1
|
Schöneich S, Cain CN, Sudol PE, Synovec RE. Enabling cuboid-based fisher ratio analysis using total-transfer comprehensive three-dimensional gas chromatography with time-of-flight mass spectrometry. J Chromatogr A 2023; 1708:464341. [PMID: 37660566 DOI: 10.1016/j.chroma.2023.464341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Revised: 08/24/2023] [Accepted: 08/28/2023] [Indexed: 09/05/2023]
Abstract
Comprehensive three-dimensional (3D) gas chromatography with time-of-flight mass spectrometry (GC3-TOFMS) is a promising instrumental platform for the separation of volatiles and semi-volatiles due to its increased peak capacity and selectivity relative to comprehensive two-dimensional gas chromatography with TOFMS (GC×GC-TOFMS). Given the recent advances in GC3-TOFMS instrumentation, new data analysis methods are now required to analyze its complex data structure efficiently and effectively. This report highlights the development of a cuboid-based Fisher ratio (F-ratio) analysis for supervised, non-targeted studies. This approach builds upon the previously reported tile-based F-ratio software for GC×GC-TOFMS data. Cuboid-based F-ratio analysis is enabled by constructing 3D cuboids within the GC3-TOFMS chromatogram and calculating F-ratios for every cuboid on a per-mass channel basis. This methodology is evaluated using a GC3-TOFMS data set of jet fuel spiked with both non-native and native components. The neat and spiked jet fuels were collected on a total-transfer (100 % duty cycle) GC3-TOFMS instrument, employing thermal modulation between the first (1D) and second dimension (2D) columns and dynamic pressure gradient modulation between the 2D and third dimension (3D) columns. In total, cuboid-based F-ratio analysis discovered 32 spiked analytes in the top 50 hits at concentration ratios as low as 1.1. In contrast, tile-based F-ratio analysis of the corresponding GC×GC-TOFMS data only discovered 28 of the spiked analytes total, with only 25 of them in the top 50 hits. Along with discovering more analytes, cuboid-based F-ratio analysis of GC3-TOFMS data resulted in fewer false positives. The increased discoverability is due to the added peak capacity and selectivity provided by the 3D column with GC3-TOFMS resulting in improved chromatographic resolution.
Collapse
Affiliation(s)
- Sonia Schöneich
- Department of Chemistry, University of Washington, Box 351700, Seattle, WA 98195, USA
| | - Caitlin N Cain
- Department of Chemistry, University of Washington, Box 351700, Seattle, WA 98195, USA
| | - Paige E Sudol
- Department of Chemistry, University of Washington, Box 351700, Seattle, WA 98195, USA
| | - Robert E Synovec
- Department of Chemistry, University of Washington, Box 351700, Seattle, WA 98195, USA.
| |
Collapse
|
2
|
Nolvachai Y, Amaral MSS, Marriott PJ. Foods and Contaminants Analysis Using Multidimensional Gas Chromatography: An Update of Recent Studies, Technology, and Applications. Anal Chem 2023; 95:238-263. [PMID: 36625115 DOI: 10.1021/acs.analchem.2c04680] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Affiliation(s)
- Yada Nolvachai
- Australian Centre for Research on Separation Science, School of Chemistry, Monash University, Wellington Road, Clayton, Victoria 3800, Australia
| | - Michelle S S Amaral
- Australian Centre for Research on Separation Science, School of Chemistry, Monash University, Wellington Road, Clayton, Victoria 3800, Australia
| | - Philip J Marriott
- Australian Centre for Research on Separation Science, School of Chemistry, Monash University, Wellington Road, Clayton, Victoria 3800, Australia
| |
Collapse
|
3
|
Cai H, Stearns SD. Comprehensive two-dimensional gas chromatography using direct flow modulation to extend the secondary dimension separation time. J Chromatogr A 2022; 1669:462930. [DOI: 10.1016/j.chroma.2022.462930] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Revised: 03/01/2022] [Accepted: 03/02/2022] [Indexed: 11/16/2022]
|
4
|
Sudol PE, Galletta M, Tranchida PQ, Zoccali M, Mondello L, Synovec RE. Untargeted profiling and differentiation of geographical variants of wine samples using headspace solid-phase microextraction flow-modulated comprehensive two-dimensional gas chromatography with the support of tile-based Fisher ratio analysis. J Chromatogr A 2021; 1662:462735. [PMID: 34936905 DOI: 10.1016/j.chroma.2021.462735] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Revised: 11/29/2021] [Accepted: 12/02/2021] [Indexed: 12/25/2022]
Abstract
The volatile fraction of food, also called the food volatilome, is increasingly used to develop new fingerprinting approaches. The characterization of the food volatilome is important to achieve desired flavor profiles in food production processes, or to differentiate different products, with winemaking being one popular area of interest. In the present research, headspace solid-phase microextraction (HS SPME) coupled to flow-modulated comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry (FM GC×GC-TOFMS) was used to characterize geographical-based differences in the volatilome of five white "Grillo" wines (of Sicilian origin), comprising the five sample classes. All wines were produced with the same vinification method in 2019. To minimize the influence of minor bottle-to-bottle differences, three bottles of the same wine were randomly selected, and three samples were collected per bottle, resulting in nine sample replicates per wine. Particular emphasis was devoted to the operational conditions of a novel low duty cycle flow modulator. A fast FM GC×GC-TOFMS method with a modulation period of 700 ms and a re-injection period of 80 ms was developed. Following, the instrumental software was exploited to identify class-distinguishing analytes in the dataset via tile-based Fisher ratio analysis (i.e., ChromaTOF Tile). A tile size of 10 modulations (7 s) on the first dimension and 45 spectra (300 ms) on the second dimension was used to encompass average peak widths and to account for minor retention time shifting. Off-line software was used to apply an ANOVA test. A p-value of 0.01 was applied in order to select the most important class-distinguishing analytes, which were input to principal component analysis (PCA). The PCA scores plot showed distinct clustering of the wines according to geographical origin, although the loadings revealed that only a few analytes were necessary to differentiate the wines. However, a comprehensive flavor profile assessment underscored the importance of all the information output by the ChromaTOF Tile software.
