1
|
Thaden F, Hötzel L, Sabbagh H, Mertmann M, Wichelhaus A. In Vitro Investigation Using a New Biomechanical Force-Torque Analysis System: Comparison of Conventional and CAD/CAM-Fixed Orthodontic Retainers. MATERIALS (BASEL, SWITZERLAND) 2024; 17:4916. [PMID: 39410487 PMCID: PMC11477892 DOI: 10.3390/ma17194916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/10/2024] [Revised: 10/04/2024] [Accepted: 10/07/2024] [Indexed: 10/20/2024]
Abstract
(1) Background: After more than a decade since their first description, Inadvertent Tooth Movements (ITMs) remain an adverse effect of orthodontic retainers without a clear etiology. To further investigate the link between ITMs and the mechanical properties of different retainers, the response upon vertical loading was compared in three retainer types (two stainless steel and one nickel-titanium). The influence of different reference teeth was also considered. (2) Methods: Three retainers (R1, R2, R3) were tested in a newly developed biomechanical analysis system (FRANS). They were bonded to 3D-printed models of the lower anterior jaw and vertically displaced up to 0.3 mm. Developing forces and moments were recorded at the center of force. (3) Results: The vertical displacement caused vertical forces (Fz) and labiolingual moments (My) to arise. These were highest in the lateral incisors (up to 2.35 ± 0.59 N and 9.27 ± 5.86 Nmm for R1; 1.69 ± 1.06 N and 7.42 ± 2.65 Nmm for R2; 3.28 ± 1.73 N and 15.91 ± 9.71 Nmm for R3) for all analyzed retainers and with the R3 retainer for all analyzed reference teeth, while the lowest Fz and My values were recorded with the R1 retainer. (4) Conclusions: Displacements of 0.2 mm and larger provided forces and moments which could be sufficient to cause unwanted torque movements, such as ITMs, in all analyzed retainers. Clinicians must be mindful of these risks and perform post-treatment checkups on patients with retainers of all materials.
Collapse
Affiliation(s)
| | | | | | | | - Andrea Wichelhaus
- Department of Orthodontics and Dentofacial Orthopedics, LMU University Hospital, LMU Munich, Goethestrasse 70, 80336 Munich, Germany; (F.T.); (L.H.); (H.S.); (M.M.)
| |
Collapse
|
2
|
Jasim ES, Kadhum AS. Poly-ether-ether-ketone (PEEK) versus dead-soft coaxial bonded retainers: a randomized clinical trial. Part 1. Stability, retainer failure, and participant satisfaction. Eur J Orthod 2024; 46:cjae044. [PMID: 39206494 DOI: 10.1093/ejo/cjae044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/04/2024]
Abstract
BACKGROUND Poly-ether-ether-ketone (PEEK) was introduced in dentistry as an alternative to metal alloys. OBJECTIVE To assess the effectiveness of PEEK-fixed retainers in preserving the stability of mandibular anterior and participant satisfaction as compared to the Dead-soft coaxial fixed retainer (DSC). TRIAL DESIGN A single-centre, two-arm parallel groups randomized clinical trial. METHODS The patients treated with pre-adjusted orthodontic appliances who have a Little's Irregularity Index (LII) ≤ 0.5 mm have been enrolled in the trial. PEEK retainers were prepared to round 0.8 mm wire by computer-aided design and manufacturing, and the DSC wire was carefully adapted to the lingual surface of the lower anterior teeth. The primary outcome was the stability of lower anterior teeth as assessed by LII, while the secondary outcomes were changes in occlusal parameters, retainer failure, and patient satisfaction. The data were collected at the debonding stage (T0), 1 month (T1), 3 months (T3), and 6 months (T6) after starting the trial, except for patient's satisfaction, which was recorded using an electronic form at T1 and T6. BLINDING Single blinding of participants. RESULTS A total of 46 participants with an age range of 12-28 years old were randomly allocated to the two groups (n = 23 in each). Only one participant dropped out; therefore, 45 participants were analysed. The DSC group showed a significant increase in LII at T3. Both retainer groups had comparable occlusal measurements, failure frequency, and survival time, with no significant difference. The patients in the DSC group reported a statistically significant perception of change in the position of their teeth compared to those in the PEEK group. HARMS No harmful effects have been reported. LIMITATIONS Limited follow-up duration and the inability to blind the operator due to the nature of the intervention. CONCLUSIONS After 6-month retention, the PEEK retainer was equally effective to DSC retainers in maintaining the teeth alignment, with no significant differences regarding the failure frequency, survival rate, and general patient satisfaction. TRIAL REGISTRATION https://register.clinicaltrials.gov. (NCT05557136).
Collapse
Affiliation(s)
- Esraa Salman Jasim
- Department of Orthodontics, College of Dentistry, University of Baghdad, Bab Al Muadham, Baghdad, Iraq
| | - Ammar Salim Kadhum
- Department of Orthodontics, College of Dentistry, University of Baghdad, Bab Al Muadham, Baghdad, Iraq
| |
Collapse
|
3
|
Cui FP, Park JJ, Kim SH. Accuracy of lingual fixed retainers fabricated using a CAD/CAM bending machine. Korean J Orthod 2024; 54:257-263. [PMID: 39048921 PMCID: PMC11270144 DOI: 10.4041/kjod24.078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2024] [Revised: 06/29/2024] [Accepted: 07/11/2024] [Indexed: 07/27/2024] Open
Abstract
Objective Lingual fixed retainers, made from 0.0175-inch 3-strand twisted stainless steel wire (TW) and 0.016 × 0.022-inch straight rectangular wire (RW), are generally used in clinical practice. This study aimed to calculate their accuracy by comparing the discrepancy between computer-aided customized retainers made from these two types of wires. Methods Eleven orthodontic patients were selected, resulting in 22 maxillary and mandibular three-dimensional printing dental models. Two types of lingual fixed retainers were bonded from canine to canine. To determine the accuracy, five points were chosen for each model, resulting in 110 selected points. The absolute values of the distances on the x-, y-, and z-axes were measured to compare the accuracy of the two types of computer-aided retainers. Results The accuracy of the two types of retainers did not differ significantly in the x- and z-axes, but only in the y-axis (P < 0.01), where RW-fixed retainers exhibited a slightly but significantly increased distance compared to the TW. Conclusions Both types of retainers showed high accuracy; however, RW had a slight but statistically significant difference along the y-axis compared with TW. This type of computer-aided design/computer-aided manufacturing bending machine is limited to two dimensions, and the dental arch is curved. Therefore, RW may require slight manual adjustment by the practitioner after manufacturing.
Collapse
Affiliation(s)
- Fu Ping Cui
- Department of Orthodontics, School of Dentistry, Kyung Hee University, Seoul, Korea
| | - Jung-Jin Park
- Department of Orthodontics, School of Dentistry, Kyung Hee University, Seoul, Korea
| | - Seong-Hun Kim
- Department of Orthodontics, School of Dentistry, Kyung Hee University, Seoul, Korea
| |
Collapse
|
4
|
Murugaiyan S, Pottipalli Sathyanarayana H, Thakkar D, Padmanabhan S. Post-treatment stability, survival time and periodontal health associated with vacuum-formed, bonded and rapid prototype retainers: A prospective clinical study. J Orthod 2024:14653125241255702. [PMID: 38859624 DOI: 10.1177/14653125241255702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/12/2024]
Abstract
BACKGROUND New technologies have paved the way for newer fabrication techniques, such as rapid prototyping, which has gained popularity in the fabrication of several orthodontic appliances including retainers. AIM To evaluate the stability, survival time and periodontal health associated with vacuum-formed retainers (VFRs), bonded retainers (BRs) and rapid prototype retainers (RPRs) over a period of 12 months in retention. STUDY DESIGN Prospective clinical study. METHODS A total of 72 participants completing fixed orthodontic treatment were allocated to the following three groups by the investigators based upon their initial malocclusion, compliant and preferences: VFR; BR; and RPR. The primary outcome was Little's Irregularity Index (LII). Other stability parameters, including arch length (AL), inter-canine width (ICW) and inter-molar width (IMW), were also assessed immediately after debonding (T0) and 12 months (T2) after debonding. In addition, survival time, and calculus index and gingival index (GI) were assessed. RESULTS LII showed a significant difference (P = 0.00) between the groups and was increased in the VFR group (0.18 ± 0.22 mm) compared to the BR (0.03 ± 0.05 mm) and RPR (0.01 ± 0.03 mm) groups but was not clinically significant. The mean survival time of maxillary retainers was longest for the RPR group (220.63 days; 95% confidence interval [CI] = 194.1-247.16) but there was no significant difference between the three groups (P = 0.43). The mean survival time of mandibular retainers was higher and the same for the VFR and RPR groups (240 days; 95% CI = 240-240) and there was no significant difference between the three groups (P = 0.38). The calculus index score (P = 0.00) was statistically significant between the groups, with an increased score for the BR group (0.33 ± 0.27) compared to the VFR (0.07 ± 0.16) and RPR (0.13 ± 0.22) groups. Similarly, the GI score (P = 0.02) was statistically significant between the groups and was increased in the BR group (0.01 ± 0.19) compared to the VFR (-0.15 ± 0.18) and RPR (-0.06 ± 0.15) groups. The increase in calculus index and GI scores for the BR group were not clinically significant. CONCLUSION There were no clinically significant differences between the three retainer groups in terms of stability, periodontal health and time to failure.
Collapse
Affiliation(s)
- Sureka Murugaiyan
- Department of Orthodontics and Dentofacial Orthopaedics, Sri Ramachandra Dental College and Hospital, Sri Ramachandra Institute of Higher Education and Research, Chennai, India
| | - Haritha Pottipalli Sathyanarayana
- Department of Orthodontics and Dentofacial Orthopaedics, Sri Ramachandra Dental College and Hospital, Sri Ramachandra Institute of Higher Education and Research, Chennai, India
| | - Digant Thakkar
- Private Practice Silver Smile Dental Specialists, Product Specialist Digant's 3D Orthodontics, Rajkot, Gujarat, India
| | - Sridevi Padmanabhan
- Department of Orthodontics and Dentofacial Orthopaedics, Sri Ramachandra Dental College and Hospital, Sri Ramachandra Institute of Higher Education and Research, Chennai, India
| |
Collapse
|
5
|
Jasim ES, Kadhum AS, Hasan I. Keeping the teeth in line: Exploring the necessity of bonded retainers in orthodontics: A narrative review. J Orthod Sci 2024; 13:20. [PMID: 38784083 PMCID: PMC11114454 DOI: 10.4103/jos.jos_159_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 01/15/2024] [Accepted: 01/28/2024] [Indexed: 05/25/2024] Open
Abstract
In most recent studies, long-term retention after orthodontic treatment has been hypothesized that may be necessary to maintain the stability of the dentition and avoid post-treatment changes. The bonded fixed retainer is characterized by its clinical effectiveness, patient acceptance, and lack of patient complaints as compared with a removable retainer. An electronic database (such as PubMed, PubMed Central, Web of Science, Science Direct, Cochrane Library, Scopus, and ResearchGate) has been collected using specific keywords. Of the 152 articles, only randomized clinical trials that investigated different types of fixed retainers or compared fixed with removable retainers were illustrated in tables and included in this review. The present review has gone some way towards enhancing our understanding of the bonded fixed retainer, types, material, bonding methods, and how to improve its the success rate, besides the importance of new technology in fixed orthodontic retention.
