1
|
McCarthy CM, Allardyce JM, Hickey SE, Walsh MT, McGourty KD, Mulvihill JJE. Comparison of macroscale and microscale mechanical properties of fresh and fixed-frozen porcine colonic tissue. J Mech Behav Biomed Mater 2023; 138:105599. [PMID: 36462287 DOI: 10.1016/j.jmbbm.2022.105599] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Revised: 11/21/2022] [Accepted: 11/23/2022] [Indexed: 11/27/2022]
Abstract
Mechanical changes to the microenvironment of the extracellular matrix (ECM) in tissue have been hypothesised to elicit a pathogenic response in the surrounding cells. Hence, 3D scaffolds are a popular method of studying cellular behaviour under conditions that mimic in vivo microenvironment. To create a 3D biomimetic scaffold that captures the in vivo ECM microenvironment a robust mechanical characterisation of the whole ECM at the microscale is necessary. This study examined the multiscale methods of characterising the ECM microenvironment using porcine colon tissue. To facilitate fresh tissue microscale mechanical characterisation, a protocol for sectioning fresh, unfixed, soft biological tissue was developed. Four experiments examined both the microscale and macroscale mechanics of both fresh (Fr) and fixed-frozen (FF) porcine colonic tissue using microindentation for microscale testing and uniaxial compression testing for macroscale testing. The results obtained in this study show a significant difference in elastic modulus between Fr and FF tissue at both the macroscale and microscale. There was an order of magnitude difference between the Fr and FF tissue at the microscale between each of the three layers of the colon tested i.e. the muscularis propria (MP), the submucosa (SM) and the mucosa (M). Macroscale testing cannot capture these regional differences. The findings in this study suggest that the most appropriate method for mechanically characterising the ECM is fresh microscale mechanical microindentation. These methods can be used on a range of biological tissues to create 3D biomimetic scaffolds that are more representative of the in vivo ECM, allowing for a more in-depth characterisation of the disease process.
Collapse
Affiliation(s)
- Clíona M McCarthy
- Biomaterials Cluster, Bernal Institute, University of Limerick, Limerick, Ireland; School of Engineering, University of Limerick, Limerick, Ireland
| | - Joanna M Allardyce
- School of Allied Health, University of Limerick, Ireland; Health Research Institute, University of Limerick, Ireland
| | - Séamus E Hickey
- Biomaterials Cluster, Bernal Institute, University of Limerick, Limerick, Ireland; School of Chemical Sciences, University of Limerick, Ireland
| | - Michael T Walsh
- Biomaterials Cluster, Bernal Institute, University of Limerick, Limerick, Ireland; School of Engineering, University of Limerick, Limerick, Ireland; Health Research Institute, University of Limerick, Ireland
| | - Kieran D McGourty
- Biomaterials Cluster, Bernal Institute, University of Limerick, Limerick, Ireland; School of Chemical Sciences, University of Limerick, Ireland; Health Research Institute, University of Limerick, Ireland
| | - John J E Mulvihill
- Biomaterials Cluster, Bernal Institute, University of Limerick, Limerick, Ireland; School of Engineering, University of Limerick, Limerick, Ireland; Health Research Institute, University of Limerick, Ireland.
| |
Collapse
|
2
|
Ultrasonic microrheology for ex vivo skin explants monitoring: A proof of concept. Biosens Bioelectron 2022; 198:113831. [PMID: 34864245 DOI: 10.1016/j.bios.2021.113831] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2021] [Revised: 10/13/2021] [Accepted: 11/19/2021] [Indexed: 11/20/2022]
Abstract
As an answer to alternative non-animal testing, biosensors dedicated to the ex vivo skin explants monitoring are a challenge to study physiological-like behavior and optimize new topical products. Because of the skin viscoelastic behavior, mechanical tests are commonly based on macroscopic measurement and give global descriptors of its state. Other techniques, including photoacoustic ones, are more focused on the molecular scale. There is a gap to fill in the mesoscopic range to get information about the microstructure of the skin. This article presents the proof-of-concept of a biosensor coupling a thickness shear-mode transducer with human skin explants kept in life-like state for a week. Thanks to a multifrequency analysis of the transducer impedance, this biosensor is able to monitor the viscoelastic properties of the skin. To extract the complex shear modulus and the microstructural evolutions, a mechanical model based on fractional calculus is used. As a preliminary results, the sensitivity of the sensor to probe the skin viscoelasticity in lifelike state and the impact of its culture medium are presented. A suitable microstructural coefficient is also extracted in order to identify mechanical breaches in the skin barrier after the application of peeling products.
Collapse
|