1
|
Koitschev A, Neudert M, Lenarz T. [Transcutaneous bone conduction implant with self-drilling screws : A new method for fixation of an active transcutaneous bone conduction implant. German version]. HNO 2024; 72:554-560. [PMID: 37106143 DOI: 10.1007/s00106-023-01294-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/11/2023] [Indexed: 04/29/2023]
Abstract
BACKGROUND The active transcutaneous bone conduction implant (tBCI; BONEBRIDGE™ BCI 601; MED-EL, Innsbruck, Austria) is fixed to the skull with two self-tapping screws in predrilled screw channels. The aim of this prospective study was to evaluate the safety and effectiveness of fixation with self-drilling screws instead of the self-tapping screws, in order to simplify the surgical procedure. MATERIALS AND METHODS Nine patients (mean age 37 ± 16 years, range 14-57 years) were examined pre- and 12 months postoperatively for word recognition scores (WRS) at 65 dB SPL, sound-field (SF) thresholds, bone conduction thresholds (BC), health-related quality of life (Assessment of Quality of Life, AQOL-8D questionnaire), and adverse events (AE). RESULTS Due to avoidance of one surgical step, the surgical technique was simplified. Mean WRS in SF was 11.1 ± 22.2% (range 0-55%) pre- and 77.2 ± 19.9% (range 30-95%) postoperatively; mean SF threshold (pure tone audiometry, PTA4) improved from 61.2 ± 14.3 dB HL (range 37.0-75.3 dB HL) to 31.9 ± 7.2 dB HL (range 22.8-45.0 dB HL); mean BC thresholds were constant at 16.7 ± 6.8 dB HL (range 6.3-27.5 dB HL) pre- and 14.2 ± 6.2 dB HL (range 5.8-23.8 dB HL) postoperatively. AQOL-8D mean utility score increased from 0.65 ± 0.18 preoperatively to 0.82 ± 0.17 postoperatively. No device-related adverse events occurred. CONCLUSION Implant fixation by means of self-drilling screws was safe and effective in all nine patients. There was significant audiological benefit 12 months after implantation.
Collapse
Affiliation(s)
- Assen Koitschev
- Klinik für Hals‑, Nasen‑, Ohrenkrankheiten , Plastische Operationen, Klinikum Stuttgart - Olgahospital, Kriegsbergstr. 62, 70174, Stuttgart, Deutschland.
| | - Marcus Neudert
- Klinik und Poliklinik für HNO, Universitätsklinikum Carl Gustav Carus an der TU Dresden, Dresden, Deutschland
| | - Thomas Lenarz
- Klinik für Hals-Nasen-Ohrenheilkunde, Medizinische Hochschule Hannover, Hannover, Deutschland
| |
Collapse
|
2
|
Lein A, Baumgartner WD, Riss D, Gstöttner W, Landegger LD, Liu DT, Thurner T, Vyskocil E, Brkic FF. Early Results With the New Active Bone-Conduction Hearing Implant: A Systematic Review and Meta-Analysis. Otolaryngol Head Neck Surg 2024; 170:1630-1647. [PMID: 38529662 DOI: 10.1002/ohn.728] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2023] [Revised: 12/12/2023] [Accepted: 02/02/2024] [Indexed: 03/27/2024]
Abstract
OBJECTIVE The bone conduction implant (BCI) 602 is a new transcutaneous BCI with smaller dimensions. However, limited patient numbers restrict the statistical power and generalizability of the current studies. The present systematic review and meta-analysis summarize early audiological and medical outcomes of adult and pediatric patients implanted with the BCI 602 due to mixed or conductive hearing loss. DATA SOURCE Following the Preferred Reporting items for Systematic Reviews and Meta-analyses guidelines, 108 studies were reviewed, and 6 (5.6%) were included in the meta-analysis. REVIEW METHOD The data on study and patient characteristics, surgical outcomes, and audiological test results were extracted from each article. Meta-analysis employed the fixed-effect and random-effects models to analyze the mean differences (MDs) between pre- and postoperative performances. RESULTS In total, 116 patients were evaluated, including 64 (55%) adult and 52 (45%) pediatric patients. No intraoperative adverse events were reported, while postoperative complications were reported in 2 (3.1%) adult and 2 (3.8%) pediatric patients. Studies consistently showed significant improvements in audiological outcomes, quality of life, and sound localization in the aided condition. In the meta-analysis, we observed a significant difference in the unaided compared to the aided condition in sound field thresholds (n = 112; MD, -27.05 dB; P < 0.01), signal-to-noise ratio (n = 96; MD, -6.35 dB; P < 0.01), and word recognition scores (n = 96; MD, 68.89%; P < 0.01). CONCLUSION The implantation of the BCI 602 was associated with minimal surgical complications and excellent audiological outcomes for both the pediatric and the adult cohort. Therefore, our analysis indicates a high level of safety and reliability. Further research should focus on direct comparisons with other BCIs and long-term functional outcomes.