Collapse
Affiliation(s)
- Esraa S. Jasim
- Department of Orthodontic, College of Dentistry, University of Baghdad, Iraq
| | - Ammar S. Kadhum
- Department of Orthodontic, College of Dentistry, University of Baghdad, Iraq
| | - Istabrak Hasan
- Department of Prosthetic Dentistry, Preclinical Education and Materials Science, Dental School, University of Bonn, Welschnonnenstr. 17, 53111 Bonn, Germany
| |
Collapse
|
6
|
Namura Y, Pullisaar H, Holm HV, Syverud M, Mulic A, Vandevska-Radunovic V. Elemental composition, corrosion resistance and mechanical properties of computer-aided design and computer-aided manufacturing fixed retainers versus conventional fixed retainers. J Oral Sci 2024; 66:107-110. [PMID: 38403676 DOI: 10.2334/josnusd.23-0303] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/27/2024]
Abstract
PURPOSE To investigate the elemental composition, corrosion resistance, and mechanical properties of computer-aided design and computer-aided manufacturing (CAD-CAM) retainers versus conventional fixed retainers (FRs). METHODS Eight different retainer wires were investigated. Energy dispersive X-ray spectroscopy was used to determine the elemental composition. Leakage was analysed according to ISO 10271:2020 guidelines. Hardness was tested using the Vickers method with a load of 0.3 kg. The tensile force and tensile strength were evaluated. Multiple comparisons among wires of hardness, tensile force, and strength were conducted using the Welch t-test, with Bonferroni correction. RESULTS Nickel was present in all wires. The CAD-CAM-FR wire, which contained more nickel than the other wires, had no measurable leakage. The gold-plated wires had the highest total leakage, but did not exceed the ISO standard limit. The hardness of the stainless-steel twisted wires was the highest and that of the CAD-CAM-FR wire was the lowest. The tensile strength of the CAD-CAM-FR wire was significantly lower than that of the other wires and similar to the other twisted-wire retainers. CONCLUSION The CAD-CAM-FR wire is likely to have high corrosion resistance and flexibility due to its low hardness.
Collapse
Affiliation(s)
- Yasuhiro Namura
- Department of Orthodontics, Nihon University School of Dentistry
| | - Helen Pullisaar
- Section of Orthodontics, Institute of Clinical Dentistry, Faculty of Dentistry, University of Oslo
| | | | | | | | | |
Collapse
|
7
|
Çokakoğlu S, Adanur-Atmaca R, Çakır M, Öztürk F. Stability and failure rate during 3 years of fixed retention: A follow-up of an randomized clinical trial on adolescents with four different lingual retainers. Orthod Craniofac Res 2024; 27:251-258. [PMID: 37786933 DOI: 10.1111/ocr.12714] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 08/11/2023] [Accepted: 09/12/2023] [Indexed: 10/04/2023]
Abstract
OBJECTIVE To evaluate stability outcomes and failure rates associated with four types of lingual retainers: (1) dead-soft wire, (2) multistrand stainless steel (SS) wire, (3) CAD/CAM nitinol, and (4) connected bonding pads (CBPs) after 3 years of retention. METHODS This study enrolled 96 patients (66 females, 30 males) with a median age of 19 years with four types of lingual retainers: (1) 0.016 × 0.022-inch dead-soft wire, (2) 0.0215-inch five-strand SS wire, (3) 0.014 × 0.014-inch CAD/CAM nitinol wire, and (4) CBPs. The irregularity index, intercanine distances, and arch lengths were obtained and used to evaluate mandibular stability. Failure rates were also assessed during this study. Data were statistically analysed. RESULTS Irregularity increased, whereas intercanine width and arch length decreased after 3 years of retention. The greatest irregularity was associated with the CBPs and the least with the CAD/CAM retainers. Changes in stability measurements were significantly higher in the dead-soft wire and CBPs than those in the CAD/CAM nitinol and multistrand SS wires. Parallel to these changes, the frequency of failure yielded similar results with the same significance between the groups. The failure rate of CBPs, in contrast to the CAD/CAM nitinol and multistrand SS wires, was significantly higher in the right quadrant (P < .05). CONCLUSION After taking the 3-year results into consideration, CAD/CAM nitinol and multistrand SS wires were found to be more successful than the others in maintaining mandibular stability. The most failures were observed with CBPs after 3 years of retention.
Collapse
Affiliation(s)
- Serpil Çokakoğlu
- Department of Orthodontics, Faculty of Dentistry, Pamukkale University, Denizli, Turkey
| | | | - Merve Çakır
- Department of Orthodontics, Faculty of Dentistry, Pamukkale University, Denizli, Turkey
| | | |
Collapse
|
8
|
Ntovas P, Gogolas N, Gogolas G, Mougiou E, Papazoglou E. Tooth Splinting: Implementing a 3D-printed Guide with Pre-defined Composite Resin Reservoirs: A Digital Workflow. Oper Dent 2024; 49:5-10. [PMID: 38058017 DOI: 10.2341/23-069-t] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/18/2023] [Indexed: 12/08/2023]
Abstract
The integration of digital technologies in dentistry has led to the development of various techniques to facilitate tooth splinting. In the present digital workflow, the advantages of the virtual treatment plan were combined with the versatility of the commercially available tooth splinting materials. An intraoral scanner was utilized to digitize both arches along with the patient's occlusion, eliminating the need for models from physical impressions. A template based on the virtual design of the splint was 3D-printed and served as a guide to individualize a twisted wire. The bent wire was transferred and bonded, using a 3D-printed template with pre-defined reservoirs for the composite resin. Digital technology has been implemented for tooth splinting, by fabricating a splint after its virtual design. However, the digital fabrication of the metal splints is available for limited splinting materials and the service is only provided by specific centers around the world.
Collapse
Affiliation(s)
- P Ntovas
- *Panagiotis Ntovas, DDS, MSc, scientific associate, Department of Operative Dentistry, National and Kapodistrian, University of Athens, Greece
| | - N Gogolas
- Nikolaos Gogolas, DDS, private practice, Athens, Greece
| | - G Gogolas
- George Gogolas, DDS, private practice, Athens, Greece
| | - E Mougiou
- Eleni Mougiou, DDS, private practice, Athens, Greece
| | - E Papazoglou
- Efstatios Papazoglou, DDS, MSc, PhD, Department of Operative Dentistry, National and Kapodistrian, University of Athens, Greece
| |
Collapse
|
9
|
Koller S, Niederau C, Azraq I, Craveiro RB, Knaup I, Wolf M. Low translational and rotational movements with 2-point stainless-steel retainers over a period of 1 and 3 years. J Orofac Orthop 2023:10.1007/s00056-023-00505-y. [PMID: 38153533 DOI: 10.1007/s00056-023-00505-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2022] [Accepted: 10/25/2023] [Indexed: 12/29/2023]
Abstract
OBJECTIVES Long-term stabilization of orthodontic treatment outcomes is an everyday challenge in orthodontics. The use of permanently attached lingual retainers has become gold standard. However, in some cases, patients with fixed lingual retainers show retainer-associated side effects. Aiming to reduce these side effects, clinical knowledge about how tooth and arch form stability adaption takes place over time is important to improve long-term retention protocols. Therefore, the present study aimed to investigate occlusion stability and risks for a newly developing malocclusion in a time-dependent manner in patients being treated with permanent 2‑point steel retainers. MATERIALS AND METHODS In this retrospective cohort study, a total of 66 consecutive patients with round stainless-steel retainers were analyzed for postorthodontic occlusion changes after 1 year (group 1, n = 33) and 3 years (group 2, n = 33). Digital Standard Tessellation Language (STL) datasets of the lower jaw were obtained before retainer insertion (T0), and after a 1- (T1) or 3‑year (T2) retention period. Using superimposition software, T1 and T2 situations were compared to T0 regarding rotational and translational changes in tooth positions in all three dimensions. RESULTS Occlusion changes were low in both groups. The investigated lower canines were nearly stable in the 1‑ and 3‑year group, although a retention-time-dependent increase in tooth position change of the central and lateral incisors could be observed. CONCLUSION The present data provide evidence for time-dependent development of posttherapeutic occlusal adaption limited to central and lateral incisors in patients treated with a 2-point retainer. The observed occlusal changes should be interpreted as an occlusal adaption process rather than severe posttreatment changes associated with the orthodontic retainer.
Collapse
Affiliation(s)
- Sarah Koller
- Department of Orthodontics, Dental Clinic, University Hospital RWTH Aachen, Pauwelsstr. 30, 52074, Aachen, Germany
- Orthodontic Specialist Practice Dr. Inge Kiegel-Koller, Bergheim, Germany
| | - Christian Niederau
- Department of Orthodontics, Dental Clinic, University Hospital RWTH Aachen, Pauwelsstr. 30, 52074, Aachen, Germany.
| | - Irma Azraq
- Department of Orthodontics, Dental Clinic, University Hospital RWTH Aachen, Pauwelsstr. 30, 52074, Aachen, Germany
| | - Rogerio Bastos Craveiro
- Department of Orthodontics, Dental Clinic, University Hospital RWTH Aachen, Pauwelsstr. 30, 52074, Aachen, Germany
| | - Isabel Knaup
- Department of Orthodontics, Dental Clinic, University Hospital RWTH Aachen, Pauwelsstr. 30, 52074, Aachen, Germany
| | - Michael Wolf
- Department of Orthodontics, Dental Clinic, University Hospital RWTH Aachen, Pauwelsstr. 30, 52074, Aachen, Germany
| |
Collapse
|
10
|
Padula T, Wilhelmsson T, Naoumova J. Failure frequency of fixed mandibular retainers after pre-treatment of the enamel surface with pumice versus sandblasting-a randomized controlled trial. Eur J Orthod 2023; 45:637-644. [PMID: 37032532 DOI: 10.1093/ejo/cjad010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/11/2023]
Abstract
BACKGROUND/OBJECTIVES To compare retainer survival, periodontal health, and caries implications of fixed lower retainers bonded after pre-treatment of the enamel surface with either pumice or sandblasting. TRIAL DESIGN Two-arm parallel-group, two-center randomized controlled clinical trial. METHODS One hundred sixty patients (101 females, 59 males, mean age: 17.9) requiring mandibular retainers were consecutively recruited. Patients were randomly allocated to have pre-treatment of the enamel surface with either pumice (n = 80) or sandblasting (n = 80). The primary outcome was retainer survival at 3 (T1) and 12 months (T2) control. Secondary outcomes were carious lesions and periodontal health: plaque index (PI), gingival index (GI), calculus index (CI), and probing depth (PD). The randomization sequence was generated using an online randomization and allocation concealment was secured by contacting the sequence generator for treatment assignment. Blinding was not possible at T0 due to the nature of the intervention. Statistical analyses were carried out using the t-test, Fisher's exact test, repeated measure analysis of variance, and log rank test. RESULTS Overall, the risk of bonding failure at T1 was 6.7 per cent and at T2 6.9 per cent. There were no statistically significant differences in failure rate between the two groups, neither at T1 (P = 1.000) nor at T2 (P = 0.360). No statistically significant differences were found for the intercanine periodontal indices GI, PI, CI, PD, and caries between the two groups at T0 and T1. At T2, significantly more gingivitis and plaque were seen in the sandblasting group (P = 0.05 and P = 0.047, respectively) compared with the pumice group. Calculus increased during the follow-up period in both groups (P ≤ 0.001) as well as plaque levels (P ≤ 0.001 and P = 0.025, respectively). No harm was reported. CONCLUSIONS Enamel sandblasting prior to bonding mandibular retainers is not better at preventing bonding failure. REGISTRATION 275767 (https://www.researchweb.org/is/sverige).
