1
|
Esposito M, Astolfo A, Cipiccia S, Jones CM, Savvidis S, Ferrara JD, Endrizzi M, Dudhia J, Olivo A. Technical note: Cartilage imaging with sub-cellular resolution using a laboratory-based phase-contrast x-ray microscope. Med Phys 2023; 50:6130-6136. [PMID: 37431640 PMCID: PMC10947188 DOI: 10.1002/mp.16599] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2023] [Revised: 05/10/2023] [Accepted: 06/12/2023] [Indexed: 07/12/2023] Open
Abstract
BACKGROUND Microscopic imaging of cartilage is a key tool for the study and development of treatments for osteoarthritis. When cellular and sub-cellular resolution is required, histology remains the gold standard approach, albeit limited by the lack of volumetric information as well as by processing artifacts. Cartilage imaging with the sub-cellular resolution has only been demonstrated in the synchrotron environment. PURPOSE To provide a proof-of-concept demonstration of the capability of a laboratory-based x-ray phase-contrast microscope to resolve sub-cellular features in a cartilage sample. METHODS This work is based on a laboratory-based x-ray microscope using intensity-modulation masks. The structured nature of the beam, resulting from the mask apertures, allows the retrieval of three contrast channels, namely, transmission, refraction and dark-field, with resolution depending only on the mask aperture width. An ex vivo equine cartilage sample was imaged with the x-ray microscope and results were validated with synchrotron tomography and histology. RESULTS Individual chondrocytes, that is, cells responsible for cartilage formation, could be detected with the laboratory-based microscope. The complementarity of the three retrieved contrast channels allowed the detection of sub-cellular features in the chondrocytes. CONCLUSIONS We provide the first proof-of-concept of imaging cartilage tissue with sub-cellular resolution using a laboratory-based x-ray microscope.
Collapse
Affiliation(s)
- Michela Esposito
- Department of Medical Physics and Biomedical EngineeringUniversity College LondonLondonUK
| | - Alberto Astolfo
- Department of Medical Physics and Biomedical EngineeringUniversity College LondonLondonUK
| | - Silvia Cipiccia
- Department of Medical Physics and Biomedical EngineeringUniversity College LondonLondonUK
- Diamond Light SourceHarwell Science and Innovation CampusDidcotUK
| | | | - Savvas Savvidis
- Department of Medical Physics and Biomedical EngineeringUniversity College LondonLondonUK
| | | | - Marco Endrizzi
- Department of Medical Physics and Biomedical EngineeringUniversity College LondonLondonUK
| | | | - Alessandro Olivo
- Department of Medical Physics and Biomedical EngineeringUniversity College LondonLondonUK
| |
Collapse
|
2
|
Guo Z, Levitan A, Barbastathis G, Comin R. Randomized probe imaging through deep k-learning. OPTICS EXPRESS 2022; 30:2247-2264. [PMID: 35209369 DOI: 10.1364/oe.445498] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Accepted: 12/22/2021] [Indexed: 06/14/2023]
Abstract
Randomized probe imaging (RPI) is a single-frame diffractive imaging method that uses highly randomized light to reconstruct the spatial features of a scattering object. The reconstruction process, known as phase retrieval, aims to recover a unique solution for the object without measuring the far-field phase information. Typically, reconstruction is done via time-consuming iterative algorithms. In this work, we propose a fast and efficient deep learning based method to reconstruct phase objects from RPI data. The method, which we call deep k-learning, applies the physical propagation operator to generate an approximation of the object as an input to the neural network. This way, the network no longer needs to parametrize the far-field diffraction physics, dramatically improving the results. Deep k-learning is shown to be computationally efficient and robust to Poisson noise. The advantages provided by our method may enable the analysis of far larger datasets in photon starved conditions, with important applications to the study of dynamic phenomena in physical science and biological engineering.
