1
|
Gupta A, Rainu SK, Kaur M, Meena M, Singh N, Jacob J. 1,4-Bis(2-hydroxyethyl)piperazine-derived water-dispersible and antibacterial polyurethane coatings for medical catheters. J Mater Chem B 2025; 13:3350-3364. [PMID: 39925157 DOI: 10.1039/d4tb02227k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/11/2025]
Abstract
To prolong usage and mitigate infections associated with bacterial colonization on medical catheters, the development of water-dispersible polyurethane (PU) coatings with bactericidal properties is desirable. With this objective, we have formulated polyurethane coatings that exhibit both antibacterial activity and water dispersibility. A piperazine-based diol, 1,4-bis(2-hydroxyethyl)piperazine (HEPZ), was synthesized and used as a chain extender in PU synthesis. The PUs were prepared using hexamethylene diisocyanate (HDI), 4,4'-methylene diphenyl diisocyanate (MDI), polyethylene glycol (PEG600), and polypropylene glycol (PPG400), resulting in a series of polyurethanes (PU1-PU4). MDI-containing PUs showed superior tensile strength (3.2-3.6 MPa) and elongation (67-70%) attributable to their higher aromatic content. The PEG600-containing PUs (PU1 and PU3) were alkylated using methyl iodide (MeI) to varying degrees whereby a significant reduction in contact angle from ∼82° to ∼62° was observed, indicating enhanced hydrophilicity. MPU3-D with 72.5% methylation demonstrated the most stable water dispersion with a particle size of ∼190.8 nm and a zeta potential of +49.0 mV. In vitro cytocompatibility studies further revealed that methylated PU3 exhibited higher compatibility (80-90%) compared to methylated PU1 (30-40%). The hemolysis test showed the non-hemolytic behavior of MPU3-D films with a % hemolysis of 0.4 ± (0.2)% making it suitable for coating on medical devices. Additionally, MPU3-D films also demonstrated antibacterial activity against Gram-negative (E. coli) and Gram-positive (S. aureus) bacteria, with zones of inhibition measuring 7 mm and 8 mm, respectively. Also, water-dispersible MPU3-D-based coatings with a hardness of ∼75 A and a thickness of ∼17 μm (as observed through FESEM) showed strong adhesion to PVC catheters, exhibiting an adhesion strength of 4B rating. Our results suggest that water-dispersible polyurethane coatings with antibacterial properties are promising materials to reduce catheter-associated infections and enhance patient care.
Collapse
Affiliation(s)
- Anchal Gupta
- Department of Materials Science and Engineering, Indian Institute of Technology, Delhi, New Delhi, 110016, India.
| | - Simran Kaur Rainu
- Centre for Biomedical Engineering, Indian Institute of Technology, Delhi, New Delhi, 110016, India
| | - Manleen Kaur
- Centre for Biomedical Engineering, Indian Institute of Technology, Delhi, New Delhi, 110016, India
| | - Mahipal Meena
- Department of Materials Science and Engineering, Indian Institute of Technology, Delhi, New Delhi, 110016, India.
- Centre for Fire, Explosive and Environment Safety, DRDO, Delhi, 110054, India
| | - Neetu Singh
- Centre for Biomedical Engineering, Indian Institute of Technology, Delhi, New Delhi, 110016, India
| | - Josemon Jacob
- Department of Materials Science and Engineering, Indian Institute of Technology, Delhi, New Delhi, 110016, India.
| |
Collapse
|
2
|
Fu H, Crosby AJ. Measuring interfacial strength of ultra-soft materials with needle-induced cavitation. SOFT MATTER 2025; 21:1662-1668. [PMID: 39902550 DOI: 10.1039/d4sm01203h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2025]
Abstract
Needle-induced cavitation (NIC) has been used to characterize the mechanical properties of ultra-soft biological tissues. Previous studies conducted NIC on brain tissue and computed the energy to separate, or fracture, interfaces between regions from the measured NIC critical pressure. These tests revealed the intrinsic correlation between the critical pressure and the interfacial properties. While NIC demonstrated its potential for measuring interfacial properties, independent measurements have not been made to validate the measurements. In this work, we use model interfaces to validate the use of NIC to quantify the interfacial energy of buried interfaces. By inserting a needle into the interface and inducing pressurized separation, we obtained the critical pressure dependence on the needle size and a known residual stress. At the extrapolated residual stress-free state, we obtained the interfacial energy (Gc) by considering energy dissipated in the separation initiation at the critical pressure point, yielding a Gc value that matches an independent measurement.
