1
|
Shi A, Tang X, Liu L, Qi B, Wang C, Jia Z. Qualitative and quantitative analyses of the changes in the chemical composition of frankincense before and after stir-frying using GC-MS and LC-MS. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2025; 17:2191-2202. [PMID: 39963767 DOI: 10.1039/d4ay01742k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/28/2025]
Abstract
Frankincense is a resin drug used widely in the medical field. Comprehensive qualitative and quantitative analyses of the differences in the chemical composition of frankincense, stir-fried frankincense and vinegar frankincense were done by combining GC-MS and LC-MS. GC-MS revealed six chemical compositions with high content in frankincense: β-ocimene, 1-octanol, acetic acid, octyl ester, nerolidol, lauric acid and incensole acetate. LC-MS revealed eight more widely studied chemical compositions: 11-keto-β-boswellic acid, β-elemolic acid, acetyl-11-keto-β-boswellic acid, β-elemonic acid, α-boswellic acid, β-boswellic acid, 3-O-acetyl-α-boswellic acid and 3-O-acetyl-β-boswellic acid. In addition, the chemical composition of frankincense was identified by the fragmentation information afforded by LC-MS.
Collapse
Affiliation(s)
- Aiwen Shi
- School of Pharmacy, Changchun University of Chinese Medicine, No. 1035 Boshuo Road, Nanguan District, Changchun, China.
| | - Xiaolei Tang
- Affiliated Hospital of Changchun University of Chinese Medicine, No. 1035 Boshuo Road, Changchun, China
| | - Li Liu
- School of Pharmacy, Changchun University of Chinese Medicine, No. 1035 Boshuo Road, Nanguan District, Changchun, China.
| | - Bin Qi
- School of Pharmacy, Changchun University of Chinese Medicine, No. 1035 Boshuo Road, Nanguan District, Changchun, China.
| | - Chang Wang
- Ginseng Research Institute Changchun University of Chinese Medicine, No. 1035 Boshuo Road, Nanguan District, Changchun, China
| | - Ziyi Jia
- School of Pharmacy, Changchun University of Chinese Medicine, No. 1035 Boshuo Road, Nanguan District, Changchun, China.
| |
Collapse
|
2
|
Sarkar J, Singh R, Chandel S. Understanding LC/MS-Based Metabolomics: A Detailed Reference for Natural Product Analysis. Proteomics Clin Appl 2025; 19:e202400048. [PMID: 39474988 DOI: 10.1002/prca.202400048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2024] [Revised: 10/06/2024] [Accepted: 10/10/2024] [Indexed: 01/14/2025]
Abstract
Liquid chromatography, when used in conjunction with mass spectrometry (LC/MS), is a powerful tool for conducting accurate and reproducible investigations of numerous metabolites in natural products (NPs). LC/MS has gained prominence in metabolomic research due to its high throughput, the availability of multiple ionization techniques and its ability to provide comprehensive metabolite coverage. This unique method can significantly influence various scientific domains. This review offers a comprehensive overview of the current state of LC/MS-based metabolomics in the investigation of NPs. This review provides a thorough overview of the state of the art in LC/MS-based metabolomics for the investigation of NPs. It covers the principles of LC/MS, various aspects of LC/MS-based metabolomics such as sample preparation, LC modes, method development, ionization techniques and data pre-processing. Moreover, it presents the applications of LC/MS-based metabolomics in numerous fields of NPs research such as including biomarker discovery, the agricultural research, food analysis, the study of marine NPs and microbiological research. Additionally, this review discusses the challenges and limitations of LC/MS-based metabolomics, as well as emerging trends and developments in this field.
Collapse
Affiliation(s)
- Jyotirmay Sarkar
- Department of Pharmacognosy, ISF College of Pharmacy, Moga, Punjab, India
| | - Rajveer Singh
- Department of Pharmacognosy, ISF College of Pharmacy, Moga, Punjab, India
| | - Shivani Chandel
- Department of Pharmacognosy, ISF College of Pharmacy, Moga, Punjab, India
| |
Collapse
|
3
|
Peng Z, Wang Y, Wu X, Yang S, Du X, Xu X, Hu C, Liu W, Zhu Y, Dong B, Pan J, Bao Q, Qian K, Dong L, Xue W. Identifying High Gleason Score Prostate Cancer by Prostate Fluid Metabolic Fingerprint-Based Multi-Modal Recognition. SMALL METHODS 2024; 8:e2301684. [PMID: 38258603 DOI: 10.1002/smtd.202301684] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Revised: 01/09/2024] [Indexed: 01/24/2024]
Abstract
Prostate cancer (PCa) is the second most common cancer in males worldwide. The Gleason scoring system, which classifies the pathological growth pattern of cancer, is considered one of the most important prognostic factors for PCa. Compared to indolent PCa, PCa with high Gleason score (h-GS PCa, GS ≥ 8) has greater clinical significance due to its high aggressiveness and poor prognosis. It is crucial to establish a rapid, non-invasive diagnostic modality to decipher patients with h-GS PCa as early as possible. In this study, ferric nanoparticle-assisted laser desorption/ionization mass spectrometry (FeNPALDI-MS) to extract prostate fluid metabolic fingerprint (PSF-MF) is employed and combined with the clinical features of patients, such as prostate-specific antigen (PSA), to establish a multi-modal diagnosis assisted by machine learning. This approach yields an impressive area under the curve (AUC) of 0.87 to diagnose patients with h-GS, surpassing the results of single-modal diagnosis using only PSF-MF or PSA, respectively. Additionally, using various screening methods, six key metabolites that exhibit greater diagnostic efficacy (AUC = 0.96) are identified. These findings also provide insights into related metabolic pathways, which may provide valuable information for further elucidation of the pathological mechanisms underlying h-GS PCa.
