Bressi E, Sedláček K, Čurila K, Cano Ó, Luermans JGLM, Rijks JHJ, Meiburg R, Smits KC, Nguyen UC, De Ruvo E, Calò L, Kron J, Ellenbogen KA, Prinzen F, Vernooy K, Grieco D. Clinical impact and predictors of periprocedural myocardial injury among patients undergoing left bundle branch area pacing. J Interv Card Electrophysiol 2024; 67:2039-2050. [PMID: 38969963 DOI: 10.1007/s10840-024-01863-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/02/2024] [Accepted: 06/26/2024] [Indexed: 07/07/2024]
Abstract
BACKGROUND The clinical impact of Periprocedural myocardial injury (PMI) in patients undergoing permanent pacemaker implantation with Left Bundle Branch Area Pacing (LBBAP) is unknown. METHODS 130 patients undergoing LBBAP from January 2020 to June 2021 and completing 12 months follow up were enrolled to assess the impact of PMI on composite clinical outcome (CCO) defined as any of the following: all-cause death, hospitalization for heart failure (HHF), hospitalization for acute coronary syndrome (ACS) and ventricular arrhythmias (VAs). High sensitivity Troponin T (HsTnT) was measured up to 24-h after intervention to identify the peak HsTnT values. PMI was defined as increased peak HsTnT values at least > 99th percentile of the upper reference limit (URL: 15 pg/ml) in patients with normal baseline values. RESULTS PMI occurred in 72 of 130 patients (55%). ROC analysis yielded a post-procedural peak HsTnT cutoff of fourfold the URL for predicting the CCO (AUC: 0.692; p = 0.023; sensitivity 73% and specificity 71%). Of the enrolled patients, 20% (n = 26) had peak HsTnT > fourfold the URL. Patients with peak HsTnT > fourfold the URL exhibited a higher incidence of the CCO than patients with peak HsTnT ≤ fourfold the URL (31% vs. 10%; p = 0.005), driven by more frequent hospitalizations for ACS (15% vs. 3%; p = 0.010). Multiple (> 2) lead repositions attempts, the use of septography and stylet-driven leads were independent predictors of higher risk of PMI with peak HsTnT > fourfold the URL. CONCLUSIONS PMI seems common among patients undergoing LBBAP and may be associated with an increased risk of clinical outcomes in case of more pronounced (peak HsTnT > fourfold the URL) myocardial damage occurring during the procedure.
Collapse
Affiliation(s)
- Edoardo Bressi
- Department of Cardiovascular Sciences, Policlinico Casilino of Rome, Via Casilina, 1049, 00169, Rome, Italy.
- Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center, Maastricht, The Netherlands.
| | - Kamil Sedláček
- 1st Department of Internal Medicine - Cardiology and Angiology, Faculty of Medicine, University Hospital and Charles University, Hradec Králové, Czech Republic
| | - Karol Čurila
- Department of Cardiology, Cardiocenter, Third Faculty of Medicine, Charles University, University Hospital Kralovske Vinohrady, Prague, Czech Republic
| | - Óscar Cano
- Electrophysiology Section, Cardiology Department, Hospital Universitari I Politècnic La Fe, Área de Enfermedades Cardiovasculares, Valencia, Spain
- Centro de Investigaciones Biomédicas en RED en Enfermedades Cardiovasculares (CIBERCV), Madrid, Spain
| | - Justin G L M Luermans
- Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center, Maastricht, The Netherlands
| | - Jesse H J Rijks
- Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center, Maastricht, The Netherlands
