1
|
Kocaturk O, Keles S. Comparison of the HugeMed video laryngoscope with the Macintosh direct laryngoscope for nasotracheal tracheal intubation in children undergoing dental treatment: a randomized controlled clinical study. Expert Rev Med Devices 2024:1-8. [PMID: 38829609 DOI: 10.1080/17434440.2024.2363289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2024] [Accepted: 04/26/2024] [Indexed: 06/05/2024]
Abstract
OBJECTIVES The aim of this study was to compare the performance of the HugeMed® videolaryngoscope with a direct Macintosh laryngoscope for nasotracheal intubation. METHODS Eighty-eight children aged 4-10 years were randomly assigned to either the HugeMed® videolaryngoscope (HVL) or the Macintosh direct laryngoscope (MDL) group. Intubation difficulty, glottic view grade, time-to-intubation, number of tracheal intubation attempts, use of external laryngeal manipulation and Magill forceps, recovery time, pediatric-anesthesia-delirium-scale (PAEDS) scores, pain due to tracheal intubation, and laryngeal bleeding were evaluated. RESULTS Easy tracheal intubation incidence was higher in the HVL group than that in the MDL group (p = 0.001). Glottic view was better in the HVL group as compared to the MDL group (p = 0.027). There was no difference between the groups in terms of time-to-tracheal intubation, number of tracheal intubation attempts, Magill forceps usage, pain, and bleeding due to tracheal intubation. The need for external laryngeal manipulation (p = 0.004) and PAEDS scores (p = 0.006) were higher in the MDL group than those in the HVL group. CONCLUSION HugeMed® videolaryngoscope may provide easier tracheal intubation, create a better glottic view, and significantly reduce the need for additional manipulation compared to the Macintosh direct laryngoscope, for nasotracheal intubation. CLINICAL TRIAL REGISTRATION www.clinicaltrial.gov identifier is NCT05121597.
Collapse
Affiliation(s)
- Ozlem Kocaturk
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Division of Anesthesiology, Aydin Adnan Menderes University, Aydın, Turkey
| | - Sultan Keles
- Department of Pediatric Dentistry, Faculty of Dentistry, Aydin Adnan Menderes University, Aydin, Turkey
| |
Collapse
|
2
|
Masui K, Asai T, Saito T, Okuda Y. Efficacy of McGRATH®MAC videolaryngoscope blade 1 for tracheal intubation in small children: a randomized controlled clinical study. J Anesth 2023:10.1007/s00540-023-03207-2. [PMID: 37311898 DOI: 10.1007/s00540-023-03207-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2023] [Accepted: 05/29/2023] [Indexed: 06/15/2023]
Abstract
BACKGROUND Videolaryngoscopes may not be as effective in small children as they are in older children and in adults. The size 1 blade is commercially available for the McGRATH®MAC videolaryngoscope (Covidien, Medtronic, Tokyo, Japan), but its efficacy in comparison with a Macintosh laryngoscope blade 1 is not known. AIM The main aim of this study was to assess the efficacy of McGrath®MAC blade 1 in comparison with a conventional Macintosh laryngoscope blade 1, in children aged less than 24 months. METHODS Thirty-eight children aged less than 24 months were randomly allocated to one of two groups, and tracheal intubation was attempted using either a direct laryngoscope with a Macintosh blade 1 or a videolaryngoscope with a McGRATH®MAC blade 1. In another 12 children aged 2-4 years, the same comparisons were made with blade 2. The primary outcome measure was time to tracheal intubation using a size 1 blade. RESULTS Tracheal intubation took significantly longer with a McGRATH®MAC blade 1 (median (interquartile range): 38.0 (31.8-43.5) s) than with the Macintosh blade 1(27.4 (25.9-29.2) s) (p < 0.0001; median difference (95% CI for the median difference): 10.6 (6.4-14.0) s), mainly due to difficulty in advancing a tube into the trachea. No significant difference was observed for the size 2. CONCLUSIONS In small children without predicted difficult airways, time to intubate the trachea was significantly longer for a McGRATH®MAC blade 1 than a Macintosh blade 1. CLINICAL TRIAL REGISTRATION jRCT1032220366.
