1
|
Kim K, Narsinh K, Ozhinsky E. Technical advances in motion-robust MR thermometry. Magn Reson Med 2024; 92:15-27. [PMID: 38501903 PMCID: PMC11132643 DOI: 10.1002/mrm.30057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Revised: 01/25/2024] [Accepted: 01/27/2024] [Indexed: 03/20/2024]
Abstract
Proton resonance frequency shift (PRFS) MR thermometry is the most common method used in clinical thermal treatments because of its fast acquisition and high sensitivity to temperature. However, motion is the biggest obstacle in PRFS MR thermometry for monitoring thermal treatment in moving organs. This challenge arises because of the introduction of phase errors into the PRFS calculation through multiple methods, such as image misregistration, susceptibility changes in the magnetic field, and intraframe motion during MRI acquisition. Various approaches for motion correction have been developed for real-time, motion-robust, and volumetric MR thermometry. However, current technologies have inherent trade-offs among volume coverage, processing time, and temperature accuracy. These tradeoffs should be considered and chosen according to the thermal treatment application. In hyperthermia treatment, precise temperature measurements are of increased importance rather than the requirement for exceedingly high temporal resolution. In contrast, ablation procedures require robust temporal resolution to accurately capture a rapid temperature rise. This paper presents a comprehensive review of current cutting-edge MRI techniques for motion-robust MR thermometry, and recommends which techniques are better suited for each thermal treatment. We expect that this study will help discern the selection of motion-robust MR thermometry strategies and inspire the development of motion-robust volumetric MR thermometry for practical use in clinics.
Collapse
Affiliation(s)
- Kisoo Kim
- Department of Radiology & Biomedical Imaging, University of California, San Francisco, California, USA
| | - Kazim Narsinh
- Department of Radiology & Biomedical Imaging, University of California, San Francisco, California, USA
| | - Eugene Ozhinsky
- Department of Radiology & Biomedical Imaging, University of California, San Francisco, California, USA
| |
Collapse
|
2
|
Bouzid A, Chidami S, Lailler TQ, García AC, Ould-Bachir T, Chaouki J. Innovative Non-Invasive and Non-Intrusive Precision Thermometry in Stainless-Steel Tanks Using Ultrasound Transducers. SENSORS (BASEL, SWITZERLAND) 2024; 24:3404. [PMID: 38894194 PMCID: PMC11174446 DOI: 10.3390/s24113404] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2024] [Revised: 05/10/2024] [Accepted: 05/23/2024] [Indexed: 06/21/2024]
Abstract
Measuring temperature inside chemical reactors is crucial to ensuring process control and safety. However, conventional methods face a number of limitations, such as the invasiveness and the restricted dynamic range. This paper presents a novel approach using ultrasound transducers to enable accurate temperature measurements. Our experiments, conducted within a temperature range of 28.8 to 83.8 °C, reveal a minimal temperature accuracy of 98.6% within the critical zone spanning between 70.5 and 75 °C, and an accuracy of over 99% outside this critical zone. The experiments focused on a homogeneous environment of distilled water within a stainless-steel tank. This approach will be extended in a future research in order to diversify the experimental media and non-uniform environments, while promising broader applications in chemical process monitoring and control.
Collapse
Affiliation(s)
- Ahmed Bouzid
- MOTCE Laboratory, Department of Computer Engineering, Polytechnique Montréal, Montreal, QC H3T 1J4, Canada;
- PEARL Laboratory, Department of Chemical Engineering, Polytechnique Montréal, Montreal, QC H3T 1J4, Canada; (S.C.); (A.C.G.); (J.C.)
| | - Saad Chidami
- PEARL Laboratory, Department of Chemical Engineering, Polytechnique Montréal, Montreal, QC H3T 1J4, Canada; (S.C.); (A.C.G.); (J.C.)
| | - Tristan Quentin Lailler
- MOTCE Laboratory, Department of Computer Engineering, Polytechnique Montréal, Montreal, QC H3T 1J4, Canada;
| | - Adrián Carrillo García
- PEARL Laboratory, Department of Chemical Engineering, Polytechnique Montréal, Montreal, QC H3T 1J4, Canada; (S.C.); (A.C.G.); (J.C.)
| | - Tarek Ould-Bachir
- MOTCE Laboratory, Department of Computer Engineering, Polytechnique Montréal, Montreal, QC H3T 1J4, Canada;
| | - Jamal Chaouki
- PEARL Laboratory, Department of Chemical Engineering, Polytechnique Montréal, Montreal, QC H3T 1J4, Canada; (S.C.); (A.C.G.); (J.C.)