Collapse
|
3
|
X-ray fan beam coded aperture transmission and diffraction imaging for fast material analysis. Sci Rep 2021; 11:10585. [PMID: 34012075 PMCID: PMC8134570 DOI: 10.1038/s41598-021-90163-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Accepted: 04/26/2021] [Indexed: 02/03/2023] Open
Abstract
X-ray transmission imaging has been used in a variety of applications for high-resolution measurements based on shape and density. Similarly, X-ray diffraction (XRD) imaging has been used widely for molecular structure-based identification of materials. Combining these X-ray methods has the potential to provide high-resolution material identification, exceeding the capabilities of either modality alone. However, XRD imaging methods have been limited in application by their long measurement times and poor spatial resolution, which has generally precluded combined, rapid measurements of X-ray transmission and diffraction. In this work, we present a novel X-ray fan beam coded aperture transmission and diffraction imaging system, developed using commercially available components, for rapid and accurate non-destructive imaging of industrial and biomedical specimens. The imaging system uses a 160 kV Bremsstrahlung X-ray source while achieving a spatial resolution of ≈ 1 × 1 mm2 and a spectral accuracy of > 95% with only 15 s exposures per 150 mm fan beam slice. Applications of this technology are reported in geological imaging, pharmaceutical inspection, and medical diagnosis. The performance of the imaging system indicates improved material differentiation relative to transmission imaging alone at scan times suitable for a variety of industrial and biomedical applications.
Collapse
|
4
|
Abstract
Numerous advances have been made in X-ray technology in recent years. X-ray imaging plays an important role in the nondestructive exploration of the internal structures of objects. However, the contrast of X-ray absorption images remains low, especially for materials with low atomic numbers, such as biological samples. X-ray phase-contrast images have an intrinsically higher contrast than absorption images. In this review, the principles, milestones, and recent progress of X-ray phase-contrast imaging methods are demonstrated. In addition, prospective applications are presented.
Collapse
|
5
|
X-ray Dark-Field Imaging (XDFI)-a Promising Tool for 3D Virtual Histopathology. Mol Imaging Biol 2021; 23:481-494. [PMID: 33624229 DOI: 10.1007/s11307-020-01577-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Revised: 12/20/2020] [Accepted: 12/22/2020] [Indexed: 10/22/2022]
Abstract
X-ray dark-field imaging (XDFI) utilizing a thin silicon crystal under Laue case enables visualizing three-dimensional (3D) morphological alterations of human tissue. XDFI uses refraction-contrast derived from phase shift rather than absorption as the main X-ray image contrast source to render 2D and 3D images of tissue specimens in unprecedented detail. The unique features of XDFI are its extremely high sensitivity (approximately 1000:1 compared to absorption for soft tissues under X-ray energy of around 20 keV, theoretically) and excellent resolution (8.5 μm) without requiring contrast medium or staining. Thus, XDFI-computed tomography can generate 3D virtual histological images equivalent to those of stained histological sections pathologists observe under low-power light microscopy as far as organs and tissues selected as samples in preliminary studies. This paper reviews the fundamental principles and the potential of XDFI, describes two optical setups for XDFI with examples, illustrates features of XDFI that are salient for histopathology, and presents XDFI examples of refraction-contrast images of atherosclerotic plaques, musculoskeletal tissue, neuronal tissue, and breast cancer specimens. Availability of this X-ray imaging in routine histopathological evaluations of tissue specimens would help guide clinical decision making by highlighting suspicious areas in unstained, thick sections for further sampling and analysis using conventional histopathological techniques. XDFI is a promising tool for 3D virtual histopathology.
Collapse
|
6
|
Quantitative Assessment of Degenerative Cartilage and Subchondral Bony Lesions in a Preserved Cadaveric Knee: Propagation-Based Phase-Contrast CT Versus Conventional MRI and CT. AJR Am J Roentgenol 2018; 210:1317-1322. [PMID: 29629804 DOI: 10.2214/ajr.17.18286] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The aim of this study was to quantitatively assess hyaline cartilage and subchondral bone conditions in a fully preserved cadaveric human knee joint using high-resolution x-ray propagation-based phase-contrast imaging (PBI) CT and to compare the performance of the new technique with conventional CT and MRI. MATERIALS AND METHODS A cadaveric human knee was examined using an x-ray beam of 60 keV, a detector with a 90-mm2 FOV, and a pixel size of 46 × 46 μm2. PBI CT images were reconstructed with both the filtered back projection algorithm and the equally sloped tomography method. Conventional 3-T MRI and CT were also performed. Measurements of cartilage thickness, cartilage lesions, International Cartilage Repair Society scoring, and detection of subchondral bone changes were evaluated. Visual inspection of the specimen akin to arthroscopy was conducted and served as a standard of reference for lesion detection. RESULTS Loss of cartilage height was visible on PBI CT and MRI. Quantification of cartilage thickness showed a strong correlation between the two modalities. Cartilage lesions appeared darker than the adjacent cartilage on PBI CT. PBI CT showed similar agreement to MRI for depicting cartilage substance defects or lesions compared with the visual inspection. The assessment of subchondral bone cysts showed moderate to strong agreement between PBI CT and CT. CONCLUSION In contrast to the standard clinical methods of MRI and CT, PBI CT is able to simultaneously depict cartilage and bony changes at high resolution. Though still an experimental technique, PBI CT is a promising high-resolution imaging method to evaluate comprehensive changes of osteoarthritic disease in a clinical setting.
