Ramirez NC, Collins SM. A new determination of the 68Ga half-life and evaluation of literature data. Appl Radiat Isot 2024; 203:111103. [PMID: 37977103 DOI: 10.1016/j.apradiso.2023.111103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 10/30/2023] [Accepted: 11/01/2023] [Indexed: 11/19/2023]
Abstract
Inconsistencies within the 68Ga half-life dataset have been repeatedly identified in nuclear decay data evaluations performed over the past decade. In this paper, a half-life has been determined using ionisation chambers measurements and HPGe gamma-ray spectrometry (T1/2 = 67.783(27) min). The current literature has been reviewed and possible causes of discrepancy have been identified, such as neglected contaminant effects, robustness of analysis, and underestimation of systematic effects. This could lead to a significant improvement of the half-life in future evaluations.
Collapse
Affiliation(s)
- N C Ramirez
- National Physical Laboratory, Hampton Road, Teddington, Middlesex, UK.
| | - S M Collins
- National Physical Laboratory, Hampton Road, Teddington, Middlesex, UK
| |
Collapse
|
2
|
Nichols AL. Status of the decay data for medical radionuclides: existing and potential diagnostic γ emitters, diagnostic β + emitters and therapeutic radioisotopes. RADIOCHIM ACTA 2022. [DOI: 10.1515/ract-2022-0004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Abstract
Recommended half-lives and specific well-defined emission energies and absolute emission probabilities are important input parameters that should be well-defined to assist in ensuring the diagnostic and therapeutic efficacy of individual radionuclides when applied in the field of nuclear medicine. Bearing in mind the nature of these requirements, approximately one hundred radionuclides have been considered and re-assessed as to whether their decay data are either adequately quantified, or require further in-depth measurements to improve their existing status and merit full re-evaluations of their decay schemes. The primary aim of such a review is to provide sufficient information on the existing and future requirements for such atomic and nuclear data.
Collapse
Affiliation(s)
- Alan L. Nichols
- Department of Physics , University of Surrey , Guildford , GU2 7XH , UK
- Manipal Academy of Higher Education, Manipal, Karnataka 576104 , India
| |
Collapse
|
3
|
Sahagia M, Grigorescu EL, Luca A, Wätjen AC, Ivan C, Antohe A, Ioan MR. 60 years of absolute standardization of radionuclides by coincidence counting methods in the Romanian metrology laboratory. Appl Radiat Isot 2021; 174:109707. [PMID: 33975228 DOI: 10.1016/j.apradiso.2021.109707] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2020] [Revised: 03/24/2021] [Accepted: 03/25/2021] [Indexed: 11/30/2022]
Abstract
This review paper presents the contribution of the Radionuclide Metrology Laboratory (RML) to the development and practical application of the coincidence counting methods. It is also intended to pay tribute to Dr. Enric Leon Grigorescu, the founder of our school of radionuclide metrology. A synthetic treatment of the method, applied to some classes of radionuclides with their common and particular aspects in standardization, is presented: pioneering calculation of instrumental corrections, specific method corrections applied for various types of decay schemes in the variant of efficiency extrapolation, results obtained in international comparisons.
Collapse
Affiliation(s)
- Maria Sahagia
- Horia Hulubei National Institute for R&D in Physics and Nuclear Engineering, IFIN-HH, Bucharest. 30 Reactorului St. Măgurele, jud. Ilfov, POB MG-6, RO 0-77125, Romania.
