1
|
Thirunavukarasu AJ, Morales-Wong F, Halim NSH, Han E, Koh SK, Zhou L, Kocaba V, Venkatraman S, Mehta JS, Riau AK. Nanohydroxyapatite Coating Attenuates Fibrotic and Immune Responses to Promote Keratoprosthesis Biointegration in Advanced Ocular Surface Disorders. ACS APPLIED MATERIALS & INTERFACES 2024; 16:25892-25908. [PMID: 38740379 PMCID: PMC11129699 DOI: 10.1021/acsami.4c04077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/12/2024] [Revised: 04/17/2024] [Accepted: 04/18/2024] [Indexed: 05/16/2024]
Abstract
Keratoprosthesis (KPro) implantation is frequently the only recourse for patients with severe corneal disease. However, problems arise due to inadequate biointegration of the KPro, particularly the PMMA optical cylinder, such as tissue detachment, tissue melting, or eye-threatening infection in the interface. Here, using the AuroKPro as a model prosthesis, a surface functionalization approach─coating the optical cylinder with nanohydroxyapatite (nHAp)─was trialed in rabbit eyes with and without a proceeding chemical injury. In chemically injured eyes, which simulated total limbal epithelial stem cell deficiency, clear benefits were conferred by the coating. The total modified Hackett-McDonald score and area of tissue apposition differences 12 weeks after implantation were 5.0 and 22.5%, respectively. Mechanical push-in tests revealed that 31.8% greater work was required to detach the tissues. These differences were less marked in uninjured eyes, which showed total score and tissue apposition differences of 2.5 and 11.5%, respectively, and a work difference of 23.5%. The improved biointegration could be contributed by the attenuated expression of fibronectin (p = 0.036), collagen 3A1 (p = 0.033), and α-smooth muscle actin (p = 0.045)─proteins typically upregulated during nonadherent fibrous capsule envelopment of bioinert material─adjacent to the optical cylinders. The coating also appeared to induce a less immunogenic milieu in the ocular surface tissue, evidenced by the markedly lower expression of tear proteins associated with immune and stimulus responses. Collectively, the level of these tear proteins in eyes with coated prostheses was 1.1 ± 13.0% of naïve eyes: substantially lower than with noncoated KPros (246.5 ± 79.3% of naïve, p = 0.038). Together, our results indicated that nHAp coating may reduce the risk of prosthesis failure in severely injured eyes, which are representative of the cohort of KPro patients.
Collapse
Affiliation(s)
- Arun J. Thirunavukarasu
- Tissue
Engineering and Cell Therapy Group, Singapore
Eye Research Institute, Singapore 169856, Singapore
- Oxford
University Clinical Academic Graduate School, University of Oxford, Oxford OX3 9DU, United
Kingdom
| | - Fernando Morales-Wong
- Tissue
Engineering and Cell Therapy Group, Singapore
Eye Research Institute, Singapore 169856, Singapore
- Singapore
National Eye Centre, Singapore 168751, Singapore
- Autonomous
University of Nuevo Leon, San Nicolas
de los Garza, Nuevo Leon 66455, Mexico
| | | | - Evelina Han
- Tissue
Engineering and Cell Therapy Group, Singapore
Eye Research Institute, Singapore 169856, Singapore
| | - Siew Kwan Koh
- Ocular
Proteomics Group, Singapore Eye Research
Institute, Singapore 169856, Singapore
| | - Lei Zhou
- Department
of Applied Biology and Chemical Technology, Hong Kong Polytechnic University, Hung Hom, Hong Kong
- Centre
for Eye and Vision Research, Shatin, Hong Kong
| | - Viridiana Kocaba
- Tissue
Engineering and Cell Therapy Group, Singapore
Eye Research Institute, Singapore 169856, Singapore
| | - Subramanian Venkatraman
- Department
of Materials Science and Engineering, National
University of Singapore, Singapore 117575, Singapore
- iHealthTech, National University of Singapore, Singapore 117599, Singapore
| | - Jodhbir S. Mehta
- Tissue
Engineering and Cell Therapy Group, Singapore
Eye Research Institute, Singapore 169856, Singapore
- Singapore
National Eye Centre, Singapore 168751, Singapore
- Ophthalmology
and Visual Sciences Academic Clinical Programme, Duke-NUS Medical School, Singapore 169857, Singapore
| | - Andri K. Riau
- Tissue
Engineering and Cell Therapy Group, Singapore
Eye Research Institute, Singapore 169856, Singapore
- Ophthalmology
and Visual Sciences Academic Clinical Programme, Duke-NUS Medical School, Singapore 169857, Singapore