Collapse
Affiliation(s)
- Hongbo Fu
- Polymer Science & Engineering Department, University of Massachusetts Amherst, Amherst, MA 01003, USA.
| | - Alfred J Crosby
- Polymer Science & Engineering Department, University of Massachusetts Amherst, Amherst, MA 01003, USA.
| |
Collapse
|
3
|
Zhao J, Zhang H, Ling Z, An Z, Xiao S, Wang P, Fu Z, Shao J, Sun Y, Fu W. A bilayer bioengineered patch with sequential dual-growth factor release to promote vascularization in bladder reconstruction. Regen Biomater 2024; 11:rbae083. [PMID: 39077683 PMCID: PMC11286312 DOI: 10.1093/rb/rbae083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2024] [Revised: 06/15/2024] [Accepted: 06/25/2024] [Indexed: 07/31/2024] Open
Abstract
Bladder tissue engineering holds promise for addressing bladder defects resulting from congenital or acquired bladder diseases. However, inadequate vascularization significantly impacts the survival and function of engineered tissues after transplantation. Herein, a novel bilayer silk fibroin (BSF) scaffold was fabricated with the capability of vascular endothelial growth factor (VEGF) and platelet derived growth factor-BB (PDGF-BB) sequential release. The outer layer of the scaffold was composed of compact SF film with waterproofness to mimic the serosa of the bladder. The inner layer was constructed of porous SF matrix incorporated with SF microspheres (MS) loaded with VEGF and PDGF-BB. We found that the 5% (w/v) MS-incorporated scaffold exhibited a rapid release of VEGF, whereas the 0.2% (w/v) MS-incorporated scaffold demonstrated a slow and sustained release of PDGF-BB. The BSF scaffold exhibited good biocompatibility and promoted endothelial cell migration, tube formation and enhanced endothelial differentiation of adipose derived stem cells (ADSCs) in vitro. The BSF patch was constructed by seeding ADSCs on the BSF scaffold. After in vivo transplantation, not only could the BSF patch facilitate the regeneration of urothelium and smooth muscle, but more importantly, stimulate the regeneration of blood vessels. This study demonstrated that the BSF patch exhibited excellent vascularization capability in bladder reconstruction and offered a viable functional bioengineered patch for future clinical studies.
Collapse
Affiliation(s)
- Jian Zhao
- Medical School of PLA, Beijing 100853, China
- Department of Urology, The Third Medical Center, PLA General Hospital, Beijing 100039, China
- Department of Urology, 960th Hospital of PLA, Jinan 250031, China
| | - Haoqian Zhang
- Inner Mongolia Medical University, Hohhot, Inner Mongolia 010050, China
| | - Zhengyun Ling
- Department of Urology, The Third Medical Center, PLA General Hospital, Beijing 100039, China
- School of Medicine, Nankai University, Tianjin 300071, China
| | - Ziyan An
- Medical School of PLA, Beijing 100853, China
- Department of Urology, The Third Medical Center, PLA General Hospital, Beijing 100039, China
| | - Shuwei Xiao
- Department of Urology, Air Force Medical Center, Beijing 100142, China
| | - Pengchao Wang
- Department of Urology, The Third Medical Center, PLA General Hospital, Beijing 100039, China
| | - Zhouyang Fu
- Department of Urology, The Third Medical Center, PLA General Hospital, Beijing 100039, China
| | - Jinpeng Shao
- Medical School of PLA, Beijing 100853, China
- Department of Urology, The Third Medical Center, PLA General Hospital, Beijing 100039, China
| | - Yanfeng Sun
- Department of Pediatrics, The Third Medical Center, PLA General Hospital, Beijing 100039, China
| | - Weijun Fu
- Department of Urology, The Third Medical Center, PLA General Hospital, Beijing 100039, China
| |
Collapse
|
4
|
Jitsuhiro A, Maeda T, Ogawa A, Yamada S, Konoeda Y, Maruyama H, Endo F, Kitagawa M, Tanimoto K, Hotta A, Tsuji T. Contact-Killing Antibacterial Polystyrene Polymerized Using a Quaternized Cationic Initiator. ACS OMEGA 2024; 9:9803-9812. [PMID: 38434858 PMCID: PMC10905582 DOI: 10.1021/acsomega.3c10233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 01/24/2024] [Accepted: 01/31/2024] [Indexed: 03/05/2024]
Abstract
Contact-killing antibacterial materials are attracting attention owing to their ability for sustained antibacterial activity. However, contact-killing antibacterial polystyrene (PS) has not been extensively studied because its chemically stable structure impedes chemical modification. In this study, we developed an antibacterial PS sheet with a contact-killing surface using PS synthesized from 2,2'-azobis-[2-(1,3-dimethyl-4,5-dihydro-1H-imidazol-3-ium-2-yl)]propane triflate (ADIP) as a radical initiator with cationic moieties. The PS sheet synthesized with ADIP (ADIP-PS) exhibited antibacterial activity in contrast to PS synthesized with other azo radical initiators. Surface ζ-potential measurements revealed that only ADIP-PS had a cationic surface, which contributed to its contact-killing antibacterial activity. The ADIP-PS sheets also exhibited antibacterial activity after washing. In contrast, PS sheets containing silver, a typical leachable antibacterial agent, lost all antibacterial activity after the same washing treatment. The antibacterial ADIP-PS sheet demonstrated strong broad-spectrum activity against both Gram-positive and Gram-negative bacteria, including drug-resistant bacteria. Cytotoxicity tests using L929 cells showed that the ADIP-PS sheets were noncytotoxic. This contact-killing antibacterial PS synthesized with ADIP thus demonstrated good prospects as an easily producible antimicrobial material.
