1
|
Belhameid A, Casado-Carmona FA, Megriche A, López-Lorente ÁI, Lucena R, Cárdenas S. On-site extraction of benzophenones from swimming pool water using hybrid tapes based on the integration of hydrophilic-lipophilic balance microparticles and an outer magnetic nanometric domain. Mikrochim Acta 2024; 191:513. [PMID: 39105990 PMCID: PMC11303577 DOI: 10.1007/s00604-024-06586-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2024] [Accepted: 07/22/2024] [Indexed: 08/07/2024]
Abstract
An on-site extraction device is presented consisting of scotch tape modified with concentric domains of micrometric hydrophilic-lipophilic balance (HLB) particles surrounded by a ring of nanometric magnetic ones. On the one hand, HLB microparticles are readily available at the surface of the tape, exposed to interact with the target analytes, being responsible for the extraction capacity of the sorptive phase. On the other hand, the presence of magnetic nanoparticles enables the attachment of the modified tape onto a metallic screw via a magnet, which is then coupled to a wireless drill, enabling the stirring of the microextraction device. Both are simply fixed to the cost-effective, flexible, and versatile support, i.e., scotch tape, owing to their adhesive properties. The microextraction device has been applied to the determination of six benzophenones in swimming pool water samples. The variables that may affect the extraction process have been evaluated. Under the optimum conditions and using liquid chromatography-tandem mass spectrometry as the instrumental technique, the method provided a limit of detection of 0.03 µg L-1. The intra-day precision, evaluated at three different concentration levels and expressed as relative standard deviation, was lower than 10%, which also comprises the variability within single-use sorptive tapes. The accuracy, calculated with spiked samples and expressed as relative recovery, ranged from 71 to 138%. The method was applied to the analysis of swimming pool water, revealing the presence of such compounds.
Collapse
Affiliation(s)
- Ahmed Belhameid
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain
- Laboratory of Applied Mineral Chemistry, Faculty of Sciences of Tunis, University of Tunis El Manar, University, Campus El Manar 1, 2092, Tunis, Tunisia
| | - Francisco Antonio Casado-Carmona
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain
- FI-TRACE Group, Department of Chemistry, Faculty of Science, University of the Balearic Islands, Illes Balears, Carretera de Valldemossa Km 7.5, E-07122, Palma de Mallorca, Spain
| | - Adel Megriche
- Laboratory of Applied Mineral Chemistry, Faculty of Sciences of Tunis, University of Tunis El Manar, University, Campus El Manar 1, 2092, Tunis, Tunisia
| | - Ángela Inmaculada López-Lorente
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain.
| | - Rafael Lucena
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain.
| | - Soledad Cárdenas
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain
| |
Collapse
|
2
|
Barzallo D, Están A, Crespí N, Palomino C, Turnes G, Palacio E, Ferrer L. On-site extraction using a 3D printed device coated with Zn/Co-ZIF-derived carbon followed by an on-line SIA-HPLC-FL system for fluoroquinolones determination in wastewater. Talanta 2024; 273:125897. [PMID: 38484500 DOI: 10.1016/j.talanta.2024.125897] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Revised: 02/21/2024] [Accepted: 03/07/2024] [Indexed: 04/09/2024]
Abstract
A 3D printed device covered with Zn/Co-ZIF-derived carbon allows the on-site extraction of fluoroquinolones (FQs) from wastewater, avoiding the sample transportation to the laboratory, and the subsequent elution, separation and determination using an on-line flow system based on sequential injection analysis (SIA) coupled to HPLC-FL. Several parameters that affect the extraction efficiency and desorption were optimized including the sorption phase immobilization technique on the 3D device, extraction time, pH effect, sample volume as well as the type of eluent, eluent volume, and flow rate. Under optimum conditions, detection limits of 3-9 ng L-1 were achieved for norfloxacin, ciprofloxacin, danofloxacin, enrofloxacin and difloxacin. The precision expressed as relative standard deviation (%RSD, n = 3), showed intraday and interday ranges of 1.5-5.3% and 2.8-5.7%, respectively, demonstrating a good precision of the proposed methodology. To assess matrix effects and accuracy of the proposed method in real samples, recovery studies were performed without and with FQs spiked at different concentrations (0.5-10 μg L-1) to wastewater samples, showing good recoveries in the range of 91-104%. The results allow to confirm the applicability of MOF-derived carbons as adsorbents for on-site extraction, and the satisfactory separation and quantification of FQs by a SIA-HPLC-FL on-line system after their desorption with small eluent volumes.