Collapse
|
7
|
Abstract
Unlike conventional x-ray attenuation one of the advantages of phase contrast x-ray imaging is its capability of extracting useful physical properties of the sample. In particular the possibility to obtain information from small angle scattering about unresolvable structures with sub-pixel resolution sensitivity has drawn attention for both medical and material science applications. We report on a novel algorithm for the analyzer based x-ray phase contrast imaging modality, which allows the robust separation of absorption, refraction and scattering effects from three measured x-ray images. This analytical approach is based on a simple Gaussian description of the analyzer transmission function and this method is capable of retrieving refraction and small angle scattering angles in the full angular range typical of biological samples. After a validation of the algorithm with a simulation code, which demonstrated the potential of this highly sensitive method, we have applied this theoretical framework to experimental data on a phantom and biological tissues obtained with synchrotron radiation. Owing to its extended angular acceptance range the algorithm allows precise assessment of local scattering distributions at biocompatible radiation doses, which in turn might yield a quantitative characterization tool with sufficient structural sensitivity on a submicron length scale.
Collapse
|
8
|
Synchrotron-Based in Situ Characterization of the Scaffold Mass Loss from Erosion Degradation. J Funct Biomater 2016; 7:jfb7030017. [PMID: 27399789 PMCID: PMC5040990 DOI: 10.3390/jfb7030017] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2016] [Revised: 06/13/2016] [Accepted: 06/23/2016] [Indexed: 11/29/2022] Open
Abstract
The mass loss behavior of degradable tissue scaffolds is critical to their lifespan and other degradation-related properties including mechanical strength and mass transport characteristics. This paper presents a novel method based on synchrotron imaging to characterize the scaffold mass loss from erosion degradation in situ, or without the need of extracting scaffolds once implanted. Specifically, the surface-eroding degradation of scaffolds in a degrading medium was monitored in situ by synchrotron-based imaging; and the time-dependent geometry of scaffolds captured by images was then employed to estimate their mass loss with time, based on the mathematical model that was adopted from the literature of surface erosion with the experimentally-identified model parameters. Acceptable agreement between experimental results and model predictions was observed for scaffolds in a cylindrical shape, made from poly(lactic-co-glycolic) acid (PLGA) and polycaprolactone (PCL). This study illustrates that geometry evaluation by synchrotron-based imaging is an effective means to in situ characterize the scaffold mass loss as well as possibly other degradation-related properties.
