1
|
Houri H, Aghdaei HA, Firuzabadi S, Khorsand B, Soltanpoor F, Rafieepoor M, Tanhaei M, Soleymani G, Azimirad M, Sadeghi A, Ebrahimi Daryani N, Zamani F, Talaei R, Yadegar A, Mohebi SR, Sherkat G, Hagh Azalli M, Malekpour H, Hemmasi G, Zali MR. High Prevalence Rate of Microbial Contamination in Patient-Ready Gastrointestinal Endoscopes in Tehran, Iran: an Alarming Sign for the Occurrence of Severe Outbreaks. Microbiol Spectr 2022; 10:e0189722. [PMID: 36173304 PMCID: PMC9602500 DOI: 10.1128/spectrum.01897-22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2022] [Accepted: 09/06/2022] [Indexed: 12/31/2022] Open
Abstract
An alarmingly increasing number of outbreaks caused by contaminated gastrointestinal (GI) endoscopes are being reported as a particularly concerning issue. This study is the first large-scale multicenter survey to evaluate the contamination of GI endoscopes in Tehran, Iran. This multicenter study was conducted among 15 tertiary referral and specialized gastrointestinal settings. Reprocessed GI endoscopes were sampled by the sequence of the flush-brush-flush method. Bacterial and viral contamination, as well as antimicrobial resistance, were explored by culture and molecular assays. A total of 133 reprocessed and ready-to-use GI endoscopes were investigated. In phase I and phase II, 47% and 32%, respectively, of the GI endoscopes were determined to be contaminated. GI flora was the most prevalent contaminant isolated from GI endoscopes, in which the most predominant bacteria were Pseudomonas aeruginosa, Escherichia coli, and Klebsiella pneumoniae, in both phase I and II evaluations. The majority of the isolated bacteria in the current study were considered multidrug-resistant organisms (MDROs). More importantly, we recovered carbapenem-resistant nonfermentative Gram-negative bacilli (CRNFGNB), carbapenem-resistant Enterobacterales (CRE), extended-spectrum β-lactamase (ESBL)-producing Enterobacterales (ESBL-E), multidrug-resistant Clostridioides difficile, vancomycin-resistant Enterococcus (VRE), and drug-resistant Candida spp. Disconcertingly, our molecular assays revealed contamination of some reprocessed GI endoscopes with hepatitis B virus (HBV), hepatitis C virus (HCV), and even HIV. This multicenter study indicates a higher-than-expected contamination rate among reprocessed and ready-for-patient-use GI endoscopes, which suggests a higher-than-expected endoscopy-associated infection (EAI) risk, and potentially, morbidity and mortality rate, associated with endoscopy procedures in Tehran, Iran. IMPORTANCE In the light of severe outbreaks caused by multidrug-resistant microorganisms due to contaminated GI endoscopes, understanding to what extent GI endoscopes are inadequately reprocessed is crucial. Several studies assessed contamination of GI endoscopes with various outcomes across the world; however, the prevalence and risk factors of contaminated GI endoscopes and potential subsequent nosocomial spread are still unknown in Iran. The present study is the first large-scale multicenter survey to evaluate the microbial contamination of repossessed and ready-to-use GI endoscopes in Tehran, Iran. Our study showed a higher-than-expected contamination rate among reprocessed GI endoscopes, which suggests potential seeding of deadly but preventable outbreaks associated with endoscopy procedures in Iran. These results suggest that the current reprocessing and process control guidelines do not suffice in Iran. The current study is of particular importance and could provide insights into unrecognized and unidentified endoscopy-associated outbreaks in Iran.
