1
|
Yuan J, Wu S, Hu Z, Chen C, Ye S, Ye J. Clinical Observation of Posterior-Chamber Phakic Implantable Collamer Lens V4c Implantation in Myopic Patients with Shallow Anterior Chamber Depth: A Retrospective, Consecutive Observational Study. J Ophthalmol 2024; 2024:3181569. [PMID: 38812725 PMCID: PMC11136544 DOI: 10.1155/2024/3181569] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 03/09/2024] [Accepted: 05/06/2024] [Indexed: 05/31/2024] Open
Abstract
Purpose The reference range for the preoperative anterior chamber angle width for ICL surgery is unclear. Our objective was to assess the clinical effect and the range of anterior chamber angle width of posterior-chamber implantable collamer lens V4c (ICL V4c) implantation in patients with anterior chamber depth (ACD) < 2.8 mm. Methods Patients who underwent ICL V4c implantation with shallow ACD were included in this retrospective study. The patients' uncorrected and corrected distance visual acuity, angle of trabecular-iris (TIA), angle-opening distance (AOD500), trabecular-iris space area (TISA500), corneal endothelial cell density, vault, retinal nerve fiber layer thickness, intraocular pressure, visual field, and complications were analyzed. Results Forty-one patients (68 eyes) completed at least 12 months of follow-up (median follow-up, 30 months). The effectiveness and safety indices were 1.09 ± 0.13 and 1.04 ± 0.21, respectively. The preoperative TIA values on the nasal and temporal sides were 39.78 ± 7.68 degree (range, 25.8-65.1 degree) and 41.54 ± 8.03 degree (range, 28.5-63.00 degree). Forty-seven eyes had uncorrected distance visual acuity ≥1.0, and 55 had corrected distance visual acuity ≥1.0 at the last follow-up visit. The TIA, AOD500, and TISA500 on the nasal and temporal sides were significantly reduced compared to those before surgery (all P < 0.01); no eye had an angle closure or elevated intraocular pressure. The ICL V4c vault was 290.88 ± 153.36 μm (range, 60.0-880.0 μm). No severe complications occurred in any patient. Conclusions In patients with myopia with shallow ACD (2.55-2.79 mm), a preoperative TIA >25.8° is safe and effective for a relatively long time after surgery; however, an extended long-term close follow-up is needed.
Collapse
Affiliation(s)
- Juan Yuan
- Department of Ophthalmology, Daping Hospital, Army Medical Center of PLA, Army Medical University, Chongqing, China
- Branch of Chongqing Clinical Research Center for Eye Diseases, Chongqing, China
| | - Shuang Wu
- Department of Ophthalmology, Daping Hospital, Army Medical Center of PLA, Army Medical University, Chongqing, China
- Branch of Chongqing Clinical Research Center for Eye Diseases, Chongqing, China
| | - Zongli Hu
- Department of Ophthalmology, Daping Hospital, Army Medical Center of PLA, Army Medical University, Chongqing, China
- Branch of Chongqing Clinical Research Center for Eye Diseases, Chongqing, China
| | - Chunlin Chen
- Department of Ophthalmology, Daping Hospital, Army Medical Center of PLA, Army Medical University, Chongqing, China
- Branch of Chongqing Clinical Research Center for Eye Diseases, Chongqing, China
| | - Shiyang Ye
- Department of Ophthalmology, Southwest Hospital, Army Medical University, Chongqing, China
| | - Jian Ye
- Department of Ophthalmology, Daping Hospital, Army Medical Center of PLA, Army Medical University, Chongqing, China
- Branch of Chongqing Clinical Research Center for Eye Diseases, Chongqing, China
| |
Collapse
|
2
|
Kisiel FB, Gurumurthy GJ. Endothelial cell loss post-implantable collamer lens V4c: meta-analysis. J Cataract Refract Surg 2024; 50:420-423. [PMID: 38194352 DOI: 10.1097/j.jcrs.0000000000001389] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Accepted: 12/03/2023] [Indexed: 01/10/2024]
Abstract
Endothelial cell density (ECD) loss is a noted effect of implantable collamer lens (ICL) V4c surgery. Current literature provides a wide range of values for ECD loss postsurgery, which may not be helpful in advising patients and clinicians. A meta-analysis exploring ECD loss in ICL V4c for myopia correction was undertaken. 18 studies were included in this meta-analysis with 2 subgroup analyses to account for the variability in follow-up lengths. The average ECD loss 3 months, 12 months, and 21.25 (mean) months postsurgery were 1.32% ± 1.28% ( P < .001, 95% CI, -75.158 to -1.19), 1.75% ± 2.17% ( P < .001, 95% CI, -134.09 to 14.52), and 3.84% ± 1.78% ( P < .001, 95% CI, -156.04 to -54.26), respectively. ECD loss is most pronounced 3 months postsurgery, suggesting that acute surgical trauma was the primary contributor rather than long-term lens implantation. Overall, ICL V4c is for myopia correction exhibits similar ECD loss as seen in other ICL models, thereby affirming its safety.
Collapse
Affiliation(s)
- Filip Blazej Kisiel
- From the Department of Chemical Engineering, University of Manchester, Manchester, United Kingdom (Kisiel); Department of Medicine, University of Manchester, Manchester, United Kingdom (Gurumurthy)
| | | |
Collapse
|
3
|
Zhang GM, Zhao LJ, Xie HT, Wu MF. Anterior Segment Biometry During Accommodation After Posterior Chamber Phakic Implantable Collamer Lens Implantation. J Refract Surg 2024; 40:e164-e172. [PMID: 38466765 DOI: 10.3928/1081597x-20240212-01] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/13/2024]
Abstract
PURPOSE To evaluate the dynamic changes in anterior segment parameters during accommodation following Implantable Collamer Lens (ICL) implantation with swept-source optical coherence tomography (SS-OCT). METHODS Under the accommodation of 0.00 diopters (D), 3.00 D, and maximum amplitude, SS-OCT was used to examine the anterior segment parameters, including ICL vault, ICL depth (the distance between the corneal endothelium and the posterior surface of ICL), crystalline lens thickness, anterior chamber depth, and various parameters of the anterior chamber angle, comprising angle opening distance, angle recess area, trabecular iris space area, and trabecular iris angle. RESULTS During accommodation, the ICL vault showed a significant decrease from baseline (536 ± 278 μm) to 3.00 D (522 ± 281 μm), followed by an increase from 3.00 D to maximum amplitude (548 ± 306 μm) (analysis of variance [ANOVA], P < .001). Four eyes (2.61%) exhibited a decrease in ICL vault to less than 100 μm (47 ± 32 μm) at maximum accommodation. The ICL depth decreased significantly as accommodation increased (ANOVA, P < .001). Crystalline lens thickness increased, whereas anterior chamber depth decreased during accommodation (ANOVA, P < .001). The anterior chamber angle widened during 3.00 D of accommodation but narrowed at maximum accommodation, leading to significant changes in the angle opening distance, angle recess area, trabecular iris space area, and trabecular iris angle during accommodation (ANOVA, P < .001 for all). CONCLUSIONS The anterior segment, including ICL vault and anterior chamber angle, undergo significant dynamic changes during accommodation. These accommodative changes may require careful monitoring for the surgery design of ICL implantation. [J Refract Surg. 2024;40(3):e164-e172.].
Collapse
|
4
|
Lin F, Liu F, Niu L, Yao P, Wang X, Zhou X, Zhao J. The rate of vault changes after ICL V4c implantation and its correlation with anterior segment parameters. Heliyon 2024; 10:e25823. [PMID: 38352750 PMCID: PMC10863321 DOI: 10.1016/j.heliyon.2024.e25823] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Revised: 01/26/2024] [Accepted: 02/02/2024] [Indexed: 02/16/2024] Open
Abstract
Purpose To investigate the rate of vault changes after implantation of ICL V4c and the correlation with anterior segment parameters. Methods A total of 64 eyes were studied from the 37 myopic subjects recruited. CASIA2 was used to record the vault at 1 week, 1 month, 3 months and 6 months after the operation as well as the preoperative anterior segment parameters including pupil diameter, lens vault, anterior chamber depth, anterior chamber width, iris area (IA), iris thickness, angle opening distance, angle recess area, trabecular iris space area, and trabecular iris angle. The rates of vault change in different time intervals were compared and the correlations between the rates and anterior segment parameters were analyzed. P < 0.05 was considered statistically significant. Results The rate of vault decrease was -19.53 ± 111.28 μm/month between 1 week and 1 month, -19.90 ± 29.71 μm/month between 1 month and 3 months and -4.25 ± 18.10 μm/month between 3 months and 6 months; hence the rate was shown to slow down significantly from 3 months post-operation (P = 0.024). The average rate of vault changes showed a significant positive correlation with IA (R2 = 0.140, F = 4.980, P = 0.01). No significant correlation was found with other anterior segment parameters (all P > 0.05). Conclusion The rate of decreasing vault significantly slowed down from 3 months post-operation. A larger IA may imply a lower decreasing rate of vault change.
