1
|
Yadgarov A, Provencher L, Shafer B, Funke C. Adopting Interventional Glaucoma Via Sustained-Release Therapies: The Wide-Ranging Impact of Procedural Pharmaceuticals in Ophthalmology. Ophthalmol Ther 2024; 13:2825-2838. [PMID: 39384687 PMCID: PMC11493884 DOI: 10.1007/s40123-024-01041-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2024] [Accepted: 09/18/2024] [Indexed: 10/11/2024] Open
Abstract
Topical medical therapy is the most common approach to the treatment of many ocular conditions. While effective, topical therapy has numerous important limitations. Eye drops can have unpleasant or even dangerous side effects, are often difficult to self-administer, and the application of multiple drops per day, possibly from multiple different bottles, can be burdensome. Perhaps the most important limitation of topical medical therapy is non-adherence, a complex multifactorial behavior that increases the risk of poor outcomes associated with undertreatment. There is growing interest in a class of therapeutics termed "procedural pharmaceuticals" (PPs), which remove the responsibility of self-dosing from patients. An array of PPs are available for the treatment of a variety of ocular conditions, such as those for glaucoma, retina, and cataract surgery; and many more will emerge in coming years. A paradigm shift away from patient-administered therapy toward provider-administered therapy will have important implications for both providers and patients. This paper explores the impact that PPs have had, and will have, on the clinical practice of ophthalmology.
Collapse
Affiliation(s)
- Arkadiy Yadgarov
- Omni Eye Services, 5505 Peachtree Dunwoody Rd, Suite 300, Atlanta, GA, 30342, USA.
| | | | - Brian Shafer
- Shafer Vision Institute, Plymouth Meeting, PA, USA
- Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
- Lewis Katz School of Medicine, Temple University, Philadelphia, PA, USA
| | | |
Collapse
|
2
|
Stingl JV, Ortolano LC, Azuara-Blanco A, Hoffmann EM. Systematic Review of Instruments for the Assessment of Patient-Reported Outcomes and Quality of Life in Patients with Childhood Glaucoma. Ophthalmol Glaucoma 2024; 7:391-400. [PMID: 38423388 DOI: 10.1016/j.ogla.2024.02.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2023] [Revised: 02/06/2024] [Accepted: 02/20/2024] [Indexed: 03/02/2024]
Abstract
TOPIC To identify patient-reported outcome measures (PROMs) that have been used in children and adolescents with glaucoma and to evaluate their methodologic quality. CLINICAL RELEVANCE Childhood glaucoma impairs vision and quality of life (QoL) throughout all stages of life. Thus, a PROM needs to cover many different age groups and topics. Various instruments have been used to evaluate patient-reported outcomes (PROs) in patients with childhood glaucoma, however, it is unclear which PROM has the highest methodologic quality and complies best with the needs of patients with childhood glaucoma. METHODS A systematic literature review was performed searching MEDLINE (PubMed), the Cochrane Library, Web of Science, and PsycINFO (EBSCO). We included peer-reviewed full-text articles of the past 10 years in English, German, or Spanish language that reported PROMs in children with glaucoma. The study selection and methodologic quality assessment of the identified PROMs was performed by 2 independent reviewers using a 7-point checklist. The content was mapped onto the World Health Organization International Classification of Functioning, Disability and Health. The systematic review was prospectively registered in PROSPERO (ID CRD42022353936). RESULTS The search strategy retrieved 3295 matches. A total of 2901 studies were screened, and 11 relevant articles were identified using 10 different instruments. The instruments addressed functional visual ability, vision-related QoL, health-related QoL, and life satisfaction. Six instruments were applicable for the use in children. Seven of the questionnaires received the highest number of positive ratings (5/7). None of the instruments considered the views of patients with childhood glaucoma during their development. CONCLUSION This systematic review provides a descriptive catalog of vision-specific and generic health PRO instruments that have been used in childhood glaucoma cohorts. An instrument specifically developed for childhood glaucoma is lacking which might result in missing important factors, such as permanent treatment with eye drops, repeated surgeries, and heritability of the disease, when investigating the QoL in children with glaucoma. FINANCIAL DISCLOSURE(S) Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
Collapse
Affiliation(s)
- Julia V Stingl
- Department of Ophthalmology, University Medical Center of the Johannes Gutenberg-University Mainz, Mainz, Germany
| | - Lorena Cascant Ortolano
- Departmental Library, University Medical Center of the Johannes Gutenberg-University Mainz, Mainz, Germany
| | | | - Esther M Hoffmann
- Department of Ophthalmology, University Medical Center of the Johannes Gutenberg-University Mainz, Mainz, Germany.
| |
Collapse
|
3
|
Dhawale KK, Tidake P. A Comprehensive Review of Recent Advances in Minimally Invasive Glaucoma Surgery: Current Trends and Future Directions. Cureus 2024; 16:e65236. [PMID: 39184647 PMCID: PMC11342062 DOI: 10.7759/cureus.65236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2024] [Accepted: 07/24/2024] [Indexed: 08/27/2024] Open
Abstract
Glaucoma, a leading cause of blindness globally, necessitates effective management strategies to prevent irreversible vision loss. Traditional glaucoma surgeries, while effective, are associated with significant risks and complications. Minimally invasive glaucoma surgery (MIGS) has emerged as a transformative approach, offering safer and less invasive alternatives. This review provides a comprehensive overview of recent advancements in MIGS, highlighting current trends, technological innovations, and future directions. MIGS procedures, characterized by smaller incisions and quicker recovery times, have expanded the therapeutic landscape, enabling earlier intervention and improved patient outcomes. The review evaluates various MIGS techniques, their efficacy, safety profiles, and clinical outcomes, drawing insights from comparative studies and meta-analyses. Technological innovations, including enhanced device designs and integration with digital health technologies, have further bolstered the field. Despite challenges in patient selection and long-term outcomes, the future of MIGS is promising, with ongoing research and development poised to enhance its impact. By synthesizing the latest research, this review aims to inform clinicians, researchers, and policymakers, ultimately contributing to improved management of glaucoma and patient care.
Collapse
Affiliation(s)
- Kasturi K Dhawale
- Ophthalmology, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| | - Pravin Tidake
- Ophthalmology, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| |
Collapse
|
4
|
Fan Gaskin JC, Bigirimana D, Kong GYX, McGuinness MB, Atik A, Liu L, Brooks AMV, Ang GS. Prospective, Randomized Controlled Trial of Cataract Surgery vs Combined Cataract Surgery With Insertion of iStent Inject. Ophthalmol Glaucoma 2024; 7:326-334. [PMID: 38369058 DOI: 10.1016/j.ogla.2024.02.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Revised: 02/10/2024] [Accepted: 02/12/2024] [Indexed: 02/20/2024]
Abstract
PURPOSE To evaluate the efficacy and safety of combined cataract surgery with insertion of an ab interno trabecular microbypass device (iStent Inject, Glaukos Corporation) compared to cataract surgery alone in patients with mild-to-moderate glaucoma. DESIGN Prospective, randomized, assessor-masked controlled trial at a single centre. PARTICIPANTS Eyes with visually-significant cataract and mild-to-moderate glaucoma with preoperative intraocular pressure (IOP) of 12 to 30 mmHg on 0 to 3 ocular hypotensive medications. METHODS Participants eyes were randomized (2017-2020) 1:1 to combined cataract surgery with iStent Inject (treatment group, n = 56) or cataract surgery alone (control group, n = 48), and followed up for 2 years. MAIN OUTCOME MEASURES The co-primary effectiveness endpoints were the number of ocular hypotensive medications and IOP at 24-months post-surgery. The secondary effectiveness endpoints were ocular comfort as measured by the Ocular Surface Disease Index (OSDI) and vision-related quality of life as measured by the Glaucoma Activity Limitation Questionnaire (GAL-9) at 24-months. Safety measures included postoperative visual acuity, any unplanned return to the operating theatre, adverse events, and complications. RESULTS Participants (67.3% male) were aged 53 to 85 years, and treatment groups were similar in terms of mean medicated IOP (treatment group 17.7 mmHg ± 4.0; control group 17.1 mmHg ± 3.1), and number of ocular hypotensive medications (treatment group 1.69 ± 1.05; control group 1.80 ± 1.22) at baseline. At 24 months, the number of ocular hypotensive medications were 0.7 ± 0.9 in the treatment groups compared to 1.5 ± 1.9 in the control group, with an adjusted difference of 0.6 fewer medications per eye in the treatment group (95% CI 0.2-1.1, P = 0.008). In the treatment group, 57% of eyes were on no glaucoma medications compared to 36% in the control group. There was no significant difference in IOP between the 2 groups beyond the 4-weeks. There were no differences in patient-reported outcomes between the 2 groups. The visual outcomes and safety profiles were similar between the 2 groups. CONCLUSIONS Combined cataract surgery with iStent Inject achieved a clinically- and statistically-significantly greater reduction in ocular hypotensive medication usage at 24-months compared to cataract surgery alone, with no significant difference in IOP. FINANCIAL DISCLOSURE(S) Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
Collapse
Affiliation(s)
- Jennifer C Fan Gaskin
- Glaucoma Investigation and Research Unit, Royal Victorian Eye and Ear Hospital, Melbourne, Australia; Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, Melbourne, Australia; Ophthalmology, Department of Surgery, University of Melbourne, Melbourne, Australia.
