Brendel JM, Jacoby J, Dehdab R, Ursprung S, Fritz V, Werner S, Herrmann J, Brendlin AS, Gassenmaier S, Schick F, Nickel D, Nikolaou K, Afat S, Almansour H. Prospective Deployment of Deep Learning Reconstruction Facilitates Highly Accelerated Upper Abdominal MRI. Acad Radiol 2024; 31:4965-4973. [PMID: 38955591 DOI: 10.1016/j.acra.2024.05.044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2024] [Revised: 05/24/2024] [Accepted: 05/26/2024] [Indexed: 07/04/2024]
Abstract
RATIONALE AND OBJECTIVES To compare a conventional T1 volumetric interpolated breath-hold examination (VIBE) with SPectral Attenuated Inversion Recovery (SPAIR) fat saturation and a deep learning (DL)-reconstructed accelerated VIBE sequence with SPAIR fat saturation achieving a 50 % reduction in breath-hold duration (hereafter, VIBE-SPAIRDL) in terms of image quality and diagnostic confidence. MATERIALS AND METHODS This prospective study enrolled consecutive patients referred for upper abdominal MRI from November 2023 to December 2023 at a single tertiary center. Patients underwent upper abdominal MRI with acquisition of non-contrast and gadobutrol-enhanced conventional VIBE-SPAIR (fourfold acceleration, acquisition time 16 s) and VIBE-SPAIRDL (sixfold acceleration, acquisition time 8 s) on a 1.5 T scanner. Image analysis was performed by four readers, evaluating homogeneity of fat suppression, perceived signal-to-noise ratio (SNR), edge sharpness, artifact level, lesion detectability and diagnostic confidence. A statistical power analysis for patient sample size estimation was performed. Image quality parameters were compared by a repeated measures analysis of variance, and interreader agreement was assessed using Fleiss' κ. RESULTS Among 450 consecutive patients, 45 patients were evaluated (mean age, 60 years ± 15 [SD]; 27 men, 18 women). VIBE-SPAIRDL acquisition demonstrated superior SNR (P < 0.001), edge sharpness (P < 0.001), and reduced artifacts (P < 0.001) with substantial to almost perfect interreader agreement for non-contrast (κ: 0.70-0.91) and gadobutrol-enhanced MRI (κ: 0.68-0.87). No evidence of a difference was found between conventional VIBE-SPAIR and VIBE-SPAIRDL regarding homogeneity of fat suppression, lesion detectability, or diagnostic confidence (all P > 0.05). CONCLUSION Deep learning reconstruction of VIBE-SPAIR facilitated a reduction of breath-hold duration by half, while reducing artifacts and improving image quality. SUMMARY Deep learning reconstruction of prospectively accelerated T1 volumetric interpolated breath-hold examination for upper abdominal MRI enabled a 50 % reduction in breath-hold time with superior image quality. KEY RESULTS 1) In a prospective analysis of 45 patients referred for upper abdominal MRI, accelerated deep learning (DL)-reconstructed VIBE images with spectral fat saturation (SPAIR) showed better overall image quality, with better perceived signal-to-noise ratio and less artifacts (all P < 0.001), despite a 50 % reduction in acquisition time compared to conventional VIBE. 2) No evidence of a difference was found between conventional VIBE-SPAIR and accelerated VIBE-SPAIRDL regarding lesion detectability or diagnostic confidence.
Collapse
Affiliation(s)
- Jan M Brendel
- Department of Radiology, Diagnostic and Interventional Radiology, Tuebingen University Hospital, University of Tuebingen, Tuebingen, Germany
| | - Johann Jacoby
- Institute of Clinical Epidemiology and Applied Biometry, Tuebingen University Hospital, University of Tuebingen, Tuebingen, Germany
| | - Reza Dehdab
- Department of Radiology, Diagnostic and Interventional Radiology, Tuebingen University Hospital, University of Tuebingen, Tuebingen, Germany
| | - Stephan Ursprung
- Department of Radiology, Diagnostic and Interventional Radiology, Tuebingen University Hospital, University of Tuebingen, Tuebingen, Germany
| | - Victor Fritz
- Department of Radiology, Section for Experimental Radiology, Tuebingen University Hospital, University of Tuebingen, Tuebingen, Germany
| | - Sebastian Werner
- Department of Radiology, Diagnostic and Interventional Radiology, Tuebingen University Hospital, University of Tuebingen, Tuebingen, Germany
| | - Judith Herrmann
- Department of Radiology, Diagnostic and Interventional Radiology, Tuebingen University Hospital, University of Tuebingen, Tuebingen, Germany
| | - Andreas S Brendlin
- Department of Radiology, Diagnostic and Interventional Radiology, Tuebingen University Hospital, University of Tuebingen, Tuebingen, Germany
| | - Sebastian Gassenmaier
- Department of Radiology, Diagnostic and Interventional Radiology, Tuebingen University Hospital, University of Tuebingen, Tuebingen, Germany
| | - Fritz Schick
- Department of Radiology, Section for Experimental Radiology, Tuebingen University Hospital, University of Tuebingen, Tuebingen, Germany
| | - Dominik Nickel
- Department of MR Application Predevelopment, Siemens Healthineers, Forchheim, Germany
| | - Konstantin Nikolaou
- Department of Radiology, Diagnostic and Interventional Radiology, Tuebingen University Hospital, University of Tuebingen, Tuebingen, Germany; Cluster of Excellence iFIT (EXC 2180) "Image-guided and Functionally Instructed Tumor Therapies", University of Tuebingen, Tuebingen, Germany
| | - Saif Afat
- Department of Radiology, Diagnostic and Interventional Radiology, Tuebingen University Hospital, University of Tuebingen, Tuebingen, Germany
| | - Haidara Almansour
- Department of Radiology, Diagnostic and Interventional Radiology, Tuebingen University Hospital, University of Tuebingen, Tuebingen, Germany.
