1
|
Yang J, Yee PL, Khan AA, Karamti H, Eldin ET, Aldweesh A, Jery AE, Hussain L, Omar A. Intelligent lung cancer MRI prediction analysis based on cluster prominence and posterior probabilities utilizing intelligent Bayesian methods on extracted gray-level co-occurrence (GLCM) features. Digit Health 2023; 9:20552076231172632. [PMID: 37256015 PMCID: PMC10226179 DOI: 10.1177/20552076231172632] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Accepted: 04/12/2023] [Indexed: 06/01/2023] Open
Abstract
Lung cancer is the second foremost cause of cancer due to which millions of deaths occur worldwide. Developing automated tools is still a challenging task to improve the prediction. This study is specifically conducted for detailed posterior probabilities analysis to unfold the network associations among the gray-level co-occurrence matrix (GLCM) features. We then ranked the features based on t-test. The Cluster Prominence is selected as target node. The association and arc analysis were determined based on mutual information. The occurrence and reliability of selected cluster states were computed. The Cluster Prominence at state ≤330.85 yielded ROC index of 100%, relative Gini index of 99.98%, and relative Gini index of 100%. The proposed method further unfolds the dynamics and to detailed analysis of computed features based on GLCM features for better understanding of the hidden dynamics for proper diagnosis and prognosis of lung cancer.
Collapse
Affiliation(s)
- Jing Yang
- Faculty of Computer Science and
Information Technology, Universiti Malaya, Kuala Lumpur, Malaysia
| | - Por Lip Yee
- Faculty of Computer Science and
Information Technology, Universiti Malaya, Kuala Lumpur, Malaysia
| | - Abdullah Ayub Khan
- Department of Computer Science and
Information Technology, Benazir Bhutto Shaheed University Lyari, Karachi,
Pakistan
| | - Hanen Karamti
- Department of Computer Sciences,
College of Computer and Information Sciences, Princess Nourah bint Abdulrahman
University, Riyadh, Saudi Arabia
| | - Elsayed Tag Eldin
- Faculty of Engineering and Technology, Future University in Egypt, New Cairo, Cairo, Egypt
| | - Amjad Aldweesh
- College of Computer Science and
Information Technology, Shaqra University, Shaqra, Saudi Arabia
| | - Atef El Jery
- Department of Chemical Engineering,
College of Engineering, King Khalid University, Abha, Saudi Arabia
- National Engineering School of Gabes,
Gabes University, Zrig Gabes, Tunisia
| | - Lal Hussain
- Department of Computer Science and
Information Technology, King Abdullah Campus Chatter Kalas, University of Azad Jammu
and Kashmir, Muzaffarabad, Azad Kashmir, Pakistan
- Department of Computer Science and
Information Technology, University of Azad Jammu and Kashmir, Athmuqam, Azad
Kashmir, Pakistan
| | - Abdulfattah Omar
- Department of English, College of
Science & Humanities, Prince Sattam Bin Abdulaziz
University, Al-Kharj, Saudi Arabia
| |
Collapse
|
2
|
Kobayashi H, Ohkubo M, Narita A, Marasinghe JC, Murao K, Matsumoto T, Sone S, Wada S. A method for evaluating the performance of computer-aided detection of pulmonary nodules in lung cancer CT screening: detection limit for nodule size and density. Br J Radiol 2017; 90:20160313. [PMID: 27897029 DOI: 10.1259/bjr.20160313] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE We propose the application of virtual nodules to evaluate the performance of computer-aided detection (CAD) of lung nodules in cancer screening using low-dose CT. METHODS The virtual nodules were generated based on the spatial resolution measured for a CT system used in an institution providing cancer screening and were fused into clinical lung images obtained at that institution, allowing site specificity. First, we validated virtual nodules as an alternative to artificial nodules inserted into a phantom. In addition, we compared the results of CAD analysis between the real nodules (n = 6) and the corresponding virtual nodules. Subsequently, virtual nodules of various sizes and contrasts between nodule density and background density (ΔCT) were inserted into clinical images (n = 10) and submitted for CAD analysis. RESULTS In the validation study, 46 of 48 virtual nodules had the same CAD results as artificial nodules (kappa coefficient = 0.913). Real nodules and the corresponding virtual nodules showed the same CAD results. The detection limits of the tested CAD system were determined in terms of size and density of peripheral lung nodules; we demonstrated that a nodule with a 5-mm diameter was detected when the nodule had a ΔCT > 220 HU. CONCLUSION Virtual nodules are effective in evaluating CAD performance using site-specific scan/reconstruction conditions. Advances in knowledge: Virtual nodules can be an effective means of evaluating site-specific CAD performance. The methodology for guiding the detection limit for nodule size/density might be a useful evaluation strategy.