| | - Deus Bigirimana
- Glaucoma Investigation and Research Unit, Royal Victorian Eye and Ear Hospital, Melbourne, Australia; Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, Melbourne, Australia
| | - George Yu Xiang Kong
- Glaucoma Investigation and Research Unit, Royal Victorian Eye and Ear Hospital, Melbourne, Australia; Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, Melbourne, Australia; Ophthalmology, Department of Surgery, University of Melbourne, Melbourne, Australia
| | - Myra B McGuinness
- Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, Melbourne, Australia; Ophthalmology, Department of Surgery, University of Melbourne, Melbourne, Australia
| | - Alp Atik
- Glaucoma Investigation and Research Unit, Royal Victorian Eye and Ear Hospital, Melbourne, Australia; Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, Melbourne, Australia
| | - Lei Liu
- Department of Ophthalmology, The Alfred Hospital, Melbourne, Australia
| | - Anne M V Brooks
- Glaucoma Investigation and Research Unit, Royal Victorian Eye and Ear Hospital, Melbourne, Australia; Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, Melbourne, Australia; Ophthalmology, Department of Surgery, University of Melbourne, Melbourne, Australia
| | - Ghee Soon Ang
- Glaucoma Investigation and Research Unit, Royal Victorian Eye and Ear Hospital, Melbourne, Australia
| |
Collapse
|
5
|
Hengerer FH, Auffarth GU, Conrad-Hengerer I. 7-Year Efficacy and Safety of iStent inject Trabecular Micro-Bypass in Combined and Standalone Usage. Adv Ther 2024; 41:1481-1495. [PMID: 38363465 PMCID: PMC10960914 DOI: 10.1007/s12325-024-02788-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Accepted: 01/17/2024] [Indexed: 02/17/2024]
Abstract
INTRODUCTION This study evaluated 7-year effectiveness and safety of second-generation trabecular micro-bypass implantation (iStent inject) either in combination with cataract surgery or as a standalone procedure (Combined or Standalone subgroups, respectively) in eyes with open-angle glaucoma. METHODS This prospective, non-randomized, unmasked, longitudinal study included 125 consecutive iStent inject cases of a single surgeon at a large German academic hospital. Patients had considerable preoperative disease burden, with mean intraocular pressure (IOP) of 23.5 mmHg, 84.8% of eyes on ≥ 2 medications, and 38.4% of eyes with prior glaucoma surgery. IOP, medications, adverse events, and secondary surgeries were assessed through 7 years in the Overall cohort and in Combined (n = 81) and Standalone (n = 44) subgroups. RESULTS Over 7-year follow-up, mean IOP decreased by 36.2-40.0% in Overall eyes, 34.1-38.9% in Combined eyes, and 39.5-43.5% in Standalone eyes (p < 0.001 at all timepoints for all groups). Meanwhile, mean medications decreased by 59.3-71.3% in Overall eyes, 57.9-69.0% in Combined eyes, and 62.1-76.2% in Standalone eyes (p < 0.001 at all timepoints in all groups). At last follow-up (mean 77.4 months; 92.8% of patients with last visit at 6 or 7 years), 83.7% of Overall eyes, 82.3% of Combined eyes, and 86.4% of Standalone eyes had achieved ≥ 20% IOP reduction vs preoperative. At last follow-up vs preoperative, 100% of eyes in all groups had the same or lower IOP and 100% had the same or lower medication regimen. Safety outcomes were favorable, with no filtration surgeries and only 4.84% of eyes experiencing clinically significant visual field loss over 7 years of follow-up. CONCLUSION iStent inject implantation with or without phacoemulsification produced significant and durable 7-year reductions in IOP (~ 34-44% reduction) and medications (~ 58-76% reduction) while preventing filtering surgery in this cohort of patients with relatively high preoperative disease burden. Combined and Standalone cases had similarly favorable effectiveness and safety.
Collapse
Affiliation(s)
- Fritz H Hengerer
- David J Apple International Laboratory of Ophthalmic Pathology, Department of Ophthalmology, International Vision Correction Research Centre (IVCRC), Buergerhospital, University of Heidelberg, Frankfurt, Germany.
- University Eye Hospital, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
| | - Gerd U Auffarth
- University Eye Hospital, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Ina Conrad-Hengerer
- University Eye Hospital, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| |
Collapse
|
6
|
Morita S, Sakanishi Y, Riyu I, Watanabe S, Ebihara N. Comparative evaluation of iStent versus iStent inject W combined with phacoemulsification in open angle glaucoma. PLoS One 2024; 19:e0297514. [PMID: 38315707 PMCID: PMC10843132 DOI: 10.1371/journal.pone.0297514] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Accepted: 12/29/2023] [Indexed: 02/07/2024] Open
Abstract
PURPOSE The study aimed to compare the 12-month post-operative outcomes of iStent and iStent inject W (inject W), and the factors associated with their success in open-angle glaucoma. METHODS This single-center, retrospective comparative case series evaluated the medical records of patients who underwent iStent (comprising 1 stent) or inject W (comprising 2 stents) implantation with cataract surgery for primary open-angle glaucoma and normal tension glaucoma between January 2019 and March 2022. The 12-month post-operative efficacy outcomes included intraocular pressure (IOP), glaucoma medications, and survival analysis of the probability of success. "Failure" was defined as any of the following conditions compared to baseline: 1) IOP elevation, 2) increased glaucoma medication, or 3) IOP decline not exceeding 20% when glaucoma medication scores were comparable, and 4) need for additional glaucoma surgery. The safety outcomes included intra- and post-operative adverse events and changes in the best-corrected visual acuity and visual field. RESULTS The study comprised 55 eyes in the iStent and 105 in the inject W groups. At 12 months, treatment success was achieved in 66.0% of iStent and 78.4% of inject W eyes. The mean IOP was lower, and the percent reduction from baseline was equal in iStent-treated eyes (8.0% reduction, 14.8 mmHg to 13.7 mmHg, P<0.01) and inject W-treated eyes (11.9% reduction, 15.0 mmHg to 13.8 mmHg, P<0.01) (between-group comparison, P = 0.23). The mean medication burden decreased significantly from 2.5 to 1.1 for iStent (55.0% reduction, P<0.01) and 2.9 to 1.7 for iStent inject (46.8% reduction, P<0.01), with no significant differences between the two groups (P = 0.17). Both devices exhibited excellent safety. CONCLUSIONS Both devices significantly reduced IOP and glaucoma medication 12 months post-operatively. The outcome measures did not differ significantly between the two groups, and lower baseline IOP was predictive of surgical failure.
Collapse
Affiliation(s)
- Shuu Morita
- Department of Ophthalmology, Juntendo University Urayasu Hospital, Tiba, Japan
| | - Yoshihito Sakanishi
- Department of Ophthalmology, Juntendo University Urayasu Hospital, Tiba, Japan
| | - Ikari Riyu
- Department of Ophthalmology, Juntendo University Urayasu Hospital, Tiba, Japan
| | - Satoshi Watanabe
- Department of Ophthalmology, Juntendo University Urayasu Hospital, Tiba, Japan
| | - Nobuyuki Ebihara
- Department of Ophthalmology, Juntendo University Urayasu Hospital, Tiba, Japan
| |
Collapse
|
7
|
Linghu W, Niu M, Sun N, Gao F, Li X, Zhang X. Development and Psychometric Properties of the Chronic Uveitis-Specific Quality of Life Instrument for Patients with Chronic Uveitis. Ocul Immunol Inflamm 2024; 32:194-202. [PMID: 36638326 DOI: 10.1080/09273948.2022.2162926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Accepted: 12/21/2022] [Indexed: 01/15/2023]
Abstract
PURPOSE To develop and assess psychometric properties of a disease-specific quality of life (QOL) assessment tool for patients with chronic uveitis. METHODS The initial 42-item chronic uveitis-related QOL questionnaire (CUQOL) was developed by literature review, semi-structured interviews, and expert consultation. Further development and assessment of the CUQOL were performed using Classic Test Theory and Rasch analysis. RESULTS The CUQOL version 1.0 was constructed with 28 items in five dimensions. The five subscales satisfied the requirements of unidimensionality, local independence, and threshold ordering. Cronbach's α coefficient for overall and each scale of the CUQOL 1.0 ranged from 0.75 to 0.94, with test-retest intraclass correlation ranging from 0.95 to 0.99. The CUQOL 1.0 has satisfactory convergent validity (r = 0.41-0.82), reasonable known group validity (p < .05), and good responsiveness (p < .05). CONCLUSIONS The CUQOL 1.0 is reliable and vaild for evaluating the QOL of patients with chronic uveitis.
Collapse
Affiliation(s)
- Wenrui Linghu
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Mingyan Niu
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Nan Sun
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Fei Gao
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Xiaorong Li
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| | - Xiaomin Zhang
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China
| |
Collapse
|
8
|
Martini K, Baillif S, Nahon-Esteve S, Denis P, Martel A. Intraoperative iStent versus postoperative selective laser trabeculoplasty in early glaucoma patients undergoing cataract surgery: A retrospective comparative study. J Fr Ophtalmol 2024; 47:103956. [PMID: 37783587 DOI: 10.1016/j.jfo.2023.03.042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 03/22/2023] [Accepted: 03/23/2023] [Indexed: 10/04/2023]
Abstract
PURPOSE To compare the efficacy and safety of iStent inject® versus 360° selective laser trabeculoplasty (SLT) in patients with early glaucoma undergoing cataract surgery. METHODS A retrospective non-randomized study was conducted in 73 eyes divided into two groups: cataract surgery+intraoperative iStent (n=40) versus cataract surgery+postoperative SLT at one month (n=33). The primary endpoint was intraocular pressure (IOP) lowering≥20% between baseline and 6 months postoperatively. The secondary endpoints were IOP lowering at 1, 6 and 12 months, and the mean number of IOP-lowering medications at 6 and 12 months. RESULTS The mean baseline IOP was 19.1 mmHg with no significant difference between groups. The mean baseline number of IOP-lowering medications was higher in the iStent group (n=1.95) compared to the SLT group (n=1.53; P=0.04). At 6 months, 18 (60%) patients in the SLT group and 20 (51%) patients in the iStent group achieved IOP lowering≥20% with no significant difference between groups (P=0.431). At 6 months, no difference in the mean number of IOP-lowering medications was found between groups (-0.92 and -0.89 in the iStent and SLT groups, respectively). Similar results were found at 12 months. CONCLUSION These results suggest similar safety and efficacy of intraoperative iStent and postoperative 360° SLT in lowering IOP and reducing glaucoma eye drops in early glaucoma patients undergoing cataract surgery. Treatment choice should be based on the ophthalmologist's experience and on the cost-benefit ratio.
Collapse
Affiliation(s)
- K Martini
- Ophthalmology Department, University Hospital of Nice, 30, voie Romaine, 06000 Nice, France.
| | - S Baillif
- Ophthalmology Department, University Hospital of Nice, 30, voie Romaine, 06000 Nice, France
| | - S Nahon-Esteve
- Ophthalmology Department, University Hospital of Nice, 30, voie Romaine, 06000 Nice, France
| | - P Denis
- Ophtalmology Department, University Hospital of La-Croix-Rousse, grande rue de la Croix-Rousse, Lyon, France
| | - A Martel
- Ophthalmology Department, University Hospital of Nice, 30, voie Romaine, 06000 Nice, France
| |
Collapse
|
9
|
Bedrood S, Berdahl J, Sheybani A, Singh IP. Alternatives to Topical Glaucoma Medication for Glaucoma Management. Clin Ophthalmol 2023; 17:3899-3913. [PMID: 38111854 PMCID: PMC10726774 DOI: 10.2147/opth.s439457] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2023] [Accepted: 11/22/2023] [Indexed: 12/20/2023] Open
Abstract
Topical glaucoma medications have favorable safety and efficacy, but their use is limited by factors such as side effects, nonadherence, costs, ocular surface disease, intraocular pressure fluctuations, diminished quality of life, and the inherent difficulty of penetrating the corneal surface. Although traditionally these limitations have been accepted as an inevitable part of glaucoma treatment, a rapidly-evolving arena of minimally invasive surgical and laser interventions has initiated the beginnings of a reevaluation of the glaucoma treatment paradigm. This reevaluation encompasses an overall shift away from the reactive, topical-medication-first default and a shift toward earlier intervention with laser or surgical therapies such as selective laser trabeculoplasty, sustained-release drug delivery, and micro-invasive glaucoma surgery. Aside from favorable safety, these interventions may have clinically important attributes such as consistent IOP control, cost-effectiveness, independence from patient adherence, prevention of disease progression, and improved quality of life.
