1
|
Ageeli W, Soha N, Zhang X, Szewcyk-Bieda M, Wilson J, Li C, Nabi G. Preoperative imaging accuracy in size determination of prostate cancer in men undergoing radical prostatectomy for clinically localised disease. Insights Imaging 2023; 14:105. [PMID: 37286770 DOI: 10.1186/s13244-023-01450-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2022] [Accepted: 03/06/2023] [Indexed: 06/09/2023] Open
Abstract
OBJECTIVES To compare the accuracy of pre-surgical prostate size measurements using mpMRI and USWE with imaging-based 3D-printed patient-specific whole-mount moulds facilitated histopathology, and to assess whether size assessment varies between clinically significant and non-significant cancerous lesions including their locations in different zones of the prostate. METHODS The study population included 202 men with clinically localised prostate cancer opting for radical surgery derived from two prospective studies. Protocol-based imaging data was used for measurement of size of prostate cancer in clinically localised disease using MRI (N = 106; USWE (N = 96). Forty-eight men overlapped between two studies and formed the validation cohort. The primary outcome of this study was to assess the accuracy of pre-surgical prostate cancerous size measurements using mpMRI and USWE with imaging-based 3D-printed patient-specific whole-mount moulds facilitated histopathology as a reference standard. Independent-samples T-tests were used for the continuous variables and a nonparametric Mann-Whitney U test for independent samples was applied to examine the distribution and median differences between mpMRI and USWE groups. RESULTS A significant number of men had underestimation of prostate cancer using both mpMRI (82.1%; 87/106) and USWE (64.6%; 62/96). On average, tumour size was underestimated by a median size of 7 mm in mpMRI, and 1 mm in USWE. There were 327 cancerous lesions (153 with mpMRI and 174 for USWE). mpMRI and USWE underestimated the majority of cancerous lesions (108/153; 70.6%) and (88/174; 50.6%), respectively. Validation cohort data confirmed these findings MRI had a nearly 20% higher underestimation rate than USWE (χ2 (1, N = 327) = 13.580, p = 0.001); especially in the mid and apical level of the gland. Clinically non-significant cancers were underestimated in significantly higher numbers in comparison to clinically significant cancers. CONCLUSIONS Size measurement of prostate cancers on preoperative imaging utilising maximum linear extent technique, underestimated the extent of cancer. Further research is needed to confirm our observations using different sequences, methods and approaches for cancer size measurement.
Collapse
Affiliation(s)
- Wael Ageeli
- Division of Imaging Sciences and Technology, School of Medicine, University of Dundee, Ninewells Hospital, Dundee, DD1 9SY, UK
- Diagnostic Radiology Department, College of Applied Medical Sciences, Jazan University, Al Maarefah Rd, P.O. Box 114, Jazan, 45142, Saudi Arabia
| | - Nabi Soha
- Division of Imaging Sciences and Technology, School of Medicine, University of Dundee, Ninewells Hospital, Dundee, DD1 9SY, UK
| | - Xinyu Zhang
- Division of Population Health and Genomics, School of Medicine, University of Dundee, Dundee, DD1 9SY, UK
| | | | - Jennifer Wilson
- Department of Pathology, Ninewells Hospital, Dundee, DD1 9SY, UK
| | - Chunhui Li
- School of Science and Engineering, University of Dundee, Dundee, DD1 4HN, UK
| | - Ghulam Nabi
- Division of Imaging Sciences and Technology, School of Medicine, University of Dundee, Ninewells Hospital, Dundee, DD1 9SY, UK.
| |
Collapse
|
2
|
Bahler CD, Green MA, Tann MA, Swensson JK, Collins K, Alexoff D, Kung H, Brocken E, Mathias CJ, Cheng L, Hutchins GD, Koch MO. Assessing extra-prostatic extension for surgical guidance in prostate cancer: Comparing two PSMA-PET tracers with the standard-of-care. Urol Oncol 2023; 41:48.e1-48.e9. [PMID: 36333187 DOI: 10.1016/j.urolonc.2022.10.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 09/20/2022] [Accepted: 10/03/2022] [Indexed: 11/06/2022]
Abstract
BACKGROUND Incontinence and impotence occur following radical prostatectomy due to injury to nerves and sphincter muscle. Preserving nerves and muscle adjacent to prostate cancer risks positive surgical margins. Advanced imaging with MRI has improved cancer localization but limitations exist. OBJECTIVE To measure the accuracy for assessing extra-prostatic extension at nerve bundles for 2 PSMA-PET tracers and to compare the PET accuracy to standard-of-care predictors including MRI and biopsy results. MATERIALS AND METHODS We studied men with PSMA-targeted PET imaging, performed prior to prostatectomy in men largely with intermediate to high-risk prostate cancer, and retrospectively evaluated for assessment of extra-prostatic extension with whole-mount analysis as reference standard. Two different PSMA-PET tracers were included: 68Ga-PSMA-11 and 68Ga-P16-093. Blinded reviews of the PET and MRI scans were performed to assess extra-prostatic extension (EPE). Sensitivity and specificity for extra-prostatic extension were compared using McNemar's Chi2. RESULTS Pre-operative PSMA-PET imaging was available for 71 patients with either 68Ga-P16-093 (n = 25) or 68Ga-PSMA-11 (n = 46). There were 24 (34%) with pT3a (EPE) and 16 (23%) with pT3b (SVI). EPE Sensitivity (87% vs. 92%), Specificity (77% vs. 76%), and ROC area (0.82 vs. 0.84) were similar between P16-093 and PSMA-11, respectively (P = 0.87). MRI (available in only 45) found high specificity (83%) but low sensitivity (60%) for EPE when using a published grading system. MRI sensitivity was significantly lower than the PSMA-PET (60% vs. 90%, P = 0.02), but similar to PET when using a >5 mm capsular contact (76% vs. 90%, P = 0.38). A treatment change to "nerve sparing" was recommended in 21 of 71 (30%) patients based on PSMA-PET imaging. CONCLUSIONS Presurgical PSMA-PET appeared useful as a tool for surgical planning, changing treatment plans in men with ≥4+3 or multi-core 3+4 prostate cancer resulting in preservation of nerve-bundles.
