1
|
Velagaleti RS, Harrell C, Michalski J, Lefèvre T, Windecker S, Slagboom T, Saito S, Koolen J, Waksman R, Kandzari DE. Impact of preprocedural left ventricular systolic function on the safety and durability of percutaneous coronary intervention. Catheter Cardiovasc Interv 2024; 103:523-531. [PMID: 38440914 DOI: 10.1002/ccd.30995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 02/07/2024] [Accepted: 02/16/2024] [Indexed: 03/06/2024]
Abstract
BACKGROUND Percutaneous coronary intervention (PCI) is considered less safe in patients with reduced ejection fraction (EF), an impression based on older data. Whether the safety and durability of contemporary PCI are different in patients with reduced EF compared with normal EF patients is unknown. METHODS Patients from the BIOFLOW II, IV and V clinical trials were grouped as normal EF (≥50%) and reduced EF (30%-50%). Using multivariable logistic regression and cox proportional hazards regression, we determined relations of EF category with procedural safety (a composite of cardiac death, myocardial infarction, stroke and urgent coronary artery bypass grafting within 30 days of PCI) and target lesion failure (TLF; comprising cardiac death, target vessel myocardial infarction, target vessel revascularization within 1 year of PCI) respectively. In sensitivity analyses, we regrouped patients into EF < 45% and ≥55% and repeated the aforementioned analyses. RESULTS In 1685 patients with normal EF (mean age 65 years; 27% women; mean EF 61%) and 259 with low EF (mean age 64 years; 17% women; mean EF 41%), 101 safety and 148 TLF events occurred. Compared with patients in the normal EF group, those with reduced EF had neither a statistically significant higher proportion of safety events, nor a higher multivariable-adjusted risk for such events. Similarly, patients with reduced EF and normal EF did not differ in terms of TLF event proportions or multivariable-adjusted risk for TLF. The results were similar in sensitivity analyses with EF groups redefined to create a 10% between-group EF separation. CONCLUSION PCI safety and durability outcomes are similar in patients with mild-moderately reduced EF and normal EF.
Collapse
Affiliation(s)
| | | | | | - Thierry Lefèvre
- Department of Interventional Cardiology, Hopital Jacques Cartier, Massy, France
| | - Stephan Windecker
- Department of Cardiology, Bern University Hospital, Bern, Switzerland
| | - Ton Slagboom
- Cardiology Unit, OLVG, Amsterdam, The Netherlands
| | - Shigeru Saito
- Okinawa Tokushukai Shonan Kamakura General Hospital, Kanagawa, Japan
| | | | - Ron Waksman
- Division of Interventional Cardiology, MedStar Cardiovascular Research Network, MedStar Washington Hospital Center, Washington, USA
| | | |
Collapse
|
2
|
Kandzari DE, Koolen JJ, Doros G, Garcia-Garcia HM, Bennett J, Roguin A, Gharib EG, Cutlip DE, Waksman R. Ultrathin Bioresorbable Polymer Sirolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents: BIOFLOW V Final 5-Year Outcomes. JACC Cardiovasc Interv 2022; 15:1852-1860. [PMID: 36137689 DOI: 10.1016/j.jcin.2022.07.027] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/16/2022] [Revised: 06/06/2022] [Accepted: 07/12/2022] [Indexed: 10/14/2022]
Abstract
BACKGROUND Randomized trials have demonstrated the superiority of ultrathin strut drug-eluting stents compared with alternative stent designs. Whether these differences persist over late-term follow-up is uncertain. OBJECTIVES This study sought to compare late-term (5-year) clinical outcomes among patients treated with ultrathin strut (60 µm) bioresorbable polymer sirolimus-eluting stents (BP SES) and thin strut (81 µm) durable polymer everolimus-eluting stents (DP EES). METHODS BIOFLOW V (Biotronik Prospective Randomized Multicenter Study to Assess the Safety and Effectiveness of the Orsiro Sirolimus Eluting Coronary Stent System in the Treatment of