Collapse
|
9
|
Brun E, Grandl S, Sztrókay-Gaul A, Barbone G, Mittone A, Gasilov S, Bravin A, Coan P. Breast tumor segmentation in high resolution x-ray phase contrast analyzer based computed tomography. Med Phys 2014; 41:111902. [DOI: 10.1118/1.4896124] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
10
|
Horng A, Brun E, Mittone A, Gasilov S, Weber L, Geith T, Adam-Neumair S, Auweter SD, Bravin A, Reiser MF, Coan P. Cartilage and Soft Tissue Imaging Using X-rays. Invest Radiol 2014; 49:627-34. [DOI: 10.1097/rli.0000000000000063] [Citation(s) in RCA: 58] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
11
|
|
12
|
Marenzana M, Hagen CK, Borges PDN, Endrizzi M, Szafraniec MB, Vincent TL, Rigon L, Arfelli F, Menk RH, Olivo A. Synchrotron- and laboratory-based X-ray phase-contrast imaging for imaging mouse articular cartilage in the absence of radiopaque contrast agents. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2014; 372:20130127. [PMID: 24470419 PMCID: PMC3900037 DOI: 10.1098/rsta.2013.0127] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
The mouse model of osteoarthritis (OA) has been recognized as the most promising research tool for the identification of new OA therapeutic targets. However, this model is currently limited by poor throughput, dependent on the extremely time-consuming histopathology assessment of the articular cartilage (AC). We have recently shown that AC in the rat tibia can be imaged both in air and in saline solution using a laboratory system based on coded-aperture X-ray phase-contrast imaging (CAXPCi). Here, we explore ways to extend the methodology for imaging the much thinner AC of the mouse, by means of gold-standard synchrotron-based phase-contrast methods. Specifically, we have used analyser-based phase-contrast micro-computed tomography (micro-CT) for its high sensitivity to faint phase changes, coupled with a high-resolution (4.5 μm pixel) detector. Healthy, diseased (four weeks post induction of OA) and artificially damaged mouse AC was imaged at the Elettra synchrotron in Trieste, Italy, using the above method. For validation, we used conventional micro-CT combined with radiopaque soft-tissue staining and standard histomorphometry. We show that mouse cartilage can be visualized correctly by means of the synchrotron method. This suggests that: (i) further developments of the laboratory-based CAXPCi system, especially in terms of pushing the resolution limits, might have the potential to resolve mouse AC ex vivo and (ii) additional improvements may lead to a new generation of CAXPCi micro-CT scanners which could be used for in vivo longitudinal pre-clinical imaging of soft tissue at resolutions impossible to achieve by current MRI technology.
Collapse
Affiliation(s)
- Massimo Marenzana
- Department of Bioengineering, Imperial College, London SW7 2AZ, UK
- Kennedy Institute of Rheumatology, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford OX3 7HE, UK
| | - Charlotte K. Hagen
- Department of Medical Physics and Bioengineering, UCL, London WC1E 6BT, UK
| | | | - Marco Endrizzi
- Department of Medical Physics and Bioengineering, UCL, London WC1E 6BT, UK
| | | | - Tonia L. Vincent
- Kennedy Institute of Rheumatology, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford OX3 7HE, UK
| | - Luigi Rigon
- Dipartimento di Fisica dell'Università degli Studi di Trieste, Via Valerio 2, Trieste 34100, Italy
| | - Fulvia Arfelli
- Dipartimento di Fisica dell'Università degli Studi di Trieste, Via Valerio 2, Trieste 34100, Italy
| | - Ralf-Hendrik Menk
- Sincrotrone Trieste SCpA, Strada Statale, Basovizza, Trieste 34149, Italy
| | - Alessandro Olivo
- Department of Medical Physics and Bioengineering, UCL, London WC1E 6BT, UK
| |
Collapse
|
13
|
Bravin A, Coan P, Suortti P. X-ray phase-contrast imaging: from pre-clinical applications towards clinics. Phys Med Biol 2012; 58:R1-35. [PMID: 23220766 DOI: 10.1088/0031-9155/58/1/r1] [Citation(s) in RCA: 391] [Impact Index Per Article: 32.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Phase-contrast x-ray imaging (PCI) is an innovative method that is sensitive to the refraction of the x-rays in matter. PCI is particularly adapted to visualize weakly absorbing details like those often encountered in biology and medicine. In past years, PCI has become one of the most used imaging methods in laboratory and preclinical studies: its unique characteristics allow high contrast 3D visualization of thick and complex samples even at high spatial resolution. Applications have covered a wide range of pathologies and organs, and are more and more often performed in vivo. Several techniques are now available to exploit and visualize the phase-contrast: propagation- and analyzer-based, crystal and grating interferometry and non-interferometric methods like the coded aperture. In this review, covering the last five years, we will give an overview of the main theoretical and experimental developments and of the important steps performed towards the clinical implementation of PCI.
