1
|
Seesaard T, Kamjornkittikoon K, Wongchoosuk C. A comprehensive review on advancements in sensors for air pollution applications. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 951:175696. [PMID: 39197792 DOI: 10.1016/j.scitotenv.2024.175696] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/22/2024] [Revised: 08/18/2024] [Accepted: 08/20/2024] [Indexed: 09/01/2024]
Abstract
Air pollution, originating from both natural and human-made sources, presents significant threats to human health and the environment. This review explores the latest technological advancements in air quality sensors focusing on their applications in monitoring a wide range of pollution sources from volcanic eruptions and wildfires to industrial emissions, transportation, agricultural activities and indoor air quality. The review categorizes these sources and examines the operational principles, system architectures, and effectiveness of various air quality monitoring instruments including low-cost sensors, gas analyzers, weather stations, passive sampling devices and remote sensing technologies such as satellite and LiDAR. Key insights include the rapid evolution of sensor technology driven by the need for more accurate, real-time monitoring solutions that are both cost-effective and widely accessible. Despite significant advancements, challenges such as sensor calibration, standardization, and data integration remain critical for ensuring reliable air quality assessments. The manuscript concludes by emphasizing the need for continued innovation and the integration of advanced sensor technologies with regulatory frameworks to enhance environmental management and public health protection.
Collapse
Affiliation(s)
- Thara Seesaard
- Department of Physics, Faculty of Science and Technology, Kanchanaburi Rajabhat University, Kanchanaburi 71190, Thailand
| | - Kamonrat Kamjornkittikoon
- Department of Mathematics and Statistics, Faculty of Science and Technology, Kanchanaburi Rajabhat University, Kanchanaburi 71190, Thailand
| | - Chatchawal Wongchoosuk
- Department of Physics, Faculty of Science, Kasetsart University, Bangkok 10900, Thailand.
| |
Collapse
|
2
|
Kongkaew S, Janduang S, Srilikhit A, Kaewnu K, Thipwimonmas Y, Cotchim S, Torrarit K, Phua CH, Limbut W. Waste DVD polycarbonate substrate for screen-printed carbon electrode modified with PVP-stabilized AuNPs for continuous free chlorine detection. Talanta 2024; 277:126406. [PMID: 38901193 DOI: 10.1016/j.talanta.2024.126406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Revised: 06/07/2024] [Accepted: 06/09/2024] [Indexed: 06/22/2024]
Abstract
An electrochemical free chlorine sensor was developed by modifying a lab-made screen-printed carbon electrode (SPCE) with gold nanoparticles synthesized with polyvinylpyrrolidone (AuNPs-PVP). The electrode was made by screen printing carbon ink on a waste digital versatile disc (SPC-wDVD). PVP was used to stabilize AuNPs. Scanning electron microscopy showed that AuNPs aggregated without the stabilizer. The electrochemical behavior of the SPC-wDVD was evaluated by comparison with commercial SPCEs from two companies. Electrochemical characterization involved cyclic voltammetry and electrochemical impedance spectroscopy. The detection of free chlorine in water samples was continuous, facilitated by a flow-injection system. In the best condition, the developed sensor exhibited linearity from 0.25 to 3.0 and 3.0 to 500 mg L-1. The limit of detection was 0.1 mg L-1. The stability of the sensor enabled the detection of free chlorine at least 475 times with an RSD of 3.2 %. The AuNPs-PVP/SPC-wDVD was able to detect free chlorine in drinking water, tap water and swimming pool water. The agreement between the results obtained with the proposed method and the standard spectrophotometric method confirmed the precision of the developed sensor.
Collapse
Affiliation(s)
- Supatinee Kongkaew
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Santipap Janduang
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Angkana Srilikhit
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Krittapas Kaewnu
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Yudtapum Thipwimonmas
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Suparat Cotchim
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Kamonchanok Torrarit
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Cheng Ho Phua
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Warakorn Limbut
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Forensic Science Innovation and Service Center, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand.