Collapse
Affiliation(s)
- Hamidreza Houri
- Foodborne and Waterborne Diseases Research Center, Research Institute for Gastroenterology and Liver Diseases, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Hamid Asadzadeh Aghdaei
- Basic and Molecular Epidemiology of Gastrointestinal Disorders Research Center, Research Institute for Gastroenterology and Liver Diseases, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Sepideh Firuzabadi
- Foodborne and Waterborne Diseases Research Center, Research Institute for Gastroenterology and Liver Diseases, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Babak Khorsand
- Basic and Molecular Epidemiology of Gastrointestinal Disorders Research Center, Research Institute for Gastroenterology and Liver Diseases, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Fatemeh Soltanpoor
- Foodborne and Waterborne Diseases Research Center, Research Institute for Gastroenterology and Liver Diseases, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Maedeh Rafieepoor
- Basic and Molecular Epidemiology of Gastrointestinal Disorders Research Center, Research Institute for Gastroenterology and Liver Diseases, Shahid Beheshti University of Medical Sciences, Tehran, Iran
- Department of Microbiology and Microbial Biotechnology, Faculty of Life Sciences and Biotechnology, Shahid Beheshti University, Tehran, Iran
| | - Mohammad Tanhaei
- Basic and Molecular Epidemiology of Gastrointestinal Disorders Research Center, Research Institute for Gastroenterology and Liver Diseases, Shahid Beheshti University of Medical Sciences, Tehran, Iran
- Department of Microbiology and Microbial Biotechnology, Faculty of Life Sciences and Biotechnology, Shahid Beheshti University, Tehran, Iran
| | - Ghazal Soleymani
- Foodborne and Waterborne Diseases Research Center, Research Institute for Gastroenterology and Liver Diseases, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Masoumeh Azimirad
- Foodborne and Waterborne Diseases Research Center, Research Institute for Gastroenterology and Liver Diseases, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Amir Sadeghi
- Gastroenterology and Liver Diseases Research Center, Research Institute for Gastroenterology and Liver Diseases, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Nasser Ebrahimi Daryani
- Department of Gastroenterology and Hepatology, Tehran University of Medical Sciences, Tehran, Iran
| | - Farhad Zamani
- Gastrointestinal and Liver Diseases Research Center, Iran University of Medical Sciences, Tehran, Iran
| | - Ramin Talaei
- Department of Gastroenterology and Hepatology, School of Medicine, Shahid Modarres Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Abbas Yadegar
- Foodborne and Waterborne Diseases Research Center, Research Institute for Gastroenterology and Liver Diseases, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Seyed Reza Mohebi
- Gastroenterology and Liver Diseases Research Center, Research Institute for Gastroenterology and Liver Diseases, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Ghazal Sherkat
- Faculty of Mashhad Branch, Islamic Azad University, Mashhad, Iran
| | | | - Habib Malekpour
- Gastroenterology and Liver Diseases Research Center, Research Institute for Gastroenterology and Liver Diseases, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Gholamreza Hemmasi
- Gastrointestinal and Liver Diseases Research Center, Iran University of Medical Sciences, Tehran, Iran
| | - Mohammad Reza Zali
- Gastroenterology and Liver Diseases Research Center, Research Institute for Gastroenterology and Liver Diseases, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
2
|
Curtis SJ, Trewin A, McDermott K, Were K, Clezy K, Dempsey K, Walsh N. Electronic monitoring of doffing using video surveillance to minimise error rate and increase safety at Howard Springs International Quarantine Facility. Antimicrob Resist Infect Control 2022; 11:120. [PMID: 36175981 PMCID: PMC9522442 DOI: 10.1186/s13756-022-01155-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2022] [Accepted: 08/26/2022] [Indexed: 11/10/2022] Open
Abstract
Abstract
Background
Safe donning and doffing of personal protective equipment (PPE) are critical to prevent transmission of infectious diseases. Novel strategies to improve infection prevention and control (IPC) adherence can optimise safety. We describe and quantify video surveillance of doffing at an outdoor hotel quarantine facility led by the Australian Medical Assistance Team in the Northern Territory, Australia.
Methods
Motion-activated video cameras were installed in seven areas where personnel doffed PPE upon exit from an area dedicated to quarantined residents. Video footage was reviewed daily and compliance issues were identified using a standardised checklist and risk graded to initiate feedback. We collated audit data from 1 February to 18 April 2021 to describe trends by month, staff group, doffing component and risk.
Results
In 235 h of video footage, 364 compliance issues were identified, of which none were considered high-risk compromising to PPE integrity. Compliance issues were low risk (55/364, 15%) or moderate risk (309/364, 85%) and the most common issue was missed or inadequate hand hygiene (156/364, 43%). Compliance issues per minute of video footage reviewed decreased following introduction of the activity, from 24 per 1000 in February to 7 per 1000 in March and April.
