Yechiel Y, Chicheportiche A, Keidar Z, Ben-Haim S. Prostate Cancer Radioligand Therapy: Beta-labeled Radiopharmaceuticals. PET Clin 2024; 19:389-399. [PMID: 38679550 DOI: 10.1016/j.cpet.2024.03.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/01/2024]
Abstract
Prostate cancer is the most common malignancy in men worldwide, with an estimated 174,650 new cases per year in the United States, and the second cancer-related cause of death, after lung cancer, with 31,620 deaths per year. While the 5 year survival rate for prostate cancer in patients without metastatic spread is nearly 100%, those with distant metastases have 5 year survival rates of approximately 30%. Initial diagnosis and assessment are based on PSA levels, Gleason score (derived from prostate biopsy), and advanced imaging modalities, including prostate MR imaging and PSMA-PET/computed tomography in patients with high-risk features.
Collapse
Affiliation(s)
- Yaniv Yechiel
- Department of Nuclear Medicine, Rambam Health Care Campus, Haifa, Israel.
| | | | - Zohar Keidar
- Department of Nuclear Medicine, Rambam Health Care Campus, Haifa, Israel; Technion - Israel Institute of Technology, Haifa, Israel
| | - Simona Ben-Haim
- Department of Biophysics and Nuclear Medicine, Hadassah Medical Organization, Jerusalem, Israel; Hebrew University of Jerusalem, Jerusalem, Israel; University College London, London, UK
| |
Collapse
|
2
|
Danieli R, Stella M, Leube J, Tran-Gia J, Marin C, Uribe CF, Vanderlinden B, Reynaert N, Flamen P, Levillain H. Quantitative 177Lu SPECT/CT imaging for personalized dosimetry using a ring-shaped CZT-based camera. EJNMMI Phys 2023; 10:64. [PMID: 37853247 PMCID: PMC10584798 DOI: 10.1186/s40658-023-00586-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Accepted: 10/12/2023] [Indexed: 10/20/2023] Open
Abstract
BACKGROUND Dosimetry after radiopharmaceutical therapy with 177Lu (177Lu-RPT) relies on quantitative SPECT/CT imaging, for which suitable reconstruction protocols are required. In this study, we characterized for the first time the quantitative performance of a ring-shaped CZT-based camera using two different reconstruction algorithms: an ordered subset expectation maximization (OSEM) and a block sequential regularized expectation maximization (BSREM) combined with noise reduction regularization. This study lays the foundations for the definition of a reconstruction protocol enabling accurate dosimetry for patients treated with 177Lu-RPT. METHODS A series of 177Lu-filled phantoms were acquired on a StarGuide™ (GE HealthCare), with energy and scatter windows centred at 208 (± 6%) keV and 185 (± 5%) keV, respectively. Images were reconstructed with the manufacturer implementations of OSEM (GE-OSEM) and BSREM (Q.Clear) algorithms, and various combinations of iterations and subsets. Additionally, the manufacturer-recommended Q.Clear-based reconstruction protocol was evaluated. Quantification accuracy, measured as the difference between the SPECT-based and the radionuclide calibrator-based activity, and noise were evaluated in a large cylinder. Recovery coefficients (RCs) and spatial resolution were assessed in a NEMA IEC phantom with sphere inserts. The reconstruction protocols considered suitable for clinical applications were tested on a cohort of patients treated with [177Lu]Lu-PSMA-I&T. RESULTS The accuracy of the activity from the cylinder, although affected by septal penetration, was < 10% for all reconstructions. Both algorithms featured improved spatial resolution and higher RCs with increasing updates at the cost of noise build-up, but Q.Clear outperformed GE-OSEM in reducing noise accumulation. When the reconstruction parameters were carefully selected, similar values for noise (~0.15), spatial resolution (~1 cm) and RCs were found, irrespective of the reconstruction algorithm. Analogue results were found in patients. CONCLUSIONS Accurate activity quantification is possible when imaging 177Lu with StarGuide™. However, the impact of septal penetration requires further investigations. GE-OSEM is a valid alternative to the recommended Q.Clear reconstruction algorithm, featuring comparable performances assessed on phantoms and patients.
Collapse
Affiliation(s)
- Rachele Danieli
- Department of Medical Physics, Institut Jules Bordet, Hôpital Universitaire de Bruxelles (H.U.B), Université Libre de Bruxelles (ULB), Brussels, Belgium.