Collapse
Affiliation(s)
- Hajime Kobayashi
- 1 Graduate School of Health Sciences, Niigata University, Niigata, Japan.,2 Department of Radiology, Sannocho Hospital, Niigata, Japan
| | - Masaki Ohkubo
- 1 Graduate School of Health Sciences, Niigata University, Niigata, Japan
| | - Akihiro Narita
- 1 Graduate School of Health Sciences, Niigata University, Niigata, Japan
| | - Janaka C Marasinghe
- 1 Graduate School of Health Sciences, Niigata University, Niigata, Japan.,3 Department of Radiography and Radiotherapy, Faculty of Allied Health Sciences, University of Peradeniya, Peradeniya, Sri Lanka
| | | | | | - Shusuke Sone
- 6 JA Nagano Azumi General Hospital, Nagano, Japan.,7 Present Address: Chest Imaging Division, Nagano Health Promotion Corporation, Nagano, Japan
| | - Shinichi Wada
- 1 Graduate School of Health Sciences, Niigata University, Niigata, Japan
| |
Collapse
|
3
|
Baldwin D, Callister M. What is the Optimum Screening Strategy for the Early Detection of Lung Cancer. Clin Oncol (R Coll Radiol) 2016; 28:672-681. [DOI: 10.1016/j.clon.2016.08.001] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2016] [Revised: 07/04/2016] [Accepted: 07/11/2016] [Indexed: 01/26/2023]
|
4
|
Effect of radiation dose reduction and iterative reconstruction on computer-aided detection of pulmonary nodules: Intra-individual comparison. Eur J Radiol 2015; 85:346-51. [PMID: 26781139 DOI: 10.1016/j.ejrad.2015.12.003] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2015] [Revised: 11/30/2015] [Accepted: 12/05/2015] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To evaluate the effect of radiation dose reduction and iterative reconstruction (IR) on the performance of computer-aided detection (CAD) for pulmonary nodules. METHODS In this prospective study twenty-five patients were included who were scanned for pulmonary nodule follow-up. Image acquisition was performed at routine dose and three reduced dose levels in a single session by decreasing mAs-values with 45%, 60% and 75%. Tube voltage was fixed at 120 kVp for patients ≥ 80 kg and 100 kVp for patients < 80 kg. Data were reconstructed with filtered back projection (FBP), iDose(4) (levels 1,4,6) and IMR (levels 1-3). All noncalcified solid pulmonary nodules ≥ 4 mm identified by two radiologists in consensus served as the reference standard. Subsequently, nodule volume was measured with CAD software and compared to the reference consensus. The numbers of true-positives, false-positives and missed pulmonary nodules were evaluated as well as the sensitivity. RESULTS Median effective radiation dose was 2.2 mSv at routine dose and 1.2, 0.9 and 0.6 mSv at respectively 45%, 60% and 75% reduced dose. A total of 28 pulmonary nodules were included. With FBP at routine dose, 89% (25/28) of the nodules were correctly identified by CAD. This was similar at reduced dose levels with FBP, iDose(4) and IMR. CAD resulted in a median number of false-positives findings of 11 per scan with FBP at routine dose (93% of the CAD marks) increasing to 15 per scan with iDose(4) (95% of the CAD marks) and 26 per scan (96% of the CAD marks) with IMR at the lowest dose level. CONCLUSION CAD can identify pulmonary nodules at submillisievert dose levels with FBP, hybrid and model-based IR. However, the number of false-positive findings increased using hybrid and especially model-based IR at submillisievert dose while dose reduction did not affect the number of false-positives with FBP.
Collapse
|
5
|
Li F. Potential clinical impact of advanced imaging and computer-aided diagnosis in chest radiology: importance of radiologist's role and successful observer study. Radiol Phys Technol 2015; 8:161-73. [PMID: 25981309 DOI: 10.1007/s12194-015-0319-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2015] [Accepted: 05/06/2015] [Indexed: 11/29/2022]
Abstract
This review paper is based on our research experience in the past 30 years. The importance of radiologists' role is discussed in the development or evaluation of new medical images and of computer-aided detection (CAD) schemes in chest radiology. The four main topics include (1) introducing what diseases can be included in a research database for different imaging techniques or CAD systems and what imaging database can be built by radiologists, (2) understanding how radiologists' subjective judgment can be combined with technical objective features to improve CAD performance, (3) sharing our experience in the design of successful observer performance studies, and (4) finally, discussing whether the new images and CAD systems can improve radiologists' diagnostic ability in chest radiology. In conclusion, advanced imaging techniques and detection/classification of CAD systems have a potential clinical impact on improvement of radiologists' diagnostic ability, for both the detection and the differential diagnosis of various lung diseases, in chest radiology.