Collapse
Affiliation(s)
| | - Mark A Green
- Indiana University, Department of Radiology and Imaging Sciences, Indianapolis, IN
| | - Mark A Tann
- Indiana University, Department of Radiology and Imaging Sciences, Indianapolis, IN
| | | | - Katrina Collins
- Indiana University, Department of Pathology, Indianapolis, IN
| | | | - Hank Kung
- University of Pennsylvania, Department of Radiology, Philadelphia, PA
| | - Eric Brocken
- Indiana University, Department of Pathology, Indianapolis, IN
| | - Carla J Mathias
- Indiana University, Department of Radiology and Imaging Sciences, Indianapolis, IN
| | - Liang Cheng
- Indiana University, Department of Pathology, Indianapolis, IN
| | - Gary D Hutchins
- Indiana University, Department of Radiology and Imaging Sciences, Indianapolis, IN
| | - Michael O Koch
- Indiana University, Department of Urology, Indianapolis, IN
| |
Collapse
|
3
|
Accurate validation of ultrasound imaging of prostate cancer: a review of challenges in registration of imaging and histopathology. J Ultrasound 2018; 21:197-207. [PMID: 30062440 PMCID: PMC6113189 DOI: 10.1007/s40477-018-0311-8] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2018] [Accepted: 07/11/2018] [Indexed: 01/20/2023] Open
Abstract
As the development of modalities for prostate cancer (PCa) imaging advances, the challenge of accurate registration between images and histopathologic ground truth becomes more pressing. Localization of PCa, rather than detection, requires a pixel-to-pixel validation of imaging based on histopathology after radical prostatectomy. Such a registration procedure is challenging for ultrasound modalities; not only the deformations of the prostate after resection have to be taken into account, but also the deformation due to the employed transrectal probe and the mismatch in orientation between imaging planes and pathology slices. In this work, we review the latest techniques to facilitate accurate validation of PCa localization in ultrasound imaging studies and extrapolate a general strategy for implementation of a registration procedure.
Collapse
|
4
|
Priester A, Wu H, Khoshnoodi P, Schneider D, Zhang Z, Asvadi NH, Sisk A, Raman S, Reiter R, Grundfest W, Marks LS, Natarajan S. Registration Accuracy of Patient-Specific, Three-Dimensional-Printed Prostate Molds for Correlating Pathology With Magnetic Resonance Imaging. IEEE Trans Biomed Eng 2018; 66:14-22. [PMID: 29993431 DOI: 10.1109/tbme.2018.2828304] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
OBJECTIVE This investigation was performed to evaluate the registration accuracy between magnetic resonance imaging (MRI) and pathology using three-dimensional (3-D) printed molds. METHODS Tissue-mimicking prostate phantoms were manufactured with embedded fiducials. The fiducials were used to measure and compare target registration error (TRE) between phantoms that were sliced by hand versus phantoms that were sliced within 3-D-printed molds. Subsequently, ten radical prostatectomy specimens were placed inside molds, scanned with MRI, and then sliced. The ex vivo scan was used to assess the true location of whole mount (WM) slides relative to in vivo MRI. The TRE between WM and in vivo MRI was measured using anatomic landmarks. RESULTS Manually sliced phantoms had a 4.1-mm mean TRE, whereas mold-sliced phantoms had a 1.9-mm mean TRE. Similarly, mold-assisted slicing reduced mean angular misalignment around the left-right (LR) anatomic axis from 10.7° to 4.5°. However, ex vivo MRI revealed that excised prostates were misaligned within molds, including a mean 14° rotation about the LR axis. The mean in-plane TRE was 3.3 mm using molds alone and 2.2 mm after registration was corrected with ex vivo MRI. CONCLUSION Patient-specific molds improved accuracy relative to manual slicing techniques in a phantom model. However, the registration accuracy of surgically resected specimens was limited by their imperfect fit within molds. This limitation can be overcome with the addition of ex vivo imaging. SIGNIFICANCE The accuracy of 3-D-printed molds was characterized, quantifying their utility for facilitating MRI-pathology registration.