- Radiophysics and MRI Physics Laboratory, Université Libre de Bruxelles (ULB), Brussels, Belgium.
| | - Martina Stella
- Radiophysics and MRI Physics Laboratory, Université Libre de Bruxelles (ULB), Brussels, Belgium
- GE HealthCare, Diegem, Belgium
| | - Julian Leube
- Department of Nuclear Medicine, University Hospital Würzburg, Würzburg, Germany
| | - Johannes Tran-Gia
- Department of Nuclear Medicine, University Hospital Würzburg, Würzburg, Germany
| | - Clementine Marin
- Department of Medical Physics, Institut Jules Bordet, Hôpital Universitaire de Bruxelles (H.U.B), Université Libre de Bruxelles (ULB), Brussels, Belgium
| | | | - Bruno Vanderlinden
- Department of Medical Physics, Institut Jules Bordet, Hôpital Universitaire de Bruxelles (H.U.B), Université Libre de Bruxelles (ULB), Brussels, Belgium
- Radiophysics and MRI Physics Laboratory, Université Libre de Bruxelles (ULB), Brussels, Belgium
| | - Nick Reynaert
- Department of Medical Physics, Institut Jules Bordet, Hôpital Universitaire de Bruxelles (H.U.B), Université Libre de Bruxelles (ULB), Brussels, Belgium
- Radiophysics and MRI Physics Laboratory, Université Libre de Bruxelles (ULB), Brussels, Belgium
| | - Patrick Flamen
- Department of Nuclear Medicine, Institut Jules Bordet, Hôpital Universitaire de Bruxelles (H.U.B), Université Libre de Bruxelles (ULB), Brussels, Belgium
| | - Hugo Levillain
- Department of Medical Physics, Institut Jules Bordet, Hôpital Universitaire de Bruxelles (H.U.B), Université Libre de Bruxelles (ULB), Brussels, Belgium
- Radiophysics and MRI Physics Laboratory, Université Libre de Bruxelles (ULB), Brussels, Belgium
| |
Collapse
|
3
|
Kayal G, Clayton N, Vergara-Gil A, Struelens L, Bardiès M. Proof-of-concept of DosiTest: A virtual multicentric clinical trial for assessing uncertainties in molecular radiotherapy dosimetry. Phys Med 2022; 97:25-35. [PMID: 35339863 DOI: 10.1016/j.ejmp.2022.03.011] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Revised: 01/19/2022] [Accepted: 03/14/2022] [Indexed: 11/16/2022] Open
Abstract
Clinical dosimetry in molecular radiotherapy (MRT) is a multi-step procedure, prone to uncertainties at every stage of the dosimetric workflow. These are difficult to assess, especially as some are complex or even impossible to measure experimentally. The DosiTest project was initiated to assess the variability associated with clinical dosimetry, by setting up a 'virtual' multicentric clinical dosimetry trial based on Monte Carlo (MC) modelling. A reference patient model with a realistic geometry and activity input for a specific tracer is considered. Reference absorbed dose rate distribution maps are generated at various time-points from MC modelling, combining precise information on density and activity distributions (voxel wise). Then, centre-specific calibration and patient SPECT/CT datasets are modelled, on which the clinical centres can perform clinical (i.e. image-based) dosimetry. The results of this dosimetric analysis can be benchmarked against the reference dosimetry to assess the variability induced by implementing different clinical dosimetry approaches. The feasibility of DosiTest is presented here for a clinical situation of therapeutic administration of 177Lu-DOTATATE (Lutathera®) peptide receptor radionuclide therapy (PRRT). From a real patient dataset composed of 5 SPECT/CT images and associated calibrations, we generated the reference absorbed dose rate images with GATE. Then, simulated SPECT/CT image generation based on GATE was performed, both for a calibration phantom and virtual patient images. Based on this simulated dataset, image-based dosimetry could be performed, and compared with reference dosimetry. The good agreement, between real and simulated images, and between reference and image-based dosimetry established the proof of concept of DosiTest.