| | - Roel Meiburg
- Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center, Maastricht, The Netherlands
| | - Karin C Smits
- Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center, Maastricht, The Netherlands
| | - Uyen Chau Nguyen
- Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center, Maastricht, The Netherlands
| | - Ermenegildo De Ruvo
- Department of Cardiovascular Sciences, Policlinico Casilino of Rome, Via Casilina, 1049, 00169, Rome, Italy
| | - Leonardo Calò
- Department of Cardiovascular Sciences, Policlinico Casilino of Rome, Via Casilina, 1049, 00169, Rome, Italy
| | - Jordana Kron
- Pauley Heart Center, Division of Cardiology, Department of Internal Medicine, Virginia Commonwealth University, Richmond, VA, USA
| | - Kenneth A Ellenbogen
- Pauley Heart Center, Division of Cardiology, Department of Internal Medicine, Virginia Commonwealth University, Richmond, VA, USA
| | - Frits Prinzen
- Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center, Maastricht, The Netherlands
| | - Kevin Vernooy
- Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center, Maastricht, The Netherlands
| | - Domenico Grieco
- Department of Cardiovascular Sciences, Policlinico Casilino of Rome, Via Casilina, 1049, 00169, Rome, Italy
| |
Collapse
|
2
|
Ponnusamy SS, Patel NR, Naperkowski A, Subzposh FA, Vijayaraman P. Cardiac troponin release following left bundle branch pacing. J Cardiovasc Electrophysiol 2021; 32:851-855. [PMID: 33484212 DOI: 10.1111/jce.14905] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Revised: 12/20/2020] [Accepted: 01/02/2021] [Indexed: 11/30/2022]
Abstract
Left bundle branch pacing (LBBP) has emerged as an alternative to His bundle pacing (HBP) to achieve physiologic ventricular stimulation. The extent of myocardial injury during permanent LBBP implantation is currently not known. The aim of the study was to prospectively assess the extent of myocardial injury during LBBP implantation. Cardiac troponin (cTn) levels were measured at baseline and 6-12 h following permanent LBBP. The number of attempts to achieve LBBP was documented. Troponin levels were measured in a control population undergoing other electrophysiology procedures including HBP, other devices involving right ventricular (RV) pacing, radiofrequency ablation for atrial fibrillation (AF) and supraventricular tachycardia (SVT). Significant elevation of troponin (SET) was defined as threefold increase above the upper reference limit (URL) for cTn. Between December 2019 and April 2020, 204 were prospectively enrolled: LBBP in 98 and Control group 106 (SVT, 55; AF, 20; HBP, 17; other devices, 14). SET (>3× URL) was seen in 49.4% of patients in the LBBP group compared to 58.4% in the control group (p = .23). Peak troponin levels were greater in the control group compared to the LBBP group (230.3 ± 320.1 vs. 87.4 ± 71.3 pg/ml; p = .0001). Compared to LBBP (49.4%), SET was observed less frequently following HBP (17.5%; p = .01), and other device implantation (29%; p = .15). Patients requiring >2 attempts (n = 33) had significantly higher incidence of SET compared to <2 attempts (n = 56; 66.7% vs. 39.3%; p = .01). LBBP implantation is associated with myocardial injury. Asymptomatic troponin release following LBBP is less than or comparable to other interventional electrophysiology procedures.