Collapse
Affiliation(s)
- D Barzallo
- Environmental Analytical Chemistry Group, University of Balearic Islands, 07122, Palma de Mallorca, Spain
| | - A Están
- Materials Chemistry Group, University of Balearic Islands, 07122, Palma de Mallorca, Spain
| | - N Crespí
- Materials Chemistry Group, University of Balearic Islands, 07122, Palma de Mallorca, Spain
| | - C Palomino
- Materials Chemistry Group, University of Balearic Islands, 07122, Palma de Mallorca, Spain
| | - G Turnes
- Materials Chemistry Group, University of Balearic Islands, 07122, Palma de Mallorca, Spain
| | - E Palacio
- Environmental Analytical Chemistry Group, University of Balearic Islands, 07122, Palma de Mallorca, Spain
| | - L Ferrer
- Environmental Analytical Chemistry Group, University of Balearic Islands, 07122, Palma de Mallorca, Spain.
| |
Collapse
|
3
|
Calero-Cañuelo C, Casado-Carmona FA, Lucena R, Cárdenas S. Sorptive tape-spray tandem mass spectrometry using aluminum foil coated with mixed-mode microparticles. Talanta 2024; 272:125774. [PMID: 38359721 DOI: 10.1016/j.talanta.2024.125774] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Revised: 02/06/2024] [Accepted: 02/07/2024] [Indexed: 02/17/2024]
Abstract
Direct mass spectrometry (MS) is an exciting strategy in bioanalysis, enabling rapid decision-making in different scenarios. Its application is usually hindered by matrix effects and the typically low concentration of the target compounds in the biofluids. In this sense, combining a previous sample preparation step minimizes or removes these shortcomings. This article describes sorptive tape-spray tandem mass spectrometry (STS-MS/MS) based on mixed-mode particles as a strategy to combine sample preparation and MS analysis in a single device. The technique uses a sorptive tape (ST) consisting of mixed-mode polymeric microparticles (combining ionic exchange and hydrophobic interactions) coated over aluminum foil in a spatial controlled way. The tapes act as the sorptive phases to isolate the analytes from the sample matrix and substrates for STS-MS/MS. The performance of the technique has been evaluated by developing a method to determine codeine in saliva as proof of concept. The affordability of the STs elements allows the preparation of many individual phases at low cost so that several samples can be extracted simultaneously, thus increasing the sample throughput. The extraction variables were optimized following a multivariate approach. Working under the optimum conditions, the limit of detection was 0.3 μg L-1, while the intraday precision, calculated as relative standard deviation (RSD) at three concentration levels, was better than 9.4 %. The accuracy, expressed as relative recovery, was in the range of 78-98 %. The method was also applied to the analysis of real samples. Despite being a powerful strategy, the direct combination of microextraction to MS is not always affordable in all laboratories. For this reason, the STs were also combined with commercial liquid chromatography-MS working under the direct infusion mode to demonstrate the usefulness of the ST in classical extraction workflows.