Collapse
Affiliation(s)
- G Kayal
- CRCT, UMR 1037, INSERM, Université Toulouse III Paul Sabatier, Toulouse, France; SCK CEN, Belgian Nuclear Research Centre, Boeretang 200, Mol 2400, Belgium.
| | - N Clayton
- CRCT, UMR 1037, INSERM, Université Toulouse III Paul Sabatier, Toulouse, France
| | - A Vergara-Gil
- CRCT, UMR 1037, INSERM, Université Toulouse III Paul Sabatier, Toulouse, France
| | - L Struelens
- SCK CEN, Belgian Nuclear Research Centre, Boeretang 200, Mol 2400, Belgium
| | - M Bardiès
- ICM, Département de Médecine Nucléaire, Montpellier, France; IRCM, UMR 1194 INSERM, Université de Montpellier and ICM, Montpellier, France
| |
Collapse
|
4
|
Morphis M, van Staden JA, du Raan H, Ljungberg M. Evaluation of Iodine-123 and Iodine-131 SPECT activity quantification: a Monte Carlo study. EJNMMI Phys 2021; 8:61. [PMID: 34410539 PMCID: PMC8377107 DOI: 10.1186/s40658-021-00407-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Accepted: 08/10/2021] [Indexed: 01/18/2023] Open
Abstract
Purpose The quantitative accuracy of Nuclear Medicine images, acquired for both planar and SPECT studies, is influenced by the isotope-collimator combination as well as image corrections incorporated in the iterative reconstruction process. These factors can be investigated and optimised using Monte Carlo simulations. This study aimed to evaluate SPECT quantification accuracy for 123I with both the low-energy high resolution (LEHR) and medium-energy (ME) collimators and 131I with the high-energy (HE) collimator. Methods Simulated SPECT projection images were reconstructed using the OS-EM iterative algorithm, which was optimised for the number of updates, with appropriate corrections for scatter, attenuation and collimator detector response (CDR), including septal scatter and penetration compensation. An appropriate calibration factor (CF) was determined from four different source geometries (activity-filled: water-filled cylindrical phantom, sphere in water-filled (cold) cylindrical phantom, sphere in air and point-like source), investigated with different volume of interest (VOI) diameters. Recovery curves were constructed from recovery coefficients to correct for partial volume effects (PVEs). The quantitative method was evaluated for spheres in voxel-based digital cylindrical and patient phantoms. Results The optimal number of OS-EM updates was 60 for all isotope-collimator combinations. The CFpoint with a VOI diameter equal to the physical size plus a 3.0-cm margin was selected, for all isotope-collimator geometries. The spheres’ quantification errors in the voxel-based digital cylindrical and patient phantoms were less than 3.2% and 5.4%, respectively, for all isotope-collimator combinations. Conclusion The study showed that quantification errors of less than 6.0% could be attained, for all isotope-collimator combinations, if corrections for; scatter, attenuation, CDR (including septal scatter and penetration) and PVEs are performed. 123I LEHR and 123I ME quantification accuracies compared well when appropriate corrections for septal scatter and penetration were applied. This can be useful in departments that perform 123I studies and may not have access to ME collimators.
Collapse
Affiliation(s)
- Michaella Morphis
- Department of Medical Physics, Faculty of Health Sciences, University of the Free State, PO Box 339, Bloemfontein, 9300, South Africa.