Collapse
Affiliation(s)
- Akiko Jitsuhiro
- Kirin
Central Research Institute, Kirin Holdings Company Limited, 26-1 Muraoka-Higashi 2-Chome, Fujisawa, Kanagawa 251-8555 Japan
| | - Tomoki Maeda
- Frontier
Research Center for Applied Atomic Science, Ibaraki University, 162-1 Shirakata, Tokai-mura, Naka-gun, Ibaraki 319-1106, Japan
- Department
of Mechanical Engineering, Keio University, 3-14-1 Hiyoshi,
Kohoku-ku, Yokohama, Kanagawa 223-8522, Japan
| | - Akiko Ogawa
- Kirin
Central Research Institute, Kirin Holdings Company Limited, 26-1 Muraoka-Higashi 2-Chome, Fujisawa, Kanagawa 251-8555 Japan
| | - Sayuri Yamada
- Kirin
Central Research Institute, Kirin Holdings Company Limited, 26-1 Muraoka-Higashi 2-Chome, Fujisawa, Kanagawa 251-8555 Japan
| | - Yuki Konoeda
- Kirin
Central Research Institute, Kirin Holdings Company Limited, 26-1 Muraoka-Higashi 2-Chome, Fujisawa, Kanagawa 251-8555 Japan
| | - Hiroki Maruyama
- Kirin
Central Research Institute, Kirin Holdings Company Limited, 26-1 Muraoka-Higashi 2-Chome, Fujisawa, Kanagawa 251-8555 Japan
| | - Fuyuaki Endo
- Department
of Mechanical Engineering, Keio University, 3-14-1 Hiyoshi,
Kohoku-ku, Yokohama, Kanagawa 223-8522, Japan
| | - Midori Kitagawa
- Department
of Mechanical Engineering, Keio University, 3-14-1 Hiyoshi,
Kohoku-ku, Yokohama, Kanagawa 223-8522, Japan
| | - Keishi Tanimoto
- Department
of Mechanical Engineering, Keio University, 3-14-1 Hiyoshi,
Kohoku-ku, Yokohama, Kanagawa 223-8522, Japan
| | - Atsushi Hotta
- Department
of Mechanical Engineering, Keio University, 3-14-1 Hiyoshi,
Kohoku-ku, Yokohama, Kanagawa 223-8522, Japan
| | - Toshikazu Tsuji
- Kirin
Central Research Institute, Kirin Holdings Company Limited, 26-1 Muraoka-Higashi 2-Chome, Fujisawa, Kanagawa 251-8555 Japan
| |
Collapse
|
5
|
Chowdhury SR, Mondal G, Ratnayake P, Basu B. Three-Dimensional Extrusion Printed Urinary Specific Grafts: Mechanistic Insights into Buildability and Biophysical Properties. ACS Biomater Sci Eng 2024; 10:1040-1061. [PMID: 38294204 DOI: 10.1021/acsbiomaterials.3c01422] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2024]
Abstract
The compositional formulations and the optimization of process parameters to fabricate hydrogel scaffolds with urological tissue-mimicking biophysical properties are not yet extensively explored, including a comprehensive assessment of a spectrum of properties, such as mechanical strength, viscoelasticity, antimicrobial property, and cytocompatibility. While addressing this aspect, the present work provides mechanistic insights into process science, to produce shape-fidelity compliant alginate-based biomaterial ink blended with gelatin and synthetic nanocellulose. The composition-dependent pseudoplasticity, viscoelasticity, thixotropy, and gel stability over a longer duration in physiological context have been rationalized in terms of intermolecular hydrogen bonding interactions among the biomaterial ink constituents. By varying the hybrid hydrogel ink composition within a narrow compositional window, the resulting hydrogel closely mimics the natural urological tissue-like properties, including tensile stretchability, compressive strength, and biophysical properties. Based on the printability assessment using a critical analysis of gel strength, we have established the buildability of the acellular hydrogel ink and have been successful in fabricating shape-fidelity compliant urological patches or hollow cylindrical grafts using 3D extrusion printing. Importantly, the new hydrogel formulations with good hydrophilicity, support fibroblast cell proliferation and inhibit the growth of Gram-negative E. coli bacteria. These attributes were rationalized in terms of nanocellulose-induced physicochemical changes on the scaffold surface. Taken together, the present study uncovers the process-science-based understanding of the 3D extrudability of the newly formulated alginate-gelatin-nanocellulose-based hydrogels with urological tissue-specific biophysical, cytocompatibility, and antibacterial properties.