Collapse
Affiliation(s)
- Katsuhide Masui
- Department of Anesthesiology, Dokkyo Medical University Saitama Medical Center, 2-1-50 Minami-Koshigaya, Koshigaya City, Saitama, 343-8555, Japan.
| | - Takashi Asai
- Department of Anesthesiology, Dokkyo Medical University Saitama Medical Center, 2-1-50 Minami-Koshigaya, Koshigaya City, Saitama, 343-8555, Japan
| | - Tomoyuki Saito
- Department of Anesthesiology, Dokkyo Medical University Saitama Medical Center, 2-1-50 Minami-Koshigaya, Koshigaya City, Saitama, 343-8555, Japan
| | - Yasuhisa Okuda
- Department of Anesthesiology, Dokkyo Medical University Saitama Medical Center, 2-1-50 Minami-Koshigaya, Koshigaya City, Saitama, 343-8555, Japan
| |
Collapse
|
3
|
Effectiveness of Indirect and Direct Laryngoscopes in Pediatric Patients: A Systematic Review and Network Meta-Analysis. CHILDREN 2022; 9:children9091280. [PMID: 36138589 PMCID: PMC9497385 DOI: 10.3390/children9091280] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/29/2022] [Revised: 08/20/2022] [Accepted: 08/21/2022] [Indexed: 11/17/2022]
Abstract
This research aimed to produce a coherent ranking of the effectiveness of intubation devices in pediatric patients using network meta-analysis (NMA). We searched the electric databases for prospective randomized studies that compared different tracheal intubation devices in pediatric patients. The primary outcome was intubation failure at the first attempt. Secondary outcomes were glottic visualization and intubation time. The statistical analysis performed used DerSimonian and Laird random-effects models. Frequentist network meta-analysis was conducted, and network plots and network league tables were produced. Subgroup analysis was performed after excluding rigid-fiberscope-type indirect laryngoscopes. Thirty-four trials comparing 13 devices were included. Most laryngoscopes had the same intubation failure rate as the Macintosh reference device. Only the Truview PCD™ had a significantly higher intubation failure rate than the Macintosh (odds ratio 4.78, 95% confidence interval 1.11–20.6) The highest-ranking laryngoscope was the Airtaq™ (P score, 0.90), and the AirwayScope™, McGrath™, and Truview EVO2™ ranked higher than the Macintosh. The Bullard™ had the lowest ranking (P score, 0.08). All laryngoscopes had the same level of glottic visualization as the Macintosh and only the C-MAC™ had a significantly shorter intubation time. Intubation time was significantly longer when using the GlideScope™, Storz DCI™, Truview PCD™, or Bullard™ compared with the Macintosh. P score and ranking of devices in the subgroup analyses were similar to those in the main analysis. We applied NMA to create a consistent ranking of the effectiveness of intubation devices in pediatric patients. The findings of NMA suggest that there is presently no laryngoscope superior to the Macintosh laryngoscope in terms of tracheal intubation failure rate and glottic visualization in pediatric patients.