| |
Collapse
|
3
|
Patella B, Di Vincenzo S, Moukri N, Bonafede F, Ferraro M, Lazzara V, Giuffrè MR, Carbone S, Aiello G, Russo M, Cipollina C, Inguanta R, Pace E. Gold nanowires-based sensor for quantification of H 2O 2 released by human airway epithelial cells. Talanta 2024; 272:125772. [PMID: 38367400 DOI: 10.1016/j.talanta.2024.125772] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 01/08/2024] [Accepted: 02/07/2024] [Indexed: 02/19/2024]
Abstract
Hydrogen peroxide (H2O2) is a biomarker relevant for oxidative stress monitoring. Most chronic airway diseases are characterized by increased oxidative stress. To date, the main methods for the detection of this analyte are expensive and time-consuming laboratory techniques such as fluorometric and colorimetric assays. There is a growing interest in the development of electrochemical sensors for H2O2 detection due to their low cost, ease of use, sensitivity and rapid response. In this work, an electrochemical sensor based on gold nanowire arrays has been developed. Thanks to the catalytic activity of gold against hydrogen peroxide reduction and the high surface area of nanowires, this sensor allows the quantification of this analyte in a fast, efficient and selective way. The sensor was obtained by template electrodeposition and consists of gold nanowires about 5 μm high and with an average diameter of about 200 nm. The high active surface area of this electrode, about 7 times larger than a planar gold electrode, ensured a high sensitivity of the sensor (0.98 μA μM-1cm-2). The sensor allows the quantification of hydrogen peroxide in the range from 10 μM to 10 mM with a limit of detection of 3.2 μM. The sensor has excellent properties in terms of reproducibility, repeatability and selectivity. The sensor was validated by quantifying the hydrogen peroxide released by human airways A549 cells exposed or not to the pro-oxidant compound rotenone. The obtained results were validated by comparing them with those obtained by flow cytometry after staining the cells with the fluorescent superoxide-sensitive Mitosox Red probe giving a very good concordance.
Collapse
Affiliation(s)
- Bernardo Patella
- Department of Engineering, University of Palermo, Palermo, 90128, Italy
| | - Serena Di Vincenzo
- Institute of Translational Pharmacology (IFT), National Research Council of Italy (CNR), Palermo, 90146, Italy
| | - Nadia Moukri
- Department of Engineering, University of Palermo, Palermo, 90128, Italy
| | | | - Maria Ferraro
- Institute of Translational Pharmacology (IFT), National Research Council of Italy (CNR), Palermo, 90146, Italy
| | - Valentina Lazzara
- Department of Health Promotion Sciences, Maternal and Infant Care, Internal Medicine and Medical Specialties (PROMISE), University of Palermo, Palermo, 90127, Italy
| | | | - Sonia Carbone
- Department of Engineering, University of Palermo, Palermo, 90128, Italy
| | - Giuseppe Aiello
- Department of Engineering, University of Palermo, Palermo, 90128, Italy
| | | | - Chiara Cipollina
- Institute of Translational Pharmacology (IFT), National Research Council of Italy (CNR), Palermo, 90146, Italy; Ri.MED Foundation, Palermo, 90146, Italy
| | - Rosalinda Inguanta
- Department of Engineering, University of Palermo, Palermo, 90128, Italy; Institute of Translational Pharmacology (IFT), National Research Council of Italy (CNR), Palermo, 90146, Italy.
| | - Elisabetta Pace
- Institute of Translational Pharmacology (IFT), National Research Council of Italy (CNR), Palermo, 90146, Italy
| |
Collapse
|
4
|
Malecka-Baturo K, Daniels M, Dehaen W, Radecka H, Radecki J, Grabowska I. Voltammetric Sensing of Chloride Based on a Redox-Active Complex: A Terpyridine-Co(II)-Dipyrromethene Functionalized Anion Receptor Deposited on a Gold Electrode. Molecules 2024; 29:2102. [PMID: 38731593 PMCID: PMC11085611 DOI: 10.3390/molecules29092102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2024] [Revised: 04/16/2024] [Accepted: 04/29/2024] [Indexed: 05/13/2024] Open
Abstract
A redox-active complex containing Co(II) connected to a terpyridine (TPY) and dipyrromethene functionalized anion receptor (DPM-AR) was created on a gold electrode surface. This host-guest supramolecular system based on a redox-active layer was used for voltammetric detection of chloride anions in aqueous solutions. The sensing mechanism was based on the changes in the redox activity of the complex observed upon binding of the anion to the receptor. The electron transfer coefficient (α) and electron transfer rate constant (k0) for the modified gold electrodes were calculated based on Cyclic Voltammetry (CV) experiments results. On the other hand, the sensing abilities were examined using Square Wave Voltammetry (SWV). More importantly, the anion receptor was selective to chloride, resulting in the highest change in Co(II) current intensity and allowing to distinguish chloride, sulfate and bromide. The proposed system displayed the highest sensitivity to Cl- with a limit of detection of 0.50 fM. The order of selectivity was: Cl- > SO42- > Br-, which was confirmed by the binding constants (K) and reaction coupling efficiencies (RCE).