Collapse
Affiliation(s)
- Sulob Roy Chowdhury
- Materials Research Centre, Indian Institute of Science, Bangalore 560012, India
| | - Garga Mondal
- Materials Research Centre, Indian Institute of Science, Bangalore 560012, India
| | - Praneeth Ratnayake
- Materials Research Centre, Indian Institute of Science, Bangalore 560012, India
| | - Bikramjit Basu
- Materials Research Centre, Indian Institute of Science, Bangalore 560012, India
| |
Collapse
|
6
|
Duan L, Wang Z, Fan S, Wang C, Zhang Y. Research progress of biomaterials and innovative technologies in urinary tissue engineering. Front Bioeng Biotechnol 2023; 11:1258666. [PMID: 37645598 PMCID: PMC10461011 DOI: 10.3389/fbioe.2023.1258666] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2023] [Accepted: 08/02/2023] [Indexed: 08/31/2023] Open
Abstract
Substantial interests have been attracted to multiple bioactive and biomimetic biomaterials in recent decades because of their ability in presenting a structural and functional reconstruction of urinary tissues. Some innovative technologies have also been surging in urinary tissue engineering and urological regeneration by providing insights into the physiological behavior of the urinary system. As such, the hierarchical structure and tissue function of the bladder, urethra, and ureter can be reproduced similarly to the native urinary tissues. This review aims to summarize recent advances in functional biomaterials and biomimetic technologies toward urological reconstruction. Various nanofirous biomaterials derived from decellularized natural tissues, synthetic biopolymers, and hybrid scaffolds were developed with desired microstructure, surface chemistry, and mechanical properties. Some growth factors, drugs, as well as inorganic nanomaterials were also utilized to enhance the biological activity and functionality of scaffolds. Notably, it is emphasized that advanced approaches, such as 3D (bio) printing and organoids, have also been developed to facilitate structural and functional regeneration of the urological system. So in this review, we discussed the fabrication strategies, physiochemical properties, and biofunctional modification of regenerative biomaterials and their potential clinical application of fast-evolving technologies. In addition, future prospective and commercial products are further proposed and discussed.
Collapse
Affiliation(s)
- Liwei Duan
- The Second Hospital, Jilin University, Changchun, China
| | - Zongliang Wang
- Key Laboratory of Polymer Ecomaterials, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, China
| | - Shuang Fan
- The Second Hospital, Jilin University, Changchun, China
| | - Chen Wang
- The Second Hospital, Jilin University, Changchun, China
| | - Yi Zhang
- The Second Hospital, Jilin University, Changchun, China
| |
Collapse
|
7
|
Budrienė S, Kochanė T, Žurauskaitė N, Balčiūnas E, Rinkūnaitė I, Jonas K, Širmenis R, Bukelskienė V, Baltriukienė D. Synthesis and characterization of UV curable biocompatible hydrophilic copolymers containing siloxane units. JOURNAL OF BIOMATERIALS SCIENCE. POLYMER EDITION 2023:1-20. [PMID: 36651136 DOI: 10.1080/09205063.2023.2170141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
Tissues are highly three-dimensional structure complexes composed of different cell types and their interactions. One of the main challenges in tissue engineering is the inability to produce large, highly perfused scaffolds in which cells can grow at a high cell density and viability. Poly(dimethyl siloxane) (PDMS) is used as a flexible, biocompatible cell culture substrate with tunable mechanical properties. However, its fragility and hydrophobicity still pose a challenge. Here, we present a new strategy for the three-step one-pot synthesis of novel biocompatible hydrophilic copolymers containing siloxane units. In the first step, free radical copolymerization of acrylic acid (AA), butyl methacrylate (BMA), and 2-hydroxyethyl methacrylate (HEMA) was carried out in dioxane (DO) solution in the presence of 2,2'-azodiisobutyronitrile (AIBN). In the second step, the copolymers were modified with diepoxypropoxypropyl-terminated polydimethylsiloxane (DE-PDMS), and in the third step, the copolymers were additionally modified with glycidyl methacrylate (GMA). The modified copolymers were characterized by FTIR, NMR spectroscopy and elemental analysis. Films of modified copolymers were prepared by UV curing. SEM studies revealed microphase separated morphology with distribution of PDMS domains. The mechanical properties of the films depended on the amount of incorporated silicone modifier. The films were more hydrophilic than PDMS films. All novel copolymers showed high biocompatibility.
Collapse
Affiliation(s)
- Saulutė Budrienė
- Faculty of Chemistry and Geosciences, Vilnius University, Vilnius, Lithuania
| | - Tatjana Kochanė
- Faculty of Chemistry and Geosciences, Vilnius University, Vilnius, Lithuania
| | - Neringa Žurauskaitė
- Faculty of Chemistry and Geosciences, Vilnius University, Vilnius, Lithuania
| | - Evaldas Balčiūnas
- Institute of Biochemistry, Life Sciences Center, Vilnius University, Vilnius, Lithuania
| | - Ieva Rinkūnaitė
- Institute of Biochemistry, Life Sciences Center, Vilnius University, Vilnius, Lithuania
| | - Karolis Jonas
- Institute of Biochemistry, Life Sciences Center, Vilnius University, Vilnius, Lithuania
| | - Raimondas Širmenis
- Institute of Biochemistry, Life Sciences Center, Vilnius University, Vilnius, Lithuania
| | - Virginija Bukelskienė
- Institute of Biochemistry, Life Sciences Center, Vilnius University, Vilnius, Lithuania
| | - Daiva Baltriukienė
- Institute of Biochemistry, Life Sciences Center, Vilnius University, Vilnius, Lithuania
| |
Collapse
|
8
|
Polysiloxane-Based Polyurethanes with High Strength and Recyclability. Int J Mol Sci 2022; 23:ijms232012613. [PMID: 36293466 PMCID: PMC9604122 DOI: 10.3390/ijms232012613] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Revised: 10/13/2022] [Accepted: 10/15/2022] [Indexed: 11/16/2022] Open
Abstract
Polysiloxanes have attracted considerable attention in biomedical engineering, owing to their inherent properties, including good flexibility and biocompatibility. However, their low mechanical strength limits their application scope. In this study, we synthesized a polysiloxane-based polyurethane by chemical copolymerization. A series of thermoplastic polysiloxane-polyurethanes (Si-TPUs) was synthesized using hydroxyl-terminated polydimethylsiloxane containing two carbamate groups at the tail of the polymer chains 4,4′-dicyclohexylmethane diisocyanate (HMDI) and 1,4-butanediol as raw materials. The effects of the hard-segment content and soft-segment number average molecular weight on the properties of the resulting TPUs were investigated. The prepared HMDI-based Si-TPUs exhibited good microphase separation, excellent mechanical properties, and acceptable repeatable processability. The tensile strength of SiTPU-2K-39 reached 21.5 MPa, which is significantly higher than that of other flexible polysiloxane materials. Moreover, the tensile strength and breaking elongation of SiTPU-2K-39 were maintained at 80.9% and 94.6%, respectively, after three cycles of regeneration. The Si-TPUs prepared in this work may potentially be used in gas separation, medical materials, antifouling coatings, and other applications.