| | - Enric Leon Grigorescu
- Horia Hulubei National Institute for R&D in Physics and Nuclear Engineering, IFIN-HH, Bucharest. 30 Reactorului St. Măgurele, jud. Ilfov, POB MG-6, RO 0-77125, Romania
| | - Aurelian Luca
- Horia Hulubei National Institute for R&D in Physics and Nuclear Engineering, IFIN-HH, Bucharest. 30 Reactorului St. Măgurele, jud. Ilfov, POB MG-6, RO 0-77125, Romania
| | - Anamaria Cristina Wätjen
- Horia Hulubei National Institute for R&D in Physics and Nuclear Engineering, IFIN-HH, Bucharest. 30 Reactorului St. Măgurele, jud. Ilfov, POB MG-6, RO 0-77125, Romania
| | - Constantin Ivan
- Horia Hulubei National Institute for R&D in Physics and Nuclear Engineering, IFIN-HH, Bucharest. 30 Reactorului St. Măgurele, jud. Ilfov, POB MG-6, RO 0-77125, Romania
| | - Andrei Antohe
- Horia Hulubei National Institute for R&D in Physics and Nuclear Engineering, IFIN-HH, Bucharest. 30 Reactorului St. Măgurele, jud. Ilfov, POB MG-6, RO 0-77125, Romania
| | - Mihail Răzvan Ioan
- Horia Hulubei National Institute for R&D in Physics and Nuclear Engineering, IFIN-HH, Bucharest. 30 Reactorului St. Măgurele, jud. Ilfov, POB MG-6, RO 0-77125, Romania
| |
Collapse
|
4
|
Kuzmenko NK. Updated decay data evaluation for 68Ga. Appl Radiat Isot 2019; 152:188-192. [DOI: 10.1016/j.apradiso.2019.07.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2019] [Revised: 04/09/2019] [Accepted: 07/05/2019] [Indexed: 11/29/2022]
|
5
|
Yamazaki IM, Koskinas MF, Moreira DS, Takeda MN, Dias MS. Disintegration rate and gamma-ray emission probability per decay measurement of Cu-64. Appl Radiat Isot 2018; 134:312-315. [PMID: 28927836 DOI: 10.1016/j.apradiso.2017.09.007] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2017] [Revised: 08/03/2017] [Accepted: 09/05/2017] [Indexed: 11/15/2022]
Abstract
The procedure followed by the Nuclear Metrology Laboratory (LMN) at the IPEN for the standardization of activity of 64Cu is described. The measurement was carried out in a 4π (PC) β-γ coincidence system. The activity per unit mass of the solution was determined by the extrapolation technique. The events were registered using a Time to Amplitude Converter (TAC) associated with a Multi-channel Analyzer. The gamma-ray emission probability per decay of the 1345.7keV transition of 64Cu determined with a calibrated REGe gamma-ray spectrometer was (0.472 ± 0.010) %, in agreement with the literature.
Collapse
Affiliation(s)
- I M Yamazaki
- Instituto de Pesquisas Energéticas e Nucleares, IPEN-CNEN/SP, Av. Prof. Lineu Prestes 2242, 05508-000 São Paulo, SP, Brazil
| | - M F Koskinas
- Instituto de Pesquisas Energéticas e Nucleares, IPEN-CNEN/SP, Av. Prof. Lineu Prestes 2242, 05508-000 São Paulo, SP, Brazil.
| | - D S Moreira
- Instituto de Pesquisas Energéticas e Nucleares, IPEN-CNEN/SP, Av. Prof. Lineu Prestes 2242, 05508-000 São Paulo, SP, Brazil
| | - M N Takeda
- Instituto de Pesquisas Energéticas e Nucleares, IPEN-CNEN/SP, Av. Prof. Lineu Prestes 2242, 05508-000 São Paulo, SP, Brazil
| | - M S Dias
- Instituto de Pesquisas Energéticas e Nucleares, IPEN-CNEN/SP, Av. Prof. Lineu Prestes 2242, 05508-000 São Paulo, SP, Brazil
| |
Collapse
|
6
|
Pibida L, Zimmerman B, Bergeron DE, Fitzgerald R, Cessna JT, King L. Determination of photon emission probability for the main gamma ray and half-life measurements of 64Cu. Appl Radiat Isot 2017; 129:6-12. [PMID: 28783614 PMCID: PMC6290464 DOI: 10.1016/j.apradiso.2017.07.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2017] [Revised: 06/30/2017] [Accepted: 07/02/2017] [Indexed: 11/19/2022]
Abstract
The National Institute of Standards and Technology (NIST) performed new standardization measurements for 64Cu. As part of this work the photon emission probability for the main gamma-ray line and the half-life were determined using several high-purity germanium (HPGe) detectors. Half-life determinations were also carried out with a NaI(Tl) well counter and two pressurized ionization chambers.
Collapse
Affiliation(s)
- L Pibida
- National Institute of Standards and Technology, 100 Bureau Dr, MS 8462, Gaithersburg, MD, 20899-8462, USA.
