1
|
Isonaga Y, Miyazaki S, Nitta J, Shirai Y, Inamura Y, Sagawa Y, Yamauchi Y, Sasaki T, Inaba O, Sasano T. Acute procedural efficacy and safety of a novel expandable diameter cryoballoon in atrial fibrillation ablation: Early results from a multicenter ablation registry. J Cardiovasc Electrophysiol 2024; 35:198-205. [PMID: 38037864 DOI: 10.1111/jce.16135] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Revised: 10/31/2023] [Accepted: 11/06/2023] [Indexed: 12/02/2023]
Abstract
INTRODUCTION The major limitation of the current cryoballoon (CB) system is a fixed 28 mm balloon-size. We sought to analyze real-world early experience with novel-sized adjustable CB. METHODS This multicenter observational study included 140 consecutive atrial fibrillation patients (71 years, 94 men, 86 paroxysmal) who underwent pulmonary vein (PV) isolation using expandable diameter CB capable of ablation at 28 or 31 mm. RESULTS Out of 544 targeted PVs, 526 (96.7%) were successfully isolated by a size-adjustable CB with a 770 [690-870] second median application dose, while the remaining 18 required touch-up ablation. Among them, 326 (62.0%) PVs were isolated by a 31 mm balloon, and the rate was significantly higher for upper than lower PVs (73.0% vs. 45.7%, p < .0001) and highest for right superior (78.5%) and lowest for right inferior (39.9%) PVs. The biophysical parameters and time to isolation were comparable between the 28 and 31 mm balloons, however, the real-time PV potential monitoring capability was significantly higher for 31 mm than 28 mm balloons for the left superior PV. The esophageal temperature reached 15°C during left inferior PV ablation significantly more often with 31 mm than 28 mm balloons (43.1% vs. 18.2%, p = .008). Right phrenic nerve injury (PNI) occurred in 9 (6.4%) patients during applications (6 right superior, 2 right inferior PVs), and most occurred with a 31 mm balloon. CONCLUSIONS Our real-world early data demonstrated high acute efficacy and safety of the novel-sized adjustable CB. The biophysical parameters were similar between the 28 and 31 mm balloons. No marked decrease in the incidence of PNI was observed even with 31 mm balloons.
Collapse
Affiliation(s)
- Yuhei Isonaga
- Department of Cardiology, Japanese Red Cross Saitama Hospital, Saitama, Japan
| | - Shinsuke Miyazaki
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan
| | - Junichi Nitta
- Department of Cardiology, Sakakibara Heart Institute, Tokyo, Japan
| | - Yasuhiro Shirai
- Department of Cardiology, Disaster Medical Center, Tokyo, Japan
| | - Yukihiro Inamura
- Department of Cardiology, Japanese Red Cross Saitama Hospital, Saitama, Japan
| | - Yuichiro Sagawa
- Department of Cardiology, Japanese Red Cross Yokohama City Bay Hospital, Yokohama, Kanagawa, Japan
| | - Yasuteru Yamauchi
- Department of Cardiology, Japanese Red Cross Yokohama City Bay Hospital, Yokohama, Kanagawa, Japan
| | - Takeshi Sasaki
- Department of Cardiology, Disaster Medical Center, Tokyo, Japan
| | - Osamu Inaba
- Department of Cardiology, Japanese Red Cross Saitama Hospital, Saitama, Japan
| | - Tetsuo Sasano
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan
| |
Collapse
|
2
|
Kim JA, Chelu MG. Comparison of cryoballoon and radiofrequency ablation for persistent atrial fibrillation: a systematic review and meta-analysis. J Interv Card Electrophysiol 2022; 66:585-595. [PMID: 36089635 DOI: 10.1007/s10840-022-01369-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Accepted: 09/05/2022] [Indexed: 11/29/2022]
Abstract
BACKGROUND There is limited data comparing radiofrequency (RF) and cryoballoon (CB) ablation for persistent atrial fibrillation (AF), which tends to have higher recurrence rates following ablation compared to paroxysmal AF. METHODS A systematic search of the Embase, PubMed, and Cochrane database was performed for studies comparing RF vs CB ablation for persistent AF. An inverse-variance random-effects model was used to calculate the composite effects. RESULTS One randomized and 9 observational studies were identified, with 1650 patients receiving CB and 1706 patients receiving RF ablation. Mean follow-up time ranged from 12 to 48 months. Freedom from recurrent atrial tachyarrhythmia was similar with the two modalities (HR 0.93, 95% CI 0.80 to 1.08, I2 0%). Total complications were similar in both groups (RR 1.05, 95% CI 0.73 to 1.53, I2 0%) although rates of phrenic nerve palsy (PNP) were greater with CB (RR 4.13, 95% CI 1.49 to 11.46, I2 0%). Shorter procedure times were observed with CB (mean reduction 43.77 min, 95% CI 66.45 to 21.09 min, I2 96%) with no difference in fluoroscopy time (mean difference 0.82 min, 95% CI - 11.92 to 13.55 min, I2 100%). CONCLUSIONS In persistent AF patients, CB ablation has similar efficacy and overall safety as compared to RF ablation. While CB is associated with significantly shorter procedure times, the improved procedural efficiency with CB is offset by increased rates of PNP and the potential need for touch-up RF ablation.
