1
|
Ichikawa K, Tanaka Y, Tokiwa S, Naito A, Hidaka Y, Ichikawa R, Ichikawa K, Yamamoto N. Comparison of INTREPID® balanced and hybrid tips on anterior capsule rupture in ex vivo porcine eyes. PLoS One 2023; 18:e0290657. [PMID: 37643177 PMCID: PMC10464992 DOI: 10.1371/journal.pone.0290657] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Accepted: 08/11/2023] [Indexed: 08/31/2023] Open
Abstract
Phacoemulsification has emerged as the global standard for cataract surgery, and various novel methods, tools, and agents have promoted surgical efficiency and reduced complications. Conventionally, the phaco tip, which cleaves and aspirates the cataractous lens, has been mainly constructed of metal. In this study, the risk of anterior capsule rupture was evaluated under conditions of different power modes, longitudinal (Mode-L), torsional (Mode-T), or both (Mode-LT), and different aspiration powers (0 or 200 mmHg), using a traditional metal phaco tip (Group-M) or a new phaco tip with a high-strength polymer overmold on the needle edge (Group-P), which was developed to reduce the risk of capsule rupture. One hundred twenty porcine eyes were used for experiments within a setting of typical human physiological intraocular pressure. We found that Group-M showed capsule rupture with a smaller ultrasound power than did Group-P, regardless of power mode or aspiration power. In Group-M, there was no significant difference in risk of capsule rupture among power modes, however in Group-P, capsule rupture was least likely to occur with Mode-T. These results provide useful information for inexperienced ophthalmologists to improve surgical safety.
Collapse
Affiliation(s)
- Kei Ichikawa
- Chukyo Eye Clinic, Nagoya, Aichi, Japan
- General Aoyama Hospital, Toyokawa, Aichi, Japan
| | | | | | | | | | | | | | - Naoki Yamamoto
- Support Office for Bioresource Research, Center for Translational Research, Translational Research Headquarters, Fujita Health University, Toyoake, Aichi, Japan
- International Center for Cell and Gene Therapy, Research Promotion Headquarters, Fujita Health University, Toyoake, Aichi, Japan
| |
Collapse
|
2
|
Wilkinson SW, Ungricht EL, West WB, Harris JT, Zaugg B, Olson RJ, Pettey JH. Comparison of Phacoemulsification Grooving Efficiency in Longitudinal vs Transversal Handpieces. Clin Ophthalmol 2023; 17:191-195. [PMID: 36660311 PMCID: PMC9844818 DOI: 10.2147/opth.s391928] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2022] [Accepted: 11/29/2022] [Indexed: 01/12/2023] Open
Abstract
Purpose To determine the difference, if any, in grooving efficiency at various settings on the Whitestar Signature Pro phacoemulsification (phaco) system. Methods Cataractous lenses were simulated by exposing porcine lenses to formalin for 2 hours. A total of 120 lenses were analyzed at various power settings on both longitudinal and transversal handpieces. Twenty trials each were performed with power set to 25%, 50%, and 75% on both handpieces. A Whitestar Phaco Handpiece System was used to provide longitudinal power, and a Whitestar Signature Ellipsis Handpiece provided transversal power. Lenses were placed within a plastic chamber and grooved by an investigator blinded to settings. A second investigator recorded times and adjusted settings. The Whitestar Signature Pro phaco system was used for grooving. Results There was no significant difference in grooving times between the longitudinal and transverse handpieces at any power setting (P > 0.05). There was a significant decrease in grooving times when comparing the 25% power setting with the 75% power setting for the transversal handpiece (P=0.021). Conclusion Both longitudinal and transversal handpieces on the Whitestar Signature Pro phaco system produce similar results to one another at each power setting. There is a general trend toward shorter grooving times, reflecting greater efficiency, at higher power settings. Grooving efficiency on the transversal handpiece may be more affected by changes in the power settings as compared with the longitudinal settings.
Collapse
Affiliation(s)
- Samuel W Wilkinson
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, USA
| | - Emilie L Ungricht
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, USA,University of Utah School of Medicine, Salt Lake City, UT, USA
| | - William B West
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, USA,University of Utah School of Medicine, Salt Lake City, UT, USA
| | - Jacob T Harris
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, USA,University of Utah School of Medicine, Salt Lake City, UT, USA
| | - Brian Zaugg
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, USA
| | - Randall J Olson
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, USA
| | - Jeff H Pettey
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, USA,Correspondence: Jeff H Pettey, John A. Moran Eye Center, University of Utah, 65 Mario Capecchi Drive, Salt Lake City, UT, 84132, USA, Tel +1 801-581-2352, Fax +1 801-581-3357, Email
| |
Collapse
|
3
|
Peterson JS, Cooper C, Ungricht EL, Mamalis C, Barlow W, Zaugg B, Bernhisel AA, Olson RJ, Pettey JH. Measurement of Phacoemulsification Vacuum Pressure in the Oertli CataRhex3. Clin Ophthalmol 2022; 16:1731-1737. [PMID: 35673346 PMCID: PMC9167595 DOI: 10.2147/opth.s356657] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Accepted: 04/20/2022] [Indexed: 12/04/2022] Open
Abstract
Purpose To determine the actual vacuum pressure generated by the Oertli CataRhex 3® (Oertli), using an external measuring system. Methods The effective vacuum pressure created by the Oertli was measured with a pressure device that was continuous with the vacuum tubing system while closed to the external environment. Measurements were taken with the machine set to 300 and 500 mmHg at flow rates of 20, 35, and 50 mL/min and at bottle heights of 60, 80, and 100 cm. Pressures were recorded after the foot pedal was depressed to vacuum setting (second position), and the pressure was allowed to stabilize. Subsequently, it was compared to the pressure value displayed by the machine. Results Externally measured vacuum pressure was on average 13.02% greater (39.05 mmHg) than displayed vacuum pressure at 300 mmHg (P < 0.005) and 8.60% greater (42.98 mmHg) than displayed vacuum at 500 mmHg (P < 0.005). The average difference between displayed and measured pressure increased with increasing bottle heights. Conclusion On average, the vacuum pressure generated in the Oertli was found to be significantly higher than the machine’s reading when the machine was set at 300 mmHg and 500 mmHg. Adjusting vacuum had variable effects on the measured versus displayed pressure readings.