| | - Johan A van Staden
- Department of Medical Physics, Faculty of Health Sciences, University of the Free State, PO Box 339, Bloemfontein, 9300, South Africa
| | - Hanlie du Raan
- Department of Medical Physics, Faculty of Health Sciences, University of the Free State, PO Box 339, Bloemfontein, 9300, South Africa
| | | |
Collapse
|
5
|
Sekikawa Y, Funada K, Akamatsu G, Himuro K, Takahashi A, Baba S, Sasaki M. Monte Carlo simulation of the acquisition conditions for 177Lu molecular imaging of hepatic tumors. Ann Nucl Med 2021; 35:823-833. [PMID: 34057655 DOI: 10.1007/s12149-021-01620-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2020] [Accepted: 04/21/2021] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To examine the impact of acquisition time on Lutetium-177 (177Lu) single-photon emission computed tomography (SPECT) images using Monte Carlo simulation. METHODS A gamma camera simulation based on the Monte Carlo method was performed to produce SPECT images. The phantom was modeled on a NEMA IEC BODY phantom including six spheres as tumors. After the administration of 7.4 GBq of 177Lu, radioactivity concentrations of the tumor/liver at 6, 24, and 72 h after administration were set to 1.85/0.201, 2.12/0.156, and 1.95/0.117 MBq/mL, respectively. In addition, the radioactivity concentrations of the tumor at 72 h after administration varied by 1/2, 1/4, and 1/8 when comparison was made. Acquisition times examined were 1.2, 1.5, 2, 3, 6, and 12 min. To assess the impact of collimators, SPECT data acquired at 72 h after the administration using six collimators of low-energy high-resolution (LEHR), extended low-energy general-purpose (ELEGP), medium-energy, and general-purpose (MEGP-1, MEGP-2, and MEGP-3) and high-energy general-purpose (HEGP) were examined. After prefiltering using a Butterworth filter, projection images were reconstructed using ordered subset expectation maximization. The detected photons were classified into direct rays, scattered rays, penetrating rays, and characteristic X-rays from lead. The image quality was evaluated through visual assessment, and physical assessment of contrast recovery coefficient (CRC) and contrast-to-noise ratio (CNR). In this study, the CNR threshold for detectability was assumed to be 5.0. RESULTS To compare collimators, the highest sensitivity was observed with ELEGP, followed by LEHR and MEGP-1. The highest ratio of direct ray was also observed in ELEGP followed by MEGP-1. In comparison of the radioactivity concentration ratios of tumor/liver, CRC and CNR were significantly decreased with smaller radioactivity concentration ratios. This effect was greater with larger spheres. According to the visual assessment, the acquisition time of 6, 6, and 3 min or longer was required using ELEGP collimator at 6, 24, and 72 h after administration, respectively. Physical assessment based on CNR and CRC also suggested that 6, 6, and 3 min or longer acquisition time was necessary at 6, 24, and 72 h after administration. CONCLUSION 177Lu-SPECT images generated via the Monte Carlo simulation suggested that the recommended acquisition time was 6 min or longer at 6 and 24 h and 3 min or longer at 72 h after administration.
Collapse
Affiliation(s)
- Yuya Sekikawa
- Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan
- Department of Radiological Technology, Faculty of Fukuoka Medical Technology, Teikyo University, 6-22 Misakimachi, Omuta, Fukuoka, 836-8505, Japan
| | - Keita Funada
- Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan
| | - Go Akamatsu
- National Institutes for Quantum and Radiological Science and Technology (QST), 4-9-1 Anagawa, Inage-ku, Chiba, 263-8555, Japan
| | - Kazuhiko Himuro
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan
| | - Akihiko Takahashi
- Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
| | - Shingo Baba
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan
| | - Masayuki Sasaki
- Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan
| |
Collapse
|
6
|
Monserrat Fuertes T, González García F, Peinado Montes M, Domínguez Grande M, Martín Fernández N, Gómez de Iturriaga Piña A, Mínguez Gabiña P. Description of the methodology for dosimetric quantification in treatments with 177Lu-DOTATATE. Rev Esp Med Nucl Imagen Mol 2021. [DOI: 10.1016/j.remnie.2021.03.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
7
|
Monserrat Fuertes T, González García FM, Peinado Montes MÁ, Domínguez Grande ML, Martín Fernández N, Gómez de Iturriaga Piña A, Mínguez Gabiña P. Description of the methodology for dosimetric quantification in treatments with 177Lu-DOTATATE. Rev Esp Med Nucl Imagen Mol 2021; 40:167-178. [PMID: 33811003 DOI: 10.1016/j.remn.2021.02.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Revised: 02/22/2021] [Accepted: 02/24/2021] [Indexed: 11/28/2022]
Abstract
Implementation of dosimetry calculations in the daily practice of Nuclear Medicine Departments is, at this time, a controversial issue, partly due to the lack of a standardized methodology that is accepted by all interested parties (patients, nuclear medicine physicians and medical physicists). However, since the publication of RD 601/2019 there is a legal obligation to implement it, despite the fact that it is a complex and high resource consumption procedure. The aim of this article is to review the theoretical bases of in vivo dosimetry in treatments with 177Lu-DOTATATE. The exposed methodology is the one proposed by the MIRD Committee (Medical Internal Radiation Dose) of the SNMMI (Society of Nuclear Medicine & Molecular Imaging). According to this method, the absorbed dose is obtained as the product of 2factors: the time-integrated activity of the radiopharmaceutical present in a source region and a geometrical factor S. This approach, which a priori seems simple, in practice requires several SPECT/CT acquisitions, several measurements of the whole body activity and taking several blood samples, as well as hours of image processing and computation. The systematic implementation of these calculations, in all the patients we treat, will allow us to obtain homogeneous data to correlate the absorbed doses in the lesions with the biological effect of the treatment. The final purpose of the dosimetry calculations is to be able to maximize the therapeutic effect in the lesions, controlling the radiotoxicity in the organs at risk.
