Farenden S, Chung Y, Cui A, Ferguson I. Prospective, observational study investigating the level of agreement between transcutaneous and invasive carbon dioxide measurements in critically ill emergency department patients. Emerg Med J 2023; 40:646-650. [PMID: 37479485 DOI: 10.1136/emermed-2022-212465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Accepted: 06/16/2023] [Indexed: 07/23/2023]
Abstract
BACKGROUND Transcutaneous carbon dioxide (Ptcco2) measurement is a non-invasive surrogate marker for arterial carbon dioxide (Paco2), which requires invasive arterial blood sampling. Use of Ptcco2 has been examined in different clinical settings, however, most existing evidence in the adult emergency department (ED) setting shows insufficient agreement between the measurements. This study assessed the level of agreement between Ptcco2 and Paco2 in undifferentiated adult ED patients across multiple timepoints. METHODS This prospective observational study (study period 2020-2021) assessed paired Ptcco2 and Paco2 measurements at four consecutive timepoints (0, 30, 60 and 90 min) in adult (aged 18 years or over) Australian ED patients requiring hospital admission and arterial catheter insertion. Agreement between the pairs was assessed using Bland-Altman analysis. It was prospectively determined by expert consensus that limits of ±4 mm Hg would be a clinically acceptable level of agreement between Ptcco2 and Paco2. RESULTS During the study period 168 paired Ptcco2 and Paco2 readings were taken from 42 adult ED patients. Bland-Altman analysis showed a mean Ptcco2 reading 3.85 mm Hg higher than Paco2, although at each timepoint the 95% CIs breached the limit of 4 mm Hg difference. In addition, only 66% (111/168) of results fell within the clinically acceptable range. CONCLUSION The level of agreement between Ptcco2 and Paco2 measurements may not be sufficiently precise for the adoption of Ptcco2 monitoring in patients presenting to the ED.
Collapse
Affiliation(s)
- Scott Farenden
- Emergency Department, Liverpool Hospital, Liverpool, New South Wales, Australia
| | - Yewon Chung
- Department of Respiratory and Sleep Medicine, Liverpool Hospital, Liverpool, New South Wales, Australia
- South Western Sydney Clinical School, University of New South Wales, Sydney, New South Wales, Australia
| | - Amy Cui
- Emergency Department, Liverpool Hospital, Liverpool, New South Wales, Australia
| | - Ian Ferguson
- Emergency Department, Liverpool Hospital, Liverpool, New South Wales, Australia
- Ambulance Service of NSW, Rozelle, New South Wales, Australia
| |
Collapse
|
2
|
Yang SC, Lee CW. Physiological effects of N95 respirators on rescuers during cardiopulmonary resuscitation. Heliyon 2023; 9:e18970. [PMID: 37600379 PMCID: PMC10432712 DOI: 10.1016/j.heliyon.2023.e18970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Revised: 07/14/2023] [Accepted: 08/03/2023] [Indexed: 08/22/2023] Open
Abstract
Objectives There is a lack of evidence in the medical literature reporting the physiological stress imposed by the wearing of N95 respirators during cardiopulmonary resuscitation (CPR) in healthcare providers. The aim of this study is to monitor the changes in hemodynamics and blood gas profiles in rescuers during the performance of CPR while wearing N95 respirators. Methods Thirty-two healthy healthcare workers performed standard CPR on manikins, each participant conducted 2 min of chest compression followed by 2 min of rest for 3 cycles. A non-invasive blood gas measuring device via a fingertip detector was used to collect arterial blood gas and hemodynamic data. Student t-test was used for comparison of various physiologic parameters before and after each session of chest compression. Results There were no significant differences in arterial blood gas profiles including partial pressure of arterial carbon dioxide and partial pressure of arterial oxygen before and after each session of chest compression (p > 0.05 for all). Heart rate and cardiac output were significantly higher after CPR (p < 0.05 for all), but no significant changes were found on blood pressure. Conclusions Our data suggest that healthcare providers wearing N95 respirators during provision of CPR in a short period of time does not cause any significant abnormalities in blood gas profiles and blood pressure. This may provide evidence to reassure the safe use of N95 respirator during performance of CPR.
Collapse
Affiliation(s)
- Shih-Chia Yang
- Department of Emergency Medicine, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Chi-Wei Lee
- Institute of Medical Science and Technology, National Sun Yat-Sen University, Kaohsiung, Taiwan
| |
Collapse
|
3
|
Umeda A, Ishizaka M, Ikeda A, Miyagawa K, Mochida A, Takeda H, Takeda K, Fukushi I, Okada Y, Gozal D. Recent Insights into the Measurement of Carbon Dioxide Concentrations for Clinical Practice in Respiratory Medicine. SENSORS (BASEL, SWITZERLAND) 2021; 21:5636. [PMID: 34451079 PMCID: PMC8402333 DOI: 10.3390/s21165636] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/26/2021] [Revised: 08/06/2021] [Accepted: 08/16/2021] [Indexed: 12/28/2022]
Abstract
In the field of respiratory clinical practice, the importance of measuring carbon dioxide (CO2) concentrations cannot be overemphasized. Within the body, assessment of the arterial partial pressure of CO2 (PaCO2) has been the gold standard for many decades. Non-invasive assessments are usually predicated on the measurement of CO2 concentrations in the air, usually using an infrared analyzer, and these data are clearly important regarding climate changes as well as regulations of air quality in buildings to ascertain adequate ventilation. Measurements of CO2 production with oxygen consumption yield important indices such as the respiratory quotient and estimates of energy expenditure, which may be used for further investigation in the various fields of metabolism, obesity, sleep disorders, and lifestyle-related issues. Measures of PaCO2 are nowadays performed using the Severinghaus electrode in arterial blood or in arterialized capillary blood, while the same electrode system has been modified to enable relatively accurate non-invasive monitoring of the transcutaneous partial pressure of CO2 (PtcCO2). PtcCO2 monitoring during sleep can be helpful for evaluating sleep apnea syndrome, particularly in children. End-tidal PCO2 is inferior to PtcCO2 as far as accuracy, but it provides breath-by-breath estimates of respiratory gas exchange, while PtcCO2 reflects temporal trends in alveolar ventilation. The frequency of monitoring end-tidal PCO2 has markedly increased in light of its multiple applications (e.g., verify endotracheal intubation, anesthesia or mechanical ventilation, exercise testing, respiratory patterning during sleep, etc.).