Conclusion
Video surveillance with feedback supported rapid response to improve IPC adherence in a challenging ambient environment. The activity focused on perfection to identify compliance issues that would go unreported in most healthcare settings and contributed to a suit of activities that prevented any high-risk PPE breaches or compromises to safety.
Collapse
|
3
|
Rauwers AW, Voor In 't Holt AF, Buijs JG, Groot WD, Erler NS, Vos MC, Bruno MJ. Assessment of postmanual cleaning adenosine triphosphate tests to prevent the use of contaminated duodenoscopes and linear echoendoscopes: the DETECT study. Gastrointest Endosc 2022; 96:282-290.e5. [PMID: 35341715 DOI: 10.1016/j.gie.2022.03.022] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/20/2021] [Accepted: 03/17/2022] [Indexed: 12/11/2022]
Abstract
BACKGROUND AND AIMS We investigated whether the use of postmanual cleaning adenosine triphosphate (ATP) tests lowers the number of duodenoscopes and linear echoendoscopes (DLEs) contaminated with gut flora. METHODS In this single-center before-and-after study, DLEs were ATP tested after cleaning. During the control period, participants were blinded to ATP results: ATP-positive DLEs were not recleaned. During the intervention period, ATP-positive DLEs were recleaned. DLEs underwent microbiologic sampling after high-level disinfection (HLD) with participants blinded to culture results. RESULTS Using 15 endoscopes of 5 different DLE types, we included 909 procedures (52% duodenoscopes, 48% linear echoendoscopes). During the intervention period, the absolute rate of contamination with gut flora was higher (16% vs 21%). The main analysis showed that contamination was less likely to occur in the intervention period (odds ratio, .32; 95% credible interval [CI], .12-.85). A secondary analysis showed that this effect was based on 1 particular duodenoscope type (estimated probability, 39% [95% CI, 18%-64%] vs 9% [95% CI, 2%-21%]), whereas no effect was seen in the other 4 DLE types. In detail, of the 4 duodenoscopes of this type, 2 had lower contamination rates (69% vs 39% and 36% vs 10%). During the control period, both these duodenoscopes had multiple episodes with ongoing contamination with the same microorganism that ended weeks before the start of the intervention period (ie, they were not terminated by ATP testing). CONCLUSIONS Postmanual cleaning ATP tests do not reduce post-HLD gut flora contamination rates of DLEs. Hence, postcleaning ATP tests are not suited as a means for quality control of endoscope reprocessing.
Collapse
Affiliation(s)
- Arjan W Rauwers
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Centre, Rotterdam, The Netherlands; Department of Medical Microbiology and Infectious Diseases, Erasmus MC University Medical Centre, Rotterdam, The Netherlands
| | - Anne F Voor In 't Holt
- Department of Medical Microbiology and Infectious Diseases, Erasmus MC University Medical Centre, Rotterdam, The Netherlands
| | - Jolanda G Buijs
- Staff Office Medical Devices, Erasmus MC University Medical Centre, Rotterdam, The Netherlands
| | - Woutrinus de Groot
- Department of Medical Microbiology and Infectious Diseases, Erasmus MC University Medical Centre, Rotterdam, The Netherlands
| | - Nicole S Erler
- Department of Biostatistics, Erasmus MC University Medical Centre, Rotterdam, The Netherlands
| | - Margreet C Vos
- Department of Medical Microbiology and Infectious Diseases, Erasmus MC University Medical Centre, Rotterdam, The Netherlands
| | - Marco J Bruno
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Centre, Rotterdam, The Netherlands
| |
Collapse
|
4
|
Chen S, Liu T, Lai H, Chang H, Yen H. Monthly endoscopy surveillance culture facilitates detection of breaches in the scope reprocessing procedure: 5‐year experience in an endoscopy center. ADVANCES IN DIGESTIVE MEDICINE 2021. [DOI: 10.1002/aid2.13251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Affiliation(s)
- Shu‐Hui Chen
- Endoscopy Center, Division of Gastroenterology Changhua Christian Hospital Changhua Taiwan
| | - Theophile Liu
- Center for Infection Prevention and Control Changhua Christian Healthcare System Changhua Taiwan
| | - Huei‐Wen Lai
- Center for Infection Prevention and Control Changhua Christian Healthcare System Changhua Taiwan