| |
Collapse
|
2
|
Ruff C, Bombach P, Roder C, Weinbrenner E, Artzner C, Zerweck L, Paulsen F, Hauser TK, Ernemann U, Gohla G. Multidisciplinary quantitative and qualitative assessment of IDH-mutant gliomas with full diagnostic deep learning image reconstruction. Eur J Radiol Open 2024; 13:100617. [PMID: 39717474 PMCID: PMC11664152 DOI: 10.1016/j.ejro.2024.100617] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2024] [Revised: 11/19/2024] [Accepted: 11/28/2024] [Indexed: 12/25/2024] Open
Abstract
Rationale and Objectives: Diagnostic accuracy and therapeutic decision-making for IDH-mutant gliomas in tumor board reviews are based on MRI and multidisciplinary interactions. Materials and Methods This study explores the feasibility of deep learning-based reconstruction (DLR) in MRI for IDH-mutant gliomas. The research utilizes a multidisciplinary approach, engaging neuroradiologists, neurosurgeons, neuro-oncologists, and radiotherapists to evaluate qualitative aspects of DLR and conventional reconstructed (CR) sequences. Furthermore, quantitative image quality and tumor volumes according to Response Assessment in Neuro-Oncology (RANO) 2.0 standards were assessed. Results All DLR sequences consistently outperformed CR sequences (median of 4 for all) in qualitative image quality across all raters (p < 0.001 for all) and revealed higher SNR and CNR values (p < 0.001 for all). Preference for all DLR over CR was overwhelming, with ratings of 84 % from the neuroradiologist, 100 % from the neurosurgeon, 92 % from the neuro-oncologist, and 84 % from the radiation oncologist. The RANO 2.0 compliant measurements showed no significant difference between the CR and DRL sequences (p = 0.142). Conclusion This study demonstrates the clinical feasibility of DLR in MR imaging of IDH-mutant gliomas, with significant time savings of 29.6 % on average and non-inferior image quality to CR. DLR sequences received strong multidisciplinary preference, underscoring their potential for enhancing neuro-oncological decision-making and suitability for clinical implementation.
Collapse
Affiliation(s)
- Christer Ruff
- Department of Diagnostic and Interventional Neuroradiology, Eberhard Karls-University Tuebingen, Tuebingen D-72076, Germany
| | - Paula Bombach
- Department of Neurology and Interdisciplinary Neuro-Oncology, University Hospital Tuebingen, Tuebingen D-72076, Germany
- Hertie Institute for Clinical Brain Research, Eberhard Karls University Tuebingen Center of Neuro-Oncology, Tuebingen D-72076, Germany
- Center for Neuro-Oncology, Comprehensive Cancer Center Tuebingen-Stuttgart, University Hospital of Tuebingen, Eberhard Karls University of Tuebingen, Tuebingen D-72070, Germany
| | - Constantin Roder
- Center for Neuro-Oncology, Comprehensive Cancer Center Tuebingen-Stuttgart, University Hospital of Tuebingen, Eberhard Karls University of Tuebingen, Tuebingen D-72070, Germany
- Department of Neurosurgery, University of Tuebingen, Tuebingen D-72076, Germany
| | - Eliane Weinbrenner
- Department of Diagnostic and Interventional Neuroradiology, Eberhard Karls-University Tuebingen, Tuebingen D-72076, Germany
| | - Christoph Artzner
- Department of Diagnostic and Interventional Radiology, Diakonie Klinikum Stuttgart, Stuttgart D-70176, Germany
| | - Leonie Zerweck
- Department of Diagnostic and Interventional Neuroradiology, Eberhard Karls-University Tuebingen, Tuebingen D-72076, Germany
| | - Frank Paulsen
- Department of Radiation Oncology, University Hospital Tuebingen, Tuebingen D-72076, Germany
| | - Till-Karsten Hauser
- Department of Diagnostic and Interventional Neuroradiology, Eberhard Karls-University Tuebingen, Tuebingen D-72076, Germany
| | - Ulrike Ernemann
- Department of Diagnostic and Interventional Neuroradiology, Eberhard Karls-University Tuebingen, Tuebingen D-72076, Germany
| | - Georg Gohla
- Department of Diagnostic and Interventional Neuroradiology, Eberhard Karls-University Tuebingen, Tuebingen D-72076, Germany
| |
Collapse
|
3
|
Bathla G, Messina SA, Black DF, Benson JC, Kollasch P, Nickel MD, Soni N, Rucker BC, Mark IT, Diehn FE, Agarwal AK. Deep Learning-Based Reconstruction of 3D T1 SPACE Vessel Wall Imaging Provides Improved Image Quality with Reduced Scan Times: A Preliminary Study. AJNR Am J Neuroradiol 2024; 45:1655-1660. [PMID: 38889969 PMCID: PMC11543076 DOI: 10.3174/ajnr.a8382] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2024] [Accepted: 06/06/2024] [Indexed: 06/20/2024]
Abstract
BACKGROUND AND PURPOSE Intracranial vessel wall imaging is technically challenging to implement, given the simultaneous requirements of high spatial resolution, excellent blood and CSF signal suppression, and clinically acceptable gradient times. Herein, we present our preliminary findings on the evaluation of a deep learning-optimized sequence using T1-weighted imaging. MATERIALS AND METHODS Clinical and optimized deep learning-based image reconstruction T1 3D Sampling Perfection with Application optimized Contrast using different flip angle Evolution (SPACE) were evaluated, comparing noncontrast sequences in 10 healthy controls and postcontrast sequences in 5 consecutive patients. Images were reviewed on a Likert-like scale by 4 fellowship-trained neuroradiologists. Scores (range, 1-4) were separately assigned for 11 vessel segments in terms of vessel wall and lumen delineation. Additionally, images were evaluated in terms of overall background noise, image sharpness, and homogeneous CSF signal. Segment-wise scores were compared using paired samples t tests. RESULTS The scan time for the clinical and deep learning-based image reconstruction sequences were 7:26 minutes and 5:23 minutes respectively. Deep learning-based image reconstruction images showed consistently higher wall signal and lumen visualization scores, with the differences being statistically significant in most vessel segments on both pre- and postcontrast images. Deep learning-based image reconstruction had lower background noise, higher image sharpness, and uniform CSF signal. Depiction of intracranial pathologies was better or similar on the deep learning-based image reconstruction. CONCLUSIONS Our preliminary findings suggest that deep learning-based image reconstruction-optimized intracranial vessel wall imaging sequences may be helpful in achieving shorter gradient times with improved vessel wall visualization and overall image quality. These improvements may help with wider adoption of intracranial vessel wall imaging in clinical practice and should be further validated on a larger cohort.