Collapse
Affiliation(s)
- T Monserrat Fuertes
- Servicio de Radiofísica y Protección Radiológica, Hospital Universitario Central de Asturias, Oviedo, Asturias, España; Departamento de Cirugía, Radiología y Medicina Física, UPV/EHU, Leioa, Bizkaia, España.
| | - F M González García
- Servicio de Medicina Nuclear, Hospital Universitario Central de Asturias, Oviedo, Asturias, España
| | - M Á Peinado Montes
- Servicio de Radiofísica y Protección Radiológica, Hospital Universitario Central de Asturias, Oviedo, Asturias, España
| | - M L Domínguez Grande
- Servicio de Medicina Nuclear, Hospital Universitario Central de Asturias, Oviedo, Asturias, España
| | - N Martín Fernández
- Servicio de Medicina Nuclear, Hospital Universitario Central de Asturias, Oviedo, Asturias, España
| | - A Gómez de Iturriaga Piña
- Departamento de Cirugía, Radiología y Medicina Física, UPV/EHU, Leioa, Bizkaia, España; Servicio de Oncología Radioterápica, Hospital Universitario Gurutzeta-Cruces/Instituto de Investigación Sanitaria BioCruces, Barakaldo, Bizkaia, España
| | - P Mínguez Gabiña
- Unidad de Protección Radiológica y Radiofísica, Hospital Universitario Gurutzeta-Cruces/Instituto de Investigación Sanitaria BioCruces, Barakaldo, Bizkaia, España
| |
Collapse
|
8
|
Ramonaheng K, van Staden JA, du Raan H. The effect of calibration factors and recovery coefficients on 177Lu SPECT activity quantification accuracy: a Monte Carlo study. EJNMMI Phys 2021; 8:27. [PMID: 33738605 PMCID: PMC7973313 DOI: 10.1186/s40658-021-00365-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Accepted: 02/08/2021] [Indexed: 12/19/2022] Open
Abstract
BACKGROUND Different gamma camera calibration factor (CF) geometries have been proposed to convert SPECT data into units of activity concentration. However, no consensus has been reached on a standardised geometry. The CF is dependent on the selected geometry and is further affected by partial volume effects. This study investigated the effect of two CF geometries and their corresponding recovery coefficients (RCs) on the quantification accuracy of 177Lu SPECT images using Monte Carlo simulations. METHODS The CF geometries investigated were (i) a radioactive-sphere surrounded by non-radioactive water (sphere-CF) and (ii) a cylindrical phantom uniformly filled with radioactive water (cylinder-CF). Recovery coefficients were obtained using the sphere-CF and cylinder-CF, yielding the sphere-RC and cylinder-RC values, respectively, for partial volume correction (PVC). The quantification accuracy was evaluated using four different-sized spheres (15.6-65.4 ml) and a kidney model with known activity concentrations inside a cylindrical, torso and patient phantom. Images were reconstructed with the 3D OS-EM algorithm incorporating attenuation, scatter and detector-response corrections. Segmentation was performed using the physical size and a small cylindrical volume inside the cylinder for the sphere-CF and cylinder-CF, respectively. RESULTS The sphere quantification error (without PVC) was better for the sphere-CF (≤ - 5.54%) compared to the cylinder-CF (≤ - 20.90%), attributed to the similar geometry of the quantified and CF spheres. Partial volume correction yielded comparable results for the sphere-CF-RC (≤ 3.47%) and cylinder-CF-RC (≤ 3.53%). The accuracy of the kidney quantification was poorer (≤ 22.34%) for the sphere-CF without PVC compared to the cylinder-CF (≤ 2.44%). With PVC, the kidney quantification results improved and compared well for the sphere-CF-RC (≤ 3.50%) and the cylinder-CF-RC (≤ 3.45%). CONCLUSION The study demonstrated that upon careful selection of CF-RC combinations, comparable quantification errors (≤ 3.53%) were obtained between the sphere-CF-RC and cylinder-CF-RC, when all corrections were applied.
