1
|
Petřivý Z, Horný L, Tichý P. Traction-separation law parameters for the description of age-related changes in the delamination strength of the human descending thoracic aorta. Biomech Model Mechanobiol 2024:10.1007/s10237-024-01871-1. [PMID: 38985231 DOI: 10.1007/s10237-024-01871-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2024] [Accepted: 06/25/2024] [Indexed: 07/11/2024]
Abstract
Aortic dissection is a life-threatening disease that consists in the development of a tear in the wall of the aorta. The initial tear propagates as a discontinuity leading to separation within the aortic wall, which can result in the creation of a so-called false lumen. A fatal threat occurs if the rupture extends through the whole thickness of the aortic wall, as blood may then leak. It is generally accepted that the dissection, which can sometime extend along the entire length of the aorta, propagates via a delamination mechanism. The aim of the present paper is to provide experimentally validated parameters of a mathematical model for the description of the wall's cohesion. A model of the peeling experiment was built in Abaqus. The delamination interface was described by a piecewise linear traction-separation law. The bulk behavior of the aorta was assumed to be nonlinearly elastic, anisotropic, and incompressible. Our simulations resulted in estimates of the material parameters for the traction-separation law of the human descending thoracic aorta, which were obtained by minimizing the differences between the FEM predictions and the delamination force given by the regression of the peeling experiments. The results show that the stress at damage initiation, Tc, should be understood as an age-dependent quantity, and under the assumptions of our model this dependence can be expressed by linear regression as Tc = - 13.03·10-4·Age + 0.2485 if the crack front advances in the axial direction, and Tc = - 7.58·10-4·Age + 0.1897 if the crack front advances in the direction of the aortic circumference (Tc [MPa], Age [years]). Other model parameters were the stiffness K and the separation at failure, δf-δc (K = 0.5 MPa/mm, δf-δc = 0.1 mm). The material parameters provided by our study can be used in numerical simulations of the biomechanics of dissection propagation through the aorta especially when age-associated phenomena are studied.
Collapse
Affiliation(s)
- Zdeněk Petřivý
- Faculty of Mechanical Engineering, Czech Technical University in Prague, Technická 4, 160 00, Prague, Czech Republic
| | - Lukáš Horný
- Faculty of Mechanical Engineering, Czech Technical University in Prague, Technická 4, 160 00, Prague, Czech Republic.
| | - Petr Tichý
- Faculty of Mechanical Engineering, Czech Technical University in Prague, Technická 4, 160 00, Prague, Czech Republic
| |
Collapse
|
2
|
Han H, Guo B, Gao P, Yang F, Sun C, Hill NA, Liu H. Finite-element simulation of in-plane tear propagation in the dissected aorta: Implications for the propagation mechanism. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2023; 39:e3743. [PMID: 37344920 PMCID: PMC10909461 DOI: 10.1002/cnm.3743] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Revised: 04/25/2023] [Accepted: 06/01/2023] [Indexed: 06/23/2023]
Abstract
Computer modeling and numerical simulation are essential for understanding the progression of aortic dissection. However, tear propagation has not been properly modeled and simulated. The in-plane dissection propagation between concentrically distributed elastic lamellae is modeled using the cohesive zone method with a bilinear traction-separation law. The parameters of cohesive elements are calibrated for the three modes of interfacial damage in the media, enabling quantitative predictions of in-plane tear propagation. An idealized cylindrical tube-shaped bilayer thick-wall model of the aorta is employed to elucidate the influence of geometrical parameters, loading conditions and residual stress on the tear propagation. While the model is capable of replicating that deeper, larger tears are associated with lower critical pressure, new findings include: (i) Larger axial stretch leads to lower critical pressure; (ii) Increased magnitude of residual stress is associated with higher critical pressure; (iii) Pressure difference between true and false lumen alters the critical pressure; (iv) The interfacial damage is mostly opening mode in the axial direction, but shear-dominated in the circumferential direction; (v) Damage due to the opening mode is associated with smaller fracture energy, which makes it easier to propagate than the shear and the mixed modes. (vi) The deformed shape of the tear, which is related to its geometrical features and loading conditions, modulates the critical pressure via two pathways: (a) deformed shapes are associated with specific modes of damage, which influences the critical pressure, and (b) deformed shapes modulate the critical pressure directly via geometrical constraints.