Collapse
Affiliation(s)
- Jitae A Kim
- Department of Internal Medicine, Baylor College of Medicine, Houston, TX, USA
| | - Mihail G Chelu
- Division of Cardiology, Baylor College of Medicine, 7200 Cambridge Suite A6.137, MS: BCM621, Houston, TX, 77030, USA.
- Baylor St. Luke's Medical Center, Houston, TX, USA.
- Texas Heart Institute, Houston, TX, USA.
| |
Collapse
|
3
|
Chen YL, Wang HT, Chen HC, Liu WH, Hsueh S, Chung WJ, Wu PJ, Liu CH, Chung CM, Lin YS. A risk stratification scoring system for new-onset atrial fibrillation after ischemic stroke: A National cohort study. Medicine (Baltimore) 2020; 99:e20881. [PMID: 32629677 PMCID: PMC7337555 DOI: 10.1097/md.0000000000020881] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Atrial fibrillation (AF) is a major independent risk factor of stroke and anticoagulation therapy is needed in patients with AF after ischemic stroke. However, the detection rate of AF is low after ischemic stroke. Developing a prediction model for newly diagnosed AF after ischemic stroke will help to assess the subclinical AF.We identified 98,103 patients with diabetes mellitus (DM) and 261,893 patients without DM, who were not AF history and admitted for newly ischemic stroke from the National Health Insurance Research Database in Taiwan. The prediction model for 3-year incidence of AF after ischemic stroke was derived from multivariate logistic regression and also the accuracy rate of the prediction model was compared with CHA2DS2-VASC and CHADS2 scores as a reference.Four thousand nine hundred seventy six patients in the DM cohort and 16,127 patients in the non-DM cohort developed AF during 3 years of follow-up. The variables in the point-based prediction model for non-DM patients (range: -3-28), included age, heart failure, coronary artery disease, gout, obstructive pulmonary disease, hypertension, female, and statin use, while those for DM patients (range: -2-30) included age, heart failure, coronary artery disease, chronic kidney disease, hypertension, obstructive pulmonary disease, and statin use. Compared to the CHADS2 and CHA2DS2-VASc scoring systems, this scoring system was better at predicting 3-year risk of AF after ischemic stroke in both cohorts.This model might be useful in evaluating the benefit of insertable cardiac monitor implantation and anticoagulation agents in individual patients after ischemic stroke.
Collapse
Affiliation(s)
- Yung-Lung Chen
- Division of Cardiology and Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine
- Graduate Institute of Clinical Medical Sciences, College of Medicine, Chang Gung University
| | - Hui-Ting Wang
- Emergency Department, Kaohsiung Chang Gung Memorial Hospital
| | - Huang-Chung Chen
- Division of Cardiology and Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine
| | - Wen-Hao Liu
- Division of Cardiology and Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine
| | - Shukai Hsueh
- Division of Cardiology and Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine
| | - Wen-Jung Chung
- Division of Cardiology and Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine
| | - Po-Jui Wu
- Division of Cardiology and Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine
| | - Chi-Hung Liu
- Stroke Center and Department of Neurology, Chang Gung Memorial Hospital, Linkou Medical Center, Chang Gung University College of Medicine, Taoyuan
| | - Chang-Ming Chung
- Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Chiayi, Taiwan, Chang Gung University College of Medicine, Taiwan
| | - Yu-Sheng Lin
- Graduate Institute of Clinical Medical Sciences, College of Medicine, Chang Gung University
- Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Chiayi, Taiwan, Chang Gung University College of Medicine, Taiwan
| |
Collapse
|
4
|
