Bae IH, Park DS, Lee SY, Jang EJ, Shim JW, Lim KS, Park JK, Kim JH, Sim DS, Jeong MH. Bilirubin coating attenuates the inflammatory response to everolimus-coated stents. J Biomed Mater Res B Appl Biomater 2017; 106:1486-1495. [PMID: 28691192 DOI: 10.1002/jbm.b.33955] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2017] [Revised: 05/24/2017] [Accepted: 06/21/2017] [Indexed: 12/23/2022]
Abstract
The aim of this study was to evaluate the effects of bilirubin- and/or everolimus (EVL)-coated stents to prevent arterial neointimal hyperplasia and inflammation in vitro and in vivo. The stents were prepared by spray coating bare metal stents (BMS) with bilirubin and/or EVL. Study groups were divided into (1) BMS, (2) bilirubin-coated stents (BES), (3) commercialized stents (Synergy™; EES), and (4) bilirubin/EVL-coated stents (B-EES). The coating thickness and drug release rates were comparable to previous reports (i.e., <4 µm thickness and 50% drug release in 7 days). Smooth muscle cell migration was inhibited in both EVL-containing groups (20.5 ± 3.80% in EES and 18.4 ± 2.55% in B-EES) compared to the non-EVL-containing groups (78.0 ± 6.41% in BMS and 76.1 ± 4.88% in BES) (n = 10, p < 0.05). Stents were randomly implanted to 40 coronary arteries in 20 pigs and subjected to various analyses after 4 weeks of implantation. As results, the inflammation score was dramatically increased in the EES group (2.1 ± 0.42) compared to that of the other groups (1.5 ± 0.55, 1.3 ± 0.23, and 1.5 ± 0.27 for BMS, BES, and B-EES, respectively, n = 10, p < 0.05). Immunofluorescence analysis revealed that inflammation was prevented in the bilirubin-containing groups (BES and B-EES). However, the percent area of restenosis was decreased in the EVL-containing groups (20.5 ± 4.11% for EES and 18.4 ± 3.61% for B-EES) compared to the non-EVL-containing groups (32.3 ± 6.41% for BMS and 29.6 ± 5.95% for BES, n = 10, p < 0.05). The percent areas of restenosis determined by histopathology, optical coherence tomography, and micro-computed tomography were consistent. In addition, the stent was barely covered in the EES and B-EES groups at 4 weeks postimplantation. These dual drug-coated stents may be especially beneficial to patients who have an increased risk of inflammation. These stents have great potential for use in cardiovascular applications. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1486-1495, 2018.
Collapse
Affiliation(s)
- In-Ho Bae
- The Cardiovascular Convergence Research Center of Chonnam National University Hospital Designated by Korea wMinistry of Health and Welfare, Gwangju, 501-757, Republic of Korea.,Korea Cardiovascular Stent Research Institute, Jangsung, 501-893, Republic of Korea
| | - Dae Sung Park
- The Cardiovascular Convergence Research Center of Chonnam National University Hospital Designated by Korea wMinistry of Health and Welfare, Gwangju, 501-757, Republic of Korea.,Korea Cardiovascular Stent Research Institute, Jangsung, 501-893, Republic of Korea
| | - So-Youn Lee
- The Cardiovascular Convergence Research Center of Chonnam National University Hospital Designated by Korea wMinistry of Health and Welfare, Gwangju, 501-757, Republic of Korea.,Korea Cardiovascular Stent Research Institute, Jangsung, 501-893, Republic of Korea
| | - Eun-Jae Jang
- The Cardiovascular Convergence Research Center of Chonnam National University Hospital Designated by Korea wMinistry of Health and Welfare, Gwangju, 501-757, Republic of Korea.,Korea Cardiovascular Stent Research Institute, Jangsung, 501-893, Republic of Korea
| | - Jae-Won Shim
- The Cardiovascular Convergence Research Center of Chonnam National University Hospital Designated by Korea wMinistry of Health and Welfare, Gwangju, 501-757, Republic of Korea.,Korea Cardiovascular Stent Research Institute, Jangsung, 501-893, Republic of Korea
| | - Kyung-Seob Lim