Collapse
Affiliation(s)
- Girish Bathla
- From the Department of Radiology (G.B., S.A.M., D.F.B., J.C.B., B.C.R., I.T.M., F.E.D.), Mayo Clinic, Rochester, Minnesota
| | - Steven A Messina
- From the Department of Radiology (G.B., S.A.M., D.F.B., J.C.B., B.C.R., I.T.M., F.E.D.), Mayo Clinic, Rochester, Minnesota
| | - David F Black
- From the Department of Radiology (G.B., S.A.M., D.F.B., J.C.B., B.C.R., I.T.M., F.E.D.), Mayo Clinic, Rochester, Minnesota
| | - John C Benson
- From the Department of Radiology (G.B., S.A.M., D.F.B., J.C.B., B.C.R., I.T.M., F.E.D.), Mayo Clinic, Rochester, Minnesota
| | - Peter Kollasch
- Siemens Healthineers AG (P.K., M.D.N.), Forchheim, Germany
| | | | - Neetu Soni
- Department of Radiology (N.S., A.K.A.), Mayo Clinic, Jacksonville, Florida
| | - Brian C Rucker
- From the Department of Radiology (G.B., S.A.M., D.F.B., J.C.B., B.C.R., I.T.M., F.E.D.), Mayo Clinic, Rochester, Minnesota
| | - Ian T Mark
- From the Department of Radiology (G.B., S.A.M., D.F.B., J.C.B., B.C.R., I.T.M., F.E.D.), Mayo Clinic, Rochester, Minnesota
| | - Felix E Diehn
- From the Department of Radiology (G.B., S.A.M., D.F.B., J.C.B., B.C.R., I.T.M., F.E.D.), Mayo Clinic, Rochester, Minnesota
| | - Amit K Agarwal
- Department of Radiology (N.S., A.K.A.), Mayo Clinic, Jacksonville, Florida
| |
Collapse
|
4
|
Nishioka N, Shimizu Y, Kaneko Y, Shirai T, Suzuki A, Amemiya T, Ochi H, Bito Y, Takizawa M, Ikebe Y, Kameda H, Harada T, Fujima N, Kudo K. Accelerating FLAIR imaging via deep learning reconstruction: potential for evaluating white matter hyperintensities. Jpn J Radiol 2024:10.1007/s11604-024-01666-5. [PMID: 39316286 DOI: 10.1007/s11604-024-01666-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2024] [Accepted: 09/16/2024] [Indexed: 09/25/2024]
Abstract
PURPOSE To evaluate deep learning-reconstructed (DLR)-fluid-attenuated inversion recovery (FLAIR) images generated from undersampled data, compare them with fully sampled and rapidly acquired FLAIR images, and assess their potential for white matter hyperintensity evaluation. MATERIALS AND METHODS We examined 30 patients with white matter hyperintensities, obtaining fully sampled FLAIR images (standard FLAIR, std-FLAIR). We created accelerated FLAIR (acc-FLAIR) images using one-third of the fully sampled data and applied deep learning to generate DLR-FLAIR images. Three neuroradiologists assessed the quality (amount of noise and gray/white matter contrast) in all three image types. The reproducibility of hyperintensities was evaluated by comparing a subset of 100 hyperintensities in acc-FLAIR and DLR-FLAIR images with those in the std-FLAIR images. Quantitatively, similarities and errors of the entire image and the focused regions on white matter hyperintensities in acc-FLAIR and DLR-FLAIR images were measured against std-FLAIR images using structural similarity index measure (SSIM), regional SSIM, normalized root mean square error (NRMSE), and regional NRMSE values. RESULTS All three neuroradiologists evaluated DLR-FLAIR as having significantly less noise and higher image quality scores compared with std-FLAIR and acc-FLAIR (p < 0.001). All three neuroradiologists assigned significantly higher frontal lobe gray/white matter visibility scores for DLR-FLAIR than for acc-FLAIR (p < 0.001); two neuroradiologists attributed significantly higher scores for DLR-FLAIR than for std-FLAIR (p < 0.05). Regarding white matter hyperintensities, all three neuroradiologists significantly preferred DLR-FLAIR (p < 0.0001). DLR-FLAIR exhibited higher similarity to std-FLAIR in terms of visibility of the hyperintensities, with 97% of the hyperintensities rated as nearly identical or equivalent. Quantitatively, DLR-FLAIR demonstrated significantly higher SSIM and regional SSIM values than acc-FLAIR, with significantly lower NRMSE and regional NRMSE values (p < 0.0001). CONCLUSIONS DLR-FLAIR can reduce scan time and generate images of similar quality to std-FLAIR in patients with white matter hyperintensities. Therefore, DLR-FLAIR may serve as an effective method in traditional magnetic resonance imaging protocols.
Collapse
Affiliation(s)
- Noriko Nishioka
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Sapporo, Japan
- Department of Diagnostic Imaging, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Sapporo, Japan
| | - Yukie Shimizu
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Sapporo, Japan.
- Department of Diagnostic Imaging, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Sapporo, Japan.