Collapse
Affiliation(s)
- Feng Lin
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, 200031, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, 200031, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, 200031, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, 200031, China
| | - Fang Liu
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, 200031, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, 200031, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, 200031, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, 200031, China
| | - Lingling Niu
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, 200031, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, 200031, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, 200031, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, 200031, China
| | - Peijun Yao
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, 200031, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, 200031, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, 200031, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, 200031, China
| | - Xiaoying Wang
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, 200031, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, 200031, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, 200031, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, 200031, China
| | - Xingtao Zhou
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, 200031, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, 200031, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, 200031, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, 200031, China
| | - Jing Zhao
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, 200031, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, 200031, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, 200031, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, 200031, China
| |
Collapse
|
5
|
Martínez-Plaza E, López-de la Rosa A, Ossa-Calderon C, Blázquez-Arauzo F, López-Miguel A, Maldonado MJ. Assessment of the iridocorneal angle pigmentation and structures after the implantation of EVO+ Visian Implantable Collamer Lens. Int Ophthalmol 2023; 43:4711-4718. [PMID: 37697080 DOI: 10.1007/s10792-023-02871-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Accepted: 08/26/2023] [Indexed: 09/13/2023]
Abstract
PURPOSE To evaluate the effect of EVO+ Visian Implantable Collamer Lens (ICL) implantation on the iridocorneal angle pigmentation and structures. METHODS Myopic refractive surgery candidates who underwent posterior chamber EVO+ ICL implantation were evaluated preoperatively and 3 and 6 months postoperatively. High-resolution images of the iridocorneal angle (nasal, superior, temporal and inferior quadrants) were acquired during gonioscopy. A masked observer, blinded to study visits and patients' information, evaluated the angle width, apparent iris root insertion, iris configuration, and trabecular meshwork pigmentation according to the Spaeth scale in two different occasions. The intra-rater reliability was estimated using the weighted Gwet's Agreement Coefficient (AC2). Differences between visits were analyzed using the Cochran Q test or the Friedman test. RESULTS Twenty-one patients (13 females and 8 males) aging 31.3 ± 6.3 years old were recruited. The intra-rater reliability of gonioscopy assessment was excellent for every parameter assessed (AC2 ≥ 0.97). No significant differences were found among the study visits for any quadrant in the angle width (p ≥ 0.74), apparent iris root insertion (p ≥ 0.22), iris configuration (p ≥ 0.21) and trabecular meshwork pigmentation (p ≥ 0.24). Mean pigmentation of trabecular meshwork for the four quadrants did not vary either among visits (p = 0.25). CONCLUSIONS The EVO+ ICL implantation after uneventful procedures appears not to clinically affect the iridocorneal angle pigmentation and/or structures during a short-medium follow-up using gonioscopy assessment. The intra-rater reliability of glaucoma specialists assessing iridocorneal angle structures using gonioscopy images is very high.
Collapse
Affiliation(s)
- Elena Martínez-Plaza
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Paseo de Belén 17, 47011, Valladolid, Spain
- Red Temática de Investigación Colaborativa en Oftalmología (OftaRed), Instituto de Salud Carlos III, Madrid, Spain
| | - Alberto López-de la Rosa
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Paseo de Belén 17, 47011, Valladolid, Spain
- Departamento de Física Teórica, Atómica y Óptica, Facultad de Ciencias, Universidad de Valladolid, Valladolid, Spain
| | - Carolina Ossa-Calderon
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Paseo de Belén 17, 47011, Valladolid, Spain
| | - Francisco Blázquez-Arauzo
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Paseo de Belén 17, 47011, Valladolid, Spain
| | - Alberto López-Miguel
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Paseo de Belén 17, 47011, Valladolid, Spain.
- Red Temática de Investigación Colaborativa en Oftalmología (OftaRed), Instituto de Salud Carlos III, Madrid, Spain.
- Departamento de Cirugía, Oftalmología, Otorrinolaringología y Fisioterapia, Facultad de Medicina, Universidad de Valladolid, Valladolid, Spain.
| | - Miguel J Maldonado
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Paseo de Belén 17, 47011, Valladolid, Spain
- Red Temática de Investigación Colaborativa en Oftalmología (OftaRed), Instituto de Salud Carlos III, Madrid, Spain
- Departamento de Cirugía, Oftalmología, Otorrinolaringología y Fisioterapia, Facultad de Medicina, Universidad de Valladolid, Valladolid, Spain
| |
Collapse
|
6
|
Lwowski C, Van Keer K, Ruscher T, Van Keer L, Shajari M, Kohnen T. Five-year follow-up of a posterior chamber phakic intraocular lens with a central hole for correction of myopia. Int Ophthalmol 2023; 43:4933-4943. [PMID: 37936000 PMCID: PMC10724086 DOI: 10.1007/s10792-023-02896-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Accepted: 09/27/2023] [Indexed: 11/09/2023]
Abstract
PURPOSE To evaluate intermediate and long-term visual outcomes and safety of a phakic intraocular posterior chamber lens with a central hole (ICL V4c) for myopic eyes. METHODS Retrospective, consecutive case study of patients that uneventfully received a ICL V4c for myopia correction, with a 5-year postoperative follow-up. Department of Ophthalmology, Goethe University Frankfurt, Germany. RESULTS From 241 eyes that underwent ICL implantation, we included 45 eyes with a mean age at surgery of 33 years ± 6 (18-48 years), with a 5 years follow-up. CDVA improved from 0.05logMAR ± 0.15 CDVA preoperatively to - 0.00 ± 0,07 at 5 years and did not change significantly from 3 to 5 years' time (p = 0.266). The mean spherical equivalent (SE) improved from -10.13D ± 3.39 to - 0.45D ± 0.69. The change in endothelial cell count showed a mean decrease of 1.9% per year throughout the follow-up. Safety and efficacy index were 1.16 and 0.78, respectively. Cataract formation was seen in 2 of 241 eyes (0.8%), but in none of the 45 eyes that finished the 5-year follow-up. CONCLUSIONS Our data show a good intermediate and long-term stability, efficiency, and safety of ICL V4c phakic lenses in myopic eyes comparable to other known literature.
Collapse
Affiliation(s)
- Christoph Lwowski
- Department of Ophthalmology, Goethe-University, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany
| | - Karel Van Keer
- Department of Ophthalmology, Goethe-University, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany
- Department of Ophthalmology, UZ Leuven, Leuven, Belgium
| | - Tim Ruscher
- Department of Ophthalmology, Goethe-University, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany
| | - Luisa Van Keer
- Department of Ophthalmology, Goethe-University, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany
| | - Mehdi Shajari
- Department of Ophthalmology, Goethe-University, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany
- Department of Ophthalmology, Ludwig Maximilian-University, Munich, Germany
| | - Thomas Kohnen
- Department of Ophthalmology, Goethe-University, Theodor-Stern-Kai 7, 60590, Frankfurt Am Main, Germany.