Collapse
|
4
|
Dean P, Kerrey B. Video screen visualization patterns when using a video laryngoscope for tracheal intubation: A systematic review. J Am Coll Emerg Physicians Open 2022; 3:e12630. [PMID: 35028640 PMCID: PMC8738719 DOI: 10.1002/emp2.12630] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2021] [Revised: 11/08/2021] [Accepted: 11/23/2021] [Indexed: 11/18/2022] Open
Abstract
OBJECTIVE Published studies of video laryngoscopes are often limited by the lack of a clear definition of video laryngoscopy (VL). We performed a systematic review to determine how often published studies of VL report on video screen visualization. METHODS We searched PubMed, EMBASE and Scopus for interventional and observational studies in which a video laryngoscope equipped with a standard geometry blade was used for tracheal intubation. We excluded simulation based studies. Our primary outcome was data on video laryngoscope screen visualization. Secondary outcomes were explicit methodology for screen visualization. RESULTS We screened 4838 unique studies and included 207 (120 interventional and 87 observational). Only 21 studies (10% of 207) included any data on video screen visualization by the proceduralist, 19 in a yes/no fashion only (ie, screened viewed or not) and 2 with detail beyond whether the screen was viewed or not. In 11 more studies, visualization patterns could be inferred based on screen availability and in 16 more studies, the methods section stated how screen visualization was expected to be performed without reporting data collection on how the proceduralist interacted with the video screen. Risk of bias was high in the majority of included studies. CONCLUSIONS Published studies of VL, including many clinical trials, rarely include data on video screen visualization. Given the nuances of using a video laryngoscope, this is a critical deficiency, which largely prevents us from knowing the treatment effect of using a video laryngoscope in clinical practice. Future studies of VL must address this deficiency.
Collapse
Affiliation(s)
- Preston Dean
- Division of Emergency MedicineCincinnati Children's Hospital Medical CenterCincinnatiOhioUSA
| | - Benjamin Kerrey
- Division of Emergency MedicineCincinnati Children's Hospital Medical CenterCincinnatiOhioUSA
- Department of PediatricsUniversity of Cincinnati College of MedicineCincinnatiOhioUSA
| |
Collapse
|
5
|
Dean P, Edmunds K, Shah A, Frey M, Zhang Y, Boyd S, Kerrey BT. Video Laryngoscope Screen Visualization and Tracheal Intubation Performance: A Video-Based Study in a Pediatric Emergency Department. Ann Emerg Med 2021; 79:323-332. [PMID: 34952729 DOI: 10.1016/j.annemergmed.2021.11.019] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Revised: 11/11/2021] [Accepted: 11/16/2021] [Indexed: 11/01/2022]
Abstract
STUDY OBJECTIVE Our study objectives were to describe patterns of video laryngoscope screen visualization during tracheal intubation in a pediatric emergency department (ED) and to determine their associations with procedural performance. METHODS We conducted a prospective, observational, video-based study of pediatric ED patients undergoing tracheal intubation with a standard geometry video laryngoscope (Storz C-MAC; Karl Storz, Tuttlingen, Germany). Our primary exposure was video screen visualization patterns, measured by the percentage of each attempt spent viewing the screen and the number of times the proceduralist changed their gaze between the patient and screen (gaze switches). Our primary outcome was first-pass success. We compared measures of screen visualization between successful and unsuccessful first attempts using a generalized linear mixed model. RESULTS From December 2019 to October 2021, we collected data on 153 patients. The first-pass success rate was 79.1%. Proceduralists viewed the video screen during 80.4% of attempts; the median percentage of each attempt spent viewing the video screen was 42.1% (interquartile range 8.7% to 65.5%). The median number of gaze switches per attempt was 3 (interquartile range 1 to 6, maximum 22). The percentage of each attempt spent viewing the video screen was not associated with success (adjusted odds ratio 1.00, 95% confidence interval 0.93 to 1.08); additional gaze switches were associated with a lower likelihood of success (adjusted odds ratio 0.80, 95% confidence interval 0.71 to 0.90). CONCLUSION We found wide variation in how proceduralists viewed the video laryngoscope screen during intubations in a pediatric ED. We illustrate the application of 2 objective screen visualization measures to quantify and understand how clinicians actually use video laryngoscopy.