| |
Collapse
|
2
|
Chan JS, Han E, Lim CHL, Kurz AC, Shuman J, Liu YC, Riau AK, Mehta JS. Incisional surface quality of electron-beam irradiated cornea-extracted lenticule for stromal keratophakia: high nJ-energy vs. low nJ-energy femtosecond laser. Front Med (Lausanne) 2023; 10:1289528. [PMID: 38162883 PMCID: PMC10754972 DOI: 10.3389/fmed.2023.1289528] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Accepted: 11/20/2023] [Indexed: 01/03/2024] Open
Abstract
Introduction Corneal lenticules can be utilized as an additive material for stromal keratophakia. However, following extraction, they must be reimplanted almost immediately or cryopreserved in lenticule banks. Electron-beam (E-beam) irradiated corneas permit room-temperature storage for up to 2 years, enabling keratophakia to be performed on demand. This study aims to compare the performance of high nano Joule (nJ)-energy (VisuMax) and low nJ-energy (FEMTO LDV) femtosecond laser systems on the thickness consistency and surface quality and collagen morphology of lenticules produced from fresh and E-beamed corneas. Methods A total of 24 lenticules with -6.00 dioptre power were cut in fresh human donor corneas and E-beamed corneas with VisuMax and FEMTO LDV. Before extraction, the thickness of the lenticules was measured with anterior segment-optical coherence tomography (AS-OCT). The incisional surface roughness of extracted lenticules was analyzed using atomic force microscopy (AFM) and scanning electron microscopy (SEM). Multiphoton microscopy was then used to assess the surface collagen morphometry. Results The E-beamed lenticules that were cut using FEMTO LDV were significantly thicker than the fresh specimens as opposed to those created with VisuMax, which had a similar thickness as the fresh lenticules. On the vertex, they were ∼11% thicker than the fresh lenticules. The surface roughness (Rq) of E-beamed lenticules incised with FEMTO LDV did not differ significantly from the fresh lenticules. This contrasted with the VisuMax-fashioned lenticules, which showed notably smoother surfaces (∼36 and ∼20% lower Rq on anterior and posterior surfaces, respectively) on the E-beamed than the fresh lenticules. The FEMTO LDV induced less cumulative changes to the collagen morphology on the surfaces of both fresh and E-beamed lenticules than the VisuMax. Conclusion It has been previously demonstrated that the low nJ-energy FEMTO LDV produced a smoother cutting surface compared to high nJ-energy VisuMax in fresh lenticules. Here, we showed that this effect was also seen in the E-beamed lenticules. In addition, lower laser energy conferred fewer changes to the lenticular surface collagen morphology. The smaller disparity in surface cutting quality and collagen disturbances on the E-beamed lenticules could be beneficial for the early visual recovery of patients who undergo stromal keratophakia.
Collapse
Affiliation(s)
- Jian S. Chan
- School of Clinical Medicine, University of New South Wales, Sydney, NSW, Australia
- Department of Ophthalmology, National University Health System, Singapore, Singapore
| | - Evelina Han
- Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore, Singapore
| | - Chris H. L. Lim
- School of Clinical Medicine, University of New South Wales, Sydney, NSW, Australia
- Department of Ophthalmology, National University Health System, Singapore, Singapore
- Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | | | - Jeremy Shuman
- Lions World Vision Institute, Tampa, FL, United States
| | - Yu-Chi Liu
- Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore, Singapore
- Ophthalmology and Visual Sciences Academic Clinical Programme, Duke-NUS Medical School, Singapore, Singapore
- Singapore National Eye Centre, Singapore, Singapore
| | - Andri K. Riau
- Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore, Singapore
- Ophthalmology and Visual Sciences Academic Clinical Programme, Duke-NUS Medical School, Singapore, Singapore
| | - Jodhbir S. Mehta
- Tissue Engineering and Cell Therapy Group, Singapore Eye Research Institute, Singapore, Singapore
- Ophthalmology and Visual Sciences Academic Clinical Programme, Duke-NUS Medical School, Singapore, Singapore
- Singapore National Eye Centre, Singapore, Singapore
| |
Collapse
|