| |
Collapse
|
7
|
Sánchez-Trancón A, Manito SC, Sierra OT, Baptista AM, Serra PM. Prediction model of the horizontal trabecular iris angle after phakic posterior chamber implantable intraocular lens surgery. J Cataract Refract Surg 2023; 49:732-739. [PMID: 36807205 DOI: 10.1097/j.jcrs.0000000000001171] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Accepted: 02/14/2023] [Indexed: 02/23/2023]
Abstract
PURPOSE To determine the predictors of the postoperative horizontal trabecular iris angle (TIA 750 ) after phakic posterior chamber implantable intraocular lens (IOL) surgery. SETTING Ophthalmology Clinic Vista Sánchez Trancón, Badajoz, Spain. DESIGN Retrospective case series. METHODS 330 eyes implanted with spherical/toric implantable collamer lens (ICL) were included in this study. From 230 eyes implanted with 13.2 mm ICL, these were divided in modeling (n = 180) and evaluation group (n = 50). Two groups implanted with 12.6 mm and 13.7 mm (n = 50 each) were also used as evaluation. Anterior-segment optical coherence tomography was used preoperatively to perform anterior chamber biometry (angle-to-angle [ATA] distance, crystalline lens rise, anterior chamber depth [ACD], cornea sagittal depth, pupil diameter, nasal/temporal TIA 750 ); postoperatively for measuring the vault, pupil diameter and nasal/temporal TIA 750 . Corneal curvature and horizontal visible iris diameter were measured using optical tomography. Bivariate correlation analysis was used to determine associations between preoperative and postoperative horizontal TIA 750 with anterior chamber biometry, ICL-related parameters and age. Finally, a multivariate linear regression model was constructed for predicting the postoperative TIA 750 . RESULTS Horizontal TIA 750 reduced from 42.9 ± 8.0 degrees preoperatively to 24.4 ± 5.6 degrees postoperatively. Postoperative TIA 750 was positively correlated with the preoperative TIA 750 , cornea sagittal depth and ACD, and negatively associated with the vault. The main predictors of the postoperative TIA 750 were the preoperative parameters, TIA 750 , ICLsize - ATA and pupil diameter (adjusted- R2 = 0.39). The limits of agreement between predicted and real TIA 750 were close to ±10 degrees. CONCLUSIONS Implantation of a phakic posterior chamber implantable IOL leads to a reduction in TIA 750 and the main factors contributing for this are the preoperative TIA 750 aperture and the vault.
Collapse
Affiliation(s)
- Angel Sánchez-Trancón
- From the Ophthalmology Clinic Vista Sánchez Trancón, Badajoz, Spain (Sánchez-Trancón, Manito, Sierra, Serra); Centre of Physics, University of Minho, Braga, Portugal (Baptista)
| | | | | | | | | |
Collapse
|
8
|
Tang C, Sun T, Sun Z, Duan H, Liu Y, Zhao L, Li W, Bian L, Qi H. Evaluation of biometric indicators of anterior segment parameters after ICL implantation by swept-source optical coherence tomography. BMC Ophthalmol 2023; 23:193. [PMID: 37131213 PMCID: PMC10155418 DOI: 10.1186/s12886-023-02942-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2023] [Accepted: 04/25/2023] [Indexed: 05/04/2023] Open
Abstract
BACKGROUND To evaluate anterior segment structural alterations after implantable collamer lens (ICL) implantation in myopic patients using swept-source quantitative optical coherence tomography (SS-OCT). METHODS This prospective study included 47 eyes in 24 patients with preoperative spherical equivalent ≥ -3.00 D. Patients underwent ICL implantation at Department of Ophthalmology, Peking University Third Hospital, from May 2021 to December 2022. SS-OCT was used to measure anterior chamber width (ACW), angle opening distance (AOD), angle recess area (ARA), trabecular-iris area (TISA), trabecular-iris angle (TIA), iridotrabecular contact (ITC) area, and ITC Index before ICL implantation surgery and at 1 month follow-up. The correlations among the ITC index, vault, and angle parameters were analysed. Receiver operating characteristic (ROC) analysis was used to explore the ability of the vault to identify eyes with suspected angle-closure. RESULTS At one month following ICL implantation, the ITC area was 0.396 ± 0.37 mm2, and the ITC index is 8.143 ± 5.439%. All angle parameters, except ACW, showed a statistically significant reduction on SS-OCT (P < 0.05). Mean AOD500, AOD750, ARA500, ARA750, TISA500, TISA750, TIA500, and TIA750 values at one month postoperatively decreased by 60.0%, 60.4%, 58.1%, 59.2%, 57.3%, 58.7%, 48.8%, and 50.7%, respectively. The vault was positively correlated with the ITC index and percent change in anterior chamber angle parameters. A vault of > 0.659 mm was found to be optimal for angle-closure suspect with a sensitivity of 85.2% and a specificity of 53.9%. CONCLUSIONS Anterior chamber angle parameters decreased one month after ICL implantation, and their percentage changes and ITC index correlated with the vault. When the vault is larger than 0.659 mm, it is necessary to be alert to possible closed angle suspicion.
Collapse
Affiliation(s)
- Chuhao Tang
- Department of Ophthalmology, Peking University Third Hospital, Beijing Key 9 Laboratory of Restoration of Damaged Ocular Nerve, Beijing, China
| | - Tong Sun
- Department of Ophthalmology, Peking University Third Hospital, Beijing Key 9 Laboratory of Restoration of Damaged Ocular Nerve, Beijing, China
| | - Zhengze Sun
- Department of Ophthalmology, Peking University Third Hospital, Beijing Key 9 Laboratory of Restoration of Damaged Ocular Nerve, Beijing, China
| | - Hongyu Duan
- Department of Ophthalmology, Peking University Third Hospital, Beijing Key 9 Laboratory of Restoration of Damaged Ocular Nerve, Beijing, China
| | - Yilin Liu
- Department of Ophthalmology, Peking University Third Hospital, Beijing Key 9 Laboratory of Restoration of Damaged Ocular Nerve, Beijing, China
| | - Lu Zhao
- Department of Ophthalmology, Peking University Third Hospital, Beijing Key 9 Laboratory of Restoration of Damaged Ocular Nerve, Beijing, China
| | - Wenlong Li
- Department of Ophthalmology, Peking University Third Hospital, Beijing Key 9 Laboratory of Restoration of Damaged Ocular Nerve, Beijing, China
| | - Linbo Bian
- Department of Ophthalmology, Peking University Third Hospital, Beijing Key 9 Laboratory of Restoration of Damaged Ocular Nerve, Beijing, China
| | - Hong Qi
- Department of Ophthalmology, Peking University Third Hospital, Beijing Key 9 Laboratory of Restoration of Damaged Ocular Nerve, Beijing, China.
| |
Collapse
|
9
|
Lisa Fernández C, Alió Del Barrio J, Alvarez-Rementería Capelo L, Cano Ortiz A, Castaño Manotas A, Fernández-Vega Cueto L, Hernández-Barahona Campos M, Lamarca Mateu J, López-Marín Espigares I, Monteiro T, Pastor Pascual F, Pérez Izquierdo R. State of refractive surgery with Visian ICL posterior chamber phakic lens in Spain. ARCHIVOS DE LA SOCIEDAD ESPANOLA DE OFTALMOLOGIA 2023; 98:98-104. [PMID: 36115821 DOI: 10.1016/j.oftale.2022.06.018] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Accepted: 06/10/2022] [Indexed: 02/07/2023]
Abstract
OBJECTIVES To analyse the state of refractive surgery with Visian ICL phakic lens implantation in Spain, indicating the mean ranges of implanted powers, visual and refractive outcomes obtained and safety and efficacy indices. METHOD This is a population-based, cross-sectional, descriptive, analytical, retrospective, multicentre study in which each co-author collected data from at least the last 10 patients (up to a maximum of 30) with Visian ICL phakic lens implantation. One eye from each subject was randomly selected for study inclusion, and the variables analysed were: age, gender, visual acuities with and without correction pre and post-surgery, preoperative and residualrefraction, keratometry, endothelial cellular density, anterior chamber depth from endothelium, central corneal pachymetry, intraocular pressure, white-white, implanted lens (power and size), expected and achieved spherical equivalent (SEQ) post-surgery at one month after surgery. RESULTS A sample of 140 eyes was obtained from 140 patients with a mean age of 31.35 ± 7.28 years. Mean preoperative SEQ was -6.33 ± 3.69D, mean CDVA was 0.96 ± 0.16, ACD was 3.30 ± 0.29 mm, WTW 12.02 ± 0.40 mm, CCT 535.03 ± 37.68 µm, ECD 2684.37 ± 313.74 cels/mm2 and IOP 14.84 ± 2.59 mmHg. 66.4% of the implanted lenses were spherical ICLs and 33.6% toric, with a mean power of -7.81 ± 4.09D and a mean cylinder of 2.27 ± 1.23D. 5.7% of the implanted lenses were hypermetropic. The mean SEQ target selected was +0.04 ± 0.27D. 48.92% of the implanted lenses were of size 13.2 mm, with the remaining 36.69, 10.79 and 3.60% being of sizes 12.6, 12.1 and 13.7 mm, respectively. At one month after surgery a residual SEQ of -0.01 ± 0.31D was obtained. The efficacy and safety indices were 1.06 ± 0.18 and 1.10 ± 0.19, respectively. The mean central vault was 508.80 ± 201.04 µm. The accuracy between the calculated SEQ and the obtained SEQ was 99.3% for spherical lenses and 88.2% for Cyl correction. The mean ECD at 1 month after surgery was 2805.53±273.30céls/mm2, which was a difference from preoperative of 0.11% (p = 0.922), similarly, the mean IOP was 13.98 ± 2.57 mmHg, which was a difference of -0.92 ± 2.80 mmHg. CONCLUSIONS ICL phakic lens surgery is an effective, safe and predictable procedure. There were no significant changes in endothelial cell count or intraocular pressure measurement one month after surgery.
