC) with UV detection at 255 nm have been established for in place analysis. Methylxanthines: caffeine, theophylline and theobromine were selected as target analytes. A fast lab method based on IT-SPME coupled on line with capillary liquid chromatograph (CapLC) with diode array detection (DAD) was employed for comparative studies. IT-SPME and solid phase extraction were coupled off-line to NanoLC for improving instrumental parameters, mainly detection capacity and selectivity. IT-SPME or SPE/portable NanoLC based methods were superior in terms of chromatographic resolution and organic solvent consumption per sample, around 200 μL vs 10 mL for IT-SPME-CapLC-DAD. Limits of detection (LODs) obtained with the SPE/portable NanoLC were 2-10 ng/mL, which can be suitable for testing the presence of the analytes in several environmental waters in the field. As predictable, the lab method provided better LODs, between 0.1 and 0.5 ng/mL. Good linearity was achieved for both methods and precision was similar for them (≤7%). Both systems were tested for the analysis of real water samples with suitable results.
Collapse
Affiliation(s)
- H D Ponce-Rodríguez
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, Burjassot, 46100 València, Spain; Departamento de Control Químico, Facultad de Química y Farmacia, Universidad Nacional Autónoma de Honduras, Ciudad Universitaria, Tegucigalpa, Honduras
| | - J Verdú-Andrés
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, Burjassot, 46100 València, Spain
| | - R Herráez-Hernández
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, Burjassot, 46100 València, Spain.
| | - P Campíns-Falcó
- MINTOTA Research Group, Departament de Química Analítica, Facultat de Química, Universitat de València, Dr. Moliner 50, Burjassot, 46100 València, Spain.
| |
Collapse
|
26
|
Hemida M, Coates LJ, Lam S, Gupta V, Macka M, Wirth HJ, Gooley AA, Haddad PR, Paull B. Miniature Multiwavelength Deep UV-LED-Based Absorption Detection System for Capillary LC. Anal Chem 2020; 92:13688-13693. [PMID: 32985176 DOI: 10.1021/acs.analchem.0c03460] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
A new miniature deep UV absorbance detector has been developed using low-cost and high-performance LEDs, which can be operated in both scanning (230 to 300 nm) and individual wavelength (240, 255, and 275 nm) detection modes. The detector is mostly composed of off-the-shelf components, such as LEDs, trifurcated fiber optic assembly, a capillary Z-type flow cell, and photodiodes. It has been characterized for use with a standard capillary LC system and was benchmarked against a standard variable wavelength capillary LC detector. The detector shows very low levels of stray light (<0.4%), utilization of up to 99.0% of the effective path length of the flow cell, a wide dynamic range (0.5 to 200 μg/mL for sulfamethazine, carbamazepine, and flavone), and low noise levels (at 300 μAU level). The detector was applied within a miniaturized LC system.
Collapse
Affiliation(s)
- Mohamed Hemida
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia.,Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia
| | - Lewellwyn Joseph Coates
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia.,Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia.,Trajan Scientific and Medical, 7 Argent Place, Ringwood, Victoria 3134, Australia
| | - Shing Lam
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia.,Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia
| | - Vipul Gupta
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia.,ARC Centre of Excellence for Electromaterials Science (ACES), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia
| | - Mirek Macka
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia
| | - Hans-Jürgen Wirth
- Trajan Scientific and Medical, 7 Argent Place, Ringwood, Victoria 3134, Australia
| | - Andrew A Gooley
- Trajan Scientific and Medical, 7 Argent Place, Ringwood, Victoria 3134, Australia
| | - Paul R Haddad
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia.,Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia
| | - Brett Paull
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia.,Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia.,ARC Centre of Excellence for Electromaterials Science (ACES), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia
| |
Collapse
|
27
|
Miniaturization of liquid chromatography coupled to mass spectrometry. 3. Achievements on chip-based LC–MS devices. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.116003] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
28
|
Ultraviolet absorbance detector based on a high output power 235 nm surface mounted device-type light-emitting diode. J Chromatogr A 2020; 1631:461540. [PMID: 32980801 DOI: 10.1016/j.chroma.2020.461540] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2020] [Revised: 09/10/2020] [Accepted: 09/13/2020] [Indexed: 12/12/2022]
Abstract
A new miniaturised capillary flow-through deep-UV absorbance detector has been developed using a microscale surface mounted device- type light-emitting diode (LED) (Crystal IS OPTAN 3535-series), emitting at 235 nm and with a half-height band width of 12 nm, and a high-sensitivity Z-shaped flow-cell. Compared with a previously reported TO-39 ball lens LEDs emitting at 235 nm, the new generation LED produced a 20-fold higher optical output and delivered up to 35 times increase in external quantum efficiency (EQE). The Z-cell was based on a reflective rectangular optical path with cross-sectional dimensions of 100 × 100 µm and a physical optical pathlength of 1.2 mm. Inclusion of UV transparent fused-silica ball lenses, between the SMD and the Z-cell, improved light transmission by a factor of 9 and improved the detector signal-to-noise ratio by a factor of 2.2, at the same input current. The detector was housed within an Al-housing fitted with a cooling fan and demonstrated excellent linearity with stray light down to 0.06%, and an effective pathlength of 1.1 mm (92% of nominal pathlength). The resultant detector was fitted successfully into a briefcase-sized portable capillary HPLC system, and practically demonstrated with the detection of a mixture of 13 test compounds at the sub-mg L-1 level in <5 min using gradient elution.