- The Cardiovascular Convergence Research Center of Chonnam National University Hospital Designated by Korea wMinistry of Health and Welfare, Gwangju, 501-757, Republic of Korea
| | - Jun-Kyu Park
- Department of Polymer Science and Engineering, Sunchon National University, Suncheon, 540-950, Republic of Korea
| | - Ju Han Kim
- Korea Cardiovascular Stent Research Institute, Jangsung, 501-893, Republic of Korea.,Department of Cardiology, Chonnam National University Hospital, Gwangju, 501-757, Republic of Korea
| | - Doo Sun Sim
- The Cardiovascular Convergence Research Center of Chonnam National University Hospital Designated by Korea wMinistry of Health and Welfare, Gwangju, 501-757, Republic of Korea.,Department of Cardiology, Chonnam National University Hospital, Gwangju, 501-757, Republic of Korea
| | - Myung Ho Jeong
- The Cardiovascular Convergence Research Center of Chonnam National University Hospital Designated by Korea wMinistry of Health and Welfare, Gwangju, 501-757, Republic of Korea.,Korea Cardiovascular Stent Research Institute, Jangsung, 501-893, Republic of Korea.,Department of Cardiology, Chonnam National University Hospital, Gwangju, 501-757, Republic of Korea
| |
Collapse
|
2
|
Reviakine I, Jung F, Braune S, Brash JL, Latour R, Gorbet M, van Oeveren W. Stirred, shaken, or stagnant: What goes on at the blood-biomaterial interface. Blood Rev 2016; 31:11-21. [PMID: 27478147 DOI: 10.1016/j.blre.2016.07.003] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2016] [Revised: 07/08/2016] [Accepted: 07/12/2016] [Indexed: 01/15/2023]
Abstract
There is a widely recognized need to improve the performance of vascular implants and external medical devices that come into contact with blood by reducing adverse reactions they cause, such as thrombosis and inflammation. These reactions lead to major adverse cardiovascular events such as heart attacks and strokes. Currently, they are managed therapeutically. This need remains unmet by the biomaterials research community. Recognized stagnation of the blood-biomaterial interface research translates into waning interest from clinicians, funding agencies, and practitioners of adjacent fields. The purpose of this contribution is to stir things up. It follows the 2014 BloodSurf meeting (74th International IUVSTA Workshop on Blood-Biomaterial Interactions), offers reflections on the situation in the field, and a three-pronged strategy integrating different perspectives on the biological mechanisms underlying blood-biomaterial interactions. The success of this strategy depends on reengaging clinicians and on the renewed cooperation of the funding agencies to support long-term efforts.
Collapse
Affiliation(s)
- Ilya Reviakine
- Institute of Functional Interfaces (IFG), Karlsruhe Institute of Technology (KIT), Hermann von Helmholtz Platz 1, 76344 Eggenstein-Leopoldshafen, Germany; Department of Bioengineering, University of Washington, Seattle, WA 98105, USA.
| | - Friedrich Jung
- Institute of Biomaterial Science and Berlin-Brandenburg Centre for Regenerative Therapies (BCRT), Helmholtz Zentrum Geesthacht, Kantstrasse 55, 14513 Teltow, Germany
| | - Steffen Braune
- Institute of Biomaterial Science and Berlin-Brandenburg Centre for Regenerative Therapies (BCRT), Helmholtz Zentrum Geesthacht, Kantstrasse 55, 14513 Teltow, Germany
| | - John L Brash
- Department of Chemical Engineering, School of Biomedical Engineering, McMaster University, Hamilton, Ontario, L8S 4L8, Canada
| | - Robert Latour
- Rhodes Engineering Research Center, Department of Bioengineering, Clemson University, Clemson, SC 29634, USA
| | - Maud Gorbet
- Department of Systems Design Engineering, Biomedical Engineering, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada
| | - Wim van Oeveren
- HaemoScan, Stavangerweg 23-23, 9723JC Groningen, The Netherlands
| |
Collapse
|