Collapse
Affiliation(s)
- Alberto Bravin
- European Synchrotron Radiation Facility, 6 rue Horowitz, 38043 Grenoble Cedex, France.
| | | | | |
Collapse
|
14
|
Marenzana M, Hagen CK, Das Neves Borges P, Endrizzi M, Szafraniec MB, Ignatyev K, Olivo A. Visualization of small lesions in rat cartilage by means of laboratory-based x-ray phase contrast imaging. Phys Med Biol 2012; 57:8173-84. [PMID: 23174992 DOI: 10.1088/0031-9155/57/24/8173] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Being able to quantitatively assess articular cartilage in three-dimensions (3D) in small rodent animal models, with a simple laboratory set-up, would prove extremely important for the development of pre-clinical research focusing on cartilage pathologies such as osteoarthritis (OA). These models are becoming essential tools for the development of new drugs for OA, a disease affecting up to 1/3 of the population older than 50 years for which there is no cure except prosthetic surgery. However, due to limitations in imaging technology, high-throughput 3D structural imaging has not been achievable in small rodent models, thereby limiting their translational potential and their efficiency as research tools. We show that a simple laboratory system based on coded-aperture x-ray phase contrast imaging (CAXPCi) can correctly visualize the cartilage layer in slices of an excised rat tibia imaged both in air and in saline solution. Moreover, we show that small, surgically induced lesions are also correctly detected by the CAXPCi system, and we support this finding with histopathology examination. Following these successful proof-of-concept results in rat cartilage, we expect that an upgrade of the system to higher resolutions (currently underway) will enable extending the method to the imaging of mouse cartilage as well. From a technological standpoint, by showing the capability of the system to detect cartilage also in water, we demonstrate phase sensitivity comparable to other lab-based phase methods (e.g. grating interferometry). In conclusion, CAXPCi holds a strong potential for being adopted as a routine laboratory tool for non-destructive, high throughput assessment of 3D structural changes in murine articular cartilage, with a possible impact in the field similar to the revolution that conventional microCT brought into bone research.
Collapse
|
15
|
Li J, Wilson N, Zelazny A, Meyer J, Zhong Z, Muehleman C. Assessment of diffraction-enhanced synchrotron imaging for cartilage degeneration of the human knee joint. Clin Anat 2012; 26:621-9. [DOI: 10.1002/ca.22106] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2011] [Revised: 05/01/2012] [Accepted: 05/04/2012] [Indexed: 11/09/2022]
Affiliation(s)
- J. Li
- Department of Biochemistry; Rush University Medical Center; Chicago; Illinois
| | - N. Wilson
- Department of Biochemistry; Rush University Medical Center; Chicago; Illinois
| | - A. Zelazny
- Department of Radiology; Rush University Medical Center; Chicago; Illinois
| | - J. Meyer
- Department of Radiology; Rush University Medical Center; Chicago; Illinois
| | - Z. Zhong
- National Synchrotron Light Source; Brookhaven National Laboratory; Upton; New York
| | | |
Collapse
|
16
|
Connor DM, Zhong Z, Foda HD, Wiebe S, Parham CA, Dilmanian FA, Cole EB, Pisano ED. Diffraction enhanced imaging of a rat model of gastric acid aspiration pneumonitis. Acad Radiol 2011; 18:1515-21. [PMID: 21958600 DOI: 10.1016/j.acra.2011.08.005] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2011] [Revised: 08/09/2011] [Accepted: 08/09/2011] [Indexed: 11/28/2022]
Abstract
RATIONALE AND OBJECTIVES Diffraction-enhanced imaging (DEI) is a type of phase contrast x-ray imaging that has improved image contrast at a lower dose than conventional radiography for many imaging applications, but no studies have been done to determine if DEI might be useful for diagnosing lung injury. The goals of this study were to determine if DEI could differentiate between healthy and injured lungs for a rat model of gastric aspiration and to compare diffraction-enhanced images with chest radiographs. MATERIALS AND METHODS Radiographs and diffraction-enhanced chest images of adult Sprague Dawley rats were obtained before and 4 hours after the aspiration of 0.4 mL/kg of 0.1 mol/L hydrochloric acid. Lung damage was confirmed with histopathology. RESULTS The radiographs and diffraction-enhanced peak images revealed regions of atelectasis in the injured rat lung. The diffraction-enhanced peak images revealed the full extent of the lung with improved clarity relative to the chest radiographs, especially in the portion of the lower lobe that extended behind the diaphragm on the anteroposterior projection. CONCLUSIONS For a rat model of gastric acid aspiration, DEI is capable of distinguishing between a healthy and an injured lung and more clearly than radiography reveals the full extent of the lung and the lung damage.