| | - B Zimmerman
- National Institute of Standards and Technology, 100 Bureau Dr, MS 8462, Gaithersburg, MD, 20899-8462, USA
| | - D E Bergeron
- National Institute of Standards and Technology, 100 Bureau Dr, MS 8462, Gaithersburg, MD, 20899-8462, USA
| | - R Fitzgerald
- National Institute of Standards and Technology, 100 Bureau Dr, MS 8462, Gaithersburg, MD, 20899-8462, USA
| | - J T Cessna
- National Institute of Standards and Technology, 100 Bureau Dr, MS 8462, Gaithersburg, MD, 20899-8462, USA
| | - L King
- National Institute of Standards and Technology, 100 Bureau Dr, MS 8462, Gaithersburg, MD, 20899-8462, USA
| |
Collapse
|
7
|
Zimmerman BE, Bergeron DE, Edgerton JP. Assessing the absolute quantitative accuracy of Positron Emission Tomography for Cu-64 using traceable calibrated phantoms. Appl Radiat Isot 2017; 134:68-73. [PMID: 28974328 DOI: 10.1016/j.apradiso.2017.09.016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2017] [Revised: 06/07/2017] [Accepted: 09/11/2017] [Indexed: 11/18/2022]
Abstract
Using uniform cylindrical phantoms containing calibrated solutions of 18F and 64Cu, we evaluated for the first time the accuracy with which the activity concentration of 64Cu can be quantified on an absolute basis using Positron Emission Tomography (with X-ray Computed Tomography, PET-CT). The scanner was first calibrated for 18F using the manufacturer's calibration protocol and a phantom with an activity concentration value traceable to the U.S. National standard. By using a similarly calibrated 18F solution phantom, we were able to determine a correction factor that can be applied to the 64Cu imaging data that gave a result that is consistent with 100% recovery with a combined standard uncertainty of 2%. We also demonstrate how a calibrated, solid phantom containing 68Ge as a long-lived 18F surrogate can be used to monitor and transfer the correction factor to other studies.
Collapse
Affiliation(s)
- B E Zimmerman
- Physical Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, MD 20899-8462, USA.
| | - D E Bergeron
- Physical Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, MD 20899-8462, USA
| | - J P Edgerton
- Department of Physics and Astronomy, Appalachian State University, Boone, NC 28608, USA
| |
Collapse
|
8
|
Standardisation of a 68(Ge+Ga) solution within the CCRI(II)-K2.Ge-68 key comparison. J Radioanal Nucl Chem 2016. [DOI: 10.1007/s10967-016-4981-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
9
|
|
10
|
Luca A, Sahagia M, Ioan MR, Antohe A, Savu BL. Experimental determination of some nuclear decay data in the decays of 177 Lu, 186 Re and 124 I. Appl Radiat Isot 2016; 109:146-150. [DOI: 10.1016/j.apradiso.2015.11.072] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2015] [Accepted: 11/24/2015] [Indexed: 10/22/2022]
|
11
|
Standardization of 18F and its use for the Romanian PET metrological traceability chain assurance. Appl Radiat Isot 2014; 87:14-8. [DOI: 10.1016/j.apradiso.2013.11.047] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2013] [Accepted: 11/18/2013] [Indexed: 11/19/2022]
|
12
|
Koskinas MF, Lacerda FW, Matos IT, Nascimento TS, Yamazaki IM, Takeda MN, Dias MS. Determination of gamma-ray emission probabilities per decay of Ga-68. Appl Radiat Isot 2014; 87:118-21. [DOI: 10.1016/j.apradiso.2013.11.003] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2013] [Accepted: 11/03/2013] [Indexed: 11/28/2022]
|
13
|
García-Toraño E, Peyrés Medina V, Romero E, Roteta M. Measurement of the half-life of ⁶⁸Ga. Appl Radiat Isot 2013; 87:122-5. [PMID: 24342557 DOI: 10.1016/j.apradiso.2013.11.082] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2013] [Accepted: 11/17/2013] [Indexed: 11/28/2022]
Abstract
The half-life of the positron-emitter (68)Ga has been measured by following the decay rate with two systems based on ionization chamber and Ge detectors. The decay rate was measured for periods of time up to 10 half-lives. The combination of the 6 results obtained with both systems gives a value of T1/2=67.845(18) min, in good agreement with recommended data and with an uncertainty lower than any other previously reported value.
Collapse
Affiliation(s)
- Eduardo García-Toraño
- Laboratorio de Metrología de Radiaciones Ionizantes, CIEMAT, Avenida Complutense 40, Madrid 28040, Spain.
| | - Virginia Peyrés Medina
- Laboratorio de Metrología de Radiaciones Ionizantes, CIEMAT, Avenida Complutense 40, Madrid 28040, Spain
| | - Eduardo Romero
- Unidad de Aplicaciones Biomédicas y Farmacocinética, CIEMAT, Avenida Complutense 40, Madrid 28040, Spain
| | - Miguel Roteta
- Laboratorio de Metrología de Radiaciones Ionizantes, CIEMAT, Avenida Complutense 40, Madrid 28040, Spain
| |
Collapse
|
14
|
Sahagia M, Luca A, Antohe A, Ivan C. Standardization of 64Cu and 68Ga by the 4π(PC)β-γ coincidence method and calibration of the ionization chamber. Appl Radiat Isot 2012; 70:2025-30. [DOI: 10.1016/j.apradiso.2012.02.043] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2011] [Accepted: 02/19/2012] [Indexed: 11/24/2022]
|