1
|
Osaki MH, Osaki TH, Garcia DM, Osaki T, Gameiro G, Belfort R, Cruz AAV. An objective tool to measure the effect of botulinum toxin in blepharospasm and hemifacial spasm. Eur J Neurol 2020; 27:1487-1492. [DOI: 10.1111/ene.14258] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2020] [Accepted: 04/07/2020] [Indexed: 11/27/2022]
Affiliation(s)
- M. H. Osaki
- Department of Ophthalmology Paulista School of Medicine Federal University of São Paulo São Paulo SP Brazil
- Osaki Clinics São Paulo SP Brazil
| | - T. H. Osaki
- Department of Ophthalmology Paulista School of Medicine Federal University of São Paulo São Paulo SP Brazil
- Osaki Clinics São Paulo SP Brazil
| | - D. M. Garcia
- Department of Ophthalmology, Otorhinolaryngology and Head and Neck Surgery University of São Paulo/Ribeirão Preto Ribeirão Preto SP Brazil
| | - T. Osaki
- Department of Ophthalmology Paulista School of Medicine Federal University of São Paulo São Paulo SP Brazil
- Osaki Clinics São Paulo SP Brazil
| | - G. Gameiro
- Department of Ophthalmology Paulista School of Medicine Federal University of São Paulo São Paulo SP Brazil
| | - R. Belfort
- Department of Ophthalmology Paulista School of Medicine Federal University of São Paulo São Paulo SP Brazil
| | - A. A. V. Cruz
- Department of Ophthalmology, Otorhinolaryngology and Head and Neck Surgery University of São Paulo/Ribeirão Preto Ribeirão Preto SP Brazil
| |
Collapse
|
2
|
Osaki TH, Osaki MH, Garcia DM, Osaki T, Ohkawara L, Belfort R, Cruz AAV. Evaluation of botulinum toxin effects in hemifacial spasm patients: correlation between clinical rating scales and high-speed video system measurements. J Neural Transm (Vienna) 2020; 127:1041-1046. [PMID: 32232566 DOI: 10.1007/s00702-020-02183-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2019] [Accepted: 03/24/2020] [Indexed: 10/24/2022]
Abstract
The purpose of this study was to compare the scores of two clinical rating scales and high-speed video system measurements obtained during spontaneous eyelid movements in hemifacial spasm (HFS) patients before and after treatment. Patients were evaluated before and 30 days after receiving treatment with onabotulinumtoxinA injections. Using a high-speed video system, the eyelid movements were recorded bilaterally for 3 min and the energy power generated by the upper eyelid during spontaneous eyelid movements was assessed before and after treatment. The scores of the Jankovic rating scale (JRS) and Hemifacial Spasm Grading System (HSGS) were also assessed before and after treatment. The authors studied 22 patients. Significant reduction in JRS and HSGS scores and in the energy generated by the upper eyelid was observed after treatment. A power spectrum of less than 23,000 was associated with JRS and HSGS scores less than 4 and 6.25, respectively and a power spectrum greater than or equal to 23,000 was associated with JRS and HSGS scores greater than or equal to 4 and 6.25, respectively (p < 0.0001 and p = 0.0025). Rating systems are easy to use, but they may exhibit limitations in sensitivity to assess differences between distinct disease patterns and between subtle differences in treatment responses. The high-speed video system permits a greater degree of accuracy, which allows for the assessment of differences in eyelid movement patterns and would permit better tailoring of treatment to patients. However, simpler devices employing this system would need to be developed, so that it could be used in clinical practice.
Collapse
Affiliation(s)
- Tammy H Osaki
- Department of Ophthalmology and Visual Sciences, Paulista School of Medicine, Federal University of Sao Paulo-EPM/UNIFESP, São Paulo, SP, Brazil
- Department of Ophthalmology, University of Santo Amaro, São Paulo, SP, Brazil
- Osaki Clinics, R. Vergueiro, 2045 cj. 1009, São Paulo, SP, 04101-000, Brazil
| | - Midori H Osaki
- Department of Ophthalmology and Visual Sciences, Paulista School of Medicine, Federal University of Sao Paulo-EPM/UNIFESP, São Paulo, SP, Brazil.
- Osaki Clinics, R. Vergueiro, 2045 cj. 1009, São Paulo, SP, 04101-000, Brazil.
| | - Denny M Garcia
- Department of Ophthalmology, Otorhinolaryngology and Head and Neck Surgery, University of S. Paulo/Ribeirão Preto, Ribeirão Preto, SP, Brazil
| | - Teissy Osaki
- Department of Ophthalmology and Visual Sciences, Paulista School of Medicine, Federal University of Sao Paulo-EPM/UNIFESP, São Paulo, SP, Brazil
- Osaki Clinics, R. Vergueiro, 2045 cj. 1009, São Paulo, SP, 04101-000, Brazil
| | - Lilian Ohkawara
- Department of Ophthalmology and Visual Sciences, Paulista School of Medicine, Federal University of Sao Paulo-EPM/UNIFESP, São Paulo, SP, Brazil
| | - Rubens Belfort
- Department of Ophthalmology and Visual Sciences, Paulista School of Medicine, Federal University of Sao Paulo-EPM/UNIFESP, São Paulo, SP, Brazil
| | - Antonio Augusto V Cruz
- Department of Ophthalmology, Otorhinolaryngology and Head and Neck Surgery, University of S. Paulo/Ribeirão Preto, Ribeirão Preto, SP, Brazil
| |
Collapse
|