Friedrich M, Munro DJ, Auffarth GU, Khoramnia R. Characterisation of Intraocular Lens Injectors. Klin Monbl Augenheilkd 2024; 241:905-916. [PMID: 39146575 DOI: 10.1055/a-2349-2158] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/17/2024]
Abstract
In modern ophthalmic surgery, an intraocular lens (IOL) is commonly implanted into the patient's eye with an IOL injector. Many injectors are available, showing various technological differences, from the early manually loaded injector systems to the modern preloaded injectors. This review aims to give a concise overview of the defining characteristics of injector models and draws attention to complications that may occur during IOL implantation. One can differentiate injectors according to their preoperative preparation (manually loaded or preloaded), their implantation mechanism (push-type or screw-type or combined or automated), the size of the nozzle tip, the presence of an insertion depth control feature, and the injector's reusability. Potential complications are IOL misconfigurations such as a haptic-optic adhesion, adherence of the IOL to the injector plunger, an overriding plunger, uncontrolled IOL rotation, a trapped trailing haptic, or damage to the IOL. Additionally, during IOL implantation, the nozzle can become damaged with scratches, extensions, cracks, or bursts to the tip. While these complications rarely produce long-term consequences, manufacturers should try to prevent them by further improving their devices. Similarly, surgeons should evaluate new injectors carefully to ensure the highest possible surgical safety.
Collapse
Affiliation(s)
- Maximilian Friedrich
- David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University Hospital Heidelberg, Germany
| | - Donald J Munro
- David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University Hospital Heidelberg, Germany
| | - Gerd U Auffarth
- David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University Hospital Heidelberg, Germany
| | - Ramin Khoramnia
- David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University Hospital Heidelberg, Germany
| |
Collapse
|
2
|
Baur ID, Łabuz G, Chychko L, Yildirim TM, Naujokaitis T, Auffarth GU, Khoramnia R. In vivo comparison of implantation behavior and laboratory analysis of two preloaded intraocular lens injectors. Eur J Ophthalmol 2024; 34:766-773. [PMID: 37750504 PMCID: PMC11082425 DOI: 10.1177/11206721231204382] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2023] [Accepted: 09/13/2023] [Indexed: 09/27/2023]
Abstract
PURPOSE We evaluated implantation behavior and injector damage of two different IOL injector systems, the Multisert and the AutonoMe. DESIGN Prospective, randomized, comparative study with laboratory investigation. METHODS We examined used injectors from 48 bilateral cataract cases and assessed video recordings of each Implantation. All eyes were intraindividually randomized for treatment with one of the two IOL injectors. Implantation videos were reviewed for inadvertent events and the time for different implantation steps was determined. The injector nozzle tips were examined using light and scanning electron microscopy (SEM). Damage was graded using the Heidelberg Score for IOL injector damage (HeiScore). Three months postoperatively, IOLs were assessed for material changes. RESULTS Implantation was without critical events in 96 of 96 eyes. Mean implantation time was 41.90 ± 7.11 s with the Multisert and 52.22 ± 12.06 s with the AutonoMe. In the AutonoMe group, we observed 4 eyes (8.3%) with a failed docking attempt, 28 eyes (58.3%) with a haptic adherence, one case (2.1%) of straight leading haptic and 2 cases (4.2%) of intrawound IOL manipulation. There were no events observed in the Multisert group. The mean HeiScore values were 0.87 ± 0.61 and 3.68 ± 0.47 for the AutonoMe and Multisert. 3 months postoperatively, IOL material changes were absent. CONCLUSIONS Both injectors allowed safe and controlled implantation. Using Multisert, implantation behavior was more consistent. The injectors showed different damage profiles with a higher damage score for the Multisert.The study is registered at the German Clinical Trials Register (Deutsches Register Klinischer Studien; reference number: DRKS00007837).