| | - Yukio Kaneko
- Medical Systems Research & Development Center, FUJIFILM Corporation, Tokyo, Japan
| | - Toru Shirai
- Medical Systems Research & Development Center, FUJIFILM Corporation, Tokyo, Japan
| | - Atsuro Suzuki
- Medical Systems Research & Development Center, FUJIFILM Corporation, Tokyo, Japan
| | - Tomoki Amemiya
- Medical Systems Research & Development Center, FUJIFILM Corporation, Tokyo, Japan
| | - Hisaaki Ochi
- Medical Systems Research & Development Center, FUJIFILM Corporation, Tokyo, Japan
| | - Yoshitaka Bito
- Department of Diagnostic Imaging, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Sapporo, Japan
- FUJIFILM Healthcare Corporation, Tokyo, Japan
| | | | - Yohei Ikebe
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Sapporo, Japan
- Center for Cause of Death Investigation, Faculty of Medicine, Hokkaido University, Sapporo, Japan
| | - Hiroyuki Kameda
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Sapporo, Japan
- Faculty of Dental Medicine, Department of Radiology, Hokkaido University, Sapporo, Japan
| | - Taisuke Harada
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Sapporo, Japan
- Department of Diagnostic Imaging, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Sapporo, Japan
| | - Noriyuki Fujima
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Sapporo, Japan
- Department of Diagnostic Imaging, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Sapporo, Japan
| | - Kohsuke Kudo
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Sapporo, Japan
- Department of Diagnostic Imaging, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Sapporo, Japan
- Center for Cause of Death Investigation, Faculty of Medicine, Hokkaido University, Sapporo, Japan
- Division of Medical AI Education and Research, Hokkaido University Graduate School of Medicine, Sapporo, Japan
| |
Collapse
|
5
|
Liebrand LC, Karkalousos D, Poirion É, Emmer BJ, Roosendaal SD, Marquering HA, Majoie CBLM, Savatovsky J, Caan MWA. Deep learning for efficient reconstruction of highly accelerated 3D FLAIR MRI in neurological deficits. MAGMA (NEW YORK, N.Y.) 2024:10.1007/s10334-024-01200-8. [PMID: 39212832 DOI: 10.1007/s10334-024-01200-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2024] [Revised: 08/07/2024] [Accepted: 08/08/2024] [Indexed: 09/04/2024]
Abstract
OBJECTIVE To compare compressed sensing (CS) and the Cascades of Independently Recurrent Inference Machines (CIRIM) with respect to image quality and reconstruction times when 12-fold accelerated scans of patients with neurological deficits are reconstructed. MATERIALS AND METHODS Twelve-fold accelerated 3D T2-FLAIR images were obtained from a cohort of 62 patients with neurological deficits on 3 T MRI. Images were reconstructed offline via CS and the CIRIM. Image quality was assessed in a blinded and randomized manner by two experienced interventional neuroradiologists and one experienced pediatric neuroradiologist on imaging artifacts, perceived spatial resolution (sharpness), anatomic conspicuity, diagnostic confidence, and contrast. The methods were also compared in terms of self-referenced quality metrics, image resolution, patient groups and reconstruction time. In ten scans, the contrast ratio (CR) was determined between lesions and white matter. The effect of acceleration factor was assessed in a publicly available fully sampled dataset, since ground truth data are not available in prospectively accelerated clinical scans. Specifically, 451 FLAIR scans, including scans with white matter lesions, were adopted from the FastMRI database to evaluate structural similarity (SSIM) and the CR of lesions and white matter on ranging acceleration factors from four-fold up to 12-fold. RESULTS Interventional neuroradiologists significantly preferred the CIRIM for imaging artifacts, anatomic conspicuity, and contrast. One rater significantly preferred the CIRIM in terms of sharpness and diagnostic confidence. The pediatric neuroradiologist preferred CS for imaging artifacts and sharpness. Compared to CS, the CIRIM reconstructions significantly improved in terms of imaging artifacts and anatomic conspicuity (p < 0.01) for higher resolution scans while yielding a 28% higher SNR (p = 0.001) and a 5.8% lower CR (p = 0.04). There were no differences between patient groups. Additionally, CIRIM was five times faster than CS was. An increasing acceleration factor did not lead to changes in CR (p = 0.92), but led to lower SSIM (p = 0.002). DISCUSSION Patients with neurological deficits can undergo MRI at a range of moderate to high acceleration. DL reconstruction outperforms CS in terms of image resolution, efficient denoising with a modest reduction in contrast and reduced reconstruction times.
Collapse
Affiliation(s)
- Luka C Liebrand
- Department of Biomedical Engineering & Physics, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands
- Amsterdam Neuroscience, Brain Imaging, Amsterdam, The Netherlands
| | - Dimitrios Karkalousos
- Department of Biomedical Engineering & Physics, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands
- Amsterdam Neuroscience, Brain Imaging, Amsterdam, The Netherlands
- Department of Radiology and Nuclear Medicine, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands
| | - Émilie Poirion
- Fondation Rothschild Hospital, 29 Rue Manin, Paris, France
| | - Bart J Emmer
- Department of Radiology and Nuclear Medicine, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands
| | - Stefan D Roosendaal
- Department of Radiology and Nuclear Medicine, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands
| | - Henk A Marquering
- Department of Biomedical Engineering & Physics, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands
- Department of Radiology and Nuclear Medicine, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands
| | - Charles B L M Majoie
- Department of Radiology and Nuclear Medicine, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands
| | | | - Matthan W A Caan
- Department of Biomedical Engineering & Physics, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands.
- Amsterdam Neuroscience, Brain Imaging, Amsterdam, The Netherlands.
| |
Collapse
|
6
|
Schuhholz M, Ruff C, Bürkle E, Feiweier T, Clifford B, Kowarik M, Bender B. Ultrafast Brain MRI at 3 T for MS: Evaluation of a 51-Second Deep Learning-Enhanced T2-EPI-FLAIR Sequence. Diagnostics (Basel) 2024; 14:1841. [PMID: 39272626 PMCID: PMC11393910 DOI: 10.3390/diagnostics14171841] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2024] [Revised: 08/18/2024] [Accepted: 08/20/2024] [Indexed: 09/15/2024] Open
Abstract
In neuroimaging, there is no equivalent alternative to magnetic resonance imaging (MRI). However, image acquisitions are generally time-consuming, which may limit utilization in some cases, e.g., in patients who cannot remain motionless for long or suffer from claustrophobia, or in the event of extensive waiting times. For multiple sclerosis (MS) patients, MRI plays a major role in drug therapy decision-making. The purpose of this study was to evaluate whether an ultrafast, T2-weighted (T2w), deep learning-enhanced (DL), echo-planar-imaging-based (EPI) fluid-attenuated inversion recovery (FLAIR) sequence (FLAIRUF) that has targeted neurological emergencies so far might even be an option to detect MS lesions of the brain compared to conventional FLAIR sequences. Therefore, 17 MS patients were enrolled prospectively in this exploratory study. Standard MRI protocols and ultrafast acquisitions were conducted at 3 tesla (T), including three-dimensional (3D)-FLAIR, turbo/fast spin-echo (TSE)-FLAIR, and FLAIRUF. Inflammatory lesions were grouped by size and location. Lesion conspicuity and image quality were rated on an ordinal five-point Likert scale, and lesion detection rates were calculated. Statistical analyses were performed to compare results. Altogether, 568 different lesions were found. Data indicated no significant differences in lesion detection (sensitivity and positive predictive value [PPV]) between FLAIRUF and axially reconstructed 3D-FLAIR (lesion size ≥3 mm × ≥2 mm) and no differences in sensitivity between FLAIRUF and TSE-FLAIR (lesion size ≥3 mm total). Lesion conspicuity in FLAIRUF was similar in all brain regions except for superior conspicuity in the occipital lobe and inferior conspicuity in the central brain regions. Further findings include location-dependent limitations of signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) as well as artifacts such as spatial distortions in FLAIRUF. In conclusion, FLAIRUF could potentially be an expedient alternative to conventional methods for brain imaging in MS patients since the acquisition can be performed in a fraction of time while maintaining good image quality.