Collapse
Affiliation(s)
- Akira Umeda
- Department of General Medicine, School of Medicine, IUHW Shioya Hospital, International University of Health and Welfare (IUHW), Yaita 329-2145, Japan
| | - Masahiro Ishizaka
- Department of Physical Therapy, School of Health Science, International University of Health and Welfare, Otawara 324-8501, Japan
| | - Akane Ikeda
- Department of Rehabilitation, IUHW Shioya Hospital, International University of Health and Welfare (IUHW), Yaita 329-2145, Japan
| | - Kazuya Miyagawa
- Department of Pharmacology, School of Pharmacy, International University of Health and Welfare, Otawara 324-8501, Japan
| | - Atsumi Mochida
- Department of Pharmacology, School of Pharmacy, International University of Health and Welfare, Otawara 324-8501, Japan
| | - Hiroshi Takeda
- Department of Pharmacology, School of Pharmacy, International University of Health and Welfare, Otawara 324-8501, Japan
- Department of Pharmacology, School of Pharmacy at Fukuoka, International University of Health and Welfare, Okawa 831-8501, Japan
| | - Kotaro Takeda
- Faculty of Rehabilitation, School of Healthcare, Fujita Health University, Toyoake 470-1192, Japan
| | - Isato Fukushi
- Faculty of Health Sciences, Uekusa Gakuen University, Chiba 264-0007, Japan
- Laboratory of Electrophysiology, Clinical Research Center, Murayama Medical Center, Musashimurayama 208-0011, Japan
| | - Yasumasa Okada
- Laboratory of Electrophysiology, Clinical Research Center, Murayama Medical Center, Musashimurayama 208-0011, Japan
| | - David Gozal
- Department of Child Health and the Child Health Research Institute, MU Women's and Children's Hospital, University of Missouri, Columbia, MO 65201, USA
| |
Collapse
|
4
|
Barneck M, Papa L, Cozart A, Lentine K, Ladde J, Nguyen L, Mayfield J, Thundiyil J. The utility of transcutaneous carbon dioxide measurements in the emergency department: A prospective cohort study. J Am Coll Emerg Physicians Open 2021; 2:e12513. [PMID: 34296208 PMCID: PMC8286116 DOI: 10.1002/emp2.12513] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Revised: 06/23/2021] [Accepted: 06/25/2021] [Indexed: 11/08/2022] Open
Abstract
BACKGROUND Rapid identification of patients with occult injury and illness in the emergency department can be difficult. Transcutaneous carbon dioxide (TCO2) and oxygen (TO2) measurements may be non-invasive surrogate markers for the identification of such patients. OBJECTIVES To determine if TCO2 or TO2 are useful adjuncts for identifying severe illness and the correlation between TCO2, lactate, and end tidal carbon dioxide (ETCO2). METHODS Prospective TCO2 and TO2 measurements at a tertiary level 1 trauma center were obtained using a transcutaneous sensor on 300 adult patients. Severe illness was defined as death, intensive care unit (ICU) admission, bilevel positive airway pressure, vasopressor use, or length of stay >2 days. TCO2 and TO2 were compared to illness severity using t tests and correlation coefficients. RESULTS Mean TO2 did not differ between severe illness (58.9, 95% CI 54.9-62.9) and non-severe illness (58.0, 95% CI 54.7-61.1). Mean TCO2 was similar between severe (34.6, 95% CI 33-36.2) vs non-severe illness (35.9, 95% CI 34.7-37.1). TCO2 was 28.7 (95% CI 24.0-33.4) for ICU vs. 35.9 (95% CI 34.9-36.9) for non-ICU patients. The mean TCO2 in those with lactate > 2.0 was 29.8 (95% CI 25.8-33.8) compared with 35.7 (95% CI 34.9-36.9) for lactate < 2.0. TCO2 was not correlated with ETCO2 (r = 0.32, 95% CI 0.22-0.42). CONCLUSION TCO2 could be a useful adjunct for identifying significant injury and illness and patient outcomes in an emergency department (ED) population. TO2 did not predict severe illness. TCO2 and ETCO2 are only moderately correlated, indicating that they are not equivalent and may be useful under different circumstances.