| | - Hui‐Lan Chang
- General Education Center Chienkuo Technology University Changhua Taiwan
| | - Hsu‐Heng Yen
- Endoscopy Center, Division of Gastroenterology Changhua Christian Hospital Changhua Taiwan
- General Education Center Chienkuo Technology University Changhua Taiwan
- College of Medicine Chung Shan Medical University Taichung Taiwan
| |
Collapse
|
5
|
Ofstead CL, Buro BL, Hopkins KM, Eiland JE, Wetzler HP, Lichtenstein DR. Duodenoscope-associated infection prevention: A call for evidence-based decision making. Endosc Int Open 2020; 8:E1769-E1781. [PMID: 33269310 PMCID: PMC7671768 DOI: 10.1055/a-1264-7173] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Accepted: 07/30/2020] [Indexed: 02/07/2023] Open
Abstract
Background Recent outbreaks of duodenoscope-associated multidrug-resistant organisms (MDROs) have brought attention to the infection risk from procedures performed with duodenoscopes. Prior to these MDRO outbreaks, procedures with duodenoscopes were considered safe and low risk for exogenous infection transmission, provided they were performed in strict accordance with manufacturer instructions for use and multisociety reprocessing guidelines. The attention and efforts of the scientific community, regulatory agencies, and the device industry have deepened our understanding of factors responsible for suboptimal outcomes. These include instrument design, reprocessing practices, and surveillance strategies for detecting patient and instrument colonization. Various investigations have made it clear that current reprocessing methods fail to consistently deliver a pathogen-free instrument. The magnitude of infection transmission has been underreported due to several factors. These include the types of organisms responsible for infection, clinical signs presenting in sites distant from ERCP inoculation, and long latency from the time of acquisition to infection. Healthcare providers remain hampered by the ill-defined infectious risk innate to the current instrument design, contradictory information and guidance, and limited evidence-based interventions or reprocessing modifications that reduce risk. Therefore, the objectives of this narrative review included identifying outbreaks described in the peer-reviewed literature and comparing the findings with infections reported elsewhere. Search strategies included accessing peer-reviewed articles, governmental databases, abstracts for scientific conferences, and media reports describing outbreaks. This review summarizes current knowledge, highlights gaps in traditional sources of evidence, and explores opportunities to improve our understanding of actual risk and evidence-based approaches to mitigate risk.
Collapse
Affiliation(s)
- Cori L. Ofstead
- Ofstead & Associates, Inc., St. Paul, Minnesota, United States
| | - Brandy L. Buro
- Ofstead & Associates, Inc., St. Paul, Minnesota, United States
| | | | - John E. Eiland
- Ofstead & Associates, Inc., St. Paul, Minnesota, United States
| | | | | |
Collapse
|
6
|
Abstract
Over the past 2 decades, in hospital centers worldwide, there have been numerous outbreaks of multidrug-resistant organisms that have since been attributed to endoscopic transmission of the infections between patients, primarily from duodenoscopes. These outbreaks have focused the attention of endoscope manufacturers, professional societies, and regulatory agencies on improving the reprocessing of these devices. The key steps in this process are point-of-use precleaning, leak testing, manual cleaning, high-level disinfection, and finally drying and storage. The promise of these initial efforts suggest that the aim of minimizing and ultimately eliminating events of endoscope-/duodenoscope-associated transmission of infectious organisms between patients can be achieved.
Collapse
Affiliation(s)
- Neil B Marya
- Vatche and Tamar Manoukian Division of Digestive Diseases, David Geffen School of Medicine at UCLA, 200 UCLA Medical Plaza, Suite 214, Los Angeles, CA 90095, USA
| | - Raman V Muthusamy
- Vatche and Tamar Manoukian Division of Digestive Diseases, David Geffen School of Medicine at UCLA, 200 UCLA Medical Plaza, Suite 214, Los Angeles, CA 90095, USA.