Collapse
|
29
|
Abstract
AbstractThere is a growing need for chemical analyses to be performed in the field, at the point of need. Tools and techniques often found in analytical chemistry laboratories are necessary in performing these analyses, yet have, historically, been unable to do so owing to their size, cost and complexity. Technical advances in miniaturisation and liquid chromatography are enabling the translation of these techniques out of the laboratory, and into the field. Here we examine the advances that are enabling portable liquid chromatography (LC). We explore the evolution of portable instrumentation from its inception to the most recent advances, highlighting the trends in the field and discussing the necessary criteria for developing in-field solutions. While instrumentation is becoming more capable it has yet to find adoption outside of research.
Collapse
|
30
|
Aydoğan C, Rigano F, Krčmová LK, Chung DS, Macka M, Mondello L. Miniaturized LC in Molecular Omics. Anal Chem 2020; 92:11485-11497. [DOI: 10.1021/acs.analchem.0c01436] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Cemil Aydoğan
- Biochemistry Division, Department of Chemistry, Bingöl University, Bingöl 12000,Turkey
- Department of Food Engineering, Bingöl University, Bingöl 12000,Turkey
| | - Francesca Rigano
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Messina I-98168, Italy
| | - Lenka Kujovská Krčmová
- Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Akademika Heyrovského 1203, Hradec Králové 500 05, Czech Republic
- Department of Clinical Biochemistry and Diagnostics, University Hospital, Sokolská 581, Hradec Králové 500 05, Czech Republic
| | - Doo Soo Chung
- Department of Chemistry, Seoul National University, Seoul 08826, Korea
| | - Mirek Macka
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, CZ-613 00 Brno, Czech Republic
- Central European Institute of Technology, Brno University of Technology, Technicka 3058/10, CZ-616 00Brno, Czech Republic
- School of Natural Sciences and Australian Centre for Research on Separation Science (ACROSS), University of Tasmania, Private Bag 75, Hobart 7001, Australia
| | - Luigi Mondello
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Messina I-98168, Italy
- Chromaleont s.r.l., c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Messina I-98168, Italy
- Department of Sciences and Technologies for Human and Environment, University Campus Bio-Medico of Rome, Rome I-00128, Italy
- BeSep s.r.l., c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Messina I-98168, Italy
| |
Collapse
|
31
|
Vargas Medina DA, Maciel EVS, de Toffoli AL, Lanças FM. Miniaturization of liquid chromatography coupled to mass spectrometry. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.115910] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
32
|
Coates LJ, Lam SC, Gooley AA, Haddad PR, Paull B, Wirth HJ. Modular, cost-effective, and portable capillary gradient liquid chromatography system for on-site analysis. J Chromatogr A 2020; 1626:461374. [PMID: 32797852 DOI: 10.1016/j.chroma.2020.461374] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Revised: 06/10/2020] [Accepted: 06/27/2020] [Indexed: 02/08/2023]
Abstract
This work demonstrates the development of a compact, modular, cost-effective separation system configured to address a specific separation problem. The principles of the separation are based on gradient capillary liquid chromatography where the system consists of precision stepper motor-driven portable syringe pumps with interchangeable glass syringes (100 µL to 1000 µL). Excellent flow-rate precision of < 1% RSD was achieved with typical flow-rates ranging from 1 µL/min to 100 µL/min, which was ideal for capillary columns. A variable external loop volume and electrically actuated miniature injection valve was used for sample introduction. Detection was based upon a commercial Z-type UV absorbance flow-cell housed within a custom-built cooling enclosure (40 mm x 40 mm) which also contained a UV-LED light-source and a photodiode. System and chromatographic performance was evaluated using linear gradient elution, with day to day repeatability of <1.5% RSD (n = 6) for peak area, and < 0.4% RSD (n = 6) for retention time, for the separation of a 5 component mixture using a 50 mm X 530 µm ID C18 3 µm particle capillary column. The system can run any commercial or in-house packed columns from 50 mm to 100 mm length with IDs ranging from 200 to 700 µm. The developed portable system was operated using custom-built windows-based chromatography software, complete with data acquisition and system control.