Collapse
Affiliation(s)
- Kamila Malecka-Baturo
- Institute of Animal Reproduction and Food Research, Polish Academy of Sciences, Tuwima Street 10, 10-748 Olsztyn, Poland; (K.M.-B.); (H.R.)
| | - Mathias Daniels
- Sustainable Chemistry for Metals and Molecules, Department of Chemistry, KU Leuven, Leuven Chem&Tech, Celestijnenlaan 200F, B-3001 Leuven, Belgium (W.D.)
| | - Wim Dehaen
- Sustainable Chemistry for Metals and Molecules, Department of Chemistry, KU Leuven, Leuven Chem&Tech, Celestijnenlaan 200F, B-3001 Leuven, Belgium (W.D.)
| | - Hanna Radecka
- Institute of Animal Reproduction and Food Research, Polish Academy of Sciences, Tuwima Street 10, 10-748 Olsztyn, Poland; (K.M.-B.); (H.R.)
| | - Jerzy Radecki
- Institute of Animal Reproduction and Food Research, Polish Academy of Sciences, Tuwima Street 10, 10-748 Olsztyn, Poland; (K.M.-B.); (H.R.)
| | - Iwona Grabowska
- Institute of Animal Reproduction and Food Research, Polish Academy of Sciences, Tuwima Street 10, 10-748 Olsztyn, Poland; (K.M.-B.); (H.R.)
| |
Collapse
|
5
|
La Mantia FP, Baiamonte M, Santangelo S, Scaffaro R, Mistretta MC. Influence of Different Environments and Temperatures on the Photo-Oxidation Behaviour of the Polypropylene. Polymers (Basel) 2022; 15:polym15010074. [PMID: 36616424 PMCID: PMC9823793 DOI: 10.3390/polym15010074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 12/20/2022] [Accepted: 12/22/2022] [Indexed: 12/28/2022] Open
Abstract
The photo-oxidation of polypropylene at two different temperatures and in three different environments-air, distilled water and sea water-has been followed as a function of the irradiation time. The photo-oxidation kinetic is dramatically dependent on the amount of oxygen available for the oxidation reactions and on the temperature. While the photo-oxidation is very fast in air, the degradation is much slower in the two aqueous media. The degradation in sea water is slightly slower than in distilled water. In all cases, the degradation kinetic increases remarkably with the temperature. This behavior has been attributed to the lower oxygen availability for the oxidation reactions of the polymers. The light difference of the degradation kinetic between the two aqueous media depends on the small difference of the oxygen concentration at the test temperatures of 40 and 70 °C. At the latter temperature, the difference between the degradation kinetic in distilled water and sea water is still less important because increasing the temperature decreases the solubility of the oxygen, and it tends to became very similar in both samples of water.