| |
Collapse
|
3
|
Verghese G, Voroslakos M, Markovic S, Tal A, Dehkharghani S, Yaghmazadeh O, Alon L. Autonomous animal heating and cooling system for temperature-regulated magnetic resonance experiments. NMR IN BIOMEDICINE 2024; 37:e5046. [PMID: 37837254 PMCID: PMC10840815 DOI: 10.1002/nbm.5046] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Revised: 09/05/2023] [Accepted: 09/06/2023] [Indexed: 10/15/2023]
Abstract
Temperature is a hallmark parameter influencing almost all magnetic resonance properties (e.g., T1 , T2 , proton density, and diffusion). In the preclinical setting, temperature has a large influence on animal physiology (e.g., respiration rate, heart rate, metabolism, and oxidative stress) and needs to be carefully regulated, especially when the animal is under anesthesia and thermoregulation is disrupted. We present an open-source heating and cooling system capable of regulating the temperature of the animal. The system was designed using Peltier modules capable of heating or cooling a circulating water bath with active temperature feedback. Feedback was obtained using a commercial thermistor, placed in the animal rectum, and a proportional-integral-derivative controller was used to modulate the temperature. Its operation was demonstrated in a phantom as well as in mouse and rat animal models, where the standard deviation of the temperature of the animal upon convergence was less than a 10th of a degree. An application where brain temperature of a mouse was modulated was demonstrated using an invasive optical probe and noninvasive magnetic resonance spectroscopic thermometry measurements.
Collapse
Affiliation(s)
- George Verghese
- Center for Advanced Imaging Innovation and Research (CAIR), New York University School of Medicine, New York, NY, United States
- Center for Biomedical Imaging, New York University School of Medicine, New York, NY, United States
| | | | - Stefan Markovic
- Department of Chemical Physics, Weizmann Institute of Science, Rehovot, Israel
| | - Assaf Tal
- Department of Chemical Physics, Weizmann Institute of Science, Rehovot, Israel
| | - Seena Dehkharghani
- Center for Advanced Imaging Innovation and Research (CAIR), New York University School of Medicine, New York, NY, United States
- Center for Biomedical Imaging, New York University School of Medicine, New York, NY, United States
| | | | - Leeor Alon
- Center for Advanced Imaging Innovation and Research (CAIR), New York University School of Medicine, New York, NY, United States
- Center for Biomedical Imaging, New York University School of Medicine, New York, NY, United States
| |
Collapse
|
4
|
Choquet K, Vappou J, Cabras P, Ishak O, Gangi A, Breton E. Magnetic Resonance Acoustic Radiation Force Imaging (MR-ARFI) for the monitoring of High Intensity Focused Ultrasound (HIFU) ablation in anisotropic tissue. MAGMA (NEW YORK, N.Y.) 2023; 36:737-747. [PMID: 36723689 DOI: 10.1007/s10334-023-01062-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Revised: 01/06/2023] [Accepted: 01/10/2023] [Indexed: 02/02/2023]
Abstract
OBJECTIVE We introduce a non-invasive MR-Acoustic Radiation Force Imaging (ARFI)-based elastography method that provides both the local shear modulus and temperature maps for the monitoring of High Intensity Focused Ultrasound (HIFU) therapy. MATERIALS AND METHODS To take tissue anisotropy into account, the local shear modulus μ is determined in selected radial directions around the focal spot by fitting the phase profiles to a linear viscoelastic model, including tissue-specific mechanical relaxation time τ. MR-ARFI was evaluated on a calibrated phantom, then applied to the monitoring of HIFU in a gel phantom, ex vivo and in vivo porcine muscle tissue, in parallel with MR-thermometry. RESULTS As expected, the shear modulus polar maps reflected the isotropy of phantoms and the anisotropy of muscle. In the HIFU monitoring experiments, both the shear modulus polar map and the thermometry map were updated with every pair of MR-ARFI phase images acquired with opposite MR-ARFI-encoding. The shear modulus was found to decrease (phantom and ex vivo) or increase (in vivo) during heating, before remaining steady during the cooling phase. The mechanical relaxation time, estimated pre- and post-HIFU, was found to vary in muscle tissue. DISCUSSION MR-ARFI allowed for monitoring of viscoelasticity changes around the HIFU focal spot even in anisotropic muscle tissue.