Collapse
Affiliation(s)
- Preston Dean
- Division of Emergency Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH.
| | - Katherine Edmunds
- Division of Emergency Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH; Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH
| | - Ashish Shah
- Division of Emergency Medicine, Rady Children's Hospital, San Diego, CA
| | - Mary Frey
- Division of Emergency Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH
| | - Yin Zhang
- Division of Emergency Medicine, and the Division of Biostatistics and Epidemiology, Cincinnati Children's Hospital Medical Center, Cincinnati, OH
| | - Stephanie Boyd
- Division of Emergency Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH
| | - Benjamin T Kerrey
- Division of Emergency Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH; Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH
| |
Collapse
|
6
|
Salzman GA, El H, Chang TP. Impact of Environmental Noise Levels on Endotracheal Intubation Performance Among Pediatric Emergency Providers: A Simulation Study. Pediatr Emerg Care 2021; 37:e944-e949. [PMID: 30964852 DOI: 10.1097/pec.0000000000001831] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND The emergency department is a stressful workplace environment with environmental stimuli and distractions, including noise. This has potential effects on perceived stress for providers and critical procedure performance. OBJECTIVE This study aimed to characterize the impact of environmental noise levels on the time to intubate, the quality of intubation, and physiologic stress response in pediatric emergency department providers. METHODS This was a randomized control simulation-based study in which experienced pediatric providers intubated an adult manikin 3 times while experiencing 3 different ambient noise levels (60, 75, 80 dB) in random order. Participants' times to intubate were measured, as was the endotracheal tube depth. The quality of each intubation attempt was assessed via video review against a standardized checklist. Lastly, participants' heart rates were monitored in real time to assess for physiologic stress response. Differences in performance were analyzed using a repeated-measures analysis of variance. RESULTS No significant difference was found between noise levels and time to intubate (P = 0.19), although each subsequent attempt shortened the time to intubate (P = 0.01). Physiological heart rate changes did not differ by noise level (P = 0.35). Subjectively, "time and economy of motion" and "overall performance" did not differ by noise level but did improve for each subsequent attempt number (P < 0.046). CONCLUSIONS Intubation performance improved with attempt number, but no differences in performance were seen between noise levels. This suggests that rehearsing and practice impacts performance more than environmental noise levels.
Collapse
Affiliation(s)
- Garrett A Salzman
- From the Keck School of Medicine of the University of Southern California
| | - Hanan El
- Division of Emergency and Transport Medicine, Children's Hospital Los Angeles, Los Angeles, CA
| | | |
Collapse
|
7
|
Gupta A, Singh P, Gupta N, Kumar Malhotra R, Girdhar KK. Comparative efficacy of C-MAC ® Miller videolaryngoscope versus McGrath ® MAC size "1" videolaryngoscope in neonates and infants undergoing surgical procedures under general anesthesia: A prospective randomized controlled trial. Paediatr Anaesth 2021; 31:1089-1096. [PMID: 34153141 DOI: 10.1111/pan.14244] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/28/2021] [Revised: 06/03/2021] [Accepted: 06/05/2021] [Indexed: 01/29/2023]
Abstract
BACKGROUND Various anatomical and physiological factors make intubation in infants challenging. C-MAC videolaryngoscope shows better results as compared to the conventional direct laryngoscopy for intubation in infants. McGrath MAC size-1 with a disposable Macintosh type blade has recently been introduced for use in infants and has not been formally evaluated in this population. AIMS This study aims to evaluate the intubation characteristics of C-MAC Miller and McGrath MAC in neonates and infants with the primary objective to compare the time with the two devices. METHODS After informed consent from the parents, 140 neonates and infants scheduled for surgical procedures were randomized to undergo intubation with either C-MAC Miller or McGrath MAC after standard general anesthesia. The two devices were compared in terms of total intubation time, Percent of Glottic Opening score, Cormack Lehane grades, time to glottis view, intubation difficulty score, overall success rate, first attempt success rate, and complications. RESULTS The median glottic view time (6 s [4-9] vs. 6 s [4-9]; p = .40) and intubation time (27 s [25.5-28] vs. 27 s [24.5-29.5]; p = .87) were similar. The mean difference (95% CI) in time to tracheal intubation and time to glottic view was 0.49 s [-3.1 to 2.1] and -1.7 s [-3.8 to 0.47], respectively. However, the Percent of Glottic Opening score, Cormack Lehane grades, and subjective intubation difficulty were significantly better with C-MAC. The first attempt success rates, overall success rates (100% vs. 97.5%), and intubation difficulty scores were comparable. There were two failed intubations with McGrath which were successfully intubated with C-MAC. CONCLUSION The C-MAC Miller blade showed similar intubation timings, success rates, and intubation difficulty score as compared to McGrath MAC in neonates and infants, though the former provided superior glottic views. Both the videolaryngoscopes may be safely used in infants and neonates for routine intubation scenarios.