Collapse
Affiliation(s)
- Francesco Paolo La Mantia
- Department of Engineering, Università di Palermo, Viale delle Scienze, 90128 Palermo, Italy
- INSTM, Italian Consortium for Materials Science and Technology, Via Giusti 9, 50125 Firenze, Italy
- Correspondence:
| | - Marilena Baiamonte
- INSTM, Italian Consortium for Materials Science and Technology, Via Giusti 9, 50125 Firenze, Italy
| | - Stefania Santangelo
- INSTM, Italian Consortium for Materials Science and Technology, Via Giusti 9, 50125 Firenze, Italy
| | - Roberto Scaffaro
- Department of Engineering, Università di Palermo, Viale delle Scienze, 90128 Palermo, Italy
| | - Maria Chiara Mistretta
- Department of Engineering, Università di Palermo, Viale delle Scienze, 90128 Palermo, Italy
| |
Collapse
|
6
|
Patella B, Narayan T, O'Sullivan B, Daly R, Zanca C, Lovera P, Inguanta R, O'Riordan A. Simultaneous detection of copper and mercury in water samples using in-situ pH control with electrochemical stripping techniques. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2022.141668] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/04/2022]
|
7
|
Lopresti F, Patella B, Divita V, Zanca C, Botta L, Radacsi N, O’Riordan A, Aiello G, Kersaudy-Kerhoas M, Inguanta R, La Carrubba V. Green and Integrated Wearable Electrochemical Sensor for Chloride Detection in Sweat. SENSORS (BASEL, SWITZERLAND) 2022; 22:8223. [PMID: 36365929 PMCID: PMC9654961 DOI: 10.3390/s22218223] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Revised: 10/23/2022] [Accepted: 10/24/2022] [Indexed: 06/16/2023]
Abstract
Wearable sensors for sweat biomarkers can provide facile analyte capability and monitoring for several diseases. In this work, a green wearable sensor for sweat absorption and chloride sensing is presented. In order to produce a sustainable device, polylactic acid (PLA) was used for both the substrate and the sweat absorption pad fabrication. The sensor material for chloride detection consisted of silver-based reference, working, and counter electrodes obtained from upcycled compact discs. The PLA substrates were prepared by thermal bonding of PLA sheets obtained via a flat die extruder, prototyped in single functional layers via CO2 laser cutting, and bonded via hot-press. The effect of cold plasma treatment on the transparency and bonding strength of PLA sheets was investigated. The PLA membrane, to act as a sweat absorption pad, was directly deposited onto the membrane holder layer by means of an electrolyte-assisted electrospinning technique. The membrane adhesion capacity was investigated by indentation tests in both dry and wet modes. The integrated device made of PLA and silver-based electrodes was used to quantify chloride ions. The calibration tests revealed that the proposed sensor platform could quantify chloride ions in a sensitive and reproducible way. The chloride ions were also quantified in a real sweat sample collected from a healthy volunteer. Therefore, we demonstrated the feasibility of a green and integrated sweat sensor that can be applied directly on human skin to quantify chloride ions.
Collapse
Affiliation(s)
- Francesco Lopresti
- Department of Engineering, University of Palermo, RU INSTM of Palermo, Viale delle Scienze, 90128 Palermo, Italy
| | - Bernardo Patella
- Department of Engineering, University of Palermo, RU INSTM of Palermo, Viale delle Scienze, 90128 Palermo, Italy
| | - Vito Divita
- Department of Engineering, University of Palermo, RU INSTM of Palermo, Viale delle Scienze, 90128 Palermo, Italy
| | - Claudio Zanca
- Department of Engineering, University of Palermo, RU INSTM of Palermo, Viale delle Scienze, 90128 Palermo, Italy
| | - Luigi Botta
- Department of Engineering, University of Palermo, RU INSTM of Palermo, Viale delle Scienze, 90128 Palermo, Italy
| | - Norbert Radacsi
- School of Engineering, Institute for Materials and Processes, The University of Edinburgh, King’s Buildings, Robert Stevenson Road, Edinburgh EH9 3FB, UK
| | - Alan O’Riordan
- Nanotechnology Group, Tyndall National Institute, University College Cork, T12R5CP Cork, Ireland
| | - Giuseppe Aiello
- Department of Engineering, University of Palermo, RU INSTM of Palermo, Viale delle Scienze, 90128 Palermo, Italy
| | - Maïwenn Kersaudy-Kerhoas
- Institute of Biological Chemistry, Biophysics and Bioengineering, Heriot-Watt University, Edinburgh EH14 4AS, UK
| | - Rosalinda Inguanta
- Department of Engineering, University of Palermo, RU INSTM of Palermo, Viale delle Scienze, 90128 Palermo, Italy
| | - Vincenzo La Carrubba
- Department of Engineering, University of Palermo, RU INSTM of Palermo, Viale delle Scienze, 90128 Palermo, Italy
| |
Collapse
|
8
|
Patella B, Vincenzo SD, Zanca C, Bollaci L, Ferraro M, Giuffrè MR, Cipollina C, Bruno MG, Aiello G, Russo M, Inguanta R, Pace E. Electrochemical Quantification of H 2O 2 Released by Airway Cells Growing in Different Culture Media. MICROMACHINES 2022; 13:1762. [PMID: 36296115 PMCID: PMC9611932 DOI: 10.3390/mi13101762] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Revised: 10/11/2022] [Accepted: 10/12/2022] [Indexed: 05/30/2023]