Collapse
Affiliation(s)
- Feng Li
- Department of Radiology, MC 2026, The University of Chicago, 5841 S. Maryland Avenue, Chicago, IL, 60637, USA,
| |
Collapse
|
6
|
Scholten ET, Horeweg N, de Koning HJ, Vliegenthart R, Oudkerk M, Mali WPTM, de Jong PA. Computed tomographic characteristics of interval and post screen carcinomas in lung cancer screening. Eur Radiol 2014; 25:81-8. [DOI: 10.1007/s00330-014-3394-4] [Citation(s) in RCA: 63] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2013] [Revised: 08/02/2014] [Accepted: 08/11/2014] [Indexed: 12/14/2022]
|
7
|
Woloszynski T, Podsiadlo P, Stachowiak G, Kurzynski M. A dissimilarity-based multiple classifier system for trabecular bone texture in detection and prediction of progression of knee osteoarthritis. Proc Inst Mech Eng H 2013. [PMID: 23185959 DOI: 10.1177/0954411912456650] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
There is a growing need for classification systems that can accurately detect and predict knee osteoarthritis (OA) from plain radiographs. For this purpose, a system based on a support vector machine (SVM) classifier and distances measured between trabecular bone (TB) texture images was developed and tested in previous work. Unlike other systems, it allows an image classification without the calculation and selection of numerous texture features, and it is invariant to a range of imaging conditions encountered in a routine X-ray screening of knees. Although the system exhibited 85.4% classification accuracy in OA detection, which was higher than those obtained from other systems, its performance could be further improved. To achieve this, a dissimilarity-based multiple classifier (DMC) system is developed in this study. The system measures distances between TB texture images and generates a diverse ensemble of classifiers using prototype selection, bootstrapping of training set and heterogeneous classifiers. A measure of competence is used to select accurate (i.e. better-than-random) classifiers from the ensemble, which are then combined through the majority voting rule. To evaluate the newly developed system in OA detection (prediction of OA progression), TB texture images selected on standardised radiographs of healthy and OA (non-progressive and progressive OA) knees were used. The results obtained showed that the DMC system has higher classification accuracies for the detection (90.51% with 87.65% specificity and 93.33% sensitivity) and prediction (80% with 82.00% specificity and 77.97% sensitivity) than other systems, indicating its potential as a decision-support tool for the assessment of radiographic knee OA.
Collapse
Affiliation(s)
- Tomasz Woloszynski
- Tribology Laboratory, School of Mechanical and Chemical Engineering, The University of Western Australia, Perth, WA, Australia.
| | | | | | | |
Collapse
|
8
|
Fardanesh M, White C. Missed lung cancer on chest radiography and computed tomography. Semin Ultrasound CT MR 2012; 33:280-7. [PMID: 22824118 DOI: 10.1053/j.sult.2012.01.006] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Missed lung cancer raises an important medicolegal issue and contributes to one of the most common causes for malpractice actions against radiologists. Lung cancer may be missed on either chest radiography or computed tomography. Although most malpractice cases involve lesions overlooked on the former, a small and increasing portion of cases are related to chest computed tomography scan. Factors contributing to overlooked lung cancer can be attributed to observer performance, lesion characteristics, and technical considerations.
Collapse
Affiliation(s)
- Mahmoudreza Fardanesh
- Department of Radiology, University of Maryland School of Medicine, 22 S. Greene Street, Baltimore, Maryland 21201, USA.