Collapse
Affiliation(s)
- Dean M Connor
- Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC 29425, USA.
| | | | | | | | | | | | | | | |
Collapse
|
17
|
Stutman D, Beck TJ, Carrino JA, Bingham CO. Talbot phase-contrast x-ray imaging for the small joints of the hand. Phys Med Biol 2011; 56:5697-720. [PMID: 21841214 PMCID: PMC3166798 DOI: 10.1088/0031-9155/56/17/015] [Citation(s) in RCA: 87] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
A high-resolution radiographic method for soft tissues in the small joints of the hand would aid in the study and treatment of rheumatoid arthritis (RA) and osteoarthritis (OA), which often attacks these joints. Of particular interest would be imaging with <100 µm resolution the joint cartilage, whose integrity is a main indicator of disease. Differential phase-contrast (DPC) or refraction-based x-ray imaging with Talbot grating interferometers could provide such a method, since it enhances soft tissue contrast and can be implemented with conventional x-ray tubes. A numerical joint phantom was first developed to assess the angular sensitivity and spectrum needed for a hand DPC system. The model predicts that, due to quite similar refraction indexes for joint soft tissues, the refraction effects are very small, requiring high angular resolution. To compare our model to experiment we built a high-resolution bench-top interferometer using 10 µm period gratings, a W anode tube and a CCD-based detector. Imaging experiments on animal cartilage and on a human finger support the model predictions. For instance, the estimated difference between the index of refraction of cartilage and water is of only several percent at ∼25 keV mean energy, comparable to that between the linear attenuation coefficients. The potential advantage of DPC imaging thus comes mainly from the edge enhancement at the soft tissue interfaces. Experiments using a cadaveric human finger are also qualitatively consistent with the joint model, showing that refraction contrast is dominated by tendon embedded in muscle, with the cartilage layer difficult to observe in our conditions. Nevertheless, the model predicts that a DPC radiographic system for the small hand joints of the hand could be feasible using a low energy quasi-monochromatic source, such as a K-edge filtered Rh or Mo tube, in conjunction with a ∼2 m long 'symmetric' interferometer operated in a high Talbot order.
Collapse
Affiliation(s)
- Dan Stutman
- Department of Physics and Astronomy, Johns Hopkins University, Baltimore, MD 21218, USA.
| | | | | | | |
Collapse
|
18
|
Kemble CK, Auxier J, Lynch SK, Bennett EE, Morgan NY, Wen H. Grazing angle Mach-Zehnder interferometer using reflective phase gratings and a polychromatic, un-collimated light source. OPTICS EXPRESS 2010; 18:27481-92. [PMID: 21197023 PMCID: PMC3088511 DOI: 10.1364/oe.18.027481] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Normal incidence Talbot-Lau interferometers in x-ray applications have the drawbacks of low fringe visibility with polychromatic sources when the wave propagation distance is increased to achieve higher phase sensitivity, and when fabrication limits the attainable grating density. In contrast, reflective gratings illuminated at grazing angles have dramatically higher effective densities than their physical values. However, new designs are needed for far field interferometers using grazing angle geometry with incoherent light sources. We show that, with the appropriate design and choice of reflective phase gratings, there exist pairs of interfering pathways of exactly equal lengths independent of the incoming beam's incidence angle and wavelength. With a visible light grazing angle Mach-Zehnder interferometer, we show the conditions for achieving near ideal fringe visibility and demonstrate both absolute and differential phase-contrast imaging. We also describe the design parameters of an x-ray interferometer and key factors for its implementation.