Collapse
Affiliation(s)
| | | | - Arsham Sheybani
- John A. Moran Eye Center, University of Utah, Salt Lake City, UT, USA
- Department of Ophthalmology and Visual Sciences, Washington University in St. Louis School of Medicine, St. Louis, MO, USA
| | | |
Collapse
|
10
|
Radcliffe NM, Shah M, Samuelson TW. Challenging the "Topical Medications-First" Approach to Glaucoma: A Treatment Paradigm in Evolution. Ophthalmol Ther 2023; 12:2823-2839. [PMID: 37855977 PMCID: PMC10640619 DOI: 10.1007/s40123-023-00831-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Accepted: 09/29/2023] [Indexed: 10/20/2023] Open
Abstract
Topical glaucoma medications are effective and safe, but they have numerous well-documented limitations that diminish their long-term utility and sustainability. These limitations can include high rates of nonadherence (with associated glaucoma progression), concerning side effects, inconsistent circadian intraocular pressure (IOP) control, complex dosing regimens, difficulty with self-administration, costs, and decreased quality of life. Despite these limitations, topical medications traditionally have been first-line in the glaucoma treatment algorithm, as no other minimally invasive treatment alternatives existed. In recent years, however, novel interventional therapies-including sustained-release drug-delivery platforms, selective laser trabeculoplasty, and micro-invasive glaucoma surgery procedures-have made it possible to intervene earlier without relying on topical medications. As a result, the topical medication-first treatment approach is being reevaluated in an overall shift toward earlier more proactive interventions.
Collapse
Affiliation(s)
- Nathan M Radcliffe
- New York Eye Surgery Center, 1101 Pelham Parkway North, Bronx, NY, 10469, USA.
| | - Manjool Shah
- New York University (NYU) Langone Health, New York, NY, USA
| | - Thomas W Samuelson
- Minnesota Eye Consultants, University of Minnesota, Minneapolis, MN, USA
| |
Collapse
|
11
|
Nijm LM, Schweitzer J, Gould Blackmore J. Glaucoma and Dry Eye Disease: Opportunity to Assess and Treat. Clin Ophthalmol 2023; 17:3063-3076. [PMID: 37869041 PMCID: PMC10590113 DOI: 10.2147/opth.s420932] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Accepted: 09/07/2023] [Indexed: 10/24/2023] Open
Abstract
Dry eye disease (DED) has been found to occur at a higher prevalence in individuals with glaucoma than in individuals without glaucoma. The relationship between glaucoma and DED may be, in part, a result of glaucoma therapy. Greater number of antiglaucoma medications used and greater number of antiglaucoma eyedrops instilled per day have been associated with ocular surface disease in patients with glaucoma. Use of antiglaucoma medication has also been associated with higher levels of ocular surface inflammatory markers and ocular surface alterations. There is evidence to suggest that antiglaucoma medications with preservatives and, to some extent, antiglaucoma medication formulations without preservatives may contribute to ocular surface signs and symptoms. Trabeculectomy for glaucoma has also been associated with ocular surface signs related to DED; however, there may be benefits of trabeculectomy and other procedures for glaucoma due to reduced use of antiglaucoma medications. Patients with glaucoma with ocular surface disease have been found to have greater ocular surface symptoms, poorer vision-related quality of life, and poorer antiglaucoma medication adherence compared with patients with glaucoma without ocular surface disease. Because of the potential negative impact of DED on patients with glaucoma, patients with glaucoma may benefit from evaluation for DED. Management of DED in patients with glaucoma may include modifications to antiglaucoma medications and use of treatments for DED.
Collapse
Affiliation(s)
- Lisa M Nijm
- Warrenville EyeCare and LASIK, Warrenville, IL, USA
- Department of Ophthalmology and Visual Sciences, University of Illinois Eye and Ear Infirmary, Chicago, IL, USA
| | | | | |
Collapse
|
12
|
Zanutigh V, Galetto L, Valvecchia F, Logioco C. Ocular Surface Evaluation after Switch from Latanoprost 0.005% to Latanoprostene Bunod 0.024. J Curr Glaucoma Pract 2023; 17:205-209. [PMID: 38269264 PMCID: PMC10803279 DOI: 10.5005/jp-journals-10078-1422] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Accepted: 09/15/2023] [Indexed: 01/26/2024] Open
Abstract
Aim and background To evaluate the ocular surface of patients treated with latanoprost (LT) 0.005% who switched to latanoprostene bunod (LBN) 0.024%. Materials and methods A prospective and nonrandomized clinical study of a case series was performed, including patients with chronic open-angle glaucoma who were on previous LT-only treatment and, after a washout period, switched to LBN, with a 3-month follow-up. The main parameter to be evaluated was the ocular surface disease index (OSDI) test. In addition, best-corrected visual acuity (BCVA), intraocular pressure (IOP), biomicroscopic aspect of the ocular surface, measuring tear breakup time, fluorescein staining (grading performed on Oxford scale) and Schirmer I test were evaluated. Results A total of 36 patients (72 eyes) were included, 21 women (58.3%) and 15 men (41.7%, with a mean age of 65.6 ± 10.9 years (37-86). The initial OSDI score was 17.8 ± 12.1 and improved to 11.1 ± 10.5 (p < 0.01). From the data evaluated at biomicroscopy, an improvement was observed in the Oxford scale from 0.6 ± 0.7 to 0.2 ± 0.8 (p: 0.01), but no statistically significant changes were observed in the break-up time (BUT) and Schirmer. BCVA remained stable, as did IOP, which was initially 13.4 ± 2.1 mm Hg and, after performing the LBN treatment change, went to 13.1 ± 1.7 mm Hg. Conclusion After the change of treatment from LT 0.005% to LBN 0.024%, the patients had an improvement in the ocular surface, maintaining control of their IOP. The need to investigate possible beneficial mechanisms on the ocular surface in glaucoma patients treated with LBN, potentially related to nitric oxide, is raised. Clinical significance Patients treated with LT 0.005% who switched to LBN 0.024% had an improvement in ocular surface symptoms and signs, keeping IOP under control.Latanoprostene bunod (LBN) 0.024% may have beneficial effects on the ocular surface, which should be further studied. How to cite this article Zanutigh V, Galetto L, Valvecchia F, et al. Ocular Surface Evaluation after Switch from Latanoprost 0.005% to Latanoprostene Bunod 0.024%. J Curr Glaucoma Pract 2023;17(4):205-209.
Collapse
Affiliation(s)
- Virginia Zanutigh
- Department of Glaucoma, Centro de Ojos Quilmes, Quilmes, Buenos Aires, Argentina
| | - Leila Galetto
- Department of Glaucoma, Centro de Ojos Quilmes, Quilmes, Buenos Aires, Argentina
| | - Florencia Valvecchia
- Department of Ocular Surface, Centro de Ojos Quilmes, Quilmes, Buenos Aires, Argentina
| | - Celina Logioco
- Department of Glaucoma, Centro de Ojos Quilmes, Quilmes, Buenos Aires, Argentina
| |
Collapse
|
13
|
Latif K, Nishida T, Moghimi S, Weinreb RN. Quality of life in glaucoma. Graefes Arch Clin Exp Ophthalmol 2023; 261:3023-3030. [PMID: 37017741 DOI: 10.1007/s00417-023-06050-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2022] [Revised: 03/07/2023] [Accepted: 03/24/2023] [Indexed: 04/06/2023] Open
Abstract
BACKGROUND An essential goal of glaucoma management is to prevent a patient's visual impairment that compromises their health-related quality of life (QOL). The disease itself, in addition to the medical or surgical treatment, can have a large impact on one's life. We aim to briefly review and evaluate aspects of QOL in glaucoma. METHODS The PubMed database was utilized for the literature examination of this review. Keywords that were searched included glaucoma, quality of life, vision-related QOL (VRQOL), quality of life questionnaire, and glaucoma therapy. RESULTS The main topics identified and analyzed during the literature review stages include factors affecting VRQOL, the assessment of VRQOL using questionnaires, QOL in early and severe glaucoma, glaucoma and activities of daily living, glaucoma treatments, and new advances in clinically assessing QOL. The study findings indicate a relationship between the deterioration of visual field and the quality of life. The investigation shows that visual loss can result in a range of daily life challenges, which include compromised mental health status and difficulties with driving, reading, and recognizing people. CONCLUSION Glaucoma-induced visual field loss can significantly impact different aspects of patients' life, and several methods exist for evaluating changes in quality of life. Quality of life assessments have their limitations as they are subjective. As potential future steps, we suggest exploring technological advancements such as virtual reality to improve patient care and outcomes.
Collapse
Affiliation(s)
- Kareem Latif
- Viterbi Family Department of Ophthalmology, Hamilton Glaucoma Center, Shiley Eye Institute, University of California, 9500 Campus Point Drive, La Jolla,, San Diego, CA, 92093-0946, USA
- School of Medicine, California University of Science and Medicine, Colton, CA, USA
| | - Takashi Nishida
- Viterbi Family Department of Ophthalmology, Hamilton Glaucoma Center, Shiley Eye Institute, University of California, 9500 Campus Point Drive, La Jolla,, San Diego, CA, 92093-0946, USA.
| | - Sasan Moghimi
- Viterbi Family Department of Ophthalmology, Hamilton Glaucoma Center, Shiley Eye Institute, University of California, 9500 Campus Point Drive, La Jolla,, San Diego, CA, 92093-0946, USA
| | - Robert N Weinreb
- Viterbi Family Department of Ophthalmology, Hamilton Glaucoma Center, Shiley Eye Institute, University of California, 9500 Campus Point Drive, La Jolla,, San Diego, CA, 92093-0946, USA
| |
Collapse
|
14
|
Ang BCH, Lim SY, Betzler BK, Wong HJ, Stewart MW, Dorairaj S. Recent Advancements in Glaucoma Surgery-A Review. Bioengineering (Basel) 2023; 10:1096. [PMID: 37760198 PMCID: PMC10525614 DOI: 10.3390/bioengineering10091096] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Revised: 09/10/2023] [Accepted: 09/11/2023] [Indexed: 09/29/2023] Open
Abstract
Surgery has long been an important treatment for limiting optic nerve damage and minimising visual loss in patients with glaucoma. Numerous improvements, modifications, and innovations in glaucoma surgery over recent decades have improved surgical safety, and have led to earlier and more frequent surgical intervention in glaucoma patients at risk of vision loss. This review summarises the latest advancements in trabeculectomy surgery, glaucoma drainage device (GDD) implantation, and minimally invasive glaucoma surgery (MIGS). A comprehensive search of MEDLINE, EMBASE, and CENTRAL databases, alongside subsequent hand searches-limited to the past 10 years for trabeculectomy and GDDs, and the past 5 years for MIGS-yielded 2283 results, 58 of which were included in the final review (8 trabeculectomy, 27 GDD, and 23 MIGS). Advancements in trabeculectomy are described in terms of adjunctive incisions, Tenon's layer management, and novel suturing techniques. Advancements in GDD implantation pertain to modifications of surgical techniques and devices, novel methods to deal with postoperative complications and surgical failure, and the invention of new GDDs. Finally, the popularity of MIGS has recently promoted modifications to current surgical techniques and the development of novel MIGS devices.