Collapse
Affiliation(s)
- Isabella D Baur
- David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| | - Grzegorz Łabuz
- David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| | - Lizaveta Chychko
- David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| | - Timur M Yildirim
- David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| | - Tadas Naujokaitis
- David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| | - Gerd U Auffarth
- David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| | - Ramin Khoramnia
- David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| |
Collapse
|
3
|
Yan W, Borkenstein AF, Khoramnia R, Borkenstein EM, Auffarth GU. Video analysis of optic-haptic-interaction during hydrophobic acrylic intraocular lens implantation using preloaded injectors. BMC Ophthalmol 2023; 23:515. [PMID: 38115049 PMCID: PMC10729437 DOI: 10.1186/s12886-023-03216-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Accepted: 11/09/2023] [Indexed: 12/21/2023] Open
Abstract
OBJECTIVE To compare the optic-haptic interaction of different hydrophobic acrylic IOLs after using six preloaded injectors. METHODS We reviewed the video-recordings of procedures on a total of 388 eyes that underwent phacoemulsification and intraocular lens (IOL) implantation. For six preloaded injectors: multiSert (Hoya Surgical Optics) [System 1], TECNIS Simplicity (Johnson & Johnson Vision) [System 2], TECNIS iTec (Johnson & Johnson Vision) [System 3], AutonoMe (Alcon, Laboratories) [System 4], Bluesert (Carl Zeiss Meditec) [System 5], and Prosert (OphthalmoPro GmbH) [System 6], we noted in each case the time of IOL delivery and made a descriptive observation of IOL insertion and optic-haptic-interaction. RESULTS We defined standard haptic behavior where the haptics emerged "folded" from the injector and quickly recovered their pre-implantation appearance. The incidence where the leading haptic emerged in a deformed way for System 1 was 20%, System 2: 19%, System 3: 14%, System 4: 56%, System 5: 24% and System 6: 5%. For trailing haptic deformed behavior, the incidence was 36%, 6%, 4%, 8%, 18% and 2%, respectively for Systems 1 to 6. Optic-haptic adhesion occurred in 2% of cases for System 1, 44% for System 2, 52% for System 3, 48% for System 4, and 11% for System 6 (P < 0.05). Adhesion was not found with System 5. CONCLUSIONS We observed different deformed behavior for leading and trailing haptics in the six preloaded systems, some systems had as much as 52% optic-haptic adhesion.
Collapse
Affiliation(s)
- Weijia Yan
- The David J Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Andreas F Borkenstein
- Borkenstein and Borkenstein, Private Practice at Privatklinik Kreuzschwestern, Graz, Austria
| | - Ramin Khoramnia
- The David J Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Eva-Maria Borkenstein
- Borkenstein and Borkenstein, Private Practice at Privatklinik Kreuzschwestern, Graz, Austria
| | - Gerd U Auffarth
- The David J Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
| |
Collapse
|
4
|
Joshi RS. Comparative evaluation of an automated preloaded delivery system with a non-preloaded system. Indian J Ophthalmol 2022; 70:4307-4311. [PMID: 36453335 PMCID: PMC9940551 DOI: 10.4103/ijo.ijo_1635_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Purpose To evaluate a single surgeon's experience with an automated preloaded intraocular lens (IOL) delivery system and a nonpreloaded system. Methods This was a prospective, observational case series. Phacoemulsification was performed under topical anesthesia by creating a temporal clear corneal incision. Patients were consecutively assigned to either the Clareon group (n = 50; the IOL was injected into the capsular bag by using an automated injector system) or the AcrySof group (n = 50; the IOL was injected into the capsular bag by using a conventional injector system). The main outcome measures were ease of implantation, intraoperative complications, postoperative centration, and visual acuity. Results Additional manipulation in the anterior chamber was not required in 38 (74%) eyes in the Clareon group and 41 (82%) eyes in the AcrySof group. However, seven eyes in the Clareon group and one eye in the AcrySof group required trailing haptic dislodgement from the optic. Furthermore, two eyes in the Clareon group and five eyes in the AcrySof group required injector rotation (varying from 10° to 90°) in the wound. Moreover, in two eyes of the Clareon group, the silicon plunger of the injector system crossed over the optic. None of the patients developed iris trauma and PCR during IOL manipulation. All the IOLs were centered in the capsular bag. Conclusion The automated IOL delivery system enables the controlled delivery of an IOL in the capsular bag. The effect of carbon footprints created by plastic generated from the delivery system and the implications of the CO2 cylinder on the environment should be addressed.
Collapse
Affiliation(s)
- Rajesh S Joshi
- Department of Ophthalmology, Government Medical College, Nagpur, Maharashtra, India,Correspondence to: Dr. Rajesh S Joshi, 77, Panchatara Housing Society, Manish Nagar, Somalwada, Nagpur - 440 015, Maharashtra, India. E-mail:
| |
Collapse
|
5
|
Zhang L, Schickhardt S, Fang H, Auerbach F, Cagampang P, Merz PR, Auffarth GU. Comparison of a new IOL injector system against 3 standard IOL injector systems with different incision sizes: Miyake-Apple view experimental laboratory study. J Cataract Refract Surg 2022; 48:230-237. [PMID: 34224477 PMCID: PMC8845526 DOI: 10.1097/j.jcrs.0000000000000736] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Accepted: 06/21/2021] [Indexed: 11/26/2022]
Abstract
PURPOSE To compare 1 new intraocular lens (IOL) injector system against 3 standard injector systems in porcine eyes. SETTING David J Apple Center for Vision Research, Department of Ophthalmology, University Hospital Heidelberg, Heidelberg, Germany. DESIGN In vitro laboratory study. METHODS In 70 porcine eyes, +20.0 diopter IOLs were implanted with the following systems: multiSert, UltraSert, iTec, and RayOne, that is, S1.8 (incision size: 1.8 mm), S2.0 (2.0 mm), S2.2P (2.2 mm, push mode), S2.2S (2.2 mm, screw mode), U2.2 (2.2 mm), iT2.2 (2.2 mm), and R2.0 (2.0 mm). Corneal incision sizes were measured before and after implantation with an incision gauge set. Ease of use was evaluated using a Likert scale. IOL delivery time and performance were determined based on Miyake-Apple view videos. RESULTS Of the 70 eyes studied, the incision enlargements were 0.36 ± 0.08 mm (S1.8), 0.15 ± 0.07 mm (S2.0), 0.17 ± 0.12 mm (S2.2P), 0.28 ± 0.10 mm (S2.2S), 0.32 ± 0.09 mm (U2.2), 0.30 ± 0.08 mm (iT2.2), and 0.35 ± 0.11 mm (R2.0). Total scores of ease of use were 23.00 (S1.8), 25.00 (S2.0), 29.00 (S2.2P), 26.00 (S2.2S), 26.00 (U2.2), 25.00 (iT2.2), and 24.00 (R2.0). As for the mean delivery time, iT2.2 took the longest time (13.20 ± 3.29 seconds), whereas S2.2S took the shortest time (4.50 ± 0.71 seconds). Optic-haptic adhesion was observed in S1.8 (4, 40%), S2.2P (2, 20%), U2.2 (5, 50%), and iT2.2 (5, 50%). CONCLUSIONS Injector S, with the appropriate incision size and implantation method, could achieve better results regarding incision enlargement, ease of use, delivery time, and performance than other injector systems. There was an indirect relationship between incision size and inadvertent events.