Collapse
Affiliation(s)
- C Lisa Fernández
- Instituto Oftalmológico Fernández-Vega, Oviedo, Asturias, Spain.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Martínez-Plaza E, López-de la Rosa A, López-Miguel A, Holgueras A, Maldonado MJ. EVO/EVO+ Visian Implantable Collamer Lenses for the correction of myopia and myopia with astigmatism. Expert Rev Med Devices 2023; 20:75-83. [PMID: 36708714 DOI: 10.1080/17434440.2023.2174429] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
INTRODUCTION Intraocular lens implantation in phakic eyes for the correction of refractive error is currently a widespread procedure. The EVO and EVO+ Visian Implantable Collamer Lenses (ICL) are two of the most prevalent lenses implanted. They incorporate a central orifice to avoid the need for iridotomy. The main difference between both ICL is the higher optical diameter zone provided by the EVO+, allowing a better quality of vision at night. This review aims to provide an overview of the current ICL models available for correcting myopia and myopic astigmatism. AREAS COVERED During the last decade, more than 100 scientific papers analyzing the performance of EVO and EVO+ lenses have been published. This review describes the objective visual performance achieved with the implantation of central hole ICL lenses and the subjective perception of the patients implanted with these lenses. In addition, the safety and the potential complications associated with undergoing an EVO and EVO+ ICL implantation have been addressed. EXPERT OPINION Refractive surgeons and candidates to undergo ICL implantation should be aware of the excellent safety and visual outcomes provided by the implantation of central hole ICL lenses. However, future research could address minor issues currently not resolved.
Collapse
Affiliation(s)
- Elena Martínez-Plaza
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Valladolid, Spain
| | | | - Alberto López-Miguel
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Valladolid, Spain
| | - Alfredo Holgueras
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Valladolid, Spain
| | - Miguel J Maldonado
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Valladolid, Spain
| |
Collapse
|
11
|
ICL Postimplantation Decentration and Tilt in Myopic Patients with Primary Iridociliary Cysts. J Ophthalmol 2023; 2023:3475468. [PMID: 36700115 PMCID: PMC9870672 DOI: 10.1155/2023/3475468] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 10/09/2022] [Accepted: 10/25/2022] [Indexed: 01/18/2023] Open
Abstract
Purpose To observe the decentration and tilt of implantable collamer lens (ICL) as well as possible visual effects postimplantation in primary iridociliary cysts. Methods The present investigation was a retrospective cohort study. All 48 patients (91 eyes) who underwent ICL surgery at the Center of Refraction Surgery of Tianjin Medical University Eye Hospital between July 2018 and May 2020 were split into two groups based on the absence or presence of primary iridociliary cysts established by ultrasonic biological microscopy (UBM) examination. Intraocular pressure (IOP), corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), anterior chamber angle (ACA), anterior chamber volume (ACV), and anterior chamber depth (ACD) were recorded preoperatively and postoperatively at 1, 6, and 12 months. Additionally, we performed an analysis of the ICL vault, decentration, and tilt using a rotating Scheimpflug Oculus Pentacam camera system at 1, 6, and 12 months after surgery. Results No serious complications were observed. Significant postoperative improvement (P < 0.05) of UDVA was established in the two studied groups; however, we did not observe statistically significant intergroup differences (P > 0.05) throughout the entire research period. In each group, the preoperative ACA, ACV, and ACD were statistically significantly reduced (P < 0.05), but no such decrease was established between their postoperative values (P > 0.05). We observed no statistical differences between both groups with regard to their values of IOP, ACA, ACV, ACD, ICL vault, ICL decentration, and tilt at 1, 6, and 12 months after surgery. Similarly, no statistically significant within-group correlation (P > 0.05) of the decentration of ICL and the tilt and the CDVA values was established. Conclusion No postimplantation effect of ICL with a central hole on vision was established in myopia patients with primary iridociliary cysts, within certain limits of ICL decentration and tilt values.
Collapse
|
12
|
Liu F, Xia F, Niu L, Zhao J, Wang X, Zhou X. Early Assessment of Circumferential Anterior Segment Structures Following Implantable Collamer Lens V4c Implantation Via SS-OCT. Transl Vis Sci Technol 2022; 11:4. [PMID: 36331273 PMCID: PMC9645365 DOI: 10.1167/tvst.11.11.4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Purpose To explore early changes in circumferential anterior segment structures following Implantable Collamer Lens (ICL) V4c implantation via swept-source optical coherence tomography (SS-OCT). Methods In 103 eyes of 56 myopic patients undergoing ICL V4c surgery, anterior segments were measured via SS-OCT to compute local anterior chamber angle (ACA) parameters on the nasal–temporal (0°–180°), superior–inferior (90°–270°), and superior nasal–inferior temporal (80°–260°) meridians, including angle-opening distance at 500 µm (AOD500), trabecular–iris space area at 500 µm (TISA500), trabecular–iris angle at 500 µm (TIA500), and circumferential ACA parameters, including AOD area at 500 µm (AODA500), trabecular–iris circumference volume at 500 µm (TICV500), and the index and area of iris–trabecular contact (ITC). ACA parameters were compared preoperatively and at 1 week, 1 month, and 3 months postoperatively and compared among quadrants. Mixed-effects model was used to evaluate the parameters correlated with the post-ITC parameters. Results The mean AOD500, TISA500, TIA500, AODA500, and TICV500 were decreased by 65.4% to 71%, 64.1% to 69.3%, 53.8% to 61.5%, 69.9%, and 69.2%, respectively, at 1 week postoperatively. The ITC index and area values rose from 1.436% ± 4.427% and 0.070 ± 0.254 mm2 to 12.343% ± 13.216% and 0.903 ± 1.304 mm2 (all P < 0.05). No further decreases in ACA parameters were observed beyond 1 week postoperatively (all P > 0.05). Significant differences were observed among quadrants, with the narrowest in the superior–nasal quadrant, followed by the superior quadrant. The 3-month vault was significantly correlated with the ITC index and area at 3 months postoperatively. Conclusions Anterior segment structures were significantly shallow at 1 week with no further decreases thereafter. In light of anatomical variability, we recommend circumferential meridian scan to assess angle status, with special attention to the superior–nasal and superior quadrants. Translational Relevance We investigated the early changes in circumferential anterior segment structures following ICL V4c implantation, thus providing a better perspective for understanding anterior segment structural characteristics after ICL V4c surgery.
Collapse
Affiliation(s)
- Fang Liu
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Fei Xia
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Lingling Niu
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Jing Zhao
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xiaoying Wang
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xingtao Zhou
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| |
Collapse
|
13
|
Zhang H, Gong R, Zhang X, Deng Y. Analysis of perioperative problems related to intraocular Implantable Collamer Lens (ICL) implantation. Int Ophthalmol 2022; 42:3625-3641. [PMID: 35731355 PMCID: PMC9587946 DOI: 10.1007/s10792-022-02355-w] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2021] [Accepted: 04/18/2022] [Indexed: 02/05/2023]
Abstract
PURPOSE To introduce a modified procedure of ICL implantation, to summarize the perioperative problems and their corresponding treatment after myopia correction with Implantable Collamer Lens (ICL), and to compare the difference of complications between the no-hole ICL and hole ICL. METHODS We searched all articles on ICL-related perioperative problems and their corresponding treatment in Scopus, Embase, PubMed and Web of Science databases for the last 22 years. RESULTS ICL implantation is safe, effective, stable and predictable in the correction of myopia, hyperopia and astigmatism, but can also cause a series of perioperative problems, including intraoperative and postoperative complications. CONCLUSION There are many kinds of complications related to ICL, but the common intraoperative and postoperative complications mainly include abnormality of arch height, abnormal position of ICL, loss of corneal endothelial cells and corneal decompensation, high intraocular pressure and secondary glaucoma, cataract and night vision symptoms. Compared with ICL without central pore, the incidence of complications such as loss of corneal endothelial cells and corneal decompensation, high intraocular pressure and secondary glaucoma and cataract was relatively lower in central hole ICL, while postoperative complications such as night vision symptoms were obvious.