Collapse
Affiliation(s)
| | - Neil R Patel
- Division of Cardiology, The Wright Center, Scranton, Pennsylvania, USA
| | - Angela Naperkowski
- Division of Cardiology, Geisinger Heart Institute, Wilkes-Barre, Pennsylvania, USA
| | - Faiz A Subzposh
- Division of Cardiology, Geisinger Heart Institute, Wilkes-Barre, Pennsylvania, USA
| | | |
Collapse
|
3
|
Varvarousis D, Goulas N, Polytarchou K, Psychari SN, Paravolidakis K, Konstantinidou A, Tsoukalas D, Vlad D, Bouki K, Kotsakis A. Biomarkers of Myocardial Injury and Inflammation after Permanent Pacemaker Implantation: The Lead Fixation Type Effect. J Atr Fibrillation 2018; 10:1798. [PMID: 29988295 DOI: 10.4022/jafib.1798] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2017] [Revised: 01/19/2018] [Accepted: 02/14/2018] [Indexed: 11/10/2022]
Abstract
Background Permanent pacemaker implantation is accompanied by minor myocardial damage, indicated by elevated serum levels of cardiac biomarkers. Aim of this prospective study was to comparably investigate the lead fixation type effect on the extent of myocardial injury and inflammation following pacemaker implantation, and to assess the possible clinical implications. Methods Cardiac troponin I (cTnI) and C-reactive protein (CRP) were measured at baseline, 6 and 24h after implantation in 101 patients, categorized into the active and passive lead fixation group. Patients were followed up for clinical adverse events or abnormal pacing parameters at 24h, 7 and 30 days post-procedure. Results cTnI increased at 6h post-procedure (p<0.05) in 23.8% of patients, and returned to baseline after 24h. The passive group demonstrated significantly higher cTnI at 6h compared to the active group (p=0.006). CRP increased significantly at 6h, and maintained an upward trend after 24h (p<0.01) in both groups. The active group demonstrated significantly higher CRP at 6h compared to the passive group. We did not identify an association of positive biomarkers with adverse events. Conclusion cTnI and CRP can increase early after permanent pacemaker implantation, indicating mechanical myocardial injury and inflammation. The extent of these biomarkers elevation depends on the lead fixation type, and is not related to worse short-term prognosis.
Collapse
Affiliation(s)
- Dimitrios Varvarousis
- 2nd Department of Cardiology, General Hospital of Nikea-Piraeus "Agios Panteleimon", D. Mantouvalou 3, 18454, Piraeus, Greece
| | - Nikolaos Goulas
- 2nd Department of Cardiology, General Hospital of Nikea-Piraeus "Agios Panteleimon", D. Mantouvalou 3, 18454, Piraeus, Greece
| | - Kali Polytarchou
- 2nd Department of Cardiology, General Hospital of Nikea-Piraeus "Agios Panteleimon", D. Mantouvalou 3, 18454, Piraeus, Greece
| | - Stavroula N Psychari
- 2nd Department of Cardiology, General Hospital of Nikea-Piraeus "Agios Panteleimon", D. Mantouvalou 3, 18454, Piraeus, Greece
| | - Konstantinos Paravolidakis
- 2nd Department of Cardiology, General Hospital of Nikea-Piraeus "Agios Panteleimon", D. Mantouvalou 3, 18454, Piraeus, Greece
| | - Agapi Konstantinidou
- 2nd Department of Cardiology, General Hospital of Nikea-Piraeus "Agios Panteleimon", D. Mantouvalou 3, 18454, Piraeus, Greece
| | - Dionysios Tsoukalas
- 2nd Department of Cardiology, General Hospital of Nikea-Piraeus "Agios Panteleimon", D. Mantouvalou 3, 18454, Piraeus, Greece
| | - Delia Vlad
- 2nd Department of Cardiology, General Hospital of Nikea-Piraeus "Agios Panteleimon", D. Mantouvalou 3, 18454, Piraeus, Greece
| | - Konstantina Bouki
- 2nd Department of Cardiology, General Hospital of Nikea-Piraeus "Agios Panteleimon", D. Mantouvalou 3, 18454, Piraeus, Greece
| | - Athanasios Kotsakis
- 2nd Department of Cardiology, General Hospital of Nikea-Piraeus "Agios Panteleimon", D. Mantouvalou 3, 18454, Piraeus, Greece
| |
Collapse
|
4
|
Blažek P, Ferri-Certić J, Vražić H, Lennerz C, Grebmer C, Kaitani K, Karch M, Starčević B, Semmler V, Kolb C. Pacemaker Implantation Associated Myocardial Micro-Damage: A Randomised Comparison between Active and Passive Fixation Leads. Sci Rep 2018; 8:4870. [PMID: 29559697 PMCID: PMC5861101 DOI: 10.1038/s41598-018-23209-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2017] [Accepted: 03/07/2018] [Indexed: 12/24/2022] Open
Abstract
Fixation of the pacemaker leads during pacemaker implantation leads to an increase of cardiac Troponin T (cTnT) that can be interpreted as a sign of minimal myocardial damage. This trial evaluates whether the mechanism type of lead fixation influences the magnitude of cTnT release. Patients having a de-novo cardiac pacemaker implantation or a lead revision were centrally randomized to receive either a ventricular lead with an active (screw) or passive (tine) fixation mechanism. High-sensitive Troponin T (hsTnT) was determined on the day of the procedure beforehand and on the following day. 326 Patients (median age (IQR) 75.0 (69.0–80.0) years, 64% male) from six international centers were randomized to receive ventricular leads with an active (n = 166) or passive (n = 160) fixation mechanism. Median (IQR) hsTnT levels increased by 0.009 (0.004–0.021) ng/ml in the group receiving screw-in ventricular leads and by 0.008 (0.003–0.030) ng/ml in the group receiving tined ventricular leads (n.s.). In conclusion pacemaker implantations are followed by a release of hsTnT. The choice between active or passive fixation ventricular leads does not have a significant influence on the extent of myocardial injury and the magnitude of hsTnT release.