Collapse
Affiliation(s)
- Bryan Chin Hou Ang
- Department of Ophthalmology, National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore 308433, Singapore
- Department of Ophthalmology, National Healthcare Group Eye Institute, Woodlands Health Campus, Singapore 737628, Singapore
| | - Sheng Yang Lim
- Department of Ophthalmology, National Healthcare Group Eye Institute, Tan Tock Seng Hospital, Singapore 308433, Singapore
| | - Bjorn Kaijun Betzler
- Department of Surgery, Tan Tock Seng Hospital, National Healthcare Group, Singapore 308433, Singapore
- Yong Loo Lin School of Medicine, National University of Singapore, Singapore 119077, Singapore
| | - Hon Jen Wong
- Yong Loo Lin School of Medicine, National University of Singapore, Singapore 119077, Singapore
| | - Michael W. Stewart
- Department of Ophthalmology, Mayo Clinic, Jacksonville, FL 32224, USA; (M.W.S.)
| | - Syril Dorairaj
- Department of Ophthalmology, Mayo Clinic, Jacksonville, FL 32224, USA; (M.W.S.)
| |
Collapse
|
15
|
Balas M, Mathew DJ. Minimally Invasive Glaucoma Surgery: A Review of the Literature. Vision (Basel) 2023; 7:54. [PMID: 37606500 PMCID: PMC10443347 DOI: 10.3390/vision7030054] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Revised: 07/24/2023] [Accepted: 08/17/2023] [Indexed: 08/23/2023] Open
Abstract
Minimally invasive glaucoma surgery (MIGS) has emerged as a novel approach in the glaucoma treatment spectrum, offering a range of diverse procedures and devices aimed at reducing intraocular pressure (IOP). MIGS can be broadly classified into several categories: those that enhance trabecular outflow (Trabectome, iStent, Hydrus Microstent, Kahook Dual Blade, high frequency deep sclerotomy, and gonioscopy-assisted transluminal trabeculotomy), those that augment suprachoroidal outflow (CyPass Microstent and iStent Supra), those that target Schlemm's canal (TRAB360 and the OMNI Surgical System, Streamline, and Ab Interno Canaloplasty), and conjunctival bleb-forming procedures (EX-PRESS Glaucoma Filtration Device, Xen Gel Stent and PreserFlo MicroShunt). MIGS is considered to have a shorter surgical time and fewer severe complications when compared to traditional glaucoma surgeries such as trabeculectomy and glaucoma drainage device implantation (Ahmed, Baerveldt, and Molteno valves). This literature review comprehensively examines the distinct MIGS devices and procedures, their underlying mechanisms, and clinical outcomes, emphasizing the importance of evaluating the efficacy and complications of each approach individually. As the field of MIGS continues to evolve, it is crucial to prioritize high-quality, long-term studies to better understand the safety and effectiveness of these innovative interventions in glaucoma management.
Collapse
Affiliation(s)
- Michael Balas
- Temerty Faculty of Medicine, University of Toronto, Toronto, ON M5S 1A8, Canada;
| | - David J. Mathew
- Donald K. Johnson Eye Institute, Krembil Research Institute, University Health Network, Toronto, ON M5T 0S8, Canada
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, ON M5T 2S8, Canada
- Department of Laboratory Medicine and Pathobiology, University of Toronto, Toronto, ON M5S 1A8, Canada
| |
Collapse
|
16
|
Sheybani A, Vera V, Grover DS, Vold SD, Cotter F, Bedrood S, Sawhney G, Piette SD, Simonyi S, Gu X, Balaram M, Gallardo MJ. Gel Stent Versus Trabeculectomy: The Randomized, Multicenter, Gold-Standard Pathway Study (GPS) of Effectiveness and Safety at 12 Months. Am J Ophthalmol 2023; 252:306-325. [PMID: 36972738 DOI: 10.1016/j.ajo.2023.03.026] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 03/16/2023] [Accepted: 03/18/2023] [Indexed: 03/28/2023]
Abstract
PURPOSE To compare effectiveness and safety of the gel stent to trabeculectomy in open-angle glaucoma (OAG). DESIGN Prospective, randomized, multicenter, noninferiority study. METHODS Patients with OAG and intraocular pressure (IOP) 15 to 44 mm Hg on topical IOP-lowering medication were randomized 2:1 to gel stent implantation or trabeculectomy. Primary end point (surgical success): percentage of patients at month 12 achieving ≥20% IOP reduction from baseline without medication increase, clinical hypotony, vision loss to counting fingers, or secondary surgical intervention (SSI) in a noninferiority test with 24% margins. Secondary end points (month 12) included mean IOP and medication count, postoperative intervention rate, visual recovery, and patient-reported outcomes (PROs). Safety end points included adverse events (AEs). RESULTS At month 12, the gel stent was statistically noninferior to trabeculectomy (between-treatment difference [Δ], -6.1%; 95% CI, -22.9%, 10.8%); 62.1% and 68.2% achieved the primary end point, respectively (P=.487); mean IOP and medication count reductions from baseline were significant (P<.001); and the IOP change-related Δ (2.8 mm Hg) favored trabeculectomy (P=.024). The gel stent resulted in fewer eyes requiring in-office postoperative interventions (P=.024 after excluding laser suture lysis), faster visual recovery (P≤.048), and greater 6-month improvements in visual function problems (ie, PROs; P≤.022). The most common AEs were reduced visual acuity at any time (gel stent, 38.9%; trabeculectomy, 54.5%) and hypotony (IOP <6 mm Hg at any time) (gel stent, 23.2%; trabeculectomy, 50.0%). CONCLUSIONS At month 12, the gel stent was statistically noninferior to trabeculectomy, per the percentage of patients achieving ≥20% IOP reduction from baseline without medication increase, clinical hypotony, vision loss to counting fingers, or SSI. Trabeculectomy achieved a statistically lower mean IOP, numerically lower failure rate, and numerically lower need for supplemental medications. The gel stent resulted in fewer postoperative interventions, better visual recovery, and fewer AEs.
Collapse
Affiliation(s)
- Arsham Sheybani
- Washington University School of Medicine (A.S.), St Louis, Missouri, USA.
| | - Vanessa Vera
- Allergan, an AbbVie company (V.V.), Irvine, California, USA
| | | | | | - Frank Cotter
- Vistar Eye Center (F.C.), Roanoke, Virginia, USA
| | - Sahar Bedrood
- Acuity Eye Group (S.B.), Arcadia, California, USA; Advanced Vision Care (S.B.), Los Angeles, California, USA
| | | | | | | | - Xuemin Gu
- AbbVie (X.G.), Madison, New Jersey, USA
| | - Mini Balaram
- Nethra Consulting LLC (M.B.), Princeton, New Jersey, USA
| | | |
Collapse
|
17
|
Kolko M, Gazzard G, Baudouin C, Beier S, Brignole-Baudouin F, Cvenkel B, Fineide F, Hedengran A, Hommer A, Jespersen E, Messmer EM, Murthy R, Sullivan AG, Tatham AJ, Utheim TP, Vittrup M, Sullivan DA. Impact of glaucoma medications on the ocular surface and how ocular surface disease can influence glaucoma treatment. Ocul Surf 2023; 29:456-468. [PMID: 37302545 DOI: 10.1016/j.jtos.2023.05.012] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 05/24/2023] [Accepted: 05/29/2023] [Indexed: 06/13/2023]
Affiliation(s)
- Miriam Kolko
- Department of Drug Design and Pharmacology, University of Copenhagen, Copenhagen, Denmark; Department of Ophthalmology, Copenhagen University Hospital, Rigshospitalet, Glostrup, Denmark
| | - Gus Gazzard
- Glaucoma Service, Moorfields Eye Hospital NHS Foundation Trust, London, UK; UCL Institute of Ophthalmology, London, UK; NIHR-Moorfields Biomedical Research Centre, London, UK
| | - Christophe Baudouin
- Centre Hospitalier National d'Ophtalmologie des Quinze-Vingts, Paris, France; Université Paris-Saclay, Versailles-Saint-Quentin-en-Yvelines, Paris, France; Institut de la Vision, Sorbonne Université, Paris, France
| | - Sofie Beier
- Royal Danish Academy - Architecture, Design, Conservation, Copenhagen, Denmark
| | - Françoise Brignole-Baudouin
- Centre Hospitalier National d'Ophtalmologie des Quinze-Vingts, Paris, France; Institut de la Vision, Sorbonne Université, Paris, France; Faculté de Pharmacie, Paris Cité université, Paris, France
| | - Barbara Cvenkel
- Department of Ophthalmology, University Medical Centre Ljubljana, Ljubljana, Slovenia; Medical Faculty, University of Ljubljana, Ljubljana, Slovenia
| | - Fredrik Fineide
- Department of Medical Biochemistry, Oslo University Hospital, Oslo, Norway
| | - Anne Hedengran
- Department of Drug Design and Pharmacology, University of Copenhagen, Copenhagen, Denmark; Department of Ophthalmology, Copenhagen University Hospital, Rigshospitalet, Glostrup, Denmark
| | - Anton Hommer
- Department of Ophthalmology, HERA Hospital, Vienna, Austria
| | | | | | | | | | - Andrew J Tatham
- Princess Alexandra Eye Pavilion and Department of Ophthalmology, University of Edinburgh, Edinburgh, UK
| | - Tor Paaske Utheim
- Department of Medical Biochemistry, Oslo University Hospital, Oslo, Norway
| | | | | |
Collapse
|
18
|
Yuasa Y, Hirooka K, Okada N, Onoe H, Murakami Y, Okumichi H, Kiuchi Y. Vision-Related Quality of Life following Combined Cataract and Minimally Invasive Glaucoma Surgery or Cataract Surgery Alone in Glaucoma Patients. J Clin Med 2023; 12:jcm12093279. [PMID: 37176719 PMCID: PMC10179390 DOI: 10.3390/jcm12093279] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Revised: 04/30/2023] [Accepted: 05/02/2023] [Indexed: 05/15/2023] Open
Abstract
This study examined glaucoma patients after undergoing combined cataract and minimally invasive glaucoma surgery (MIGS), microhook ab interno trabeculotomy and goniotomy with the Kahook Dual Blade (KDB), or cataract surgery alone, and it then evaluates their vision-related quality of life (VR-QOL) following the procedure. A total of 75 eyes of 75 consecutive glaucoma patients in this prospective cohort study underwent phacoemulsification (Phaco) or phaco and MIGS (Phaco-TLO) between October 2019 and March 2022. In all cases, the National Eye Institute Visual Function Questionnaire (VFQ-25) was used to evaluate the 20 eyes in the Phaco group and the 55 eyes in the Phaco-TLO group before and at 2 months after surgery. There was a significant increase in the visual acuity (logMAR) at 2 months post-operatively (Phaco group; 0.34 ± 0.10 to -0.07 ± 0.1, p < 0.0001, Phaco-TLO group; 0.37 ± 0.43 to 0.09 ± 0.32, p < 0.0001). The median (25-75th percentile) total VFQ scores in the Phaco group before and at 2 months after surgery were 71.1 (62.4-80.6) and 79.4 (69.0-84.0), respectively. (p = 0.006). The median (25-75th percentile) total VFQ scores in the Phaco-TLO group before and at 2 months after surgery were 69.8 (55.3-78.6) and 74.7 (65.1-83.3), respectively. (p = 0.005). Glaucoma patients who underwent not only cataract surgery alone but also combined cataract surgery and MIGS exhibited significant improvement in the VR-QOL.