Subjects with Up to Three De Novo or Restenotic Coronary Artery Lesions V) was an international, 2:1 randomized trial comparing percutaneous coronary intervention with ultrathin strut BP SES versus thin strut DP EES regarding the primary endpoint of 12-month target lesion failure (TLF). Prespecified outcomes through 5 years were assessed. RESULTS Among 1,334 patients randomized to treatment with BP SES (n = 884) or DP EES (n = 450), the 5-year rates of TLF were 12.3% for BP SES and 15.3% for DP EES (P = 0.108). Revascularization with BP SES was associated with a significantly lower target vessel-related myocardial infarction (6.6% vs 10.3%, P = 0.015) and late/very late definite/probable stent thrombosis (0.3% vs 1.6%, P = 0.021). Ischemia-driven target lesion revascularization was numerically but not significantly lower with BP SES (5.9% vs 7.7%, P = 0.202). Cardiac death rates were 2.6% versus 1.9% (P = 0.495) for BP SES and DP EES, respectively. CONCLUSIONS In a large, randomized trial, TLF and the individual outcomes of cardiac death and target lesion revascularization at 5 years were similar among patients treated with BP SES versus DP EES. Both target vessel-related myocardial infarction and late/very late definite/probable stent thrombosis were significantly lower with BP SES. These results confirm the durability of safety and the effectiveness of percutaneous coronary intervention with ultrathin BP SES.
Collapse
Affiliation(s)
| | | | - Gheorghe Doros
- Department of Biostatistics and Epidemiology, Boston University School of Public Health, Baim Institute for Clinical Research, Boston, Massachusetts, USA
| | - Hector M Garcia-Garcia
- Division of Interventional Cardiology, MedStar Cardiovascular Research Network, MedStar Washington Hospital Center, Washington, DC, USA
| | - Johan Bennett
- Department of Cardiovascular Medicine, University Hospitals Leuven, Leuven, Belgium
| | - Ariel Roguin
- Department of Cardiology, Hillel Yaffe Medical Center, Hadera, Israel
| | - Elie G Gharib
- Charleston Area Medical Center, Charleston, West Virginia, USA
| | - Donald E Cutlip
- Beth Israel Deaconess Medical Center, Baim Institute for Clinical Research, Boston, Massachusetts, USA
| | - Ron Waksman
- Division of Interventional Cardiology, MedStar Cardiovascular Research Network, MedStar Washington Hospital Center, Washington, DC, USA
| | | |
Collapse
|
3
|
Ultrathin Struts Drug-Eluting Stents: A State-of-the-Art Review. J Pers Med 2022; 12:jpm12091378. [PMID: 36143162 PMCID: PMC9503315 DOI: 10.3390/jpm12091378] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Revised: 08/21/2022] [Accepted: 08/23/2022] [Indexed: 11/17/2022] Open
Abstract
New-generation drug-eluting stents (DESs) represent the standard of care for patients undergoing percutaneous coronary intervention (PCI). Recent iterations in DES technology have led to the development of newer stent platforms with a further reduction in strut thickness. This new DES class, known as ultrathin struts DESs, has struts thinner than 70 µm. The evidence base for these devices consists of observational data, large-scale meta-analyses, and randomized trials with long-term follow-up, which have been conducted to investigate the difference between ultrathin struts DESs and conventional new-generation DESs in a variety of clinical settings and lesion subsets. Ultrathin struts DESs may further improve the efficacy and safety profile of PCI by reducing the risk of target-lesion and target-vessel failures in comparison to new-generation DESs. In this article, we reviewed device characteristics and clinical data of the Orsiro (Biotronik, Bülach, Switzerland), Coroflex ISAR (B. Braun Melsungen, Germany), BioMime (Meril Life Sciences Pvt. Ltd., Gujarat, India), MiStent (MiCell Technologies, USA), and Supraflex (Sahajanand Medical Technologies, Surat, India) sirolimus-eluting stents.