Collapse
Affiliation(s)
- Patrick Blažek
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Abteilung für Elektrophysiologie, Fakultät für Medizin der Technischen Universität München, Munich, Germany.
| | | | - Hrvoje Vražić
- University Hospital Dubrava, Division of Cardiology, Department of Internal Medicine, Zagreb, Croatia
| | - Carsten Lennerz
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Abteilung für Elektrophysiologie, Fakultät für Medizin der Technischen Universität München, Munich, Germany.,DZHK (German Centre for Cardiovascular Research), partner site Munich Heart Alliance, Munich, Germany
| | - Christian Grebmer
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Abteilung für Elektrophysiologie, Fakultät für Medizin der Technischen Universität München, Munich, Germany
| | | | - Martin Karch
- Klinikverbund Kempten-Oberallgäu, Abteilung für Kardiologie, Kempten, Germany
| | - Boris Starčević
- University Hospital Dubrava, Division of Cardiology, Department of Internal Medicine, Zagreb, Croatia
| | - Verena Semmler
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Abteilung für Elektrophysiologie, Fakultät für Medizin der Technischen Universität München, Munich, Germany
| | - Christof Kolb
- Deutsches Herzzentrum München, Klinik für Herz- und Kreislauferkrankungen, Abteilung für Elektrophysiologie, Fakultät für Medizin der Technischen Universität München, Munich, Germany
| |
Collapse
|
5
|
Follow-up of troponin I concentration in dogs with atrioventricular block and dual-chamber pacing in a case-matched study. J Vet Cardiol 2017; 19:247-255. [PMID: 28478942 DOI: 10.1016/j.jvc.2017.01.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2016] [Revised: 11/25/2016] [Accepted: 01/18/2017] [Indexed: 12/26/2022]
Abstract
BACKGROUND Increased cardiac troponin I (cTnI) concentration has been reported in dogs with atrioventricular (AV) block before and shortly following pacemaker implantation. The role of AV dyssynchrony, age, or concurrent cardiac disease on cTnI concentration remains unknown. OBJECTIVES To investigate change in cTnI concentration following dual-chamber pacemaker implantation on short- and long-term follow-up and to compare cTnI values to a case-matched control group. ANIMALS Thirty-eight client-owned dogs with permanent AV block and 38 matched control dogs. METHODS Retrospective review of medical records. Pacemaker group consisted of dogs with AV block and dual-chamber pacing. Control group matched the study population in age and cardiac disease. cTnI was compared between pacemaker and control group on short- and long-term follow-up. Different lead types and influence of arrhythmia on cTnI were tested. RESULTS cTnI was high at presentation (median 0.66 ng/ml; range 0.03-18.6) and showed a significant reduction over time after pacemaker implantation (p < 0.0001). Median cTnI values were significantly different between pacemaker and control group on short-term (p = 0.0004; 0.11 ng/ml, range 0.03-1.36 versus 0.06 ng/ml, range 0.03-0.46), but not on long-term follow-up (p = 0.0547; 0.14 ng/ml, range 0.03-0.73 versus 0.07 ng/ml, range 0.03-0.46). Lead type and severity of arrhythmia did not show a significant correlation to cTnI concentration. CONCLUSIONS On long-term follow-up, cTnI remained mildly elevated in some of the pacemaker dogs but was not significantly different to the matched control group.