Collapse
Affiliation(s)
- Zehong Peng
- Department of Urology, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, 160 Pujian Road, Shanghai, 200127, P. R. China
| | - Yuning Wang
- State Key Laboratory of Systems Medicine for Cancer, School of Biomedical Engineering and Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, 200030, P. R. China
| | - Xinrui Wu
- Department of Urology, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, 160 Pujian Road, Shanghai, 200127, P. R. China
| | - Shouzhi Yang
- State Key Laboratory of Systems Medicine for Cancer, School of Biomedical Engineering and Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, 200030, P. R. China
| | - Xinxing Du
- Department of Urology, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, 160 Pujian Road, Shanghai, 200127, P. R. China
| | - Xiaoyu Xu
- State Key Laboratory of Systems Medicine for Cancer, School of Biomedical Engineering and Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, 200030, P. R. China
| | - Cong Hu
- Department of Urology, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, 160 Pujian Road, Shanghai, 200127, P. R. China
| | - Wanshan Liu
- State Key Laboratory of Systems Medicine for Cancer, School of Biomedical Engineering and Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, 200030, P. R. China
| | - Yinjie Zhu
- Department of Urology, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, 160 Pujian Road, Shanghai, 200127, P. R. China
| | - Baijun Dong
- Department of Urology, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, 160 Pujian Road, Shanghai, 200127, P. R. China
| | - Jiahua Pan
- Department of Urology, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, 160 Pujian Road, Shanghai, 200127, P. R. China
| | - Qingui Bao
- Fosun Diagnostics (Shanghai) Co., Ltd., No. 830, Chengyin Road, Baoshan, Shanghai, 200435, P. R. China
| | - Kun Qian
- State Key Laboratory of Systems Medicine for Cancer, School of Biomedical Engineering and Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, 200030, P. R. China
| | - Liang Dong
- Department of Urology, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, 160 Pujian Road, Shanghai, 200127, P. R. China
| | - Wei Xue
- Department of Urology, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, 160 Pujian Road, Shanghai, 200127, P. R. China
| |
Collapse
|
4
|
Boillat MA, Hauser PC. Study of a microwave induced plasma as a universal ion source for inorganic and organic mass spectrometry. Analyst 2024; 149:4213-4221. [PMID: 38864551 DOI: 10.1039/d4an00356j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/13/2024]
Abstract
A proof-of-concept study of the utilization of a single mass spectrometer for qualitative molecular analysis as well as for quantitative metal determination is described. This was performed with an argon microwave plasma as the ion source coupled to an ion trap mass spectrometer. A microwave induced plasma with tuneable power and gas flow rate was loaded with dried nebulized sample solutions. The commercially available plasma torch was slightly modified to allow the introduction of the sample in different regions of the plasma. Using soft settings, organic compounds introduced in the plasma plume could be detected as protonated molecular ions. Under harsher conditions, elemental analysis was demonstrated for several metals. Lead could be determined with a limit of detection of 150 nM. Minor on-the-fly adjustments of the power, flow rate and sampling distance allowed a mild fragmentation of organic compounds. Ionization differences observed were rationalized by emission spectroscopy, and excitation and rotational temperatures were determined. Simultaneous determination of elemental and molecular information was demonstrated for a rubidium-crown-ether complex. The maximum argon gas consumption for these tasks was below 2 L min-1 and the maximal power used was 90 W.
Collapse
Affiliation(s)
- Marc-Aurèle Boillat
- University of Basel, Department of Chemistry, Klingelbergstrasse 80, 4056 Basel, Switzerland.
| | - Peter C Hauser
- University of Basel, Department of Chemistry, Klingelbergstrasse 80, 4056 Basel, Switzerland.
| |
Collapse
|
5
|
Grasselli G, Arigò A, Palma P, Famiglini G, Cappiello A. Latest Developments in Direct and Non-Direct LC-MS Methods Based on Liquid Electron Ionization (LEI). Crit Rev Anal Chem 2024:1-18. [PMID: 39046707 DOI: 10.1080/10408347.2024.2381543] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/25/2024]
Abstract
Mass spectrometry (MS) enables precise identification and quantification of molecules, particularly when combined with chromatography. The advent of atmospheric pressure ionization (API) techniques allowed the efficient coupling of liquid chromatography with MS (LC-MS), extending analyses to nonvolatile and thermolabile compounds. API techniques present limitations such as low informative capacity and reproducibility of mass spectra, increasing instrument complexity and costs. Other challenges include analyzing poorly polar molecules and matrix effects (ME), which negatively impact quantitative analyses, necessitating extensive sample purification or using expensive labeled standards. These limitations prompted the exploration of alternative solutions, leading to the development of the Liquid Electron Ionization (LEI) interface. The system has demonstrated excellent robustness and reproducibility. LEI has been employed to analyze various compounds, including pesticides, drugs of abuse, phenols, polycyclic aromatic hydrocarbons (PAHs), phthalates, and many others. Its versatility has been validated with single quadrupole, triple quadrupole, and QToF detectors, operating in electron ionization (EI) or chemical ionization (CI) modes and with both reverse phase liquid chromatography (RPLC) and normal phase liquid chromatography (NPLC). LEI has also been successfully integrated with the Microfluidic Open Interface (MOI), Membrane Introduction Mass Spectrometry (MIMS), and Microfluidic Water-Assisted Trap Focusing (M-WATF), broadening its application scope and consistently demonstrating promising results in terms of sensitivity and identification power. The most recent advancement is the development of Extractive-Liquid Sampling Electron Ionization-Mass Spectrometry (E-LEI-MS), a surface sampling and real-time analysis technique based on the LEI concept. This review article offers a comprehensive and up-to-date picture of the potential of LEI.
Collapse
Affiliation(s)
- Genny Grasselli
- Department of Pure and Applied Sciences, University of Urbino Carlo Bo, Urbino, Italy
| | - Adriana Arigò
- Department of Pure and Applied Sciences, University of Urbino Carlo Bo, Urbino, Italy
| | - Pierangela Palma
- Department of Pure and Applied Sciences, University of Urbino Carlo Bo, Urbino, Italy
| | - Giorgio Famiglini
- Department of Pure and Applied Sciences, University of Urbino Carlo Bo, Urbino, Italy
| | - Achille Cappiello
- Department of Pure and Applied Sciences, University of Urbino Carlo Bo, Urbino, Italy
| |
Collapse
|
6
|
Piergiovanni M, Gosetti F, Rocío-Bautista P, Termopoli V. Aroma determination in alcoholic beverages: Green MS-based sample preparation approaches. MASS SPECTROMETRY REVIEWS 2024; 43:660-682. [PMID: 35980114 DOI: 10.1002/mas.21802] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Revised: 07/12/2022] [Accepted: 07/15/2022] [Indexed: 06/15/2023]
Abstract
Aroma determination in alcoholic beverages has become a hot research topic due to the ongoing effort to obtain quality products, especially in a globalized market. Consumer satisfaction is mainly achieved by balancing several aroma compounds, which are mixtures of numerous volatile molecules enclosed in challenging matrices. Thus, sample preparation strategies for quality control and product development are required. They involve several steps including copious amounts of hazardous solvents or time-consuming procedures. This is bucking the trend of the ever-increasing pressure to reduce the environmental impact of analytical chemistry processes. Hence, the evolution of sample preparation procedures has directed towards miniaturized techniques to decrease or avoid the use of hazardous solvents and integrating sampling, extraction, and enrichment of the targeted analytes in fewer steps. Mass spectrometry coupled to gas or liquid chromatography is particularly well suited to address the complexity of these matrices. This review surveys advancements of green miniaturized techniques coupled to mass spectrometry applied on all categories of odor-active molecules in the most consumed alcoholic beverages: beer, wine, and spirits. The targeted literature consider progresses over the past 20 years.