Collapse
Affiliation(s)
- Anju Gupta
- Department of Anaesthesiology, Pain Medicine and Critical care, All India Institute of Medical Sciences, New Delhi, 110029, India
| | - Pooja Singh
- Department of Anaesthesiology and Intensive Care, VMMC and Safdarjung Hospital, New Delhi, 110029, India
| | - Nishkarsh Gupta
- Department of Onco-Anaesthesiology and Palliative Medicine, DR BRAIRCH, All India Institute of Medical Sciences, New Delhi, 110029, India
| | | | - Kiran Kumar Girdhar
- Department of Anaesthesiology and Intensive Care, VMMC and Safdarjung Hospital, New Delhi, 110029, India
| |
Collapse
|
8
|
Couto TB, Reis AG, Farhat SCL, Carvalho VEDL, Schvartsman C. Changing the view: Video versus direct laryngoscopy for intubation in the pediatric emergency department. Medicine (Baltimore) 2020; 99:e22289. [PMID: 32957386 PMCID: PMC7505323 DOI: 10.1097/md.0000000000022289] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
The aim of this study was to compare the success of first-attempt tracheal intubation in pediatric patients >1-year old performed using video versus direct laryngoscopy and compare the frequency of tracheal intubation-associated events and desaturation among these patients.Prospective observational cohort study conducted in an Academic pediatric tertiary emergency department. We compared 50 children intubated with Mcgrath Mac video laryngoscope (VL group) and an historical series of 141 children intubated with direct laryngoscopy (DL group). All patients were aged 1 to 18 years.The first attempt success rates were 68% (34/50) and 37.6% (53/141) in the VL and DL groups (P < .01), respectively. There was a lower proportion of tracheal intubation-associated events in the VL group (VL, 31.3% [15/50] vs DL, 67.8% [97/141]; P < .01) and no significant differences in desaturation (VL, 35% [14/50] vs DL 51.8% [72/141]; P = .06). The median number of attempts was 1 (range, 1-5) for the VL group and 2 (range, 1-8) for the DL group (P < .01). Multivariate logistic regression showed that video laryngoscope use was associated with higher chances of first-attempt intubation with an odds ratio of 4.5 (95% confidence interval, 1.9-10.4, P < 0.01).Compared with direct laryngoscopy, VL was associated with higher success rates of first-attempt tracheal intubations and lower rates of tracheal intubation-associated events.
Collapse
|
9
|
Dadure C, Sabourdin N, Veyckemans F, Babre F, Bourdaud N, Dahmani S, Queiroz MD, Devys JM, Dubois MC, Kern D, Laffargue A, Laffon M, Lejus-Bourdeau C, Nouette-Gaulain K, Orliaguet G, Gayat E, Velly L, Salvi N, Sola C. Management of the child's airway under anaesthesia: The French guidelines. Anaesth Crit Care Pain Med 2019; 38:681-693. [PMID: 30807876 DOI: 10.1016/j.accpm.2019.02.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
OBJECTIVE To provide French guidelines about "Airway management during paediatric anaesthesia". DESIGN A consensus committee of 17 experts from the French Society of Anaesthesia and Intensive Care Medicine (Société Française d'Anesthésie-Réanimation, SFAR) and the Association of French speaking paediatric anaesthesiologists and intensivists (Association Des Anesthésistes Réanimateurs Pédiatriques d'Expression Francophone, ADARPEF) was convened. The entire process was conducted independently of any industry funding. The authors followed the principles of the Grading of Recommendations Assessment, Development and Evaluation (GRADE®) system to assess the quality of evidence. The potential drawbacks of making strong recommendations in the presence of low-quality evidence were emphasised. Few recommendations were not graded. METHODS The panel focused on 7 questions: 1) Supraglottic Airway devices 2) Cuffed endotracheal tubes 3) Videolaryngoscopes 4) Neuromuscular blocking agents 5) Rapid sequence induction 6) Airway device removal 7) Airway management in the child with recent or ongoing upper respiratory tract infection. Population, intervention, comparison, and outcomes (PICO) questions were reviewed and updated as needed, and evidence profiles were generated. The analysis of the literature and the redaction of the recommendations were then conducted according to the GRADE® methodology. RESULTS The SFAR Guideline panel provides 17 statements on "airway management during paediatric anaesthesia". After two rounds of discussion and various amendments, a strong agreement was reached for 100% of the recommendations. Of these recommendations, 6 have a high level of evidence (Grade 1 ± ), 6 have a low level of evidence (Grade 2 ± ) and 5 are experts' opinions. No recommendation could be provided for 3 questions. CONCLUSIONS Substantial agreement exists among experts regarding many strong recommendations for paediatric airway management.