Collapse
|
6
|
Chen X, Yu Z, Bai J, Hu S, Wang W, Qin S, Wang J, Sun Z, Su Y, Ge J. Troponin T elevation after permanent pacemaker implantation. J Interv Card Electrophysiol 2017; 49:211-218. [DOI: 10.1007/s10840-017-0247-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/07/2017] [Accepted: 03/29/2017] [Indexed: 10/19/2022]
|
7
|
Factors underlying elevated troponin I levels following pacemaker primo-implantation. Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub 2016; 160:248-56. [PMID: 26769435 DOI: 10.5507/bp.2015.067] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2015] [Accepted: 12/11/2015] [Indexed: 11/23/2022] Open
Abstract
BACKGROUND Cardiac troponins are routinely used as markers of myocardial damage. Originally, they were only intended for use in diagnosing acute coronary syndromes; however, we now know that raised serum troponin levels are not always caused by ischemia. There are many other clinical conditions that cause damage to cardiomyocytes, leading to raised levels of troponin. However, the specificity of cardiac troponins towards the myocardium is absolute. Our work focuses on mechanical damage to the myocardium and on monitoring the factors that raise the levels of cardiospecific markers after primo-implantation of a pacemaker with an actively fixed electrode. AIMS (i) To determine whether the use of a primo-implanted pacemaker with an electrode system with active fixation will raise troponin levels over baseline. (ii) To assess whether troponin I elevation is dependent on procedure complexity. METHODS We enrolled 219 consecutive patients indicated for pacemaker primo-implantation; cardiospecific marker values (troponin I, CKMB, myoglobin) were determined before the implantation procedure and again at 6- and 18-h intervals after the procedure. We monitored duration of cardiac skiascopy, number of attempts to place the electrode (active penetration into the tissue) and intervention range (single-chamber versus dual-chamber pacing), and we assessed the clinical data. RESULTS The average age of the enrolled patients was 78.2 ± 8.0 years (median age, 80 years); women constituted 45% of the group. We implanted 128 dual-chamber and 91 single-chamber devices with an average skiascopic time of 38.6 ± 22.0 s (median, 33.5 s). Troponin I serum levels increased from an initial 0.03 ± 0.07 μg/L (median, 0.01) to 0.18 ± 0.17 μg/L (median, 0.13) and 0.09 ± 0.18 μg/L (median, 0.04) at 6 and 18 h, respectively. The differences were statistically significant (P < 0.001 or P < 0.001). We confirmed a correlation between troponin increase and duration of skiascopy (P < 0.001). We also demonstrated a correlation between increased troponin I and number of attempts to place a pacemaker electrode (penetration into the tissue) at 6 h (P < 0.001) post-implantation. CONCLUSION We detected slightly elevated troponin I levels in patients with primo-implanted pacemakers using electrodes with active fixation. We demonstrated a direct correlation between myocardial damage (number of electrode penetrations into the myocardium) and troponin I elevation, as well as between complexity (severity) of the implantation procedure (indicated by prolonged skiascopy) and raised troponin I. The described phenomenon demonstrates the loss of the diagnostic role of troponin I early after pacemaker primo-implantation in patients with concomitant chest pain.