Collapse
Affiliation(s)
- Maurizio Piergiovanni
- Centre Agriculture Food Environment (C3A), University of Trento, San Michele all'Adige, Italy
| | - Fabio Gosetti
- Department of Earth and Environmental Sciences, University of Milano-Bicocca, Milano, Italy
| | - Priscilla Rocío-Bautista
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Jaén, Spain
| | - Veronica Termopoli
- Department of Earth and Environmental Sciences, University of Milano-Bicocca, Milano, Italy
| |
Collapse
|
7
|
Al-Daffaie FM, Al-Mudhafar SF, Alhomsi A, Tarazi H, Almehdi AM, El-Huneidi W, Abu-Gharbieh E, Bustanji Y, Alqudah MAY, Abuhelwa AY, Guella A, Alzoubi KH, Semreen MH. Metabolomics and Proteomics in Prostate Cancer Research: Overview, Analytical Techniques, Data Analysis, and Recent Clinical Applications. Int J Mol Sci 2024; 25:5071. [PMID: 38791108 PMCID: PMC11120916 DOI: 10.3390/ijms25105071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Revised: 04/26/2024] [Accepted: 04/26/2024] [Indexed: 05/26/2024] Open
Abstract
Prostate cancer (PCa) is a significant global contributor to mortality, predominantly affecting males aged 65 and above. The field of omics has recently gained traction due to its capacity to provide profound insights into the biochemical mechanisms underlying conditions like prostate cancer. This involves the identification and quantification of low-molecular-weight metabolites and proteins acting as crucial biochemical signals for early detection, therapy assessment, and target identification. A spectrum of analytical methods is employed to discern and measure these molecules, revealing their altered biological pathways within diseased contexts. Metabolomics and proteomics generate refined data subjected to detailed statistical analysis through sophisticated software, yielding substantive insights. This review aims to underscore the major contributions of multi-omics to PCa research, covering its core principles, its role in tumor biology characterization, biomarker discovery, prognostic studies, various analytical technologies such as mass spectrometry and Nuclear Magnetic Resonance, data processing, and recent clinical applications made possible by an integrative "omics" approach. This approach seeks to address the challenges associated with current PCa treatments. Hence, our research endeavors to demonstrate the valuable applications of these potent tools in investigations, offering significant potential for understanding the complex biochemical environment of prostate cancer and advancing tailored therapeutic approaches for further development.
Collapse
Affiliation(s)
- Fatima M. Al-Daffaie
- Department of Medicinal Chemistry, College of Pharmacy, University of Sharjah, Sharjah 27272, United Arab Emirates; (F.M.A.-D.); (S.F.A.-M.); (A.A.); (H.T.); (A.M.A.)
- Research Institute of Medical and Health Sciences, University of Sharjah, Sharjah 27272, United Arab Emirates; (W.E.-H.); (E.A.-G.); (A.Y.A.); (K.H.A.)
| | - Sara F. Al-Mudhafar
- Department of Medicinal Chemistry, College of Pharmacy, University of Sharjah, Sharjah 27272, United Arab Emirates; (F.M.A.-D.); (S.F.A.-M.); (A.A.); (H.T.); (A.M.A.)
| | - Aya Alhomsi
- Department of Medicinal Chemistry, College of Pharmacy, University of Sharjah, Sharjah 27272, United Arab Emirates; (F.M.A.-D.); (S.F.A.-M.); (A.A.); (H.T.); (A.M.A.)
| | - Hamadeh Tarazi
- Department of Medicinal Chemistry, College of Pharmacy, University of Sharjah, Sharjah 27272, United Arab Emirates; (F.M.A.-D.); (S.F.A.-M.); (A.A.); (H.T.); (A.M.A.)
- Research Institute of Medical and Health Sciences, University of Sharjah, Sharjah 27272, United Arab Emirates; (W.E.-H.); (E.A.-G.); (A.Y.A.); (K.H.A.)
| | - Ahmed M. Almehdi
- Department of Medicinal Chemistry, College of Pharmacy, University of Sharjah, Sharjah 27272, United Arab Emirates; (F.M.A.-D.); (S.F.A.-M.); (A.A.); (H.T.); (A.M.A.)
- Research Institute of Medical and Health Sciences, University of Sharjah, Sharjah 27272, United Arab Emirates; (W.E.-H.); (E.A.-G.); (A.Y.A.); (K.H.A.)
| | - Waseem El-Huneidi
- Research Institute of Medical and Health Sciences, University of Sharjah, Sharjah 27272, United Arab Emirates; (W.E.-H.); (E.A.-G.); (A.Y.A.); (K.H.A.)
- Department of Basic Medical Sciences, College of Medicine, University of Sharjah, Sharjah 27272, United Arab Emirates;
| | - Eman Abu-Gharbieh
- Research Institute of Medical and Health Sciences, University of Sharjah, Sharjah 27272, United Arab Emirates; (W.E.-H.); (E.A.-G.); (A.Y.A.); (K.H.A.)
- Department of Clinical Sciences, College of Medicine, University of Sharjah, Sharjah 27272, United Arab Emirates
- School of Pharmacy, The University of Jordan, Amman 11942, Jordan
| | - Yasser Bustanji
- Department of Basic Medical Sciences, College of Medicine, University of Sharjah, Sharjah 27272, United Arab Emirates;
- School of Pharmacy, The University of Jordan, Amman 11942, Jordan
| | - Mohammad A. Y. Alqudah
- Department of Pharmacy Practice and Pharmacotherapeutics, College of Pharmacy, University of Sharjah, Sharjah 27272, United Arab Emirates;
- Department of Clinical Pharmacy, Faculty of Pharmacy, Jordan University of Science and Technology, Irbid 22110, Jordan
| | - Ahmad Y. Abuhelwa
- Research Institute of Medical and Health Sciences, University of Sharjah, Sharjah 27272, United Arab Emirates; (W.E.-H.); (E.A.-G.); (A.Y.A.); (K.H.A.)
- Department of Pharmacy Practice and Pharmacotherapeutics, College of Pharmacy, University of Sharjah, Sharjah 27272, United Arab Emirates;
| | - Adnane Guella
- Nephrology Department, University Hospital Sharjah, Sharjah 27272, United Arab Emirates;
| | - Karem H. Alzoubi
- Research Institute of Medical and Health Sciences, University of Sharjah, Sharjah 27272, United Arab Emirates; (W.E.-H.); (E.A.-G.); (A.Y.A.); (K.H.A.)
