Nedjadi Y, Juget F, Durán MT, Desorgher L, Bochud F, Bailat C. Activity standardisation of 177Lu. Appl Radiat Isot 2023; 200:110986. [PMID: 37597267 DOI: 10.1016/j.apradiso.2023.110986] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 08/08/2023] [Accepted: 08/14/2023] [Indexed: 08/21/2023]
Abstract
177Lu decays through low-energy β-- and γ-emissions in addition to conversion and Auger electrons. To support the use of this radiopharmaceutical in Switzerland, a 177Lu solution was standardised using the β-γ coincidence technique, as well as the TDCR method. The solution had no 177mLu impurity. Primary coincidence measurements, with plastic scintillators for beta detection, were carried out using both analogue and digital electronics. TDCR measurements using only defocusing were also made. Monte Carlo calculations were used to compute the detection efficiency. The coincidence measurements with both analogue and digital electronics are compatible within one standard uncertainty, but they are lower than (and discrepant with) the TDCR measurements. An ampoule of this solution was submitted to the BIPM as a contribution to the Système International de Référence.
Collapse
|
2
|
Sekikawa Y, Funada K, Akamatsu G, Himuro K, Takahashi A, Baba S, Sasaki M. Monte Carlo simulation of the acquisition conditions for 177Lu molecular imaging of hepatic tumors. Ann Nucl Med 2021; 35:823-833. [PMID: 34057655 DOI: 10.1007/s12149-021-01620-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2020] [Accepted: 04/21/2021] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To examine the impact of acquisition time on Lutetium-177 (177Lu) single-photon emission computed tomography (SPECT) images using Monte Carlo simulation. METHODS A gamma camera simulation based on the Monte Carlo method was performed to produce SPECT images. The phantom was modeled on a NEMA IEC BODY phantom including six spheres as tumors. After the administration of 7.4 GBq of 177Lu, radioactivity concentrations of the tumor/liver at 6, 24, and 72 h after administration were set to 1.85/0.201, 2.12/0.156, and 1.95/0.117 MBq/mL, respectively. In addition, the radioactivity concentrations of the tumor at 72 h after administration varied by 1/2, 1/4, and 1/8 when comparison was made. Acquisition times examined were 1.2, 1.5, 2, 3, 6, and 12 min. To assess the impact of collimators, SPECT data acquired at 72 h after the administration using six collimators of low-energy high-resolution (LEHR), extended low-energy general-purpose (ELEGP), medium-energy, and general-purpose (MEGP-1, MEGP-2, and MEGP-3) and high-energy general-purpose (HEGP) were examined. After prefiltering using a Butterworth filter, projection images were reconstructed using ordered subset expectation maximization. The detected photons were classified into direct rays, scattered rays, penetrating rays, and characteristic X-rays from lead. The image quality was evaluated through visual assessment, and physical assessment of contrast recovery coefficient (CRC) and contrast-to-noise ratio (CNR). In this study, the CNR threshold for detectability was assumed to be 5.0. RESULTS To compare collimators, the highest sensitivity was observed with ELEGP, followed by LEHR and MEGP-1. The highest ratio of direct ray was also observed in ELEGP followed by MEGP-1. In comparison of the radioactivity concentration ratios of tumor/liver, CRC and CNR were significantly decreased with smaller radioactivity concentration ratios. This effect was greater with larger spheres. According to the visual assessment, the acquisition time of 6, 6, and 3 min or longer was required using ELEGP collimator at 6, 24, and 72 h after administration, respectively. Physical assessment based on CNR and CRC also suggested that 6, 6, and 3 min or longer acquisition time was necessary at 6, 24, and 72 h after administration. CONCLUSION 177Lu-SPECT images generated via the Monte Carlo simulation suggested that the recommended acquisition time was 6 min or longer at 6 and 24 h and 3 min or longer at 72 h after administration.
Collapse
Affiliation(s)
- Yuya Sekikawa
- Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan
- Department of Radiological Technology, Faculty of Fukuoka Medical Technology, Teikyo University, 6-22 Misakimachi, Omuta, Fukuoka, 836-8505, Japan
| | - Keita Funada
- Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan
| | - Go Akamatsu
- National Institutes for Quantum and Radiological Science and Technology (QST), 4-9-1 Anagawa, Inage-ku, Chiba, 263-8555, Japan
| | - Kazuhiko Himuro
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan
| | - Akihiko Takahashi
- Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
| | - Shingo Baba
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan
| | - Masayuki Sasaki
- Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan
| |
Collapse
|
5
|
Dryák P, Sochorová J, Šolc J, Auerbach P. Activity standardization, photon emission probabilities and half-life measurements of (177)Lu. Appl Radiat Isot 2015; 109:160-163. [PMID: 26653215 DOI: 10.1016/j.apradiso.2015.11.059] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2015] [Accepted: 11/23/2015] [Indexed: 11/27/2022]
Abstract
Activity standardization of (177)Lu and measurement of two nuclear parameters were done. Activity standardization of (177)Lu was done utilizing the 4πβ-γ coincidence method with a combined standard uncertainty of 0.28%. Emission probability of 112.95keV and 208.37keV was measured by calibrated spectrometer with HPGe detector. The efficiency was computed with MCNP code and validated using experimental points. Half-life was derived from prolonged measurement of peak area by three different spectrometer systems and also from measurement with ionization chamber.
Collapse
Affiliation(s)
- Pavel Dryák
- Czech Metrology Institute, Radiová 1, 102 00 Praha 10, Czech Republic.
| | - Jana Sochorová
- Czech Metrology Institute, Radiová 1, 102 00 Praha 10, Czech Republic
| | - Jaroslav Šolc
- Czech Metrology Institute, Radiová 1, 102 00 Praha 10, Czech Republic
| | - Pavel Auerbach
- Czech Metrology Institute, Radiová 1, 102 00 Praha 10, Czech Republic
| |
Collapse
|