Collapse
Affiliation(s)
- Paige E Sudol
- Department of Chemistry, Box 351700, University of Washington, Seattle, WA 98195, United States of America
| | - Micaela Galletta
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Messina, Italy
| | - Peter Q Tranchida
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Messina, Italy
| | - Mariosimone Zoccali
- Department of Mathematical and Computer Science, Physical Sciences and Earth Sciences, University of Messina, Messina, Italy.
| | - Luigi Mondello
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Messina, Italy; Chromaleont s.r.l., c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Messina, Italy; BeSep s.r.l., c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Messina, Italy; Unit of Food Science and Nutrition, Department of Medicine, University Campus Bio-Medico of Rome, Rome, Italy
| | - Robert E Synovec
- Department of Chemistry, Box 351700, University of Washington, Seattle, WA 98195, United States of America
| |
Collapse
|
5
|
Vezzulli F, Bertuzzi T, Rastelli S, Mulazzi A, Lambri M. Sensory profile of Italian Espresso brewed Arabica Specialty Coffee under three roasting profiles with chemical and safety insight on roasted beans. Int J Food Sci Technol 2021. [DOI: 10.1111/ijfs.15380] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Affiliation(s)
- Fosca Vezzulli
- Department for Sustainable Food Process DiSTAS Università Cattolica del Sacro Cuore Via Emilia Parmense 84 Piacenza 29122 Italy
| | - Terenzio Bertuzzi
- Department of Animal, Nutrition and Food Sciences DiANA Università Cattolica del Sacro Cuore Via Emilia Parmense 84 Piacenza 29122 Italy
| | - Silvia Rastelli
- Department of Animal, Nutrition and Food Sciences DiANA Università Cattolica del Sacro Cuore Via Emilia Parmense 84 Piacenza 29122 Italy
| | - Annalisa Mulazzi
- Department of Animal, Nutrition and Food Sciences DiANA Università Cattolica del Sacro Cuore Via Emilia Parmense 84 Piacenza 29122 Italy
| | - Milena Lambri
- Department for Sustainable Food Process DiSTAS Università Cattolica del Sacro Cuore Via Emilia Parmense 84 Piacenza 29122 Italy
| |
Collapse
|
6
|
Mikaliunaite L, Sudol PE, Cain CN, Synovec RE. Baseline correction method for dynamic pressure gradient modulated comprehensive two-dimensional gas chromatography with flame ionization detection. J Chromatogr A 2021; 1652:462358. [PMID: 34237483 DOI: 10.1016/j.chroma.2021.462358] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Revised: 06/16/2021] [Accepted: 06/17/2021] [Indexed: 11/18/2022]
Abstract
A baseline correction method is developed for comprehensive two-dimensional (2D) chromatography (GC × GC) with flame-ionization detection (FID) using dynamic pressure gradient modulation (DPGM). The DPGM-GC × GC-FID utilized porous layer open tubular (PLOT) columns in both dimensions to focus on light hydrocarbon separations. Since DPGM is nominally a stop-flow modulation technique, a rhythmic baseline disturbance is observed in the FID signal that cycles with the modulation period (PM). This baseline disturbance needs to be corrected to optimize trace analysis. The baseline correction method has three steps: collection of a background "blank" chromatogram and multiplying it by an optimized normalization factor, subtraction of the normalization-optimized background chromatogram from a sample chromatogram, and application of Savitzky-Golay smoothing. An alkane standard solution, containing pentane, hexane and heptane was used for method development, producing linear calibration curves (r2 > 0.991) over a broad concentration range (7.8 ppm - 4000 ppm). Further, the limit-of-detection (LOD) and limit-of-quantification (LOQ) were determined for pentane (LOD = 2.5 ppm, LOQ = 8.2 ppm), hexane (LOD = 0.9 ppm, LOQ = 3.0 ppm), and heptane (LOD = 1.9 ppm, LOQ = 6.4 ppm). A natural gas sample separation illustrated method applicability, whereby the DPGM produced a signal enhancement (SE) of 30 for isopentane, where SE is defined as the height of the tallest 2D peak in the modulated chromatogram for the analyte divided by the height of the unmodulated 1D peak. The 30-fold SE resulted in about a 10-fold improvement in the signal-to-noise ratio (S/N) for isopentane. Additional versatility of the baseline correction method for more complicated samples was demonstrated for an unleaded gasoline sample, which enabled the detection (and visual appearance) of trace components.