Collapse
Affiliation(s)
- John S Peterson
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
- University of Utah School of Medicine, Salt Lake City, UT, 84132, USA
| | - Caitlynn Cooper
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
- University of Utah School of Medicine, Salt Lake City, UT, 84132, USA
| | - Emilie L Ungricht
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
- University of Utah School of Medicine, Salt Lake City, UT, 84132, USA
| | - Christina Mamalis
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
| | - William Barlow
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
| | - Brian Zaugg
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
| | - Ashlie A Bernhisel
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
| | - Randall J Olson
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
| | - Jeff H Pettey
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
- Correspondence: Jeff H Pettey, Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, 65 Mario Capecchi Drive, Salt Lake City, UT, 84132, USA, Tel +1 801 581 2352, Fax +1 801 581 3357, Email
| |
Collapse
|
4
|
Peterson JS, Christensen MR, Cooper C, Mamalis C, Bernhisel AA, Zaugg B, Barlow WR, Ungricht E, Olson RJ, Pettey JH. Optimization of Phacoemulsification Tip Gauge on the Oertli CataRhex3 in an in vitro Setting. Clin Ophthalmol 2022; 16:1091-1097. [PMID: 35422610 PMCID: PMC9005135 DOI: 10.2147/opth.s355094] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Accepted: 03/17/2022] [Indexed: 11/23/2022] Open
Abstract
Purpose To evaluate the effect of each of the tip sizes available for the Oertli CataRhex3® phacoemulsification machine on efficiency. Methods Porcine lenses were fixed in formalin for 2 hours, then cut into 3.0 mm cubes. We studied three Oertli tips, all of which had a 30-degree bevel: easyTip 2.2 mm (20G), easyTip 2.8 mm (19G), and CO-MICS (21G). For the 19G and 20G tips, vacuum was set at 600 mmHg, irrigation rate at 50 mL/min, continuous power 70%, and bottle height 85 cm. For the 21G tip, vacuum was set at 450 mmHg; irrigation and power settings were identical to those used for the easyTip tips. We measured time to removal and chatter events to determine efficiency. Results Results from 20 trials for each tip showed that the larger the gauge size, the more quickly lens fragments were removed. Chatter events demonstrated an increasing trend with smaller tip gauge. The 19G tip used an average time to fragment removal of 2.8 seconds; the 20G, 3.2 seconds; and the 21G, 4.6 seconds. Increasing tip diameter from 21G to 20G decreased emulsification time by 33% (P = 0.02). Increasing the diameter from 21G to 19G further decreased time to emulsification by 42% (P = 0.003). The 21G tip had a mean 1.4 events/cube; 20G, 0.35 events; and 19G, 0.1 events. Differences in mean chatter events for each tip were each statistically significant. Conclusion These data suggest that when evaluated by chatter events and emulsification time, the 2.8 mm (19G) easyTip proves to have greatest efficiency.
Collapse
Affiliation(s)
- John S Peterson
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
- University of Utah School of Medicine, Salt Lake City, UT, 84132, USA
| | - Michael R Christensen
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
- Medical College of Virginia/Virginia Commonwealth University School of Medicine, Richmond, VA, 23298, USA
| | - Caitlynn Cooper
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
- University of Utah School of Medicine, Salt Lake City, UT, 84132, USA
| | - Christina Mamalis
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
| | - Ashlie A Bernhisel
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
| | - Brian Zaugg
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
| | - William R Barlow
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
| | - Emilie Ungricht
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
- University of Utah School of Medicine, Salt Lake City, UT, 84132, USA
| | - Randall J Olson
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
| | - Jeff H Pettey
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
- Correspondence: Jeff H Pettey, Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, 65 Mario Capecchi Drive, Salt Lake City, UT, 84132, USA, Tel +1 801 581 2352, Fax +1 801 581 3357, Email
| |
Collapse
|
5
|
Ramshekar A, Heczko J, Bernhisel A, Barlow W, Zaugg B, Olson R, Pettey J. Optimizing Tip Diameter in Phacoemulsification of Varying Lens Sizes: An in vitro Study. Clin Ophthalmol 2021; 15:4475-4484. [PMID: 34819719 PMCID: PMC8607188 DOI: 10.2147/opth.s333903] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Accepted: 10/11/2021] [Indexed: 11/23/2022] Open
Abstract
Purpose We assessed the effect of two lens cube sizes, three tip sizes, and two ultrasound (US) approaches on phacoemulsification efficiency and chatter. Methods After porcine lens nuclei were soaked in formalin, we divided them into cubes measuring 2.0 mm or 3.0 mm. We collected efficiency and chatter data for 30-degree bent 19 G, 20 G, and 21 G tips with a continuous torsional US system; and for straight 19 G, 20 G, and 21 G tips with a micropulse longitudinal US system. Results The average time needed for removal was always higher for the 3.0 mm lens cube than for the 2.0 mm lens cube. Statistically significant differences were observed between the 19 G and 21 G tips with micropulse longitudinal US using a 2.0 mm cube and a 3.0 mm cube, and with continuous transversal US using a 2.0 mm lens cube and a 3.0 mm cube. We did not observe significant differences between 19 G and 20 G tips with either cube size in either US system. However, we noted identical trends for both cube sizes with both US approaches; 19 G tips performed better than 20 G and 21 G tips. Conclusion Regardless of the lens size, 19 G needles were the most efficient, and had both the fewest outliers and the smallest standard deviations.
Collapse
Affiliation(s)
- Aniket Ramshekar
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA.,University of Utah School of Medicine, Salt Lake City, UT, 84132, USA
| | - Joshua Heczko
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
| | - Ashlie Bernhisel
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
| | - William Barlow
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
| | - Brian Zaugg
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
| | - Randall Olson
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
| | - Jeff Pettey
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT, 84132, USA
| |
Collapse
|
6
|
Bernhisel AA, Cahoon JM, Sella R, Zaugg B, Barlow WR, Stagg BC, Afshari NA, Olson RJ, Pettey JH. Optimum on-time and off-time combinations for micropulse phacoemulsification in venturi vacuum mode. J Cataract Refract Surg 2019; 45:1797-1800. [PMID: 31856992 DOI: 10.1016/j.jcrs.2019.07.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2019] [Revised: 06/28/2019] [Accepted: 07/01/2019] [Indexed: 11/26/2022]
Abstract
PURPOSE To measure the time to fragment removal and number of chatter events using various combinations of micropulse on times and off times (measured in milliseconds) of longitudinal ultrasound (US) using a venturi-based phacoemulsification system. SETTING John A. Moran Eye Center, University of Utah, Salt Lake City, USA. DESIGN Experimental study. METHODS Pig lenses were hardened with formalin and cut into 2.0 mm cubes. The time to fragment removal (efficiency) and frequency of fragments bouncing off the tip (chatter) were measured with the venturi-based system. Micropulse longitudinal US was tested. Parameters were combinations of 5, 6, and 7 milliseconds on, with 5, 6, and 7 milliseconds off. Twenty runs each of 9 combinations were completed. RESULTS There was a statistically significant difference between on/off duty cycle combinations. The 6 on/7 off group had higher efficiency than the 5 on/6 off and 7 on/7 off groups. Six on/5 off was more efficient than 5 on/6 off. When data were pooled and on times alone were used, 6 milliseconds on time was more efficient than 5 or 7 milliseconds. No efficiency differences in off times were found. No significant chatter differences were observed. CONCLUSIONS Using micropulse longitudinal US in venturi vacuum mode, 6 milliseconds on was the most efficient on time. Five, 6, and 7 milliseconds off times had similar efficiency. These data suggest that the most efficient setting with lowest US energy use is 6 milliseconds on and 7 milliseconds off.