Okishige K, Kawaguchi N, Iwai S, Yamauchi Y, Keida T, Sasano T, Hirao K, Valderrabano M. Comparative Study of Cryoballoon versus Radiofrequency for Pulmonary Vein Isolation when Combined with vein of Marshall Ethanol Infusion for Paroxysmal Atrial Fibrillation. J Atr Fibrillation 2020; 12:2253. [PMID: 32435354 DOI: 10.4022/jafib.2253] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2019] [Revised: 12/12/2019] [Accepted: 01/11/2020] [Indexed: 01/08/2023]
Abstract
Introduction Ethanol infusion (EI) in the vein of Marshall (VOM) has multifactorial effects that could be synergistic to pulmonary vein isolation (PVI) in ablation of atrial fibrillation (AF). The efficacy of radiofrequency (RF) versus cryoablation when combined with a VOM-EI has never been investigated. The aim of this study is to evaluate outcome differences of AF ablation using RF versus cryoablation when combined with a VOM-EI. Materials and Methods Consecutive patients (n=132) underwent catheter ablation of paroxysmal AF with either RF or cryoballoon (CB) for PVI combined with VOM-EI. Bi-directional conduction block at the mitral isthmus was attempted. The end-point was the freedom from any atrial arrhythmias documented after a blanking period of 90 days after the procedure. Results Kaplan-Meier estimates of the arrhythmia-free survival after 1 year were 63.8 (RF + VOM), and 82.7 % (CB + VOM), respectively. Comparison between CB + VOM versus RF + VOM reached a significance (p=0.0292). The periprocedural complication rate was comparable in both groups (5.0 % RF, 5.8 % CB; p=0.14) with a significant difference in the incidence of phrenic nerve palsy (0 % RF, 2.0 % CB; p<0.05). Conclusions PVI with a CB had an increased freedom from AF recurrence compared to RF combined with VOM-EI. The present results suggest a potential additive effect of a VOM-EI to CB application.
Collapse
Affiliation(s)
- Kaoru Okishige
- Heart Center, Japan Red Cross Yokohama City Bay Hospital, Yokohama, Japan.,Division of Cardiology, Edogawa Hospital.,Arrhythmia Center, Tokyo Medical and Dental University.,Division of Cardiac Electrophysiology, Methodist DeBakey Heart and Vascular Center and Houston Methodist Research Institute, Houston, TX
| | - Naohiko Kawaguchi
- Heart Center, Japan Red Cross Yokohama City Bay Hospital, Yokohama, Japan.,Division of Cardiology, Edogawa Hospital.,Arrhythmia Center, Tokyo Medical and Dental University.,Division of Cardiac Electrophysiology, Methodist DeBakey Heart and Vascular Center and Houston Methodist Research Institute, Houston, TX
| | - Shinsuke Iwai
- Heart Center, Japan Red Cross Yokohama City Bay Hospital, Yokohama, Japan.,Division of Cardiology, Edogawa Hospital.,Arrhythmia Center, Tokyo Medical and Dental University.,Division of Cardiac Electrophysiology, Methodist DeBakey Heart and Vascular Center and Houston Methodist Research Institute, Houston, TX
| | | | | | - Tetsuo Sasano
- Arrhythmia Center, Tokyo Medical and Dental University
| | - Kenzo Hirao
- Division of Cardiac Electrophysiology, Methodist DeBakey Heart and Vascular Center and Houston Methodist Research Institute, Houston, TX
| | - Miguel Valderrabano
- Heart Center, Japan Red Cross Yokohama City Bay Hospital, Yokohama, Japan.,Division of Cardiology, Edogawa Hospital.,Arrhythmia Center, Tokyo Medical and Dental University.,Division of Cardiac Electrophysiology, Methodist DeBakey Heart and Vascular Center and Houston Methodist Research Institute, Houston, TX
| |
Collapse
|
5
|
Aksu T, Yalin K, Guler TE, Bozyel S, Heeger CH, Tilz RR. Acute Procedural Complications of Cryoballoon Ablation: A Comprehensive Review. J Atr Fibrillation 2019; 12:2208. [PMID: 32435335 DOI: 10.4022/jafib.2208] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Revised: 08/14/2019] [Accepted: 08/26/2019] [Indexed: 12/15/2022]
Abstract
Catheter ablation is increasingly performed for treatment of atrial fibrillation (AF). Balloon based procedures have been developed aiming at safer, easier and more effective treatment as compared to point to point ablation. In the present review article, we aimed to discuss acute procedural complications of cryoballoon ablation.