- Department of Pharmacy Practice and Pharmacotherapeutics, College of Pharmacy, University of Sharjah, Sharjah 27272, United Arab Emirates;
| | - Mohammad H. Semreen
- Department of Medicinal Chemistry, College of Pharmacy, University of Sharjah, Sharjah 27272, United Arab Emirates; (F.M.A.-D.); (S.F.A.-M.); (A.A.); (H.T.); (A.M.A.)
- Research Institute of Medical and Health Sciences, University of Sharjah, Sharjah 27272, United Arab Emirates; (W.E.-H.); (E.A.-G.); (A.Y.A.); (K.H.A.)
| |
Collapse
|
8
|
Chen F, Wang Z, Luo L, He Y, Ma Y, Wen C, Wang X, Shen X. Development of an ultra-high-performance liquid chromatography-tandem mass spectrometry method for the simultaneous determination of crassicauline A, fuziline, karacoline, and songorine in rat plasma and application in their pharmacokinetics. Biomed Chromatogr 2024; 38:e5821. [PMID: 38217347 DOI: 10.1002/bmc.5821] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2023] [Revised: 12/07/2023] [Accepted: 12/11/2023] [Indexed: 01/15/2024]
Abstract
In this paper, an ultra-high-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed for quantifying the levels of crassicauline A, fuziline, karacoline, and songorine in rat plasma. After processing the rat plasma, the proteins in the plasma were separated by extracting the analytes with acetonitrile-methanol (9:1, v/v). The chromatographic column used was the UPLC HSS T3 column, and the mobile phase (methanol-water with 0.1% formic acid) under a gradient elution profile was used to separate the four compounds, with elution times for each analyte being less than 5 min. Electrospray ionization in positive-ion mode and operating in multiple reaction monitoring mode was used for quantitative analysis. Crassicauline A, fuziline, karacoline, and songorine were administered to 48 rats (n = 6 per group) orally (5 mg/kg) and intravenously (0.5 mg/kg). The standard curves demonstrated excellent linearity in the range of 1-2500 ng/mL, wherein all r values were greater than 0.99. The UPLC-MS/MS method for the determination of crassicauline A, fuziline, karacoline, and songorine in rat plasma was successfully applied in determining their pharmacokinetics parameters, from which their oral bioavailabilities were calculated to be 18.7%, 4.3%, 6.0%, and 8.4%, respectively.
Collapse
Affiliation(s)
- Fan Chen
- Ruian People's Hospital, The Third Affiliated Hospital of Wenzhou Medical University, Wenzhou, China
| | - Ziyue Wang
- Laboratory Animal Centre, Wenzhou Medical University, Wenzhou, China
| | - Lvqi Luo
- Laboratory Animal Centre, Wenzhou Medical University, Wenzhou, China
| | - Yifan He
- Laboratory Animal Centre, Wenzhou Medical University, Wenzhou, China
| | - Yizhe Ma
- Laboratory Animal Centre, Wenzhou Medical University, Wenzhou, China
| | - Congcong Wen
- Laboratory Animal Centre, Wenzhou Medical University, Wenzhou, China
| | - Xianqin Wang
- School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou, China
| | - Xiuwei Shen
- Ruian People's Hospital, The Third Affiliated Hospital of Wenzhou Medical University, Wenzhou, China
| |
Collapse
|
9
|
Sanz Rodriguez E, Wood K, Haddad PR, Paull B. Boron quantification using ion chromatography tandem triple quadrupole mass spectrometry. Application to retention analysis in boron-treated wood. Talanta 2024; 268:125377. [PMID: 37956558 DOI: 10.1016/j.talanta.2023.125377] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Revised: 10/16/2023] [Accepted: 10/31/2023] [Indexed: 11/15/2023]
Abstract
Boron compounds play a crucial role in various industries, and accurate quantification of boron is essential for quality control and environmental monitoring. This study presents a simple, rapid, and reliable method for determining boron in aqueous solutions using suppressed ion chromatography coupled to electrospray ionisation-triple quadrupole mass spectrometry (IC-ESI-QqQ-MS). Boric acid (B(OH)3) was retained as the tetrahydroxyborate ion (B(OH)4-) on a CarboPac PA300-4 μm anion-exchange column using isocratic elution with 40 mM KOH. During the neutralization process at the suppressor, B(OH)4- was converted to B(OH)3, which subsequently generated the metaborate ion [BO2]- (m/z 43) within the electrospray ionisation source. By employing a pseudo-selected reaction monitoring (SRM) transition from m/z 43 to m/z 43, the method achieved a limit of detection (LOD) of 2.45 μg/L of boron, the lowest reported in the literature to-date for an IC-based method. The analytical performance of the method demonstrated no carry-over issues, no matrix interferences, and excellent intra- and inter-run repeatability of 2.03% and 3.41%, respectively. The method was applied to the evaluation of boron uptake and retention by Tasmanian Oak timber blocks, treated by dip-diffusion in a boric acid solution of 2.5% Boric Acid Equivalent (BAE, m/m) under controlled laboratory conditions. Quantitative determination of the retained and unretained boron allowed a mass balance evaluation and confirmed the accuracy and reliability of the method, with recoveries ranging from 99.3% to 100.2%.
Collapse
Affiliation(s)
- Estrella Sanz Rodriguez
- Australian Centre for Research on Separation Science (ACROSS), Chemistry, School of Natural Sciences, College of Sciences and Engineering, University of Tasmania, Hobart, Tasmania, 7001, Australia.
| | - Kyra Wood
- Centre for Sustainable Architecture with Wood, School of Architecture and Design, College of Sciences and Engineering, University of Tasmania, Newnham, Tasmania, 7248, Australia
| | - Paul R Haddad
- Australian Centre for Research on Separation Science (ACROSS), Chemistry, School of Natural Sciences, College of Sciences and Engineering, University of Tasmania, Hobart, Tasmania, 7001, Australia
| | - Brett Paull
- Australian Centre for Research on Separation Science (ACROSS), Chemistry, School of Natural Sciences, College of Sciences and Engineering, University of Tasmania, Hobart, Tasmania, 7001, Australia
| |
Collapse
|
10
|
Zhang Y, Wang Y. Machine learning applications for multi-source data of edible crops: A review of current trends and future prospects. Food Chem X 2023; 19:100860. [PMID: 37780348 PMCID: PMC10534232 DOI: 10.1016/j.fochx.2023.100860] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Revised: 08/23/2023] [Accepted: 08/31/2023] [Indexed: 10/03/2023] Open
Abstract
The quality and safety of edible crops are key links inseparable from human health and nutrition. In the era of rapid development of artificial intelligence, using it to mine multi-source information on edible crops provides new opportunities for industrial development and market supervision of edible crops. This review comprehensively summarized the applications of multi-source data combined with machine learning in the quality evaluation of edible crops. Multi-source data can provide more comprehensive and rich information from a single data source, as it can integrate different data information. Supervised and unsupervised machine learning is applied to data analysis to achieve different requirements for the quality evaluation of edible crops. Emphasized the advantages and disadvantages of techniques and analysis methods, the problems that need to be overcome, and promising development directions were proposed. To monitor the market in real-time, the quality evaluation methods of edible crops must be innovated.