Collapse
Affiliation(s)
- Ashlie A Bernhisel
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, USA; Department of Ophthalmology, Shiley Eye Institute at University of California San Diego Health, San Diego, USA
| | - Judd M Cahoon
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, USA; Stein Eye Institute, University of California Los Angeles, USA
| | - Ruti Sella
- Department of Ophthalmology, Shiley Eye Institute at University of California San Diego Health, San Diego, USA
| | - Brian Zaugg
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, USA
| | - William R Barlow
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, USA
| | - Brian C Stagg
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, USA; Duke Eye Center and Department of Ophthalmology, Duke University, Durham, North Carolina, USA
| | - Natalie A Afshari
- Department of Ophthalmology, Shiley Eye Institute at University of California San Diego Health, San Diego, USA
| | - Randall J Olson
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, USA
| | - Jeff H Pettey
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, USA.
| |
Collapse
|
7
|
Kabbara SW, Heczko J, Ta B, Bernhisel A, Barlow W, Zaugg B, Olson RJ, Pettey J. Impact of torsional micropulse on phacoemulsification efficiency and chatter. Can J Ophthalmol 2019; 54:560-564. [PMID: 31564345 DOI: 10.1016/j.jcjo.2019.02.016] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2018] [Revised: 01/31/2019] [Accepted: 02/05/2019] [Indexed: 11/25/2022]
Abstract
OBJECTIVE Evaluate the effect of increasing ultrasound (US) power on chatter events and efficiency under both continuous and micropulse torsional US to reduce total cataract extraction times. DESIGN In vitro laboratory study. METHODS Porcine lens nuclei were incubated in formalin for 2 hours and then cut into 2-mm cubes. Phacoemulsification was performed using the Centurion Vision System and Infiniti OZil handpiece with the balanced tip. Both US modalities were studied at 60%, 80%, and 100% power. Micropulse rate was 83 pulses per second with 50% on time. Each combination comprised 20 runs. Efficiency was considered as the total time for a cube to be emulsified; chatter was the number of times the lens fragment bounced off the tip. RESULTS There was significant decrease in efficiency when power was increased from 60% to 100% (1.33-1.97 s; p < 0.001) under micropulse US and significant increase in chatter when power was further increased to 100% from 60% (0.15-0.94 s; p < 0.001). There was no significant efficiency change with increased power under continuous US. Comparing the phacoemulsification efficiency between continuous and micropulse US, we found no significant difference at 60% and 80% power; at 100% power, continuous was significantly more efficient than micropulse (1.48 and 1.97 s, respectively; p = 0.001). CONCLUSIONS Increasing power above 60% decreased efficiency under torsional micropulse US. We believe that this was due to the chatter increase observed with increasing US power. Torsional continuous US was significantly more efficient than micropulse US at 100% power.
Collapse
Affiliation(s)
- Sami W Kabbara
- Banner-University of Arizona College of Medicine, Phoenix, AZ
| | - Joshua Heczko
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT
| | - Brian Ta
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT
| | - Ashlie Bernhisel
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT
| | - William Barlow
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT
| | - Brian Zaugg
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT
| | - Randall J Olson
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT
| | - Jeff Pettey
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT.
| |
Collapse
|
8
|
Boulter T, Bernhisel A, Mamalis C, Zaugg B, Barlow WR, Olson RJ, Pettey JH. Phacoemulsification in review: Optimization of cataract removal in an in vitro setting. Surv Ophthalmol 2019; 64:868-875. [PMID: 31276738 DOI: 10.1016/j.survophthal.2019.06.007] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2019] [Revised: 06/17/2019] [Accepted: 06/17/2019] [Indexed: 10/26/2022]
Abstract
Phacoemulsification, initially used in the late 1960s, continues to be the standard of care for cataract removal. An animal model was developed so that, in a controlled research setting, all the various machines, handpieces, tips, and settings could be investigated. As a general rule, the higher power, vacuum, and aspiration settings lead to optimally efficient phacoemulsification. In addition, both new phacoemulsification platforms and newly developed devices have been shown to improve efficiency. As a result, we recommend that the integration of these recent developments should be considered in future investigations.
Collapse
Affiliation(s)
- Tyler Boulter
- Department of Ophthalmology and Visual Sciences, University of Wisconsin, Madison, Wisconsin, USA
| | - Ashlie Bernhisel
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA; Department of Ophthalmology, Shiley Eye Institute at University of California San Diego Health, San Diego, California, USA
| | - Christina Mamalis
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Brian Zaugg
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - William R Barlow
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Randall J Olson
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Jeff H Pettey
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA.
| |
Collapse
|
9
|
Kabbara SW, Heczko J, Ta B, Bernhisel A, Barlow W, Zaugg B, Olson RJ, Pettey J. Determining optimal ultrasound percent on time with long-pulse torsional phacoemulsification. Can J Ophthalmol 2019; 54:395-398. [PMID: 31109482 DOI: 10.1016/j.jcjo.2018.07.005] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2018] [Revised: 07/06/2018] [Accepted: 07/13/2018] [Indexed: 11/15/2022]
Abstract
OBJECTIVE To evaluate the optimum percent on time for the most efficient lens fragment removal using long-pulse torsional ultrasound (US). DESIGN In vitro laboratory study. METHODS Porcine lens nuclei were incubated in formalin for 2 hours and then cut into 2 mm cubes. Phacoemulsification was performed using the Centurion® Vision System and Infiniti OZil handpiece with the balanced tip. Vacuum was set at 500 mm Hg, aspiration rate at 50 mL/min, and intraocular pressure (IOP) at 50 mm Hg. Pulse rate was 26 pulses/second. Studied parameters were percent power: 60%, 80%, and 100%, and percent on times: 50%, 60%, 70%, and 80%. Efficiency was the total time for a cube to be emulsified. Chatter was the number of times the lens fragment bounced off the tip. RESULTS There was no significant difference in efficiency between 50%, 60%, and 70 % on-time settings (p = 0.17 and 0.08, respectively); however, there was significant increase in efficiency when the on time was increased from 70% to 80% (p = 0.03). Increasing power from 60% to 100% showed a statistically significant efficiency increase (p = 0.001). There was no significant change in chatter with increasing on time; however, there was a statistically significant increase in chatter with every power level increase. CONCLUSION Increasing on-time percent does not improve efficiency under torsional long-pulse US. There is no significant change in chatter with increasing on-time percent. Increasing power increases efficiency despite chatter increase. Long-pulse US does not appear to influence torsional action in a clinically meaningful way.