Collapse
Affiliation(s)
- Hao Zhang
- Department of Ophthalmology, West China Hospital, Sichuan University, No.37, Guoxue Xiang, Chengdu, 610041 Sichuan China
| | - Rui Gong
- Department of Ophthalmology, West China Hospital, Sichuan University, No.37, Guoxue Xiang, Chengdu, 610041 Sichuan China
| | - Xiaolan Zhang
- Department of Ophthalmology, West China Hospital, Sichuan University, No.37, Guoxue Xiang, Chengdu, 610041 Sichuan China
| | - Yingping Deng
- Department of Ophthalmology, West China Hospital, Sichuan University, No.37, Guoxue Xiang, Chengdu, 610041 Sichuan China
| |
Collapse
|
14
|
Evaluation of Visual Outcome of 2 Phakic Posterior Chamber Implantable Lenses in High Myopia: A Comparative Study. Eye Contact Lens 2021; 48:38-44. [PMID: 34775453 DOI: 10.1097/icl.0000000000000854] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/09/2021] [Indexed: 10/19/2022]
Abstract
PURPOSE To evaluate and compare the visual outcomes of two phakic intraocular lenses in high myopia. METHODS A prospective comparative study was undertaken on 50 eyes of 26 patients {age ≥21 years and divided into two groups (implantable collamer lens [ICL] V4c, n=25 eyes and refractive implantable lens [RIL], n=25 eyes)}. Patients were evaluated for uncorrected distance visual acuity (UCVA), best-corrected distance visual acuity, manifest refractive spherical equivalent (MRSE), contrast sensitivity, intraocular pressure, dilated fundus examination, trabecular-iris angle (TIA), anterior chamber depth, horizontal white-to-white diameter, wavefront aberrometry, and endothelial cell (EC) count. All patients were followed up until 6 months and additionally evaluated for anterior chamber inflammation, cataract, and lens vault. RESULTS The baseline parameters (UCVA, MRSE, and EC count) and postoperative improvement in UCVA, contrast sensitivity, MRSE, EC loss, safety index, and efficacy index were comparable between both the lenses. The improvement in aberrometric profile was significantly better in the ICL group. The mean postoperative vault was higher in RIL group (434.88±162.48 μm vs. 547.24±159.83 μm, P=0.0173); however, the vault was within normal range in both the groups. The decrease in mean TIA was significantly higher in RIL group (8.58 vs. 13.45 μm, P=0.0073). CONCLUSION Acrylic phakic lens can be considered as a suitable alternative to collamer lens for refractive correction of high myopia. The collamer lenses showed slight superiority in some qualitative visual parameters; however, collamer lenses do not present with subjective complaints in the patients.
Collapse
|
15
|
Almorín-Fernández-Vigo I, Sánchez-Guillén I, Fernández-Vigo JI, De-Pablo-Gómez-de-Liaño L, Kudsieh B, Fernández-Vigo JÁ, Macarro-Merino A. Agreement between optical coherence and Scheimpflug tomography: Vault measurements and reproducibility after implantable collamer lens implantation. J Fr Ophtalmol 2021; 44:1370-1380. [PMID: 34330550 DOI: 10.1016/j.jfo.2021.03.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 02/16/2021] [Accepted: 03/15/2021] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate the agreement between Scheimpflug tomography (Pentacam, Oculus) and anterior segment optical coherence tomography (AS-OCT, RTVue 100, Optovue) as well as the reproducibility of each technique in assessing the lens-ICL distance (vault) after implantable collamer lens (ICL) implantation. METHODS The vault was measured manually with Scheimpflug tomography and AS-OCT. Intraclass correlation coefficients (ICC) and Bland-Altman plots were used to determine the reproducibility of measurements and the agreement between them. Multivariate regression analysis was performed to identify predictors of differences in vault measurements between devices. RESULTS 80 eyes of 46 ICL patients were analyzed. Mean patient age was 33.8±7.4 years (range, 21 to 51), and 27 (59%) were women. The preoperative spherical equivalent refraction ranged from -26 to 8.5 diopters (D). The mean vault measured by AS-OCT was 558.8±240.2μm (range, 162 - 1220) vs. 430.1±215.3μm (range, 0 to 1070) by Pentacam. AS-OCT yielded vault values, on average, 128.1±64.6μm higher than the Pentacam (range, -22 to 293μm). The ICC values for consistency and absolute agreement were 0.960 and 0.928, respectively. Reproducibility of vault measurements was excellent for both devices (ICC≥0.946). Four parameters-vault, pupil diameter (PD), PD differences between devices, and preoperative spherical equivalent refraction-were significant predictors of differences in vault measurements (adjusted-R2=0.412; P<0.001). CONCLUSIONS Agreement between AS-OCT and Pentacam for vault measurement was good. Vaults were higher when measured by AS-OCT. These differences are clinically relevant, and therefore these devices cannot be used interchangeably to measure vault.
Collapse
Affiliation(s)
| | - I Sánchez-Guillén
- Centro Internacional de Oftalmología Avanzada, Badajoz, Spain; Department of ophthalmology, hospital Llerena-Zafra, Badajoz, Spain
| | - J I Fernández-Vigo
- Centro Internacional de Oftalmología Avanzada, Madrid, Spain; Department of ophthalmology, hospital Clínico San Carlos, Madrid, Spain
| | | | - B Kudsieh
- Centro Internacional de Oftalmología Avanzada, Madrid, Spain; Department of ophthalmology, hospital Puerta de Hierro, Madrid, Spain
| | - J Á Fernández-Vigo
- Centro Internacional de Oftalmología Avanzada, Badajoz, Spain; Centro Internacional de Oftalmología Avanzada, Madrid, Spain; School of Medicine, Universidad de Extremadura, Badajoz, Spain
| | | |
Collapse
|
16
|
Montés‐Micó R, Ruiz‐Mesa R, Rodríguez‐Prats JL, Tañá‐Rivero P. Posterior-chamber phakic implantable collamer lenses with a central port: a review. Acta Ophthalmol 2021; 99:e288-e301. [PMID: 32841517 PMCID: PMC8246543 DOI: 10.1111/aos.14599] [Citation(s) in RCA: 56] [Impact Index Per Article: 18.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Accepted: 07/26/2020] [Indexed: 02/06/2023]
Abstract
We aimed to summarize the outcomes reported following the implantation of the V4c implantable collamer lens with a central port (ICL, STAAR Surgical Inc) for myopia correction. A literature search in PubMed, Web of Science and Scopus was carried out to identify publications reporting clinical outcomes of patients who were implanted with the V4c ICL model and had a follow‐up period of at least 6 months. A total of 35 clinical studies published between 2012 and 2020 were included in the present review. A comprehensive analysis of the available data was performed, focusing on visual and refractive outcomes at different time‐points post‐surgery. In addition, adverse events and other parameters such as endothelial cell density, intraocular pressure and vault measurements—which were evaluated in some of the studies—were also compared. This review encompassed a total of 2904 eyes. The outcomes reported in this review lead us to conclude that ICL V4c implantation for myopia correction is a safe and efficient procedure, with stable visual and refractive outcomes and low adverse event rates. The patient’s anterior segment should be thoroughly characterized, and the ICL parameters should be carefully selected so as to achieve good outcomes and avoid complications.