Collapse
Affiliation(s)
- Yanying Zhang
- Medicinal Plants Research Institute, Yunnan Academy of Agricultural Sciences, Kunming 650200, China
- College of Traditional Chinese Medicine, Yunnan University of Chinese Medicine, Kunming 650500, China
| | - Yuanzhong Wang
- Medicinal Plants Research Institute, Yunnan Academy of Agricultural Sciences, Kunming 650200, China
| |
Collapse
|
11
|
Vargas Medina DA, Maciel EVS, Pereira Dos Santos NG, Lancas FM. The overshadowed role of electron ionization-mass spectrometry in analytical biotechnology. Curr Opin Biotechnol 2023; 82:102965. [PMID: 37393696 DOI: 10.1016/j.copbio.2023.102965] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 05/30/2023] [Accepted: 06/05/2023] [Indexed: 07/04/2023]
Abstract
Target and untargeted analysis of several compounds are crucial methods in important areas such as omics sciences. Gas chromatography coupled to mass spectrometry (GC-MS) is widely used for volatile and thermally stable compounds. In this case, the electron ionization technique (EI) is preferable as it produces highly fragmented and reproducible spectra comparable to spectral libraries. However, only a fraction of target compounds is analyzable by GC without chemical derivatization. Therefore, liquid chromatography (LC) coupled with MS is the most used technique. Contrary to EI, electrospray ionization does not produce reproducible spectra. That is why researchers have been working on interfaces between LC and EI-MS to bridge the gap between those techniques. This short review will discuss advancements, applications, and perspectives on biotechnological analysis.
Collapse
Affiliation(s)
- Deyber Arley Vargas Medina
- Laboratory of Chromatography, Institute of Chemistry at Sao Carlos, University of Sao Paulo, P.O Box 780, 13566590 Sao Carlos, Brazil; Clemens Schöpf Institute, Department of Chemistry, Technical University of Darmstadt, 64287 Darmstadt, Germany
| | - Edvaldo Vasconcelos Soares Maciel
- Laboratory of Chromatography, Institute of Chemistry at Sao Carlos, University of Sao Paulo, P.O Box 780, 13566590 Sao Carlos, Brazil; Clemens Schöpf Institute, Department of Chemistry, Technical University of Darmstadt, 64287 Darmstadt, Germany
| | - Natalia Gabrielly Pereira Dos Santos
- Laboratory of Chromatography, Institute of Chemistry at Sao Carlos, University of Sao Paulo, P.O Box 780, 13566590 Sao Carlos, Brazil; Clemens Schöpf Institute, Department of Chemistry, Technical University of Darmstadt, 64287 Darmstadt, Germany
| | - Fernando Mauro Lancas
- Laboratory of Chromatography, Institute of Chemistry at Sao Carlos, University of Sao Paulo, P.O Box 780, 13566590 Sao Carlos, Brazil.
| |
Collapse
|
12
|
Pereira Dos Santos NG, Maciel EVS, Vargas Medina DA, Lanças FM. NanoLC-EI-MS: Perspectives in Biochemical Analysis. Int J Mol Sci 2023; 24:11746. [PMID: 37511506 PMCID: PMC10380556 DOI: 10.3390/ijms241411746] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2023] [Revised: 07/14/2023] [Accepted: 07/18/2023] [Indexed: 07/30/2023] Open
Abstract
Although LC-MS with atmospheric pressure ionization (API) sources is the primary technique used in modern bioanalytical studies, electron ionization mass spectrometry (EI-MS) can provide some substantial advantages over it. EI-MS is a matrix effect-free technique that provides reproducible and comparable mass spectra, serving as a compound fingerprint for easy identification through automated comparison with spectral libraries. Leveraging EI-MS in biochemical studies can yield critical analytical benefits for targeted and untargeted analyses. However, to fully utilize EI-MS for heavy and non-volatile molecules, a new technology that enables the coupling of liquid chromatography with EI-MS is needed. Recent advancements in nanoLC have addressed the compatibility issues between LC and EI-MS, and innovative interfacing strategies such as Direct-EI, liquid electron ionization (LEI), and Cold-EI have extended the application of EI-MS beyond the determination of volatile organic molecules. This review provides an overview of the latest developments in nanoLC-EI-MS interfacing technologies, discussing their scope and limitations. Additionally, selected examples of nanoLC-EI-MS applications in the field of biochemical analysis are presented, highlighting the potential prospects and benefits that the establishment of this technique can bring to this field.
Collapse
Affiliation(s)
| | | | | | - Fernando Mauro Lanças
- Institute of Chemistry of São Carlos, University of São Paulo, São Carlos 13566-590, Brazil
| |
Collapse
|
13
|
Chen D, Xu X, Wang B, Bu X, Zhang M, Xu X, Shi N. Natural cotton fiber-supported liquid extraction for convenient protein-rich aqueous sample preparation: Determination of glucocorticoids in milk and plasma as a proof-of-concept study. Talanta 2023; 260:124618. [PMID: 37156209 DOI: 10.1016/j.talanta.2023.124618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Revised: 04/27/2023] [Accepted: 04/29/2023] [Indexed: 05/10/2023]
Abstract
Protein-rich aqueous samples such as milk and plasma usually require complex sample preparation steps prior to instrumental analysis. This study proposed a novel cotton fiber-supported liquid extraction (CF-SLE) method for convenient sample preparation. Natural cotton fiber was directly loaded into a syringe tube to conveniently construct the extraction device. No filter frits were required due to the fibrous feature of the cotton fibers. The cost of the extraction device was less than 0.5 CNY, and the costly syringe tube could be easily reused to decrease the cost further. Extraction used a simple two-step protocol: protein-rich aqueous sample loading and elution. Emulsification and centrifugation steps involved in the classic liquid-liquid extraction were avoided. As a proof-of-concept study, the glucocorticoids in milk and plasma were extracted with satisfactory extraction recoveries. Coupled with liquid chromatography-tandem mass spectrometry, a sensitive quantification method was established with excellent linearity (R2 > 0.991) as well as good accuracy (85.7-117.3%) and precision (<14.3%). This system is simple, low-cost, reproducible, and easy to automate. Thus, the proposed CF-SLE method is promising for the routine sample preparation of protein-rich aqueous samples prior to instrumental analysis.