Collapse
Affiliation(s)
| | - Joshua Heczko
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT
| | - Brian Ta
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT
| | - Ashlie Bernhisel
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT
| | - William Barlow
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT
| | - Brian Zaugg
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT
| | - Randall J Olson
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT
| | - Jeff Pettey
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, UT..
| |
Collapse
|
10
|
Thomson RS, Bird BA, Stutz LA, Heczko JB, Bernhisel AA, Barlow WR, Zaugg B, Olson RJ, Pettey JH. The effect of increasing power when grooving using phacoemulsification. Clin Ophthalmol 2019; 13:611-615. [PMID: 31043766 PMCID: PMC6469737 DOI: 10.2147/opth.s194731] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
PURPOSE To determine optimal power settings on the Centurion Vision System during the grooving step in cataract surgery. METHODS Intact porcine lenses hardened by formalin and placed in a chamber designed to simulate the anterior chamber of the eye were used to test longitudinal power at 40%, 70%, and 100% and torsional power at 0%. Flow rate was set at 40 mL/min. Vacuum was set at 400 mmHg, intraocular pressure was set at 50 mmHg, and a balanced phacoemulsification tip with a 20 degree tip and a 30 degree bevel was used. Efficiency (time to groove the lens in half) was determined. RESULTS Increasing longitudinal power from 40% to 70% increased efficiency by 28% (P<0.05), and by 32% (P<0.05) when increasing longitudinal power from 40% to 100%. There was no statistically significant increase in efficiency from 70% to 100%. CONCLUSION For the tested variables, a longitudinal power of 70% was determined to be most efficient during the grooving step of cataract surgery for equivalent 3-4+ nuclei. Further increases in power demonstrated no statistically significant improvement in efficiency.
Collapse
Affiliation(s)
- Rhett S Thomson
- Department of Ophthalmology and Visual Sciences, John A Moran Eye Center, University of Utah, Salt Lake City, UT 84132, USA,
- University of Utah School of Medicine, Salt Lake City, UT 84132, USA
| | - Brian A Bird
- University of Nevada Reno School of Medicine, Reno, NV 89557, USA
| | - Lance A Stutz
- University of Texas Southwestern Medical School, Dallas, TX 75390, USA
| | - Joshua B Heczko
- Department of Ophthalmology and Visual Sciences, John A Moran Eye Center, University of Utah, Salt Lake City, UT 84132, USA,
| | - Ashlie A Bernhisel
- Department of Ophthalmology and Visual Sciences, John A Moran Eye Center, University of Utah, Salt Lake City, UT 84132, USA,
| | - William R Barlow
- Department of Ophthalmology and Visual Sciences, John A Moran Eye Center, University of Utah, Salt Lake City, UT 84132, USA,
| | - Brian Zaugg
- Department of Ophthalmology and Visual Sciences, John A Moran Eye Center, University of Utah, Salt Lake City, UT 84132, USA,
| | - Randall J Olson
- Department of Ophthalmology and Visual Sciences, John A Moran Eye Center, University of Utah, Salt Lake City, UT 84132, USA,
| | - Jeff H Pettey
- Department of Ophthalmology and Visual Sciences, John A Moran Eye Center, University of Utah, Salt Lake City, UT 84132, USA,
| |
Collapse
|
11
|
Kabbara S, Heczko JB, Bernhisel AA, Barlow WR, Zaugg B, Pettey JH, Olson RJ. Effect of high vacuum and aspiration on phacoemulsification efficiency and chatter using a transversal ultrasound machine. J Cataract Refract Surg 2018; 44:1378-1383. [PMID: 30201130 DOI: 10.1016/j.jcrs.2018.05.031] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2017] [Revised: 03/22/2018] [Accepted: 05/29/2018] [Indexed: 11/26/2022]
Abstract
PURPOSE To examine the role of high vacuum and aspiration settings on efficiency using a transversal ultrasound (US) machine. SETTING John A. Moran Eye Center Laboratory, University of Utah, Salt Lake City, Utah, USA. DESIGN Experimental study. METHODS Porcine lens nuclei were incubated in formalin for 2 hours and then cut into 2.0 mm cubes. Phacoemulsification was performed using the Whitestar Signature machine. Settings were bottle height 50 cm, on-time 6 milliseconds, and off-time 6 milliseconds. One hundred percent power was used for all 240 runs. Tested parameters were aspiration of 50 mL/min and 60 mL/min and vacuum of 500, mm Hg, 600 mm Hg, and 650 mm Hg. RESULTS With continuous US, increasing aspiration from 50 mL/min to 60 mL/min significantly increased efficiency (23%). Increasing vacuum from 500 mm Hg to 650 mm Hg and from 600 mm Hg to 650 mm Hg significantly increased efficiency (20.2% and 13.6%, respectively). Higher vacuum and aspiration parameters did not influence the incidence of chatter events. In the micropulse US group, there was no significant efficiency increase with increasing vacuum or aspiration levels. There was a significant efficiency increase of continuous over micropulse US at an aspiration setting of 60 mL/min and vacuum settings of 600 mm Hg and 650 mm Hg. CONCLUSIONS As aspiration and vacuum increased, efficiency increased under continuous transverse US. No significant efficiency improvement occurred at high aspiration and vacuum settings under micropulse US. At 60 mL/min aspiration and more than 600 mm Hg vacuum, continuous power was significantly more efficient than micropulse transverse US.