Collapse
|
6
|
Refractive Outcomes after Cataract Surgery. Diagnostics (Basel) 2022; 12:diagnostics12020243. [PMID: 35204334 PMCID: PMC8870878 DOI: 10.3390/diagnostics12020243] [Citation(s) in RCA: 22] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Revised: 01/14/2022] [Accepted: 01/15/2022] [Indexed: 01/19/2023] Open
Abstract
A post-operative manifest refractive error as close as possible to target is key when performing cataract surgery with intraocular lens (IOL) implantation, given that residual astigmatism and refractive errors negatively impact patients’ vision and satisfaction. This review explores refractive outcomes prior to modern biometry; advances in biometry and its impact on patients’ vision and refractive outcomes after cataract surgery; key factors that affect prediction accuracy; and residual refractive errors and the impact on visual outcomes. There are numerous pre-, intra-, and post-operative factors that can influence refractive outcomes after cataract surgery, leaving surgeons with a small “error budget” (i.e., the source and sum of all influencing factors). To mitigate these factors, precise measurement and correct application of ocular biometric data are required. With advances in optical biometry, prediction of patient post-operative refractory status has become more accurate, leading to an increased proportion of patients achieving their target refraction. Alongside improvements in biometry, advancements in microsurgical techniques, new IOL technologies, and enhancements to IOL power calculations have also positively impacted patients’ refractory status after cataract surgery.
Collapse
|
7
|
Long-Term Clinically Significant Posterior Capsular Opacification Development Pattern in Eyes Implanted with an Aspheric Monofocal Intraocular Lens with a Square Optic Edge. J Ophthalmol 2021; 2021:4566436. [PMID: 34631162 PMCID: PMC8497157 DOI: 10.1155/2021/4566436] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Revised: 09/22/2021] [Accepted: 09/23/2021] [Indexed: 11/26/2022] Open
Abstract
Purpose To analyse the posterior capsular opacification (PCO) development pattern in the long term in eyes implanted with a monofocal intraocular lens (IOL) with a square edge all around the optic. Methods Longitudinal retrospective study is data analyzed from a total of 7059 eyes from 4764 patients (mean age: 75.8 years) undergoing cataract surgery with implantation of an aspheric monofocal IOL (Bi-Flex HL 677AB/677P, Medicontur, Budapest, Hungary). These data were retrospectively collected using the electronic medical record of the hospitals involved. Nd : YAG capsulotomy rates were calculated per year during a follow-up of more than 10 years. The Kaplan–Meier analysis was used to establish the transparent capsule survival rate. Results The Nd : YAG capsulotomy rate increased from 1.1% at 1 year postoperatively to 17.2% at 5 years after surgery. No significant differences were found between eyes with and without capsulotomy in terms of age (p = 0.202), gender (p = 0.061), type of anaesthesia used (p = 0.128), and presence of conditions such as hard cataract (p = 0.111) or pseudoexfoliation (p = 0.137). IOL power was significantly lower in those eyes of patients requiring Nd : YAG capsulotomy during the follow-up (p < 0.001). Significantly more eyes implanted with the preloaded model of the IOL required capsulotomy (p < 0.001). Mean survival time and rate were 9.38 years and 85.9%, respectively. Conclusions Most eyes undergoing cataract with implantation of the Bi-Flex IOL do not develop a clinically significant PCO requiring Nd : YAG capsulotomy in the long term. IOL material and design may be the main factors accounting for this finding.
