1
|
Sun YX, Shang J, Cui Y, Zhang KJ, Li XT, Li DN, Gu XL, Tian XY, Sun N, Zhang L, You MN, Zhang XY, Sun YS. Impact of different concentration iodinated contrast media on pain and comfort in abdominal computed tomography. Eur J Radiol 2024; 179:111664. [PMID: 39121745 DOI: 10.1016/j.ejrad.2024.111664] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2024] [Revised: 07/04/2024] [Accepted: 08/02/2024] [Indexed: 08/12/2024]
Abstract
OBJECTIVES To investigate whether high concentration iodinated contrast media (CM), compared with low concentration CM, could reduce pain and discomfort levels in patients who had level II and III venous conditions. METHODS This prospective, single-center study enrolled patients who had level II and III venous conditions and underwent abdominal contrast-enhanced CT scan between July 2021 and February 2022. The venous condition to establish peripheral venous access for CM injection was graded using the Intravenous Access Scoring system, of which level II and III indicated poor venous condition and difficult venous access. Patients received iomeprol 400 in high concentration group and ioversol 320 in low group at an identical iodine delivery rate of 1.12 gI/s. The primary outcomes were pain and comfort levels. The secondary outcomes included adverse events and image quality. Patients rated pain intensity via Numerical Rating Scale and comfort level via Visual Analogue Scale with higher scores indicating higher levels of pain and discomfort. Quantitative and qualitative image assessment were compared between two groups. Continuous variables were compared using Student's t test or Mann-Whitney U test. Categorical variables were compared using χ2 test, χ2 test for trend or Fisher's exact test. RESULTS A total of 206 patients (mean age, 60.13 ± 12.14 years; 81 males) were included with 99 in the high concentration group and 107 in the low concentration group. The high group had significantly lower pain scores (median 1 [IQR: 0-2] vs 2 (IQR 2-4), p < 0.001) and comfort scores (1 [IQR: 0-3] vs 3 [IQR: 2-5], p < 0.001) than the low group. Incidence of CM extravasation did not significantly differ (1.0 % vs 4.5 %, p = 0.214). No hypersensitivity reaction was observed. Qualitative assessment showed higher clarity scores of intrahepatic hepatic artery and portal vein in the high group. Quantitative assessment results were comparable between two groups. CONCLUSION High concentration iodinated CM could lower pain intensity and improve comfort levels without comprising image quality of CT scan. High concentration CM is a preferable choice in patients with poor venous conditions during contrast-enhanced CT scan.
Collapse
Affiliation(s)
- Yan-Xia Sun
- Department of Radiology, Peking University Cancer Hospital and Institute, Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Beijing 100142, China
| | - Jing Shang
- Department of Radiology, Peking University Cancer Hospital and Institute, Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Beijing 100142, China
| | - Yong Cui
- Department of Radiology, Peking University Cancer Hospital and Institute, Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Beijing 100142, China
| | - Ke-Jin Zhang
- Department of Radiology, Peking University Cancer Hospital and Institute, Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Beijing 100142, China
| | - Xiao-Ting Li
- Department of Radiology, Peking University Cancer Hospital and Institute, Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Beijing 100142, China
| | - Dan-Ni Li
- Department of Radiology, Peking University Cancer Hospital and Institute, Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Beijing 100142, China
| | - Xiao-Lei Gu
- Department of Radiology, Peking University Cancer Hospital and Institute, Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Beijing 100142, China
| | - Xiao-Yu Tian
- School of Health Policy & Management, Nanjing Medical University, Nanjing 211166, China
| | - Nan Sun
- Department of Radiology, Peking University Cancer Hospital and Institute, Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Beijing 100142, China
| | - Lan Zhang
- MRI Department, The 1st Affiliated Hospital of Henan University of Chinese Medicine, Zhengzhou 450046, China
| | - Miao-Ning You
- Department of Breast Oncology, Peking University Cancer Hospital and Institute, Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Beijing 100142, China.
| | - Xiao-Yan Zhang
- Department of Radiology, Peking University Cancer Hospital and Institute, Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Beijing 100142, China.
| | - Ying-Shi Sun
- Department of Radiology, Peking University Cancer Hospital and Institute, Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Beijing 100142, China
| |
Collapse
|
2
|
Bettini A, Patrick PS, Day RM, Stuckey DJ. CT-Visible Microspheres Enable Whole-Body In Vivo Tracking of Injectable Tissue Engineering Scaffolds. Adv Healthc Mater 2024; 13:e2303588. [PMID: 38678393 PMCID: PMC11468734 DOI: 10.1002/adhm.202303588] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Revised: 02/27/2024] [Indexed: 04/30/2024]
Abstract
Targeted delivery and retention are essential requirements for implantable tissue-engineered products. Non-invasive imaging methods that can confirm location, retention, and biodistribution of transplanted cells attached to implanted tissue engineering scaffolds will be invaluable for the optimization and enhancement of regenerative therapies. To address this need, an injectable tissue engineering scaffold consisting of highly porous microspheres compatible with transplantation of cells is modified to contain the computed tomography (CT) contrast agent barium sulphate (BaSO4). The trackable microspheres show high x-ray absorption, with contrast permitting whole-body tracking. The microspheres are cellularized with GFP+ Luciferase+ mesenchymal stem cells and show in vitro biocompatibility. In vivo, cellularized BaSO4-loaded microspheres are delivered into the hindlimb of mice where they remain viable for 14 days. Co-registration of 3D-bioluminescent imaging and µCT reconstructions enable the assessment of scaffold material and cell co-localization. The trackable microspheres are also compatible with minimally-invasive delivery by ultrasound-guided transthoracic intramyocardial injections in rats. These findings suggest that BaSO4-loaded microspheres can be used as a novel tool for optimizing delivery techniques and tracking persistence and distribution of implanted scaffold materials. Additionally, the microspheres can be cellularized and have the potential to be developed into an injectable tissue-engineered combination product for cardiac regeneration.