Collapse
|
9
|
Sharma S, Mandhani A, Basu B. Contact-Active Layer-by-Layer Grafted TPU/PDMS Blends as an Antiencrustation and Antibacterial Platform for Next-Generation Urological Biomaterials: Validation in Artificial and Human Urine. ACS Biomater Sci Eng 2022; 8:4497-4523. [PMID: 36094424 DOI: 10.1021/acsbiomaterials.2c00455] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
Urinary tract infections and urinary encrustation impede the long-term clinical performance of urological implants and medical devices. Together, biofilm formation and encrustation constitute serious complications, driving the development of next-generation urological biomaterials. The currently available bioengineered solutions have limited success during long-term usage in the urinary environment. In addressing this unmet clinical challenge, contact-active, antiencrustation surface grafting were conceived onto a dynamically cross-linked polydimethylsiloxane (PDMS) modified thermoplastic polyurethane (TPU) blend using the layer-by-layer (LbL) assembly route. To the best of the authors' knowledge, the present study is the first to investigate the LbL grafting in developing an antiencrustation platform. These multilayered assemblies strategically employed covalent cross-linking and electrostatic interaction-assisted progressive depositions of branched polyethyleneimine and poly(2-ethyl-2-oxazoline). While polyethyleneimine conferred the contact-killing bactericidal activity, the much-coveted antiencrustation properties were rendered by incorporating a partially hydrolyzed derivative of poly(2-ethyl-2-oxazoline). The performance of the resultant surface-modified TPU/PDMS blends was benchmarked against the conventional urological alloplasts, in a customized lab-scale bioreactor-based dynamic encrustation study and in human urine. After 6 weeks of exposure to an artificial urine medium, simulating urease-positive bacterial infection, the surface-modified blends exhibited a remarkable ability to suppress Ca and Mg encrustation. In addition, these blends also displayed superior grafting stability and antibacterial efficacy against common uropathogens. As high as 4-fold log reduction in the planktonic growth of Gram-negative P. mirabilis and Gram-positive MRSA was recorded with the LbL platform vis-à-vis medical-grade TPU. In conjunction, the in vitro cellular assessment with human keratinocytes (HaCaT) and human embryonic kidney cells (HEK) established the uncompromised cytocompatibility of the multilayered grafted blends. Finally, the physiologically relevant functionality of the LbL grafting has been validated using clinical samples of human urine collected from 129 patients with a broad spectrum of disease conditions. The phase-I pre-clinical study, entailing 6 week-long incubation in human urine, demonstrated significantly improved encrustation resistance of the blends. The collective findings of the present work clearly establish the success of LbL strategies in the development of stable, multifunctional new-generation urological biomaterials.
Collapse
Affiliation(s)
- Swati Sharma
- Materials Research Centre, Indian Institute of Science, Bangalore 560012, India
| | - Anil Mandhani
- Department of Urology and Kidney Transplant, Fortis Memorial Research Institute, Gurugram 122002, India
| | - Bikramjit Basu
- Materials Research Centre, Indian Institute of Science, Bangalore 560012, India.,Center for Biosystems Science and Engineering, Indian Institute of Science, Bangalore 560012, India
| |
Collapse
|
10
|
Da LC, Sun Y, Lin YH, Chen SZ, Chen GX, Zheng BH, Du SR. Emerging Bioactive Agent Delivery-Based Regenerative Therapies for Lower Genitourinary Tissues. Pharmaceutics 2022; 14:1718. [PMID: 36015344 PMCID: PMC9414065 DOI: 10.3390/pharmaceutics14081718] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 08/05/2022] [Accepted: 08/12/2022] [Indexed: 11/20/2022] Open
Abstract
Injury to lower genitourinary (GU) tissues, which may result in either infertility and/or organ dysfunctions, threatens the overall health of humans. Bioactive agent-based regenerative therapy is a promising therapeutic method. However, strategies for spatiotemporal delivery of bioactive agents with optimal stability, activity, and tunable delivery for effective sustained disease management are still in need and present challenges. In this review, we present the advancements of the pivotal components in delivery systems, including biomedical innovations, system fabrication methods, and loading strategies, which may improve the performance of delivery systems for better regenerative effects. We also review the most recent developments in the application of these technologies, and the potential for delivery-based regenerative therapies to treat lower GU injuries. Recent progress suggests that the use of advanced strategies have not only made it possible to develop better and more diverse functionalities, but also more precise, and smarter bioactive agent delivery systems for regenerative therapy. Their application in lower GU injury treatment has achieved certain effects in both patients with lower genitourinary injuries and/or in model animals. The continuous evolution of biomaterials and therapeutic agents, advances in three-dimensional printing, as well as emerging techniques all show a promising future for the treatment of lower GU-related disorders and dysfunctions.