Collapse
|
8
|
Khoramnia R, Yildirim TM, Weindler J, Naujokaitis T, Dzhambazova M, Auffarth GU. Preloaded injectors used in a clinical study: videographic assessment and laboratory analysis of injector nozzle damage. J Cataract Refract Surg 2021; 47:1338-1344. [PMID: 34469394 DOI: 10.1097/j.jcrs.0000000000000587] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Accepted: 01/14/2021] [Indexed: 11/26/2022]
Abstract
PURPOSE To evaluate quality and duration of implantation of 2 preloaded intraocular lens (IOL) injectors and assess postimplantation damage. SETTING The David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany. DESIGN Prospective, randomized, comparative study with laboratory investigation. METHODS Implantation videos and postuse injectors from 60 paired eyes of 30 bilateral cataract patients were included. Patient eyes were randomly assigned for implantation with 2 different preloaded injectors: the AutonoMe with a Clareon IOL (Alcon Laboratories, Inc.) and the iSert with a Vivinex IOL (Hoya Corp.). Videos were reviewed for events during the implantation procedure, and the duration of each step of implantation. Injector nozzles were examined under light and scanning electron microscopy. Damage was graded and correlated with the IOL power. Three months postoperatively IOLs were assessed for material changes. RESULTS IOL delivery was without any critical events in 60 of the 60 eyes. The implantation took 56 seconds with the AutonoMe and 44 seconds with the iSert (P < .05). Most AutonoMe injectors (29; 97%) showed no damage or slight deformation. In most of the iSert injectors (25; 80%), short or extended cracks were present, and damage lengths correlated with the IOL power. All IOLs were free of material changes, including glistenings, 3 months postoperatively. CONCLUSIONS Both preloaded IOL injectors allowed a safe and convenient IOL delivery. Implantation of the Clareon IOL took, on average, slightly longer than that of the Vivinex IOL, mostly due to a slower IOL unfolding. The AutonoMe showed less nozzle tip damage than that of the iSert.
Collapse
Affiliation(s)
- Ramin Khoramnia
- From the The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
| | | | | | | | | | | |
Collapse
|
9
|
Yildirim TM, Łabuz G, Baur ID, Poompokawat P, Knorz MC, Auffarth GU, Khoramnia R. Corneal Incision Enlargement in Two Preloaded Intraocular Lens Injectors: An Intraindividual In Vivo Study. J Refract Surg 2021; 37:331-336. [PMID: 34044690 DOI: 10.3928/1081597x-20210204-01] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To assess enlargement of the clear corneal incision site and functional outcome in patients with cataract, following the use of two preloaded intraocular lens (IOL) injectors. METHODS In this prospective, randomized, intraindividual comparative clinical study, 58 paired-eyes were randomly assigned for implantation with two preloaded injectors: AutonoMe with a Clareon IOL (Alcon Laboratories, Inc) and iSert with a Vivinex IOL (Hoya). The size of the corneal incision, 2 mm for the iSert and 2.2 mm for the AutonoMe, was measured before and after phacoemulsification and after IOL implantation. Patients were examined 3 months after surgery to assess keratometry, subjective refraction, and visual acuity. RESULTS The incision enlargement was 0.20 ± 0.10 mm for the AutonoMe and 0.29 ± 0.10 mm for the iSert, with a statistically significant difference (P < .05). The final wound size after IOL implantation was 2.41 mm for the AutonoMe and 2.35 mm for the iSert. The mean absolute surgically induced astigmatism (SIA) was 0.50 ± 0.25 diopters (D) in the iSert eyes and 0.45 ± 0.20 D in the AutonoMe eyes (P > .05). The 3-month postoperative uncorrected and corrected distance visual acuity (UDVA and CDVA) were similar in both groups, with a UDVA of 0.10 and 0.12 logMAR and CDVA of -0.04 and -0.03 logMAR, respectively for the AutonoMe and iSert. CONCLUSIONS The iSert injector caused more enlargement of the corneal wound during IOL implantation compared to the AutonoMe. Despite the initially different incision sizes, the final incision size and functional outcomes were similar in both groups. [J Refract Surg. 2021;37(5):331-336.].