Collapse
Affiliation(s)
- Han Han
- Department of MechanicsTianjin UniversityTianjinChina
| | - Baolei Guo
- Department of Vascular SurgeryZhongshan Hospital, Fudan UniversityShanghaiChina
| | - Peng Gao
- Department of MechanicsTianjin UniversityTianjinChina
| | - Fan Yang
- Department of MechanicsTianjin UniversityTianjinChina
| | - Cuiru Sun
- Department of MechanicsTianjin UniversityTianjinChina
| | - Nicholas A. Hill
- School of Mathematics and StatisticsUniversity of GlasgowGlasgowUK
| | - Haofei Liu
- Department of MechanicsTianjin UniversityTianjinChina
| |
Collapse
|
3
|
Wang X, Carpenter HJ, Ghayesh MH, Kotousov A, Zander AC, Amabili M, Psaltis PJ. A review on the biomechanical behaviour of the aorta. J Mech Behav Biomed Mater 2023; 144:105922. [PMID: 37320894 DOI: 10.1016/j.jmbbm.2023.105922] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 05/14/2023] [Accepted: 05/20/2023] [Indexed: 06/17/2023]
Abstract
Large aortic aneurysm and acute and chronic aortic dissection are pathologies of the aorta requiring surgery. Recent advances in medical intervention have improved patient outcomes; however, a clear understanding of the mechanisms leading to aortic failure and, hence, a better understanding of failure risk, is still missing. Biomechanical analysis of the aorta could provide insights into the development and progression of aortic abnormalities, giving clinicians a powerful tool in risk stratification. The complexity of the aortic system presents significant challenges for a biomechanical study and requires various approaches to analyse the aorta. To address this, here we present a holistic review of the biomechanical studies of the aorta by categorising articles into four broad approaches, namely theoretical, in vivo, experimental and combined investigations. Experimental studies that focus on identifying mechanical properties of the aortic tissue are also included. By reviewing the literature and discussing drawbacks, limitations and future challenges in each area, we hope to present a more complete picture of the state-of-the-art of aortic biomechanics to stimulate research on critical topics. Combining experimental modalities and computational approaches could lead to more comprehensive results in risk prediction for the aortic system.
Collapse
Affiliation(s)
- Xiaochen Wang
- School of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide, South Australia 5005, Australia.
| | - Harry J Carpenter
- School of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide, South Australia 5005, Australia
| | - Mergen H Ghayesh
- School of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide, South Australia 5005, Australia.
| | - Andrei Kotousov
- School of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide, South Australia 5005, Australia
| | - Anthony C Zander
- School of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide, South Australia 5005, Australia
| | - Marco Amabili
- Department of Mechanical Engineering, McGill University, Montreal H3A 0C3, Canada
| | - Peter J Psaltis
- Adelaide Medical School, The University of Adelaide, Adelaide, South Australia 5005, Australia; Department of Cardiology, Central Adelaide Local Health Network, Adelaide, South Australia 5000, Australia; Vascular Research Centre, Heart Health Theme, South Australian Health & Medical Research Institute (SAHMRI), Adelaide, South Australia 5000, Australia
| |
Collapse
|
4
|
Alloisio M, Chatziefraimidou M, Roy J, Christian Gasser T. Fracture of the porcine aorta. Part 1: symconCT fracture testing and DIC. Acta Biomater 2023:S1742-7061(23)00347-1. [PMID: 37355178 DOI: 10.1016/j.actbio.2023.06.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Revised: 06/16/2023] [Accepted: 06/16/2023] [Indexed: 06/26/2023]
Abstract