Collapse
Affiliation(s)
- Tommaso Padula
- Specialist Clinic of Orthodontics, Public Dental Service, Gothenburg, Region Västra Götaland, Sweden
| | - Teresia Wilhelmsson
- Specialist Clinic of Orthodontics, Public Dental Service, Alingsås, Region Västra Götaland, Sweden
| | - Julia Naoumova
- Specialist Clinic of Orthodontics, Public Dental Service, Gothenburg, Region Västra Götaland, Sweden
- Department of Orthodontics, Institute of Odontology, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| |
Collapse
|
11
|
Koller S, Craveiro RB, Niederau C, Pollak TL, Knaup I, Wolf M. Evaluation of digital construction, production and intraoral position accuracy of novel 3D CAD/CAM titanium retainers. J Orofac Orthop 2023; 84:384-391. [PMID: 35357509 PMCID: PMC10587025 DOI: 10.1007/s00056-022-00393-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2021] [Accepted: 02/22/2022] [Indexed: 10/18/2022]
Abstract
OBJECTIVES New opportunities have arisen to manufacture three-dimensional computer-aided design/computer-aided manufacturing (3D CAD/CAM) retainers from titanium blocks by digital cutting technology. These novel technologies need to fulfill requirements regarding digital planning and position accuracy. The aim of the present study was to investigate the digital construction, the CAD/CAM production and the intraoral positioning accuracy of custom-manufactured novel 3D CAD/CAM titanium retainers. MATERIALS AND METHODS A total of 37 prime4me® RETAIN3R (Dentaurum, Ispringen, Germany) retainers were inserted to stabilize the upper anterior front teeth. Following insertion, an intraoral scan was used to record the position. The intraoral position was compared to the virtual setup using 3D superimposition software. Measurement points were evaluated in all three dimensions (horizontal, sagittal and vertical planes). Data were analyzed using Kruskal-Wallis test followed by Dunn's multiple comparison test. RESULTS A total of 185 measurements were performed. The horizontal plane and the sagittal plane demonstrated a high level of positioning accuracy between the planned and the intraoral position. Statistically significant deviations between the preceding virtual setup and the intraoral situation were observed in the vertical dimension. Within the retainer, the intraoral positioning accuracy decreased for the measurement points in the direction of the distal retainer segment. CONCLUSION Based on the results, the present study shows a high level of congruence between the 3D virtually planning and the final intraoral position of the fabricated novel 3D CAD/CAM titanium retainers.
Collapse
Affiliation(s)
- S Koller
- Department of Orthodontics, Dental Clinic, University Hospital RWTH Aachen, Pauwelsstr. 30, 52074, Aachen, Germany
| | - R B Craveiro
- Department of Orthodontics, Dental Clinic, University Hospital RWTH Aachen, Pauwelsstr. 30, 52074, Aachen, Germany.
| | - C Niederau
- Department of Orthodontics, Dental Clinic, University Hospital RWTH Aachen, Pauwelsstr. 30, 52074, Aachen, Germany
| | - T L Pollak
- Department of Orthodontics, Dental Clinic, University Hospital RWTH Aachen, Pauwelsstr. 30, 52074, Aachen, Germany
| | - I Knaup
- Department of Orthodontics, Dental Clinic, University Hospital RWTH Aachen, Pauwelsstr. 30, 52074, Aachen, Germany
| | - M Wolf
- Department of Orthodontics, Dental Clinic, University Hospital RWTH Aachen, Pauwelsstr. 30, 52074, Aachen, Germany
| |
Collapse
|
12
|
Bardideh E, Ghorbani M, Shafaee H, Saeedi P, Younessian F. A comparison of CAD/CAM-based fixed retainers versus conventional fixed retainers in orthodontic patients: a systematic review and network meta-analysis. Eur J Orthod 2023; 45:545-557. [PMID: 37471113 DOI: 10.1093/ejo/cjad033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/21/2023]
Abstract
OBJECTIVE Comparing computer-aided design and computer-aided manufacturing (CAD/CAM) fixed retainers and conventional fixed retainers for their effectiveness in orthodontic patients using systematic review and meta-analysis of literature. SEARCH METHODS A comprehensive search was conducted in MEDLINE, Web of Science, EMBASE, Scopus, Cochrane's CENTRAL, Google Scholar, Ovid, and LILACS up to May 2023, with no language or date restrictions. SELECTION CRITERIA Only randomized clinical trials (RCTs) that complied with PICO questions were included, and the Cochrane Risk of Bias 2.0 (RoB 2) tool was used to assess the risk of bias in the included studies. DATA COLLECTION AND ANALYSIS Using custom-piloted forms, relevant data were retrieved from the included studies. Then a random-effects inverse variance meta-analysis was used to pool the results. Primary outcomes were stability of treatment results measured through dental cast measurements and periodontal status, while secondary outcomes were failure rates and patient-reported outcomes. RESULTS Seven RCTs with 601 participants were included in the review. In the short term (≤6 months), the meta-analysis showed no significant differences in inter-canine distance or arch length between CAD/CAM and conventional fixed retainers in mandibular retainers. However, for Little's irregularity index, single-stranded stainless-steel retainers were notably worse than Ni-Ti CAD/CAM retainers at 3 and 6 months, while multi-stranded stainless-steel retainers only diverged from CAD/CAM at the 6-month milestone, despite the overall clinical inconsequence of these changes. CAD/CAM retainers were associated with a lower plaque index than traditional retainers but no significant difference in gingival index. Failure rates did not differ significantly between CAD/CAM and other types of retainers in mandibular retainers. Nonetheless, one study had a high amount of CAD/CAM retainer failures leading to the study being stopped. CONCLUSIONS In the short term, CAD/CAM fixed retainers show promise as an alternative to traditional retainers. They may enhance periodontal health, as indicated by lower plaque index scores than conventional retainers. However, extensive research is needed to determine the long-term durability and effectiveness of CAD/CAM retainers in orthodontic treatment, particularly regarding their failure rate. Until comprehensive evidence is available, the use of CAD/CAM retainers should be tailored for each case. REGISTRATION The protocol for this systematic review was registered at PROSPERO with the ID CRD42023412741.
Collapse
Affiliation(s)
- Erfan Bardideh
- Dental Research Center, Orthodontics Department, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Mahsa Ghorbani
- Undergraduate Student of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Hooman Shafaee
- Dental Research Center, Orthodontics Department, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Pooya Saeedi
- Undergraduate Student of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Farnaz Younessian
- Orthodontics and Pediatric Dentistry Department, School of Dentistry, University of Maryland, Baltimore, MD, United States
| |
Collapse
|
13
|
Alabbadi AA, Abdalla EM, Hanafy SA, Yousry TN. A comparative study of CAD/CAM fabricated polyether ether ketone and fiber-glass reinforcement composites versus metal lingual retainers under vertical load (an in vitro study). BMC Oral Health 2023; 23:583. [PMID: 37605187 PMCID: PMC10441729 DOI: 10.1186/s12903-023-03268-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Accepted: 07/29/2023] [Indexed: 08/23/2023] Open
Abstract
BACKGROUND Retainer is a necessary procedure when orthodontic treatment complete to avoid relapse due to periodontal fiber elasticity and to allow for alveolar bone regeneration. Compare the influence of vertical force on the failure of three fixed retainers: CAD/CAM polyether ether ketone (PEEK), CAD/CAM fiber glass reinforced composites (FRCs), and lingual retainer wire "Bond-A-Braid™". MATERIALS AND METHODS One hundred and eight maxillary first premolars teeth were randomly allocated to three groups: Group A (CAD/CAM PEEK), Group B (CAD/CAM FRC), and Group C (lingual retainer wire " Bond-A-Braid™"). These retainers were bonded using Assure Plus Bonding Resin and GO TO Paste. For each specimen, a loading cycling and thermocycling machine was used. The failure debonding forces were measured on the interproximal segments using a universal testing machine with a cross-head speed of 1 mm/min. The adhesive remnant index (ARI) was calculated after identifying types of failure with a stereomicroscope at (X 20) magnification. RESULTS Group B and group C showed the highest failure bonding forces, with a mean of 209.67 ± 16.15 and 86.81 ± 4.59 N, respectively. However, Group A had a statistically significant lower bond failure force, with a mean value of 45.73 ± 4.48 N. At baseline, there was a statistically significant difference in connector retainer displacement between the three studied groups (p < .001). The ARI score was not statistically significant (p < .001) between the three study groups; for groups A and B, the ARI was predominantly score 3, and group C showed a mixed score of 2 and 3. The failure mode of retainers was investigated using an optical stereomicroscope. In group B, there was a cohesive breakdown in the retainer, and groups A and C exhibited failures primarily in the adhesive at the retainer interface. CONCLUSION All groups differed significantly, with group A having the lowest debonding force and group B having the highest. Furthermore, there was not a substantial variation in ARI, but there was a significant difference in connector retainer displacement and the types of failure amongst the three groups.
Collapse
Affiliation(s)
- Abdullah A. Alabbadi
- Department of Orthodontics, Faculty of Dentistry, Alexandria University, Champolion street, P. O. Box: 21521, Azarita, Alexandria Egypt
| | - Essam M. Abdalla
- Department of Orthodontics, Faculty of Dentistry, Alexandria University, Champolion street, P. O. Box: 21521, Azarita, Alexandria Egypt
| | - Seham A. Hanafy
- Department of Dental Biomaterials, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| | - Tarek N. Yousry
- Department of Orthodontics, Faculty of Dentistry, Alexandria University, Champolion street, P. O. Box: 21521, Azarita, Alexandria Egypt
| |
Collapse
|
14
|
Roser CJ, Bauer C, Hodecker L, Zenthöfer A, Lux CJ, Rues S. Comparison of six different CAD/CAM retainers vs. the stainless steel twistflex retainer: an in vitro investigation of survival rate and stability. J Orofac Orthop 2023:10.1007/s00056-023-00486-y. [PMID: 37378840 DOI: 10.1007/s00056-023-00486-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Accepted: 05/23/2023] [Indexed: 06/29/2023]
Abstract
PURPOSE To compare failure rates and maximum load capacity (Fmax) of six different computer-aided design/computer-aided manufacturing (CAD/CAM) retainers with those of the hand-bent five-stranded stainless steel twistflex retainer. MATERIALS AND METHODS Six groups (n = 8 per group) of commercially available CAD/CAM retainers (cobalt-chromium [CoCr], titanium grade 5 [Ti5], nickel-titanium [NiTi], zirconia [ZrO2], polyetheretherketone [PEEK], and gold) and twistflex retainers were tested for long-term sufficiency and for Fmax using a self-developed in vitro model. All retainer models underwent a simulated ageing process of about 15 years (1,200,000 chewing cycles with a force magnitude of 65 N at 45° followed by storage in water at 37 °C for 30 days). If retainers did not debond or break during ageing, their Fmax was determined in a universal testing machine. Data were statistically analysed using Kruskal-Wallis and Mann-Whitney U‑tests. RESULTS Twistflex retainers did not fail (0/8) during ageing and had the highest Fmax (445 N ± 51 N). Ti5 retainers were the only CAD/CAM retainers that also did not fail (0/8) and had similar Fmax values (374 N ± 62 N). All other CAD/CAM retainers had higher failure rates during ageing and significantly lower Fmax values (p < 0.01; ZrO2: 1/8, 168 N ± 52 N; gold: 3/8, 130 N ± 52 N; NiTi: 5/8, 162 N ± 132 N; CoCr: 6/8, 122 N ± 100 N; PEEK: 8/8, 65 ± 0 N). Failure was due to breakage in the NiTi retainers and debonding in all other retainers. CONCLUSION Twistflex retainers remain the gold standard regarding biomechanical properties and long-term sufficiency. Of the CAD/CAM retainers tested, Ti5 retainers seem to be the most suitable alternative. In contrast, all other CAD/CAM retainers investigated in this study showed high failure rates and had significantly lower Fmax values.