Collapse
Affiliation(s)
| | - Linda Papa
- Department of Emergency MedicineOrlando HealthOrlandoFloridaUSA
| | - Ashley Cozart
- College of MedicineUniversity of Central FloridaOrlandoFloridaUSA
| | - Kain Lentine
- College of MedicineUniversity of Central FloridaOrlandoFloridaUSA
| | - Jay Ladde
- Department of Emergency MedicineOrlando HealthOrlandoFloridaUSA
| | - Linh Nguyen
- College of MedicineFlorida State UniversityTallahasseeFloridaUSA
| | - Jeremy Mayfield
- College of MedicineUniversity of Central FloridaOrlandoFloridaUSA
| | - Josef Thundiyil
- Department of Emergency MedicineOrlando HealthOrlandoFloridaUSA
| |
Collapse
|
5
|
Carlson CS, Brown SR, Wilson MW, Choi PJ. Noninvasive ventilation: An important option in the management of hemidiaphragm paralysis. J Card Surg 2021; 36:3921-3923. [PMID: 34260766 DOI: 10.1111/jocs.15824] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Accepted: 06/30/2021] [Indexed: 11/27/2022]
Abstract
Hemidiaphragm paralysis (HP) is a potential complication of cardiac surgery. While most patients are either asymptomatic or have mild symptoms, some are at risk of developing life-threatening hypercapnia. We present a case of a patient who developed HP after tricuspid valve replacement. Diaphragm plication was deferred due to underlying comorbidities, but over time she developed severe hypercapnic respiratory failure requiring intensive care unit admission. Chronic noninvasive ventilation therapy (NIV) was initiated, which improved her symptoms and hypercapnia and prevented further hospitalizations. For patients with iatrogenic HP unable to undergo diaphragm plication, Pulmonology referral for initiation of NIV should be strongly considered.
Collapse
Affiliation(s)
- Christie S Carlson
- Division of Pulmonary and Critical Care Medicine, University of Michigan, Ann Arbor, Michigan, USA
| | - Sarah R Brown
- Division of Pulmonary and Critical Care Medicine, University of Michigan, Ann Arbor, Michigan, USA
| | - Matthew W Wilson
- Division of Pulmonary and Critical Care Medicine, University of Michigan, Ann Arbor, Michigan, USA
| | - Philip J Choi
- Division of Pulmonary and Critical Care Medicine, University of Michigan, Ann Arbor, Michigan, USA
| |
Collapse
|
6
|
Dicembrino M, Alejandra Barbieri I, Pereyra C, Leske V. End-tidal CO 2 and transcutaneous CO 2 : Are we ready to replace arterial CO 2 in awake children? Pediatr Pulmonol 2021; 56:486-494. [PMID: 33382537 DOI: 10.1002/ppul.25217] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/22/2020] [Revised: 11/27/2020] [Accepted: 11/30/2020] [Indexed: 11/08/2022]
Abstract
INTRODUCTION Arterial blood gas analysis (ABG) is the gold standard test for carbon dioxide measurement. End-tidal PCO2 (PetCO2 ) and transcutaneous PCO2 (PtcCO2 ) are noninvasive alternative methods. OBJECTIVE To examine the use of PetCO2 and PtcCO2 as PaCO2 surrogates in awake children. METHODS A prospective observational study. Consecutive awake children in a stable condition referred to the Sleep Unit of Hospital de Pediatría Dr. J. P. Garrahan with suspected or confirmed sleep-related respiratory disorders requiring ABG were included. PetCO2 and PtcCO2 were recorded simultaneously during arterial puncture. PetCO2 and PtCO2 values were compared with PaCO2 . Correlation coefficient and Bland-Altman analysis were applied. The sample size was calculated considering a mean difference ≤3 mmHg as clinically acceptable. RESULTS Sixty-eight sample sets were obtained from 67 patients. The median age was 9.11 years (0.23-18.76). During 94.1% of the procedures patients breathed spontaneously, 30% needed multiple punctures and 92% resulted in pain. Median (IQR) PaCO2 (mmHg) was 36.3 (31.45; 40.90), PetCO2 33.0 (29; 39) and PtcCO2 38.8 (32.95; 43.32). Correlation and agreement for PaCO2 /PetCO2 and PaCO2 /PtcCO2 was r = .6 and .9, and media of bias = 2.83 (-9.97; 15.64) and -1.88 (-9.01; 5.24), respectively. Hypercapnia (PaCO2 > 45.0 mmHg) was present in 8/68 (11.8%) samples. Sensitivity, specificity, positive predictive value and negative predictive value to detect hypercapnia with PetCO2 was 38%, 98%, 75%, and 92%, respectively, and with PtcCO2 , 100%, 90%, 57%, and 100%, respectively. CONCLUSION PtcCO2 showed better agreement with PaCO2 than PetCO2 but because of the wide dispersion of values, neither method can replace the gold standard. Transcutaneous CO2 might be a good screening tool to detect hypercapnia in awake children.