| | | |
Collapse
|
9
|
Henschke CI, Yankelevitz DF, Reeves AP, Cham MD. Image analysis of small pulmonary nodules identified by computed tomography. ACTA ACUST UNITED AC 2012; 78:882-93. [PMID: 22069212 DOI: 10.1002/msj.20300] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Detection of small pulmonary nodules has markedly increased as computed tomography (CT) technology has advanced and interpretation evolved from viewing small CT images on film to magnified images on large, high-resolution computer monitors. Despite these advances, determining the etiology of a lung nodule short of major surgery remains problematic. Initial nodule size is a major criterion in evaluating the risk for malignancy, and the majority of CT detected nodules are <10 mm in diameter. Also, the likelihood that the nodule is a lung cancer increases with increasing age and smoking history, and such clinical information needs to be integrated into algorithms that guide the workup of such nodules. Baseline and annual repeat screening results are also very helpful in developing and assessing the usefulness of such algorithms. Based on CT morphology, subtypes of nodules have been identified; today nodules are routinely classified as being solid, part-solid, or nonsolid. It has been shown that part-solid nodules have a higher frequency of being malignant than solid or nonsolid ones. Other nodule characteristics such as spiculation are useful, although granulomas and fibrosis also have such features, so these characteristics have not been as useful as nodule-growth assessment. Depending on the aggressiveness of the lung cancer and the size of the nodule when it is initially seen, a follow-up CT scan 1-3 months after the first CT scan can identify those nodules with growth at a malignant rate. Software has been developed by all CT scanner manufacturers for such growth assessment, but the inherent variability of such assessments needs further development. Nodule-growth assessment based on 2-dimensional approaches is limited; therefore, software has been developed for the 3-dimensional assessment of growth. Different approaches for such growth assessment have been developed, either using automated computer segmentation techniques or hybrid methods that allow the radiologist to adjust such segmentation. There are, however, inherent reasons for variability in such measurements that need to be carefully considered, and this, together with continued technologic advances and integration of the relevant clinical information, will allow for individualization of the algorithms for the workup of small pulmonary nodules.
Collapse
Affiliation(s)
- Claudia I Henschke
- Department of Radiology, Mount Sinai School of Medicine, New York, NY, USA.
| | | | | | | |
Collapse
|
10
|
Tumour heterogeneity in non-small cell lung carcinoma assessed by CT texture analysis: a potential marker of survival. Eur Radiol 2011; 22:796-802. [PMID: 22086561 DOI: 10.1007/s00330-011-2319-8] [Citation(s) in RCA: 383] [Impact Index Per Article: 29.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2011] [Revised: 09/09/2011] [Accepted: 09/18/2011] [Indexed: 02/07/2023]
Abstract
PURPOSE To establish the potential for tumour heterogeneity in non-small cell lung cancer (NSCLC) as assessed by CT texture analysis (CTTA) to provide an independent marker of survival for patients with NSCLC. MATERIALS AND METHODS Tumour heterogeneity was assessed by CTTA of unenhanced images of primary pulmonary lesions from 54 patients undergoing (18)F-fluorodeoxyglucose (FDG) PET-CT for staging of NSCLC. CTTA comprised image filtration to extract fine, medium and coarse features with quantification of the distribution of pixel values (uniformity) within the filtered images. Receiver operating characteristics identified thresholds for PET and CTTA parameters that were related to patient survival using Kaplan-Meier analysis. RESULTS The median (range) survival was 29.5 (1-38) months. 24, 10, 14 and 6 patients had tumour stages I, II, III and IV respectively. PET stage and tumour heterogeneity assessed by CTTA were significant independent predictors of survival (PET stage: Odds ratio 3.85, 95% confidence limits 0.9-8.09, P = 0.002; CTTA: Odds ratio 56.4, 95% confidence limits 4.79-666, p = 0.001). SUV was not a significantly associated with survival. CONCLUSION Assessment of tumour heterogeneity by CTTA of non-contrast enhanced images has the potential for to provide a novel, independent predictor of survival for patients with NSCLC. KEY POINTS Computed tomography is a routine staging procedure in non-small cell lung cancer. CT texture analysis (CTTA) can quantify heterogeneity within these lung tumours. CTTA seems to offer a novel independent predictor of survival for NSCLC. CTTA could contribute to disease risk-stratification for patients with NSCLC.
Collapse
|
11
|
Woloszynski T, Podsiadlo P, Stachowiak GW, Kurzynski M. A signature dissimilarity measure for trabecular bone texture in knee radiographs. Med Phys 2010; 37:2030-42. [PMID: 20527536 DOI: 10.1118/1.3373522] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE The purpose of this study is to develop a dissimilarity measure for the classification of trabecular bone (TB) texture in knee radiographs. Problems associated with the traditional extraction and selection of texture features and with the invariance to imaging conditions such as image size, anisotropy, noise, blur, exposure, magnification, and projection angle were addressed. METHODS In the method developed, called a signature dissimilarity measure (SDM), a sum of earth mover's distances calculated for roughness and orientation signatures is used to quantify dissimilarities between textures. Scale-space theory was used to ensure scale and rotation invariance. The effects of image size, anisotropy, noise, and blur on the SDM developed were studied using computer generated fractal texture images. The invariance of the measure to image exposure, magnification, and projection angle was studied using x-ray images of human tibia head. For the studies, Mann-Whitney tests with significance level of 0.01 were used. A comparison study between the performances of a SDM based classification system and other two systems in the classification of Brodatz textures and the detection of knee osteoarthritis (OA) were conducted. The other systems are based on weighted neighbor distance using compound hierarchy of algorithms representing morphology (WND-CHARM) and local binary patterns (LBP). RESULTS Results obtained indicate that the SDM developed is invariant to image exposure (2.5-30 mA s), magnification (x1.00 - x1.35), noise associated with film graininess and quantum mottle (< 25%), blur generated by a sharp film screen, and image size (> 64 x 64 pixels). However, the measure is sensitive to changes in projection angle (> 5 degrees), image anisotropy (> 30 degrees), and blur generated by a regular film screen. For the classification of Brodatz textures, the SDM based system produced comparable results to the LBP system. For the detection of knee OA, the SDM based system achieved 78.8% classification accuracy and outperformed the WND-CHARM system (64.2%). CONCLUSIONS The SDM is well suited for the classification of TB texture images in knee OA detection and may be useful for the texture classification of medical images in general.