Collapse
Affiliation(s)
- Martin Schuhholz
- Department of Diagnostic and Interventional Neuroradiology, Eberhard Karls University, University Hospital, 72076 Tübingen, Germany
| | - Christer Ruff
- Department of Diagnostic and Interventional Neuroradiology, Eberhard Karls University, University Hospital, 72076 Tübingen, Germany
| | - Eva Bürkle
- Department of Diagnostic and Interventional Neuroradiology, Eberhard Karls University, University Hospital, 72076 Tübingen, Germany
| | | | | | - Markus Kowarik
- Department of Neurology and Stroke, Neurological Clinic, Eberhard Karls University, University Hospital, 72076 Tübingen, Germany
| | - Benjamin Bender
- Department of Diagnostic and Interventional Neuroradiology, Eberhard Karls University, University Hospital, 72076 Tübingen, Germany
| |
Collapse
|
7
|
Uher D, Drenthen GS, Poser BA, Hofman PAM, Wagner LG, van Lanen RHGJ, Hoeberigs CM, Colon AJ, Schijns OEMG, Jansen JFA, Backes WH. DeepFLAIR: A neural network approach to mitigate signal and contrast loss in temporal lobes at 7 Tesla FLAIR images. Magn Reson Imaging 2024; 110:57-68. [PMID: 38621552 DOI: 10.1016/j.mri.2024.04.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Revised: 04/04/2024] [Accepted: 04/10/2024] [Indexed: 04/17/2024]
Abstract
BACKGROUND AND PURPOSE Higher magnetic field strength introduces stronger magnetic field inhomogeneities in the brain, especially within temporal lobes, leading to image artifacts. Particularly, T2-weighted fluid-attenuated inversion recovery (FLAIR) images can be affected by these artifacts. Here, we aimed to improve the FLAIR image quality in temporal lobe regions through image processing of multiple contrast images via machine learning using a neural network. METHODS Thirteen drug-resistant MR-negative epilepsy patients (age 29.2 ± 9.4y, 5 females) were scanned on a 7 T MRI scanner. Magnetization-prepared (MP2RAGE) and saturation-prepared with 2 rapid gradient echoes, multi-echo gradient echo with four echo times, and the FLAIR sequence were acquired. A voxel-wise neural network was trained on extratemporal-lobe voxels from the acquired structural scans to generate a new FLAIR-like image (i.e., deepFLAIR) with reduced temporal lobe inhomogeneities. The deepFLAIR was evaluated in temporal lobes through signal-to-noise (SNR), contrast-to-noise (CNR) ratio, the sharpness of the gray-white matter boundary and joint-histogram analysis. Saliency mapping demonstrated the importance of each input image per voxel. RESULTS SNR and CNR in both gray and white matter were significantly increased (p < 0.05) in the deepFLAIR's temporal ROIs, compared to the FLAIR. The gray-white matter boundary sharpness was either preserved or improved in 10/13 right-sided temporal regions and was found significantly increased in the ROIs. Multiple image contrasts were influential for the deepFLAIR reconstruction with the MP2RAGE second inversion image being the most important. CONCLUSIONS The deepFLAIR network showed promise to restore the FLAIR signal and reduce contrast attenuation in temporal lobe areas. This may yield a valuable tool, especially when artifact-free FLAIR images are not available.
Collapse
Affiliation(s)
- Daniel Uher
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre, Maastricht, the Netherlands; Mental Health and Neuroscience Institute (MHeNs), Maastricht University, Maastricht, the Netherlands; Department of Neurosurgery, Maastricht University Medical Center, Maastricht, the Netherlands
| | - Gerhard S Drenthen
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre, Maastricht, the Netherlands; Mental Health and Neuroscience Institute (MHeNs), Maastricht University, Maastricht, the Netherlands
| | - Benedikt A Poser
- Faculty of Psychology and Neuroscience (FPN), Maastricht University, the Netherlands
| | - Paul A M Hofman
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre, Maastricht, the Netherlands; Academic Center for Epileptology, Kempenhaeghe and Maastricht University Medical Centre, Heeze/Maastricht, the Netherlands
| | - Louis G Wagner
- Academic Center for Epileptology, Kempenhaeghe and Maastricht University Medical Centre, Heeze/Maastricht, the Netherlands
| | - Rick H G J van Lanen
- Mental Health and Neuroscience Institute (MHeNs), Maastricht University, Maastricht, the Netherlands; Department of Neurosurgery, Maastricht University Medical Center, Maastricht, the Netherlands
| | - Christianne M Hoeberigs
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre, Maastricht, the Netherlands; Academic Center for Epileptology, Kempenhaeghe and Maastricht University Medical Centre, Heeze/Maastricht, the Netherlands
| | - Albert J Colon
- Academic Center for Epileptology, Kempenhaeghe and Maastricht University Medical Centre, Heeze/Maastricht, the Netherlands; Department of Epileptology, CHU-Martinique, Fort-de-France, France
| | - Olaf E M G Schijns
- Mental Health and Neuroscience Institute (MHeNs), Maastricht University, Maastricht, the Netherlands; Department of Neurosurgery, Maastricht University Medical Center, Maastricht, the Netherlands; Academic Center for Epileptology, Kempenhaeghe and Maastricht University Medical Centre, Heeze/Maastricht, the Netherlands
| | - Jacobus F A Jansen
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre, Maastricht, the Netherlands; Mental Health and Neuroscience Institute (MHeNs), Maastricht University, Maastricht, the Netherlands; Academic Center for Epileptology, Kempenhaeghe and Maastricht University Medical Centre, Heeze/Maastricht, the Netherlands; Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands
| | - Walter H Backes
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre, Maastricht, the Netherlands; Mental Health and Neuroscience Institute (MHeNs), Maastricht University, Maastricht, the Netherlands; Cardiovascular Diseases Institute (CARIM), Maastricht University, Maastricht, the Netherlands.