Collapse
Affiliation(s)
- Manuela Dicembrino
- Sleep Unit, Pulmonology Department, Hospital de Pediatría Prof. Dr. J. P. Garrahan, Buenos Aires, Argentina
| | | | - Carla Pereyra
- Pediatrics Department, Hospital Italiano de Buenos Aires, Buenos Aires, Argentina
| | - Vivian Leske
- Sleep Unit, Pulmonology Department, Hospital de Pediatría Prof. Dr. J. P. Garrahan, Buenos Aires, Argentina
| |
Collapse
|
7
|
Umeda A, Ishizaka M, Tasaki M, Yamane T, Watanabe T, Inoue Y, Mochizuki T, Okada Y, Kesler S. Evaluation of time courses of agreement between minutely obtained transcutaneous blood gas data and the gold standard arterial data from spontaneously breathing Asian adults, and various subgroup analyses. BMC Pulm Med 2020; 20:151. [PMID: 32471394 PMCID: PMC7257137 DOI: 10.1186/s12890-020-01184-w] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2018] [Accepted: 05/13/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Usual clinical practice for arterial blood gas analysis (BGA) in conscious patients involves a one-time arterial puncture to be performed after a resting period of 20-30 min. The aim of this study was to evaluate the use of transcutaneous BGA for estimating this gold standard arterial BGA. METHODS Spontaneously breathing Asian adults (healthy volunteers and respiratory patients) were enrolled (n = 295). Transcutaneous PO2 (PtcO2) and PCO2 (PtcCO2) were monitored using a transcutaneous monitor (TCM4, Radiometer Medical AsP, Denmark) with sensors placed on the chest, forearm, earlobe or forehead. Transcutaneous BGA at 1-min intervals was compared with arterial BGA at 30 min. Reasonable steps to find severe hypercapnia with PaCO2 > 50 mmHg were evaluated. RESULTS Sensors on the chest and forearm were equally preferred and used because of small biases (n = 272). The average PCO2 bias was close to 0 mmHg at 4 min, and was almost constant (4-5 mmHg) with PtcCO2 being higher than PaCO2 at ≥8 min. The limit of agreement for PCO2 narrowed over time: ± 13.6 mmHg at 4 min, ± 7.5 mmHg at 12-13 min, and ± 6.3 mmHg at 30 min. The limit of agreement for PO2 also narrowed over time (± 23.1 mmHg at 30 min). Subgroup analyses showed that the PaCO2 and PaO2 levels, gender, and younger age significantly affected the biases. All hypercapnia subjects with PaCO2 > 50 mmHg (n = 13) showed PtcCO2 ≥ 50 mmHg for until 12 min. CONCLUSIONS Although PtcCO2 is useful, it cannot completely replace PaCO2 because PCO2 occasionally showed large bias. On the other hand, the prediction of PaO2 using PtcO2 was unrealistic in Asian adults. PtcCO2 ≥ 50 mmHg for until 12 min can be used as a screening tool for severe hypercapnia with PaCO2 > 50 mmHg.
Collapse
Affiliation(s)
- Akira Umeda
- Departments of Internal Medicine, International University of Health and Welfare (IUHW) Shioya Hospital, Tomita 77, Yaita-City, Tochigi, 329-2145, Japan.
| | - Masahiro Ishizaka
- Departments of Rehabilitation, International University of Health and Welfare (IUHW) Shioya Hospital, Yaita-City, Japan
| | - Masamichi Tasaki
- Departments of Rehabilitation, International University of Health and Welfare (IUHW) Shioya Hospital, Yaita-City, Japan
| | - Tateki Yamane
- Departments of Internal Medicine, International University of Health and Welfare (IUHW) Shioya Hospital, Tomita 77, Yaita-City, Tochigi, 329-2145, Japan
| | - Taiji Watanabe
- Departments of Internal Medicine, International University of Health and Welfare (IUHW) Shioya Hospital, Tomita 77, Yaita-City, Tochigi, 329-2145, Japan
| | - Yasushi Inoue
- Departments of Internal Medicine, International University of Health and Welfare (IUHW) Shioya Hospital, Tomita 77, Yaita-City, Tochigi, 329-2145, Japan
| | - Taichi Mochizuki
- Departments of Internal Medicine, International University of Health and Welfare (IUHW) Shioya Hospital, Tomita 77, Yaita-City, Tochigi, 329-2145, Japan
| | - Yasumasa Okada
- Department of Internal Medicine, National Hospital Organization Murayama Medical Center, Musashimurayama-City, Japan
| | - Sarah Kesler
- Intensive Care Unit, University of Minnesota, Minneapolis, MN, USA
| |
Collapse
|
8
|
Mari A, Nougue H, Mateo J, Vallet B, Vallée F. Transcutaneous PCO 2 monitoring in critically ill patients: update and perspectives. J Thorac Dis 2019; 11:S1558-S1567. [PMID: 31388461 DOI: 10.21037/jtd.2019.04.64] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
The physiology of venous and tissue CO2 monitoring has a long and well-established physiological background, leading to the technological development of different tissue capnometric devices, such as transcutaneous capnometry monitoring (TCM). To outline briefly, measuring transcutaneous PCO2 (tcPCO2) depends on at least three main phenomena: (I) the production of CO2 by tissues (VCO2), (II) the removal of CO2 from the tissues by perfusion (wash-out phenomenon), and (III) the reference value of CO2 at tissue inlet represented by arterial CO2 content (approximated by arterial PCO2, or artPCO2). For this reason, there are, at present, roughly two clinical uses for tcPCO2 measurement: a respiratory approach where tcPCO2 is likely to estimate and non-invasively track artPCO2; and a hemodynamic under-estimate use where tcPCO2 can reflect tissue perfusion, summarized by a so-called "tc-art PCO2 gap". Recent research shows that these two uses are not incompatible and could be combined. The spectrum of indications and validation studies in ICUs is summarized in this review to give a survey of the potential applications of TCM in critically ill patients, focusing mainly on its potential (micro)circulatory monitoring contribution. We strongly believe that the greatest benefit of measuring tcPCO2 is not to only to estimate artPCO2, but also to quantify the gap between these two values, which can then help clinicians continuously and noninvasively assess both respiratory and hemodynamic failures in critically ill patients.