Tissue failure and damage are inherent parts of vascular diseases and tightly linked to clinical events. Additionally, experimental set-ups designed to study classical engineering materials are suboptimal in the exploration of vessel wall fracture properties. The classical Compact Tension (CT) test was augmented to enable stable fracture propagation, resulting in the symmetry-constraint Compact Tension (symconCT) test, a suitable set-up for fracture testing of vascular tissue. The test was combined with Digital Image Correlation (DIC) to study tissue fracture in 45 porcine aorta specimens. Test specimens were loaded in axial and circumferential directions in a physiological solution at 37∘ C. Loading the aortic vessel wall in the axial direction resulted in mode I tissue failure and a fracture path aligned with the circumferential vessel direction. Circumferential loading resulted in mode I-dominated failure with multiple deflections of the fracture path. The aorta ruptured at a principal Green-Lagrange strain of approximately 0.7, and strain rate peaks that develop ahead of the crack tip reached nearly 400 times the strain rate on average over the test specimen. It required approximately 70% more external work to fracture the aorta by circumferential than axial load; normalised with the fracture surface, similar energy levels are, however, observed. The symconCT test resulted in a stable fracture propagation, which, combined with DIC, provided a set-up for the in-depth analysis of vascular tissue failure. The high strain rates ahead of the crack tip indicate the significance of rate effects in the constitutive description of vascular tissue fracture. STATEMENT OF SIGNIFICANCE: This paper represents a significant step forward in understanding the fracture properties of porcine aorta. Inspired by the Compact Tension test, we developed an ad hoc experimental protocol to investigate stable crack propagation in soft materials, providing new insights into the mechanical processes that lead to the rupture of vascular tissue. The set-up enables the assessment of strains and strain rates ahead of the crack tip, and our findings could improve the clinical risk assessment of vascular pathologies as well as optimize medical device design.
Collapse
Affiliation(s)
- Marta Alloisio
- Solid Mechanics, Department of Engineering Mechanics, KTH Royal Institute of Technology, Sweden
| | - Marina Chatziefraimidou
- Solid Mechanics, Department of Engineering Mechanics, KTH Royal Institute of Technology, Sweden
| | - Joy Roy
- Department of Molecular Medicine and Surgery, KI Karolinska Institute, Sweden
| | - T Christian Gasser
- Solid Mechanics, Department of Engineering Mechanics, KTH Royal Institute of Technology, Sweden.
| |
Collapse
|
5
|
Is location a significant parameter in the layer dependent dissection properties of the aorta? Biomech Model Mechanobiol 2022; 21:1887-1901. [PMID: 36057051 DOI: 10.1007/s10237-022-01627-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2021] [Accepted: 08/07/2022] [Indexed: 11/02/2022]
Abstract
Proper characterisation of biological tissue is key to understanding the effect of the biomechanical environment in the physiology and pathology of the cardiovascular system. Aortic dissection in particular is a prevalent and sometimes fatal disease that still lacks a complete comprehension of its progression. Its development and outcome, however, depend on the location in the vessel. Dissection properties of arteries are frequently studied via delamination tests, such as the T-peel test and the mixed-mode peel test. So far, a study that performs both tests throughout different locations of the aorta, as well as dissecting several interfaces, is missing. This makes it difficult to extract conclusions in terms of vessel heterogeneity, as a standardised experimental procedure cannot be assured for different studies in literature. Therefore, both dissection tests have been here performed on healthy porcine aortas, dissecting three interfaces of the vessels, i.e., the intima-media, the media-adventitia and the media within itself, considering different locations of the aorta, the ascending thoracic aorta (ATA), the descending thoracic aorta and the infrarenal abdominal aorta (IAA). Significant differences were found for both, layers and location. In particular, dissection forces in the ATA were the highest and the separation of the intima-media interface required significantly the lowest force. Moreover, dissection in the longitudinal direction of the vessel generally required more force than in the circumferential one. These results emphasise the need to characterise aortic tissue considering the specific location and dissected layer of the vessel.