Collapse
Affiliation(s)
- Tolga Aksu
- Department of Cardiology, University of Health Sciences, Kocaeli Derince Training and Research Hospital, Kocaeli, Turkey
| | - Kivanc Yalin
- Istanbul University- Cerrahpasa, Faculty of Medicine, Department of Cardiology, Istanbul, Turkey.,University Heart Center Lübeck, Medical Clinic II (Cardiology/Angiology/Intensive Care Medicine), University Hospital Schleswig-Holstein, Lübeck, Germany
| | - Tumer Erdem Guler
- Department of Cardiology, University of Health Sciences, Kocaeli Derince Training and Research Hospital, Kocaeli, Turkey
| | - Serdar Bozyel
- Department of Cardiology, University of Health Sciences, Kocaeli Derince Training and Research Hospital, Kocaeli, Turkey
| | - Christian-H Heeger
- University Heart Center Lübeck, Medical Clinic II (Cardiology/Angiology/Intensive Care Medicine), University Hospital Schleswig-Holstein, Lübeck, Germany
| | - Roland R Tilz
- University Heart Center Lübeck, Medical Clinic II (Cardiology/Angiology/Intensive Care Medicine), University Hospital Schleswig-Holstein, Lübeck, Germany
| |
Collapse
|
6
|
Zhang J, Sun H, He K, Gu J, Zheng R, Shao Y. Hybrid ablation versus transcatheter ablation for atrial fibrillation: A meta-analysis. Medicine (Baltimore) 2019; 98:e14053. [PMID: 30653113 PMCID: PMC6370058 DOI: 10.1097/md.0000000000014053] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
BACKGROUND Despite the successful creation of complex lesion sets during hybrid ablation (HA), reoccurrence of atrial fibrillation (AF), and/or atrial arrhythmia and procedural complications still occur. The main objective of this study was to compare the efficacy and safety between HA and transcatheter ablation (TA). METHODS We searched Pubmed, Embase, and the Cochrane Central Register of Controlled Trials (CENTRAL) database up to October 2017. Studies that satisfied our predefined inclusion criteria were included. Of the 894 records, 4 studies encompassing 331 patients were included in our study. We assessed pooled data using random-effect or fixed-effect model. The main endpoint was freedom of atrial arrhythmia after follow-up duration, secondary results were procedure time and intraoperative and postoperative adverse events. Similarly, tertiary outcomes were endocardial time, fluoroscopy time, and postoperative hospitalization. RESULTS Compared with TA, HA treatment through mini-thoracotomy access improved superiority in freedom of atrial arrhythmia after follow-up duration (odds ratio [OR] = 6.67, 95% confidence interval [CI]: 2.63-16.90), but HA increased the incidence of intraoperative and postoperative adverse events for AF patients (OR = 2.98, 95% CI: 1.30-6.83). HA through either mini-thoracotomy or transdiaphragmatic/subxiphoid access had longer procedure time and postoperative hospitalization than TA. However, endocardial time was shorter than TA. CONCLUSIONS For AF patients, HA possessed of an overall superior outcome using mini-thoracotomy way to TA. Although HA had longer procedure time, it yielded a reduction in endocardial time. Meanwhile, we should pay attention to the significantly high risk of intraoperative and postoperative adverse events that the HA generated.
Collapse
Affiliation(s)
- Junjie Zhang
- Department of Cardiothoracic Surgery, Changzhou Wujin People's Hospital, Jiangsu
- The First Clinical Medical School of Nanjing Medical University, Nanjing, China
| | - Haoliang Sun
- Department of Cardiovascular Surgery, The First Affiliated Hospital of Nanjing Medical University, Jiangsu Province Hospital
| | - Keshuai He
- The First Clinical Medical School of Nanjing Medical University, Nanjing, China
| | - Jiaxi Gu
- Department of Cardiovascular Surgery, The First Affiliated Hospital of Nanjing Medical University, Jiangsu Province Hospital
| | - Rui Zheng
- Department of Cardiovascular Surgery, The First Affiliated Hospital of Nanjing Medical University, Jiangsu Province Hospital
| | - Yongfeng Shao
- Department of Cardiovascular Surgery, The First Affiliated Hospital of Nanjing Medical University, Jiangsu Province Hospital
| |
Collapse
|
7
|