Collapse
Affiliation(s)
- Arnaud Mari
- Intensive Care Unit, Hôpital Yves Le Foll, Saint-Brieuc, France
| | - Hélène Nougue
- Department of Anesthesiology and Critical Care, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris (AP-HP), Paris, France.,UMR-S942, Hôpital Lariboisière, Paris, France.,University of Paris Diderot, Paris, France
| | - Joaquim Mateo
- Department of Anesthesiology and Critical Care, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris (AP-HP), Paris, France.,UMR-S942, Hôpital Lariboisière, Paris, France.,University of Paris Diderot, Paris, France
| | | | - Fabrice Vallée
- Department of Anesthesiology and Critical Care, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris (AP-HP), Paris, France.,UMR-S942, Hôpital Lariboisière, Paris, France.,University of Paris Diderot, Paris, France.,MEDISIM, Inria Paris-Saclay, Palaiseau, France
| |
Collapse
|
9
|
Estimating Arterial Partial Pressure of Carbon Dioxide in Ventilated Patients: How Valid Are Surrogate Measures? Ann Am Thorac Soc 2018; 14:1005-1014. [PMID: 28570147 DOI: 10.1513/annalsats.201701-034fr] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
The arterial partial pressure of carbon dioxide (PaCO2) is an important parameter in critically ill, mechanically ventilated patients. To limit invasive procedures or for more continuous monitoring of PaCO2, clinicians often rely on venous blood gases, capnography, or transcutaneous monitoring. Each of these has advantages and limitations. Central venous Pco2 allows accurate estimation of PaCO2, differing from it by an amount described by the Fick principle. As long as cardiac output is relatively normal, central venous Pco2 exceeds the arterial value by approximately 4 mm Hg. In contrast, peripheral venous Pco2 is a poor predictor of PaCO2, and we do not recommend using peripheral venous Pco2 in this manner. Capnography offers measurement of the end-tidal Pco2 (PetCO2), a value that is close to PaCO2 when the lung is healthy. It has the advantage of being noninvasive and continuously available. In mechanically ventilated patients with lung disease, however, PetCO2 often differs from PaCO2, sometimes by a large degree, often seriously underestimating the arterial value. Dependence of PetCO2 on alveolar dead space and ventilator expiratory time limits its value to predict PaCO2. When lung function or ventilator settings change, PetCO2 and PaCO2 can vary in different directions, producing further uncertainty. Transcutaneous Pco2 measurement has become practical and reliable. It is promising for judging steady state values for PaCO2 unless there is overt vasoconstriction of the skin. Moreover, it can be useful in conditions where capnography fails (high-frequency ventilation) or where arterial blood gas analysis is burdensome (clinic or home management of mechanical ventilation).
Collapse
|
10
|
Bauchat JR, McCarthy R, Fitzgerald P, Kolb S, Wong CA. Transcutaneous Carbon Dioxide Measurements in Women Receiving Intrathecal Morphine for Cesarean Delivery: A Prospective Observational Study. Anesth Analg 2017; 124:872-878. [PMID: 28099291 DOI: 10.1213/ane.0000000000001751] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
BACKGROUND Neuraxial morphine is the most commonly used analgesic technique after cesarean delivery. The incidence of respiratory depression is reported to be very low (0%-1.2%) in this patient population as measured by pulse oximetry and respiratory rates. However, hypercapnia may be a more sensitive measure of respiratory depression. In the current study, the incidence of hypercapnia events (transcutaneous CO2 [TcCO2] >50 mm Hg) for ≥2-minute duration was evaluated using the Topological Oscillation Search with Kinematical Analysis monitor in women who received intrathecal morphine for postcesarean delivery analgesia. METHODS Healthy women (>37 weeks of gestation) scheduled for a cesarean delivery with spinal anesthesia with intrathecal morphine were recruited. Baseline STOP-BANG sleep apnea questionnaire and TcCO2 readings were obtained. Spinal anesthesia was initiated with 12 mg hyperbaric bupivacaine, 15 µg fentanyl, and 150 µg morphine. The Topological Oscillation Search with Kinematical Analysis monitor was reapplied in the postanesthesia care unit and TcCO2 measurements obtained for up to 24 hours. Supplemental opioid administration and adverse respiratory events were recorded. The primary outcome was the incidence of hypercapnia events, defined as a TcCO2 reading >50 mm Hg for ≥2 minutes in the first 24 hours after delivery. RESULTS Of the 120 women who were recruited, 108 completed the study. Thirty-five women (32%; 99.15% confidence interval, 21%-45%) reached the primary outcome of a sustained hypercapnia event. The median time (interquartile range [IQR]) from intrathecal morphine administration to the hypercapnia event was 300 (124-691) minutes. The median (IQR) number of events was 3 (1-6) and longest duration of an event was 25.6 (8.4-98.7) minutes. Baseline median (IQR) TcCO2 measurements were 35 (30-0) mm Hg and postoperatively, median (IQR) TcCO2 measurements were 40 (36-43) mm Hg, a difference of 5 mm Hg (99.15% confidence interval of the difference 2-8 mm Hg, P < .001). The incidence of hypercapnia events was 5.4% in women with a baseline TcCO2 value ≤31 mm Hg, 22.5% with a baseline TcCO2 between 32 and 38 mm Hg, and 77.4% with a baseline TcCO2 >38 mm Hg (P < .001). CONCLUSIONS Hypercapnia events (>50 mm Hg for ≥2-minute duration) occurred frequently in women receiving 150 μg intrathecal morphine for postcesarean analgesia. Higher baseline TcCO2 readings were observed in women who had hypercapnia events.