Collapse
Affiliation(s)
- Christophe Dadure
- Département d'anesthesiologie réanimation femme-mère-enfant, CHU de Lapeyronie, institut de génomique fonctionnelle, UMR 5203 CNRS - U 1191 Inserm, université de Montpellier, 34285 Montpellier, France.
| | - Nada Sabourdin
- Département d'anesthésiologie-réanimation hôpital Armand Trousseau, AP-HP, 26, avenue du Dr Arnold-Netter, 75012 Paris, France
| | - Francis Veyckemans
- Department of paediatric anaesthesia, Jeanne de Flandre hospital, university hospitals of Lille, 59037 Lille, France
| | - Florence Babre
- Department of anaesthesia, Bergonié institute, 33000 Bordeaux, France
| | - Nathalie Bourdaud
- Département d'Anesthésiologie Réanimation Pédiatrique, Hôpital Femme Mère Enfant, 69677 Bron, France
| | - Souhayl Dahmani
- Department of anaesthesia and intensive care. Robert-Debré university hospital, assistance publique Hôpitaux de Paris, Paris Diderot University, Paris Sorbonne Cité, Paris, Paris Diderot University (Paris VII), PRES Paris Sorbonne Cité, Paris, DHU PROTECT, Inserm U1141, Robert-Debré University Hospital, 75019 Paris, France
| | - Mathilde De Queiroz
- Département d'Anesthésiologie Réanimation Pédiatrique, Hôpital Femme Mère Enfant, 69677 Bron, France
| | - Jean-Michel Devys
- Service d'anesthésie-réanimation, fondation ophtalmologique Adolphe de Rothschild, 25, rue Manin, 75019 Paris, France
| | - Marie-Claude Dubois
- Service d'anesthésie-réanimation, fondation ophtalmologique Adolphe de Rothschild, 25, rue Manin, 75019 Paris, France
| | - Delphine Kern
- Departments of anaesthesia and intensive care, university hospital of Toulouse, place du Dr Baylac, TSA 40031, 31059 Toulouse cedex 9, France
| | - Anne Laffargue
- Department of paediatric anaesthesia, Jeanne de Flandre hospital, university hospitals of Lille, 59037 Lille, France
| | - Marc Laffon
- Department of anesthesia and intensive care, university hospital and medical university François-Rabelais, Tours, France
| | - Corinne Lejus-Bourdeau
- Service d'anesthesie réanimation chirurgicale, Hôtel Dieu, Hôpital Mère Enfant, CHU de Nantes, 44093 Nantes cedex, France
| | - Karine Nouette-Gaulain
- Service d'anesthésie réanimation Pellegrin, hôpital Pellegrin, CHU de Bordeaux, place Amélie Raba Léon, 33000 Bordeaux, France; Université Bordeaux, Inserm U12-11, laboratoire de maladies rares: génétique et métabolisme (MRGM), 176, rue Léo-Saignat, 33000 Bordeaux, France
| | - Gilles Orliaguet
- Department of anaesthesia and intensive care, assistance publique Hôpitaux de Paris, Necker-Enfants Malades hospital, EA08 pharmacologie et évaluation des thérapeutiques chez l'enfant et la femme enceinte, Paris Descartes University (Paris V), PRES Paris Sorbonne Cité, 75743 Paris, France
| | - Etienne Gayat
- Department of anesthesiology and Intensive care, Saint Louis, Lariboisière university hospital, université Paris Diderot, BioCANVAS, UMR-S 942, Inserm, 75010 Paris, France
| | - Lionel Velly