Collapse
Affiliation(s)
- Lin-Cui Da
- Center of Reproductive Medicine, Fujian Maternity and Child Health Hospital College of Clinical Medicine for Obstetrics & Gynecology and Pediatrics, Fujian Medical University, Fuzhou 350001, China
| | - Yan Sun
- Center of Reproductive Medicine, Fujian Maternity and Child Health Hospital College of Clinical Medicine for Obstetrics & Gynecology and Pediatrics, Fujian Medical University, Fuzhou 350001, China
| | - Yun-Hong Lin
- Center of Reproductive Medicine, Fujian Maternity and Child Health Hospital College of Clinical Medicine for Obstetrics & Gynecology and Pediatrics, Fujian Medical University, Fuzhou 350001, China
| | - Su-Zhu Chen
- Center of Reproductive Medicine, Fujian Maternity and Child Health Hospital College of Clinical Medicine for Obstetrics & Gynecology and Pediatrics, Fujian Medical University, Fuzhou 350001, China
| | - Gang-Xin Chen
- Center of Reproductive Medicine, Fujian Maternity and Child Health Hospital College of Clinical Medicine for Obstetrics & Gynecology and Pediatrics, Fujian Medical University, Fuzhou 350001, China
| | - Bei-Hong Zheng
- Center of Reproductive Medicine, Fujian Maternity and Child Health Hospital College of Clinical Medicine for Obstetrics & Gynecology and Pediatrics, Fujian Medical University, Fuzhou 350001, China
| | - Sheng-Rong Du
- Center of Reproductive Medicine, Fujian Maternity and Child Health Hospital College of Clinical Medicine for Obstetrics & Gynecology and Pediatrics, Fujian Medical University, Fuzhou 350001, China
- The Key Laboratory of Innate Immune Biology of Fujian Province, Biomedical Research Center of South China, College of Life Sciences, Fujian Normal University, Fuzhou 350117, China
| |
Collapse
|
11
|
Sharma S, Basu B. Biomaterials assisted reconstructive urology: The pursuit of an implantable bioengineered neo-urinary bladder. Biomaterials 2021; 281:121331. [PMID: 35016066 DOI: 10.1016/j.biomaterials.2021.121331] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Revised: 12/14/2021] [Accepted: 12/24/2021] [Indexed: 12/27/2022]
Abstract
Urinary bladder is a dynamic organ performing complex physiological activities. Together with ureters and urethra, it forms the lower urinary tract that facilitates urine collection, low-pressure storage, and volitional voiding. However, pathological disorders are often liable to cause irreversible damage and compromise the normal functionality of the bladder, necessitating surgical intervention for a reconstructive procedure. Non-urinary autologous grafts, primarily derived from gastrointestinal tract, have long been the gold standard in clinics to augment or to replace the diseased bladder tissue. Unfortunately, such treatment strategy is commonly associated with several clinical complications. In absence of an optimal autologous therapy, a biomaterial based bioengineered platform is an attractive prospect revolutionizing the modern urology. Predictably, extensive investigative research has been carried out in pursuit of better urological biomaterials, that overcome the limitations of conventional gastrointestinal graft. Against the above backdrop, this review aims to provide a comprehensive and one-stop update on different biomaterial-based strategies that have been proposed and explored over the past 60 years to restore the dynamic function of the otherwise dysfunctional bladder tissue. Broadly, two unique perspectives of bladder tissue engineering and total alloplastic bladder replacement are critically discussed in terms of their status and progress. While the former is pivoted on scaffold mediated regenerative medicine; in contrast, the latter is directed towards the development of a biostable bladder prosthesis. Together, these routes share a common aspiration of designing and creating a functional equivalent of the bladder wall, albeit, using fundamentally different aspects of biocompatibility and clinical needs. Therefore, an attempt has been made to systematically analyze and summarize the evolution of various classes as well as generations of polymeric biomaterials in urology. Considerable emphasis has been laid on explaining the bioengineering methodologies, pre-clinical and clinical outcomes. Some of the unaddressed challenges, including vascularization, innervation, hollow 3D prototype fabrication and urinary encrustation, have been highlighted that currently delay the successful commercial translation. More importantly, the rapidly evolving and expanding concepts of bioelectronic medicine are discussed to inspire future research efforts towards the further advancement of the field. At the closure, crucial insights are provided to forge the biomaterial assisted reconstruction as a long-term therapeutic strategy in urological practice for patients' care.