Collapse
|
8
|
Furniss G, Shi B, Jimenez A, Harding SA, Larsen PD. Cardiac troponin levels following implantable cardioverter defibrillation implantation and testing. Europace 2014; 17:262-6. [PMID: 25414480 DOI: 10.1093/europace/euu306] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
AIMS Previous studies have reported the defibrillation testing during implantable cardioverter defibrillator (ICD) implantation is associated with elevated cardiac biomarkers and ST-segment electrocardiogram (ECG) changes suggesting that shocks during testing may cause harm. However, the effects of testing have not been isolated from the implant procedure itself, where lead deployment may cause myocardial damage. This prospective study examined high sensitivity troponin T (hs-TnT) levels and ECG changes during ICD implanting alone, ICD implantation with testing and device testing as a stand-alone procedure. METHODS AND RESULTS We examined hs-TnT at baseline, and 6-8 h post procedure and 12 lead ECG at baseline, and 30 s, 5 min, and 10 min post right ventricle lead deployment and post defibrillation. There was no significant change in hs-TnT levels in a group of patients (n = 11) undergoing defibrillation testing alone, while hs-TnT was significantly elevated in patients undergoing implantation alone (n = 13, median increase 96%, P = 0.005) and in patients undergoing implantation and testing (n = 13, median increase 161%, P = 0.005). There was a significant correlation between the number of lead deployments and the percentage change in hs-TnT (r = -0.51, P = 0.01), but no correlation between either the number of shocks (r = 0.26, P = 0.25) or the total delivered energy (r = 0.24, P = 0.30) and percentage change in hs-TnT. CONCLUSION Implantation of ICD leads was associated with release of troponin, but we did not observe any evidence that ICD shocks alone cause myocardial injury.
Collapse
Affiliation(s)
- Guy Furniss
- Cardiology Department, Wellington Hospital, Wellington, New Zealand Wellington Cardiovascular Research Group, Wellington, New Zealand
| | - Bijia Shi
- Wellington Cardiovascular Research Group, Wellington, New Zealand University of Otago Wellington, PO Box 7343, Wellington, New Zealand
| | - Alejandro Jimenez
- Cardiology Department, Wellington Hospital, Wellington, New Zealand Wellington Cardiovascular Research Group, Wellington, New Zealand
| | - Scott A Harding
- Cardiology Department, Wellington Hospital, Wellington, New Zealand Wellington Cardiovascular Research Group, Wellington, New Zealand
| | - Peter D Larsen
- Wellington Cardiovascular Research Group, Wellington, New Zealand University of Otago Wellington, PO Box 7343, Wellington, New Zealand
| |
Collapse
|
9
|
|
10
|
Saravia SGM, Haberland A, Bartel S, Araujo R, Valda G, Reynaga DD, Ramirez ID, Borges AC, Wallukat G, Schimke I. Cardiac troponin T measured with a highly sensitive assay for diagnosis and monitoring of heart injury in chronic Chagas disease. Arch Pathol Lab Med 2011; 135:243-8. [PMID: 21284445 DOI: 10.5858/135.2.243] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
CONTEXT Chronic Chagas disease (15 million patients; annual incidence, 40, 000 patients; annual mortality, 12 ,500 patients) is the most serious parasitic disease in Latin America. Between 10 and 30 years after infection, 30% of patients with Chagas disease develop heart injury, which is the main reason for its high mortality. Consequently, frequent cardiac diagnostics are required for patients with Chagas disease. OBJECTIVE To minimize time-intensive and cost-intensive diagnostics, such as electrocardiography, echocardiography, and radiologic imaging, we tested the effect of measuring serum cardiac troponin T (cTnT) with a highly sensitive assay. To indicate the pathophysiologic background for cTnT release in Chagas heart injury, inflammation markers, such as C-reactive protein and interleukin 6, were measured in parallel. DESIGN Serum cTnT was measured in 26 healthy subjects and in 179 patients with chronic Chagas disease who were asymptomatic (indeterminate stage, n = 86), who were suffering from cardiomyopathy with or without megacolon (n = 71), or who were suffering from megacolon exclusively (n = 22). RESULTS Serum cTnT was significantly higher in patients with cardiomyopathy with or without megacolon than in healthy subjects, asymptomatic subjects, and patients with megacolon, and the cTnT value was correlated with the severity of the cardiomyopathy. The lower limit of detection for the highly sensitive assay (3 ng/L) was best at distinguishing patients with, and without, heart injury. C-reactive protein and interleukin 6 were found to parallel cTnT changes in both the different Chagas groups and the cardiomyopathy groups separated by disease severity. CONCLUSIONS Highly sensitive cTnT measurement has the potential to contribute to diagnosis and monitoring of heart injury in patients with chronic Chagas disease. The highly sensitive assay of cTnT release seems to be related to Chagas heart disease-specific inflammation.