| |
Collapse
|
8
|
Gohla G, Hauser TK, Bombach P, Feucht D, Estler A, Bornemann A, Zerweck L, Weinbrenner E, Ernemann U, Ruff C. Speeding Up and Improving Image Quality in Glioblastoma MRI Protocol by Deep Learning Image Reconstruction. Cancers (Basel) 2024; 16:1827. [PMID: 38791906 PMCID: PMC11119715 DOI: 10.3390/cancers16101827] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2024] [Revised: 04/29/2024] [Accepted: 05/08/2024] [Indexed: 05/26/2024] Open
Abstract
A fully diagnostic MRI glioma protocol is key to monitoring therapy assessment but is time-consuming and especially challenging in critically ill and uncooperative patients. Artificial intelligence demonstrated promise in reducing scan time and improving image quality simultaneously. The purpose of this study was to investigate the diagnostic performance, the impact on acquisition acceleration, and the image quality of a deep learning optimized glioma protocol of the brain. Thirty-three patients with histologically confirmed glioblastoma underwent standardized brain tumor imaging according to the glioma consensus recommendations on a 3-Tesla MRI scanner. Conventional and deep learning-reconstructed (DLR) fluid-attenuated inversion recovery, and T2- and T1-weighted contrast-enhanced Turbo spin echo images with an improved in-plane resolution, i.e., super-resolution, were acquired. Two experienced neuroradiologists independently evaluated the image datasets for subjective image quality, diagnostic confidence, tumor conspicuity, noise levels, artifacts, and sharpness. In addition, the tumor volume was measured in the image datasets according to Response Assessment in Neuro-Oncology (RANO) 2.0, as well as compared between both imaging techniques, and various clinical-pathological parameters were determined. The average time saving of DLR sequences was 30% per MRI sequence. Simultaneously, DLR sequences showed superior overall image quality (all p < 0.001), improved tumor conspicuity and image sharpness (all p < 0.001, respectively), and less image noise (all p < 0.001), while maintaining diagnostic confidence (all p > 0.05), compared to conventional images. Regarding RANO 2.0, the volume of non-enhancing non-target lesions (p = 0.963), enhancing target lesions (p = 0.993), and enhancing non-target lesions (p = 0.951) did not differ between reconstruction types. The feasibility of the deep learning-optimized glioma protocol was demonstrated with a 30% reduction in acquisition time on average and an increased in-plane resolution. The evaluated DLR sequences improved subjective image quality and maintained diagnostic accuracy in tumor detection and tumor classification according to RANO 2.0.
Collapse
Affiliation(s)
- Georg Gohla
- Department of Diagnostic and Interventional Neuroradiology, Eberhard Karls-University Tübingen, 72076 Tübingen, Germany; (T.-K.H.); (A.E.); (L.Z.); (E.W.); (U.E.); (C.R.)
| | - Till-Karsten Hauser
- Department of Diagnostic and Interventional Neuroradiology, Eberhard Karls-University Tübingen, 72076 Tübingen, Germany; (T.-K.H.); (A.E.); (L.Z.); (E.W.); (U.E.); (C.R.)
| | - Paula Bombach
- Department of Neurology and Interdisciplinary Neuro-Oncology, University Hospital Tübingen, Hoppe-Seyler-Str. 3, 72076 Tübingen, Germany;
- Hertie Institute for Clinical Brain Research, Eberhard Karls University Tübingen Center of Neuro-Oncology, Ottfried-Müller-Straße 27, 72076 Tübingen, Germany
- Center for Neuro-Oncology, Comprehensive Cancer Center Tübingen-Stuttgart, University Hospital of Tuebingen, Eberhard Karls University of Tübingen, Herrenberger Straße 23, 72070 Tübingen, Germany
| | - Daniel Feucht
- Department of Neurosurgery, University Hospital Tübingen, Hoppe-Seyler-Str. 3, 72076 Tübingen, Germany;
| | - Arne Estler
- Department of Diagnostic and Interventional Neuroradiology, Eberhard Karls-University Tübingen, 72076 Tübingen, Germany; (T.-K.H.); (A.E.); (L.Z.); (E.W.); (U.E.); (C.R.)
| | - Antje Bornemann
- Department of Neuropathology, Institute of Pathology and Neuropathology, University Hospital Tübingen, Calwerstraße 3, 72076 Tübingen, Germany;
| | - Leonie Zerweck
- Department of Diagnostic and Interventional Neuroradiology, Eberhard Karls-University Tübingen, 72076 Tübingen, Germany; (T.-K.H.); (A.E.); (L.Z.); (E.W.); (U.E.); (C.R.)
| | - Eliane Weinbrenner
- Department of Diagnostic and Interventional Neuroradiology, Eberhard Karls-University Tübingen, 72076 Tübingen, Germany; (T.-K.H.); (A.E.); (L.Z.); (E.W.); (U.E.); (C.R.)
| | - Ulrike Ernemann
- Department of Diagnostic and Interventional Neuroradiology, Eberhard Karls-University Tübingen, 72076 Tübingen, Germany; (T.-K.H.); (A.E.); (L.Z.); (E.W.); (U.E.); (C.R.)
| | - Christer Ruff
- Department of Diagnostic and Interventional Neuroradiology, Eberhard Karls-University Tübingen, 72076 Tübingen, Germany; (T.-K.H.); (A.E.); (L.Z.); (E.W.); (U.E.); (C.R.)
| |
Collapse
|
9
|
Estler A, Hauser TK, Brunnée M, Zerweck L, Richter V, Knoppik J, Örgel A, Bürkle E, Adib SD, Hengel H, Nikolaou K, Ernemann U, Gohla G. Deep learning-accelerated image reconstruction in back pain-MRI imaging: reduction of acquisition time and improvement of image quality. LA RADIOLOGIA MEDICA 2024; 129:478-487. [PMID: 38349416 PMCID: PMC10943137 DOI: 10.1007/s11547-024-01787-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Accepted: 01/15/2024] [Indexed: 03/16/2024]
Abstract
INTRODUCTION Low back pain is a global health issue causing disability and missed work days. Commonly used MRI scans including T1-weighted and T2-weighted images provide detailed information of the spine and surrounding tissues. Artificial intelligence showed promise in improving image quality and simultaneously reducing scan time. This study evaluates the performance of deep learning (DL)-based T2 turbo spin-echo (TSE, T2DLR) and T1 TSE (T1DLR) in lumbar spine imaging regarding acquisition time, image quality, artifact resistance, and diagnostic confidence. MATERIAL AND METHODS This retrospective monocentric study included 60 patients with lower back pain who underwent lumbar spinal MRI between February and April 2023. MRI parameters and DL reconstruction (DLR) techniques were utilized to acquire images. Two neuroradiologists independently evaluated image datasets based on various parameters using a 4-point Likert scale. RESULTS Accelerated imaging showed significantly less image noise and artifacts, as well as better image sharpness, compared to standard imaging. Overall image quality and diagnostic confidence were higher in accelerated imaging. Relevant disk herniations and spinal fractures were detected in both DLR and conventional images. Both readers favored accelerated imaging in the majority of examinations. The lumbar spine examination time was cut by 61% in accelerated imaging compared to standard imaging. CONCLUSION In conclusion, the utilization of deep learning-based image reconstruction techniques in lumbar spinal imaging resulted in significant time savings of up to 61% compared to standard imaging, while also improving image quality and diagnostic confidence. These findings highlight the potential of these techniques to enhance efficiency and accuracy in clinical practice for patients with lower back pain.