Collapse
Affiliation(s)
- Keamogetswe Ramonaheng
- Department of Medical Physics, Faculty of Health Sciences, University of the Free State, PO Box 339, Bloemfontein, 9300, South Africa.
| | - Johannes A van Staden
- Department of Medical Physics, Faculty of Health Sciences, University of the Free State, PO Box 339, Bloemfontein, 9300, South Africa
| | - Hanlie du Raan
- Department of Medical Physics, Faculty of Health Sciences, University of the Free State, PO Box 339, Bloemfontein, 9300, South Africa
| |
Collapse
|
9
|
Taprogge J, Wadsley J, Miles E, Flux GD. Recommendations for Multicentre Clinical Trials Involving Dosimetry for Molecular Radiotherapy. Clin Oncol (R Coll Radiol) 2021; 33:131-136. [PMID: 33342617 PMCID: PMC7818526 DOI: 10.1016/j.clon.2020.12.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Revised: 11/06/2020] [Accepted: 12/02/2020] [Indexed: 11/17/2022]
Abstract
Multicentre clinical trials involving a dosimetry component are becoming more prevalent in molecular radiotherapy and are essential to generate the evidence to support individualised approaches to treatment planning and to ensure that sufficient patients are recruited to achieve the statistical significance required. Quality assurance programmes should be considered to support the standardisation required to achieve meaningful results. Trials should be designed to ensure that dosimetry results from image acquisition systems across centres are comparable by incorporating steps to standardise the methodologies used for the quantification of images and dosimetry. Furthermore, it is essential to assess the expertise and resources available at each participating site prior to trial commencement. A quality assurance plan should be drawn up and training provided if necessary. Standardisation of quantification and dosimetry methodologies used in a trial are essential to ensure that results from different centres may be collated. In addition, appropriate uncertainty analysis should be carried out to correct for differences in methodologies between centres. Recommendations are provided to support dosimetry studies based on the experience of several previous and ongoing multicentre trials.
Collapse
Affiliation(s)
- J Taprogge
- National Radiotherapy Trials Quality Assurance (RTTQA) Group, Joint Department of Physics, Royal Marsden NHSFT, Sutton, UK; The Institute of Cancer Research, London, UK.
| | | | - E Miles
- National Radiotherapy Trials Quality Assurance (RTTQA) Group, Mount Vernon Cancer Centre, East and North Hertfordshire NHS Trust, Northwood, UK
| | - G D Flux
- The Institute of Cancer Research, London, UK; Joint Department of Physics, Royal Marsden NHSFT, Sutton, UK
| |
Collapse
|
10
|
López DF, Castro MA, Muñoz JM, Cárdenas-Perilla R. Reference values of mandibular condyles metabolic activity: A study using 99m Tc-MDP single-photon emission computed tomography. Orthod Craniofac Res 2020; 24:328-334. [PMID: 33090651 DOI: 10.1111/ocr.12434] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2020] [Revised: 09/13/2020] [Accepted: 10/15/2020] [Indexed: 11/28/2022]
Abstract
OBJECTIVE To assess the condylar bone metabolic activity in patients with temporomandibular joint health by measuring 99m Tc-MDP uptake using a single-photon emission computed tomography (SPECT) to establish reference values of the uptake difference between condyles and the ratio with respect to the clivus. SETTING AND SAMPLE POPULATION Eighty consecutive patients of both sexes who were admitted to a Nuclear Medicine Centre between 2017 and 2019 were included in the study. METHOD This was an observational cross-sectional study in patients with SPECT indications to evaluate pathologies other than those of the temporomandibular joint. The values of the total and normalized counts in a fixed region of interest of five trans-axial slides were obtained to assess the percentage difference between the sides and the uptake ratio. The reference values are expressed as median and 5th and 95th percentiles. RESULTS The sample included 53 women (66.25%) and 27 men (33.75%) aged 15-55 years. The percentage of uptake difference between condyles was 5.04% (0.46-14.78) for men and 5.17% (0.27-13.21) for women (difference not significant, P = .9). The uptake difference was below 10% in 85% of the subjects (n = 68). The ratio values for total counts in women (0.87, 0.46-1.33) were significantly different (P = .0030) from those in men (1.08, 0.61-2.09). No significant correlation with age was found. CONCLUSIONS These new reference ranges are applicable to the diagnosis of unilateral and bilateral condylar hyperplasia.