Collapse
Affiliation(s)
- Swati Sharma
- Laboratory for Biomaterials, Materials Research Centre, Indian Institute of Science, Bangalore, 560012, India
| | - Bikramjit Basu
- Laboratory for Biomaterials, Materials Research Centre, Indian Institute of Science, Bangalore, 560012, India; Centre for Biosystems Science and Engineering, Indian Institute of Science, Bangalore, 560012, India.
| |
Collapse
|
12
|
Panda AK, Basu B. Functionalized Fluoropolymer-Compatibilized Elastomeric Bilayer Composites for Osteochondral Repair: Unraveling the Role of Substrate Stiffness and Functionalities. ACS APPLIED BIO MATERIALS 2021; 4:8543-8558. [PMID: 35005914 DOI: 10.1021/acsabm.1c01021] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
The osteochondral lesions and osteoarthritis-related complications continue to be clinically relevant challenges to be addressed by the biomaterials community. Hydrogel-based scaffolds have been widely investigated to enhance osteochondral regeneration, but the inferior mechanical properties together with poor functional stability are the major constraints in their clinical translation. The development of osteochondral implants with natural tissue-mimicking mechanical properties remains largely unexplored. In this perspective, the present study demonstrates a strategy to develop a bilayer osteochondral implant with an elastically stiff composite (poly(vinylidene difluoride)-reinforced BaTiO3, PVDF/BT) and elastically compliant composite (maleic anhydride-functionalized PVDF/thermoplastic polyurethane/BaTiO3, m-PVDF/TPU/BT). The compositional variation in polymer composites allowed the elastic modulus of the hybrid bilayer construct to vary from ∼2 GPa to ∼90 MPa, which enabled a better understanding of the substrate-stiffness-dependent cellular behavior and maturation of preosteoblasts and chondrocytes. The cellular functionalities on PVDF-based polymer matrices have been benchmarked against ultrahigh-molecular-weight polyethylene (UHMWPE), which is clinically used for a wide spectrum of orthopedic applications. The increased alkaline phosphatase (ALP) activity, collagen synthesis, and matrix mineralization confirmed the early differentiation of preosteoblasts on the PVDF/BT matrix with subchondral bone-like mechanical properties. On the contrary, the upregulated chondrogenic functionalities were recorded on m-PVDF/TPU/BT with an elevated level of collagen content, glycosaminoglycans, and proteoglycans. Emphasis has been laid on probing the regulation of the osteochondral behavior using tailored substrate stiffness and functionalities using compatibilized fluoropolymer-based elastomeric composites. Taken together, the results of this work conclusively establish the efficacy of the hybrid bilayer composite with natural tissue-mimicking mechanical properties for the functional repair of osteochondral defects.
Collapse
Affiliation(s)
- Asish Kumar Panda
- Laboratory for Biomaterials, Materials Research Centre, Indian Institute of Science, Bangalore, Bangalore 560012, India
| | - Bikramjit Basu
- Laboratory for Biomaterials, Materials Research Centre, Indian Institute of Science, Bangalore, Bangalore 560012, India.,Centre for Biosystems Science and Engineering, Indian Institute of Science, Bangalore, Bangalore 560012, India
| |
Collapse
|
13
|
Song F, Kong Y, Shao C, Cheng Y, Lu J, Tao Y, Du J, Wang H. Chitosan-based multifunctional flexible hemostatic bio-hydrogel. Acta Biomater 2021; 136:170-183. [PMID: 34610476 DOI: 10.1016/j.actbio.2021.09.056] [Citation(s) in RCA: 93] [Impact Index Per Article: 23.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2021] [Revised: 09/04/2021] [Accepted: 09/29/2021] [Indexed: 12/17/2022]
Abstract
Realizing the potential application of chitosan as an effective biomedical hemostatic agent has become an emerging research hotspot. However, fabricating a flexible chitosan-based hemostatic bio-hydrogel with self-adhesion feature in humid conditions and rapid hemostasis capability remains a challenge. Herein, we reported the development of chitosan-based hydrogels (DCS-PEGSH gels) with typical multilevel pore structures, which were cross-linked by 3-(3,4-dihydroxyphenyl) propionic acid-modified chitosan (DCS) and sebacic acid-terminated polyethylene glycol modified by p-hydroxybenzaldehyde (PEGSH). By precisely regulating the proportion of PEGSH, the fabricated bio-hydrogels displayed favorable cytocompatibility, suitable stretchability (∼780%), and blood absorbability (1300% ± 50%). Moreover, the strong adhesion (∼68.5 kPa) of the assembled bio-hydrogel ensured its firm adherence on pigskin and on bleeding wound in both static and dynamic humid environments without shedding, thus providing a long service life. The fabricated hydrogels exhibited shorter blood clotting time (50 s) and lower blood clotting index (BCI, 41) than the commercial chitosan sponge (288 s, BCI 65). Notably, the amount of blood loss from the liver in mice was reduced by almost 90% as compared to that for the control group. This study paves a solid way for developing a chitosan-based hydrogel with self-adhesive, self-healing, stretchability, biocompatibility, and antibacterial and antioxidant properties through molecular design and structural regulation, which will enable the biomedical application of chitosan in emergency hemostasis, particularly in joints and extremities. STATEMENT OF SIGNIFICANCE: The design and preparation of multifunctional integrated green adhesive bio-hydrogels while avoiding the use of organic solvents and toxic chemical reagents has been an emerging challenge. Herein, a flexible chitosan-based hemostatic bio-hydrogel that integrates multifunctional properties was successfully synthesized. The bio-hydrogel displayed suitable stretchability (780%) and blood absorbability (1300% ± 50%). Moreover, the strong adhesion (68.5 kPa) ensured firm adherence of the assembled hydrogel on pigskin and on the bleeding wound site in both static and dynamic humid environments without shedding, thus providing a long service life. In addition, the designed hydrogel showed good compatibility and antibacterial performance. The dynamic Schiff base endowed the bio-hydrogel with excellent self-healing performance without any external stimuli.