Collapse
Affiliation(s)
- Di Chen
- School of Pharmaceutical Sciences, Zhengzhou University, Zhengzhou, 450001, China; Key Laboratory of Targeting Therapy and Diagnosis for Critical Diseases of Henan Province, Zhengzhou, 450001, China; National Key Laboratory of Cotton Bio-breeding and Integrated Utilization, Zhengzhou University, Zhengzhou 45001, China.
| | - Xinli Xu
- School of Pharmaceutical Sciences, Zhengzhou University, Zhengzhou, 450001, China
| | - Bin Wang
- School of Pharmaceutical Sciences, Zhengzhou University, Zhengzhou, 450001, China
| | - Xinmiao Bu
- School of Pharmaceutical Sciences, Zhengzhou University, Zhengzhou, 450001, China
| | - Manyu Zhang
- School of Pharmaceutical Sciences, Zhengzhou University, Zhengzhou, 450001, China
| | - Xia Xu
- School of Pharmaceutical Sciences, Zhengzhou University, Zhengzhou, 450001, China; Key Laboratory of Targeting Therapy and Diagnosis for Critical Diseases of Henan Province, Zhengzhou, 450001, China; National Key Laboratory of Cotton Bio-breeding and Integrated Utilization, Zhengzhou University, Zhengzhou 45001, China.
| | - Nian Shi
- Physics Diagnostic Division, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450052, China.
| |
Collapse
|
14
|
Arigò A, Famiglini G, Marittimo N, Agostini M, Renzoni C, Palma P, Cappiello A. Extractive-liquid sampling electron ionization-mass spectrometry (E-LEI-MS): a new powerful combination for direct analysis. Sci Rep 2023; 13:6429. [PMID: 37081134 PMCID: PMC10119378 DOI: 10.1038/s41598-023-33647-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Accepted: 04/17/2023] [Indexed: 04/22/2023] Open
Abstract
One of modern analytical chemistry main challenges is providing as fast as possible results in different application fields. In this view, real-time analysis techniques are experiencing ever-increasing success as they can provide data quickly, almost without sample preparation steps. Most of real-time approaches are based on direct mass spectrometry (DMS), a method of analyzing samples without the need for separation or pre-treatment steps. Instead, the sample is directly introduced into the mass spectrometer for analysis. In this context, ambient ionization mass spectrometry (AIMS) techniques are widely represented and successfully used. Extractive-liquid sampling electron ionization-mass spectrometry (E-LEI-MS) represents a different analytical strategy that allows coupling ambient sampling with electron ionization (EI), avoiding any sample preparation step and providing identification based on the comparison with the National Institute of Standards and Technology (NIST) library spectra. E-LEI-MS consists of a dispositive for solvent release and sampling at ambient conditions coupled with an EI source of a single quadrupole mass spectrometer. A micromanipulator allows fine (x,y,z) positioning of a sampling tip. MS can operate in scan or SIM modes depending on the application goals and requirements. Several preliminary successful results were already obtained due to the highly informative EI mass spectra generation. The system was applied to the analysis of active ingredients in pharmaceutical tablets, pesticides on fruit peel, a drug of abuse (cocaine) determination in banknotes, and analysis of unknown components on painting surfaces. Both forensic and artwork applications allowed determining the spatial distribution of the analytes. Here we present a proof-of-concept of E-LEI-MS for targeted/non-targeted analysis and semi-quantitative detection.
Collapse
Affiliation(s)
- Adriana Arigò
- LC-MS Lab, Department of Pure and Applied Sciences, University of Urbino Carlo Bo, Piazza Rinascimento 6, 61029, Urbino, Italy.
| | - Giorgio Famiglini
- LC-MS Lab, Department of Pure and Applied Sciences, University of Urbino Carlo Bo, Piazza Rinascimento 6, 61029, Urbino, Italy
| | - Nicole Marittimo
- LC-MS Lab, Department of Pure and Applied Sciences, University of Urbino Carlo Bo, Piazza Rinascimento 6, 61029, Urbino, Italy
| | - Marco Agostini
- Laboratorio di Tossicologia, A.S.T. AV1, Via Lombroso 15, 61122, Pesaro, Italy
| | - Caterina Renzoni
- Laboratorio di Tossicologia, A.S.T. AV1, Via Lombroso 15, 61122, Pesaro, Italy
| | - Pierangela Palma
- LC-MS Lab, Department of Pure and Applied Sciences, University of Urbino Carlo Bo, Piazza Rinascimento 6, 61029, Urbino, Italy
- Department of Chemistry, Vancouver Island University, B-360-R306, 900 Fifth St., Nanaimo, BC, Canada
| | - Achille Cappiello
- LC-MS Lab, Department of Pure and Applied Sciences, University of Urbino Carlo Bo, Piazza Rinascimento 6, 61029, Urbino, Italy
- Department of Chemistry, Vancouver Island University, B-360-R306, 900 Fifth St., Nanaimo, BC, Canada
| |
Collapse
|
15
|
Li C, Xiao J, Wu S, Liu L, Zeng X, Zhao Q, Zhang Z. Clinical application of serum-based proteomics technology in human tumor research. Anal Biochem 2023; 663:115031. [PMID: 36580994 DOI: 10.1016/j.ab.2022.115031] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Revised: 12/20/2022] [Accepted: 12/24/2022] [Indexed: 12/27/2022]
Abstract
The rapid development of proteomics technology in the past decades has led to further human understanding of tumor research, and in some ways, the technology plays a very important supporting role in the early detection of tumors. Human serum has been shown to contain a variety of proteins closely related to life activities, and the dynamic change in proteins can often reflect the physiological and pathological conditions of the body. Serum has the advantage of easy extraction, so the application of proteomics technology in serum has become a hot spot and frontier area for the study of malignant tumors. However, there are still many difficulties in the standardized use of proteomic technologies, which inevitably limit the clinical application of proteomic technologies due to the heterogeneity of human proteins leading to incomplete whole proteome populations, in addition to most serum protein markers being now not highly specific in aiding the early detection of tumors. Nevertheless, further development of proteomics technologies will greatly increase our understanding of tumor biology and help discover more new tumor biomarkers with specificity that will enable medical technology.