Collapse
Affiliation(s)
- Carlos Calero-Cañuelo
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain
| | - Francisco Antonio Casado-Carmona
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain; FI-TRACE Group, Department of Chemistry, Faculty of Science, University of the Balearic Islands, Carretera de Valldemossa Km 7.5, E-07122, Palma de Mallorca, Illes Balears, Spain
| | - Rafael Lucena
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain.
| | - Soledad Cárdenas
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain
| |
Collapse
|
4
|
Yıldız E, Çabuk H. In-syringe homogeneous liquid-phase microextraction followed by filtration-based phase separation for on-site extraction of chloroanilines from water samples. J Sep Sci 2024; 47:e2400124. [PMID: 38772717 DOI: 10.1002/jssc.202400124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2024] [Revised: 03/24/2024] [Accepted: 03/28/2024] [Indexed: 05/23/2024]
Abstract
This study introduces a new in-syringe homogeneous liquid-phase microextraction method for the rapid on-site extraction of chloroanilines from water samples. Extraction was performed using a plastic syringe, eliminating the use of any electrical power source. Di-(2-ethylhexyl) phosphoric acid (DEHPA) served as the extractant. The process initially involved dissolving DEHPA in an alkaline solution to obtain a homogeneous solution. Subsequently, the sodium salt of DEHPA was precipitated by salting-out, and the resulting heterogeneous mixture was filtered using a syringe filter. The precipitate containing the analytes was then dissolved in methanol for analysis by high-performance liquid chromatography. Under optimal conditions, extraction recovery for chloroanilines ranged from 26% to 71%. Method linearity was evaluated within a concentration range of 1.0-100 µg/L, resulting in coefficients of determination exceeding 0.9987 for all analytes. Method detection limits ranged from 0.28 to 0.41 µg/L. Intra and inter-day precision values were below 9.5% and 10.8%, respectively. The developed method was applied to determine chloroanilines in real waters, yielding acceptable recoveries ranging from 80% to 109% for spiked tap, rain, and stream waters. Additionally, the method was successfully employed for on-site extraction of target contaminants, demonstrating no statistically significant differences compared to laboratory results.
Collapse
Affiliation(s)
- Elif Yıldız
- Zonguldak Bülent Ecevit University, Faculty of Sciences, Department of Chemistry, Zonguldak, Türkiye
| | - Hasan Çabuk
- Zonguldak Bülent Ecevit University, Faculty of Sciences, Department of Chemistry, Zonguldak, Türkiye
| |
Collapse
|
5
|
Calero-Cañuelo C, Casado-Carmona FA, Lucena R, Cárdenas S. Mixed-mode cationic exchange sorptive tapes combined with direct infusion mass spectrometry for determining opioids in saliva samples. J Chromatogr A 2023; 1702:464097. [PMID: 37244164 DOI: 10.1016/j.chroma.2023.464097] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2023] [Revised: 05/11/2023] [Accepted: 05/22/2023] [Indexed: 05/29/2023]
Abstract
This article describes the synthesis of mixed-mode cationic exchange (MCX) tapes as sorptive phases in bioanalysis, and it faces the determination of methadone and tramadol in saliva as the model analytical problem. The tapes are synthesized using aluminum foil as substrate, which is subsequently covered with double-sided adhesive tape where the MCX particles (ca. 1.4 ± 0.2 mg) finally adhere. MCX particles allow the extraction of the analytes at the physiological pH, where both drugs are positively charged, minimizing the potential co-extraction of endogenous matrix compounds. The extraction conditions were studied considering the main variables (e.g. ionic strength, extraction time, sample dilution). Under the optimum conditions and using direct infusion mass spectrometry as the instrumental technique, detection limits as low as 3.3 μg·L-1 were obtained. The precision calculated at three different levels, and expressed as relative standard deviation, was better than 3.8%. The accuracy, expressed as relative recoveries, ranged from 83 to 113%. The method was finally applied to determine tramadol in saliva samples from patients under medical treatment. This approach opens the door to easily preparing sorptive tapes based on commercial (or ad-hoc synthesized) sorbent particles.