Collapse
Affiliation(s)
- T Woloszynski
- Tribology Laboratory, School of Mechanical Engineering, The University of Western Australia, Crawley, Western Australia 6009, Australia
| | | | | | | |
Collapse
|
12
|
A detection method for streak artifacts and radiological noise in a non-uniform region in a CT image. Phys Med 2009; 26:157-65. [PMID: 20036595 DOI: 10.1016/j.ejmp.2009.11.003] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/17/2009] [Revised: 11/13/2009] [Accepted: 11/20/2009] [Indexed: 11/21/2022] Open
Abstract
By using the CT images obtained by subtracting two CT images acquired under the same conditions and slice locations, we have devised a method for detecting streak artifacts in non-uniform regions and only radiological noise components in CT images. A chest phantom was scanned using 16- and 64-multidetector row helical CT scanners with various mAs values at 120kVp. The upper lung slice image was employed as a target image for evaluating the streak artifacts and radiological noise. One hundred parallel line segments with a length of 80 pixels were placed on the subtracted CT image, and the largest CT value in each CT value profile was employed as a feature variable of the streak artifacts; these feature variables were analyzed with the extreme value theory (Gumbel distribution). To detect only the radiological noise, all CT values contained in the 100 line profile were plotted on normal probability paper and the standard deviation was estimated from the inclination of its fitted line for the CT value plots. The two detection methods devised in this study were able to evaluate the streak artifacts and radiological noise in the CT images with high accuracy.
Collapse
|
13
|
Sahiner B, Chan HP, Hadjiiski LM, Cascade PN, Kazerooni EA, Chughtai AR, Poopat C, Song T, Frank L, Stojanovska J, Attili A. Effect of CAD on radiologists' detection of lung nodules on thoracic CT scans: analysis of an observer performance study by nodule size. Acad Radiol 2009; 16:1518-30. [PMID: 19896069 DOI: 10.1016/j.acra.2009.08.006] [Citation(s) in RCA: 75] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2008] [Revised: 08/07/2009] [Accepted: 08/10/2009] [Indexed: 12/21/2022]
Abstract
RATIONALE AND OBJECTIVES To retrospectively investigate the effect of a computer-aided detection (CAD) system on radiologists' performance for detecting small pulmonary nodules in computed tomography (CT) examinations, with a panel of expert radiologists serving as the reference standard. MATERIALS AND METHODS Institutional review board approval was obtained. Our dataset contained 52 CT examinations collected by the Lung Image Database Consortium, and 33 from our institution. All CTs were read by multiple expert thoracic radiologists to identify the reference standard for detection. Six other thoracic radiologists read the CT examinations first without and then with CAD. Performance was evaluated using free-response receiver operating characteristics (FROC) and the jackknife FROC analysis methods (JAFROC) for nodules above different diameter thresholds. RESULTS A total of 241 nodules, ranging in size from 3.0 to 18.6 mm (mean, 5.3 mm) were identified as the reference standard. At diameter thresholds of 3, 4, 5, and 6 mm, the CAD system had a sensitivity of 54%, 64%, 68%, and 76%, respectively, with an average of 5.6 false positives (FPs) per scan. Without CAD, the average figures of merit (FOMs) for the six radiologists, obtained from JAFROC analysis, were 0.661, 0.729, 0.793, and 0.838 for the same nodule diameter thresholds, respectively. With CAD, the corresponding average FOMs improved to 0.705, 0.763, 0.810, and 0.862, respectively. The improvement achieved statistical significance for nodules at the 3 and 4 mm thresholds (P = .002 and .020, respectively), and did not achieve significance at 5 and 6 mm (P = .18 and .13, respectively). At a nodule diameter threshold of 3 mm, the radiologists' average sensitivity and FP rate were 0.56 and 0.67, respectively, without CAD, and 0.67 and 0.78 with CAD. CONCLUSION CAD improves thoracic radiologists' performance for detecting pulmonary nodules smaller than 5 mm on CT examinations, which are often overlooked by visual inspection alone.