Collapse
|
10
|
Experimental Study on Delivery Performance of an Automated Preloaded Intraocular Lens Injector System for Corneal and Sclerocorneal Incisions. J Ophthalmol 2021; 2021:5548493. [PMID: 33859834 PMCID: PMC8026288 DOI: 10.1155/2021/5548493] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Revised: 03/21/2021] [Accepted: 03/24/2021] [Indexed: 11/17/2022] Open
Abstract
Purpose To evaluate delivery performance of an automated preloaded intraocular lens (IOL) injector systems (AutonoMe) in the porcine eyes. Methods In the freshly excised porcine eyes, lens removal and IOL implantation were performed. There were 4 groups (10 eyes per group) with different incision site and size: 2.2-mm and 2.4-mm corneal incisions and 2.2-mm and 2.4-mm sclerocorneal incisions. Delivery performance and wound enlargement of AutonoMe were analyzed and compared with those of iTec and iSert from a previous study. Results There were a few minor troubles associated with AutonoMe, such as overriding plunger within cartridge and trapped trailing haptic during IOL insertion, but the incidence was low. Other interactions were not observed, such as IOL adherence to plunger, sudden ejection of IOL, intrawound lens manipulation, IOL behavior, and gross damage to IOL. AutonoMe caused significantly less wound enlargement for both corneal and sclerocorneal incisions than other injector devices. Wound enlargement by using AutonoMe was significantly smaller with 2.4-mm corneal incision than with 2.2-mm corneal incision, but the final incision size was still smaller with 2.2-mm corneal incision. For sclerocorneal incisions, the amount of wound stretch was not different between 2.2 and 2.4 mm incisions. Conclusion The wound enlargement caused by the automated preloaded insertion system, AutonoMe, was smaller than that of other preloaded injectors for both corneal and sclerocorneal incisions. There were a few minor technical events during IOL insertion, but the overall incidence was low.
Collapse
|
11
|
Uveal and capsular biocompatibility of a new hydrophobic acrylic microincision intraocular lens. J Cataract Refract Surg 2021; 46:459-464. [PMID: 32079847 DOI: 10.1097/j.jcrs.0000000000000117] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To evaluate uveal biocompatibility and capsular bag opacification of a new hydrophobic acrylic microincision intraocular lens (IOL) in comparison with a commercially available 1-piece hydrophobic acrylic IOL. SETTING John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. DESIGN Experimental study. METHODS Eight New Zealand rabbits underwent bilateral phacoemulsification and implantation of the preloaded Nanex multiSert IOL in one eye and a commercially available preloaded lens (AcrySof IQ in UltraSert, model AU00T0) in the contralateral eye. A slitlamp examination was performed weekly for 4 weeks. The rabbits were then killed humanely and their globes enucleated. Capsular bag opacification was assessed from the Miyake-Apple view, and the eyes were subjected to histopathologic evaluation. RESULTS Postoperative inflammatory reactions were similar between the test and control eyes in the 8 New Zealand rabbits. The mean postmortem central posterior capsule opacification (PCO) was 0.93 ± 0.73 in the test group and 1.19 ± 0.53 in the control group. The mean postmortem peripheral PCO was 1.75 ± 0.92 in the test group and 2.06 ± 0.77 in the control group. Central and peripheral PCO scores were not statistically different between the test and control groups (P = .41 and P = .35, respectively, 2-tailed t test: paired 2-sample for means). CONCLUSIONS A new 1-piece hydrophobic acrylic microincision IOL incorporating an ultraviolet-ozone treatment on the posterior surface performed similarly to a commercially available 1-piece hydrophobic acrylic IOL in terms of uveal and capsular biocompatibility in the rabbit model. To our knowledge, this is the first hydrophobic acrylic microincision IOL to demonstrate similar PCO performance when compared with a conventional, commercially available IOL.
Collapse
|
12
|
Black D, Corbett D, Roberts TV, Cronin B, Smith PJ, Janakiraman DP, Jackson BE. Clinical Evaluation of a Novel Preloaded Intraocular Lens Delivery System During Routine Cataract Surgery. Clin Ophthalmol 2020; 14:2291-2300. [PMID: 32943830 PMCID: PMC7468508 DOI: 10.2147/opth.s260925] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2020] [Accepted: 07/08/2020] [Indexed: 11/23/2022] Open
Abstract
Purpose To evaluate the clinical handleability and acceptability of a novel preloaded intraocular lens (IOL) delivery system for implantation of the TECNIS ZCB00 IOL (Johnson & Johnson Surgical Vision, Inc., Santa Ana, CA, USA) during routine small-incision cataract surgery. Subjects and Methods In this prospective, open-label, noncomparative, unilateral or bilateral, multicenter study, adult subjects with unilateral or bilateral cataracts scheduled for IOL implantation were enrolled. Surgeons and surgical technicians completed per-eye day-of-surgery and end-of-surgical-day questionnaires. The primary endpoint of the study was the rate of acceptable overall clinical performance of the preloaded IOL delivery system. Other endpoints included additional responses from the questionnaires, preimplantation incision size, and safety. Results The study included 91 eyes that underwent cataract surgery and IOL implantation using the preloaded delivery system and were available for the 1-day postoperative visit. Five surgeons and 14 surgical technicians from four investigational sites participated in the study. The rate of acceptable overall clinical performance was 100% (91/91) of eyes, with most responses (78/91; 85.7%) being the highest possible rating of 5 (very satisfied). Favorable responses by most surgeons and surgical technicians regarding additional endpoints further highlighted the handleability and acceptability of the preloaded delivery system. No ocular adverse events or lens findings (ie, no cases of IOL instability, haptic breakage, IOL marking, or crimping) were reported. Conclusion The results of this study demonstrated that this preloaded IOL delivery system was safe and effective during routine small-incision cataract surgery. Trial Registration German Clinical Trials Register identifier, DRKS00014757.