Collapse
Affiliation(s)
- Annalisa Bettini
- Centre for Advanced Biomedical ImagingDivision of MedicineUniversity College LondonLondonWC1E 6DDUK
- Centre for Precision HealthcareDivision of MedicineUniversity College LondonLondonWC1E 6JFUK
| | - Peter Stephen Patrick
- Centre for Advanced Biomedical ImagingDivision of MedicineUniversity College LondonLondonWC1E 6DDUK
| | - Richard M. Day
- Centre for Precision HealthcareDivision of MedicineUniversity College LondonLondonWC1E 6JFUK
| | - Daniel J. Stuckey
- Centre for Advanced Biomedical ImagingDivision of MedicineUniversity College LondonLondonWC1E 6DDUK
| |
Collapse
|
3
|
Yuan D, Wang L, Lyu P, Zhang Y, Gao J, Liu J. Evaluation of image quality on low contrast media with deep learning image reconstruction algorithm in prospective ECG-triggering coronary CT angiography. THE INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING 2024; 40:1377-1388. [PMID: 38722507 DOI: 10.1007/s10554-024-03113-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Accepted: 04/08/2024] [Indexed: 06/29/2024]
Abstract
To assess the impact of low-dose contrast media (CM) injection protocol with deep learning image reconstruction (DLIR) algorithm on image quality in coronary CT angiography (CCTA). In this prospective study, patients underwent CCTA were prospectively and randomly assigned to three groups with different contrast volume protocols (at 320mgI/mL concentration and constant flow rate of 5ml/s). After pairing basic information, 210 patients were enrolled in this study: Group A, 0.7mL/kg (n = 70); Group B, 0.6mL/kg (n = 70); Group C, 0.5mL/kg (n = 70). All patients were examined via a prospective ECG-triggered scan protocol within one heartbeat. A high level DLIR (DLIR-H) algorithm was used for image reconstruction with a thickness and interval of 0.625mm. The CT values of ascending aorta (AA), descending aorta (DA), three main coronary arteries, pulmonary artery (PA), and superior vena cava (SVC) were measured and analyzed for objective assessment. Two radiologists assessed the image quality and diagnostic confidence using a 5-point Likert scale. The CM doses were 46.81 ± 6.41mL, 41.96 ± 7.51mL and 34.65 ± 5.38mL for Group A, B and C, respectively. The objective assessments on AA, DA and the three main coronary arteries and the overall subjective scoring showed no significant difference among the three groups (all p > 0.05). The subjective assessment proved that excellent CCTA images can be obtained from the three different contrast media protocols. There were no significant differences in intracoronary attenuation values between the higher HR subgroup and the lower HR subgroup among three groups. CCTA reconstructed with DLIR could be realized with adequate enhancement in coronary arteries, excellent image quality and diagnostic confidence at low contrast dose of a 0.5mL/kg. The use of lower tube voltages may further reduce the contrast dose requirement.
Collapse
Affiliation(s)
- Dian Yuan
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou, Henan Province, 450052, China
| | - Luotong Wang
- CT Imaging Research Center, GE Healthcare China, Beijing, 100176, China
| | - Peijie Lyu
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou, Henan Province, 450052, China
| | - Yonggao Zhang
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou, Henan Province, 450052, China
| | - Jianbo Gao
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou, Henan Province, 450052, China
| | - Jie Liu
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou, Henan Province, 450052, China.