Collapse
|
14
|
Golosio B, Masala GL, Piccioli A, Oliva P, Carpinelli M, Cataldo R, Cerello P, De Carlo F, Falaschi F, Fantacci ME, Gargano G, Kasae P, Torsello M. A novel multithreshold method for nodule detection in lung CT. Med Phys 2009; 36:3607-18. [PMID: 19746795 DOI: 10.1118/1.3160107] [Citation(s) in RCA: 61] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Multislice computed tomography (MSCT) is a valuable tool for lung cancer detection, thanks to its ability to identify noncalcified nodules of small size (from about 3 mm). Due to the large number of images generated by MSCT, there is much interest in developing computer-aided detection (CAD) systems that could assist radiologists in the lung nodule detection task. A complete multistage CAD system, including lung boundary segmentation, regions of interest (ROIs) selection, feature extraction, and false positive reduction is presented. The selection of ROIs is based on a multithreshold surface-triangulation approach. Surface triangulation is performed at different threshold values, varying from a minimum to a maximum value in a wide range. At a given threshold value, a ROI is defined as the volume inside a connected component of the triangulated isosurface. The evolution of a ROI as a function of the threshold can be represented by a treelike structure. A multithreshold ROI is defined as a path on this tree, which starts from a terminal ROI and ends on the root ROI. For each ROI, the volume, surface area, roundness, density, and moments of inertia are computed as functions of the threshold and used as input to a classification system based on artificial neural networks. The method is suitable to detect different types of nodules, including juxta-pleural nodules and nodules connected to blood vessels. A training set of 109 low-dose MSCT scans made available by the Pisa center of the Italung-CT trial and annotated by expert radiologists was used for the algorithm design and optimization. The system performance was tested on an independent set of 23 low-dose MSCT scans coming from the Pisa Italung-CT center and on 83 scans made available by the Lung Image Database Consortium (LIDC) annotated by four expert radiologists. On the Italung-CT test set, for nodules having a diameter greater than or equal to 3 mm, the system achieved 84% and 71% sensitivity at false positive/scan rates of 10 and 4, respectively. For nodules having a diameter greater than or equal to 4 mm, the sensitivities were 97% and 80% at false positive/scan rates of 10 and 4, respectively. On the LIDC data set, the system achieved a 79% sensitivity at a false positive/scan rate of 4 in the detection of nodules with a diameter greater than or equal to 3 mm that have been annotated by all four radiologists.
Collapse
Affiliation(s)
- Bruno Golosio
- Struttura Dipartimentale di Matematica e Fisica, Università di Sassari, via Vienna 2, 07100 Sassari, Italy.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Imai K, Ikeda M, Enchi Y, Niimi T. Statistical characteristics of streak artifacts on CT images: Relationship between streak artifacts and mA s values. Med Phys 2009; 36:492-9. [DOI: 10.1118/1.3056554] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
16
|
Lee JY, Chung MJ, Yi CA, Lee KS. Ultra-low-dose MDCT of the chest: influence on automated lung nodule detection. Korean J Radiol 2008; 9:95-101. [PMID: 18385555 PMCID: PMC2627232 DOI: 10.3348/kjr.2008.9.2.95] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
OBJECTIVE To evaluate the relationship between CT dose and the performance of a computer-aided diagnosis (CAD) system, and to determine how best to minimize patient exposure to ionizing radiation while maintaining sufficient image quality for automated lung nodule detection, by the use of lung cancer screening CT. MATERIALS AND METHODS Twenty-five asymptomatic volunteers participated in the study. Each volunteer underwent a low-dose CT scan without contrast enhancement (multidetector CT with 16 detector rows, 1.25 mm section thickness, 120 kVp, beam pitch 1.35, 0.6 second rotation time, with 1.25 mm thickness reconstruction at 1.25 mm intervals) using four different amperages 32, 16, 8, and 4 mAs. All series were analyzed using a commercially available CAD system for automatic lung nodule detection and the results were reviewed by a consensus reading by two radiologists. The McNemar test and Kappa analysis were used to compare differences in terms of the abilities to detect pulmonary nodules. RESULTS A total of 78 non-calcified true nodules were visualized in the 25 study subjects. The sensitivities for nodule detection were as follows: 72% at 32 mAs, 64% at 16 mAs, 59% at 8 mAs, and 40% at 4 mAs. Although the overall nodule-detecting performance was best at 32 mAs, no significant difference in nodule detectability was observed between scans at 16 mAs or 8 mAs versus 32 mAs. However, scans performed at 4 mAs were significantly inferior to those performed at 32 mAs (p < 0.001). CONCLUSION Reducing the radiation dose (i.e. reducing the amperage) lowers lung nodule detectability by CAD. However, relatively low dose scans were found to be acceptable and to cause no significant reduction in nodule detectability versus usual low-dose CT.