Collapse
Affiliation(s)
- Daniel Black
- Sunshine Eye Clinic, Birtinya, Queensland, Australia
| | | | - Timothy V Roberts
- Sydney Medical School, The University of Sydney, Sydney, New South Wales, Australia.,Vision Eye Institute, Sydney, New South Wales, Australia
| | - Brendan Cronin
- Queensland Eye Institute, South Brisbane, Queensland, Australia
| | - Pamela J Smith
- Johnson & Johnson Surgical Vision, Inc., Santa Ana, CA, USA
| | | | - Beth E Jackson
- Johnson & Johnson Surgical Vision, Inc., Santa Ana, CA, USA
| |
Collapse
|
13
|
Bedar MS, Kellner U. [Clinical experience with the Clareon® IOL and the AutonoMe® implantation system]. Ophthalmologe 2020; 117:1100-1104. [PMID: 32112221 DOI: 10.1007/s00347-020-01075-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
BACKGROUND The AutonoMe® implantation system with a preloaded, monofocal, aspherical, hydrophobic Clareon® intraocular lens (IOL) has recently become available. The aim of this analysis was the most comprehensive review of intraoperative and postoperative outcomes to date. METHODS Prospective evaluation of intraoperative features in all eyes scheduled to have cataract surgery with Clareon® IOL implantation using the AutonoMe® implantation system between December 2017 and September 2018 with follow-up at 4-6 weeks. Inclusion of all patients, regardless of comorbidities and accompanying ocular surgery. RESULTS A total of 391 eyes were evaluated for the intraoperative analysis and 144 eyes were evaluated for postoperative follow-up. There was one IOL-associated intraoperative complication in which the posterior haptic was not correctly loaded and should not have been implanted. The best corrected distance visual acuity (BCDVA) increased from a mean of 0.33 logMAR (SD 0.21) preoperatively to 0.09 logMAR (SD 0.21) postoperatively, independent of ocular comorbidities. The BCDVA in patients without ocular comorbidities increased from 0.27 logMAR (SD 0.13) preoperatively to 0.03 logMAR (SD 0.05) postoperatively. Using the SRK®/T formula 87.5% of all eyes had a refractive error of ≤0.5 D and 98.0% had a refractive error of ≤1 D 4-6 weeks after surgery. CONCLUSION This study showed that using the recommended safety guidelines, the AutonoMe® system enables safe implantation of the IOL. The Clareon® IOL showed good postoperative visual outcomes and refraction results using the SRK®/T formula.
Collapse
Affiliation(s)
- Mohammad Seleman Bedar
- AugenZentrum Siegburg, MVZ Augenärztliches Diagnostik & Therapiecentrum Siegburg GmbH, Europaplatz 3, 53721, Siegburg, Deutschland.
| | - Ulrich Kellner
- AugenZentrum Siegburg, MVZ Augenärztliches Diagnostik & Therapiecentrum Siegburg GmbH, Europaplatz 3, 53721, Siegburg, Deutschland
- RetinaScience, Bonn, Deutschland
| |
Collapse
|
14
|
In vivo and in vitro results of an automated preloaded delivery system for IOL implantation in cataract surgery. Int Ophthalmol 2019; 40:125-134. [PMID: 31451986 DOI: 10.1007/s10792-019-01154-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2019] [Accepted: 08/14/2019] [Indexed: 10/26/2022]
Abstract
PURPOSE To compare the corneal tissue trauma after the use of an automated preloaded injector and a manual injector and assess scanning electron microscope (SEM) and atomic force microscope (AFM) features of both injector cartridges. SETTING Ophthalmology Clinic and Laboratory of Stem Cells and Regenerative Medicine University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy; DESIGN: Prospective randomized clinical study METHODS: Forty eyes of 40 patients for phacoemulsification were divided into two groups: implantation of intraocular lens was performed with AutonoMe automated delivery system (AutonoMe group: 20 eyes) and Monarch III injector system (Monarch group: 20 eyes). In vivo confocal microscopy (IVCM) and anterior segment optical coherence tomography (AS-OCT) were performed before surgery, at 1 h, 1 day and 1 month post-operatively. In addition, SEM and AFM were performed on cartridges of both injector systems after injection of the IOL. RESULTS A greater increase in central corneal thickness and corneal thickness at the incision site were observed in Monarch group versus AutonoMe group 1 h and 1 day post-operatively (p < 0.05). Endothelial cell count loss was significantly higher in Monarch group compared with AutonoMe group (p < 0.05) at 1 and 24 h. AS-OCT showed less endothelial misalignment at 30 days (p < 0.05), and IVCM showed less tunnel inflammation at all time points (p < 0.05) in AutonoMe group compared with Monarch group; roughness analysis at AFM of the AutonoMe cartridge was significantly lower compared to Monarch D cartridge (p < 0.05). CONCLUSIONS The AutonoMe injector provided less corneal tissue trauma compared with Monarch III injector. The AutonoMe cartridge showed lower roughness at AFM compared to the Monarch D cartridge.