Collapse
Affiliation(s)
- Sami Kabbara
- From the University of Arizona College of Medicine-Phoenix (Kabbara), Phoenix, Arizona, and the Department of Ophthalmology and Visual Sciences (Heczko, Bernhisel, Barlow, Zaugg, Pettey, Olson), John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Joshua B Heczko
- From the University of Arizona College of Medicine-Phoenix (Kabbara), Phoenix, Arizona, and the Department of Ophthalmology and Visual Sciences (Heczko, Bernhisel, Barlow, Zaugg, Pettey, Olson), John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Ashlie A Bernhisel
- From the University of Arizona College of Medicine-Phoenix (Kabbara), Phoenix, Arizona, and the Department of Ophthalmology and Visual Sciences (Heczko, Bernhisel, Barlow, Zaugg, Pettey, Olson), John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - William R Barlow
- From the University of Arizona College of Medicine-Phoenix (Kabbara), Phoenix, Arizona, and the Department of Ophthalmology and Visual Sciences (Heczko, Bernhisel, Barlow, Zaugg, Pettey, Olson), John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Brian Zaugg
- From the University of Arizona College of Medicine-Phoenix (Kabbara), Phoenix, Arizona, and the Department of Ophthalmology and Visual Sciences (Heczko, Bernhisel, Barlow, Zaugg, Pettey, Olson), John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Jeff H Pettey
- From the University of Arizona College of Medicine-Phoenix (Kabbara), Phoenix, Arizona, and the Department of Ophthalmology and Visual Sciences (Heczko, Bernhisel, Barlow, Zaugg, Pettey, Olson), John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Randall J Olson
- From the University of Arizona College of Medicine-Phoenix (Kabbara), Phoenix, Arizona, and the Department of Ophthalmology and Visual Sciences (Heczko, Bernhisel, Barlow, Zaugg, Pettey, Olson), John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA.
| |
Collapse
|
12
|
Bird BA, Thomson RS, Stutz LA, Heczko JB, Bernhisel AA, Barlow WR, Zaugg B, Pettey JH, Olson RJ. Effect of increasing flow when grooving during phacoemulsification. J Cataract Refract Surg 2018; 44:623-626. [PMID: 29773457 DOI: 10.1016/j.jcrs.2018.01.034] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2017] [Revised: 12/22/2017] [Accepted: 01/09/2018] [Indexed: 11/17/2022]
Abstract
PURPOSE To determine optimum flow settings on the Centurion Vision System during the grooving step in cataract surgery. SETTING John A. Moran Eye Center Laboratory, University of Utah, Salt Lake City, Utah, USA. DESIGN Experimental study. METHODS Intact porcine lenses hardened by formalin and placed in a chamber designed to simulate the anterior chamber of the eye were used to test flow rate settings at 20 mL/min, 40 mL/min, and 60 mL/min. Vacuum was set at 400 mm Hg, longitudinal power at 80%, torsional power at 80%, and intraocular pressure at 50 mm Hg. A balanced phaco tip with a 20-degree tip and a 30-degree bevel was used. Efficiency (time to groove the lens in half) was determined. RESULTS Increasing flow from 20 to 40 mL/min during grooving increased efficiency by 17% (P = .05), with no significant improvement shown at 60 mL/min. CONCLUSIONS A flow rate of 40 mL/min was determined to be most efficient during the grooving step of cataract surgery. Further increases in flow rate showed no statistically significant improvement in efficiency, and with only 17% improvement flow rates less than 40 mL/min might be almost as efficient and might be safer.
Collapse
Affiliation(s)
- Brian A Bird
- From the University of Nevada Reno School of Medicine (Bird), Reno, Nevada, Department of Ophthalmology and Visual Sciences (Thomson, Heczko, Bernhisel, Barlow, Zaugg, Pettey, Olson), John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, and the University of Texas Southwestern Medical Center (Stutz), Dallas, Texas, USA
| | - Rhett S Thomson
- From the University of Nevada Reno School of Medicine (Bird), Reno, Nevada, Department of Ophthalmology and Visual Sciences (Thomson, Heczko, Bernhisel, Barlow, Zaugg, Pettey, Olson), John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, and the University of Texas Southwestern Medical Center (Stutz), Dallas, Texas, USA
| | - Lance A Stutz
- From the University of Nevada Reno School of Medicine (Bird), Reno, Nevada, Department of Ophthalmology and Visual Sciences (Thomson, Heczko, Bernhisel, Barlow, Zaugg, Pettey, Olson), John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, and the University of Texas Southwestern Medical Center (Stutz), Dallas, Texas, USA
| | - Joshua B Heczko
- From the University of Nevada Reno School of Medicine (Bird), Reno, Nevada, Department of Ophthalmology and Visual Sciences (Thomson, Heczko, Bernhisel, Barlow, Zaugg, Pettey, Olson), John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, and the University of Texas Southwestern Medical Center (Stutz), Dallas, Texas, USA
| | - Ashlie A Bernhisel
- From the University of Nevada Reno School of Medicine (Bird), Reno, Nevada, Department of Ophthalmology and Visual Sciences (Thomson, Heczko, Bernhisel, Barlow, Zaugg, Pettey, Olson), John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, and the University of Texas Southwestern Medical Center (Stutz), Dallas, Texas, USA
| | - William R Barlow
- From the University of Nevada Reno School of Medicine (Bird), Reno, Nevada, Department of Ophthalmology and Visual Sciences (Thomson, Heczko, Bernhisel, Barlow, Zaugg, Pettey, Olson), John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, and the University of Texas Southwestern Medical Center (Stutz), Dallas, Texas, USA
| | - Brian Zaugg
- From the University of Nevada Reno School of Medicine (Bird), Reno, Nevada, Department of Ophthalmology and Visual Sciences (Thomson, Heczko, Bernhisel, Barlow, Zaugg, Pettey, Olson), John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, and the University of Texas Southwestern Medical Center (Stutz), Dallas, Texas, USA
| | - Jeff H Pettey
- From the University of Nevada Reno School of Medicine (Bird), Reno, Nevada, Department of Ophthalmology and Visual Sciences (Thomson, Heczko, Bernhisel, Barlow, Zaugg, Pettey, Olson), John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, and the University of Texas Southwestern Medical Center (Stutz), Dallas, Texas, USA
| | - Randall J Olson
- From the University of Nevada Reno School of Medicine (Bird), Reno, Nevada, Department of Ophthalmology and Visual Sciences (Thomson, Heczko, Bernhisel, Barlow, Zaugg, Pettey, Olson), John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, and the University of Texas Southwestern Medical Center (Stutz), Dallas, Texas, USA.