Collapse
Affiliation(s)
- Ji Young Lee
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | | | | | | |
Collapse
|
17
|
Piriyakul R, Piamsa-Nga P. Feature Reduction in Graph Analysis. SENSORS (BASEL, SWITZERLAND) 2008; 8:4758-4773. [PMID: 27873784 PMCID: PMC3705470 DOI: 10.3390/s8084758] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/10/2008] [Revised: 08/07/2008] [Accepted: 08/07/2008] [Indexed: 06/06/2023]
Abstract
A common approach to improve medical image classification is to add more features to the classifiers; however, this increases the time required for preprocessing raw data and training the classifiers, and the increase in features is not always beneficial. The number of commonly used features in the literature for training of image feature classifiers is over 50. Existing algorithms for selecting a subset of available features for image analysis fail to adequately eliminate redundant features. This paper presents a new selection algorithm based on graph analysis of interactions among features and between features to classifier decision. A modification of path analysis is done by applying regression analysis, multiple logistic and posterior Bayesian inference in order to eliminate features that provide the same contributions. A database of 113 mammograms from the Mammographic Image Analysis Society was used in the experiments. Tested on two classifiers - ANN and logistic regression - cancer detection accuracy (true positive and false-positive rates) using a 13-feature set selected by our algorithm yielded substantially similar accuracy as using a 26-feature set selected by SFS and results using all 50-features. However, the 13-feature greatly reduced the amount of computation needed.
Collapse
Affiliation(s)
- Rapepun Piriyakul
- Department of Computer Engineering, Faculty of Engineering, Kasetsart University, Jatujak, Bangkok, 10900, Thailand.
| | - Punpiti Piamsa-Nga
- Department of Computer Engineering, Faculty of Engineering, Kasetsart University, Jatujak, Bangkok, 10900, Thailand.
| |
Collapse
|
18
|
Chan HP, Hadjiiski L, Zhou C, Sahiner B. Computer-aided diagnosis of lung cancer and pulmonary embolism in computed tomography-a review. Acad Radiol 2008; 15:535-55. [PMID: 18423310 PMCID: PMC2800985 DOI: 10.1016/j.acra.2008.01.014] [Citation(s) in RCA: 58] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2007] [Revised: 01/01/2008] [Accepted: 01/17/2008] [Indexed: 02/08/2023]
Abstract
Computer-aided detection (CADe) and computer-aided diagnosis (CADx) have been important areas of research in the last two decades. Significant progress has been made in the area of breast cancer detection, and CAD techniques are being developed in many other areas. Recent advances in multidetector row computed tomography have made it an increasingly common modality for imaging of lung diseases. A thoracic examination using thin-section computed tomography contains hundreds of images. Detection of lung cancer and pulmonary embolism on computed tomographic (CT) examinations are demanding tasks for radiologists because they have to search for abnormalities in a large number of images, and the lesions can be subtle. If successfully developed, CAD can be a useful second opinion to radiologists in thoracic CT interpretation. In this review, we summarize the studies that have been reported in these areas, discuss some challenges in the development of CAD, and identify areas that deserve particular attention in future research.
Collapse
Affiliation(s)
- Heang-Ping Chan
- Department of Radiology, Med Inn Building C477, 1500 East Medical Center Drive, The University of Michigan, Ann Arbor, MI 48109-5842, USA.