Collapse
|
4
|
Giacaman A, Assef V, Ramirez P, Puentes Á, Perez O, Olmos A, Perez L, Venegas R, Pincetti C, Vergara MJ, Antezana G, Cavada G, García-García HM, Maluenda G. PRospective Observational Registry Evaluating the Safety and Effectivenessof Orsiro Stent in Chilean Patients - ROSES Registry. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2022; 36:65-70. [PMID: 34092499 DOI: 10.1016/j.carrev.2021.05.022] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2021] [Revised: 05/18/2021] [Accepted: 05/24/2021] [Indexed: 11/15/2022]
Abstract
BACKGROUND There is little information on the performance of the new generation of stents with bioabsorbable polymers in the Latin American population. This registry aimed to further validate the safety and efficacy of the Orsiro bioresorbable-polymer sirolimus-eluting stent (BPSES) in unselected patients undergoing percutaneous coronary intervention (PCI) in Chilean centers. METHODS We prospectively enrolled patients undergoing PCI with BPSES in 6 Chilean centers. The primary endpoint was defined as the composite of cardiac death, target vessel-related myocardial infarction (MI), and clinically driven target lesion revascularization at 1-year follow-up. RESULTS From April 2017 to February 2019, 520 patients were enrolled in the registry, more frequently male (74.6%), with a mean age of 62.7 ± 10.8 years and a high prevalence of diabetes (40.2%). The clinical presentation was stable angina in 41.1% (n = 214), acute MI in 52.5% (n = 167 [32.1%] ST-elevation MI and n = 106 [20.4%] non-ST-elevation MI), and unstable angina in 6.3% (n = 33). Of 610 treated lesions, 425 (69.7%) were American College of Cardiology/American Heart Association type B or C lesions. Device and procedural success were achieved in 99.4% and 98.7% of the patients, respectively. The primary endpoint of the study occurred in 4%, primarily driven by cardiac death. CONCLUSIONS The results of the ROSES multicenter registry indicated good clinical outcomes of BPSES Orsiro in all-comers Latin Americann patients undergoing PCI, despite the high-risk patients and treated lesions.
Collapse
Affiliation(s)
- Arturo Giacaman
- San Borja Arriarán Hospital & University of Chile, Santiago, Chile
| | - Víctor Assef
- Puerto Montt Regional Hospital, Puerto Montt, Chile
| | | | | | | | | | - Luis Perez
- Guillermo Grant Benavente Hospital & University of Concepción, Concepción, Chile
| | - Reinaldo Venegas
- Guillermo Grant Benavente Hospital & University of Concepción, Concepción, Chile
| | | | | | - Gonzalo Antezana
- San Borja Arriarán Hospital & University of Chile, Santiago, Chile
| | - Gabriel Cavada
- San Borja Arriarán Hospital & University of Chile, Santiago, Chile
| | | | - Gabriel Maluenda
- San Borja Arriarán Hospital & University of Chile, Santiago, Chile.