Collapse
Affiliation(s)
- Robert Montés‐Micó
- Oftalvist Alicante Spain
- Optics and Optometry and Vision Sciences Department University of Valencia Valencia Spain
| | | | | | | |
Collapse
|
17
|
Zhao J, Zhao J, Yang W, Miao H, Niu L, Shang J, Wang X, Zhou X. Peripheral Anterior Chamber Depth and Angle Measurements Using Pentacam After Implantation of Toric and Non-toric Implantable Collamer Lenses. Front Med (Lausanne) 2021; 8:610590. [PMID: 33585524 PMCID: PMC7873523 DOI: 10.3389/fmed.2021.610590] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2020] [Accepted: 01/05/2021] [Indexed: 11/23/2022] Open
Abstract
Purpose: To evaluate the characteristics of peripheral anterior chamber measurements by Pentacam after posterior implantable collamer lenses (ICL) and toric ICL (TICL) with central hole (V4c) implantation. Methods: Prospective, non-randomized consecutive case series. Forty-six patients undergoing ICL implantation in one eye (Group A) and identically sized TICL in the contralateral eye (Group B) in the Refractive Surgery Center of Eye and ENT Hospital of Fudan University were prospectively included. According to ICL/TICL size, these eyes were further divided into four subgroups. Peripheral anterior chamber depth (PACD) and angle (ACA) in nasal and temporal sides were measured using Pentacam pre-operatively and 12-month post-operatively. Results: The safety indices were 1.34 ± 0.32 and 1.25 ± 0.16 and the efficacy indices were 1.20 ± 0.24 and 1.19 ± 0.19 for ICL and TICL groups, respectively. There was no significant difference in pre-operative PACD or ACA between the two groups. Post-operative PACD and ACA were significantly lower than pre-operative values. Variations of PACD and ACA of TICL group were significantly larger than those of ICL group. The change of ACA for 13.2 mm lenses was significantly larger than that of 12.6 mm lenses. Pre-operative CACD and vault were significantly associated with post-operative PACD, while pre-operative ACA and vault were significantly associated with post-operative ACA. Conclusions: Variations of PACD and ACA were greater in eyes after TICL (V4c) implantation compared with identically sized ICL (V4c) implantation and with larger size than smaller size lens implantation. Pre-operative anterior chamber structure and vault affect post-operative PACD and ACA.
Collapse
Affiliation(s)
- Jiao Zhao
- Department of Ophthalmology, People's Hospital of Leshan, Leshan, China
| | - Jing Zhao
- Eye Institute and Department of Ophthalmology, Eye, Ear, Nose and Throat Hospital, Fudan University, Shanghai, China.,National Health Center Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Wen Yang
- Department of Ophthalmology, The Third People's Hospital of Chengdu, The Affiliated Hospital of Southwest Jiaotong University, Chengdu, China
| | - Huamao Miao
- Eye Institute and Department of Ophthalmology, Eye, Ear, Nose and Throat Hospital, Fudan University, Shanghai, China.,National Health Center Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Lingling Niu
- Eye Institute and Department of Ophthalmology, Eye, Ear, Nose and Throat Hospital, Fudan University, Shanghai, China.,National Health Center Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Jianmin Shang
- Eye Institute and Department of Ophthalmology, Eye, Ear, Nose and Throat Hospital, Fudan University, Shanghai, China.,National Health Center Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xiaoying Wang
- Eye Institute and Department of Ophthalmology, Eye, Ear, Nose and Throat Hospital, Fudan University, Shanghai, China.,National Health Center Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xingtao Zhou
- Eye Institute and Department of Ophthalmology, Eye, Ear, Nose and Throat Hospital, Fudan University, Shanghai, China.,National Health Center Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| |
Collapse
|
18
|
Takagi Y, Kojima T, Nishida T, Nakamura T, Ichikawa K. Prediction of anterior chamber volume after implantation of posterior chamber phakic intraocular lens. PLoS One 2020; 15:e0242434. [PMID: 33196664 PMCID: PMC7668562 DOI: 10.1371/journal.pone.0242434] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2020] [Accepted: 11/03/2020] [Indexed: 11/18/2022] Open
Abstract
PURPOSE To predict the anterior chamber volume (ACV) after implantable collamer lens (ICL) implantation based on ICL size and parameters of anterior segment optical coherence tomography (AS-OCT). DESIGN Retrospective study. METHODS This study included 222 eyes of 222 patients who underwent ICL implantation at Nagoya Eye Clinic. The patients were divided into two groups: prediction group, for creating the prediction equation (148 eyes, mean age: 32.11 ± 8.04 years), and verification group, for verifying the equation (74 eyes, mean age: 33.03 ± 6.74 years). The angle opening distance (AOD), anterior chamber width (ACW), ACV, anterior chamber depth, lens vault, angle-to-angle distance, angle recess area, and trabecular iris space area were calculated using AS-OCT. A stepwise multiple regression analysis was performed. After the creation of the prediction equation, its accuracy was verified in the verification group. RESULTS The ACV, AOD750, ACW, and ICL size were selected as explanatory variables to predict postoperative ACV. Mean predicted (114.2 ± 21.83 mm3) and actual postoperative ACVs (116.1 ± 25.41 mm3) were not significantly different (P = 0.269); absolute error was 10.59 ± 9.13 mm3. In addition, there was high correlation between actual and predictive ACV (adjusted R2 = 0.6996, p < 0.0001). Bland-Altman plot revealed that there was no addition or proportional error between predicted and actual postoperative ACV. CONCLUSION Postoperative ACV was accurately predicted using AS-OCT parameters and ICL size. This prediction equation may be useful for making decisions regarding ICL size.
Collapse
Affiliation(s)
- Yuki Takagi
- Department of Ophthalmology, Iida Municipal Hospital, Nagano, Japan
| | - Takashi Kojima
- Nagoya Eye Clinic, Nagoya, Japan
- Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan
- * E-mail:
| | | | | | | |
Collapse
|
19
|
Kato S, Shimizu K, Igarashi A. Assessment of low-vault cases with an implantable collamer lens. PLoS One 2020; 15:e0241814. [PMID: 33147267 PMCID: PMC7641440 DOI: 10.1371/journal.pone.0241814] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2020] [Accepted: 10/20/2020] [Indexed: 11/27/2022] Open
Abstract
This study aimed to examine clinical results in low-vault eyes after implementation of a Hole implantable collamer lens (KS-AquaPORT™, STAAR Surgical Company) in terms of visual outcomes and complications over a one-year follow-up period. This was a retrospective cohort study of subjects who underwent Hole implantable collamer lens surgery at Sanno Hospital, exhibited low vault, and were followed up for 1 year. Patients were included if they met the following criteria: 20≤ age ≤55 years; stable refraction ≥6 months; -1.0 to -20.0 diopters of myopia; endothelial cell density ≥1800 cells/mm2; and no history of ocular surgery, progressive corneal degeneration, cataract, glaucoma, or uveitis. Main outcome measurements were the safety and efficacy indices, predictability, and vault. Values were indicated as the mean ± standard deviation. Subjects included 16 patients (age: 38 ± 8 years; 6 males; 25 eyes). Toric lenses were utilized for 10 eyes. Implantable collamer lens size was 12.1, 12.6, and 13.2 mm for 18, 6, and 1 eye(s), respectively. One year postoperatively, the safety index was 1.07; for 22 eyes with a target refraction of that of emmetropic eyes, the efficacy index was 0.90; and 96% of eyes were within ± 0.50 diopters of attempted versus achieved spherical equivalent correction. Postoperative vault was 142 ± 60 μm. One year postoperatively, no additional surgery was required for rotation of toric implantable collamer lens, and no advanced cataracts, increased intraocular pressure, or decreased endothelial cells were observed. In conclusion, Hole implantable collamer lens yielded satisfactory visual outcomes and no postoperative complications for low-vault eyes, suggesting its suitability for such cases.
Collapse
Affiliation(s)
- Sayaka Kato
- Eye Center, Sanno Hospital, Tokyo, Japan
- * E-mail:
| | | | | |
Collapse
|
20
|
Effect of Angle Opening Parameters on Corneal Endothelial Cell Density and Intraocular Pressure after Posterior Chamber Phakic Intraocular Lens Implantation. J Clin Med 2020; 9:jcm9092704. [PMID: 32825643 PMCID: PMC7565728 DOI: 10.3390/jcm9092704] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2020] [Revised: 08/14/2020] [Accepted: 08/18/2020] [Indexed: 11/30/2022] Open
Abstract
This study aimed to investigate the time courses of angle opening parameters and the relationships of these with the corneal endothelial cell density (ECD) and the intraocular pressure (IOP) after posterior chamber phakic intraocular lens (Visian ICLTM, STAAR Surgical) implantation. We evaluated 116 eyes of 59 consecutive patients (mean age ± standard deviation, 34.0 ± 8.8 years) who underwent V5 implantable collamer lens (ICL) implantation. Preoperatively and 1 day, 1 week, and 1, 3, and 18 months postoperatively, we quantitatively measured the angle opening distance at 500 µm (AOD500), the trabecular-iris space area (TISA500), and the trabecular iris angle (TIA500), using anterior segment optical coherence tomography (CASIA 2, Tomey), and assessed the relationships of these measurements with ECD and IOP in ICL-implanted eyes. All angle parameters (AOD500, TISA500, and TIA500) significantly decreased 1 day postoperatively but remained stable thereafter. At 18 months postoperatively, we found no significant correlations of the angle parameters with ECD (Pearson correlation coefficient r = −0.108, p = 0.249 for AOD500; r = −0.162, p = 0.083 for TISA500; r = −0.022, p = 0.815 for TIA500) or between the angle parameters and IOP (r = −0.106, p = 0.256 for AOD500; r = −0.021, p = 0.826 for TISA500; r = −0.018, p = 0.850 for TIA500). The angle opening metrics significantly decreased immediately after ICL implantation but remained stable thereafter. Narrowing of the angle did not significantly affect ECD or IOP in ICL-implanted eyes during the 18-month postoperative period.