Collapse
Affiliation(s)
- Christoph J Roser
- Department of Orthodontics and Dentofacial Orthopedics, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
| | - Carolien Bauer
- Department of Orthodontics and Dentofacial Orthopedics, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Lutz Hodecker
- Department of Orthodontics and Dentofacial Orthopedics, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Andreas Zenthöfer
- Department of Prosthodontics, Heidelberg University Hospital, University of Heidelberg, Im Neuenheimer Feld 400, Heidelberg, Germany
| | - Christopher J Lux
- Department of Orthodontics and Dentofacial Orthopedics, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Stefan Rues
- Department of Prosthodontics, Heidelberg University Hospital, University of Heidelberg, Im Neuenheimer Feld 400, Heidelberg, Germany
| |
Collapse
|
15
|
Jowett AC, Littlewood SJ, Hodge TM, Dhaliwal HK, Wu J. CAD/CAM nitinol bonded retainer versus a chairside rectangular-chain bonded retainer: A multicentre randomised controlled trial. J Orthod 2023; 50:55-68. [PMID: 36062600 PMCID: PMC10031634 DOI: 10.1177/14653125221118935] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Revised: 07/15/2022] [Accepted: 07/25/2022] [Indexed: 11/16/2022]
Abstract
BACKGROUND Bonded retainers are widely used to maintain the positions of anterior teeth after orthodontic treatment. Various types of bonded retainer exist however, there is a lack of evidence to indicate which type is superior. AIM To compare upper and lower CAD/CAM nitinol bonded retainers (Memotain®) with upper and lower chairside rectangular-chain bonded retainers (Ortho-FlexTech™), in terms of stability, retainer failures and patient satisfaction. TRIAL DESIGN Multi-centre, two-arm, parallel-group, randomised controlled clinical trial with 1:1 allocation. SETTING Three trial centres: University Teaching Hospital; District General Hospital; and Specialist Orthodontic Practice. All treatment was provided free as part of a state-funded healthcare system. MATERIALS AND METHODS A total of 68 patients were randomly allocated to receive either upper and lower Memotain® bonded retainers or upper and lower Ortho-FlexTech™ bonded retainers. Ten trained operators placed and reviewed the bonded retainers. Measurements were carried out on study models taken at debond and after six months. Patient satisfaction questionnaires were completed at six months following debond. RESULTS The trial was terminated due to the high number of failures (50%) of the upper Memotain® retainers within six months. Memotain® retainers were three times more likely to fail (unadjusted hazard ratio = 2.82, 95% confidence interval = 1.00-7.99) than Ortho-FlexTech™ retainers at six months in the upper arch. Patients were satisfied with both types of retainer. LIMITATIONS Early termination of the trial means that the a priori sample size was not reached, so outcomes should be interpreted with caution. CONCLUSION The trial was terminated early due to the high failure rate of upper Memotain® bonded retainers. They had a higher risk of failure in the maxillary arch when compared to upper Ortho-FlexTech™ bonded retainers after six months.
Collapse
Affiliation(s)
- Adam C Jowett
- Orthodontic Department, Leeds Dental
Institute, Leeds, UK
| | | | - Trevor M Hodge
- Orthodontic Department, Leeds Dental
Institute, Leeds, UK
| | | | - Jianhua Wu
- University of Leeds, School of
Dentistry, Leeds, UK
| |
Collapse
|
16
|
Gera A, Pullisaar H, Cattaneo PM, Gera S, Vandevska-Radunovic V, Cornelis MA. Stability, survival, and patient satisfaction with CAD/CAM versus conventional multistranded fixed retainers in orthodontic patients: a 6-month follow-up of a two-centre randomized controlled clinical trial. Eur J Orthod 2023; 45:58-67. [PMID: 35964235 PMCID: PMC9912708 DOI: 10.1093/ejo/cjac042] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
OBJECTIVES The primary aim of this two-arm parallel two-centre randomized controlled trial was to compare computer-aided design and computer-aided manufacturing (CAD/CAM) versus conventional multistranded fixed retainers (FRs) in terms of stability over 6 months. Secondary outcomes were failure rates and patient satisfaction. METHODS Patients were randomized to CAD/CAM or conventional FRs in both arches, in 1:1 ratio and blocks of four. Allocation concealment was secured by using sequentially numbered envelopes. Patients were blinded. Retainers were bonded at the end of orthodontic treatment (T0), and patients were recalled after 1 (T1), 3 (T3), and 6 (T6) months. First-time retainer failures were recorded and digital impressions were taken. Arch widths and lengths, as well as Little's Irregularity Index (LII), were measured. Additionally, patients answered satisfaction questionnaires. Linear mixed models were applied for measurements and patient satisfaction. Survival analyses were estimated with Kaplan-Meier curves, along with Cox-regression modelling. RESULTS One hundred and eighty-one patients were randomized (98 in Centre 1, and 83 in Centre 2): Ninety in the CAD/CAM group and 91 in the conventional group. Three subjects dropped out at baseline, as they did not attend any of the follow-up appointments.168 patients attended the T6 visit. There were no significant differences in arch dimensions between T0 and T6, whilst the LII was different only in the CAD/CAM group (mean difference: 0.2 mm; 95% confidence interval: 0.1 to 0.4; P < 0.001). Within 6 months, 39 upper retainers (19 out of 88 CAD/CAM and 20 out of 90 conventional retainers) and 52 lower retainers failed (26 out of 88 CAD/CAM and 26 out of 90 conventional retainers), with no significant difference between the survival of both types of retainers (hazard ratios conventional to CAD/CAM: upper arch: 0.99 [P =0.99], lower arch: 0.93 [P = 0.80]). There were no significant changes in patient satisfaction between the groups. No harms were observed. CONCLUSIONS There were no clinically significant differences in LII, arch widths and lengths between CAD/CAM and conventional retainers after 6 months. There was no difference in failures and in patient satisfaction between both types of FRs. REGISTRATION ClinicalTrials.gov NCT04389879.
Collapse
Affiliation(s)
- Arwa Gera
- Section of Orthodontics, Department of Dentistry and Oral Health, Aarhus University, Aarhus, Denmark
| | - Helen Pullisaar
- Department of Orthodontics, Institute of Clinical Dentistry, Faculty of Dentistry, University of Oslo, Norway
| | - Paolo M Cattaneo
- Melbourne Dental School, Faculty of Medicine, Dentistry and Health Sciences, Melbourne, Australia
| | | | - Vaska Vandevska-Radunovic
- Department of Orthodontics, Institute of Clinical Dentistry, Faculty of Dentistry, University of Oslo, Norway
| | - Marie A Cornelis
- Melbourne Dental School, Faculty of Medicine, Dentistry and Health Sciences, Melbourne, Australia
| |
Collapse
|
17
|
Kang SH, Kwon JS, Chung CJ, Cha JY, Lee KJ. Accuracy and stability of computer-aided customized lingual fixed retainer: a pilot study. Prog Orthod 2022; 23:39. [PMID: 36404385 PMCID: PMC9676156 DOI: 10.1186/s40510-022-00436-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Accepted: 08/18/2022] [Indexed: 11/22/2022] Open
Abstract
BACKGROUND With advances in digital technology, new types of lingual fixed retainers are being developed. However, there are few studies that quantitatively evaluate the accuracy and stability of lingual fixed retainers. The aim of this study was to assess the accuracy and stability of two types of computer-aided customized lingual fixed retainers and a conventional lingual fixed retainer. METHODS A total of 10 maxillary and 10 mandibular duplicated dental models were selected, and then, three types of retainers were fabricated on the canine-to-canine area for each model. To evaluate accuracy, wire clearance at interproximal area (WCI) was measured using superimposition analysis. Initial flatness deformation was also measured for vertical distortion of retainers. Lateral width, anteroposterior length, and flatness deformation were measured at three-time points for stability assessment. Thermocycling was used to induce 6 months of time flow. RESULTS The custom-bent group showed significantly higher WCI than the custom-cut and manual groups in the maxillary arch (P = 0.002). The custom-cut group showed significantly less flatness deformation, which was followed by the custom-bent and manual groups in both the maxillary and mandibular arch (P < 0.001). There was no significant difference in stability between the three retainer groups during 5100 cycles of thermocycling (corresponding to 6-month period). CONCLUSIONS Since there was no difference in stability between the three groups, it is recommended to use custom-cut type retainers in light of accuracy. However, accuracy and stability are not the only factors to consider when selecting type of retainers. Because each retainer has advantages and disadvantages, the type of retainers should be decided in consideration of the clinical environment.
Collapse
Affiliation(s)
- Seung-Hyun Kang
- grid.15444.300000 0004 0470 5454Department of Orthodontics, The Institute of Craniofacial Deformity, College of Dentistry, Yonsei University, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, Korea
| | - Jae-Sung Kwon
- grid.15444.300000 0004 0470 5454Department and Research Institute of Dental Biomaterials and Bioengineering, Yonsei University College of Dentistry, Seoul, 03722 Korea
| | - Chooryung Judi Chung
- grid.459553.b0000 0004 0647 8021Department of Orthodontics, Gangnam Severance Hospital, 211, Eonju-ro, Gangnam-gu, Seoul, Korea
| | - Jung-Yul Cha
- grid.15444.300000 0004 0470 5454Department of Orthodontics, The Institute of Craniofacial Deformity, College of Dentistry, Yonsei University, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, Korea
| | - Kee-Joon Lee
- grid.15444.300000 0004 0470 5454Department of Orthodontics, The Institute of Craniofacial Deformity, College of Dentistry, Yonsei University, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, Korea
| |
Collapse
|
18
|
Sfondrini MF, Pascadopoli M, Beccari S, Beccari G, Rizzi C, Gandini P, Scribante A. Orthodontic Fixed Retainer and Unwanted Movements of Lower Anterior Teeth: A Case Report. Case Rep Dent 2022; 2022:3100360. [PMID: 36090691 PMCID: PMC9463015 DOI: 10.1155/2022/3100360] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Accepted: 08/17/2022] [Indexed: 12/03/2022] Open
Abstract
The use of fixed retainers at the end of an orthodontic treatment has become a standard practice. Nonetheless, orthodontic relapse can still occur, requiring retreatment in the most severe cases. This case report describes a patient with a mandibular canine to canine fixed retainer presenting uncontrolled torque on all lower anterior teeth, probably due to tongue thrust and/or activation of the wire. Multibracket orthodontic treatment was performed, and an orthodontic lingual sectional was used to control (reposition) the root movement of the lower right cuspid. This case highlights the need for clinicians and patients to be aware of the potential problems associated with bonded retainers. In addition, patients with an orthodontic fixed retainer need regular short-term observation by an orthodontist in order to detect any adverse movements and long-term control by a general dentist.