Collapse
Affiliation(s)
- Camille K. Kemble
- Imaging Physics Section, National Heart, Lung and Blood Institute, Bethesda, MD, 20892, USA
| | - Julie Auxier
- Intramural Research Programs,National Institute of Biomedical Imaging and Bioengineering National Institutes of Health, Bethesda, MD, 20892, USA
| | - Susanna K. Lynch
- Imaging Physics Section, National Heart, Lung and Blood Institute, Bethesda, MD, 20892, USA
| | - Eric E. Bennett
- Imaging Physics Section, National Heart, Lung and Blood Institute, Bethesda, MD, 20892, USA
| | - Nicole Y. Morgan
- Intramural Research Programs,National Institute of Biomedical Imaging and Bioengineering National Institutes of Health, Bethesda, MD, 20892, USA
| | - Han Wen
- Imaging Physics Section, National Heart, Lung and Blood Institute, Bethesda, MD, 20892, USA
| |
Collapse
|
19
|
Muehleman C, Fogarty D, Reinhart B, Tzvetkov T, Li J, Nesch I. In-laboratory diffraction-enhanced X-ray imaging for articular cartilage. Clin Anat 2010; 23:530-8. [PMID: 20544949 DOI: 10.1002/ca.20993] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The loss of articular cartilage characteristic of osteoarthritis can only be diagnosed by joint space narrowing when conventional radiography is used. This is due to the lack of X-ray contrast of soft tissues. Whereas conventional radiography harnesses the X-ray attenuation properties of tissues, Diffraction Enhanced Imaging (DEI), a novel radiographic technique, allows the visualization of soft tissues simultaneous with calcified tissues by virtue of its ability to not only harness X-ray attenuation but also the X-ray refraction from tissue boundaries. Previously, DEI was dependent upon synchrotron X-rays, but more recently, the development of nonsynchrotron DEI units has been explored. These developments serve to elaborate the full potential of radiography. Here, we tested the potential of an in-laboratory DEI system, called Diffraction-Enhanced X-ray Imaging (DEXI), to render images of articular cartilage displaying varying degrees of degradation, ex vivo. DEXI allowed visualization of even early stages of cartilage degeneration such as surface fibrillation. This may be of eventual clinical significance for the diagnosis of early stages of degeneration, or at the very least, to visualize soft tissue degeneration simultaneous with bone changes.
Collapse
Affiliation(s)
- Carol Muehleman
- Department of Biochemistry, Rush University Medical Center, 1735 W. Harrison Street, Chicago, IL 60612, USA.
| | | | | | | | | | | |
Collapse
|
20
|
Stutman D, Finkenthal M, Moldovan N. Development of microperiodic mirrors for hard x-ray phase-contrast imaging. APPLIED OPTICS 2010; 49:4677-4686. [PMID: 20820208 DOI: 10.1364/ao.49.004677] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Differential phase-contrast imaging with hard x rays can have important applications in medicine, material sciences, and energy research. Phase-contrast methods based on microperiodic optics, such as shearing interferometry, are particularly attractive because they allow the use of conventional x-ray tubes. To enable shearing interferometry with x rays up to 100?keV, we propose using grazing-incidence microperiodic mirrors. In addition, a simple lithographic method is proposed for the production of the microperiodic x-ray mirrors, based on the difference in grazing-incidence reflectivity between a low-Z substrate and a high-Z film. Using this method, we produced prototype mirrors with 5-100?mum periods and 90?mm active length. Experimental tests with x rays up to 60?keV indicate good microperiodic mirror reflectivity and high-contrast fringe patterns, encouraging further development of the proposed imaging concept.
Collapse
Affiliation(s)
- Dan Stutman
- Department of Physics and Astronomy, Johns Hopkins University, Baltimore, Maryland 21030, USA.
| | | | | |
Collapse
|
21
|
Cooper DML, Bewer B, Wiebe S, Wysokinski TW, Chapman D. Diffraction enhanced X-ray imaging of the distal radius: a novel approach for visualization of trabecular bone architecture. Can Assoc Radiol J 2010; 62:251-5. [PMID: 20591611 DOI: 10.1016/j.carj.2010.04.015] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2010] [Revised: 04/27/2010] [Accepted: 04/29/2010] [Indexed: 10/19/2022] Open
Affiliation(s)
- David M L Cooper
- Department of Anatomy and Cell Biology, University of Saskatchewan, Saskatoon, Saskatchewan, Canada.