Collapse
Affiliation(s)
- Chen Li
- Department of Pathology, The First Affiliated Hospital of University of South China, Hunan, Hengyang, 421001, Hunan Province, China
| | - Juan Xiao
- Department of Otorhinolaryngology, The Second Affiliated Hospital of University of South China, Hunan, Hengyang, 421001, Hunan Province, China
| | - Shihua Wu
- Department of Pathology, The Second Hospital of Shaoyang College, Hunan, Shaoyang, 422000, Hunan Province, China
| | - Lu Liu
- Department of Pathology, The First Affiliated Hospital of University of South China, Hunan, Hengyang, 421001, Hunan Province, China
| | - Xuemei Zeng
- Cancer Research Institute of Hengyang Medical College, University of South China, Key Laboratory of Cancer Cellular and Molecular Pathology in Hunan Province, Hunan, Hengyang, 421001, China
| | - Qiang Zhao
- Department of Pathology, The First Affiliated Hospital of University of South China, Hunan, Hengyang, 421001, Hunan Province, China.
| | - Zhiwei Zhang
- Department of Pathology, The First Affiliated Hospital of University of South China, Hunan, Hengyang, 421001, Hunan Province, China; Cancer Research Institute of Hengyang Medical College, University of South China, Key Laboratory of Cancer Cellular and Molecular Pathology in Hunan Province, Hunan, Hengyang, 421001, China.
| |
Collapse
|
16
|
Methods and Advances in the Design, Testing and Development of In Vitro Diagnostic Instruments. Processes (Basel) 2023. [DOI: 10.3390/pr11020403] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
Abstract
With the continuous improvement of medical testing and instrumentation engineering technologies, the design, testing and development methods of in vitro diagnostic instruments are developing rapidly. In vitro diagnostic instruments are also gradually developing into a class of typical high-end medical equipment. The design of in vitro diagnostic instruments involves a variety of medical diagnostic methods and biochemical, physical and other related technologies, and its development process involves complex system engineering. This paper systematically organizes and summarizes the design, testing and development methods of in vitro diagnostic instruments and their development in recent years, focusing on summarizing the related technologies and core aspects of the R&D process, and analyzes the development trend of the in vitro diagnostic instrument market.
Collapse
|
17
|
Balcázar-Zumaeta CR, Castro-Alayo EM, Cayo-Colca IS, Idrogo-Vásquez G, Muñoz-Astecker LD. Metabolomics during the spontaneous fermentation in cocoa (Theobroma cacao L.): An exploraty review. Food Res Int 2023; 163:112190. [PMID: 36596129 DOI: 10.1016/j.foodres.2022.112190] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Revised: 11/14/2022] [Accepted: 11/15/2022] [Indexed: 11/21/2022]
Abstract
Spontaneous fermentation is a process that depends on substrates' physical characteristics, crop variety, and postharvest practices; it induces variations in the metabolites that are responsible for the taste, aroma, and quality. Metabolomics makes it possible to detect key metabolites using chemometrics and makes it possible to establish patterns or identify biomarker behaviors under certain conditions at a given time. Therefore, sensitive and highly efficient analytical techniques allow for studying the metabolomic fingerprint changes during fermentation; which identify and quantify metabolites related to taste and aroma formation of an adequate processing time. This review shows that studying metabolomics in spontaneous fermentation permits the characterization of spontaneous fermentation in different stages. Also, it demonstrates the possibility of modulating the quality of cocoa by improving the spontaneous fermentation time (because of volatile aromatic compounds formation), thus standardizing the process to obtain attributes and quality that will later impact the chocolate quality.
Collapse
Affiliation(s)
- César R Balcázar-Zumaeta
- Instituto de Investigación, Innovación y Desarrollo para el Sector Agrario y Agroindustrial de la Región Amazonas (IIDAA), Facultad de Ingeniería y Ciencias Agrarias, Universidad Nacional Toribio Rodríguez de Mendoza de Amazonas, Calle Higos Urco 342-350-356, Chachapoyas, Amazonas, Peru.
| | - Efraín M Castro-Alayo
- Instituto de Investigación, Innovación y Desarrollo para el Sector Agrario y Agroindustrial de la Región Amazonas (IIDAA), Facultad de Ingeniería y Ciencias Agrarias, Universidad Nacional Toribio Rodríguez de Mendoza de Amazonas, Calle Higos Urco 342-350-356, Chachapoyas, Amazonas, Peru.
| | - Ilse S Cayo-Colca
- Facultad de Ingeniería Zootecnista, Agronegocios y Biotecnología, Universidad Nacional Toribio Rodríguez de Mendoza de Amazonas, Calle Higos Urco 342-350-356, Chachapoyas, Amazonas, Peru.
| | - Guillermo Idrogo-Vásquez
- Instituto de Investigación, Innovación y Desarrollo para el Sector Agrario y Agroindustrial de la Región Amazonas (IIDAA), Facultad de Ingeniería y Ciencias Agrarias, Universidad Nacional Toribio Rodríguez de Mendoza de Amazonas, Calle Higos Urco 342-350-356, Chachapoyas, Amazonas, Peru.
| | - Lucas D Muñoz-Astecker
- Instituto de Investigación, Innovación y Desarrollo para el Sector Agrario y Agroindustrial de la Región Amazonas (IIDAA), Facultad de Ingeniería y Ciencias Agrarias, Universidad Nacional Toribio Rodríguez de Mendoza de Amazonas, Calle Higos Urco 342-350-356, Chachapoyas, Amazonas, Peru.
| |
Collapse
|
18
|
Guerrero-Esperanza M, Wrobel K, Wrobel K, Ordaz-Ortiz JJ. Determination of fatty acids in vegetable oils by GC-MS, using multiple-ion quantification (MIQ). J Food Compost Anal 2023. [DOI: 10.1016/j.jfca.2022.104963] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
19
|
Derivatization Strategies in Flavor Analysis: An Overview over the Wine and Beer Scenario. CHEMISTRY 2022. [DOI: 10.3390/chemistry4040109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
Wine and beer are the most appreciated and consumed beverages in the world. This success is mainly due to their characteristic taste, smell, and aroma, which can delight consumer’s palates. These olfactory characteristics are produced from specific classes of volatile compounds called “volatile odor-active compounds” linked to different factors such as age and production. Given the vast market of drinking beverages, the characterization of these odor compounds is increasingly important. However, the chemical complexity of these beverages has led the scientific community to develop several analytical techniques for extracting and quantifying these molecules. Even though the recent “green-oriented” trend is directed towards direct preparation-free procedures, for some class of analytes a conventional step like derivatization is unavoidable. This review is a snapshot of the most used derivatization strategies developed in the last 15 years for VOAs’ determination in wine and beer, the most consumed fermented beverages worldwide and among the most complex ones. A comprehensive overview is provided for every method, whereas pros and cons are critically analyzed and discussed. Emphasis was given to miniaturized methods which are more consistent with the principles of “green analytical chemistry”.