Collapse
Affiliation(s)
- Maria Francesca Sfondrini
- Unit of Orthodontics and Pediatric Dentistry, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, Pavia 27100, Italy
| | - Maurizio Pascadopoli
- Unit of Orthodontics and Pediatric Dentistry, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, Pavia 27100, Italy
| | - Sergio Beccari
- Unit of Orthodontics and Pediatric Dentistry, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, Pavia 27100, Italy
| | - Giovanna Beccari
- Unit of Orthodontics and Pediatric Dentistry, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, Pavia 27100, Italy
| | - Cinzia Rizzi
- Unit of Orthodontics and Pediatric Dentistry, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, Pavia 27100, Italy
| | - Paola Gandini
- Unit of Orthodontics and Pediatric Dentistry, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, Pavia 27100, Italy
| | - Andrea Scribante
- Unit of Orthodontics and Pediatric Dentistry, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, Pavia 27100, Italy
| |
Collapse
|
19
|
Efficacy of CAD/CAM Technology in Interventions Implemented in Orthodontics: A Scoping Review of Clinical Trials. BIOMED RESEARCH INTERNATIONAL 2022; 2022:5310555. [PMID: 35692590 PMCID: PMC9184227 DOI: 10.1155/2022/5310555] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/03/2022] [Revised: 04/22/2022] [Accepted: 05/18/2022] [Indexed: 11/18/2022]
Abstract
Objectives. To evaluate the efficacy of computer-aided design/computer-aided manufacturing (CAD/CAM) technology in interventions implemented in orthodontics. Methods. A scoping review of scientific evidence was accomplished, involving different databases. MesH terms and keywords were provided to examine clinical trials (CTs) in all languages. Exclusively CTs that fulfilled the eligibility criteria were admitted. Results. Eight CTs were chosen. These experiments evaluated 542 patients. Four CTs compared the computer-aided indirect bonding method versus the traditional direct bonding of orthodontic brackets. Three CTs compared CAD/CAM retainers with other types of retainers, and one CT compared the CAD/CAM group with multistranded stainless steel wires versus stainless steel wires. Regarding the efficacy of the interventions with CAD/CAM technology used in orthodontics, variable results were found. The indirect bonded customized CAD/CAM brackets presented just a slight effect on the treatment efficacy and therapy results. Two CTs showed that an indirect bonding self-ligating standard system had a similar quality of therapy in comparison with the CAD/CAM customized bracket system. Concerning the clinical failure rate, no differences were presented between the CAD/CAM retainer and other retainers. A CAD/CAM system had more loose brackets than a noncustomized system and was observed also a greater amount of immediate debonding with CAD/CAM indirect bonding than with direct bonding. CAD/CAM fixed retainers revealed inferior relapse and fewer failures than lab-based and conventional chairside retainers. No changes between treatment groups were observed regarding the total therapy time, amount of appointments, and quantity of archwire bends. Conclusions. In general terms, no greater efficacy of CAD/CAM technology was observed over traditional therapies used in orthodontics. However, it was found that gingival inflammation and the accumulation of bacterial plaque and dental calculus were lower when CAD/CAM retainers were used. When comparing interventions that include CAD/CAM systems with conventional therapies, no significant reduction in care times was found.
Collapse
|
20
|
Cornelis MA, Egli F, Bovali E, Kiliaridis S, Cattaneo PM. Indirect vs direct bonding of mandibular fixed retainers in orthodontic patients: Comparison of retainer failures and posttreatment stability. A 5-year follow-up of a single-center randomized controlled trial. Am J Orthod Dentofacial Orthop 2022; 162:152-161.e1. [PMID: 35551840 DOI: 10.1016/j.ajodo.2022.03.014] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2021] [Revised: 03/03/2022] [Accepted: 03/03/2022] [Indexed: 11/01/2022]
Abstract
INTRODUCTION This 2-arm parallel trial aimed to assess the number of failures of mandibular fixed retainers bonded with direct and indirect bonding methods at a 5-year follow-up and investigate the stability of intercanine and interpremolar distances. METHODS Consecutive patients from the clinic of the University of Geneva (Switzerland) were randomly allocated to either direct or indirect bonding of a mandibular fixed retainer at the end of orthodontic treatment. Inclusion criteria included the presence of all mandibular incisors and canines; and the absence of active caries, restorations, fractures, or periodontal disease of these teeth. The patients were randomized in blocks of 4 using an online randomization service, with allocation concealment secured by contacting the sequence generator for assignment. Two and 5 years (T5) after bonding the retainers, the patients were recalled, and impressions were taken. The primary outcome was the 5-year survival of the mandibular fixed retainer bonded with both bonding methods. The secondary outcomes were the intercanine and interpremolar distances and the assessment of unexpected posttreatment changes (ie, changes in torque and/or rotations of the mandibular incisors and canines). Blinding was applicable for outcome assessment only. Kaplan-Meier curves were generated, and a Cox proportional hazard regression model was fitted for bonding type, age, and treatment. Linear mixed models were fitted to intercanine and interpremolar distances: bonding type, time, age, and treatment were modeled as outcomes. RESULTS Sixty-four patients were randomized in a 1:1 ratio. At T5, 6 patients without previous failure were lost to follow-up from each group. At T5, the fixed retainer was debonded in 14 patients (54%) for each group. The hazard ratio of indirect bonding to direct bonding was 1.09 (95% confidence interval, 0.26-4.60; P = 0.91); there was no statistically significant difference in survival between the groups. Regarding intercanine and interpremolar distances, none of the tested prognostic factors reached statistical significance. Unexpected posttreatment changes were observed in 6 failure-free patients, all bonded with the direct bonding method. Only 1 patient required debonding of the fixed retainer. No other serious harms were observed. CONCLUSIONS The 5-year survival rate for both direct and indirect bonding methods was 46%, without a statistically significant difference between bonding methods. Bonded retainers were effective in maintaining intercanine and interpremolar distances. Unexpected posttreatment changes were only observed with retainers bonded with the direct bonding method. REGISTRATION The trial was not registered. PROTOCOL The protocol was not published before trial commencement. FUNDING No funding or conflict of interest to be declared.
Collapse
Affiliation(s)
- Marie A Cornelis
- Melbourne Dental School, Faculty of Medicine, Dentistry, and Health Sciences, University of Melbourne, Melbourne, Australia.
| | - Fabienne Egli
- Division of Orthodontics, School of Dentistry, University of Geneva, Geneva, Switzerland
| | | | - Stavros Kiliaridis
- Division of Orthodontics, School of Dentistry, University of Geneva, Geneva, Switzerland
| | - Paolo M Cattaneo
- Melbourne Dental School, Faculty of Medicine, Dentistry, and Health Sciences, University of Melbourne, Melbourne, Australia
| |
Collapse
|
21
|
Digital Design of Different Transpalatal Arches Made of Polyether Ether Ketone (PEEK) and Determination of the Force Systems. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12031590] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Abstract
The aim of this study was to investigate whether the polymer polyether ether ketone (PEEK), which is approved for (dental) medical appliances, is suitable for the production of orthodontic treatment appliances. Different geometries of transpalatal arches (TPAs) were designed by Computer Aided Design (CAD). Out of a number of different designs and dimensions, four devices were selected and manufactured by milling out of PEEK. A finite element analysis (FEA) and a mechanical in vitro testing were performed to analyze the force systems acting on the first upper molars. Up to an activation (transversal compression) of 4 mm per side (total 8 mm), the PEEK TPAs generated forces between 1.3 and 3.1 Newton (N) in the FEA and between 0.7 and 3.2 N in the mechanical testing. The moments in the oro-vestibular direction were measured between 2.1 and 6.6 Nmm in the FEA and between 1.1 and 6.0 Nmm in the mechanical testing, depending on the individual TPA geometry. With the help of the FEA, it was possible to calculate the von Mises stresses and the deformation patterns of the different TPAs. In some areas, local von Mises stresses exceeded 154–165 MPa, which could lead to a permanent deformation of the respective appliances. In the in vitro testing, however, none of the TPAs showed any visible deformation or fractures. With the help of the FEA and the mechanical testing, it could be shown that PEEK might be suitable as a material for the production of orthodontic TPAs.
Collapse
|
22
|
Zeng Y, Xiao L, Yuan X. Displacement and stress distribution of mandibular incisors after orthodontic treatment in the presence of alveolar bone loss under occlusal loads: A finite element analysis. Am J Orthod Dentofacial Orthop 2022; 161:e456-e465. [DOI: 10.1016/j.ajodo.2022.01.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2021] [Revised: 01/01/2022] [Accepted: 01/01/2022] [Indexed: 11/01/2022]
|
23
|
Shim H, Foley P, Bankhead B, Kim KB. Comparative assessment of relapse and failure between CAD/CAM stainless steel and standard stainless steel fixed retainers in orthodontic retention patients. Angle Orthod 2022; 92:87-94. [PMID: 34464438 DOI: 10.2319/121720-1015.1] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Accepted: 07/01/2021] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVES To compare relapse and failure rates of computer-aided design/computer-aided manufacturing (CAD/CAM) and standard fixed retainers. MATERIALS AND METHODS This single-center, single-blinded, prospective randomized clinical trial included 46 patients who completed active orthodontic treatment and complied with retention visits. The patients were randomly assigned to three groups: CAD/CAM group with multistranded stainless steel wires (CAD/CAM, n = 16), Lab group with the same multistranded wires (lab, n = 16), and control group with stainless steel Ortho-FlexTech wires (traditional, n = 14). Intraoral scans were obtained at placement of fixed retainers (T1), 3-month visit (T2), and 6-month visit (T3) and measured for intercanine width and Little's Irregularity Index. Failures were recorded. RESULTS The CAD/CAM group experienced less intercanine width decrease than the traditional group at 3 months (mean difference, 0.83 ± 0.16 mm; 95% confidence interval [CI], 0.44-1.22; P < .001) and 6 months (mean difference, 1.23 ± 0.40 mm; 95% CI, 0.19-2.27; P < .05). The CAD/CAM group experienced less increase in Little's Irregularity Index compared with the lab group within 3 months (mean difference, 0.81 ± 0.27 mm; 95% CI, 0.12-1.49; P < .05). Failures from greatest to least were experienced by the lab group (43.8%), the CAD/CAM group (25%), and the traditional group (14.3%). CONCLUSIONS Within 6 months of bonding fixed retainers, CAD/CAM fixed retainers showed less relapse than lab-based and traditional chairside retainers and less failures than lab-based retainers.
Collapse
|
24
|
Memon AR, Li J, Egger J, Chen X. A review on patient-specific facial and cranial implant design using Artificial Intelligence (AI) techniques. Expert Rev Med Devices 2021; 18:985-994. [PMID: 34404280 DOI: 10.1080/17434440.2021.1969914] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
INTRODUCTION Researchers and engineers have found their importance in healthcare industry including recent updates in patient-specific implant (PSI) design. CAD/CAM technology plays an important role in the design and development of Artificial Intelligence (AI) based implants.The across the globe have their interest focused on the design and manufacturing of AI-based implants in everyday professional use can decrease the cost, improve patient's health and increase efficiency, and thus many implant designers and manufacturers practice. AREAS COVERED The focus of this study has been to manufacture smart devices that can make contact with the world as normal people do, understand their language, and learn to improve from real-life examples. Machine learning can be guided using a heavy amount of data sets and algorithms that can improve its ability to learn to perform the task. In this review, artificial intelligence (AI), deep learning, and machine-learning techniques are studied in the design of biomedical implants. EXPERT OPINION The main purpose of this article was to highlight important AI techniques to design PSIs. These are the automatic techniques to help designers to design patient-specific implants using AI algorithms such as deep learning, machine learning, and some other automatic methods.