Collapse
Affiliation(s)
- Lina Mikaliunaite
- Department of Chemistry, University of Washington, Box 351700, Seattle, WA 98195, USA
| | - Paige E Sudol
- Department of Chemistry, University of Washington, Box 351700, Seattle, WA 98195, USA
| | - Caitlin N Cain
- Department of Chemistry, University of Washington, Box 351700, Seattle, WA 98195, USA
| | - Robert E Synovec
- Department of Chemistry, University of Washington, Box 351700, Seattle, WA 98195, USA.
| |
Collapse
|
7
|
Trinklein TJ, Warren CG, Synovec RE. Determination of the Signal-To-Noise Ratio Enhancement in Comprehensive Three-Dimensional Gas Chromatography. Anal Chem 2021; 93:8526-8535. [PMID: 34097388 DOI: 10.1021/acs.analchem.1c01190] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
We investigate the extent to which comprehensive three-dimensional gas chromatography (GC3) provides a signal enhancement (SE) and a signal-to-noise ratio enhancement (S/NRel) relative to one-dimensional (1D)-GC. Specifically, the SE is defined as the ratio of the tallest 3D peak height from the GC3 separation to the 1D peak height from the unmodulated 1D-GC separation. A model is proposed which allows the analyst to predict the theoretically attainable SE (SET) based upon the peak width and sampling density inputs. The model is validated via comparison of the SET to the experimentally measured SE (SEM) obtained using total-transfer GC3 (100% duty cycle for both modulators) with time-of-flight mass spectrometry detection. Two experimental conditions were studied using the same GC3 column set, differing principally in the modulation period from the 1D to 2D columns: 4 s versus 8 s. Under the first set of conditions, the average SEM was 97 (±22), in excellent agreement with the SET of 97 (±18). The second set of conditions improved the average SEM to 181 (±27), also in agreement with the average SET of 176 (±26). The average S/NRel following correction for the mass spectrum acquisition frequency was 38.8 (±11.2) and 59.0 (±27.2) for the two sets of conditions. The enhancement in S/N is largely attributed to moving the signal to a higher frequency domain where the impact of "low frequency" noise is less detrimental. The findings here provide strong evidence that GC3 separations can provide enhanced detectability relative to 1D-GC and comprehensive two-dimensional gas chromatography (GC×GC) separations.
Collapse
Affiliation(s)
- Timothy J Trinklein
- Department of Chemistry, University of Washington, Box 351700, Seattle, Washington 98195-1700, United States
| | - Cable G Warren
- Department of Chemistry, University of Washington, Box 351700, Seattle, Washington 98195-1700, United States
| | - Robert E Synovec
- Department of Chemistry, University of Washington, Box 351700, Seattle, Washington 98195-1700, United States
| |
Collapse
|
8
|
Zanella D, Focant J, Franchina FA. 30 th Anniversary of comprehensive two-dimensional gas chromatography: Latest advances. ANALYTICAL SCIENCE ADVANCES 2021; 2:213-224. [PMID: 38716448 PMCID: PMC10989587 DOI: 10.1002/ansa.202000142] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/06/2020] [Revised: 11/27/2020] [Accepted: 11/30/2020] [Indexed: 08/31/2024]
Abstract
In this review, we report on the latest (2020-Early 2021) instrumental advances and applications of comprehensive two-dimensional gas chromatography (GC×GC), including its hyphenation with novel upstream or downstream processes (sample preparation approaches or detection technologies). We also discuss software and analysis workflow developments necessary to elaborate the dense chemical information obtained. Thirty years after its inception, the use of GC×GC, as the main analytical tool or as a complementary platform, is undoubtedly shifting toward more applied challenges in a vast breadth of applications. Therefore, we consider the major fields (energy, fuel, foodstuff, plant, biological, and environmental) in which GC×GC has been successfully used, discussing some of the recent innovative research works.
Collapse
Affiliation(s)
- Delphine Zanella
- Molecular System, Organic & Biological Analytical Chemistry GroupUniversity of LiègeLiègeBelgium
| | - Jean‐François Focant
- Molecular System, Organic & Biological Analytical Chemistry GroupUniversity of LiègeLiègeBelgium
| | - Flavio A. Franchina
- Molecular System, Organic & Biological Analytical Chemistry GroupUniversity of LiègeLiègeBelgium
| |
Collapse
|
9
|
Trinklein TJ, Schöneich S, Sudol PE, Warren CG, Gough DV, Synovec RE. Total-transfer comprehensive three-dimensional gas chromatography with time-of-flight mass spectrometry. J Chromatogr A 2020; 1634:461654. [DOI: 10.1016/j.chroma.2020.461654] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Revised: 10/19/2020] [Accepted: 10/26/2020] [Indexed: 12/25/2022]
|