Abstract
Quantification of oxidative stress is a challenging task that can help in monitoring chronic inflammatory respiratory airway diseases. Different studies can be found in the literature regarding the development of electrochemical sensors for H2O2 in cell culture medium to quantify oxidative stress. However, there are very limited data regarding the impact of the cell culture medium on the electrochemical quantification of H2O2. In this work, we studied the effect of different media (RPMI, MEM, DMEM, Ham's F12 and BEGM/DMEM) on the electrochemical quantification of H2O2. The used electrode is based on reduced graphene oxide (rGO) and gold nanoparticles (AuNPs) and was obtained by co-electrodeposition. To reduce the electrode fouling by the medium, the effect of dilution was investigated using diluted (50% v/v in PBS) and undiluted media. With the same aim, two electrochemical techniques were employed, chronoamperometry (CH) and linear scan voltammetry (LSV). The influence of different interfering species and the effect of the operating temperature of 37 °C were also studied in order to simulate the operation of the sensor in the culture plate. The LSV technique made the sensor adaptable to undiluted media because the test time is short, compared with the CH technique, reducing the electrode fouling. The long-term stability of the sensors was also evaluated by testing different storage conditions. By storing the electrode at 4 °C, the sensor performance was not reduced for up to 21 days. The sensors were validated measuring H2O2 released by two different human bronchial epithelial cell lines (A549, 16HBE) and human primary bronchial epithelial cells (PBEC) grown in RPMI, MEM and BEGM/DMEM media. To confirm the results obtained with the sensor, the release of reactive oxygen species was also evaluated with a standard flow cytometry technique. The results obtained with the two techniques were very similar. Thus, the LSV technique permits using the proposed sensor for an effective oxidative stress quantification in different culture media and without dilution.
Collapse
Affiliation(s)
- Bernardo Patella
- Department of Engineering, University of Palermo, 90128 Palermo, Italy
| | - Serena Di Vincenzo
- Institute of Traslational Pharmacology (IFT), National Research Council of Italy (CNR), 90146 Palermo, Italy
| | - Claudio Zanca
- Department of Engineering, University of Palermo, 90128 Palermo, Italy
| | - Luciano Bollaci
- Department of Engineering, University of Palermo, 90128 Palermo, Italy
| | - Maria Ferraro
- Institute of Traslational Pharmacology (IFT), National Research Council of Italy (CNR), 90146 Palermo, Italy
| | | | - Chiara Cipollina
- Institute of Traslational Pharmacology (IFT), National Research Council of Italy (CNR), 90146 Palermo, Italy
- Ri.MED Foundation, 90146 Palermo, Italy
| | | | - Giuseppe Aiello
- Department of Engineering, University of Palermo, 90128 Palermo, Italy
| | | | | | - Elisabetta Pace
- Institute of Traslational Pharmacology (IFT), National Research Council of Italy (CNR), 90146 Palermo, Italy
| |
Collapse
|
9
|
Detection of chlorinated organic pollutants with an integrated screen-printed electrochemical sensor based on a carbon nanocomposite derived from bread waste. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2022.141459] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
10
|
Duan W, Fernández-Sánchez C, Gich M. Upcycling Bread Waste into a Ag-Doped Carbon Material Applied to the Detection of Halogenated Compounds in Waters. ACS APPLIED MATERIALS & INTERFACES 2022; 14:40182-40190. [PMID: 35998366 PMCID: PMC9460431 DOI: 10.1021/acsami.2c08332] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Bread waste is a major part of food wastage which could be upcycled to produce functional materials, following the principles of the circular bioeconomy. This work shows that bread waste can be recycled and valorized to produce a composite conductive material with excellent properties for chemical sensor applications. Here, dry bread is impregnated with an aqueous solution of a silver precursor and pyrolyzed to produce a porous carbon matrix containing Ag nanoparticles with diameters ranging from 20 to 40 nm. These particles perform as catalytic redox centers for the electrochemical detection of halide ions (Cl-, Br-, and I-) and organohalide target molecules such as sucralose and trichloroacetic acid. A thorough analytical characterization is carried out to show the potential application of the developed material for the manufacturing of electrochemical sensor approaches. The material preparation is sustainable, low-cost, simple, and upscalable. These are ideal features for the large-scale manufacturing by screen-printing technologies of single-use electrochemical sensors for the rapid analysis of halogenated organic pollutants in waters.