Collapse
Affiliation(s)
- Afaque Rafique Memon
- State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Institute of Bio-medical Manufacturing and Life Quality Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Jianning Li
- Faculty of Computer Science and Biomedical Engineering, Institute of Computer Graphics and Vision, Graz University of Technology, Graz, Austria.,The Laboratory of Computer Algorithm for Medicine, Medical University of Graz, Graz, Austria.,Department of Neurosurgery, Medical University of Graz, Graz, Austria
| | - Jan Egger
- Faculty of Computer Science and Biomedical Engineering, Institute of Computer Graphics and Vision, Graz University of Technology, Graz, Austria.,The Laboratory of Computer Algorithm for Medicine, Medical University of Graz, Graz, Austria.,Department of Neurosurgery, Medical University of Graz, Graz, Austria.,Department of Oral and Maxillofacial Surgery, Medical University of Graz, Graz, Austria
| | - Xiaojun Chen
- State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Institute of Bio-medical Manufacturing and Life Quality Engineering, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
25
|
Korkmaz YN, Arslan S. Transfer accuracy of four different lingual retainer transfer methods using digital orthodontic models: An in vivo comparative study. Angle Orthod 2021; 91:778-785. [PMID: 34287650 DOI: 10.2319/020921-118.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Accepted: 05/01/2021] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVES To compare the transfer accuracy of four different lingual retainer (LR) transfer methods using three-dimensional digital models. MATERIALS AND METHODS Four groups of 17 patients each were created: finger transfer (FT), silicone key transfer (SKT), acrylic resin transfer (ART), and indirect bonding (IDB). At the end of orthodontic treatment, the mandibular dental casts of patients were scanned with the LR wire. Then, intraoral scanning of the mandibular arches was performed after bonding the retainer wires. Linear and angular measurements were made using software on superimposed digital models. RESULTS Horizontal and vertical errors among the teeth were not significantly different among the FT, SKT, and ART groups. However, in the IDB group, linear transfer errors showed significant differences among the different teeth. The tip and rotation errors in the FT group were not significantly different among the teeth. The angular errors were lower in canines than in the incisors. In all measured parameters, the SKT group showed the lowest errors, whereas the FT group had the highest transfer errors in all parameters except vertical. CONCLUSIONS Among the transfer methods tested, SKT was determined to have the highest clinical accuracy.
Collapse
|
26
|
Adanur-Atmaca R, Çokakoğlu S, Öztürk F. Effects of different lingual retainers on periodontal health and stability. Angle Orthod 2021; 91:468-476. [PMID: 33587126 PMCID: PMC8259753 DOI: 10.2319/110220-904.1] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2020] [Accepted: 01/01/2021] [Indexed: 12/30/2022] Open
Abstract
OBJECTIVES To evaluate the effects of different lingual retainers on periodontal health and stability of mandibular anterior teeth at the 1-year follow-up. MATERIALS AND METHODS One hundred thirty-two patients were randomly allocated to four groups using different lingual retainers: group 1, 0.016 × 0.022-in dead-soft wire; group 2, 0.0215-in 5-strand stainless steel wire; group 3, 0.014 × 0.014-in computer-aided design/computer-aided manufacturing nitinol retainer (Memotain); group 4, connected bonding pads. Plaque, gingival, and calculus indexes were used to evaluate periodontal health, and Little's irregularity index, intercanine width, and arch length measurements were performed to evaluate stability. All measurements were performed at each time point (debonding and 3, 6, 9, and 12 months). RESULTS The mean value of the gingival index obtained in group 3 was lower than the mean value for all other groups. The mean value of the calculus index was the lowest in group 3, and there was a significant difference between group 3 and groups 1 and 2. No differences were found among the groups in terms of plaque index, intercanine width, and arch length. The least irregularity was obtained in groups 2 and 3. There were no significant differences between these groups and groups 1 and 4. CONCLUSIONS Gingival inflammation and calculus accumulation were the lowest in group 3 (Memotain). The irregularity for Memotain and stainless steel retainers was less than or the other groups. However, no clinically significant worsening of periodontal health or relapse were seen in any groups after 1 year.
Collapse
|
27
|
Fudalej PS, Renkema AM. A brief history of orthodontic retention. Br Dent J 2021; 230:777-780. [PMID: 34117438 DOI: 10.1038/s41415-021-2955-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Accepted: 01/25/2021] [Indexed: 11/09/2022]
Abstract
The retention phase has become an accepted part of orthodontic therapy. Irrespective of the patient's age, underlying malocclusion or the type of mechanotherapy, an orthodontist will use some retention method in virtually every patient following completion of the active treatment. This article presents a short description of the history of orthodontic retention and highlights major developments in retention strategy.
Collapse
Affiliation(s)
- Piotr S Fudalej
- Department of Orthodontics, Jagiellonian University in Krakow, Krakow, Poland; Department of Orthodontics, Institute of Dentistry and Oral Sciences, Palacký University Olomouc, Olomouc, Czech Republic; Department of Orthodontics and Dentofacial Orthopedics, University of Bern, Bern, Switzerland.
| | - Anne-Marie Renkema
- Department of Orthodontics, University of Groningen, Groningen, The Netherlands
| |
Collapse
|
28
|
Fixed retention: pitfalls and complications. Br Dent J 2021; 230:703-708. [PMID: 34117424 DOI: 10.1038/s41415-021-2892-4] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Accepted: 09/08/2020] [Indexed: 11/08/2022]
Abstract
Long-term stability of orthodontic treatment results is problematic. Long-term or even lifelong retention with bonded retainers is being increasingly used among clinicians. Bonded retainers can provide an efficient and attractive method of retention, particularly because they require minimal compliance from patients. However, the use of bonded retainers is associated with relatively frequent complications, such as detachments of the adhesive layer or wire fractures, as well as unexpected complications with potentially severe consequences with associated periodontal and general health risks. It is imperative that the whole dental team are aware of these pitfalls and complications, and appreciate how to minimise and address these.
Collapse
|
29
|
Littlewood SJ, Dalci O, Dolce C, Holliday LS, Naraghi S. Orthodontic retention: what's on the horizon? Br Dent J 2021; 230:760-764. [PMID: 34117435 PMCID: PMC8193167 DOI: 10.1038/s41415-021-2937-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2020] [Accepted: 10/14/2020] [Indexed: 11/08/2022]
Abstract
Orthodontic retention remains one of the great challenges in orthodontics. In this article, we discuss what is on the horizon to help address this challenge, including biological approaches to reduce relapse, treating patients without using retainers, technological developments, personalised medicine and the impact of COVID-19 on approaches to orthodontic retention.
Collapse
Affiliation(s)
- Simon J Littlewood
- Consultant Orthodontist, Department of Orthodontics, St Luke's Hospital, Bradford, UK.
| | - Oyku Dalci
- Senior Lecturer, Discipline of Orthodontics and Paediatric Dentistry, School of Dentistry, Faculty of Medicine and Health, University of Sydney, Australia
| | - Calogero Dolce
- Professor and Chairman, Department of Orthodontics, University of Florida, College of Dentistry, Gainesville, Florida, USA
| | - L Shannon Holliday
- Associate Professor, Department of Orthodontics, University of Florida, College of Dentistry, Gainesville, Florida, USA
| | - Sasan Naraghi
- Consultant Orthodontist, Orthodontic Clinic, Public Dental Health, Växjö, Sweden
| |
Collapse
|
30
|
Aboulazm K, von See C, Othman A. Fixed lingual orthodontic retainer with bilateral missing lateral incisors produced in PEEK material using CAD/CAM technology. J Clin Exp Dent 2021; 13:e549-e551. [PMID: 34188759 PMCID: PMC8223158 DOI: 10.4317/jced.58035] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Accepted: 12/20/2020] [Indexed: 11/05/2022] Open
Abstract
Background The aim of this investigation is to evaluate the feasibility of digital workflow for lingual fixed retainer based on digital intraoral scan and appliance production from Polyetheretherketone (PEEK) material for clinical consideration. Material and Methods Fully virtual lingual retainer with bilateral missing lateral incisors was designed using inlab software (Dentsply Sirona, Pennsylvania, USA). The designed retainer was produced in PEEK material and clinically adhered to lingual surfaces of the lower front teeth. Results Lingual retainer was successfully fabricated by full digital workflow and produced from PEEK material for clinical usage. Conclusions Although full digital workflow can be clinically used for production of prefabricated lingual retainer, however further software adaptions are required for improvement of the orthodontic workflow. Key words:PEEK, CAD/CAM, digital orthodontics, lingual retainer.
Collapse
Affiliation(s)
- Khaled Aboulazm
- Assoc. Prof., MSc, PhD. Chairman of orthodontic department in Pharos Private University-Alexandria- Egypt
| | - Constantin von See
- Univ. Prof., MSc. Director of digital technologies in dentistry and CAD/CAM department-Danube Private University-Krems-Austria
| | - Ahmed Othman
- Ass. Prof. Dr, MSc. Orthodontic researcher in digital technologies in dentistry and CAD/CAM department-Danube Private University-Krems-Austria
| |
Collapse
|
31
|
Knaup I, Bartz JR, Schulze-Späte U, Craveiro RB, Kirschneck C, Wolf M. Side effects of twistflex retainers-3D evaluation of tooth movement after retainer debonding. J Orofac Orthop 2020; 82:121-130. [PMID: 33258981 DOI: 10.1007/s00056-020-00265-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2019] [Accepted: 08/16/2020] [Indexed: 10/22/2022]
Abstract
PURPOSE Evaluation of tooth movement after retainer debonding in retainer-associated misalignment cases. METHODS This pilot study is based on a retrospective data analysis. Adult patients (age 25.5 ± 4.9 years) wearing fixed twistflex retainers and having visible retainer-associated misalignment were included and examined for tooth movement after retainer debonding. Orthodontic study models were taken at retainer debonding (t0) and 14 (±1) weeks later (t1). They were digitally superimposed using 2D/3D dental imaging software and tooth movement was analyzed in all three dimensions. RESULTS A total of 23 teeth (12 upper teeth: 10 incisors, 2 canines; 11 lower teeth: 7 incisors, 4 canines) were analyzed. Mean overall tipping was 1.11 ± 0.82° in the mesial/distal direction (angulation, x‑axis), 2.02 ± 1.9° in the buccal/lingual direction (inclination, y‑axis) and 1.28 ± 0.99° around the tooth axis (z-axis). Mean overall bodily movement was 0.30 ± 0.31 mm in the mesial/distal direction (angulation, x‑axis), 0.10 ± 0.13 mm in the buccal/lingual direction (inclination, y‑axis), and mean in- or extrusion 0.22 ± 0.24 mm (z-axis). Mean tipping and bodily movement were more pronounced in the upper jaw. CONCLUSION The present data shows that tooth movement after debonding of twistflex retainers can be expected in misalignment cases.