| |
Collapse
|
13
|
Wright AJ, Thomson RS, Bernhisel AA, Zaugg B, Barlow WR, Pettey JH, Olson RJ. Effect of chamber stabilization software on efficiency and chatter in a porcine lens model. J Cataract Refract Surg 2017; 43:1464-1467. [PMID: 29223237 DOI: 10.1016/j.jcrs.2017.08.018] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2017] [Revised: 07/30/2017] [Accepted: 08/04/2017] [Indexed: 11/26/2022]
Abstract
PURPOSE To evaluate the effects of the use of programmable chamber stabilization software (Chamber Stabilization Environment) settings on efficiency and chatter in a porcine lens model. SETTING John A. Moran Eye Center Laboratory, University of Utah, Salt Lake City, Utah, USA. DESIGN Experimental study. METHODS Porcine eyes were dissected and the lenses extracted. The lenses were then hardened and processed for the experiment. Phacoemulsification of the lens fragments was performed with the Whitestar Signature Pro with the Whitestar handpiece and a 0.9 mm straight Dewey tip with a 30-degree bevel. All arms of the study were run in peristaltic mode with 50 mL/minute aspiration, 100 cm bottle height, and on 100% power. The chamber stabilization software setting was used for each of the 4 study arms with a maximum vacuum of 500 mm Hg. Arm 1 included 20 runs with the up time set to 2000 milliseconds. Arm 2 was performed with similar settings but with an up time of 0 millisecond. Arms 3 and 4 were run with up times of 1000 milliseconds and 500 milliseconds, respectively. RESULTS The mean efficiency time of each run was as follows: 0 millisecond = 1.4 seconds, 500 milliseconds = 0.95 seconds, 1000 milliseconds = 0.88 seconds, 2000 milliseconds = 0.93 seconds. When compared with 0 millisecond, each of the other arms were significantly faster. Chatter events were comparable between the study arms. CONCLUSION The chamber stabilization software does not decrease efficiency when compared with full vacuum on if at least 500 milliseconds of up time is maintained.
Collapse
Affiliation(s)
- Alex J Wright
- From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Rhett S Thomson
- From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Ashlie A Bernhisel
- From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Brian Zaugg
- From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - William R Barlow
- From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Jeff H Pettey
- From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Randall J Olson
- From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA.
| |
Collapse
|
14
|
Optimization and comparison of a 0.7 mm tip with the 0.9 mm tip on an active-fluidics phacoemulsification platform. J Cataract Refract Surg 2017; 43:1591-1595. [DOI: 10.1016/j.jcrs.2017.08.022] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2017] [Revised: 07/27/2017] [Accepted: 08/04/2017] [Indexed: 11/13/2022]
|
15
|
Shi DS, Jensen JD, Kramer GD, Zaugg B, Stagg BC, Pettey JH, Barlow WR, Olson RJ. Comparison of Vacuum and Aspiration on Phacoemulsification Efficiency and Chatter Using a Monitored Forced Infusion System. Am J Ophthalmol 2016; 169:162-167. [PMID: 27349412 DOI: 10.1016/j.ajo.2016.06.030] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2016] [Revised: 06/15/2016] [Accepted: 06/16/2016] [Indexed: 11/28/2022]
Abstract
PURPOSE To evaluate the effect of vacuum and aspiration rates on phacoemulsification efficiency and chatter using a monitored forced infusion system. DESIGN In vitro animal study. METHODS SETTING John A. Moran Eye Center, University of Utah, Salt Lake City, Utah. PROCEDURES Formalin-soaked porcine lenses were divided into 2 mm cubes (tip diameter, 0.9 mm). Vacuum levels were tested at 200, 300, 400, and 500 mm Hg; aspiration rates at 20, 35, and 50 mL/min. Torsional power was set at 60% and intraocular pressure at 50 mm Hg. RESULTS Increasing vacuum increased efficiency regardless of aspiration rates (R(2) = 0.92; P = .0004). Increasing aspiration further increased efficiency when vacuum was at 400 and 500 mm Hg (P = .004 for 20 vs 35 mL/min, P = .0008 for 35 vs 50 mL/min). At 200 and 300 mm Hg, efficiency only improved when increasing aspiration to 35 mL/min (P < .0001 with 20 vs 35 + 50 mL/min). Chatter improved with increasing vacuum, up to 400 mm Hg (P = .003 for 200 vs 300 mm Hg and P = .045 for 300 vs 500 mm Hg). A similar trend of improved chatter was seen with increasing levels of aspiration. CONCLUSIONS Vacuum improved efficiency up to 500 mm Hg independent of flow. Flow has an additive effect on efficiency through 50 mL/min, when vacuum is at 400 mm Hg or higher, and only up to 35 mL/min at vacuums less than 400 mm Hg. Chatter correlated with both vacuum and flow such that increasing either parameter decreases chatter, up to 400 mm Hg with vacuum.
Collapse
Affiliation(s)
- Dallas S Shi
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah
| | - Jason D Jensen
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah
| | - Gregory D Kramer
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah
| | - Brian Zaugg
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah
| | - Brian C Stagg
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah
| | - Jeff H Pettey
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah
| | - William R Barlow
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah
| | - Randall J Olson
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah.
| |
Collapse
|
16
|
Yoo A, Nam KY, Tchah H, Kim MJ. Heat Generation and Efficiency of a New Modified Phaco Tip and Sleeve. PLoS One 2016; 11:e0159049. [PMID: 27487206 PMCID: PMC4972308 DOI: 10.1371/journal.pone.0159049] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2015] [Accepted: 06/27/2016] [Indexed: 11/19/2022] Open
Abstract
PURPOSE To compare a modified phacoemulsification tip with the established micro tip, in terms of temperature at the corneal wound, efficiency, and chatter events, using the Centurion® Vision system. METHODS Eighty porcine eyes were randomized into 4 groups: 1)sleeveless conventional 45D MiniFlared ABS® Kelman tip (1.1-mm incision); 2)sleeveless new modified 45D ABS® INTREPID® balanced tip(1.1-mm incision); 3) Kelman tip with own sleeve (2.2-mm incision); 4)Balanced tip with modified 4-rib sleeve (2.2-mm incision). Measurements were taken with 2 settings: longitudinal(power 40% and 70%) and torsional mode (power 40% and 100%). Peak temperatures were measured 0, 10, 30, and 60 seconds after continuous ultrasound power. For the efficiency test, porcine lens nuclei were formalin soaked and cut into 2.0 mm3 cubes. Efficiency and chatter were examined. RESULTS In all longitudinal settings, the sleeveless groups(1 and 2) showed lower temperatures than the sleeved groups(3 and 4) (P = 0.003). In 100% torsional mode, groups 3 and 4 produced significantly different temperatures(37.13 ± 1.44 and 35.14 ± 0.54, respectively; P = 0.007).The efficiency, in a 100% power torsional setting, was13.52 ± 2.60 sec for group 4, and 44.45± 14.75 sec for group 3 (P<0.001). CONCLUSIONS The two different bare tips show no significant differences in thermogenesis. However, the balanced tip with sleeve produces lower temperaturesat100% torsional power and better efficiency than the Kelman tip.