Collapse
Affiliation(s)
- Yuki Yuasa
- Department of Ophthalmology and Visual Science, Hiroshima University Graduate School of Biomedical Sciences, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan
- Department of Ophthalmology, Hiroshima Prefectural Hospital, 1-5-54 Ujinakanda, Minami-ku, Hiroshima 734-8530, Japan
| | - Kazuyuki Hirooka
- Department of Ophthalmology and Visual Science, Hiroshima University Graduate School of Biomedical Sciences, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan
| | - Naoki Okada
- Department of Ophthalmology and Visual Science, Hiroshima University Graduate School of Biomedical Sciences, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan
| | - Hiromitsu Onoe
- Department of Ophthalmology and Visual Science, Hiroshima University Graduate School of Biomedical Sciences, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan
| | - Yumiko Murakami
- Department of Ophthalmology and Visual Science, Hiroshima University Graduate School of Biomedical Sciences, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan
- Department of Ophthalmology, Hiroshima Prefectural Hospital, 1-5-54 Ujinakanda, Minami-ku, Hiroshima 734-8530, Japan
| | - Hideaki Okumichi
- Department of Ophthalmology and Visual Science, Hiroshima University Graduate School of Biomedical Sciences, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan
| | - Yoshiaki Kiuchi
- Department of Ophthalmology and Visual Science, Hiroshima University Graduate School of Biomedical Sciences, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan
| |
Collapse
|
19
|
Rabiu MM, Taryam MO, Yusuf M, Maji IK. The economic impacts of cataract surgery on sustainable vision and quality of life in Katsina state. HEALTH CARE SCIENCE 2023; 2:112-119. [PMID: 38938769 PMCID: PMC11080712 DOI: 10.1002/hcs2.39] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/26/2022] [Revised: 01/22/2023] [Accepted: 02/16/2023] [Indexed: 06/29/2024]
Abstract
Background This study investigates the economic impacts of eye care interventions on the quality of life in Katsina state. Eye care intervention is a requirement for equitable and inclusive development in the state. Methods The study used a survey method and 5-point Likert scale questionnaire to collect data. A multistage sampling strategy was employed to select 300 beneficiaries from the existing beneficiaries of Noor Dubai Foundation (NDF) eye care interventions. Results The findings show that cataract surgery interventions improve economic benefits and quality of life of beneficiaries in Katsina state. The results show that productivity, income, employability, dignity and skills of beneficiaries have improved significantly after the cataract surgery. Precisely, 96.2% of the beneficiaries agree that their productivity has improved; 99.6% of the beneficiaries revealed that their income has improved; 99% of respondents evidence that their employability has improved; 90% of beneficiaries have experienced an improvement in their dignity; while 97% agreed that their skills have improved. Conclusion The implication of these findings is that poor eye health is negatively related to economic benefits and quality of life while good eye health is a vital determinant of standard of living. Without good eye health, it is hard to participate in the labour force, produce goods and earn income. Thus, the Katsina state government should further improve awareness of good eye health to mitigate preventable cases of blindness for equitable and inclusive development.
Collapse
Affiliation(s)
- Mansur M. Rabiu
- Department of Programmes and ResearchNoor Dubai FoundationDubaiUAE
| | - Manal O. Taryam
- Department of Programmes and ResearchNoor Dubai FoundationDubaiUAE
| | - Muhammad Yusuf
- Department of EconomicsAir Force Institute of TechnologyKadunaNigeria
| | | |
Collapse
|
20
|
Microinvasive glaucoma surgeries: critical summary of clinical trial data with and without phacoemulsification. Curr Opin Ophthalmol 2023; 34:146-151. [PMID: 36730753 DOI: 10.1097/icu.0000000000000923] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
PURPOSE OF REVIEW To critically summarize and examine published data from randomized controlled clinical trials (RCTs) investigating the safety and efficacy of microinvasive glaucoma surgeries (MIGS) with and without cataract surgery versus cataract surgery alone. RECENT FINDINGS Three RCTs with standardized outcomes and rigorous methodology demonstrate superiority of the iStent (Glaukos), CyPass (Alcon), and Hydrus (Alcon) MIGS devices in combination with cataract surgery versus cataract surgery alone. The trials all involved medication washouts at baseline and also after 24 months of follow-up. In each of the trials, a greater proportion of participants randomized to the combined MIGS procedures achieved at least 20% unmedicated intraocular pressure (IOP) lowering compared with cataract surgery alone. With the exception of the CyPass device, which has been voluntarily withdrawn from the market, adverse events associated with MIGS were acceptable and consistent with routine intraocular surgeries. Follow-up studies demonstrate sustained efficacy, greater probabilities of visual field preservation, increased cost-effectiveness, and enhanced quality of life associated with MIGS procedures. SUMMARY Data related to MIGS platforms for treatment of open-angle glaucoma with or without co-existing cataract supports their continued adoption in clinical practice. Future studies comparing various techniques and devices in a standardized fashion are needed.
Collapse
|
21
|
The case for standalone micro-invasive glaucoma surgery: rethinking the role of surgery in the glaucoma treatment paradigm. Curr Opin Ophthalmol 2023; 34:138-145. [PMID: 36373756 PMCID: PMC9894157 DOI: 10.1097/icu.0000000000000927] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE OF REVIEW To highlight progress in glaucoma therapy challenging the traditional medication-first approach and present evidence supporting early standalone surgery in the era of micro-invasive glaucoma surgery (MIGS). RECENT FINDINGS Medical therapy is limited by well documented poor adherence that compromises the quality of intraocular pressure reduction. Results from modern clinical trials demonstrate advantages of selective laser trabeculoplasty and MIGS procedures in terms of both IOP control and progression risk. SUMMARY The MIGS options for pseudophakic or precataractous patients are limited by regulatory rules that require the performance of some procedures only at the time of cataract surgery. These include the iStent/iStent Inject and the Hydrus implants. Nonbleb-forming procedures currently available for standalone use in eyes with mild-moderate primary open-angle glaucoma include gonioscopy-assisted transluminal trabeculotomy (which lowers IOP by 28-61% and medication use by 38-73% in various studies), trabecular ablation with the Trabectome (23-39% and 21-43%, respectively), excisional goniotomy with the Kahook Dual Blade (15-36% and 15-40%, respectively), ab interno canaloplasty (35% and 57%, respectively), and combined canaloplasty and trabeculotomy using the OMNI system (39-40% and 64-73%, respectively). For patients who would benefit from early standalone surgery, these procedures offer meaningful reductions in both IOP and medication burden.
Collapse
|
22
|
Cantor L, Lindfield D, Ghinelli F, Świder AW, Torelli F, Steeds C, Dickerson Jr JE, Nguyen DQ. Systematic Literature Review of Clinical, Economic, and Humanistic Outcomes Following Minimally Invasive Glaucoma Surgery or Selective Laser Trabeculoplasty for the Treatment of Open-Angle Glaucoma with or Without Cataract Extraction. Clin Ophthalmol 2023; 17:85-101. [PMID: 36636619 PMCID: PMC9831079 DOI: 10.2147/opth.s389406] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Accepted: 12/23/2022] [Indexed: 01/07/2023] Open
Abstract
Introduction Selective laser trabeculoplasty (SLT) and minimally invasive glaucoma surgery (MIGS) are increasingly used options for mild-to-moderate open-angle glaucoma (OAG) care. While most MIGS devices are indicated for use in combination with cataract surgery only, with phacoemulsification playing a role in lowering IOP, newer technologies can also be used as standalone glaucoma surgery. Methods This systematic literature review (SLR) aimed to assess the clinical, economic, and humanistic outcomes of MIGS and SLT for the treatment of OAG and was conducted according to PRISMA guidelines. Studies that assessed MIGS or SLT in at least one treatment arm versus any other glaucoma treatment in adults with mild-to-moderate OAG were included. Clinical, humanistic (health-related quality of life [HRQoL] and patient burden), and economic data were extracted, and the methodological quality of included studies was evaluated. Results A total of 2720 articles were screened, and 81 publications were included. Fifty-eight reported clinical outcomes. The majority assessed iStent or iStent inject (n=41), followed by OMNI (n=9), gonioscopy-assisted transluminal trabeculotomy (GATT) or the Kahook Dual Blade (KDB) (n=7), Hydrus (n=6), SLT (n=5), Xen Gel Stent (n=2), PreserFlo (n=1), and iTrack (n=1). IOP reduction was observed across prospective studies, varying from -31% to -13.7% at month 6 and from -39% to -11.4% at year 1 versus baseline. Most adverse events were transient and non-serious. Limited humanistic and economic data were identified. Conclusion Given their established efficacy and safety, there is a rationale for wider use of MIGS in mild-to-moderate OAG. Of the MIGS devices, iStent and OMNI have the largest clinical evidence base supporting their sustained effectiveness.