| |
Collapse
|
7
|
Raphael KL, McNoble E, Goldbeck J, Stiles M, Miller LS, Trindade AJ. Remote video auditing in the endoscopy unit for evaluation of duodenoscope reprocessing in a tertiary care center. Endoscopy 2020; 52:864-870. [PMID: 32408362 DOI: 10.1055/a-1157-8861] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
BACKGROUND : A significant proportion of duodenoscope-transmitted infections have resulted from errors related to reprocessing. Remote video auditing (RVA) is a tool that can monitor reprocessing compliance but it has not been previously evaluated in a tertiary care setting. The aims of this study were to evaluate: 1) RVA feasibility in a tertiary care setting (defined as the ability to audit every step of duodenoscope reprocessing without delaying the next procedure due to unavailability of duodenoscopes); and 2) the use of RVA as a compliance monitoring tool. METHODS : This was a prospective study at a tertiary care center. A video camera with offsite monitoring was installed in March 2018. Auditors delivered a compliance score after each procedure. The duodenoscope was not used until it passed the audit. Feasibility and compliance data were collected from April 2018 to August 2019 after a 1-month run-in phase. Both per-step compliance and overall 100 % compliance rates were measured. RESULTS : Of 743 duodenoscope reprocessing procedures, 32 666 individual steps were audited and 99.9 % of the steps were fully viewable. The mean time per audit was 38.3 minutes, the mean duodenoscope turnover time was 76.1 minutes, and there were no delays to the next procedure due to unavailability of duodenoscopes. The per-step compliance rate was 99.5 % but the overall 100 % compliance rate was 90.3 %. CONCLUSIONS : The use of RVA in duodenoscope reprocessing was feasible and promoted sustained high-level compliance in a tertiary care center.
Collapse
Affiliation(s)
- Kara L Raphael
- Division of Gastroenterology, Zucker School of Medicine at Hofstra/Northwell, Long Island Jewish Medical Center, Northwell Health System, New Hyde Park, New York, United States
| | - Ellen McNoble
- Perioperative Patient Care Services, Zucker School of Medicine at Hofstra/Northwell, Long Island Jewish Medical Center, Northwell Health System, New Hyde Park, New York, United States
| | - Jessica Goldbeck
- Hospital Administration, Zucker School of Medicine at Hofstra/Northwell, Long Island Jewish Medical Center, Northwell Health System, New Hyde Park, New York, United States
| | - Megan Stiles
- Hospital Administration, Zucker School of Medicine at Hofstra/Northwell, Long Island Jewish Medical Center, Northwell Health System, New Hyde Park, New York, United States
| | - Larry S Miller
- Division of Gastroenterology, Zucker School of Medicine at Hofstra/Northwell, Long Island Jewish Medical Center, Northwell Health System, New Hyde Park, New York, United States
| | - Arvind J Trindade
- Division of Gastroenterology, Zucker School of Medicine at Hofstra/Northwell, Long Island Jewish Medical Center, Northwell Health System, New Hyde Park, New York, United States
| |
Collapse
|
8
|
Rauwers AW, Voor In 't Holt AF, Buijs JG, de Groot W, Erler NS, Bruno MJ, Vos MC. Nationwide risk analysis of duodenoscope and linear echoendoscope contamination. Gastrointest Endosc 2020; 92:681-691.e1. [PMID: 32502549 DOI: 10.1016/j.gie.2020.05.030] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2019] [Accepted: 05/10/2020] [Indexed: 02/08/2023]
Abstract
BACKGROUND AND AIMS Contaminated duodenoscopes and linear echoendoscopes (DLEs) pose a risk for infectious outbreaks. To identify DLEs and reprocessing risk factors, we combined the data from the previously published nationwide cross-sectional PROCESS 1 study (Prevalence of contamination of complex endoscopes in the Netherlands) with the follow-up PROCESS 2 study. METHODS We invited all 74 Dutch DLE centers to sample ≥2 duodenoscopes during PROCESS 1, and all duodenoscopes as well as linear echoendoscopes during PROCESS 2. The studies took place 1 year after another. Local staff sampled each DLE at ≤6 sites according to uniform methods explained by online videos. We used 2 contamination definitions: (1) any microorganism with ≥20 colony-forming units (CFU)/20 mL (AM20) and (2) presence of microorganisms with GI or oral origin, independent of CFU count (MGOs). We assessed the factors of age and usage by performing an analysis of pooled data of both PROCESS studies; additional factors including reprocessing characteristics were only recorded in PROCESS 2. RESULTS Ninety-seven percent of all Dutch centers (72 of 74; PROCESS 1, 66; PROCESS 2, 61) participated in one of the studies, sampling 309 duodenoscopes and 64 linear echoendoscopes. In total, 54 (17%) duodenoscopes and 8 (13%) linear echoendoscopes were contaminated according to the AM20 definition. MGOs were detected on 47 (15%) duodenoscopes and 9 (14%) linear echoendoscopes. Contamination was not age or usage dependent (all P values ≥.27) and was not shown to differ between the reprocessing characteristics (all P values ≥.01). CONCLUSIONS In these nationwide studies, we found that DLE contamination was independent of age and usage. These results suggest that old and heavily used DLEs, if maintained correctly, have a similar risk for contamination as new DLEs. The prevalence of MGO contamination of ∼15% was similarly high for duodenoscopes as for linear echoendoscopes, rendering patients undergoing ERCP and EUS at risk for transmission of microorganisms.