| | | | | | | | | |
Collapse
|
22
|
Characterization of Osteoarthritic and Normal Human Patella Cartilage by Computed Tomography X-ray Phase-Contrast Imaging. Invest Radiol 2010; 45:437-44. [DOI: 10.1097/rli.0b013e3181e193bd] [Citation(s) in RCA: 57] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
23
|
Chen GH, Bevins N, Zambelli J, Qi Z. Small-angle scattering computed tomography (SAS-CT) using a Talbot-Lau interferometerand a rotating anode x-ray tube:theory and experiments. OPTICS EXPRESS 2010; 18:12960-70. [PMID: 20588425 PMCID: PMC3746741 DOI: 10.1364/oe.18.012960] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
X-ray differential phase contrast imaging methods, including projection imaging and the corresponding computed tomography (CT), have been implemented using a Talbot interferometer and either a synchrotron beam line or a low brilliance x-ray source generated by a stationary-anode x-ray tube. From small-angle scattering events which occur as an x-ray propagates through a medium, a signal intensity loss can be recorded and analyzed for an understanding of the micro-structures in an image object. This has been demonstrated using a Talbot-Lau interferometer and a stationary-anode x-ray tube. In this paper, theoretical principles and an experimental implementation of the corresponding CT imaging method are presented. First, a line integral is derived from analyzing the cross section of the small-angle scattering events. This method is referred to as small-angle scattering computed tomography (SAS-CT). Next, a Talbot-Lau interferometer and a rotating-anode x-ray tube were used to implement SAS-CT. A physical phantom and human breast tissue sample were used to demonstrate the reconstructed SAS-CT image volumes.
Collapse
Affiliation(s)
- Guang-Hong Chen
- Department of Medical Physics, University of Wisconsin-Madison, WI 53705, USA.
| | | | | | | |
Collapse
|
24
|
Chen GH, Zambelli J, Bevins N, Qi Z, Li K. X-ray phase sensitive imaging methods: basic physical principles and potential medical applications. Curr Med Imaging 2010; 6:90-99. [PMID: 23970846 DOI: 10.2174/157340510791268533] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Phase sensitive imaging theoretically allows for a drastic reduction in x-ray dose while simultaneously achieving comparable or better spatial and contrast resolution compared to traditional x-ray absorption based imaging. Several techniques exist to extract the phase information from an x-ray signal, including x-ray interferometry, diffraction enhanced imaging, in-line holography, coded aperture x-ray imaging, and grating-based interferometry. The physics of each method is reviewed, along with the potential clinical applications.
Collapse
Affiliation(s)
- Guang-Hong Chen
- Department of Medical Physics, University of Wisconsin-Madison. Department of Radiology, University of Wisconsin-Madison
| | | | | | | | | |
Collapse
|
25
|
Lee YS, Heo EA, Jun HY, Kang SH, Kim HS, Lee MS, Byun SJ, Lee SH, Park SH, Yoon KH. Articular cartilage imaging by the use of phase-contrast tomography in a collagen-induced arthritis mouse model. Acad Radiol 2010; 17:244-50. [PMID: 19962916 DOI: 10.1016/j.acra.2009.09.015] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2009] [Revised: 09/11/2009] [Accepted: 09/11/2009] [Indexed: 10/20/2022]
Abstract
RATIONALE AND OBJECTIVES This study was designed to demonstrate the feasibility of the use of phase-contrast computed tomographic (CT) imaging for the identification of articular cartilage abnormalities of the knees in a mouse model of collagen-induced arthritis. MATERIALS AND METHODS Arthritis was induced in nine male DBA/1 J mice by the intradermal injection of collagen. After 50 days, the nine mice were sacrificed, along with four mice that did not receive intradermal injections of collagen. Phase-contrast CT imaging using a microfocus x-ray source of the entire knee was performed. The images were evaluated by two blinded readers, and histopathologic grades were considered the reference standard. The phase-contrast CT images of cartilage were graded 0, I, or II. Evaluation of the grading agreement between the phase-contrast CT images and histopathologic findings was performed using correlation analysis. RESULTS Phase-contrast CT images highly reflected the subchondral bone status in the assessment of articular cartilage abnormalities in the mouse model of collagen-induced arthritis. Three-dimensional reformed images showed the articular surface and subchondral bony status of the knee joints. On the basis of the histopathology of the 26 knee joints, 12 joints were grade 0, six joints were grade I, and eight joints were grade II. Grading agreement between the use of the phase-contrast CT images and histopathologic results was high (r = 0.76). CONCLUSIONS Phase-contrast CT imaging using a microfocus x-ray source offers a promising tool for the assessment of articular cartilage abnormalities of the knees in a mouse model.
Collapse
|