Collapse
Affiliation(s)
- Aeri Yoo
- Department of Ophthalmology, Saevit Eye Hospital, Goyang, Korea
| | - Ki Yeun Nam
- Department of Physical Medicine and Rehabilitation, Dongguk University College of Medicine, Goyang, Korea
| | - Hungwon Tchah
- Department of Ophthalmology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea
| | - Myoung Joon Kim
- Department of Ophthalmology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea
- * E-mail:
| |
Collapse
|
17
|
Jensen JD, Boulter T, Lambert NG, Zaugg B, Stagg BC, Pettey JH, Olson RJ. Intraocular pressure study using monitored forced-infusion system phacoemulsification technology. J Cataract Refract Surg 2016; 42:768-71. [DOI: 10.1016/j.jcrs.2016.01.045] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2015] [Revised: 01/14/2016] [Accepted: 01/26/2016] [Indexed: 10/21/2022]
|
18
|
Boulter T, Jensen JD, Christensen MD, Lambert NG, Zaugg B, Stagg BC, Pettey JH, Olson RJ. Comparison of a torsional and a standard tip with a monitored forced infusion phacoemulsification system. J Cataract Refract Surg 2016; 42:613-7. [PMID: 27113886 DOI: 10.1016/j.jcrs.2015.11.048] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2015] [Revised: 11/03/2015] [Accepted: 11/03/2015] [Indexed: 10/21/2022]
Abstract
PURPOSE To compare the relative efficiency and chatter of the 30-degree 0.9 mm Kelman tip (standard tip) and Ozil Intrepid Balanced tip (torsional tip) with identical optimum settings. SETTING John A. Moran Eye Center Laboratories, University of Utah, Salt Lake City, Utah, USA. DESIGN Experimental study. METHODS Porcine nuclei were fixed in formalin and cut into 2.0 mm cubes. Lens cubes were phacoemulsified with standard and torsional tips at 60% and 100% torsional amplitude with 0%, 25%, 50%, 75%, and 100% longitudinal power with monitored forced infusion. Experiments were performed at a constant vacuum, aspiration rate, and intraocular pressure. RESULTS Linear regression showed increased efficiency with up to 75% longitudinal power at 60% torsional amplitude for both tips (P = .046 standard; P = .0093 torsional). Longitudinal did not significantly increase efficiency at 100% torsional power for either tip. Torsional tips were on average 29% more efficient than standard tips throughout the range tested (P < .0001), and 100% torsional power was on average 45% more efficient than 60% torsional power (P = .0028). Chatter was minimal except at 100% longitudinal power, which was greater than at 75% longitudinal power (P < .0001). At 100% longitudinal power, torsional tips had more chatter than standard tips (at 60% torsional, P < .0001; at 100% torsional, P = .0022). CONCLUSIONS Increasing up to 75% longitudinal power increased the efficiency at 60% torsional for standard and torsional tips. Torsional tips were more efficient than standard tips. Chatter was generally minimal. Torsional tips showed more chatter than standard tips at 100% longitudinal power. FINANCIAL DISCLOSURE None of the authors has a financial or proprietary interest in any material or method mentioned.
Collapse
Affiliation(s)
- Tyler Boulter
- From the Department of Ophthalmology (Boulter), Texas A & M University, College Station, Texas, and the Department of Ophthalmology and Visual Sciences (Jensen, Christensen, Lambert, Zaugg, Stagg, Pettey, Olson), John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Jason D Jensen
- From the Department of Ophthalmology (Boulter), Texas A & M University, College Station, Texas, and the Department of Ophthalmology and Visual Sciences (Jensen, Christensen, Lambert, Zaugg, Stagg, Pettey, Olson), John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Michael D Christensen
- From the Department of Ophthalmology (Boulter), Texas A & M University, College Station, Texas, and the Department of Ophthalmology and Visual Sciences (Jensen, Christensen, Lambert, Zaugg, Stagg, Pettey, Olson), John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Nathan G Lambert
- From the Department of Ophthalmology (Boulter), Texas A & M University, College Station, Texas, and the Department of Ophthalmology and Visual Sciences (Jensen, Christensen, Lambert, Zaugg, Stagg, Pettey, Olson), John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Brian Zaugg
- From the Department of Ophthalmology (Boulter), Texas A & M University, College Station, Texas, and the Department of Ophthalmology and Visual Sciences (Jensen, Christensen, Lambert, Zaugg, Stagg, Pettey, Olson), John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Brian C Stagg
- From the Department of Ophthalmology (Boulter), Texas A & M University, College Station, Texas, and the Department of Ophthalmology and Visual Sciences (Jensen, Christensen, Lambert, Zaugg, Stagg, Pettey, Olson), John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Jeff H Pettey
- From the Department of Ophthalmology (Boulter), Texas A & M University, College Station, Texas, and the Department of Ophthalmology and Visual Sciences (Jensen, Christensen, Lambert, Zaugg, Stagg, Pettey, Olson), John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Randall J Olson
- From the Department of Ophthalmology (Boulter), Texas A & M University, College Station, Texas, and the Department of Ophthalmology and Visual Sciences (Jensen, Christensen, Lambert, Zaugg, Stagg, Pettey, Olson), John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA.
| |
Collapse
|
19
|
Jensen JD, Shi DS, Robinson MS, Kramer GD, Zaugg B, Stagg BC, Pettey JH, Barlow WR, Olson RJ. Torsional power study using CENTURION phacoemulsification technology. Clin Exp Ophthalmol 2016; 44:710-713. [PMID: 26999336 DOI: 10.1111/ceo.12748] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2015] [Revised: 02/24/2016] [Accepted: 03/14/2016] [Indexed: 11/28/2022]
Abstract
BACKGROUND To evaluate the effect of varying levels of power on phacoemulsification efficiency using the CENTURION Vision System. METHODS Formalin-soaked porcine lenses were divided into 2-mm cubes; 0.9-mm, balanced tips were used. Torsional power levels were tested from 10% to 100% at 10% intervals. Vacuum was set to 550 mmHg, aspiration to 50 ml/min, and intraocular pressure at 50 mmHg. Efficiency (time to lens removal) and chatter (number of lens fragment repulsions from the tip) were determined. RESULTS Increasing torsional power up to 60% increased efficiency. This effect was linear from 30 to 60% power (R2 = .90; P < 0.05). There were no significant differences in efficiency past 60%. Chatter was highest at 10% power and decreased linearly (R2 = .87; P = 0.007) as power was increased up to 60% power, and chatter did not improve above this power level. CONCLUSIONS Power improved efficiency only up to a 60% power level, and then was negligible. Chatter correlated well with power up to the 60% level, so that as power was increased, chatter decreased. Because there are no additional benefits in efficiency past 60% power, and because chatter is minimal at 60% power, we recommend torsional ultrasound at 60% as the optimal power setting for using the CENTURION System for phacoemulsification.l.