Collapse
Affiliation(s)
- Arjan W Rauwers
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, the Netherlands
| | - Anne F Voor In 't Holt
- Department of Medical Microbiology and Infectious Diseases, Erasmus MC University Medical Center, Rotterdam, the Netherlands
| | - Jolanda G Buijs
- Staff Office Medical Devices, Erasmus MC University Medical Center, Rotterdam, the Netherlands
| | - Woutrinus de Groot
- Department of Medical Microbiology and Infectious Diseases, Erasmus MC University Medical Center, Rotterdam, the Netherlands
| | - Nicole S Erler
- Department of Biostatistics, Erasmus MC University Medical Center, Rotterdam, the Netherlands
| | - Marco J Bruno
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, the Netherlands
| | - Margreet C Vos
- Department of Medical Microbiology and Infectious Diseases, Erasmus MC University Medical Center, Rotterdam, the Netherlands
| |
Collapse
|
9
|
|
10
|
Getting to zero: Enhanced reprocessing and future directions. TECHNIQUES IN GASTROINTESTINAL ENDOSCOPY 2019. [DOI: 10.1016/j.tgie.2019.150626] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
11
|
Ofstead CL, Hopkins KM, Quick MR, Brooks KB, Eiland JE, Wetzler HP. A Systematic Review of Disposable Sheath Use During Flexible Endoscopy. AORN J 2019; 109:757-771. [PMID: 31135992 DOI: 10.1002/aorn.12699] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Flexible endoscopes are exposed to blood, mucus, and other secretions during procedures. Single-use sheaths are designed to prevent contact between contaminants and reusable endoscope components. This systematic review examined findings from 22 studies that assessed endoscopic sheath use during urologic, gastrointestinal, or respiratory procedures. The evidence showed that sheaths were durable and yielded faster endoscope turnover times because their reusable components did not require high-level disinfection or sterilization. After a brief learning period, health care providers successfully assembled and maneuvered sheathed endoscopes. Patients generally did not experience greater discomfort during procedures in which sheaths were used. Microbial cultures of sheathed endoscopes were negative or similar to unsheathed endoscopes. More research is needed to evaluate the potential effect of disposable sheaths on infection risks. The evidence suggests that sheaths are a viable option for reliably providing a barrier between endoscopes and patients without affecting the quality of endoscopic procedures.
Collapse
|
12
|
Sreeramoju P. Recent advances in understanding the epidemiology of healthcare-associated infections. F1000Res 2019; 8. [PMID: 30740216 PMCID: PMC6348434 DOI: 10.12688/f1000research.15891.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 01/23/2019] [Indexed: 11/20/2022] Open
Abstract
Since the 2014 publication of updates to the Society for Healthcare Epidemiology of America (SHEA) compendium of strategies to reduce healthcare-associated infections, there have been several advances in understanding the epidemiology of these diseases. This review article captures many of the key advances but does not include all of them.
Collapse
Affiliation(s)
- Pranavi Sreeramoju
- University of Texas Southwestern Medical Center at Dallas, Dallas, TX, USA
| |
Collapse
|