| |
Collapse
|
5
|
Pilgrim T, Rothenbühler M, Siontis GC, Kandzari DE, Iglesias JF, Asami M, Lefèvre T, Piccolo R, Koolen J, Saito S, Slagboom T, Muller O, Waksman R, Windecker S. Biodegradable polymer sirolimus-eluting stents vs durable polymer everolimus-eluting stents in patients undergoing percutaneous coronary intervention: A meta-analysis of individual patient data from 5 randomized trials. Am Heart J 2021; 235:140-148. [PMID: 33609498 DOI: 10.1016/j.ahj.2021.02.009] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/18/2020] [Accepted: 02/06/2021] [Indexed: 11/29/2022]
Abstract
BACKGROUND Newest generation drug-eluting stents combine biodegradable polymers with ultrathin stent platforms in order to minimize vessel injury and inflammatory response. Evidence from randomized controlled trials suggested that differences in stent design translate into differences in clinical outcome. The aim of the present study was to evaluate the safety and efficacy of ultrathin strut, biodegradable polymer sirolimus eluting stents (BP SES) compared with thin strut, durable polymer everolimus-eluting stents (DP EES) among patients undergoing percutaneous coronary intervention (PCI). METHODS We pooled individual participant data from 5 randomized trials (NCT01356888, NCT01939249, NCT02389946, NCT01443104, NCT02579031) including a total of 5,780 patients, and performed a one-stage meta-analysis using a mixed effects Cox regression model. RESULTS At a median duration of follow-up of 739 days (interquartile range 365-1,806 days), target-lesion failure occurred in 337 (10.3%) and 304 (12.2%) patients treated with BP SES and DP EES (HR 0.86, 95%CI 0.71-1.06, P = .16). There were no significant differences between BP SES and DP EES with regards to cardiac death (111 (3.4%) vs 102 (4.1%); HR 1.05, 95%CI 0.80-1.37, P = .73), target-vessel myocardial infarction (136 (4.1%) vs 126 (5.0%), HR 0.79, 95%CI 0.62-1.01, P = .061), and clinically-driven target-lesion revascularization (163 (5.0%) vs 147 (5.9%); HR 0.94, 95%CI 0.75-1.18, P = .61). The effect was consistent across major subgroups. In a landmark analysis, there was no significant interaction between treatment effect and timing of events. CONCLUSIONS In this patient-level meta-analysis of 5 randomized controlled trials, BP SES were associated with a similar risk of target-lesion failure compared with DP EES among patients undergoing PCI. STUDY REGISTRATION PROSPERO registry (CRD42018109098).
Collapse
Affiliation(s)
- Thomas Pilgrim
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
| | - Martina Rothenbühler
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - George Cm Siontis
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | | | - Juan F Iglesias
- Division of Cardiology, Geneva University Hospitals, Geneva, Switzerland
| | - Masahiko Asami
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Thierry Lefèvre
- Department of Interventional Cardiology, Hopital Jacques Cartier, Massy, France
| | - Raffaele Piccolo
- Division of Cardiology, Department of Advanced Biomedical Sciences, Federico II University, Naples, Italy
| | | | - Shigeru Saito
- Division of Cardiology & Catheterization Laboratories, Shonan Kamakura General Hospital, Japan; Sapporo Higashi Tokushukai Hospital, Sapporo, Japan
| | | | - Olivier Muller
- Department of Cardiology, Lausanne University Hospital, Lausanne, Switzerland
| | - Ron Waksman
- Division of Interventional Cardiology, MedStar Cardiovascular Research Network, MedStar Washington Hospital Center, Washington, DC
| | - Stephan Windecker
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| |
Collapse
|
6
|
Ultrathin Bioresorbable-Polymer Sirolimus-Eluting Stents Versus Thin Durable-Polymer Everolimus-Eluting Stents for Coronary Revascularization. JACC Cardiovasc Interv 2020; 13:1343-1353. [DOI: 10.1016/j.jcin.2020.02.019] [Citation(s) in RCA: 43] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2019] [Revised: 02/06/2020] [Accepted: 02/19/2020] [Indexed: 11/24/2022]
|
7
|
Complete 2-Year Results Confirm Bayesian Analysis of the SURTAVI Trial. JACC Cardiovasc Interv 2020; 13:323-331. [DOI: 10.1016/j.jcin.2019.10.043] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/09/2019] [Revised: 09/17/2019] [Accepted: 10/09/2019] [Indexed: 01/01/2023]
|
8
|
The Orsiro Ultrathin, Bioresorbable-Polymer Sirolimus-Eluting Stent: A Review of Current Evidence. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2020; 21:540-548. [PMID: 31952919 DOI: 10.1016/j.carrev.2019.12.039] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2019] [Revised: 12/19/2019] [Accepted: 12/30/2019] [Indexed: 11/23/2022]
Abstract
Advances in stent design and the development of bioresorbable polymers have allowed the development of novel stent technologies such as the Orsiro bioresorbable-polymer sirolimus eluting stent (BP-SES). Over several noninferiority trials, the BP-SES has demonstrated itself to be a safe and effective therapy for obstructive coronary artery disease. This article reviews the current evidence of the efficacy of the BP-SES and examines its performance in high-risk populations, such as patients presenting with ST-segment myocardial infarction, chronic total occlusions, diabetes, and small vessel disease.