Collapse
|
5
|
Wildeboer RR, Schalk SG, Demi L, Wijkstra H, Mischi M. Three-dimensional histopathological reconstruction as a reliable ground truth for prostate cancer studies. Biomed Phys Eng Express 2017. [DOI: 10.1088/2057-1976/aa7073] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
6
|
Priester A, Natarajan S, Khoshnoodi P, Margolis DJ, Raman SS, Reiter RE, Huang J, Grundfest W, Marks LS. Magnetic Resonance Imaging Underestimation of Prostate Cancer Geometry: Use of Patient Specific Molds to Correlate Images with Whole Mount Pathology. J Urol 2016; 197:320-326. [PMID: 27484386 DOI: 10.1016/j.juro.2016.07.084] [Citation(s) in RCA: 169] [Impact Index Per Article: 21.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/26/2016] [Indexed: 02/08/2023]
Abstract
PURPOSE We evaluated the accuracy of magnetic resonance imaging in determining the size and shape of localized prostate cancer. MATERIALS AND METHODS The subjects were 114 men who underwent multiparametric magnetic resonance imaging before radical prostatectomy with patient specific mold processing of the specimen from 2013 to 2015. T2-weighted images were used to contour the prostate capsule and cancer suspicious regions of interest. The contours were used to design and print 3-dimensional custom molds, which permitted alignment of excised prostates with magnetic resonance imaging scans. Tumors were reconstructed in 3 dimensions from digitized whole mount sections. Tumors were then matched with regions of interest and the relative geometries were compared. RESULTS Of the 222 tumors evident on whole mount sections 118 had been identified on magnetic resonance imaging. For the 118 regions of interest mean volume was 0.8 cc and the longest 3-dimensional diameter was 17 mm. However, for matched pathological tumors, of which most were Gleason score 3 + 4 or greater, mean volume was 2.5 cc and the longest 3-dimensional diameter was 28 mm. The median tumor had a 13.5 mm maximal extent beyond the magnetic resonance imaging contour and 80% of cancer volume from matched tumors was outside region of interest boundaries. Size estimation was most accurate in the axial plane and least accurate along the base-apex axis. CONCLUSIONS Magnetic resonance imaging consistently underestimates the size and extent of prostate tumors. Prostate cancer foci had an average diameter 11 mm longer and a volume 3 times greater than T2-weighted magnetic resonance imaging segmentations. These results may have important implications for the assessment and treatment of prostate cancer.
Collapse
Affiliation(s)
- Alan Priester
- Department of Bioengineering, University of California Los Angeles, Los Angeles, California
| | - Shyam Natarajan
- Department of Urology, David Geffen School of Medicine at UCLA, University of California Los Angeles, Los Angeles, California; Department of Bioengineering, University of California Los Angeles, Los Angeles, California
| | - Pooria Khoshnoodi
- Department of Radiological Sciences, David Geffen School of Medicine at UCLA, University of California Los Angeles, Los Angeles, California
| | - Daniel J Margolis
- Department of Radiological Sciences, David Geffen School of Medicine at UCLA, University of California Los Angeles, Los Angeles, California
| | - Steven S Raman
- Department of Radiological Sciences, David Geffen School of Medicine at UCLA, University of California Los Angeles, Los Angeles, California
| | - Robert E Reiter
- Department of Urology, David Geffen School of Medicine at UCLA, University of California Los Angeles, Los Angeles, California
| | - Jiaoti Huang
- Department of Pathology, Duke University School of Medicine, Durham, North Carolina
| | - Warren Grundfest
- Department of Bioengineering, University of California Los Angeles, Los Angeles, California
| | - Leonard S Marks
- Department of Urology, David Geffen School of Medicine at UCLA, University of California Los Angeles, Los Angeles, California.
| |
Collapse
|
7
|
Commandeur F, Acosta O, Simon A, Mathieu R, Fautrel A, Gnep K, Haigron P, de Crevoisier R. Prostate whole-mount histology reconstruction and registration to MRI for correlating in-vivo observations with biological findings. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2015:2399-2402. [PMID: 26736777 DOI: 10.1109/embc.2015.7318877] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Multi-parametric magnetic resonance imaging (mMRI) is the standard exam for prostate cancer diagnosis, staging and risk assessment in current clinical routine. Correlating mMRI in-vivo observations with biological findings from radical prostatectomy specimen would improve the optimal therapy selection. Thus, we proposed a method for reconstructing and registering the prostate whole-mount histology (WMH) to the MRI, considering a thin slicing of the prostatectomy specimen. The method was evaluated on 3 patients, included in a prospective study, for which hematein-eosinsafran and immunohistochemistry stainings were performed. The registration error was assessed by measuring the Euclidean distance between landmarks, previously identified by an expert on both mMRI and histological slices. The mean error was 4:90α1:34 mm. Our method demonstrated promising results for registering prostate WMH to in-vivo mMRI, thus allowing for spatial accurate correlation between radiologic observations and biological information.
Collapse
|