Collapse
Affiliation(s)
- Alexander Lein
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical University of Vienna, Vienna, Austria
| | - Wolf-Dieter Baumgartner
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical University of Vienna, Vienna, Austria
| | - Dominik Riss
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical University of Vienna, Vienna, Austria
| | - Wolfgang Gstöttner
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical University of Vienna, Vienna, Austria
| | - Lukas D Landegger
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical University of Vienna, Vienna, Austria
| | - David T Liu
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical University of Vienna, Vienna, Austria
| | - Thomas Thurner
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical University of Vienna, Vienna, Austria
| | - Erich Vyskocil
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical University of Vienna, Vienna, Austria
| | - Faris F Brkic
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
3
|
Di Gregorio MF, Der C, Bravo-Torres S, Zernotti ME. Active Bone Conduction Implant and Adhesive Bone Conduction Device: A Comparison of Audiological Performance and Subjective Satisfaction. Int Arch Otorhinolaryngol 2024; 28:e332-e338. [PMID: 38618604 PMCID: PMC11008936 DOI: 10.1055/s-0043-1777416] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Accepted: 11/03/2023] [Indexed: 04/16/2024] Open
Abstract
Introduction Atresia of the external auditory canal affects 1 in every 10 thousand to 20 thousand live births, with a much higher prevalence in Latin America, at 5 to 21 out of every 10 thousand newborns. The treatment involves esthetic and functional aspects. Regarding the functional treatment, there are surgical and nonsurgical alternatives like spectacle frames and rigid and softband systems. Active transcutaneous bone conduction implants (BCIs) achieve good sound transmission and directly stimulate the bone. Objective To assess the audiological performance and subjective satisfaction of children implanted with an active transcutaneous BCI for more than one year and to compare the outcomes with a nonsurgical adhesive bone conduction device (aBCD) in the same users. Methods The present is a prospective, multicentric study. The audiological performance was evaluated at 1, 6, and 12 months postactivation, and after a 1-month trial with the nonsurgical device. Results Ten patients completed all tests. The 4-frequency pure-tone average (4PTA) in the unaided condition was of 65 dB HL, which improved significantly to 20 dB HL after using the BCI for 12 months. The speech recognition in quiet in the unaided condition was of 33% on average, which improved significantly, to 99% with the BCI, and to 91% with the aBCD. Conclusion The aBCD demonstrated sufficient hearing improvement and subjective satisfaction; thus, it is a good solution for hearing rehabilitation if surgery is not desired or not possible. If surgery is an option, the BCI is the superior device in terms of hearing outcomes, particularly background noise and subjective satisfaction.