Collapse
|
21
|
The Relationship between Anterior Chamber Angle and Intraocular Pressure Early after V4c Implantable Collamer Lens Implantation. J Ophthalmol 2020; 2020:4014512. [PMID: 32774903 PMCID: PMC7391088 DOI: 10.1155/2020/4014512] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2020] [Revised: 06/11/2020] [Accepted: 06/24/2020] [Indexed: 11/17/2022] Open
Abstract
Purpose To confirm the relationship between anterior chamber angle (ACA) and intraocular pressure (IOP) early after V4c implantable collamer lens (ICL) implantation. Methods Patients were assigned to two groups: (1) right eyes (control group) and (2) left eyes (experimental group), with miosis conducted immediately after ICL implantation in the left eyes. IOP, angle opening distance (AOD), trabecular-iris angle (TIA), and pupil diameter (PD) were compared between two groups at postoperative hours 1, 2, and 24. The relationship between ACA, PD, and IOP was analyzed by multiple linear regression. Result Thirty-six eyes of 18 patients were enrolled. The prevalence of ocular hypertension (OHT, defined as IOP ≥ 21 mmHg) was 61.11% and 16.67% in the right and left eyes, respectively, (χ2 = 7.481, p=0.006). At postoperative hours 1 and 2, IOP and PD were significantly higher (p < 0.001) in the right eyes, and TIA and AOD were significantly lower (p < 0.05) in the right eyes than in the left eyes. There was no significant difference at 24 h postoperative in these parameters. After the right eye ICL implantation, the changes of AOD 500 and PD were both linearly correlated with postoperative IOP change (β = −23.707 and 1.731, respectively; p = 0.013 and 0.002, respectively). Conclusion The ACA was significantly narrowed immediately after V4c ICL implantation. There was a negative linear correlation between ACA and early IOP and a positive linear correlation between PD and early IOP. We recommend the use of intracameral miotics immediately after V4c ICL implantation to reduce the incidence of IOP spikes.
Collapse
|
22
|
Anterior chamber angle width, central vault and intraocular pressure changes after 12 months of Visian collamer lens implantation. Int Ophthalmol 2020; 40:2047-2053. [DOI: 10.1007/s10792-020-01381-w] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2020] [Accepted: 04/10/2020] [Indexed: 12/30/2022]
|
23
|
Kudsieh B, Fernández-Vigo JI, Vila-Arteaga J, Urcola JA, Martínez-de-la-Casa JM, García-Feijóo J, Ruiz-Moreno JM, Fernández-Vigo JÁ. Update on the usefulness of optical coherence tomography in assessing the iridocorneal angle. ACTA ACUST UNITED AC 2019; 94:478-490. [PMID: 31371112 DOI: 10.1016/j.oftal.2019.06.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2019] [Revised: 06/19/2019] [Accepted: 06/20/2019] [Indexed: 10/26/2022]
Abstract
The iridocorneal angle, due to its implications in the physiopathology of aqueous humour drainage, is a fundamental structure of the anterior chamber. Anterior segment optical coherence tomography is a rapid and non-invasive technique that obtains images in vivo. The high resolution allows it to analyse the normal anatomy of the angle, any alterations, and the changes that occur after different therapeutic interventions. Anterior segment optical coherence tomography technology has evolved to provide images that allow the identification and quantification of the angular structures in healthy subjects and in glaucoma patients, and especially the trabecular meshwork and the Schlemm's canal. It also enables the angle width to be quantified, with some objective parameters that have been standardised in recent years, such as the trabecular-iris angle, the angle opening distance, and the trabecular-iris area. This technique has multiple uses in the study of the different mechanisms of angle closure, the evaluation of changes after a laser peripheral iridotomy or iridoplasty after cataract surgery, as well as after the implantation of phakic lenses.
Collapse
Affiliation(s)
- B Kudsieh
- Departamento de Oftalmología, Hospital Universitario Puerta de Hierro Majadahonda, Madrid, España; Centro Internacional de Oftalmología Avanzada, Madrid, España.
| | - J I Fernández-Vigo
- Centro Internacional de Oftalmología Avanzada, Madrid, España; Departamento de Oftalmología, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria (IdISSC), Madrid, España
| | - J Vila-Arteaga
- Hospital La Fe, Valencia, España; Clínica Vila-Innova Ocular, Valencia, España
| | - J Aritz Urcola
- Departamento de Oftalmología, Hospital Universitario de Álava, Vitoria, España; Begitek Clínica Oftalmológica, Innova Ocular, Donostia-San Sebastián, España
| | - J M Martínez-de-la-Casa
- Departamento de Oftalmología, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria (IdISSC), Madrid, España
| | - J García-Feijóo
- Departamento de Oftalmología, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria (IdISSC), Madrid, España
| | - J M Ruiz-Moreno
- Departamento de Oftalmología, Hospital Universitario Puerta de Hierro Majadahonda, Madrid, España
| | - J Á Fernández-Vigo
- Centro Internacional de Oftalmología Avanzada, Madrid, España; Departamento de Oftalmología, Universidad de Extremadura, Badajoz, España
| |
Collapse
|
24
|
Alfonso JF, Fernández-Vega-Cueto L, Alfonso-Bartolozzi B, Montés-Micó R, Fernández-Vega L. Five-Year Follow-up of Correction of Myopia: Posterior Chamber Phakic Intraocular Lens With a Central Port Design. J Refract Surg 2019; 35:169-176. [PMID: 30855094 DOI: 10.3928/1081597x-20190118-01] [Citation(s) in RCA: 52] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2018] [Accepted: 01/14/2019] [Indexed: 02/02/2023]
Abstract
PURPOSE To assess the long-term correction of moderate to high myopia using a posterior chamber phakic intraocular lens with a central port design. METHODS Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, intraocular pressure (IOP), endothelial cell density (ECD), vault, and adverse events over a 5-year period were evaluated retrospectively. RESULTS A total of 147 eyes (83 patients) were evaluated. Mean postoperative UDVA and CDVA were 0.05 ± 0.11 and 0.02 ± 0.08 logMAR at 1 year and 0.13 ± 0.18 and 0.02 ± 0.09 logMAR at 5 years, respectively. More than 95% of eyes achieved CDVA of 20/25 or better at both follow-up periods. CDVA was unchanged or improved from one to three or more lines in all eyes. Preoperatively, mean spherical equivalent (SE) was -9.20 ± 3.02 diopters (D). At 1 year, the mean SE was -0.17 ± 0.26 D, with 91.53% of eyes within ±0.50 D and 100% of eyes within ±1.00 D of the target. At 5 years, the mean SE was -0.44 ± 0.47 D, with 67.4% of eyes within ±0.50 D and 90.1% of eyes within ±1.00 D of the target. Mean IOP was 12.74 ± 1.65 and 13.0 ± 2.03 mm Hg, at 1 and 5 years, respectively. No significant rise in IOP (> 20 mm Hg) occurred during the follow-up period. Mean ECD was 2,696 ± 358 and 2,645 ± 359 cells/mm2 at 1 and 5 years, respectively, representing a non-significant loss of 0.43% from preoperative values (P = .304). Mean vault changed significantly from 398 ± 187 µm at 1 year to 340 ± 163 µm at 5 years (P < .001). No intraoperative or postoperative complications or adverse events occurred during the follow-up period. CONCLUSIONS The good long-term outcomes found in this study support the use of this lens with a central port design for the correction of moderate to high myopia. [J Refract Surg. 2019;35(3):169-176.].