Collapse
Affiliation(s)
- Arne Estler
- Diagnostic and Interventional Neuroradiology, Department of Radiology, University Hospital Tuebingen, Hoppe-Seyler-Str. 3, 72076, Tübingen, Baden-Württemberg, Germany
| | - Till-Karsten Hauser
- Diagnostic and Interventional Neuroradiology, Department of Radiology, University Hospital Tuebingen, Hoppe-Seyler-Str. 3, 72076, Tübingen, Baden-Württemberg, Germany
| | - Merle Brunnée
- Department of Neuroradiology, Neurological University Clinic, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Leonie Zerweck
- Diagnostic and Interventional Neuroradiology, Department of Radiology, University Hospital Tuebingen, Hoppe-Seyler-Str. 3, 72076, Tübingen, Baden-Württemberg, Germany.
| | - Vivien Richter
- Diagnostic and Interventional Neuroradiology, Department of Radiology, University Hospital Tuebingen, Hoppe-Seyler-Str. 3, 72076, Tübingen, Baden-Württemberg, Germany
| | - Jessica Knoppik
- Diagnostic and Interventional Neuroradiology, Department of Radiology, University Hospital Tuebingen, Hoppe-Seyler-Str. 3, 72076, Tübingen, Baden-Württemberg, Germany
| | - Anja Örgel
- Diagnostic and Interventional Neuroradiology, Department of Radiology, University Hospital Tuebingen, Hoppe-Seyler-Str. 3, 72076, Tübingen, Baden-Württemberg, Germany
| | - Eva Bürkle
- Diagnostic and Interventional Neuroradiology, Department of Radiology, University Hospital Tuebingen, Hoppe-Seyler-Str. 3, 72076, Tübingen, Baden-Württemberg, Germany
| | - Sasan Darius Adib
- Department of Neurosurgery, University of Tübingen, 72076, Tübingen, Germany
| | - Holger Hengel
- Department of Neurology and Hertie-Institute for Clinical Brain Research, University of Tübingen, 72076, Tübingen, Germany
| | - Konstantin Nikolaou
- Department of Diagnostic and Interventional Radiology, University of Tuebingen, Hoppe-Seyler-Str. 3, 72076, Tuebingen, Germany
| | - Ulrike Ernemann
- Diagnostic and Interventional Neuroradiology, Department of Radiology, University Hospital Tuebingen, Hoppe-Seyler-Str. 3, 72076, Tübingen, Baden-Württemberg, Germany
| | - Georg Gohla
- Diagnostic and Interventional Neuroradiology, Department of Radiology, University Hospital Tuebingen, Hoppe-Seyler-Str. 3, 72076, Tübingen, Baden-Württemberg, Germany
| |
Collapse
|
10
|
Estler A, Zerweck L, Brunnée M, Estler B, Richter V, Örgel A, Bürkle E, Becker H, Hurth H, Stahl S, Konrad EM, Kelbsch C, Ernemann U, Hauser TK, Gohla G. Deep learning-accelerated image reconstruction in MRI of the orbit to shorten acquisition time and enhance image quality. J Neuroimaging 2024; 34:232-240. [PMID: 38195858 DOI: 10.1111/jon.13187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Revised: 12/02/2023] [Accepted: 12/22/2023] [Indexed: 01/11/2024] Open
Abstract
BACKGROUND AND PURPOSE This study explores the use of deep learning (DL) techniques in MRI of the orbit to enhance imaging. Standard protocols, although detailed, have lengthy acquisition times. We investigate DL-based methods for T2-weighted and T1-weighted, fat-saturated, contrast-enhanced turbo spin echo (TSE) sequences, aiming to improve image quality, reduce acquisition time, minimize artifacts, and enhance diagnostic confidence in orbital imaging. METHODS In a 3-Tesla MRI study of 50 patients evaluating orbital diseases from March to July 2023, conventional (TSES ) and DL TSE sequences (TSEDL ) were used. Two neuroradiologists independently assessed the image datasets for image quality, diagnostic confidence, noise levels, artifacts, and image sharpness using a randomized and blinded 4-point Likert scale. RESULTS TSEDL significantly reduced image noise and artifacts, enhanced image sharpness, and decreased scan time, outperforming TSES (p < .05). TSEDL showed superior overall image quality and diagnostic confidence, with relevant findings effectively detected in both DL-based and conventional images. In 94% of cases, readers preferred accelerated imaging. CONCLUSION The study proved that using DL for MRI image reconstruction in orbital scans significantly cut acquisition time by 69%. This approach also enhanced image quality, reduced image noise, sharpened images, and boosted diagnostic confidence.