Collapse
|
15
|
Oshika T, Wolfe P. In vitro comparison of delivery performance of 4 preloaded intraocular lens injector systems for corneal and sclerocorneal incisions. J Cataract Refract Surg 2019; 45:840-846. [DOI: 10.1016/j.jcrs.2018.10.050] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2018] [Revised: 10/03/2018] [Accepted: 10/24/2018] [Indexed: 11/16/2022]
|
16
|
In vitro delivery performance assessment of a new preloaded intraocular lens delivery system. J Cataract Refract Surg 2018; 42:1814-1820. [PMID: 28007114 DOI: 10.1016/j.jcrs.2016.10.014] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2016] [Revised: 10/03/2016] [Accepted: 10/05/2016] [Indexed: 11/24/2022]
Abstract
PURPOSE To compare the delivery performance of a new preloaded intraocular lens (IOL) delivery system (Ultrasert [system U]) with that of 2 commercially available preloaded systems (iSert [system S] and Tecnis iTec [system T]), and a manual system (Monarch III D). SETTING Alcon Laboratories, Fort Worth, Texas, USA. DESIGN Experimental study. METHODS Freshly excised porcine eyes were randomly assigned to 5 groups of 10 eyes each as follows: preloaded systems U, S, T 2.2 mm incision, T 2.4 mm incision, and manual system. Corneal incision size was measured before and after delivery. The rate of successful in-the-bag IOL delivery, IOL adherence to the plunger tip, trapped trailing haptic, and presence of nozzle tip splitting were assessed. Statistical analysis was performed to determine the significance of differences between groups. RESULTS All systems successfully placed the IOL in the capsular bag. System U had the least corneal incision enlargement (mean 0.07 mm ± 0.05 [SD]) and the smallest final incision size (mean 2.31 ± 0.06 mm) (P < .05). An associated split in the nozzle tip was observed for system S devices (P < .05). Furthermore, in more than 50% of deliveries with system T, the IOL remained adhered to the plunger tip after exiting the nozzle (P < .05). Systems S and T each had 1 occurrence of a trapped trailing haptic during IOL delivery. CONCLUSION The new design of the system U with a depth-guard nozzle tip allowed for the smallest incision enlargement with an absence of nozzle tip splitting and uneventful IOL delivery compared with the other preloaded systems tested in this study. FINANCIAL DISCLOSURE Drs. Tjia and Lane are consultants to Alcon Laboratories, Inc. Drs. Wang, Wolfe, Paliwal, and Miss Chernosky are employees of Alcon Laboratories, Inc.
Collapse
|
17
|
Acar B, Torun IM, Acar S. Evaluation of Preloaded IOL Delivery System and Hydrophobic Acrylic Intraocular Lens in Cataract Surgery. Open Ophthalmol J 2018; 12:94-103. [PMID: 30008971 PMCID: PMC6008983 DOI: 10.2174/1874364101812010094] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2017] [Revised: 04/10/2018] [Accepted: 05/08/2018] [Indexed: 11/30/2022] Open
Abstract
Background: Advancements in cataract surgery have necessitated the availability of intraocular lens preloaded delivery systems that can safely, effectively and predictably deliver IOLs in the eye. Preloaded delivery systems simplify and reduce procedural variability during surgery preparation. Objective: The objective of this study was to evaluate clinical acceptability, delivery characteristics and clinical outcomes in patients implanted with new generation hydrophobic acrylic Intraocular Lens with Preloaded delivery system. Methods: This was a single centre retrospective study. Total 41 patients were enrolled in the study to get at least 38 patients for evaluation. All patients were assessed on day1 and 1, 3 and 6 months after surgery. Results: EYECRYL-SERT showed ‘excellent’ ease of insertion and handling in all 41(100%) patients. Corrected Distance Visual Acuity (CDVA) improved from 0.74±0.58 logMAR during screening to 0.03±0.04 logMAR 6 months after surgery. The Corrected Intermediate Visual Acuity (CIVA) and Corrected Near Visual Acuity (CNVA) were 0.10±0.04 and 0.01±0.02 logMAR post 6 months surgery, respectively. The refractive spherical equivalence was -1.94±2.51 D during screening, which improved significantly (p=0.0018) to -0.21±0.47 D post 6 months surgery. The low and high contrast sensitivity was 0.06±0.06 and -0.05±0.06 logMAR after 6 months surgery, respectively. The endothelial cell loss was 5.67%, 7.22% and 9.75% at 1, 3, and 6 months after surgery, respectively, as compared to screening. None of the subjects reported any adverse event during the study period. Conclusion: The IOL delivery system (EYECRYL_SERT) provided desired delivery characteristics during cataract surgery and was effective in improving clinical outcomes in cataract patients.