Collapse
Affiliation(s)
- Jeanette R Bauchat
- From the *Department of Anesthesiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois; and †Department of Anesthesia, University of Iowa Carver College of Medicine, Iowa City, Iowa
| | | | | | | | | |
Collapse
|
11
|
Validity of transcutaneous PCO 2 in monitoring chronic hypoventilation treated with non-invasive ventilation. Respir Med 2016; 112:112-8. [DOI: 10.1016/j.rmed.2016.01.017] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/14/2015] [Revised: 01/21/2016] [Accepted: 01/23/2016] [Indexed: 11/18/2022]
|
12
|
Lermuzeaux M, Meric H, Sauneuf B, Girard S, Normand H, Lofaso F, Terzi N. Superiority of transcutaneous CO2 over end-tidal CO2 measurement for monitoring respiratory failure in nonintubated patients: A pilot study. J Crit Care 2016; 31:150-6. [DOI: 10.1016/j.jcrc.2015.09.014] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2015] [Revised: 09/01/2015] [Accepted: 09/15/2015] [Indexed: 10/23/2022]
|
13
|
Peschanski N, Garcia L, Delasalle E, Mzabi L, Rouff E, Dautheville S, Renai F, Kieffer Y, Lefevre G, Freund Y, Ray P. Can transcutaneous carbon dioxide pressure be a surrogate of blood gas samples for spontaneously breathing emergency patients? The ERNESTO experience. Emerg Med J 2015; 33:325-8. [PMID: 26718224 DOI: 10.1136/emermed-2015-205203] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2015] [Accepted: 11/26/2015] [Indexed: 11/04/2022]
Abstract
BACKGROUND It is known that the arterial carbon dioxide pressure (PaCO2) is useful for emergency physicians to assess the severity of dyspnoeic spontaneously breathing patients. Transcutaneous carbon dioxide pressure (PtcCO2) measurements could be a non-invasive alternative to PaCO2 measurements obtained by blood gas samples, as suggested in previous studies. This study evaluates the reliability of a new device in the emergency department (ED). METHODS We prospectively included patients presenting to the ED with respiratory distress who were breathing spontaneously or under non-invasive ventilation. We simultaneously performed arterial blood gas measurements and measurement of PtcCO2 using a sensor placed either on the forearm or the side of the chest and connected to the TCM4 CombiM device. The agreement between PaCO2 and PtcCO2 was assessed using the Bland-Altman method. RESULTS Sixty-seven spontaneously breathing patients were prospectively included (mean age 70 years, 52% men) and 64 first measurements of PtcCO2 (out of 67) were analysed out of the 97 performed. Nineteen patients (28%) had pneumonia, 19 (28%) had acute heart failure and 19 (28%) had an exacerbation of chronic obstructive pulmonary disease. Mean PaCO2 was 49 mm Hg (range 22-103). The mean difference between PaCO2 and PtcCO2 was 9 mm Hg (range -47 to +54) with 95% limits of agreement of -21.8 mm Hg and 39.7 mm Hg. Only 36.3% of the measurement differences were within 5 mm Hg. CONCLUSIONS Our results show that PtcCO2 measured by the TCM4 device could not replace PaCO2 obtained by arterial blood gas analysis.
Collapse
Affiliation(s)
- Nicolas Peschanski
- Department of Emergency Medicine and Surgery, Centre Hospitalo-Universitaire Tenon Saint Antoine, Assistance-Publique Hôpitaux de Paris (AP-HP), Paris, France Department of Emergency Medicine, Centre Hospitalo-Universitaire Rouen, Rouen, France Institut National de la Sante et de la Recherche Médicale U1096, Université de Rouen, Rouen, France
| | - Léa Garcia
- Department of Emergency Medicine and Surgery, Centre Hospitalo-Universitaire Tenon Saint Antoine, Assistance-Publique Hôpitaux de Paris (AP-HP), Paris, France
| | - Emilie Delasalle
- Department of Emergency Medicine, Centre Hospitalo-Universitaire Rouen, Rouen, France
| | - Lynda Mzabi
- Department of Emergency Medicine and Surgery, Centre Hospitalo-Universitaire Tenon Saint Antoine, Assistance-Publique Hôpitaux de Paris (AP-HP), Paris, France
| | - Edwin Rouff
- Department of Emergency Medicine and Surgery, Centre Hospitalo-Universitaire Tenon Saint Antoine, Assistance-Publique Hôpitaux de Paris (AP-HP), Paris, France
| | - Sandrine Dautheville
- Department of Emergency Medicine and Surgery, Centre Hospitalo-Universitaire Tenon Saint Antoine, Assistance-Publique Hôpitaux de Paris (AP-HP), Paris, France
| | - Fayrouz Renai
- Department of Emergency Medicine and Surgery, Centre Hospitalo-Universitaire Tenon Saint Antoine, Assistance-Publique Hôpitaux de Paris (AP-HP), Paris, France
| | - Yann Kieffer
- Department of Emergency Medicine and Surgery, Centre Hospitalo-Universitaire Tenon Saint Antoine, Assistance-Publique Hôpitaux de Paris (AP-HP), Paris, France
| | - Guillaume Lefevre
- Department of Biochemistry, Centre Hospitalo-Universitaire Tenon Saint Antoine, Paris, France
| | - Yonathan Freund
- Department of Emergency Medicine and Surgery, Groupe Hospitalo-Universitaire Pitié-Salpêtrière, Paris, France DHU Fighting against Ageing and Stress (FAST), Paris Sorbonne Université, Université Paris-06, Paris, France
| | - Patrick Ray
- Department of Emergency Medicine and Surgery, Centre Hospitalo-Universitaire Tenon Saint Antoine, Assistance-Publique Hôpitaux de Paris (AP-HP), Paris, France DHU Fighting against Ageing and Stress (FAST), Paris Sorbonne Université, Université Paris-06, Paris, France
| |
Collapse
|
14
|
Erratum: Concordance and limits between transcutaneous and arterial carbon dioxide pressure in emergency department patients with acute respiratory failure: a single-center, prospective, and observational study. Scand J Trauma Resusc Emerg Med 2015; 23:77. [PMID: 26572985 PMCID: PMC4647282 DOI: 10.1186/s13049-015-0154-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2015] [Accepted: 09/07/2015] [Indexed: 11/24/2022] Open