Collapse
Affiliation(s)
- Jason D Jensen
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Dallas S Shi
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Mark S Robinson
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Gregory D Kramer
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Brian Zaugg
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Brian C Stagg
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Jeff H Pettey
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - William R Barlow
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Randall J Olson
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| |
Collapse
|
20
|
Henriksen BS, Gardiner G, Garff K, Gupta I, Stagg BC, Zaugg B, Pettey JH, Barlow WR, Olson RJ. Thermal evaluation of two phacoemulsification systems. Can J Ophthalmol 2016; 51:14-8. [PMID: 26874153 DOI: 10.1016/j.jcjo.2015.10.013] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2015] [Revised: 10/09/2015] [Accepted: 10/28/2015] [Indexed: 12/01/2022]
Abstract
OBJECTIVE To compare thermal profiles of new transversal ultrasound power modulation to torsional ultrasound in an artificial chamber and cadaver eye. DESIGN Laboratory investigation. METHODS John A. Moran Eye Center Laboratories, University of Utah, Salt Lake City, Utah, was the study setting. Temperature increase after 30 seconds was measured at the needle midshaft in an artificial chamber and at maximal friction point in a cadaver eye. Ellips FX (transverse) was tested at 100% power, as was Signature with micropulse settings (6 milliseconds on and off). OZil (torsional only) was tested at 100% power in the artificial chamber and cadaver eye. Runs were completed with aspiration blocked. Temperature was continuously measured on the phacoemulsification sleeve using a microthermistor probe connected to the BAT-10 multipurpose thermometer, with an accuracy of ±0.1°C. RESULTS Transversal FX had a greater temperature increase than micropulse (p < 0.001) and torsional (p < 0.001). Micropulse had a greater temperature increase than torsional (p < 0.001). The cadaver eye had a greater temperature increase than the artificial chamber for torsional (p < 0.001). CONCLUSIONS Higher heat accumulation and potential for incisional burn occurred with the cadaver model than with the artificial chamber, suggesting the need for caution when using 100% torsional ultrasound with aspiration blocked. Transversal FX generated more heat than was reported originally. Further study is needed to determine the incidence of incisional burn with varied power settings for this new model. Micropulse generated more heat than previous reports, but the increased efficiency is likely to negate potentially increased incisional burn risk.
Collapse
Affiliation(s)
- Bradley S Henriksen
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah
| | - Gareth Gardiner
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah
| | - Kevin Garff
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah
| | - Isha Gupta
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah
| | - Brian C Stagg
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah
| | - Brian Zaugg
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah
| | - Jeff H Pettey
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah
| | - William R Barlow
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah
| | - Randall J Olson
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah.
| |
Collapse
|
21
|
Gardiner GL, Garff K, Gupta I, Kramer GD, Farukhi MA, Stagg BC, Zaugg B, Olson RJ. Effect of pulsing ultrasound on phacoemulsification efficiency. J Cataract Refract Surg 2015; 41:2560-4. [PMID: 26703507 DOI: 10.1016/j.jcrs.2015.06.030] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2015] [Revised: 06/02/2015] [Accepted: 06/08/2015] [Indexed: 10/22/2022]
Abstract
PURPOSE To evaluate pulse type technology used to remove lens fragments during phacoemulsification. SETTING John A. Moran Eye Center Laboratories, University of Utah, Salt Lake City, Utah, USA. DESIGN Experimental study. METHODS Lens nuclei soaked in 10 mL of 10% neutral buffered formalin for 2 hours were placed in 10 mL of balanced salt solution. Lenses were cut into 2 mm × 2 mm cubes; no more than 36 hours later, cubes were randomly selected for testing. Two aspiration and 2 vacuum settings were assessed at moderate- and high-flow and vacuum (30 mL/min and 300 mm/Hg, low-flow vacuum; 50 mL/min and 500 mm/Hg, high-flow vacuum), with continuous 50 milliseconds on and off (long pulse) and 6 milliseconds on and off (micropulse) ultrasound. RESULTS There was a significant difference in efficiency favoring micropulse compared with combined long pulse and continuous pulse in high-flow vacuum at 80% power (P = .018) and between combined long pulse and continuous pulse versus micropulse in high-flow vacuum at 20% power (P = .019). Low-flow vacuum micropulse was more efficient than continuous (19.7%) (P < .0001) and long pulse (22.7%) (P < .0001). Continuous and long pulses were not significantly different from one other. There was a significant difference in chatter rates between high-flow vacuum and low-flow vacuum when all results were compared (P < .0001), with no additional significant differences found. CONCLUSION Micropulse technology was better than continuous and long pulse at moderate but not high-flow and vacuum settings. At the higher setting, chatter was observed less often, with all modalities more efficient than the lower setting.
Collapse
Affiliation(s)
- Gareth L Gardiner
- From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Kevin Garff
- From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Isha Gupta
- From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Gregory D Kramer
- From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - M Aabid Farukhi
- From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Brian C Stagg
- From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Brian Zaugg
- From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA
| | - Randall J Olson
- From the Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA.
| |
Collapse
|
22
|
Davison JA. Two-speed phacoemulsification for soft cataracts using optimized parameters and procedure step toolbar with the CENTURION Vision System and Balanced Tip. Clin Ophthalmol 2015; 9:1563-72. [PMID: 26355695 PMCID: PMC4559244 DOI: 10.2147/opth.s90245] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Purpose To present a cause of posterior capsule aspiration and a technique using optimized parameters to prevent it from happening when operating soft cataracts. Patients and methods A prospective list of posterior capsule aspiration cases was kept over 4,062 consecutive cases operated with the Alcon CENTURION machine and Balanced Tip. Video analysis of one case of posterior capsule aspiration was accomplished. A surgical technique was developed using empirically derived machine parameters and customized setting-selection procedure step toolbar to reduce the pace of aspiration of soft nuclear quadrants in order to prevent capsule aspiration. Results Two cases out of 3,238 experienced posterior capsule aspiration before use of the soft quadrant technique. Video analysis showed an attractive vortex effect with capsule aspiration occurring in 1/5 of a second. A soft quadrant removal setting was empirically derived which had a slower pace and seemed more controlled with no capsule aspiration occurring in the subsequent 824 cases. The setting featured simultaneous linear control from zero to preset maximums for: aspiration flow, 20 mL/min; and vacuum, 400 mmHg, with the addition of torsional tip amplitude up to 20% after the fluidic maximums were achieved. A new setting selection procedure step toolbar was created to increase intraoperative flexibility by providing instantaneous shifting between the soft and normal settings. Conclusion A technique incorporating a reduced pace for soft quadrant acquisition and aspiration can be accomplished through the use of a dedicated setting of integrated machine parameters. Toolbar placement of the procedure button next to the normal setting procedure button provides the opportunity to instantaneously alternate between the two settings. Simultaneous surgeon control over vacuum, aspiration flow, and torsional tip motion may make removal of soft nuclear quadrants more efficient and safer.
Collapse
|