Collapse
Affiliation(s)
- Arne Estler
- Diagnostic and Interventional Neuroradiology, Department of Radiology, University Hospital Tuebingen, Tübingen, Germany
| | - Leonie Zerweck
- Diagnostic and Interventional Neuroradiology, Department of Radiology, University Hospital Tuebingen, Tübingen, Germany
| | - Merle Brunnée
- Department of Neuroradiology, Neurological University Clinic, Heidelberg University Hospital, Heidelberg, Germany
| | - Bent Estler
- Department of Cardiology, Angiology, and Pneumology, Heidelberg University Hospital, Heidelberg, Germany
| | - Vivien Richter
- Diagnostic and Interventional Neuroradiology, Department of Radiology, University Hospital Tuebingen, Tübingen, Germany
| | - Anja Örgel
- Diagnostic and Interventional Neuroradiology, Department of Radiology, University Hospital Tuebingen, Tübingen, Germany
| | - Eva Bürkle
- Diagnostic and Interventional Neuroradiology, Department of Radiology, University Hospital Tuebingen, Tübingen, Germany
| | - Hannes Becker
- Department of Neurosurgery, University of Tübingen, Tübingen, Germany
| | - Helene Hurth
- Department of Neurosurgery, University of Tübingen, Tübingen, Germany
| | | | - Eva-Maria Konrad
- Center for Ophthalmology, University Eye Hospital, University of Tübingen, Tübingen, Germany
| | - Carina Kelbsch
- Center for Ophthalmology, University Eye Hospital, University of Tübingen, Tübingen, Germany
| | - Ulrike Ernemann
- Diagnostic and Interventional Neuroradiology, Department of Radiology, University Hospital Tuebingen, Tübingen, Germany
| | - Till-Karsten Hauser
- Diagnostic and Interventional Neuroradiology, Department of Radiology, University Hospital Tuebingen, Tübingen, Germany
| | - Georg Gohla
- Diagnostic and Interventional Neuroradiology, Department of Radiology, University Hospital Tuebingen, Tübingen, Germany
| |
Collapse
|
11
|
Herrmann J, Benkert T, Brendlin A, Gassenmaier S, Hölldobler T, Maennlin S, Almansour H, Lingg A, Weiland E, Afat S. Shortening Acquisition Time and Improving Image Quality for Pelvic MRI Using Deep Learning Reconstruction for Diffusion-Weighted Imaging at 1.5 T. Acad Radiol 2024; 31:921-928. [PMID: 37500416 DOI: 10.1016/j.acra.2023.06.035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 06/28/2023] [Accepted: 06/30/2023] [Indexed: 07/29/2023]
Abstract
RATIONALE AND OBJECTIVES To determine the impact on acquisition time reduction and image quality of a deep learning (DL) reconstruction for accelerated diffusion-weighted imaging (DWI) of the pelvis at 1.5 T compared to standard DWI. MATERIALS AND METHODS A total of 55 patients (mean age, 61 ± 13 years; range, 27-89; 20 men, 35 women) were consecutively included in this retrospective, monocentric study between February and November 2022. Inclusion criteria were (1) standard DWI (DWIS) in clinically indicated magnetic resonance imaging (MRI) at 1.5 T and (2) DL-reconstructed DWI (DWIDL). All patients were examined using the institution's standard MRI protocol according to their diagnosis including DWI with two different b-values (0 and 800 s/mm2) and calculation of apparent diffusion coefficient (ADC) maps. Image quality was qualitatively assessed by four radiologists using a visual 5-point Likert scale (5 = best) for the following criteria: overall image quality, noise level, extent of artifacts, sharpness, and diagnostic confidence. The qualitative scores for DWIS and DWIDL were compared with the Wilcoxon signed-rank test. RESULTS The overall image quality was evaluated to be significantly superior in DWIDL compared to DWIS for b = 0 s/mm2, b = 800 s/mm2, and ADC maps by all readers (P < .05). The extent of noise was evaluated to be significantly less in DWIDL compared to DWIS for b = 0 s/mm2, b = 800 s/mm2, and ADC maps by all readers (P < .001). No significant differences were found regarding artifacts, lesion detectability, sharpness of organs, and diagnostic confidence (P > .05). Acquisition time for DWIS was 2:06 minutes, and simulated acquisition time for DWIDL was 1:12 minutes. CONCLUSION DL image reconstruction improves image quality, and simulation results suggest that a reduction in acquisition time for diffusion-weighted MRI of the pelvis at 1.5 T is possible.
Collapse
Affiliation(s)
- Judith Herrmann
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany
| | - Thomas Benkert
- MR Application Predevelopment, Siemens Healthcare GmbH, Erlangen, Germany
| | - Andreas Brendlin
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany
| | - Sebastian Gassenmaier
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany
| | - Thomas Hölldobler
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany
| | - Simon Maennlin
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany
| | - Haidara Almansour
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany
| | - Andreas Lingg
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany
| | - Elisabeth Weiland
- MR Application Predevelopment, Siemens Healthcare GmbH, Erlangen, Germany
| | - Saif Afat
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany.
| |
Collapse
|
12
|
Sanvito F, Kaufmann TJ, Cloughesy TF, Wen PY, Ellingson BM. Standardized brain tumor imaging protocols for clinical trials: current recommendations and tips for integration. FRONTIERS IN RADIOLOGY 2023; 3:1267615. [PMID: 38152383 PMCID: PMC10751345 DOI: 10.3389/fradi.2023.1267615] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Accepted: 11/24/2023] [Indexed: 12/29/2023]
Abstract
Standardized MRI acquisition protocols are crucial for reducing the measurement and interpretation variability associated with response assessment in brain tumor clinical trials. The main challenge is that standardized protocols should ensure high image quality while maximizing the number of institutions meeting the acquisition requirements. In recent years, extensive effort has been made by consensus groups to propose different "ideal" and "minimum requirements" brain tumor imaging protocols (BTIPs) for gliomas, brain metastases (BM), and primary central nervous system lymphomas (PCSNL). In clinical practice, BTIPs for clinical trials can be easily integrated with additional MRI sequences that may be desired for clinical patient management at individual sites. In this review, we summarize the general concepts behind the choice and timing of sequences included in the current recommended BTIPs, we provide a comparative overview, and discuss tips and caveats to integrate additional clinical or research sequences while preserving the recommended BTIPs. Finally, we also reflect on potential future directions for brain tumor imaging in clinical trials.
Collapse
Affiliation(s)
- Francesco Sanvito
- UCLA Brain Tumor Imaging Laboratory (BTIL), Center for Computer Vision and Imaging Biomarkers, University of California, Los Angeles, Los Angeles, CA, United States
- Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, CA, United States
| | | | - Timothy F. Cloughesy
- UCLA Neuro-Oncology Program, University of California, Los Angeles, Los Angeles, CA, United States
- Department of Neurology, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, CA, United States
| | - Patrick Y. Wen
- Center for Neuro-Oncology, Dana-Farber/Brigham and Women’s Cancer Center, Harvard Medical School, Boston, MA, United States
| | - Benjamin M. Ellingson
- UCLA Brain Tumor Imaging Laboratory (BTIL), Center for Computer Vision and Imaging Biomarkers, University of California, Los Angeles, Los Angeles, CA, United States
- Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, CA, United States
- Department of Bioengineering, Henry Samueli School of Engineering and Applied Science, University of California, Los Angeles, Los Angeles, CA, United States
- Department of Neurosurgery, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, CA, United States
- Department of Psychiatry and Biobehavioral Sciences, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, CA, United States
| |
Collapse
|