- Service d'anesthesie réanimation, CHU de Timone adultes, 264, rue St Pierre, 13005 MeCA, institut de neurosciences de la Timone, UMR 7289, Aix Marseille université, Marseille, France
| | - Nadège Salvi
- Department of anaesthesia and intensive care, assistance publique Hôpitaux de Paris, Necker-Enfants Malades Hospital, 75743 Paris, France
| | - Chrystelle Sola
- Département d'anesthesiologie réanimation femme-mère-enfant, CHU de Lapeyronie, institut de génomique fonctionnelle, UMR 5203 CNRS - U 1191 Inserm, université de Montpellier, 34285 Montpellier, France
| |
Collapse
|
10
|
Hsu MY, Hsiao WT, Chang HC. Designing A Video Laryngoscope Imaging System with A 7-mm Blade for Neonatal Patients. SMART SCIENCE 2018. [DOI: 10.1080/23080477.2018.1460891] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Affiliation(s)
- Ming-Ying Hsu
- Experimental Facility Division, National Synchrotron Radiation Research Center, Hsinchu, Taiwan, ROC
| | - Wen-Tse Hsiao
- National Applied Research Laboratories, Instrument Technology Research Center, Hsinchu, Taiwan, ROC
| | - Han-Chao Chang
- National Applied Research Laboratories, Instrument Technology Research Center, Hsinchu, Taiwan, ROC
| |
Collapse
|
11
|
Comparing McGrath ® MAC video laryngoscope with Macintosh direct laryngoscopy for novice laryngoscopists in children. Anaesth Crit Care Pain Med 2017; 37:81-82. [PMID: 29133270 DOI: 10.1016/j.accpm.2017.11.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2017] [Accepted: 11/09/2017] [Indexed: 11/21/2022]
|
12
|
Giraudon A, Bordes-Demolis M, Semjen F, Biais M, Nouette-Gaulain K. Comparing McGrath ® MAC video laryngoscope with Macintosh direct laryngoscopy for novice laryngoscopists in children. Reply. Anaesth Crit Care Pain Med 2017; 37:473. [PMID: 29133267 DOI: 10.1016/j.accpm.2017.10.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2017] [Accepted: 10/28/2017] [Indexed: 10/18/2022]
Affiliation(s)
- Antoine Giraudon
- Anaesthesia and critical care department 3, centre hospitalier universitaire de Bordeaux, place Amélie-Raba-Léon, 33076 Bordeaux, France.
| | - Maryline Bordes-Demolis
- Anaesthesia and critical care department 3, centre hospitalier universitaire de Bordeaux, place Amélie-Raba-Léon, 33076 Bordeaux, France
| | - François Semjen
- Anaesthesia and critical care department 3, centre hospitalier universitaire de Bordeaux, place Amélie-Raba-Léon, 33076 Bordeaux, France
| | - Matthieu Biais
- Anaesthesia and critical care department 3, centre hospitalier universitaire de Bordeaux, place Amélie-Raba-Léon, 33076 Bordeaux, France
| | - Karine Nouette-Gaulain
- Anaesthesia and critical care department 3, centre hospitalier universitaire de Bordeaux, place Amélie-Raba-Léon, 33076 Bordeaux, France
| |
Collapse
|
13
|
Video-laryngoscopes for intubation in paediatrics: Is a better view makes everything? Anaesth Crit Care Pain Med 2017; 36:259-260. [PMID: 28412494 DOI: 10.1016/j.accpm.2017.04.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|