Collapse
|
11
|
Gustavsson CG, Nilson M. Troponin I and Creatine Kinase MB do not provide comparable information after PCI. SCAND CARDIOVASC J 2010; 45:21-6. [PMID: 21114454 DOI: 10.3109/14017431.2010.536989] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
OBJECTIVES To compare cardiac troponin I (cTnI) and creatine kinase-MB (CK-MB) after PCI in cases with normal baseline levels of both biomarkers. DESIGN cTnI and CK-MB after PCI were stratified as multiples of the 99(th) percent upper reference limit (99%URL) and compared to each other in 489 patients. Post-PCI levels > three times 99%URL were classified as procedure-related infarctions. Results. After PCI, CK-MB was > 3x 99%URL in 58/486 patients (12%) and cTnI > 3x 99%URL in 292/487 patients (60%). cTnI was > 10x 99%URL in all cases with infarction according to CK-MB but CK-MB was often normal despite elevated cTnI. There was an only minimal overlap between two infarction populations, those with cTnI in the range from 1x to 10x 99%URL and those with CK-MB 1x to 10x 99%URL. CONCLUSIONS With the present quantification scales, infarction rate after PCI is > five-fold higher with cTnI than with CK-MB.
Collapse
|
12
|
Trafny DJ, Oyama MA, Wormser C, Reynolds CA, Singletary GE, Peddle GD. Cardiac troponin-I concentrations in dogs with bradyarrhythmias before and after artificial pacing. J Vet Cardiol 2010; 12:183-90. [PMID: 21030328 DOI: 10.1016/j.jvc.2010.07.002] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2010] [Revised: 07/22/2010] [Accepted: 07/23/2010] [Indexed: 10/18/2022]
Abstract
OBJECTIVES To quantify cardiac troponin-I (cTnI) concentration in dogs with symptomatic bradyarrhythmias before and after artificial pacing and to correlate cTnI concentration with diagnosis, echocardiographic parameters, serology, and outcome. ANIMALS, MATERIALS AND METHODS Medical records from the University of Pennsylvania from 2006 to 2009 were reviewed, and 14 dogs with cTnI assay results before and after pacemaker were identified. The ECG diagnosis included complete atrioventricular block (AVB), sick sinus syndrome, 2nd degree AVB, and atrial standstill. Serology, presence of premature beats, echocardiographic measurements, and pacing modality were recorded. RESULTS Mean cTnI concentration was elevated both pre- and post-pacing, and was significantly higher pre-pacing vs. post-pacing. Post-pacing cTnI concentration in 9 of 14 dogs (64%) remained above the reference range. Four dogs yielded high serum titers for Bartonella spp. Four dogs with markedly increased cTnI concentration had progressive left ventricular enlargement and myocardial failure as compared to pre-pacing examination. CONCLUSIONS Elevated cTnI concentration suggests that cardiac injury persists after artificial pacing in dogs with bradyarrhythmias. Myocarditis secondary to Bartonella spp. or other causes may be an important cause of AVB in dogs. Prospective studies investigating the correlation of cTnI to potential etiology and development of post-pacing LV dysfunction and outcome are needed.
Collapse
Affiliation(s)
- Dennis J Trafny
- Department of Clinical Studies-Philadelphia, School of Veterinary Medicine, University of Pennsylvania, MJR-VHUP-Cardiology, 3900 Delancey St., Philadelphia, PA 19104, United States
| | | | | | | | | | | |
Collapse
|