Collapse
Affiliation(s)
- Isabel Knaup
- Department of Orthodontics, RWTH Aachen University Hospital, Aachen, Germany.
| | - Jenny Rosa Bartz
- Department of Orthodontics, RWTH Aachen University Hospital, Aachen, Germany
| | - Ulrike Schulze-Späte
- Section of Geriodontics, Department of Conservative Dentistry and Periodontology, Jena University Hospital, Jena, Germany
| | | | | | - Michael Wolf
- Department of Orthodontics, RWTH Aachen University Hospital, Aachen, Germany
| |
Collapse
|
32
|
Gelin E, Seidel L, Bruwier A, Albert A, Charavet C. Innovative customized CAD/CAM nickel-titanium lingual retainer versus standard stainless-steel lingual retainer: A randomized controlled trial. Korean J Orthod 2020; 50:373-382. [PMID: 33144526 PMCID: PMC7642231 DOI: 10.4041/kjod.2020.50.6.373] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Revised: 06/23/2020] [Accepted: 06/26/2020] [Indexed: 12/22/2022] Open
Abstract
Objective To compare computer-aided design and computer-aided manufacturing (CAD/CAM) customized nitinol retainers with standard stainlesssteel fixed retainers over a 12-month study period. Methods This randomized controlled trial (RCT) was conducted on 62 patients randomly allocated to a control group that received stainless-steel retainers or a test group that received customized CAD/CAM nickel-titanium retainers. Four time points were defined: retainer placement (T0) and 1-month (T1), 6-month (T2), and 12-month (T3) follow-up appointments. At each time point, Little's irregularity index (LII) (primary endpoint) and dental stability measurements such as intercanine width were recorded in addition to assessment of periodontal parameters. Radiological measurements such as the incisor mandibular plane angle (IMPA) were recorded at T0 and T3. Failure events (wire integrity or debonding) were assessed at each time point. Results From T0 to T3, LII and other dental measurements showed no significant differences between the two groups. The data for periodontal parameters remained stable over the study period, except for the gingival index, which was slightly, but significantly, higher in the test group at T3 (p = 0.039). The IMPA angle showed no intergroup difference. The two groups showed no significant difference in debonding events. Conclusions This RCT conducted over a 12-month period demonstrated no significant difference between customized CAD/CAM nickel-titanium lingual retainers and standard stainlesssteel lingual retainers in terms of dental anterior stability and retainer survival. Both retainers eventually appeared to be equally effective in maintaining periodontal health.
Collapse
Affiliation(s)
- Emilie Gelin
- Department of Orthodontics and Dentofacial Orthopedics, University Hospital of Liège, Liège, Belgium
| | - Laurence Seidel
- Department of Biostatistics and Medico-economic Information, University Hospital of Liège, University of Liège, Liège, Belgium
| | - Annick Bruwier
- Department of Orthodontics and Dentofacial Orthopedics, University Hospital of Liège, Liège, Belgium
| | - Adelin Albert
- Department of Biostatistics and Medico-economic Information, University Hospital of Liège, University of Liège, Liège, Belgium
| | - Carole Charavet
- Department of Orthodontics and Dentofacial Orthopedics, University Hospital of Liège, Liège, Belgium
| |
Collapse
|
33
|
Alrawas MB, Kashoura Y, Tosun Ö, Öz U. Comparing the effects of CAD/CAM nickel‐titanium lingual retainers on teeth stability and periodontal health with conventional fixed and removable retainers: A randomized clinical trial. Orthod Craniofac Res 2020; 24:241-250. [DOI: 10.1111/ocr.12425] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2020] [Revised: 07/27/2020] [Accepted: 08/18/2020] [Indexed: 01/05/2023]
Affiliation(s)
| | - Yaman Kashoura
- Department of Orthodontics School of Dentistry Near East University Nicosia Turkey
| | - Özgür Tosun
- Department of Biostatistics School of Medicine Near East University Nicosia Turkey
| | - Ulaş Öz
- Department of Orthodontics School of Dentistry Near East University Nicosia Turkey
| |
Collapse
|
34
|
Roser C, Hilgenfeld T, Sen S, Badrow T, Zingler S, Heiland S, Bendszus M, Lux CJ, Juerchott A. Evaluation of magnetic resonance imaging artifacts caused by fixed orthodontic CAD/CAM retainers-an in vitro study. Clin Oral Investig 2020; 25:1423-1431. [PMID: 32785849 PMCID: PMC7878219 DOI: 10.1007/s00784-020-03450-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Accepted: 07/07/2020] [Indexed: 12/27/2022]
Abstract
Objectives Magnetic resonance imaging (MRI) image quality can be severely impaired by artifacts caused by fixed orthodontic retainers. In clinical practice, there is a trend towards using computer-aided design/computer-aided manufacturing (CAD/CAM) retainers. This study aimed to quantify MRI artifacts produced by these novel CAD/CAM retainers. Material and methods Three CAD/CAM retainers and a stainless-steel retainer (“Twistflex”; clinical reference standard) were scanned in vitro at 3-T MRI using a high-resolution 3D sequence. The artifact diameters and three-dimensional artifact volumes (AV) were determined for all mandibular (AVmand) and maxillary (AVmax) retainers. Moreover, the corresponding ratio of artifact volume to retainer volume (AV/RVmand, AV/RVmax) was calculated. Results Twistflex caused large artifact volumes (AVmand: 13530 mm3; AVmax: 15642 mm3; AV/RVmand: 2602; AV/RVmax: 2235). By contrast, artifact volumes for CAD/CAM retainers were substantially smaller: whereas artifact volumes for cobalt–chromium retainers were moderate (381 mm3; 394 mm3; 39; 31), grade-5 titanium (110 mm3; 126 mm3; 12; 12) and nickel–titanium (54 mm3; 78 mm3; 12; 14) both produced very small artifact volumes. Conclusion All CAD/CAM retainers caused substantially smaller volumes of MRI artifacts compared to Twistflex. Grade-5 titanium and nickel–titanium CAD/CAM retainers showed the smallest artifact volumes. Clinical relevance CAD/CAM retainers made from titanium or nickel–titanium may not relevantly impair image quality in head/neck and dental MRI. Artifacts caused by cobalt–chromium CAD/CAM retainers may mask nearby dental/periodontal structures. In contrast, the large artifacts caused by Twistflex are likely to severely impair diagnosis of oral and adjacent pathologies.
Collapse
Affiliation(s)
- Christoph Roser
- Department of Orthodontics and Dentofacial Orthopedics, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
| | - Tim Hilgenfeld
- Department of Neuroradiology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Sinan Sen
- Department of Orthodontics and Dentofacial Orthopedics, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Tobias Badrow
- Department of Neuroradiology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Sebastian Zingler
- Department of Orthodontics and Dentofacial Orthopedics, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Sabine Heiland
- Department of Neuroradiology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Martin Bendszus
- Department of Neuroradiology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Christopher J Lux
- Department of Orthodontics and Dentofacial Orthopedics, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Alexander Juerchott
- Department of Neuroradiology, Heidelberg University Hospital, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| |
Collapse
|
35
|
Kartal Y, Kaya B, Polat-Özsoy Ö. Comparative evaluation of periodontal effects and survival rates of Memotain and five-stranded bonded retainers : A prospective short-term study. J Orofac Orthop 2020; 82:32-41. [PMID: 32780168 DOI: 10.1007/s00056-020-00243-5] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2019] [Accepted: 05/12/2020] [Indexed: 11/30/2022]
Abstract
PURPOSE To prospectively compare the short-term periodontal effects and survival rates of mandibular lingual canine-to-canine Memotain (CA-Digital, Mettmann, Germany) and five-stranded bonded retainers. METHODS In all, 52 patients requiring retention after orthodontic treatment were assigned to 2 study groups (n = 26 in each group). Retention was provided by Memotain retainers which were fabricated digitally using CAD-CAM (computer-aided design and computer-aided manufacturing) technology in the first group and by five-stranded retainers which were fabricated manually using a conventional bending method in the second group. The patients were examined at the following time points: 1 week, 1 month, 3 months and 6 months. Plaque index, gingival index, probing depth, marginal recession, bleeding on probing, failure rate per tooth, and survival rate of retainer wires were analyzed by Mann-Whitney U, Friedman, Wilcoxon signed-rank, and χ2 tests. RESULTS The differences between the groups were nonsignificant for plaque index, gingival index, probing depth, marginal recession, bleeding on probing, failure rate per tooth and survival rate of retainer wires. Significant differences were observed within the groups throughout the follow-up period for plaque index and probing depth. The survival rates of retainer wires were 77% for the Memotain retainers and 73% for the five-stranded retainers for the 6‑month follow-up period. CONCLUSIONS Periodontal outcomes and survival rates of Memotain and five-stranded mandibular lingual bonded retainers were similar. Furthermore, periodontal health was maintained and considerably high survival rates were achieved with both retainer types.
Collapse
Affiliation(s)
| | - Burçak Kaya
- Department of Orthodontics, Faculty of Dentistry, Başkent University, Ankara, Turkey. .,Dis Hekimligi Fakultesi, Ortodonti Anabilim Dali, Baskent Universitesi, 1. Cad No: 107, 06490, Bahcelievler-Ankara, Turkey.
| | | |
Collapse
|
36
|
Abstract
Indefinite retention is now considered essential to prevent relapse after orthodontic treatment. Compliance with removable retainer wear is suboptimal and appears to decline with time post-treatment. As a result, use of bonded retainers may become more commonplace in the future. In this narrative review, the characteristics of bonded retainers are outlined and a summary of the evidence from randomized clinical trials regarding their effectiveness is provided. Guidance is also offered regarding care and maintenance. CPD/Clinical Relevance: All general dental practitioners (GDPs) should be familiar with types of bonded retainers, evidence relating to their effectiveness and the GDP's role regarding their care and maintenance.
Collapse
Affiliation(s)
- Maurice J Meade
- Orthodontic Unit, The School of Dentistry, The University of Adelaide, South Australia, Australia
| | - Declan T Millett
- Professor of Orthodontics/Consultant, Orthodontic Unit, Cork University Dental School and Hospital, University College Cork, Ireland
| |
Collapse
|
37
|
Luqmani S, Jones A, Andiappan M, Cobourne MT. A comparison of conventional vs automated digital Peer Assessment Rating scoring using the Carestream 3600 scanner and CS Model+ software system: A randomized controlled trial. Am J Orthod Dentofacial Orthop 2020; 157:148-155.e1. [PMID: 32005465 DOI: 10.1016/j.ajodo.2019.10.011] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2019] [Revised: 10/01/2019] [Accepted: 10/01/2019] [Indexed: 11/30/2022]
Abstract
INTRODUCTION A prospective randomized study was undertaken to compare conventional study model-based manual Peer Assessment Rating (PAR) scoring with computer-based automated scoring using scanned study models or intraoral scanning. METHODS The sample consisted of 67 patients, mean age 15.03 (range 11-37) years. Sixty-seven patients underwent alginate impression-taking and intraoral scanning (CS 3600; Carestream Dental, Stuttgart, Germany) at a single appointment in a randomized order. For each patient, a weighted PAR score was calculated manually by a calibrated examiner using study models and a PAR ruler (conventional group), and automatically using Carestream Dental CS Model+ software and data from scanned study models (indirect digital group) or intraoral scans (direct digital group). All procedures were timed, and each patient completed a binary questionnaire relating to their experience. RESULTS There were no significant differences between methods for calculated mean weighted PAR score (P = 0.68). Mean (standard deviation) chairside time for impression-taking was 5.35 (± 1.16) minutes and for intraoral scanning, 7.76 (± 2.76) minutes (P <0.05). Mean (standard deviation) times taken to calculate weighted PAR scores were 2.86 (± 0.96), 5.58 (± 2.33), and 4.58 (± 2.18) minutes for conventional, indirect digital, and direct digital groups, respectively (P >0.05). A total of 61 patients (91%) preferred intraoral scanning to impression-taking. CONCLUSIONS Automated PAR scoring using cast study models or intraoral scanning is valid, though both methods take longer than conventional scoring. Patients prefer intraoral scanning to impression-taking. REGISTRATION ClinicalTrials.gov (NCT03405961). PROTOCOL The protocol was not published before study commencement.