Collapse
Affiliation(s)
- Carlos Calero-Cañuelo
- Affordable and Sustainable Sample Preparation (AS2P) research group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain
| | - Francisco Antonio Casado-Carmona
- Affordable and Sustainable Sample Preparation (AS2P) research group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain
| | - Rafael Lucena
- Affordable and Sustainable Sample Preparation (AS2P) research group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain.
| | - Soledad Cárdenas
- Affordable and Sustainable Sample Preparation (AS2P) research group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain.
| |
Collapse
|
6
|
Wang H, Wang T, Hong M, Wang Z, Jin X, Wu H. Direct solidification of switchable-hydrophilicity salicylic acid: A design for the on-site dispersive liquid-liquid microextraction of benzoylurea insecticides in water and honey samples. J Chromatogr A 2023; 1688:463710. [PMID: 36528904 DOI: 10.1016/j.chroma.2022.463710] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Revised: 12/03/2022] [Accepted: 12/09/2022] [Indexed: 12/13/2022]
Abstract
This study describes the development of a fully manual method for on-site dispersive liquid-liquid microextraction based on the direct solidification of switchable-hydrophilicity salicylic acid (on-site DLLME-DSSA) coupled with high-performance liquid chromatography with an ultraviolet detector (HPLC-UVD) and its utilization for the detection of benzoylurea insecticides (BUs) in water and honey samples. Salicylic acid (SA), a switchable hydrophilic aromatic acid, was used as an extraction solvent. It can be converted into the hydrophobic/hydrophilic forms in pH-changeable solutions, facilitating facile and effective dispersion and phase separation. Moreover, the melting point of SA (significantly higher than room temperature) enables its direct solidification without an ice-water bath, facilitating its collection by filtration. The dispersion, separation, and collection of the extraction solvent were carried out entirely in a plastic syringe without requiring special apparatus or additional energy. Univariate and response surface analyses were used to optimize various parameters of the on-site DLLME-DSSA method. Under optimal conditions, the limits of determination (LODs) were 1.50 µg L-1 and 0.03-0.09 mg kg-1 in water and honey, respectively. The relative standard deviations (RSDs) for inter-day (n = 5) and intra-day (n = 5) precision were ≤8.4%, whereas the extraction recoveries and enrichment factors for the BUs ranged from 67.0 to 97.1% and 29 to 34, respectively. Furthermore, the proposed method was used for the on-site extraction and laboratory detection of BUs from real water and honey samples. Theoretical analyses indicated non-covalent interactions (such as hydrogen bonds, electrostatic interactions, van der Waals forces, and π-π interactions) to be the main driving force for extraction. This study introduces a switchable hydrophilic aromatic acid capable of direct solidification into on-site DLLME for the first time, opening new frontiers in the development of on-site sample pretreatment methods.
Collapse
Affiliation(s)
- Huazi Wang
- School of Chemistry and Materials Engineering, Fuyang Normal University, Fuyang, Anhui 236037, PR China; Anhui Provincial Technology and Engineering Research Centre for Biomass Conversion and Pollution Prevention and Control, Fuyang, Anhui 236037, PR China
| | - Tiantian Wang
- School of Chemistry and Materials Engineering, Fuyang Normal University, Fuyang, Anhui 236037, PR China
| | - MingXiu Hong
- School of Chemistry and Materials Engineering, Fuyang Normal University, Fuyang, Anhui 236037, PR China
| | - Ziyang Wang
- School of Chemistry and Materials Engineering, Fuyang Normal University, Fuyang, Anhui 236037, PR China
| | - Xiaoyan Jin
- School of Chemistry and Materials Engineering, Fuyang Normal University, Fuyang, Anhui 236037, PR China.
| | - Hai Wu
- School of Chemistry and Materials Engineering, Fuyang Normal University, Fuyang, Anhui 236037, PR China; Anhui Province Key Laboratory of Environmental Hormone and Reproduction, Fuyang, Anhui 236037, PR China.
| |
Collapse
|
7
|
Vállez-Gomis V, Carchano-Olcina S, Benedé JL, Chisvert A, Salvador A. Entrapment of magnetic nanoparticles into poly(divinylbenzene-co-N-vinylpyrrolidone) copolymer for the determination of prohibited and restricted fragrance ingredients in cosmetic products. Microchem J 2022. [DOI: 10.1016/j.microc.2022.108044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
8
|
Greener bioanalytical sample preparation. What is next? Bioanalysis 2022; 14:1021-1023. [DOI: 10.4155/bio-2022-0118] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|