Collapse
Affiliation(s)
- Louis Cantor
- Eugene and Marilyn Glick Eye Institute, Indiana School of Medicine, Indianapolis, IN, USA
| | - Dan Lindfield
- Royal Surrey County Hospital, Guildford, England, UK
| | | | | | - Francesca Torelli
- Valid Insight, Macclesfield, England, UK,Correspondence: Francesca Torelli, Valid Insight, Ropewalks, Newton St, Macclesfield, SK11 6QJ, UK, Tel +44 203 750 9833 Ext 703, Email
| | | | - Jaime E Dickerson Jr
- Sight Sciences, Menlo Park, CA, USA,North Texas Eye Research Institute, University of North Texas Health Science Center, Fort Worth, TX, USA
| | - Dan Q Nguyen
- Mid-Cheshire Hospitals NHS Foundation Trust, Crewe, UK
| |
Collapse
|
23
|
Cvenkel B, Kolko M. Devices and Treatments to Address Low Adherence in Glaucoma Patients: A Narrative Review. J Clin Med 2022; 12:jcm12010151. [PMID: 36614952 PMCID: PMC9821329 DOI: 10.3390/jcm12010151] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Revised: 12/05/2022] [Accepted: 12/21/2022] [Indexed: 12/28/2022] Open
Abstract
Poor adherence to topical glaucoma medications has been linked to worse visual field outcomes in glaucoma patients. Therefore, identifying and overcoming the adherence barriers are expected to slow down the progression of disease. The most common barriers to adherence, in addition to the lack of knowledge, include forgetfulness, side effects of medications, difficulties with drop instillation and low self-efficacy. Symptoms and signs of ocular surface disease, which importantly reduce patients' quality of life, are decreased by using preservative-free topical medications. Sustained drug delivery systems using different vehicles seem promising for relieving the burden of drop administration. Currently, only the bimatoprost sustained-release intracameral implant is available for clinical use and single administration. In the era of digitalization, smart drug delivery-connected devices may aid adherence and, by sharing data with care providers, improve monitoring and adjusting treatment. Selective laser trabeculoplasty as first-line treatment delays the need for drops, whereas minimally invasive glaucoma procedures with and without devices combined with cataract surgery increase the likelihood of patients with early-to-moderate glaucoma to remain drop free or reduce the number of drops needed to control intraocular pressure. The aim of this narrative review is to present and discuss devices and treatments that may improve adherence by reducing the need for drops and side effects of medications and aiding in glaucoma monitoring. For the future, there is a need for studies focusing on clinically important outcomes, quality of life and the cost of intervention with longer post-interventional follow up.
Collapse
Affiliation(s)
- Barbara Cvenkel
- Department of Ophthalmology, University Medical Centre Ljubljana, 1000 Ljubljana, Slovenia
- Medical Faculty, University of Ljubljana, 1000 Ljubljana, Slovenia
- Correspondence:
| | - Miriam Kolko
- Department of Drug Design and Pharmacology, University of Copenhagen, 2100 Copenhagen, Denmark
- Department of Ophthalmology, Copenhagen University Hospital, Rigshospitalet, 2600 Glostrup, Denmark
| |
Collapse
|
24
|
Lima FE, Geraissate JC, Ávila MP. A multicenter prospective comparative study evaluating cataract surgery and endoscopic cyclophotocoagulation either with or without iStent inject implantation in Brazilian patients with glaucoma. Int Ophthalmol 2022; 43:1665-1676. [PMID: 36273360 PMCID: PMC10149466 DOI: 10.1007/s10792-022-02563-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Accepted: 10/10/2022] [Indexed: 11/24/2022]
Abstract
Abstract
Purpose
Compare 12-month (12 M) safety and efficacy of endoscopic cyclophotocoagulation (ECP) + cataract surgery (Group 1) versus ECP + cataract surgery + iStent inject trabecular micro-bypass implantation (Group 2) in Brazilian patients with open-angle glaucoma (OAG).
Methods
This prospective, multicenter, comparative case series included patients with OAG and cataract who were randomized to receive treatment in Group 1 or Group 2. Outcomes included mean and percent reduction versus preoperative in intraocular pressure (IOP) and number of glaucoma medications; visual acuity; occurrence of adverse events; and rate of secondary surgeries.
Results
Preoperatively, Groups 1 and 2 had similar mean IOP (mean ± standard deviation 22.1 ± 3.6 and 22.0 ± 2.5 mmHg, respectively) and mean number of medications (3.3 ± 0.6 and 3.4 ± 0.6 medications, respectively). At all follow-up timepoints through 12 M, both groups achieved significant IOP and medication reductions versus preoperative (IOP p < 0.001 and number of medications p < 0.001 for both groups). At 12 M, IOP reductions were 24.2% (Group 1) and 43.6% (Group 2) (p < 0.001); mean medication reductions were 50.2% and 71.5%, respectively. Mean postoperative IOP and number of medications were higher in Group 1 than Group 2 (IOP p < 0.01 all visits, medication p < 0.01 at 6 M and 12 M). Adverse events were generally mild and infrequent in both groups.
Conclusion
Both treatment groups (ECP + phacoemulsification, with/without iStent inject implantation) achieved significant and safe reductions in IOP and medications versus preoperative in Brazilian OAG patients. Percent reductions were significantly greater, and mean IOP and medications were significantly lower, in the group receiving iStent inject.
Clinical trial registration (CTR)
CAAE project identification #20053019.5.0000.5078. Protocol #3.587.147. Clinical Trial Database of the Federal University of Goiás, Brazil. Registration Date: September 19, 2019.
Collapse
Affiliation(s)
- Francisco E. Lima
- Federal University of Goiás, Goiânia, Brazil
- Centro Brasileiro de Cirurgia de Olhos, Avenida T-2 número 401, Setor Bueno, Goiânia, 74210-010 Brazil
| | - João C. Geraissate
- Centro Brasileiro de Cirurgia de Olhos, Avenida T-2 número 401, Setor Bueno, Goiânia, 74210-010 Brazil
- Centro Brasileiro da Visão, Brasília, Brazil
| | - Marcos P. Ávila
- Federal University of Goiás, Goiânia, Brazil
- Centro Brasileiro de Cirurgia de Olhos, Avenida T-2 número 401, Setor Bueno, Goiânia, 74210-010 Brazil
- Centro Brasileiro da Visão, Brasília, Brazil
| |
Collapse
|
25
|
Awad K, Awad R, Elkazaz H, Saleh M, Mehanna A. Applying the Health Belief Model to predict preference for surgical intervention versus medical therapy among patients with open-angle glaucoma. BMJ Open Ophthalmol 2022. [PMCID: PMC9628686 DOI: 10.1136/bmjophth-2022-001113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
ObjectiveTo determine the factors influencing patient preference of surgical intervention versus medical therapy for open-angle glaucoma based on the Health Belief Model.Methods and analysisThe study is a cross-sectional study. The study was conducted on 309 patients having open-angle glaucoma attending glaucoma clinic at Alexandria Ophthalmology Hospital, Alexandria, Egypt. The patients were subjected to an interview questionnaire comprising demographic data, patient knowledge and beliefs about glaucoma, glaucoma medications and treatment options, and patient preference of treatment modality, based on the Health Belief Model.ResultsAbout half of the patients (46%) were found to prefer surgical intervention. Patients were less knowledgeable about glaucoma, in general, but knowledge scores of patients preferring surgical intervention were significantly higher than those preferring medical therapy (Percentage Mean Score, PMS: 42.46%–37.37%, respectively). Male and female patients using more medications were significantly more likely to prefer surgical intervention (p=0.015 and p=0.003, respectively). Patients having preference for surgical intervention reported higher scores for perceived susceptibility and severity of long-term medical therapy (PMS=72.61% vs 54.62%–68.62% versus 52.83%, respectively), higher scores for perceived benefits of surgical intervention (PMS=92.90% vs 43.96%, respectively) and higher scores for self-efficacy (PMS=97.18% vs 50.37%, respectively). Meanwhile, they obtained lower scores for perceived barriers to surgical intervention (PMS=53.43% vs 86.07%, respectively).ConclusionsMale gender, increased number of used eye-drops and more knowledge about glaucoma were significantly associated with patient preference for surgical intervention. Perceived benefits and barriers and self-efficacy were the significant predictors for patient surgical interference preference.
Collapse
Affiliation(s)
- Khaled Awad
- Department of Ophthalmology, Alexandria General Ophthalmology Hospital, Alexandria, Egypt
| | - Ramy Awad
- Department of Ophthalmology, Alexandria General Ophthalmology Hospital, Alexandria, Egypt
| | - Hager Elkazaz
- Department of Clinical Pharmacology, Alexandria General Ophthalmology Hospital, Alexandria, Egypt
| | - Marwa Saleh
- Department of Clinical Pharmacology, Alexandria General Ophthalmology Hospital, Alexandria, Egypt
| | - Azza Mehanna
- Health Adminstration and Behavioural Science Department, High Institute of Public Health, Alexandria University, Alexandria, Egypt
| |
Collapse
|
26
|
Clement C, Howes F, Ioannidis A, Shiu M, Manning D, Lusthaus JA, Skalicky SE, Goodwin TW. Multicenter Effectiveness and Disease Stability Through 3 Years After iStentTrabecular Micro-Bypass with Phacoemulsification in Glaucoma and Ocular Hypertension. Clin Ophthalmol 2022; 16:2955-2968. [PMID: 36071724 PMCID: PMC9444145 DOI: 10.2147/opth.s373290] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Accepted: 08/18/2022] [Indexed: 11/25/2022] Open
Abstract
Purpose To evaluate 3-year safety and efficacy of two second-generation trabecular micro-bypass stents. (iStent inject®) with phacoemulsification. Materials and Methods This multicenter retrospective study of iStent inject implantation with phacoemulsification included data from eight surgeons across Australia. Eyes with cataract and mild to advanced glaucoma [predominantly primary open-angle (POAG), primary angle closure (PAC), or normal-tension (NTG) glaucoma] or ocular hypertension (OHT) were included. Study assessments included intraocular pressure (IOP); number of ocular hypotensive medications; proportions of eyes with 0, 1, 2, or ≥3 IOP-lowering medications; IOP ≤15 mmHg or ≤18 mmHg; visual fields (VF); retinal nerve fiber layer thickness (RNFL); central corneal thickness (CCT); intraoperative complications; adverse events; and secondary surgeries. Results A total of 273 eyes underwent surgery and had 36-month follow-up. At 36 months versus preoperative, mean IOP decreased by 15.5% (16.4±4.6 mmHg to 13.9±3.5 mmHg; p<0.001), and 70.3% of eyes achieved IOP of ≤15 mmHg (versus 49.1% preoperatively; p<0.001). The mean medication burden decreased by 68.5% (from 1.51±1.17 to 0.48±0.89 medications; p<0.001); 71.4% of eyes were medication-free (versus 21.6% preoperatively; p<0.001), while 6.2% of eyes were on ≥3 medications (versus 22.3% preoperatively; p<0.001); 96.3% of eyes maintained or reduced medications vs preoperative. Significant IOP and medication reductions occurred across glaucoma subtypes (POAG, PAC, NTG, OHT): 13–22% for IOP (p<0.05 for all) and 42–94% for medication (p<0.05 for all). Favorable safety included few adverse events; stable VF, RNFL, and CCT; and filtering surgery in only 8 eyes (2.9%) over 3 years. Conclusion In this multicenter cohort from 8 surgeons across Australia, significant IOP and medication reductions were sustained through 3 years after iStent inject implantation with phacoemulsification. Results were favorable across different glaucoma subtypes (including POAG, PAC, NTG, OHT), severities, and surgeons, thereby underscoring the real-world relevance and efficacy of iStent inject implantation for glaucoma treatment.