Collapse
Affiliation(s)
- Karine Choquet
- Université de Strasbourg, CNRS, ICube, UMR 7357, Strasbourg, France.
| | - Jonathan Vappou
- Université de Strasbourg, CNRS, ICube, UMR 7357, Strasbourg, France
| | - Paolo Cabras
- Université de Strasbourg, CNRS, ICube, UMR 7357, Strasbourg, France
- Image Guided Therapy, Pessac, France
| | - Ounay Ishak
- Université de Strasbourg, CNRS, ICube, UMR 7357, Strasbourg, France
| | - Afshin Gangi
- Université de Strasbourg, CNRS, ICube, UMR 7357, Strasbourg, France
- Department of Interventional Imaging, Hôpitaux Universitaires de Strasbourg, Strasbourg, France
| | - Elodie Breton
- Université de Strasbourg, CNRS, ICube, UMR 7357, Strasbourg, France.
| |
Collapse
|
5
|
Abstract
Immunotherapy has revolutionized the treatment of patients with cancer. However, promoting antitumour immunity in patients with tumours that are resistant to these therapies remains a challenge. Thermal therapies provide a promising immune-adjuvant strategy for use with immunotherapy, mostly owing to the capacity to reprogramme the tumour microenvironment through induction of immunogenic cell death, which also promotes the recruitment of endogenous immune cells. Thus, thermal immunotherapeutic strategies for various cancers are an area of considerable research interest. In this Review, we describe the role of the various thermal therapies and provide an update on attempts to combine these with immunotherapies in clinical trials. We also provide an overview of the preclinical development of various thermal immuno-nanomedicines, which are capable of combining thermal therapies with various immunotherapy strategies in a single therapeutic platform. Finally, we discuss the challenges associated with the clinical translation of thermal immuno-nanomedicines and emphasize the importance of multidisciplinary and inter-professional collaboration to facilitate the optimal translation of this technology from bench to bedside.
Collapse
|
6
|
Avoiding Pitfalls in Thermal Dose Effect Relationship Studies: A Review and Guide Forward. Cancers (Basel) 2022; 14:cancers14194795. [PMID: 36230717 PMCID: PMC9562191 DOI: 10.3390/cancers14194795] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Revised: 09/23/2022] [Accepted: 09/26/2022] [Indexed: 11/16/2022] Open
Abstract
The challenge to explain the diffuse and unconclusive message reported by hyperthermia studies investigating the thermal dose parameter is still to be unravelled. In the present review, we investigated a wide range of technical and clinical parameters characterising hyperthermia treatment to better understand and improve the probability of detecting a thermal dose effect relationship in clinical studies. We performed a systematic literature review to obtain hyperthermia clinical studies investigating the associations of temperature and thermal dose parameters with treatment outcome or acute toxicity. Different hyperthermia characteristics were retrieved, and their influence on temperature and thermal dose parameters was assessed. In the literature, we found forty-eight articles investigating thermal dose effect relationships. These comprised a total of 4107 patients with different tumour pathologies. The association between thermal dose and treatment outcome was the investigated endpoint in 90% of the articles, while the correlation between thermal dose and toxicity was investigated in 50% of the articles. Significant associations between temperature-related parameters and treatment outcome were reported in 63% of the studies, while those between temperature-related parameters and toxicity were reported in 15% of the studies. One clear difficulty for advancement is that studies often omitted fundamental information regarding the clinical treatment, and among the different characteristics investigated, thermometry details were seldom and divergently reported. To overcome this, we propose a clear definition of the terms and characteristics that should be reported in clinical hyperthermia treatments. A consistent report of data will allow their use to further continue the quest for thermal dose effect relationships.