Collapse
|
20
|
Mass spectrometry for breath analysis. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116823] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
21
|
Enhanced microfluidic open interface for the direct coupling of solid phase microextraction with liquid electron ionization-tandem mass spectrometry. J Chromatogr A 2022; 1681:463479. [PMID: 36108353 DOI: 10.1016/j.chroma.2022.463479] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 09/01/2022] [Accepted: 09/04/2022] [Indexed: 11/21/2022]
Abstract
Solid-phase microextraction (SPME) directly coupled to MS is a widespread technique for determining small molecules in different matrices in many application fields. Here we present a modified microfluidic open interface (MOI) connected to a passive-flow-splitter device (PFS) for the direct coupling of SPME to a liquid-electron ionization (LEI) interface in a tandem mass spectrometer for the analysis of complex biological samples. No chromatographic separation is involved. The new MOI-PFS configuration was designed to speed up the sample transfer to MS, improving the signal-to-noise ratio and peak shape and leading to fast and sensitive results. MOI-PFS-LEI-MS/MS experiments were conducted using fentanyl as a model compound in water and blood serum. The method uses a C18 Bio-SPME fiber by direct immersion (3 min) in 300 µL of the sample followed by rapid desorption (1 min) in a flow isolated volume (MOI chamber, 2.5 µL) filled with 100% acetonitrile. The PFS permits the rapid transfer of a fraction of the sample into the MS via the LEI interface. The optimal conditions were obtained at a flow rate of 10 µL·min-1 and a 1:20 split ratio. Altogether, extraction, desorption, and analysis require approximately 5 min. Good interday and intraday precision, excellent linearity and LOQs in the µg·L-1 range were obtained for fentanyl in water and serum. Greenness evaluation demonstrated a limited environmental impact of this technique.
Collapse
|
22
|
Vargas Medina DA, Pereira dos Santos NG, Maciel EVS, Lanças FM. Current prospects on nano liquid chromatography coupled to electron ionization mass spectrometry (nanoLC-EI-MS). J LIQ CHROMATOGR R T 2022. [DOI: 10.1080/10826076.2022.2110114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
|
23
|
Cai X, Dai X, Li Z, Chen J, Wang X, Zhang M. An UPLC-MS/MS method for quantification of spiraeoside in mouse blood and its application to a pharmacokinetic and bioavailability study. ACTA CHROMATOGR 2022. [DOI: 10.1556/1326.2022.01061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Abstract
A simple, rapid, and sensitive method based on UPLC-MS/MS was developed to determine spiraeoside in mouse blood, and was applied to the pharmacokinetics and bioavailability of spiraeoside after mice after intravenous (a dose of 5 mg kg−1) and oral (a dose of 20 mg kg−1) administration. On HSS T3 column set at 40 °C, chromatographic separation was obtained with the mobile phase of acetonitrile and 0.1% formic acid using the gradient elution. Spiraeoside and internal standard (IS) were quantitatively analyzed using multiple reaction monitoring (MRM) mode in electrospray (ESI) positive interface. The MRM mode was monitoring the fragmentation of m/z 465.4→303.1 and m/z 451.3→ 289.2 for spironoside and IS, respectively. The results showed a good linear relationship was in the concentration range of 1–200 ng mL−1 (r > 0.998) and the lower limit of quantification (LLOQ) was 1.0 ng mL−1. The intra- and the inter-day precision (RSD%) of the method was within 14.0%, and the accuracy ranged from 90.0% to 115.0%. The extraction recovery of spriaeoside was better than 63.0%, and the matrix effects were in the range of 86%–98%. It also showed the half-life was short, and the absolute bioavailability was 4.0% in mice. Therefore, the established UPLC-MS/MS method was suitable for the pharmacokinetic and bioavailability study of spiraeoside in mice.
Collapse
Affiliation(s)
- Xiaojun Cai
- School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou, China
| | - Xiangyi Dai
- School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou, China
| | - Zhou Li
- Wenzhou Customs Comprehensive Technical Service Center, Wenzhou, China
| | - Junying Chen
- School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou, China
| | - Xianqin Wang
- School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou, China
| | - Meiling Zhang
- School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou, China
| |
Collapse
|
24
|
Maciel EVS, Pereira dos Santos NG, Vargas Medina DA, Lanças FM. Electron ionization mass spectrometry: Quo vadis? Electrophoresis 2022; 43:1587-1600. [DOI: 10.1002/elps.202100392] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Revised: 04/05/2022] [Accepted: 04/27/2022] [Indexed: 11/10/2022]
Affiliation(s)
| | | | | | - Fernando Mauro Lanças
- Institute of Chemistry of São Carlos University of São Paulo São Carlos São Paulo Brazil
| |
Collapse
|
25
|
Wang L, Zhang W, Shao Y, Zhang D, Guo G, Wang X. Analytical methods for obtaining binding parameters of drug–protein interactions: A review. Anal Chim Acta 2022; 1219:340012. [DOI: 10.1016/j.aca.2022.340012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Revised: 05/25/2022] [Accepted: 05/27/2022] [Indexed: 11/30/2022]
|
26
|
Advancement of omics techniques for chemical profile analysis and authentication of milk. Trends Food Sci Technol 2022. [DOI: 10.1016/j.tifs.2022.06.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
27
|
Langford JB, Lurie IS. Use of micro, capillary, and nano liquid chromatography for forensic analysis. J Sep Sci 2021; 45:38-50. [PMID: 34626162 DOI: 10.1002/jssc.202100631] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2021] [Revised: 09/28/2021] [Accepted: 09/29/2021] [Indexed: 01/03/2023]
Abstract
The use of micro, capillary, and nano liquid chromatography systems for forensic analysis has excellent potential. In a field where sample size is often limited, several studies have presented the viability of capillary columns with microflow and nanoflow, and when using mass spectrometric analysis limits of detection can be improved. Reduction in flow rates result in significant reduction in operating costs. Recent advances in miniaturized liquid chromatography systems also aim at in-laboratory and on-site detection, which have already been applied to forensic drug cases. This critical review will discuss the advantages, disadvantages, and applicability of microflow and nano liquid chromatography. In this regard, included in this article is a discussion of some promising areas not yet applied to forensic research.
Collapse
Affiliation(s)
- Joel B Langford
- Department of Forensic Science, The George Washington University, Washington, DC, 20007, USA
| | - Ira S Lurie
- Department of Forensic Science, The George Washington University, Washington, DC, 20007, USA
| |
Collapse
|