Collapse
|
9
|
Health Economic Evaluation of an Ultrathin, Bioresorbable-Polymer Sirolimus-Eluting Coronary Stent Compared to a Thin, Durable-Polymer Everolimus-Eluting Stent. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2019; 20:752-757. [DOI: 10.1016/j.carrev.2018.11.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2018] [Revised: 10/22/2018] [Accepted: 11/06/2018] [Indexed: 11/19/2022]
|
10
|
Kobo O, Roguin A. Orsiro: ultrathin bioabsorbable polymer sirolimus-eluting stent. Future Cardiol 2019; 15:295-300. [DOI: 10.2217/fca-2019-0001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Recent stent developments aimed to reduce and eliminate the long-term inflammatory response include thinner struts, modifications to stent design and the development of bioresorbable polymers (BP). We aimed to summarize the main findings and to discuss the established and the potential benefits of the Orsiro BP sirolimus-eluting stents in everyday clinical use. We have reviewed the available evidence on the clinical performance of the Orsiro BP drug-eluting stents. Orsiro BP sirolimus-eluting stents is clinically proven and showed noninferiority against major drug-eluting stents and provides high safety and efficacy profile at long-term follow-up. Furthermore, it may be the preferred treatment option in specific subgroups as acute coronary syndrome, as shown in the BIOFLOW V trial.
Collapse
Affiliation(s)
- Ofer Kobo
- Hillel Yaffe Medical Center, Hadera, Faculty of Medicine – Technion Israel Institute of Technology, Israel
| | - Ariel Roguin
- Hillel Yaffe Medical Center, Hadera, Faculty of Medicine – Technion Israel Institute of Technology, Israel
| |
Collapse
|
11
|
Roskoski R. Properties of FDA-approved small molecule protein kinase inhibitors. Pharmacol Res 2019; 144:19-50. [DOI: 10.1016/j.phrs.2019.03.006] [Citation(s) in RCA: 290] [Impact Index Per Article: 58.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2019] [Accepted: 03/07/2019] [Indexed: 12/14/2022]
|
12
|
Kandzari DE, Koolen JJ, Doros G, Massaro JJ, Garcia-Garcia HM, Bennett J, Roguin A, Gharib EG, Cutlip DE, Waksman R. Ultrathin Bioresorbable Polymer Sirolimus-Eluting Stents Versus Thin Durable Polymer Everolimus-Eluting Stents. J Am Coll Cardiol 2018; 72:3287-3297. [DOI: 10.1016/j.jacc.2018.09.019] [Citation(s) in RCA: 54] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/09/2018] [Revised: 09/18/2018] [Accepted: 09/18/2018] [Indexed: 10/28/2022]
|
13
|
Cassese S, Lahmann AL, Joner M. Ultrathin strut biodegradable-polymer sirolimus-eluting stents: being wary or going with the flow? J Thorac Dis 2018; 10:688-692. [PMID: 29607135 DOI: 10.21037/jtd.2018.01.118] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Salvatore Cassese
- Deutsches Herzzentrum München, Technische Universität München, Munich, Germany
| | - Anna Lena Lahmann
- Deutsches Herzzentrum München, Technische Universität München, Munich, Germany
| | - Michael Joner
- Deutsches Herzzentrum München, Technische Universität München, Munich, Germany.,DZHK (German Centre for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich, Germany
| |
Collapse
|