Collapse
Affiliation(s)
- Wenchao Duan
- Institut
de Ciència de Materials de Barcelona, ICMAB (CSIC), Campus UAB, 08193 Bellaterra, Spain
- Institut
de Microelectrònica de Barcelona, IMB-CNM (CSIC), Campus UAB, 08193 Bellaterra, Spain
| | - César Fernández-Sánchez
- Institut
de Microelectrònica de Barcelona, IMB-CNM (CSIC), Campus UAB, 08193 Bellaterra, Spain
- CIBER
de Bioingeniería, Biomateriales y
Nanomedicina (CIBER-BBN), Jordi Girona 18-26, 08034 Barcelona, Spain
| | - Martí Gich
- Institut
de Ciència de Materials de Barcelona, ICMAB (CSIC), Campus UAB, 08193 Bellaterra, Spain
| |
Collapse
|
11
|
Zhai J, Luo B, Li A, Dong H, Jin X, Wang X. Unlocking All-Solid Ion Selective Electrodes: Prospects in Crop Detection. SENSORS (BASEL, SWITZERLAND) 2022; 22:5541. [PMID: 35898054 PMCID: PMC9331676 DOI: 10.3390/s22155541] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Revised: 07/20/2022] [Accepted: 07/21/2022] [Indexed: 06/15/2023]
Abstract
This paper reviews the development of all-solid-state ion-selective electrodes (ASSISEs) for agricultural crop detection. Both nutrient ions and heavy metal ions inside and outside the plant have a significant influence on crop growth. This review begins with the detection principle of ASSISEs. The second section introduces the key characteristics of ASSISE and demonstrates its feasibility in crop detection based on previous research. The third section considers the development of ASSISEs in the detection of corps internally and externally (e.g., crop nutrition, heavy metal pollution, soil salinization, N enrichment, and sensor miniaturization, etc.) and discusses the interference of the test environment. The suggestions and conclusions discussed in this paper may provide the foundation for additional research into ion detection for crops.
Collapse
Affiliation(s)
- Jiawei Zhai
- Research Center of Intelligent Equipment, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China; (J.Z.); (B.L.); (A.L.); (H.D.); (X.J.)
- College of Mechanical and Electrical Engineering, Fujian Agriculture and Forestry University, Fuzhou 350108, China
| | - Bin Luo
- Research Center of Intelligent Equipment, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China; (J.Z.); (B.L.); (A.L.); (H.D.); (X.J.)
| | - Aixue Li
- Research Center of Intelligent Equipment, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China; (J.Z.); (B.L.); (A.L.); (H.D.); (X.J.)
| | - Hongtu Dong
- Research Center of Intelligent Equipment, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China; (J.Z.); (B.L.); (A.L.); (H.D.); (X.J.)
| | - Xiaotong Jin
- Research Center of Intelligent Equipment, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China; (J.Z.); (B.L.); (A.L.); (H.D.); (X.J.)
| | - Xiaodong Wang
- Research Center of Intelligent Equipment, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China; (J.Z.); (B.L.); (A.L.); (H.D.); (X.J.)
| |
Collapse
|
12
|
Upcycling Compact Discs for Flexible and Stretchable Bioelectronic Applications. Nat Commun 2022; 13:3727. [PMID: 35764646 PMCID: PMC9240022 DOI: 10.1038/s41467-022-31338-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Accepted: 06/12/2022] [Indexed: 01/04/2023] Open
Abstract
Electronic waste is a global issue brought about by the short lifespan of electronics. Viable methods to relieve the inundated disposal system by repurposing the enormous amount of electronic waste remain elusive. Inspired by the need for sustainable solutions, this study resulted in a multifaceted approach to upcycling compact discs. The once-ubiquitous plates can be transformed into stretchable and flexible biosensors. Our experiments and advanced prototypes show that effective, innovative biosensors can be developed at a low-cost. An affordable craft-based mechanical cutter allows pre-determined patterns to be scored on the recycled metal, an essential first step for producing stretchable, wearable electronics. The active metal harvested from the compact discs was inert, cytocompatible, and capable of vital biopotential measurements. Additional studies examined the material’s resistive emittance, temperature sensing, real-time metabolite monitoring performance, and moisture-triggered transience. This sustainable approach for upcycling electronic waste provides an advantageous research-based waste stream that does not require cutting-edge microfabrication facilities, expensive materials, and high-caliber engineering skills. Electronic waste is a global issue brought about by the short lifespan of electronics. Here, the authors report a process to upcycle compact discs into flexible and stretchable bio-electronics.