Abstract
Abstract After publication of this article (Scand J Trauma Resusc Emerg Med 23:40, 2015), it came to light that an earlier version had been published in error. This erratum contains the correct version of the article, which incorporates revisions made in response to reviewer comments. Additionally, one of the authors was inadvertently omitted from the author list. This author, Justin Yan, has been included in the corrected author list above. Background Transcutaneous CO2 (PtCO2) is a continuous and non-invasive measure recommended by scientific societies in the management of respiratory distress. The objective of this study was to evaluate the correlation between PtCO2 and arterial partial pressure of CO2 (PaCO2) by arterial blood gas analysis in emergency patients with dyspnoea, and to determine the factors that interfere with this correlation. Methods From January to June 2014, all adult patients admitted to the RR with dyspnoea during business hours were included in the study if arterial blood gas measurements were indicated. A sensor measuring the PtCO2 was attached to the ear lobe of the patient before the gas analysis. Anamnesis, clinical and laboratory parameters were identified. Results Ninety patients with dyspnoea were included (104 pairs of measurements). The median (IQR) age was 79 years (69 – 85). The correlation between PtCO2 and PaCO2 was R2 =.83 (p<.001) but became lower for values of PaCO2 above 60 mm Hg. The mean bias (± SD) between the two methods of measurement (Bland-Altman analysis) was −1.4 mm Hg (± 7.7) with limits of agreement from −16.4 to 13.7 mm Hg. In univariate analysis, PaO2 interfered with this correlation. After multivariate analysis, temperature (OR = 3.01; 95 % CIs [1.16, 7.80]) and PaO2 (OR = 1.22; 95 % CIs [1.02, 1.47]) significantly interfered with this correlation. Conclusions There is a significant correlation between PaCO2 and PtCO2 values for patients admitted to the emergency department for acute respiratory failure. One limiting factor to routine use of PtCO2 measurements in the emergency department is the presence of hyperthermia.
Collapse
|
15
|
Bobbia X, Claret PG, Palmier L, Robert M, Grandpierre RG, Roger C, Ray P, Sebbane M, Muller L, La Coussaye JED. Concordance and limits between transcutaneous and arterial carbon dioxide pressure in emergency department patients with acute respiratory failure: a single-center prospective observational study. Scand J Trauma Resusc Emerg Med 2015; 23:40. [PMID: 25981461 PMCID: PMC4434821 DOI: 10.1186/s13049-015-0120-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2014] [Accepted: 04/15/2015] [Indexed: 11/27/2022] Open
Abstract
Introduction Transcutaneous CO 2 (PtCO 2) is a continuous and non-invasive measure recommended by scientific societies in the management of respiratory distress. The objective of this study is to evaluate the correlation between PtCO 2 and blood pressure of CO 2 (PaCO 2) by blood gas analysis in emergency patients with dyspnoea and to determine the factors that interfere in this correlation. Methods From January to June 2014, all patients admitted to resuscitation room of the emergency department targeted for arterial blood gases were included prospectively. A sensor measuring the PtCO 2 was attached to the ear lobe of the patient before the gas analysis. Anamnesis, clinical and laboratory parameters were identified. Results 90 patients with dyspnoea were included (with 104 pairs of measurements), the median age was 79 years [69-85]. The correlation between PtCO 2 and PaCO 2 was R 2= 0.83 (p <0.001) but became lower for values of PaCO 2>60 mm Hg. The mean bias (±SD) between the two methods of measurement (Bland-Altman analysis) was -1.4 mm Hg (±7.7) with limits of agreement of -16.4 to 13.7 mm Hg. In univariate analysis, PaO 2 interfered in this correlation. After multivariate analysis, the temperature (OR = 3.01, 95% CI = 1.16-7.09) and the PaO 2 (OR = 1.22, 95% CI = 1.02-1.47) were found to be significant. Conclusions In patients admitted in emergency unit for acute respiratory failure, there is a significant correlation between PaCO 2 and PtCO 2, mainly for values below 60 mm Hg. The two limiting factors of use are hyperthermia and users training.
Collapse
Affiliation(s)
- Xavier Bobbia
- Pôle Anesthésie Réanimation Douleur Urgences, Nîmes University Hospital, 4 Rue du Professeur Robert Debré, Nîmes, 30029, France.
| | - Pierre-Géraud Claret
- Pôle Anesthésie Réanimation Douleur Urgences, Nîmes University Hospital, 4 Rue du Professeur Robert Debré, Nîmes, 30029, France.
| | - Ludovic Palmier
- Pôle Anesthésie Réanimation Douleur Urgences, Nîmes University Hospital, 4 Rue du Professeur Robert Debré, Nîmes, 30029, France.
| | - Michaël Robert
- Pôle Anesthésie Réanimation Douleur Urgences, Nîmes University Hospital, 4 Rue du Professeur Robert Debré, Nîmes, 30029, France.
| | - Romain Genre Grandpierre
- Pôle Anesthésie Réanimation Douleur Urgences, Nîmes University Hospital, 4 Rue du Professeur Robert Debré, Nîmes, 30029, France.
| | - Claire Roger
- Pôle Anesthésie Réanimation Douleur Urgences, Nîmes University Hospital, 4 Rue du Professeur Robert Debré, Nîmes, 30029, France.
| | - Patrick Ray
- Emergency Department, Hôpital Tenon, Assistance Publique - Hôpitaux de Paris, 4 Rue de la Chine, Paris, 75020, France.