Collapse
Affiliation(s)
- Sana Luqmani
- Centre for Craniofacial Development and Regeneration, Department of Orthodontics, Faculty of Dentistry, Oral and Craniofacial Sciences, King's College London, London, United Kingdom; Department of Orthodontics, Kingston Hospital NHS Foundation Trust, Kingston, United Kingdom
| | - Allan Jones
- Department of Orthodontics, Kingston Hospital NHS Foundation Trust, Kingston, United Kingdom
| | - Manoharan Andiappan
- Centre for Host-Microbiome Interactions, Faculty of Dentistry, Oral and Craniofacial Sciences, King's College London, London, United Kingdom
| | - Martyn T Cobourne
- Centre for Craniofacial Development and Regeneration, Department of Orthodontics, Faculty of Dentistry, Oral and Craniofacial Sciences, King's College London, London, United Kingdom.
| |
Collapse
|
38
|
Kravitz ND. The Maryland bridge retainer: A modification of a Maryland bridge. Am J Orthod Dentofacial Orthop 2020; 157:128-131. [PMID: 31901270 DOI: 10.1016/j.ajodo.2019.08.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2018] [Revised: 07/01/2019] [Accepted: 08/01/2019] [Indexed: 10/25/2022]
Abstract
Preservation of the maxillary lateral incisor space after orthodontic treatment in an adolescent patient traditionally requires the use of a retainer with a lateral pontic, commonly referred to as a "flipper," which is minimally effective in the long term. This article illustrates a technique for chairside fabrication of a Maryland bridge retainer for semi-permanent retention. A stainless steel braided palatal wire is bonded to the anterior teeth. A pontic is then built intraorally with flowable composite, using the palatal wire as scaffolding. The retainer is maintained until the patient is of age for a more permanent restoration.
Collapse
|
39
|
Graf S, Hansa I. Clinical guidelines to integrate temporary anchorage devices for bone-borne orthodontic appliances in the digital workflow. APOS TRENDS IN ORTHODONTICS 2019. [DOI: 10.25259/apos_78_2019] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
In this article, we demonstrate different approaches to enhance the integration of temporary anchorage devices in the digital workflow of the daily orthodontic practice. We describe methods of varying complexity which could be used depending on the equipment available in the orthodontic clinic.
Collapse
Affiliation(s)
- Simon Graf
- Private Orthodontic Practice, Smile AG, Belp, Bern, Switzerland,
| | - Ismaeel Hansa
- Department of Orthodontics, European University College, Dubai, UAE,
| |
Collapse
|
40
|
Kartal Y, Kaya B. Fixed Orthodontic Retainers: A Review. Turk J Orthod 2019; 32:110-114. [PMID: 31294414 DOI: 10.5152/turkjorthod.2019.18080] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2018] [Accepted: 12/25/2018] [Indexed: 11/22/2022]
Abstract
Orthodontic retention is defined as maintaining teeth in optimal aesthetic and functional position after treatment. Despite the necessity of retention phase and the factors influencing the stability of the teeth after orthodontic treatment was discussed by the orthodontist for a long time, it is accepted that a retention phase is essential for stability of orthodontic treatment results nowadays. Therefore, the application of a suitable retention method is important both for prevention of relapse after orthodontic treatment and for increasing patient satisfaction. Removable appliances had been used for many years for retention purposes. Later, fixed retainers were introduced to prevent relapse as having a number of advantages, such as better aesthetics, no need for patient cooperation, effectiveness, and suitability for lifelong retention. However, their need for precise bonding technique, fragility, and tendency to cause periodontal problems by weakening oral hygiene are some of their disadvantages.
Collapse
Affiliation(s)
- Yasemin Kartal
- Department of Orthodontics, Private Practice, Antalya, Turkey
| | - Burçak Kaya
- Department of Orthodontics, Başkent University School of Dentistry, Ankara, Turkey
| |
Collapse
|
41
|
Knaup I, Wagner Y, Wego J, Fritz U, Jäger A, Wolf M. Potential impact of lingual retainers on oral health: comparison between conventional twistflex retainers and CAD/CAM fabricated nitinol retainers. J Orofac Orthop 2019; 80:88-96. [PMID: 30778609 DOI: 10.1007/s00056-019-00169-7] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2018] [Accepted: 01/03/2019] [Indexed: 01/01/2023]
Affiliation(s)
- I Knaup
- Department of Orthodontics, Aachen RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany.
| | - Y Wagner
- Department of Orthodontics, Jena University Hospital, An der Alten Post 4, 07743, Jena, Germany
| | - J Wego
- Department of Orthodontics, Aachen RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany
| | - U Fritz
- Department of Orthodontics, Aachen RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany
| | - A Jäger
- Department of Orthodontics, Bonn University Hospital, Welschnonnenstr. 17, 53111, Bonn, Germany
| | - M Wolf
- Department of Orthodontics, Aachen RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany
| |
Collapse
|
42
|
Aycan M, Goymen M. Comparison of the different retention appliances produced using CAD/CAM and conventional methods and different surface roughening methods. Lasers Med Sci 2018; 34:287-296. [PMID: 30084028 DOI: 10.1007/s10103-018-2585-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2018] [Accepted: 07/06/2018] [Indexed: 11/30/2022]
Abstract
The purposes of this study are to conduct an in vitro comparison of the shear bond strength, breakage mode, and wire deformation of three different types of retainers and to compare the subsequent enamel surface changes. Two hundred seventy intact lower incisor teeth were embedded in acrylic blocks in pairs. Dead wire and CAD/CAM-fabricated and fiber-reinforced wires were applied to the teeth roughened with acid and Er:YAG or Er,Cr:YSGG laser. The surface roughness was observed by scanning electron and atomic force microscopy. The samples were analyzed for shear bonds. The dead wire and acid group were found to have the highest bonding strength and the strengths for all groups in which acid was used as an agent were found to be higher than others. Deformation of retainers was most noted in the dead wire-acid group. Among all the groups, the CAD/CAM-fabricated wire group showed the least deformation, with no deformation observed. In this study, it was determined that there is a significant correlation between ARI scores and agents. Consequently, acid etching was found to create more enamel surface roughness than laser groups. It was also seen that the combined use of the acid method and dead soft wire had the highest bond strength, even though it was not statistically significant. It was concluded that CAD/CAM-fabricated wire provides the opportunity for reuse in clinical applications due to its lack of deformation, being more conservative for the patient, and being more advantageous for the clinician in terms of session time, considering the residual adhesive amount left on the enamel surface.
Collapse
Affiliation(s)
- Merve Aycan
- Dentistry Faculty, Department of Orthodontics, Gaziantep University, 27060 Sehitkamil, Gaziantep, Turkey
| | - Merve Goymen
- Dentistry Faculty, Department of Orthodontics, Gaziantep University, 27060 Sehitkamil, Gaziantep, Turkey.
| |
Collapse
|
43
|
Möhlhenrich SC, Jäger F, Jäger A, Schumacher P, Wolf M, Fritz U, Bourauel C. Biomechanical properties of CAD/CAM-individualized nickel-titanium lingual retainers: an in vitro study. J Orofac Orthop 2018; 79:309-319. [PMID: 30014179 DOI: 10.1007/s00056-018-0144-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2017] [Accepted: 06/11/2018] [Indexed: 11/25/2022]
Abstract
PURPOSE This study aimed to determine and compare the mechanical properties of novel CAD/CAM(computer-aided design/manufacturing)-individualized nickel-titanium (NiTi) and conventional twisted wires. METHODS Seven NiTi wires (angular, 0.20 × 0.20 mm up to 0.50 × 0.50 mm) and two twisted steel wires (round, 0.40 mm and 0.44 mm) were investigated in three-point (3PBT) and four-point bending tests (4PBT) using the Orthodontic Measurement and Simulation System. All wires were loaded up to a distance of 3.3 mm, and resulting forces were measured. Additionally, in the biomechanical test (BMT), CAD/CAM-individualized NiTi retainers (0.35 × 0.35 mm) were subjected to intrusive and extrusive deformation of 0.1, 0.2, and 0.4 mm. RESULTS For twisted wires, typical plastic deformations were found in 3PBT (0.40 mm: 0.3 mm; 0.44 mm: 0.4 mm), and maximum resulting forces for these reached 1.3 N and 3.2 N for the 0.40 mm and 0.44 mm wires, respectively. Corresponding values in the 4PBT totaled 0.8 N for the 0.40 mm and 1.9 N for the 0.44 mm twisted wire. The NiTi samples showed plastic deformations in the 3PBT for the 0.25 × 0.25 mm dimension and in 4PBT for the 0.35 mm × 0.35 mm version. At a deflection of 1.5 mm, both tests revealed significantly different forces for the NiTi wires of different dimensions (p ≤ 0.001). In the BMT, no remarkable loading plateau or plastic deformation was observed. The resulting forces were significantly higher for extrusive than for intrusive deformation (p ≤ 0.001). CONCLUSIONS Individualized NiTi retainers feature specific elasticity and dimensional stability, and more deflection is necessary to achieve permanent deformations. The CAD/CAM production process did not significantly influence the biomechanical properties of the NiTi wires.
Collapse
Affiliation(s)
- Stephan Christian Möhlhenrich
- Department of Orthodontics and Dentofacial Orthopedics, University Hospital of the RWTH Aachen, Pauwelsstraße 30, 52074, Aachen, Germany.
| | - Fabian Jäger
- Department of Orthodontics and Dentofacial Orthopedics, University Hospital of the RWTH Aachen, Pauwelsstraße 30, 52074, Aachen, Germany
| | - Andreas Jäger
- Department of Orthodontics and Dentofacial Orthopedics, University of Bonn, Welschnonnenstraße 17, 53111, Bonn, Germany
| | | | - Michael Wolf
- Department of Orthodontics and Dentofacial Orthopedics, University Hospital of the RWTH Aachen, Pauwelsstraße 30, 52074, Aachen, Germany
| | - Ulrike Fritz
- Department of Orthodontics and Dentofacial Orthopedics, University Hospital of the RWTH Aachen, Pauwelsstraße 30, 52074, Aachen, Germany
| | - Christoph Bourauel
- Department of Oral Technology, University of Bonn, Welschnonnenstraße 17, 53111, Bonn, Germany
| |
Collapse
|
44
|
Gunay F, Oz AA. Clinical effectiveness of 2 orthodontic retainer wires on mandibular arch retention. Am J Orthod Dentofacial Orthop 2018; 153:232-238. [DOI: 10.1016/j.ajodo.2017.06.019] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2017] [Revised: 06/01/2017] [Accepted: 06/01/2017] [Indexed: 10/18/2022]
|