Collapse
Affiliation(s)
| | - Carolina Der
- Department of Otorhinolaryngology, Hospital Dr. Luis Calvo Mackenna, Providencia, Santiago, Chile
| | - Sofia Bravo-Torres
- Department of Audiology, Hospital Dr. Luis Calvo Mackenna, Providencia, Santiago, Chile
| | - Mario Emilio Zernotti
- Department of ENT, Sanatorio Allende, Nueva Córdoba, Córdoba, Argentina
- Speech Therapy School, Faculty of Medical Sciences, Universidad Nacional de Córdoba, Córdoba, Argentina
| |
Collapse
|
4
|
Gutierrez JA, Shannon CM, Nguyen SA, Meyer TA, Lambert PR. Comparison of Quality of Life Outcomes for Percutaneous Versus Transcutaneous Implantable Hearing Devices: A Systematic Review and Meta-analysis. Otol Neurotol 2024; 45:e129-e136. [PMID: 38270194 DOI: 10.1097/mao.0000000000004111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2024]
Abstract
OBJECTIVE To compare quality of life (QOL) outcomes of percutaneous and transcutaneous bone conduction devices (pBCD and tBCD, respectively). DATABASES REVIEWED Pubmed, Scopus, CINAHL. METHODS A systematic review was performed searching for English language articles from inception to March 15, 2023. Studies reporting QOL outcomes measured using a validated tool following implantation of either pBCDs or tBCDs were considered for inclusion. QOL outcomes included scores for Glasgow Benefit Inventory, Glasgow Children's Benefit Inventory, Abbreviated Profile of Hearing Aid Benefit, and the Speech, Spatial, and Qualities of Hearing Scale. A meta-analysis of continuous measures was performed. RESULTS A total of 52 articles with 1,469 patients were included. Six hundred eighty-nine patients were implanted with pBCDs, and the remaining 780 were implanted with tBCDs. Average Glasgow Benefit Inventory scores for the tBCD group (33.0, 95% confidence interval [22.7-43.3]) were significantly higher than the pBCD group (30.9 [25.2-36.6]) (Δ2.1 [1.4-2.8], p < 0.0001). Mean Glasgow Children's Benefit Inventory scores (Δ3.9 [2.0-5.8], p = 0.0001) and mean gain in Abbreviated Profile of Hearing Aid Benefit scores (Δ5.6 [4.8-6.4], p < 0.0001) were significantly higher among patients implanted with tBCDs than those implanted with pBCDs. Patients implanted with tBCDs also had significantly higher gains on the Speech (Δ1.1 [0.9-1.3], p < 0.0001), Spatial (Δ0.8 [0.7-0.9], p < 0.0001), and Qualities of Hearing (Δ1.2 [1.1-1.3], p < 0.0001) portions of the Speech, Spatial, and Qualities of Hearing Scale than those implanted with pBCDs. CONCLUSIONS Patients implanted with transcutaneous devices had better QOL outcomes than those implanted with percutaneous devices.
Collapse
Affiliation(s)
- Jorge A Gutierrez
- Department of Otolaryngology-Head and Neck Surgery, Medical University of South Carolina, Charleston, SC
| | | | | | | | | |
Collapse
|
5
|
Brkic FF, Baumgartner WD, Schlott M, Liu DT, Thurner T, Riss D, Gstöttner W, Vyskocil E. Experience With the New Active Transcutaneous Bone-Conduction Implant With Smaller Dimensions. Otolaryngol Head Neck Surg 2023; 169:615-621. [PMID: 36939484 DOI: 10.1002/ohn.269] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Revised: 12/13/2022] [Accepted: 12/29/2022] [Indexed: 01/30/2023]
Abstract
OBJECTIVE Recently, the Bonebridge 602 implant was introduced. Its smaller dimensions facilitate implantation even in surgically demanding cases. However, in extreme anatomical conditions, implant lifts are still required. We intended to report on the medical and audiological outcomes of all patients implanted with the implant with a secondary focus on the safety, efficacy, and feasibility of the use of 1-mm lifts. STUDY DESIGN Retrospective cohort study. SETTING Tertiary academic center. METHODS We retrospectively analyzed all patients implanted with the Bonebridge 602. Patient demographics and surgically-specific data were collected from the medical charts. Furthermore, audiological results were assessed. Outcomes were compared between implantations with versus without lifts. RESULTS Twenty-one devices were implanted during the study period. Satisfactory audiological results were observed, while no intra- or postoperative adverse events occurred. The majority of patients were daily users at the end of the observation period (n = 20/21, 95.2%), and one patient (n = 1/21, 4.8%) was a nonuser after 6 months of use because of subjective dissatisfaction. Due to anatomical considerations, 1-mm lifts were used in 4 implantations (19.0%). The application of lifts did not result in prolonged surgical times, complications, or shorter time of use, nor did it negatively affect audiometric results. CONCLUSION Implantations with the new and smaller Bonebridge were associated with gratifying medical and audiological outcomes. Still, in extreme anatomical conditions, 1-mm lifts are necessary. Nonetheless, surgical placement with the help of lifts seems safe, effective, and feasible, and is a viable option in cases with challenging anatomies due to previous surgeries or anomalies.