Collapse
Affiliation(s)
- Colin Clement
- Eye Associates, Sydney, NSW, Australia
- Fairfield Eye Surgery, Fairfield, NSW, Australia
- Glaucoma Unit, Sydney Eye Hospital, Sydney, NSW, Australia
- Discipline of Ophthalmology, The University of Sydney, Sydney, NSW, Australia
- Correspondence: Colin Clement, Eye Associates, Level 4, 187 Macquarie Street, Sydney, NSW, 2000, Australia, Tel +612 9247 9972, Email
| | - Frank Howes
- Eye & Laser Centre, Gold Coast, QLD, Australia
| | | | | | - David Manning
- Hunter Cataract & Eye Centre, Charlestown, NSW, Australia
| | - Jed A Lusthaus
- Glaucoma Unit, Sydney Eye Hospital, Sydney, NSW, Australia
- Discipline of Ophthalmology, The University of Sydney, Sydney, NSW, Australia
- Eyehaus, Sydney, NSW, Australia
| | - Simon E Skalicky
- Department of Surgery Ophthalmology, University of Melbourne, Melbourne, VIC, Australia
| | | |
Collapse
|
27
|
Birhanu G, Tegegne AS. Predictors for elevation of Intraocular Pressure (IOP) on glaucoma patients; a retrospective cohort study design. BMC Ophthalmol 2022; 22:254. [PMID: 35672680 PMCID: PMC9172002 DOI: 10.1186/s12886-022-02431-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Accepted: 04/29/2022] [Indexed: 11/10/2022] Open
Abstract
OBJECTIVE Because of the increase in the number of cases, currently, glaucoma is a significant public health issue that it leads to optic nerve damage and vision loss. High Intraocular Pressure reading indicates that the treatment given to a glaucoma patient is not sufficient/ adequate. Hence, the elevation of intraocular pressure is one of the indicators that, the therapy given to glaucoma patients under treatment is inadequate. Therefore, the main objective of the current study was to investigate predictors for the variation of elevation of IOP readings on glaucoma patients. MATERIALS AND METHODS A retrospective cohort study design was conducted on 1254 glaucoma patients, whose followed-ups were from September 2015 to August 2016 at Felege Hiwot Teaching and Specialized Hospital, North West Ethiopia. Data analysis was conducted using Statistical Analysis of Systems (SAS) software version 9.2 and AMOS software. The parameter estimation was conducted using the maximum likelihood estimation technique. RESULTS Main effects like age (β = 0.01, t-value = 0.15, p-value = 0.018), patients with normal blood pressure (β = -3.35, t-value = -2.28, p-value = 0.0263), patients without diabetics (β = -3.79, t-value = -2.47, p-value = 0.014), visiting times (β = -6.00, t-value = -5.02, p-value = 0.0001), farmer glaucoma patients (β = -6.04, t-value = 3.87, p-value = 0.0001) had significant and indirect effect for the variation of elevation of IOP on glaucoma patients. Interaction effects like visiting time with existence of diabetes, visiting time with cataract surgery significantly effected on the variable of interest. Hence, both main and interaction effects had significant effects on the variable of interest. This study had identified socio-demographic characteristics, personal/individual behaviors, and clinical factors for the variation of elevation of IOP. The findings, in the current investigation, help health staff to conduct health-related education for awareness creation. Health-related education, about the progression of glaucoma, should be conducted on patients.
Collapse
|
28
|
Kerr NM. The changing glaucoma treatment paradigm. Clin Exp Ophthalmol 2022; 50:126-127. [DOI: 10.1111/ceo.14052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Affiliation(s)
- Nathan M. Kerr
- Centre for Eye Research Australia Melbourne Victoria Australia
- Royal Victorian Eye and Ear Hospital Melbourne Victoria Australia
- Eye Surgery Associates Melbourne Victoria Australia
| |
Collapse
|
29
|
iStent inject Trabecular Micro-Bypass with or Without Cataract Surgery Yields Sustained 5-Year Glaucoma Control. Adv Ther 2022; 39:1417-1431. [PMID: 35113323 PMCID: PMC8918186 DOI: 10.1007/s12325-021-02039-4] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2021] [Accepted: 12/23/2021] [Indexed: 11/05/2022]
Abstract
Introduction This study evaluated the 5-year effectiveness and safety of iStent inject® trabecular micro-bypass with or without cataract surgery (Combined or Standalone, respectively) in patients with open-angle glaucoma (OAG). Methods This prospective longitudinal case series included consecutive iStent inject cases from a single surgeon at a large German academic hospital. Intraocular pressure (IOP), medications, safety, and indicators of disease stability through 5 years were assessed in the Overall cohort and in subgroup analyses stratified by usage (Combined or Standalone). Results Preoperative mean IOP in the Overall cohort (n = 125) was 23.5 ± 6.2 mmHg on 2.68 ± 1.02 mean medications, reducing to 14.1 ± 1.8 mmHg on 0.77 ± 0.82 medications at 5 years (40% and 71% reductions, respectively; both p < 0.001). All but 1 eye (> 99%) were on medication(s) preoperatively, but 46% were medication-free at 5 years (p < 0.001). In Combined eyes (n = 81), mean IOP decreased by 39% (22.6 mmHg to 13.8 mmHg, p < 0.001) and medications by 69% (2.52 to 0.78, p < 0.001). In Standalone eyes, mean IOP reduced by 42% (25.3 mmHg to 14.6 mmHg, p < 0.001) and medications by 75% (2.98 to 0.74, p < 0.001). At final follow-up, 83% of eyes had achieved ≥ 20% IOP reduction, and all but 1 eye (> 99%) had the same or lower IOP versus preoperative; all eyes (100%) maintained or reduced their medication burden versus preoperative. Favorable safety included 0 intraoperative complications and 0 filtration surgeries through 5 years. Long-term indicators of disease stability (visual fields, retinal nerve-fiber layer thickness, and cup:disc ratio) were unchanged over the course of 5-year follow-up. Conclusions iStent inject produced significant and durable 5-year reductions in IOP (nearly 10-mmHg reduction) and medications (nearly 2-medication reduction), with stable disease parameters over time. Combined and Standalone subgroups had similar outcomes.
Collapse
|
30
|
Wan KH, Tham CC. Comment on: Quality of Life in Primary Open-Angle Glaucoma and Cataract: An Analysis of VFQ-25 and OSDI from the iStent inject® Pivotal Trial. Am J Ophthalmol 2022; 234:327-328. [PMID: 34653353 DOI: 10.1016/j.ajo.2021.05.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2021] [Accepted: 05/17/2021] [Indexed: 11/25/2022]
|
31
|
Paletta Guedes RA, Gravina DM, Paletta Guedes VM, Chaoubah A. Standalone Implantation of 2-3 Trabecular Micro-Bypass Stents (iStent inject ± iStent) as an Alternative to Trabeculectomy for Moderate-to-Severe Glaucoma. Ophthalmol Ther 2022; 11:271-292. [PMID: 34825352 PMCID: PMC8770764 DOI: 10.1007/s40123-021-00424-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Accepted: 11/01/2021] [Indexed: 12/04/2022] Open
Abstract
INTRODUCTION This retrospective consecutive study compared standalone implantation of multiple (2-3) trabecular micro-bypass stents (iStent inject ± iStent) (Multi-Stent group) vs trabeculectomy + mitomycin C (Trab group) in moderate to severe open-angle glaucoma (OAG). METHODS Eligible patients underwent Multi-Stent or Trab surgery from 2018 to 2020 and had at least 3-month follow-up; visual field mean deviation (VF MD) - 6 dB or worse; inadequate prior response to maximum medications ± laser procedures; and had trabeculectomy as their next planned intervention. Primary effectiveness, safety-adjusted treatment success, was defined as ≥ 20% intraocular pressure (IOP) reduction on the same or fewer medications, without clinically significant safety events (severe complications, secondary surgeries, reinterventions). Secondary effectiveness included mean IOP and medications; qualified and complete attainment of target IOP (≤ 21/18/15/12 mmHg and > 6 mmHg); health-economic and quality-of-life (QoL) measures; and 2-vs-3-stent subgroup analysis. RESULTS The baseline groups (n = 70 Multi-Stent/40 Trab) were similar: mean IOP (21.1 mmHg/22.3 mmHg); medications (2.87/3.10 medications); disease stage (30%/35% severe); VF MD (- 10.1 dB/- 10.4 dB); and mean last follow-up (LFU, 13.1 months/15.7 months) (all differences non-significant). Primary effectiveness: treatment success at LFU was 62.9% vs 30.0% in Multi-Stent vs Trab eyes, respectively (p = 0.001). Secondary effectiveness: At LFU in Multi-Stent vs Trab groups, respectively: mean IOP decreased by 31% to 14.2 mmHg (p < 0.001) vs by 43% to 12.5 mmHg (p < 0.001); mean medications decreased by 51% to 1.31 medications (p < 0.001) vs by 84% to 0.43 medications (p < 0.001). Multi-Stent eyes, compared to Trab eyes, had fewer visits ± reinterventions within 3 months (3.6 vs 6.1, p < 0.001); longer time to first reintervention (12.2 months vs 4.5 months, p = 0.01); fewer total reinterventions (0.26 vs 0.75, p = 0.006); and earlier lifting of postoperative restrictions (12.6 vs 32.1 days, p < 0.001). In 2-vs-3-stent analysis, there was a trend toward more 3-stent eyes achieving target IOP than 2-stent eyes. Visual fields remained stable in both Multi-Stent and Trab eyes. CONCLUSION Implanting 2-3 trabecular micro-bypass stents was a viable alternative to trabeculectomy for moderate-to-severe OAG, with clinically appropriate IOP/medication reductions and higher safety-adjusted treatment success vs trabeculectomy.