Collapse
|
7
|
Gao D, Shi Y, Ni J, Chen S, Wang Y, Zhao B, Song M, Guo X, Ren X, Zhang X, Tian Z, Yang Z. NIR/MRI-Guided Oxygen-Independent Carrier-Free Anti-Tumor Nano-Theranostics. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2022; 18:e2106000. [PMID: 34854571 DOI: 10.1002/smll.202106000] [Citation(s) in RCA: 25] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Indexed: 05/22/2023]
Abstract
Imaging-guided photothermal therapy (PTT)/photodynamic therapy (PDT) for cancer treatment are beneficial for precise localization of the malignant lesions and combination of multiple cell killing mechanisms in eradicating stubborn thermal-resistant cancer cells. However, overcoming the adverse impact of tumor hypoxia on PDT efficacy remains a challenge. Here, carrier-free nano-theranostic agents are developed (AIBME@IR780-APM NPs) for magnetic resonance imaging (MRI)-guided synergistic PTT/thermodynamic therapy (TDT). Two IR780 derivatives are synthesized as the subject of nanomedicine to confer the advantages for the nanomedicine, which are by feat of amphiphilic IR780-PEG to enhance the sterical stability and reduce the risk from reticuloendothelial system uptake, and IR780-ATU to chelate Mn2+ for T1 -weighted MRI. Dimethyl 2,2'-azobis(2-methylpropionate) (AIBME), acting as thermally decomposable radical initiators, are further introduced into nanosystems with the purpose of generating highly cytotoxic alkyl radicals upon PTT launched by IR780 under 808 nm laser irradiation. Therefore, the sequentially generated heat and alkyl radicals synergistically induce cell death via synergistic PTT/TDT, ignoring tumor hypoxia. Moreover, these carrier-free nano-theranostic agents present satisfactory biocompatibility, which could be employed as a powerful weapon to hit hypoxic tumors via MRI-guided oxygen-independent PTT and photonic TDT.
Collapse
Affiliation(s)
- Di Gao
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
| | - Yupeng Shi
- Henan Key laboratory of Functional Magnetic Resonance Imaging and Molecular Imaging Department of MRI, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450000, P. R. China
| | - Jiahua Ni
- School of Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, 02138, USA
| | - Shuojia Chen
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
| | - Ying Wang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
| | - Bin Zhao
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
- Department of Epidemiology, Shaanxi Provincial Tumor Hospital, Xi'an, 710061, P. R. China
| | - Manli Song
- Henan Key laboratory of Functional Magnetic Resonance Imaging and Molecular Imaging Department of MRI, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, 450000, P. R. China
| | - Xiaoqing Guo
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
| | - Xuechun Ren
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
| | - Xingcai Zhang
- School of Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, 02138, USA
| | - Zhongmin Tian
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
| | - Zhe Yang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, 710049, P. R. China
- Research Center of Life Science, Research Institute of Xi'an Jiaotong University, Zhejiang, 311200, P. R. China
| |
Collapse
|
8
|
Kong N, Hu Q, Wu Y, Zhu X. Lanthanide Luminescent Nanocomposite for Non‐Invasive Temperature Monitoring in Vivo. Chemistry 2022; 28:e202104237. [DOI: 10.1002/chem.202104237] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2021] [Indexed: 12/23/2022]
Affiliation(s)
- Na Kong
- School of Physical Science and Technology ShanghaiTech University 393 Middle Huaxia Road Shanghai 201210 P. R. China
| | - Qian Hu
- School of Physical Science and Technology ShanghaiTech University 393 Middle Huaxia Road Shanghai 201210 P. R. China
| | - Yukai Wu
- School of Physical Science and Technology ShanghaiTech University 393 Middle Huaxia Road Shanghai 201210 P. R. China
| | - Xingjun Zhu
- School of Physical Science and Technology ShanghaiTech University 393 Middle Huaxia Road Shanghai 201210 P. R. China
| |
Collapse
|
9
|
Kuroda K, Yatsushiro S. New Insights into MR Safety for Implantable Medical Devices. Magn Reson Med Sci 2022; 21:110-131. [PMID: 35228487 PMCID: PMC9199981 DOI: 10.2463/mrms.rev.2021-0160] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2021] [Accepted: 01/08/2022] [Indexed: 12/24/2022] Open
Abstract
Over the last two decades, the status of MR safety has dramatically changed. In particular, ever since the MR-conditional cardiac device was approved by the Food and Drug Administration (FDA) in 2008 and by the Pharmaceuticals and Medical Devices Agency (PMDA) in 2012, the safety of patients with an implantable medical device (IMD) has been one of the most important issues in terms of MR use. In conjunction with the regulatory approvals for various IMDs, standards, technical specifications, and guidelines have also been rapidly created and developed. Many invaluable papers investigating and reviewing the history and status of MR use in the presence of IMDs already exist. As such, this review paper seeks to bridge the gap between clinical practice and the information that is obtained by standard-based tests and provided by an IMD's package insert or instructions for use. Interpretation of the gradient of the magnetic flux density intensity of the static magnetic field with respect to the magnetic displacement force is discussed, along with the physical background of RF field. The relationship between specific absorption rate (SAR) and B1+RMS, and their effects on image quality are described. In addition, insofar as providing new directions for future research and practice, the feasibility of safety test methods for RF-induced heating of IMDs using MR thermometry, evaluation of tissue heat damage, and challenges in cardiac IMDs will be discussed.