Collapse
Affiliation(s)
- Faris F Brkic
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical University of Vienna, Vienna, Austria
| | - Wolf-Dieter Baumgartner
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical University of Vienna, Vienna, Austria
| | - Melina Schlott
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical University of Vienna, Vienna, Austria
| | - David T Liu
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical University of Vienna, Vienna, Austria
| | - Thomas Thurner
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical University of Vienna, Vienna, Austria
| | - Dominik Riss
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical University of Vienna, Vienna, Austria
| | - Wolfgang Gstöttner
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical University of Vienna, Vienna, Austria
| | - Erich Vyskocil
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
6
|
Koitschev A, Neudert M, Lenarz T. A bone conduction implant using self-drilling screws : Self-drilling screws as a new fixation method of an active transcutaneous bone conduction hearing implant. HNO 2023; 71:61-66. [PMID: 37322168 DOI: 10.1007/s00106-023-01295-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/06/2023] [Indexed: 06/17/2023]
Abstract
BACKGROUND The active transcutaneous bone conduction implant (tBCI; BONEBRIDGE™ BCI 601; MED-EL, Innsbruck, Austria) is fixed to the skull with two self-tapping screws in predrilled screw channels. The aim of this prospective study was to evaluate the safety and effectiveness of fixation with self-drilling screws instead of the self-tapping screws, in order to simplify the surgical procedure. MATERIALS AND METHODS Nine patients (mean age 37 ± 16 years, range 14-57 years) were examined pre- and 12 months postoperatively for word recognition scores (WRS) at 65 dB SPL, sound-field (SF) thresholds, bone conduction thresholds (BC), health-related quality of life (Assessment of Quality of Life, AQOL-8D questionnaire), and adverse events (AE). RESULTS Due to avoidance of one surgical step, the surgical technique was simplified. Mean WRS in SF was 11.1 ± 22.2% (range 0-55%) pre- and 77.2 ± 19.9% (range 30-95%) postoperatively; mean SF threshold (pure tone audiometry, PTA4) improved from 61.2 ± 14.3 dB HL (range 37.0-75.3 dB HL) to 31.9 ± 7.2 dB HL (range 22.8-45.0 dB HL); mean BC thresholds were constant at 16.7 ± 6.8 dB HL (range 6.3-27.5 dB HL) pre- and 14.2 ± 6.2 dB HL (range 5.8-23.8 dB HL) postoperatively. AQOL-8D mean utility score increased from 0.65 ± 0.18 preoperatively to 0.82 ± 0.17 postoperatively. No device-related adverse events occurred. CONCLUSION Implant fixation by means of self-drilling screws was safe and effective in all nine patients. There was significant audiological benefit 12 months after implantation.
Collapse
Affiliation(s)
- Assen Koitschev
- Klinik für Hals‑, Nasen‑, Ohrenkrankheiten, Plastische Operationen, Klinikum Stuttgart-Olgahospital, Kriegsbergstraße 62, 70174, Stuttgart, Germany.
| | - Marcus Neudert
- Klinik für Hals‑, Nasen‑, Ohrenkrankheiten, Plastische Operationen, Universitätsklinikum Carl Gustav Carus an der TU Dresden, Dresden, Germany
| | - Thomas Lenarz
- Klinik für Hals‑, Nasen‑, Ohrenkrankheiten, Plastische Operationen, Medizinische Hochschule Hannover, Hannover, Germany
| |
Collapse
|