Collapse
|
13
|
Patella B, Moukri N, Regalbuto G, Cipollina C, Pace E, Di Vincenzo S, Aiello G, O’Riordan A, Inguanta R. Electrochemical Synthesis of Zinc Oxide Nanostructures on Flexible Substrate and Application as an Electrochemical Immunoglobulin-G Immunosensor. MATERIALS (BASEL, SWITZERLAND) 2022; 15:713. [PMID: 35160668 PMCID: PMC8837124 DOI: 10.3390/ma15030713] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/26/2021] [Revised: 01/10/2022] [Accepted: 01/11/2022] [Indexed: 11/17/2022]
Abstract
Immunoglobulin G (IgG), a type of antibody, represents approximately 75% of serum antibodies in humans, and is the most common type of antibody found in blood circulation. Consequently, the development of simple, fast and reliable systems for IgG detection, which can be achieved using electrochemical sandwich-type immunosensors, is of considerable interest. In this study we have developed an immunosensor for human (H)-IgG using an inexpensive and very simple fabrication method based on ZnO nanorods (NRs) obtained through the electrodeposition of ZnO. The ZnO NRs were treated by electrodepositing a layer of reduced graphene oxide (rGO) to ensure an easy immobilization of the antibodies. On Indium Tin Oxide supported on Polyethylene Terephthalate/ZnO NRs/rGO substrate, the sandwich configuration of the immunosensor was built through different incubation steps, which were all optimized. The immunosensor is electrochemically active thanks to the presence of gold nanoparticles tagging the secondary antibody. The immunosensor was used to measure the current density of the hydrogen development reaction which is indirectly linked to the concentration of H-IgG. In this way the calibration curve was constructed obtaining a logarithmic linear range of 10-1000 ng/mL with a detection limit of few ng/mL and good sensitivity.
Collapse
Affiliation(s)
- Bernardo Patella
- Dipartimento di Ingegneria, Università degli Studi di Palermo, 90128 Palermo, Italy; (B.P.); (N.M.); (G.R.); (G.A.)
| | - Nadia Moukri
- Dipartimento di Ingegneria, Università degli Studi di Palermo, 90128 Palermo, Italy; (B.P.); (N.M.); (G.R.); (G.A.)
| | - Gaia Regalbuto
- Dipartimento di Ingegneria, Università degli Studi di Palermo, 90128 Palermo, Italy; (B.P.); (N.M.); (G.R.); (G.A.)
| | - Chiara Cipollina
- Fondazione Ri.MED, 90133 Palermo, Italy;
- Istituto per la Ricerca e l’Innovazione Biomedica (IRIB)-Consiglio Nazionale delle Ricerche, 90153 Palermo, Italy; (E.P.); (S.D.V.)
| | - Elisabetta Pace
- Istituto per la Ricerca e l’Innovazione Biomedica (IRIB)-Consiglio Nazionale delle Ricerche, 90153 Palermo, Italy; (E.P.); (S.D.V.)
| | - Serena Di Vincenzo
- Istituto per la Ricerca e l’Innovazione Biomedica (IRIB)-Consiglio Nazionale delle Ricerche, 90153 Palermo, Italy; (E.P.); (S.D.V.)
| | - Giuseppe Aiello
- Dipartimento di Ingegneria, Università degli Studi di Palermo, 90128 Palermo, Italy; (B.P.); (N.M.); (G.R.); (G.A.)
| | - Alan O’Riordan
- Tyndall National Institute, University College Cork, T12 R5CP Cork, Ireland;
| | - Rosalinda Inguanta
- Dipartimento di Ingegneria, Università degli Studi di Palermo, 90128 Palermo, Italy; (B.P.); (N.M.); (G.R.); (G.A.)
| |
Collapse
|