Collapse
Affiliation(s)
- Lewellwyn J Coates
- ARC Centre for Portable Analytical Technologies (ASTech), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart 7000, Tasmania, Australia; Trajan Scientific and Medical, 7 Argent Place, Ringwood, Victoria 3134, Australia
| | - Shing C Lam
- ARC Centre for Portable Analytical Technologies (ASTech), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart 7000, Tasmania, Australia; Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart 7000, Tasmania, Australia
| | - Andrew A Gooley
- ARC Centre for Portable Analytical Technologies (ASTech), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart 7000, Tasmania, Australia; Trajan Scientific and Medical, 7 Argent Place, Ringwood, Victoria 3134, Australia
| | - Paul R Haddad
- ARC Centre for Portable Analytical Technologies (ASTech), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart 7000, Tasmania, Australia; Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart 7000, Tasmania, Australia
| | - Brett Paull
- ARC Centre for Portable Analytical Technologies (ASTech), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart 7000, Tasmania, Australia; Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart 7000, Tasmania, Australia
| | - Hans-Jürgen Wirth
- ARC Centre for Portable Analytical Technologies (ASTech), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart 7000, Tasmania, Australia; Trajan Scientific and Medical, 7 Argent Place, Ringwood, Victoria 3134, Australia.
| |
Collapse
|
33
|
Foster SW, Xie X, Pham M, Peaden PA, Patil LM, Tolley LT, Farnsworth PB, Tolley HD, Lee ML, Grinias JP. Portable capillary liquid chromatography for pharmaceutical and illicit drug analysis. J Sep Sci 2020; 43:1623-1627. [PMID: 31960568 DOI: 10.1002/jssc.201901276] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2019] [Revised: 01/15/2020] [Accepted: 01/16/2020] [Indexed: 12/12/2022]
Abstract
A newly developed portable capillary liquid chromatograph was investigated for the separation of various pharmaceutical and illicit drug compounds. The system consists of two high-pressure syringe pumps capable of delivering capillary-scale flow rates at pressures up to 10 000 psi. Capillary liquid chromatography columns packed with sub-2 μm particles are housed in cartridges that can be inserted into the system and easily connected through high-pressure fluidic contact points by simply applying a specific, predetermined torque rather than using standard fittings and less precise sealing protocols. Several over-the-counter analgesic drug separations are demonstrated, along with a simple online measurement of tablet dissolution. Twenty illicit drug compounds were also separated across six targeted drug panels. The results described in this study demonstrate the capability of this compact liquid chromatography instrument to address several important drug-related applications while simplifying system operation, and greatly reducing solvent usage and waste generation essential for onsite analysis.
Collapse
Affiliation(s)
- Samuel W Foster
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, NJ
| | | | - Michelle Pham
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, NJ
| | | | - Leena M Patil
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT
| | | | - Paul B Farnsworth
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT
| | - H Dennis Tolley
- Department of Statistics, Brigham Young University, Provo, UT
| | - Milton L Lee
- Axcend Corporation, Provo, UT.,Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT
| | - James P Grinias
- Department of Chemistry & Biochemistry, Rowan University, Glassboro, NJ
| |
Collapse
|