Yubing W, Yanping X, Zhiyu L, Weijie C, Li S, Huaan D, Peilin X, Zengzhang L, Yuehui Y. Long-term outcome of radiofrequency catheter ablation for persistent atrial fibrillation. Medicine (Baltimore) 2018; 97:e11520. [PMID: 30024535 PMCID: PMC6086529 DOI: 10.1097/md.0000000000011520] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Catheter ablation has been wildly used to treat atrial fibrillation (AF) and has achieved a better efficacy for paroxysmal AF (PAF) but not for persistent AF (PerAF). Furthermore, a few data on the efficacy and safety of catheter ablation for PerAF were reported. This study aimed to investigate long-term efficacy of radiofrequency catheter ablation (RFCA) for PerAF and explore predictors of late recurrence of atrial fibrillation (LRAF).A total of 92 consecutive patients with PerAF (64 males, aged 56.42 ± 11.24 years) were enrolled in this study and accepted circumferential pulmonary vein isolation (CPVI) alone or CPVI combined additional ablation.Maintenance rate of sinus rhythm (SR) was 40.2% after a single procedure with median follow-up of 15 months and 52.2% after mean 1.3 ± 0.6 procedures with median follow-up of 26 months. Long-term SR maintenance rate was no statistical difference between patients with CPVI alone and with CPVI combined additional ablation (48.6% vs 35.1%, log rank test, P = .152). Patients with AF duration < 24 months had a higher long-term SR maintenance rate than those with AF duration ≥ 24 months (55.6% vs 30.4%, log rank test, P = .022). AF duration (OR = 1.015, 95%CI 1.001-1.030, P = .015), and early recurrence of AF (ERAF) (OR = 10.654, 95%CI 3.853-29.460, P < .001) were predictors of LRAF after a single procedure.In conclusion, long-term maintenance SR rate was 52.2% in patients with PerAF after multiple procedures with a median over 2-year follow-up. Patients with AF duration < 24 months had better outcome. AF duration and ERAF were predictors of LRAF after a single procedure.
Collapse
Affiliation(s)
- Wang Yubing
- Department of Cardiology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing Cardiac Arrhythmia Service Center, Chongqing
- Affiliated Hospital of North Sichuan Medical College, Sichuan, China
| | - Xu Yanping
- Department of Cardiology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing Cardiac Arrhythmia Service Center, Chongqing
| | - Ling Zhiyu
- Department of Cardiology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing Cardiac Arrhythmia Service Center, Chongqing
| | - Chen Weijie
- Department of Cardiology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing Cardiac Arrhythmia Service Center, Chongqing
| | - Su Li
- Department of Cardiology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing Cardiac Arrhythmia Service Center, Chongqing
| | - Du Huaan
- Department of Cardiology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing Cardiac Arrhythmia Service Center, Chongqing
| | - Xiao Peilin
- Department of Cardiology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing Cardiac Arrhythmia Service Center, Chongqing
| | - Liu Zengzhang
- Department of Cardiology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing Cardiac Arrhythmia Service Center, Chongqing
| | - Yin Yuehui
- Department of Cardiology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing Cardiac Arrhythmia Service Center, Chongqing
| |
Collapse
|
8
|
Safety and efficacy of persistent atrial fibrillation ablation using the second-generation cryoballoon. Clin Res Cardiol 2018; 107:570-577. [PMID: 29492703 DOI: 10.1007/s00392-018-1219-1] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/17/2017] [Accepted: 02/19/2018] [Indexed: 10/17/2022]
Abstract
BACKGROUND The second-generation cryoballoon (CB) is increasingly used for treatment of persistent atrial fibrillation (AF). Data regarding the clinical outcome and mechanism of arrhythmia recurrence following persistent AF ablation using CB is sparse. In this study, we aimed to assess the efficacy of CB and mechanisms of atrial tachyarrhythmia (ATA) recurrence in patients with persistent AF. METHODS AND RESULTS A total of 133 patients (66 ± 10 years, 60% male) with symptomatic persistent AF, who were scheduled for PVI using the second-generation CB were enrolled. Follow-up included 24 h Holter recording at 3, 6 and 12 months. Any documented episode of ATA lasting more than 30 s was considered as a recurrent arrhythmic event. All targeted veins were isolated (100%). Phrenic nerve palsy with recovery during follow-up occurred in six patients (4.5%), no patient experienced tamponade or a cerebrovascular event. During 12.6 ± 5.4 months of follow-up, 89/133 (67%) patients were free of ATA recurrences. Multivariable analysis revealed recurrence in the blanking period (HR 11.46, 0.95 CI 3.92-33.49, p < 0.001), presence of cardiomyopathy (HR 2.75, 0.95 CI 1.09-6.96, p = 0.032) and PV abnormality (HR 3.56, 0.95 CI 1.21-10.43, p = 0.021) as predictors for late recurrence. CONCLUSION In patients with persistent AF, second-generation cryoballoon use is associated with an excellent safety profile and favorable outcomes. Arrhythmia recurrence during the blanking period, presence of cardiomyopathy and PV abnormality were independent predictors of long-term AF recurrence.
Collapse
|