Collapse
Affiliation(s)
- Kagayaki Kuroda
- Department of Human and Information Sciences, School of Information Science and Technology, Tokai University, Hiratsuka, Kanagawa, Japan
| | - Satoshi Yatsushiro
- Department of Human and Information Sciences, School of Information Science and Technology, Tokai University, Hiratsuka, Kanagawa, Japan
- Biosim Laboratory, Bioview, Inc., Tokyo, Japan
| |
Collapse
|
10
|
Ozvat TM, Rappé AK, Zadrozny JM. Isotopomeric Elucidation of the Mechanism of Temperature Sensitivity in 59Co NMR Molecular Thermometers. Inorg Chem 2022; 61:778-785. [PMID: 34962806 PMCID: PMC9531048 DOI: 10.1021/acs.inorgchem.1c03326] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
Understanding the mechanisms governing temperature-dependent magnetic resonance properties is essential for enabling thermometry via magnetic resonance imaging. Herein we harness a new molecular design strategy for thermometry─that of effective mass engineering via deuteration in the first coordination shell─to reveal the mechanistic origin of 59Co chemical shift thermometry. Exposure of [Co(en)3]3+ (1; en = ethylenediamine) and [Co(diNOsar)]3+ (2; diNOsar = dinitrosarcophagine) to mixtures of H2O and D2O produces distributions of [Co(en)3]3+-dn (n = 0-12) and [Co(diNOsar)]3+-dn (n = 0-6) isotopomers all resolvable by 59Co NMR. Variable-temperature 59Co NMR analyses reveal a temperature dependence of the 59Co chemical shift, Δδ/ΔT, on deuteration of the N-donor atoms. For 1, deuteration amplifies Δδ/ΔT by 0.07 ppm/°C. Increasing degrees of deuteration yield an opposing influence on 2, diminishing Δδ/ΔT by -0.07 ppm/°C. Solution-phase Raman spectroscopy in the low-frequency 200-600 cm-1 regime reveals a red shift of Raman-active Co-N6 vibrational modes by deuteration. Analysis of the normal vibrational modes shows that Raman modes produce the largest variation in 59Co δ. Finally, partition function analysis of the Raman-active modes shows that increased populations of Raman modes predict greater Δδ/ΔT, representing new experimental insight into the thermometry mechanism.
Collapse
Affiliation(s)
- Tyler M. Ozvat
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Anthony K. Rappé
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Joseph M. Zadrozny
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| |
Collapse
|
11
|
Liu H, Lu C, Han L, Zhang X, Song G. Optical – Magnetic probe for evaluating cancer therapy. Coord Chem Rev 2021. [DOI: 10.1016/j.ccr.2021.213978] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
12
|
Heinrich A, Schenkl S, Buckreus D, Güttler FV, Teichgräber UKM. CT-based thermometry with virtual monoenergetic images by dual-energy of fat, muscle and bone using FBP, iterative and deep learning-based reconstruction. Eur Radiol 2021; 32:424-431. [PMID: 34327575 PMCID: PMC8660750 DOI: 10.1007/s00330-021-08206-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Accepted: 07/07/2021] [Indexed: 12/24/2022]
Abstract
Objectives The aim of this study was to evaluate the sensitivity of CT-based thermometry for clinical applications regarding a three-component tissue phantom of fat, muscle and bone. Virtual monoenergetic images (VMI) by dual-energy measurements and conventional polychromatic 120-kVp images with modern reconstruction algorithms adaptive statistical iterative reconstruction-Volume (ASIR-V) and deep learning image reconstruction (DLIR) were compared. Methods A temperature-regulating water circuit system was developed for the systematic evaluation of the correlation between temperature and Hounsfield units (HU). The measurements were performed on a Revolution CT with gemstone spectral imaging technology (GSI). Complementary measurements were performed without GSI (voltage 120 kVp, current 130–545 mA). The measured object was a tissue equivalent phantom in a temperature range of 18 to 50°C. The evaluation was carried out for VMI at 40 to 140 keV and polychromatic 120-kVp images. Results The regression analysis showed a significant inverse linear dependency between temperature and average HU regardless of ASIR-V and DLIR. VMI show a higher temperature sensitivity compared to polychromatic images. The temperature sensitivities were 1.25 HU/°C (120 kVp) and 1.35 HU/°C (VMI at 140 keV) for fat, 0.38 HU/°C (120 kVp) and 0.47 HU/°C (VMI at 40 keV) for muscle and 1.15 HU/°C (120 kVp) and 3.58 HU/°C (VMI at 50 keV) for bone. Conclusions Dual-energy with VMI enables a higher temperature sensitivity for fat, muscle and bone. The reconstruction with ASIR-V and DLIR has no significant influence on CT-based thermometry, which opens up the potential of drastic dose reductions. Key Points • Virtual monoenergetic images (VMI) enable a higher temperature sensitivity for fat (8%), muscle (24%) and bone (211%) compared to conventional polychromatic 120-kVp images. • With VMI, there are parameters, e.g. monoenergy and reconstruction kernel, to modulate the temperature sensitivity. In contrast, there are no parameters to influence the temperature sensitivity for conventional polychromatic 120-kVp images. • The application of adaptive statistical iterative reconstruction-Volume (ASIR-V) and deep learning–based image reconstruction (DLIR) has no effect on CT-based thermometry, opening up the potential of drastic dose reductions in clinical applications.