Collapse
|
25
|
Abstract
The purpose of this review is to summarize preclinical and clinical data from publications appearing in the peer-reviewed scientific literature relevant to the safety and effectiveness of the EVO Implantable Collamer Lens (ICL) posterior chamber phakic refractive lens with a central port (V4c Visian ICL with KS Aquaport, STAAR Surgical, Inc.). A literature search was conducted using PubMed.gov to identify all articles relating to the EVO ICL. Articles were examined for their relevance, and the references cited in each article were also searched for additional relevant publications. On the basis of a total of 67 preclinical studies and clinical reports, including effectiveness data on 1,905 eyes with average weighted follow-up of 12.5 months and safety data on 4,196 eyes with weighted average follow up of 14.0 months, the EVO ICL is safe and effective for the correction of a broad range of refractive errors. High levels of postoperative uncorrected visual acuity, refractive predictability, and stability demonstrate the effectiveness of the EVO ICL. Safety data suggest reduced rates of anterior subcapsular cataract and pupillary block compared with earlier models. Improved safety and proven effectiveness make EVO an attractive option for surgeons and patients.
Collapse
Affiliation(s)
- Mark Packer
- Mark Packer MD Consulting, Inc., Boulder, CO, USA,
| |
Collapse
|
26
|
Fernández-Vigo JI, Marcos AC, Agujetas R, Montanero JM, Sánchez-Guillén I, García-Feijóo J, Pandal-Blanco A, Fernández-Vigo JÁ, Macarro-Merino A. Computational simulation of aqueous humour dynamics in the presence of a posterior-chamber versus iris-fixed phakic intraocular lens. PLoS One 2018; 13:e0202128. [PMID: 30102728 PMCID: PMC6089426 DOI: 10.1371/journal.pone.0202128] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2018] [Accepted: 07/27/2018] [Indexed: 11/25/2022] Open
Abstract
Purpose To compare aqueous humour (AH) dynamics in the presence of a precrystalline (Implantable Collamer Lens®; ICL) or iris-fixed (Artiflex®) phakic intraocular lens (PIOL). Methods By computational fluid dynamics simulation, AH flow was modelled through a peripheral iridotomy (PI) or central lens hole (both 360 μm) in the presence of an Artiflex or ICL lens, respectively. The impacts of AH flow were then determined in terms of wall shear stress (WSS) produced on the endothelium or crystalline lens. Effects were also modelled for different scenarios of pupil diameter (PD 3.5 or 5.5 mm), ICL vault (100, 350, 800 μm) and number of Artiflex iridotomies (1 or 2) and location (12 or 6 o’clock). Results For a PD of 3.5 mm, AH volumes flowing from the posterior to the anterior chamber were 37.6% of total flow through the lens hole (ICL) and 84.2% through PI (Artiflex). For an enlarged PD (5.5 mm), corresponding values were 10.3% and 81.9% respectively, so PI constitutes a very efficient way of evacuating AH. Central endothelial WSS in Pa was lower for the large vault ICL and the Artiflex (1−03 and 1.1−03 respectively) compared to the PIOL-free eye (1.6−03). Crystalline lens WSS was highest for the lowest vault ICL (1−04). Conclusions AH flow varied according to the presence of a precrystalline or iris-fixed intraocular lens. Endothelial WSS was lower for an implanted ICL with large vault and Artiflex than in the PIOL-free eye, while highest crystalline WSS was recorded for the lowest vault ICL.
Collapse
Affiliation(s)
- José Ignacio Fernández-Vigo
- Departamento de Oftalmología, Hospital Universitario Clínico San Carlos, Instituto de Investigación sanitaria San Carlos, Madrid (Spain)
- Centro Internacional de Oftalmología Avanzada, Madrid (Spain)
- * E-mail:
| | - Alfonso C. Marcos
- Departamento de Expresión Gráfica, Universidad de Extremadura, Badajoz (Spain)
| | - Rafael Agujetas
- Departamento de Ingeniería Mecánica, Energética y de los Materiales and Instituto de Computación científica avanzada (ICCAEx), Universidad de Extremadura, Badajoz (Spain)
| | - José María Montanero
- Departamento de Ingeniería Mecánica, Energética y de los Materiales and Instituto de Computación científica avanzada (ICCAEx), Universidad de Extremadura, Badajoz (Spain)
| | | | - Julián García-Feijóo
- Departamento de Oftalmología, Hospital Universitario Clínico San Carlos, Instituto de Investigación sanitaria San Carlos, Madrid (Spain)
| | | | - José Ángel Fernández-Vigo
- Centro Internacional de Oftalmología Avanzada, Madrid (Spain)
- Facultad de Medicina, Universidad de Extremadura, Badajoz (Spain)
| | | |
Collapse
|
27
|
Zhao J, Luo D, Sun Y, Niu L, Zhao F, Wang X, Wang H, Chen Q, Zhou X. Implanting a posterior chamber phakic intraocular lens in highly myopic eyes with peripheral primary iris and ciliary body cysts. Eur J Ophthalmol 2018; 29:171-177. [PMID: 29607656 DOI: 10.1177/1120672118766445] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE: To investigate the safety and efficacy of implanting a posterior chamber implantable collamer lens with a central hole in cases of high myopia with peripheral primary iris or ciliary body cysts. METHODS: A total of 37 eyes of 19 patients with primary iris or ciliary body cysts detected by ultrasonic biological microscope were included, with spherical powers of -10.26 ± 3.28 D and cylinder powers of -1.71 ± 1.18 D. Each patient received ultrasonic biological microscope and a routine examination before implantation of the implantable collamer lens. A routine postoperative follow-up was performed to observe changes in the iris or ciliary body cyst, ranging from 3 to 18 months. RESULTS: There were no complications. At the last follow-up, 56.8% (21/37) of eyes achieved the same corrected distance visual acuity as their preoperative measurements, 43.2% of eyes were enhanced by ≥1 line, and no patients' corrected distance visual acuity declined. The efficacy index and safety index were 0.95 and 1.11, respectively. After 18 months, 66.7% of the spherical equivalents were between ±0.5 D with 100% between ±1.0 D. The postoperative mean spherical equivalents at 1, 3, 6, 12, and 18 months were -0.45 ± 0.31 D, -0.39 ± 0.29 D, -0.36 ± 0.30 D, -0.39 ± 0.38 D, and -0.48 ± 0.23 D (p = 0.789). The vaults were 516 ± 140, 548 ± 124, 498 ± 133, 582 ± 161, and 557 ± 110 μm (p = 0.355). There were no changes in size (p > 0.05), number, or position of the iris or ciliary body cysts. CONCLUSION: Implantable collamer lens implantation is safe and effective for highly myopic patients with peripheral primary iris and ciliary body cysts. The cysts did not change after operation in this study.
Collapse
Affiliation(s)
- Jing Zhao
- 1 Key Laboratory of Myopia, Ministry of Health, Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
| | - Dongqiang Luo
- 2 Center of Ophthalmology and Optometric, People's Hospital of Hunan Province, Changsha, China
| | - Yong Sun
- 3 Department of Ophthalmology, The People's Hospital of Shajin in Baoan District, Shenzhen, China
| | - Lingling Niu
- 1 Key Laboratory of Myopia, Ministry of Health, Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
| | - Feng Zhao
- 1 Key Laboratory of Myopia, Ministry of Health, Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
| | - Xiaoying Wang
- 1 Key Laboratory of Myopia, Ministry of Health, Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
| | - Hua Wang
- 2 Center of Ophthalmology and Optometric, People's Hospital of Hunan Province, Changsha, China
| | - Qian Chen
- 1 Key Laboratory of Myopia, Ministry of Health, Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
| | - Xingtao Zhou
- 1 Key Laboratory of Myopia, Ministry of Health, Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
| |
Collapse
|
28
|
Impacts of Implantable Collamer Lens V4c Placement on Angle Measurements Made by Optical Coherence Tomography: Two-Year Follow-up. Am J Ophthalmol 2018; 186:171-172. [PMID: 29221822 DOI: 10.1016/j.ajo.2017.10.034] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2017] [Accepted: 10/31/2017] [Indexed: 11/20/2022]
|
29
|
Impacts of Implantable Collamer Lens V4c Placement on Angle Measurements Made by Optical Coherence Tomography: Two-Year Follow-up. Am J Ophthalmol 2018; 186:172-173. [PMID: 29246430 DOI: 10.1016/j.ajo.2017.10.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2017] [Revised: 10/23/2017] [Accepted: 10/25/2017] [Indexed: 11/23/2022]
|