Collapse
|
14
|
Abstract
Tissue engineering could play a major role in the setting of urinary diversion. Several conditions cause the functional or anatomic loss of urinary bladder, requiring reconstructive procedures on the urinary tract. Three main approaches are possible: (i) incontinent cutaneous diversion, such as ureterocutaneostomy, colonic or ileal conduit, (ii) continent pouch created using different segments of the gastrointestinal system and a cutaneous stoma, and (iii) orthotopic urinary diversion with an intestinal segment with spherical configuration and anastomosis to the urethra (neobladder, orthotopic bladder substitution). However, urinary diversions are associated with numerous complications, such as mucus production, electrolyte imbalances and increased malignant transformation potential. In this context, tissue engineering would have the fundamental role of creating a suitable material for urinary diversion, avoiding the use of bowel segments, and reducing complications. Materials used for the purpose of urinary substitution are biological in case of acellular tissue matrices and naturally derived materials, or artificial in case of synthetic polymers. However, only limited success has been achieved so far. The aim of this review is to present the ideal properties of a urinary tissue engineered scaffold and to examine the results achieved so far. The most promising studies have been highlighted in order to guide the choice of scaffolds and cells type for further evolutions.
Collapse
|
15
|
Dieterle MP, Husari A, Steinberg T, Wang X, Ramminger I, Tomakidi P. From the Matrix to the Nucleus and Back: Mechanobiology in the Light of Health, Pathologies, and Regeneration of Oral Periodontal Tissues. Biomolecules 2021; 11:824. [PMID: 34073044 PMCID: PMC8228498 DOI: 10.3390/biom11060824] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Revised: 05/25/2021] [Accepted: 05/27/2021] [Indexed: 02/07/2023] Open
Abstract
Among oral tissues, the periodontium is permanently subjected to mechanical forces resulting from chewing, mastication, or orthodontic appliances. Molecularly, these movements induce a series of subsequent signaling processes, which are embedded in the biological concept of cellular mechanotransduction (MT). Cell and tissue structures, ranging from the extracellular matrix (ECM) to the plasma membrane, the cytosol and the nucleus, are involved in MT. Dysregulation of the diverse, fine-tuned interaction of molecular players responsible for transmitting biophysical environmental information into the cell's inner milieu can lead to and promote serious diseases, such as periodontitis or oral squamous cell carcinoma (OSCC). Therefore, periodontal integrity and regeneration is highly dependent on the proper integration and regulation of mechanobiological signals in the context of cell behavior. Recent experimental findings have increased the understanding of classical cellular mechanosensing mechanisms by both integrating exogenic factors such as bacterial gingipain proteases and newly discovered cell-inherent functions of mechanoresponsive co-transcriptional regulators such as the Yes-associated protein 1 (YAP1) or the nuclear cytoskeleton. Regarding periodontal MT research, this review offers insights into the current trends and open aspects. Concerning oral regenerative medicine or weakening of periodontal tissue diseases, perspectives on future applications of mechanobiological principles are discussed.
Collapse
Affiliation(s)
- Martin Philipp Dieterle
- Center for Dental Medicine, Division of Oral Biotechnology, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetterstr. 55, 79106 Freiburg, Germany; (M.P.D.); (X.W.); (I.R.); (P.T.)
| | - Ayman Husari
- Center for Dental Medicine, Department of Orthodontics, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetterstr. 55, 79106 Freiburg, Germany;
- Faculty of Engineering, University of Freiburg, Georges-Köhler-Allee 101, 79110 Freiburg, Germany
| | - Thorsten Steinberg
- Center for Dental Medicine, Division of Oral Biotechnology, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetterstr. 55, 79106 Freiburg, Germany; (M.P.D.); (X.W.); (I.R.); (P.T.)
| | - Xiaoling Wang
- Center for Dental Medicine, Division of Oral Biotechnology, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetterstr. 55, 79106 Freiburg, Germany; (M.P.D.); (X.W.); (I.R.); (P.T.)
| | - Imke Ramminger
- Center for Dental Medicine, Division of Oral Biotechnology, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetterstr. 55, 79106 Freiburg, Germany; (M.P.D.); (X.W.); (I.R.); (P.T.)
| | - Pascal Tomakidi
- Center for Dental Medicine, Division of Oral Biotechnology, Medical Center—University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetterstr. 55, 79106 Freiburg, Germany; (M.P.D.); (X.W.); (I.R.); (P.T.)
| |
Collapse
|