Collapse
Affiliation(s)
- Ricardo Augusto Paletta Guedes
- Paletta Guedes Eye Institute, Juiz de Fora, Brazil.
- Federal University of Juiz de Fora, 79, Oscar Vidal Street, Juiz de Fora, MG, Brazil.
| | | | | | - Alfredo Chaoubah
- Federal University of Juiz de Fora, 79, Oscar Vidal Street, Juiz de Fora, MG, Brazil
| |
Collapse
|
32
|
Samuelson TW, Singh IP, Williamson BK, Falvey H, Katz LJ, Lee WC, Odom D, McSorley D. Reply to Comment on: "Quality of Life in Primary Open-Angle Glaucoma and Cataract: An Analysis of VFQ-25 and OSDI from the iStent inject® Pivotal Trial". Am J Ophthalmol 2022; 234:329. [PMID: 34653356 DOI: 10.1016/j.ajo.2021.09.039] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Accepted: 09/30/2021] [Indexed: 11/26/2022]
|
33
|
Sarkisian SR. Cochrane Reviews Regarding Minimally Invasive Glaucoma Surgical Techniques -Validity of Conclusions May Be Limited by Incomplete Evidence. JAMA Ophthalmol 2021; 140:206-207. [PMID: 34940786 DOI: 10.1001/jamaophthalmol.2021.5397] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
|
34
|
Bicket AK, Le JT, Li T. Review of Cochrane Reviews Regarding Minimally Invasive Glaucoma Surgical Techniques-Validity of Conclusions May Be Limited by Incomplete Evidence-In Reply. JAMA Ophthalmol 2021; 140:207. [PMID: 34940798 DOI: 10.1001/jamaophthalmol.2021.5400] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Affiliation(s)
- Amanda K Bicket
- Department of Ophthalmology and Visual Sciences, University of Michigan, Ann Arbor
| | - Jimmy T Le
- Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland
| | - Tianjing Li
- Department of Ophthalmology, University of Colorado Anschutz Medical Campus, Aurora
| |
Collapse
|
35
|
Li Q, Liu S, Yang G, Li M, Qiao P, Xue Q. Naringenin inhibits autophagy and epithelial-mesenchymal transition of human lens epithelial cells by regulating the Smad2/3 pathway. Drug Dev Res 2021; 83:389-396. [PMID: 34402084 DOI: 10.1002/ddr.21868] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 08/03/2021] [Accepted: 08/05/2021] [Indexed: 12/15/2022]
Abstract
Cataract is the number one cause of blindness in the world. Fibrosis of the lens is the main cause of cataract. Pathological epithelial-mesenchymal transition (EMT) plays an important role in the development of fibrotic cataract. Inhibition of EMT may be an effective treatment for fibrosis of lens epithelial cells. Naringin (NRG) is one of the major citrus flavonoids, which has many pharmacological properties, including anti-inflammatory and cardioprotective. However, the effect of NRG on cataract induced by abnormal fibrosis of LECs is not clear. Herein, we found NRG inhibited transforming growth factor β2 (TGFβ2)-induced SRA01/04 cell viability. Additionally, NRG inhibited TGFβ2-induced cell migration and EMT. We further noticed that NRG inhibited autophagy and Smad2/3 phosphorylation in LECs. We therefore thought Naringenin inhibited autophagy and EMT of human LECs by regulating the Smad2/3 pathway. NRG could therefore serve as a promising drug for cataract treatment.
Collapse
Affiliation(s)
- Qingnan Li
- Department of Ophthalmology, Beijing Jishuitan Hospital, Beijing, China
| | - Shuang Liu
- Department of Ophthalmology, Beijing Jishuitan Hospital, Beijing, China
| | - Guang Yang
- Department of Ophthalmology, Beijing Jishuitan Hospital, Beijing, China
| | - Mingming Li
- Department of Ophthalmology, Beijing Friendship Hospital Affiliated to Capital Medical University, Beijing, China
| | - Peng Qiao
- Department of Ophthalmology, 3201 Hospital, Hanzhong, Shanxi, China
| | - Qiang Xue
- Department of Geriatrics, Beijing Jishuitan Hospital, Beijing, China
| |
Collapse
|
36
|
Al Habash A, Otaif W. Surgical Outcomes of Combined 2nd-Generation Trabecular Microbypass (iStent Inject) and Cataract Surgery for the Treatment of Primary Open-Angle Glaucoma in the Saudi Population. Ophthalmol Ther 2021; 10:923-933. [PMID: 34351592 PMCID: PMC8589900 DOI: 10.1007/s40123-021-00380-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Accepted: 07/19/2021] [Indexed: 11/03/2022] Open
Abstract
INTRODUCTION To investigate the 24-month efficacy and safety of iStent inject trabecular microbypass system implantation combined with phacoemulsification in subjects with primary open-angle glaucoma (POAG) and concomitant cataract. METHODS This prospective, uncontrolled, interventional case series included 36 eyes (29 subjects) with POAG of mild to moderate severity and coexisting cataract that underwent combined phacoemulsification and implantation of a second-generation trabecular microbypass stent (iStent inject®). Main outcome measures involved mean intraocular pressure (IOP), number of antiglaucoma medications, and proportional analysis of eyes with IOP ≤ 18 mmHg or ≤ 15 mmHg, or with 0 or ≥ 2 glaucoma medications. Secondary outcome measures involved the cup-to-disc ratio, corrected distance visual acuity (CDVA), and adverse issues. RESULTS In 36 eyes, the mean IOP at baseline was 18.28 ± 2.87 mmHg, which decreased to 14.24 ± 1.36 (22.1%) and 14.46 ± 1.56 mmHg (20.9%) at 18 and 24 months, respectively (p < 0.001). At the last follow-up, 100% of eyes had an IOP ≤ 18 mmHg (vs. 50% preoperatively), and 75.7% of eyes had an IOP ≤ 15 mmHg (vs. 16.7% preoperatively); 58.3% of eyes achieved ≥ 20% IOP reduction from preoperative status. At baseline, eyes were treated with a mean of 2.35 ± 1.18 medications, which was reduced to 0.80 ± 1.04 (66% reduction) and 0.69 ± 0.95 medications (70.6% reduction) at 18 and 24 months, respectively (p < 0.001). At the last follow-up, 54.1% of eyes were medication-free (vs. 0% preoperatively) and 24.3% of eyes were treated with ≥ 2 medications (vs. 64.9% preoperatively). This combined procedure demonstrated an excellent safety profile with no reported intraoperative complications or adverse events; CDVA was maintained throughout the entire follow-up period. CONCLUSIONS This real-world series demonstrated that iStent inject device implantation at the time of phacoemulsification is a safe and effective method to decrease IOP and the necessity for antiglaucoma medications in patients with mild-to-moderate POAG and cataract; no associated vision-threatening complications were noted.
Collapse
Affiliation(s)
- Ahmed Al Habash
- Department of Ophthalmology, King Fahd Hospital of the University, College of Medicine, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia.
| | - Wael Otaif
- Department of Ophthalmology, King Khalid University, Abha, Saudi Arabia
| |
Collapse
|
37
|
Singh IP, Sarkisian S, Hornbeak D, Katz LJ, Samuelson T. Treatment Success Across Different Levels of Preoperative Disease Burden: Stratified Two-Year Outcomes from the Pivotal Trial of iStent inject ® Trabecular Micro-Bypass in Primary Open-Angle Glaucoma and Cataract. Clin Ophthalmol 2021; 15:3231-3240. [PMID: 34376967 PMCID: PMC8349204 DOI: 10.2147/opth.s316270] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2021] [Accepted: 06/23/2021] [Indexed: 12/28/2022] Open
Abstract
PURPOSE To examine effectiveness outcomes stratified by preoperative disease burden in the pivotal trial of iStent inject ® with cataract surgery (INJ) vs cataract surgery alone (CS). MATERIALS AND METHODS Prospective, 3:1 randomized, single-masked, concurrently-controlled, multicenter trial enrolling 505 subjects with cataract and mild-to-moderate primary open-angle glaucoma who underwent iStent inject implantation with phacoemulsification or phacoemulsification alone, and were followed for 2 years including annual medication washouts. Post hoc stratification was completed for baseline mean diurnal intraocular pressure (BL DIOP; Low-DIOP <25mmHg, Mid-DIOP ≥25 to <30 mmHg, High-DIOP ≥30mmHg) and preoperative medication burden (Low-Med 1 medication, Mid-Med 2 medications, High-Med ≥3 medications). RESULTS The 24-month primary and secondary effectiveness endpoints were met, with significant treatment-over-control differences in percent of eyes achieving ≥20% unmedicated DIOP reduction and in unmedicated DIOP reduction, respectively. In subgroup analyses, the proportions of INJ eyes achieving the primary endpoint remained steady across all BL DIOP (75.4%, 77.1%, 74.4% in Low/Mid/High-DIOP strata, respectively) and preoperative medication levels (76.8%, 70.8%, 79.7% in Low/Mid/High-Med strata, respectively); meanwhile, the proportions of CS eyes diminished with higher BL DIOP (64.5%, 63.6%, 33.3%, respectively) and more medications (69.0%, 63.3%, 29.4%, respectively). Regarding secondary effectiveness, postoperative DIOP reduction increased with higher BL DIOP in INJ eyes (6.2mmHg, 7.8mmHg, 9.8mmHg, respectively) but plateaued in CS eyes (5.2mmHg, 5.8mmHg, 5.4mmHg, respectively). INJ eyes also had consistent DIOP reduction regardless of preoperative medication burden (6.8mmHg, 6.7mmHg, 7.8mmHg, respectively), while DIOP reduction diminished with more medications in CS eyes (6.1mmHg, 5.0mmHg, 3.3mmHg, respectively). Safety was favorable, comparable to phacoemulsification alone. CONCLUSION Significant IOP reductions occurred across all levels of BL DIOP and preoperative medication burden in iStent inject eyes. DIOP reductions increased with higher BL DIOP and remained stable across all levels of preoperative medication burden, suggesting the device's potential utility in more medically challenging cases.
Collapse
Affiliation(s)
| | | | | | - L Jay Katz
- Glaukos Corporation, San Clemente, CA, USA
- Wills Eye Hospital, Philadelphia, PA, USA
| | | |
Collapse
|