| | | | | | | |
Collapse
|
19
|
Wang P, DeNunzio A, Okunieff P, O'Dell WG. Lung metastases detection in CT images using 3D template matching. Med Phys 2007; 34:915-22. [PMID: 17441237 DOI: 10.1118/1.2436970] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
The aim of this study is to demonstrate a novel, fully automatic computer detection method applicable to metastatic tumors to the lung with a diameter of 4-20 mm in high-risk patients using typical computed tomography (CT) scans of the chest. Three-dimensional (3D) spherical tumor appearance models (templates) of various sizes were created to match representative CT imaging parameters and to incorporate partial volume effects. Taking into account the variability in the location of CT sampling planes cut through the spherical models, three offsetting template models were created for each appearance model size. Lung volumes were automatically extracted from computed tomography images and the correlation coefficients between the subregions around each voxel in the lung volume and the set of appearance models were calculated using a fast frequency domain algorithm. To determine optimal parameters for the templates, simulated tumors of varying sizes and eccentricities were generated and superposed onto a representative human chest image dataset. The method was applied to real image sets from 12 patients with known metastatic disease to the lung. A total of 752 slices and 47 identifiable tumors were studied. Spherical templates of three sizes (6, 8, and 10 mm in diameter) were used on the patient image sets; all 47 true tumors were detected with the inclusion of only 21 false positives. This study demonstrates that an automatic and straightforward 3D template-matching method, without any complex training or postprocessing, can be used to detect small lung metastases quickly and reliably in the clinical setting.
Collapse
Affiliation(s)
- Peng Wang
- Department of Biomedical Engineering, University of Rochester, Rochester, New York 14642, USA
| | | | | | | |
Collapse
|
20
|
Peloschek P, Sailer J, Weber M, Herold CJ, Prokop M, Schaefer-Prokop C. Pulmonary nodules: sensitivity of maximum intensity projection versus that of volume rendering of 3D multidetector CT data. Radiology 2007; 243:561-9. [PMID: 17456878 DOI: 10.1148/radiol.2432052052] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To prospectively compare maximum intensity projection (MIP) and volume rendering (VR) of multidetector computed tomographic (CT) data for the detection of small intrapulmonary nodules. MATERIALS AND METHODS This institutional review board-approved prospective study included 20 oncology patients (eight women and 12 men; mean age, 56 years +/- 16 [standard deviation]) who underwent clinically indicated standard-dose thoracic multidetector CT and provided informed consent. Transverse thin slabs of the chest (thickness, 7 mm; reconstruction increment, 3.5 mm) were created by using MIP and VR techniques to reconstruct CT data (collimation, 16 x 0.75 mm) and were reviewed in interactive cine mode. Mean, minimum, and maximum reading time per examination and per radiologist was documented. Three radiologists digitally annotated all nodules seen in a way that clearly determined their locations. The maximum number of nodules detected by the three observers and confirmed by consensus served as the reference standard. Descriptive statistics were calculated, with P < .05 indicating a significant difference. The Wilcoxon matched-pairs signed rank test and confidence intervals for differences between methods were used to compare the sensitivities of the two methods. RESULTS VR performed significantly better than MIP with regard to both detection rate (P < .001) and reporting time (P < .001). The superiority of VR was significant for all three observers and for nodules smaller than 11 mm in diameter and was pronounced for perihilar nodules (P = .023). Sensitivities achieved with VR ranged from 76.5% to 97.3%, depending on nodule size. CONCLUSION VR is the superior reading method compared with MIP for the detection of small solid intrapulmonary nodules.
Collapse
Affiliation(s)
- Philipp Peloschek
- Department of Radiology, Vienna Medical University, Währinger Gürtel 18-20, A-1090 Vienna, Austria; Department of Radiology, Utrecht Medical Center, Utrecht, the Netherlands
| | | | | | | | | | | |
Collapse
|
21
|
Bhatt S, Skwarski KM, Dogra VS. Recent Advances in Imaging for Lung Cancer. Lung Cancer 2007. [DOI: 10.3109/9781420020359.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
22
|
Abstract
OBJECTIVE The objective of this study was to assess the potential value of screening for occupational lung cancer through the use of low-dose computed tomography (LDCT). METHODS A literature review of Medline was conducted to assess: 1) screening studies of occupational lung cancer that used LDCT; 2) screening studies of nonoccupational lung cancer that used LDCT; and 3) position papers of medical professional societies and nongovernmental health organizations that have addressed the value of screening for lung cancer with LDCT. RESULTS No screening studies of occupational lung cancer with LDCT were uncovered; however, numerous observational and population-based studies have addressed the value of screening for lung cancer among cigarette smokers. Results of these studies are difficult to interpret in light of numerous biases associated with these types of studies. No randomized, controlled studies on screening for lung cancer have been published at this time. No professional, governmental, or nonprofit health organization recommends screening asymptomatic people at risk of lung cancer with LDCT at this time. CONCLUSION In the absence of randomized, controlled studies that can address biases commonly encountered in observational and population-based studies, it is unclear whether LDCT reduces mortality from lung cancer. The National Cancer Institute is sponsoring a randomized, controlled study of over 50,000 current and former smokers with the results expected in 2009.
Collapse
Affiliation(s)
- Robert J McCunney
- Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA.
| |
Collapse
|