| |
Collapse
|
4
|
Liu ZC, Zhao S, Ma ZP, Zhang TL, Zhao YX. Comparing feasibility of different tube voltages and different concentrations of contrast medium in coronary CT angiography of overweight patients. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2022; 30:1261-1272. [PMID: 36214032 DOI: 10.3233/xst-221263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
OBJECTIVES To compare image quality, radiation dose, and iodine intake of coronary computed tomography angiography (CCTA) acquired by wide-detector using different tube voltages and different concentrations of contrast medium (CM) for overweight patients. MATERIALS AND METHODS A total of 150 overweight patients (body mass index≥25 kg/m2) who underwent CCTA are enrolled and divided into three groups according to scan protocols namely, group A (120 kVp, 370 mgI/ml CM); group B (100 kVp, 350 mgI/ml CM); and group C (80 kVp, 320 mgI/ml CM). The CT values, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure-of-merit (FOM) of all images are calculated. Images are subjectively assessed using a 5-point scale. In addition, the CT dose index volume (CTDIvol) and dose length product (DLP) of each patient are recorded. The effective radiation dose (ED) is also calculated. Above data are then statistically analyzed. RESULTS The mean CT values, SNR, CNR, and subjective image quality of group A are significantly lower than those of groups B and C (P < 0.001), but there is no significant difference between groups B and C (P > 0.05). FOMs show a significantly increase trend from group A to C (P < 0.001). The ED values and total iodine intake in groups B and C are 30.34% and 68.53% and 10.22% and 16.85% lower than those in group A, respectively (P < 0.001). CONCLUSION The lower tube voltage and lower concentration of CM based on wide-detector allows for significant reduction in iodine load and radiation dose in CCTA for overweight patients comparing to routine scan protocols. It also enhances signal intensity of CCTA and maintains image quality.
Collapse
Affiliation(s)
- Zhi-Chao Liu
- Department of Radiology, The Affiliated Hospital of Hebei University, Baoding City, China
| | - Sai Zhao
- Department of Radiology, The Affiliated Hospital of Hebei University, Baoding City, China
| | - Ze-Peng Ma
- Department of Radiology, The Affiliated Hospital of Hebei University, Baoding City, China
| | - Tian-Le Zhang
- Department of Radiology, The Affiliated Hospital of Hebei University, Baoding City, China
| | - Yong-Xia Zhao
- Department of Radiology, The Affiliated Hospital of Hebei University, Baoding City, China
| |
Collapse
|
5
|
Sun J, Li H, Li J, Cao Y, Zhou Z, Li M, Peng Y. Performance evaluation of using shorter contrast injection and 70 kVp with deep learning image reconstruction for reduced contrast medium dose and radiation dose in coronary CT angiography for children: a pilot study. Quant Imaging Med Surg 2021; 11:4162-4171. [PMID: 34476196 DOI: 10.21037/qims-20-1159] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Accepted: 04/22/2021] [Indexed: 01/22/2023]
Abstract
Background Iterative reconstruction algorithms are often used to reduce image noise in low-dose coronary computed tomography angiography (CCTA) but encounter limitations. The newly introduced deep learning image reconstruction (DLIR) algorithm may provide new opportunities. We assessed the image quality and diagnostic performance of DLIR in low radiation dose and contrast medium dose CCTA of pediatric patients with 70 kVp and a shortened injection protocol. Methods This was a prospective study. A total of 27 consecutive arrhythmic pediatric patients were enrolled in the study group and underwent CCTA using a prospective ECG-triggered single-beat protocol: tube voltage 70 kVp, automatic tube current modulation for a noise index (NI) of 22, and contrast dose of 0.4-0.6 mL/kg. Images were reconstructed with DLIR. They were compared with 27 matched patients in the control group scanned with 80 kVp, a lower NI setting (NI =19), and a higher contrast dose (0.8-1.2 mL/kg). The images in the control group were reconstructed using the adaptive statistical iterative reconstruction (ASIR-V) algorithm. The image contrast, image quality, and diagnostic confidence were assessed by 2 experienced radiologists using a 5-point scale (1: nondiagnostic and 5: excellent). The CT value and standard deviation of the aorta and perivascular tissue were measured, and the contrast-to-noise ratio (CNR) for the aorta was calculated. The contrast medium and radiation doses were compared. Results The study and control groups had similar image contrast scores (4.75±0.57 vs. 4.78±0.42), image quality scores (3.67±0.47 vs. 3.44±0.51), and diagnostic confidence (4.74±0.44 vs. 4.74±0.45) (all P>0.05). There was an adequate enhancement in the aorta (614.74±127.73 vs. 705.89±111.20 HU) and similar CNR (20.34±4.64 vs. 20.99±4.14) in both groups. The image noise of the study group was lower in the aorta (30.61±3.88 vs. 34.77±3.49) and similar in perivascular tissue (27.66±6.24 vs. 27.55±3.33) compared with the control group. The study group reduced the total contrast medium dose by 53% to 15.07±3.68 mL and radiation dose by 36% to 0.57±0.31 mSv. Conclusions The DLIR algorithm in CCTA for children using 70 kVp tube voltage with a shortened contrast medium injection protocol maintains image quality and diagnostic confidence while significantly reducing contrast medium dose and radiation dose compared with the use of the conventional CCTA protocol.
Collapse
Affiliation(s)
- Jihang Sun
- Imaging Center, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, China
| | - Haoyan Li
- Imaging Center, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, China
| | | | - Yongli Cao
- Imaging Center, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, China
| | - Zuofu Zhou
- Department of Radiology, Fujian Provincial Maternity and Children's Hospital, Affiliated Hospital of Fujian Medical University, Fuzhou, China
| | - Michelle Li
- Department of Human Biology, Stanford University, CA, USA
| | - Yun Peng
- Imaging Center, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, China
| |
Collapse
|