Collapse
|
6
|
Filho J, Xavier J, Nunes L. An Alternative Digital Image Correlation-Based Experimental Approach to Estimate Fracture Parameters in Fibrous Soft Materials. MATERIALS 2022; 15:ma15072413. [PMID: 35407748 PMCID: PMC8999918 DOI: 10.3390/ma15072413] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/12/2022] [Revised: 03/22/2022] [Accepted: 03/23/2022] [Indexed: 11/16/2022]
Abstract
One of the main challenges in experimental fracture mechanics is to correctly estimate fracture parameters of a nonhomogeneous and nonlinear material under large deformation. The crack tip detection is strongly affected by fibers at crack tip, leading to inaccurate measures. To overcome this limitation, a novel methodology based on the Digital Image Correlation (DIC) method for crack tip detection of fibrous soft composites is proposed in this work. The unidirectional composite was manufactured using a matrix of polydimethylsiloxane reinforced with a single layer of extensible cotton knit fabric. For two different fiber orientations, the crack growth (da), Crack Tip Opening Displacement (CTOD) and Crack Tip Opening Angle (CTOA) were determined using pure shear specimens under mode I fracture. A consistent estimation of fracture parameters was obtained. The location of the crack tip position during the fracture test using the DIC-based methodology was validated against a visual inspection approach. Results indicated that the DIC-based methodology is easily replicable, precise and robust.
Collapse
Affiliation(s)
- João Filho
- Laboratory of Opto-Mechanics (LOM), Department of Mechanical Engineering (PGMEC-TEM), Universidade Federal Fluminense (UFF), Rua Passo da Pátria, 156, Bloco E, Sala 210, Rio de Janeiro 24210-240, Brazil;
- Correspondence: (J.F.); (J.X.)
| | - José Xavier
- Research and Development Unit for Mechanical and Industrial Engineering (UNIDEMI), Department of Mechanical and Industrial Engineering, NOVA School of Science and Technology, NOVA University Lisbon, 2825-149 Lisbon, Portugal
- Correspondence: (J.F.); (J.X.)
| | - Luiz Nunes
- Laboratory of Opto-Mechanics (LOM), Department of Mechanical Engineering (PGMEC-TEM), Universidade Federal Fluminense (UFF), Rua Passo da Pátria, 156, Bloco E, Sala 210, Rio de Janeiro 24210-240, Brazil;
| |
Collapse
|
7
|
Fereidoonnezhad B, Dwivedi A, Johnson S, McCarthy R, McGarry P. Blood clot fracture properties are dependent on red blood cell and fibrin content. Acta Biomater 2021; 127:213-228. [PMID: 33812070 DOI: 10.1016/j.actbio.2021.03.052] [Citation(s) in RCA: 46] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2020] [Revised: 03/19/2021] [Accepted: 03/23/2021] [Indexed: 12/20/2022]
Abstract
Thrombus fragmentation during endovascular stroke treatment, such as mechanical thrombectomy, leads to downstream emboli, resulting in poor clinical outcomes. Clinical studies suggest that fragmentation risk is dependent on clot composition. This current study presents the first experimental characterization of the composition-dependent fracture properties of blood clots, in addition to the development of a predictive model for blood clot fragmentation. A bespoke experimental test-rig and compact tension specimen fabrication has been developed to measure fracture toughness of thrombus material. Fracture tests are performed on three physiologically relevant clot compositions: a high-fibrin clot made from a 5% haematocrit (H) blood mixture, a medium-fibrin clot made form a 20% H blood mixture, a low-fibrin clot made from a 40% H blood mixture. Fracture toughness is observed to significantly increase with increasing fibrin content, i.e. red blood cell-rich clots are more prone to tear during loading compared to the fibrin-rich clots. Results also reveal that the mechanical behaviour of clot analogues is significantly different in compression and tension. Finite element cohesive zone modelling of clot fracture experiments show that fibrin fibres become highly aligned in the direction perpendicular to crack propagation, providing a significant toughening mechanism. The results presented in this study provide the first characterization of the composition-dependent fracture behaviour of blood clots and are of key importance for development of next-generation thrombectomy devices and clinical strategies. STATEMENT OF SIGNIFICANCE: This study provides a characterisation of the composition-dependent fracture toughness of blood clots. This entails the development of novel experimental techniques for fabrication and testing of blood clot compact tension fracture specimens. The study also develops cohesive zone models of fracture initiation and propagation in blood clots. Results reveal that the fracture resistance of fibrin-rich clots is significantly higher than red blood cell rich clots. Simulations also reveal that stretching and realignment of the fibrin network should be included in blood clot material models in order to accurately replicate compression-tension asymmetry and fibrin enhanced fracture toughness. The results of this study have potentially important clinical implications in terms of clot fracture risk and secondary embolization during mechanical thrombectomy procedures.
Collapse
|