Collapse
Affiliation(s)
- Andreas Heinrich
- Department of Radiology, Jena University Hospital - Friedrich Schiller University, Am Klinikum 1, 07747, Jena, Germany.
| | - Sebastian Schenkl
- Institute of Forensic Medicine, Jena University Hospital - Friedrich Schiller University, Am Klinikum 1, 07747, Jena, Germany
| | - David Buckreus
- Department of Radiology, Jena University Hospital - Friedrich Schiller University, Am Klinikum 1, 07747, Jena, Germany
| | - Felix V Güttler
- Department of Radiology, Jena University Hospital - Friedrich Schiller University, Am Klinikum 1, 07747, Jena, Germany
| | - Ulf K-M Teichgräber
- Department of Radiology, Jena University Hospital - Friedrich Schiller University, Am Klinikum 1, 07747, Jena, Germany
| |
Collapse
|
13
|
Wilson AJ, Rahman M, Kosmas P, Thanou M. Nanomaterials responding to microwaves: an emerging field for imaging and therapy. NANOSCALE ADVANCES 2021; 3:3417-3429. [PMID: 34527861 PMCID: PMC8388194 DOI: 10.1039/d0na00840k] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Accepted: 03/12/2021] [Indexed: 05/05/2023]
Abstract
In recent years, new microwave-based imaging, sensing and hyperthermia applications have emerged in the field of diagnostics and therapy. For diagnosis, this technology involves the application of low power microwaves, utilising contrast between the relative permittivity of tissues to identify pathologies. This contrast can be further enhanced through the implementation of nanomaterials. For therapy, this technology can be applied in tissues either through hyperthermia, which can help anti-cancer drug tumour penetration or as ablation to destroy malignant tissues. Nanomaterials can absorb electromagnetic radiation and can enhance the microwave hyperthermic effect. In this review we aim to introduce this area of renewed interest and provide insights into current developments in its technologies and companion nanoparticles, as well as presenting an overview of applications for diagnosis and therapy.
Collapse
Affiliation(s)
- Annah J Wilson
- School of Cancer & Pharmaceutical Sciences, King's College London, Institute of Pharmaceutical Science Franklin Wilkins Building, 150 Stamford Street London SE1 9NH UK
- Department of Engineering, King's College London UK
| | - Mohammed Rahman
- School of Cancer & Pharmaceutical Sciences, King's College London, Institute of Pharmaceutical Science Franklin Wilkins Building, 150 Stamford Street London SE1 9NH UK
- Department of Engineering, King's College London UK
| | | | - Maya Thanou
- School of Cancer & Pharmaceutical Sciences, King's College London, Institute of Pharmaceutical Science Franklin Wilkins Building, 150 Stamford Street London SE1 9NH UK
| |
Collapse
|
14
|
Dunne M, Evans JC, Dewhirst MW, Allen C. The integration of hyperthermia and drug delivery. Adv Drug Deliv Rev 2020; 163-164:1-2. [PMID: 33308488 DOI: 10.1016/j.addr.2020.11.011] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Revised: 10/19/2020] [Accepted: 10/21/2020] [Indexed: 01/19/2023]
Affiliation(s)
- Michael Dunne
- Leslie Dan Faculty of Pharmacy, University of Toronto, Toronto, ON, Canada
| | - James C Evans
- Leslie Dan Faculty of Pharmacy, University of Toronto, Toronto, ON, Canada
| | - Mark W Dewhirst
- Duke University School of Medicine, Research Drive, Durham, NC, USA
| | - Christine Allen
- Leslie Dan Faculty of Pharmacy, University of Toronto, Toronto, ON, Canada
| |
Collapse
|