Collapse
Affiliation(s)
| | - Isil M Torun
- Igdir State Hospital, Ophthalmology Clinic, Merkez, Igdir, Turkey
| | | |
Collapse
|
18
|
Rateb MF, Eldaly ZH, Ibrahim WSE, Eldoghaimy AH. Scanning electron microscopic characteristics of manually loaded and preloaded foldable acrylic intraocular lenses. Eur J Ophthalmol 2018; 29:28-32. [PMID: 29619847 DOI: 10.1177/1120672118762665] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE: To compare surface alterations between preloaded and manually loaded intraocular lens. METHODS: Scanning electron microscope was utilized to evaluate surface alteration and deposits in four different types of intraocular lenses: preloaded hydrophobic acrylic, preloaded hydrophilic acrylic, manually loaded hydrophobic acrylic, and manually loaded hydrophilic acrylic. Six lenses with different powers (+6 D, +22 D, and +29 D) were used from each category, to represent different thickness categories of the intraocular lenses. RESULTS: In total, 30 intraocular lenses have been evaluated in this study: 4 from the control group (2 hydrophobic and 2 hydrophilic lenses) and 12 from the preloaded intraocular lens and manually loaded groups (6 hydrophilic and 6 hydrophobic lenses with different powers). Surface deposits were found in eight hydrophobic intraocular lenses compared to a single intraocular lens with scattered deposits on the optical surface of a hydrophilic intraocular lens. In manually loaded intraocular lens group, five hydrophobic and one hydrophilic intraocular lenses showed identifiable marks on the optical surface. In the preloaded intraocular lens group, three hydrophobic intraocular lenses showed identifiable marks on the optical surface and three hydrophobic intraocular lenses showed surface wrinkling. All hydrophilic intraocular lenses revealed no identifiable marks. CONCLUSION: Surface alterations and deposits are a common finding in both preloaded and manually loaded intraocular lenses. Water content of acrylic intraocular lenses is an important factor predisposing to these changes, and hydrophobic intraocular lenses are more vulnerable than hydrophilic lenses. The impact on the final visual outcome needs further studies.
Collapse
Affiliation(s)
| | - Zeiad Hasan Eldaly
- 1 Department of Ophthalmology, Assiut University Hospitals, Assiut, Egypt
| | | | | |
Collapse
|
19
|
|
20
|
Chung B, Lee H, Choi M, Seo KY, Kim EK, Kim TI. Preloaded and non-preloaded intraocular lens delivery system and characteristics: human and porcine eyes trial. Int J Ophthalmol 2018; 11:6-11. [PMID: 29375983 DOI: 10.18240/ijo.2018.01.02] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2017] [Accepted: 10/19/2017] [Indexed: 11/23/2022] Open
Abstract
AIM To compare characteristics of preloaded and non-preloaded intraocular lens (IOL) delivery systems during IOL delivery procedures. METHODS Total 101 human eyes were included in this prospective observational case series. Delivery characteristics of 5 types of IOLs including iSert250 NC60 (NC60), EnVista MX60 (MX60), AcrySof IQ SN60WF (SN60WF), TECNIS ZCB00 (ZCB00), and TECNIS PCB00 (PCB00) were investigated. NC60 and PCB00 were injected via preloaded delivery systems and other IOLs were injected via non-preloaded systems. In the human trial, time taken from IOL loading to completion of implantation was measured in all eyes undergoing conventional cataract surgery. Using 4 excised porcine eyes, dynamics of ophthalmic viscosurgical device (OVD) between an IOL injector and a porcine eye was analyzed using fluorescein sodium-stained OVD. RESULTS The average time for IOL implantation was 22.0s for NC60, 43.2s for MX60, 32.3s for SN60WF, 41.4s for ZCB00, and 14.6s for PCB00 respectively. The number of cases with IOL manipulation with a second instrument was 6 for MX60, 2 for ZCB00, 0 for SN60WF, NC60, and PCB00. Amount of OVD pushed into a porcine eye was smaller with a preloaded system than with non-preloaded systems. CONCLUSION IOL delivery with preloaded systems is faster and more predictable. Moreover, a preloaded delivery system shows relatively less OVD pushed into a porcine eye than non-preloaded systems.
Collapse
Affiliation(s)
- Byunghoon Chung
- The Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul 03722, Korea
| | - Hun Lee
- The Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul 03722, Korea.,Department of Ophthalmology, International St. Mary's Hospital, Catholic Kwandong University College of Medicine, Incheon 22711, Korea
| | - Moonjung Choi
- The Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul 03722, Korea
| | - Kyoung Yul Seo
- The Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul 03722, Korea
| | - Eung Kweon Kim
- The Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul 03722, Korea.,Corneal Dystrophy Research Institute, Yonsei University College of Medicine, Seoul 03722, Korea
| | - Tae-Im Kim
- The Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul 03722, Korea
| |
Collapse
|