| | - Mustapha Sebbane
- Pôle Anesthésie Réanimation Douleur Urgences, Nîmes University Hospital, 4 Rue du Professeur Robert Debré, Nîmes, 30029, France.
| | - Laurent Muller
- Pôle Anesthésie Réanimation Douleur Urgences, Nîmes University Hospital, 4 Rue du Professeur Robert Debré, Nîmes, 30029, France.
| | - Jean-Emmanuel de La Coussaye
- Pôle Anesthésie Réanimation Douleur Urgences, Nîmes University Hospital, 4 Rue du Professeur Robert Debré, Nîmes, 30029, France.
| |
Collapse
|
16
|
Transcutaneous continuous carbon dioxide tension monitoring reduced incidence, degree and duration of hypercapnia during combined regional anaesthesia and monitored anaesthesia care in shoulder surgery patients. J Clin Monit Comput 2014; 29:499-507. [DOI: 10.1007/s10877-014-9627-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2014] [Accepted: 10/07/2014] [Indexed: 10/24/2022]
|
17
|
Shi H, Chen S, Swar G, Wang Y, Ying M. Carbon dioxide insufflation during endoscopic retrograde cholangiopancreatography: a review and meta-analysis. Pancreas 2013; 42:1093-100. [PMID: 23867366 DOI: 10.1097/mpa.0b013e3182909da5] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
OBJECTIVES The role of carbon dioxide (CO2) insufflation during endoscopic retrograde cholangiopancreatography (ERCP) is debated. A meta-analysis was performed to evaluate the efficacy and safety of CO2 insufflation for ERCP. METHODS Searches were conducted in multiple databases composed of Pub-Medline, EMBASE, the Cochrane Library, science citation index expanded, Google scholar, and CNKI China series full-text database. Outcome measurements are listed below: ERCP procedural data, post-ERCP abdominal discomfort, radiographic evaluation of bowel gas volume, and CO2 safety data concerning CO2 elimination. RESULTS Seven published randomized clinical trials involving 756 patients fulfilling the inclusion criteria were selected for meta-analysis, almost all of high quality. The incidence of ERCP-related complications was reduced by CO2 insufflation, so were the events of 1-hour, 3-hour, and 6-hour post-ERCP abdominal pain, based on their corresponding statistical results. Besides, CO2 insufflation was associated with less gas volume in the bowel lumen after the procedure. There were no significant differences between CO2 and air insufflation in total procedure time, the success rate of selective cannulation, post-ERCP abdominal distension, respectively. Subsequent sensitivity and subgroup analyses produced conflicting results. CONCLUSIONS Compared with air insufflation, CO2 insufflation during ERCP reduces post-ERCP abdominal pain, post-ERCP bowel remnant gas volume, and ERCP-related complications, without clinically significant systematic CO2 retention.
Collapse
Affiliation(s)
- Hong Shi
- From the *Department of Gastrointestinal Endoscopy, Fujian Provincial Tumor Hospital, Teaching Hospital of Fujian Medical University, Fuzhou, Fujian, China; †Institute of Minimally Invasive Medicine, Tongji University, Shanghai, China; and ‡Department of Surgery, Fujian Provincial Tumor Hospital, Teaching Hospital of Fujian Medical University, Fuzhou, Fujian, China
| | | | | | | | | |
Collapse
|
18
|
Esquinas AM, Lo Coco D. Non-invasive mechanical ventilation and transcutaneous carbon dioxide monitoring in amyotrophic lateral sclerosis: The silent watchdog. Amyotroph Lateral Scler Frontotemporal Degener 2013; 14:152-3. [DOI: 10.3109/21678421.2012.760607] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
19
|
Kim JY, Yoon YH, Lee SW, Choi SH, Cho YD, Park SM. Accuracy of transcutaneous carbon dioxide monitoring in hypotensive patients. Emerg Med J 2013; 31:323-6. [DOI: 10.1136/emermed-2012-202228] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
ObjectivesContinuous blood gas monitoring is frequently necessary in critically ill patients. Our aim was to assess the accuracy of transcutaneous CO2 tension (PtcCO2) monitoring in the emergency department (ED) assessment of hypotensive patients by comparing it with the gold standard of arterial blood gas analysis (ABGA).MethodsAll patients receiving PtcCO2 monitoring in the ED were included. We excluded paediatric patients, patients with no ABGA results during a hypotensive event, patients whose ABGA was not performed simultaneously with PtcCO2 monitoring, and patients who received sodium bicarbonate for resuscitation. The included patients were classified into hypotensive patients and normotensive patients. A hypotensive patient was defined as a patient showing a mean arterial pressure under 60 mm Hg. The agreement in measurement between PaCO2 tension (PaCO2) and PtcCO2 were investigated in both groups.ResultsThe mean difference between PaCO2 and PtcCO2 was 2.1 mm Hg, and the Bland–Altman limits of agreement (bias±1.96 SD) ranged from −15.6 to 19.7 mm Hg in the 28 normotensive patients. The mean difference between PaCO2 and PtcCO2 was 1.1 mm Hg, and the Bland–Altman limits of agreement (bias±1.96 SD) ranged from −19.5 to 21.7 mm Hg in the 26 hypotensive patients. The weighted κ values were 0.64 in the normotensive patients and 0.60 in the hypotensive patients.ConclusionsPtcCO2 monitoring showed wider limits of agreement with PaCO2 in urgent situations in the ED environment. However, acutely developed hypotension does not affect the accuracy of PtcCO2 monitoring.
Collapse
|