Collapse
Affiliation(s)
- Diego Fernando López
- Orthodontics Graduate Program, School of Dentistry, Universidad del Valle, Cali, Colombia
| | - María Angélica Castro
- Orthodontics Graduate Program, School of Dentistry, Universidad del Valle, Cali, Colombia
| | | | | |
Collapse
|
11
|
Finocchiaro D, Gear JI, Fioroni F, Flux GD, Murray I, Castellani G, Versari A, Iori M, Grassi E. Uncertainty analysis of tumour absorbed dose calculations in molecular radiotherapy. EJNMMI Phys 2020; 7:63. [PMID: 33044651 PMCID: PMC7550507 DOI: 10.1186/s40658-020-00328-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Accepted: 09/16/2020] [Indexed: 01/25/2023] Open
Abstract
BACKGROUND Internal dosimetry evaluation consists of a multi-step process ranging from imaging acquisition to absorbed dose calculations. Assessment of uncertainty is complicated and, for that reason, it is commonly ignored in clinical routine. However, it is essential for adequate interpretation of the results. Recently, the EANM published a practical guidance on uncertainty analysis for molecular radiotherapy based on the application of the law of propagation of uncertainty. In this study, we investigated the overall uncertainty on a sample of a patient following the EANM guidelines. The aim of this study was to provide an indication of the typical uncertainties that may be expected from performing dosimetry, to determine parameters that have the greatest effect on the accuracy of calculations and to consider the potential improvements that could be made if these effects were reduced. RESULTS Absorbed doses and the relative uncertainties were calculated for a sample of 49 patients and a total of 154 tumours. A wide range of relative absorbed dose uncertainty values was observed (14-102%). Uncertainties associated with each quantity along the absorbed dose calculation chain (i.e. volume, recovery coefficient, calibration factor, activity, time-activity curve fitting, time-integrated activity and absorbed dose) were estimated. An equation was derived to describe the relationship between the uncertainty in the absorbed dose and the volume. The largest source of error was the VOI delineation. By postulating different values of FWHM, the impact of the imaging system spatial resolution on the uncertainties was investigated. DISCUSSION To the best of our knowledge, this is the first analysis of uncertainty in molecular radiotherapy based on a cohort of clinical cases. Wide inter-lesion variability of absorbed dose uncertainty was observed. Hence, a proper assessment of the uncertainties associated with the calculations should be considered as a basic scientific standard. A model for a quick estimate of uncertainty without implementing the entire error propagation schema, which may be useful in clinical practice, was presented. Ameliorating spatial resolution may be in future the key factor for accurate absorbed dose assessment.
Collapse
Affiliation(s)
- Domenico Finocchiaro
- Medical Physics Unit, Azienda Unità Sanitaria Locale di Reggio Emilia - IRCCS, Reggio Emilia, Italy.,Department of Physics and Astronomy, University of Bologna, Bologna, Italy
| | - Jonathan I Gear
- The Royal Marsden NHS Foundation Trust & Institute of Cancer Research, Downs Road, Sutton, SM2 5PT, UK
| | - Federica Fioroni
- Medical Physics Unit, Azienda Unità Sanitaria Locale di Reggio Emilia - IRCCS, Reggio Emilia, Italy.
| | - Glenn D Flux
- The Royal Marsden NHS Foundation Trust & Institute of Cancer Research, Downs Road, Sutton, SM2 5PT, UK
| | - Iain Murray
- The Royal Marsden NHS Foundation Trust & Institute of Cancer Research, Downs Road, Sutton, SM2 5PT, UK
| | - Gastone Castellani
- Department of Physics and Astronomy, University of Bologna, Bologna, Italy
| | - Annibale Versari
- Nuclear Medicine Unit, Azienda Unità Sanitaria Locale di Reggio Emilia - IRCCS, Reggio Emilia, Italy
| | - Mauro Iori
- Medical Physics Unit, Azienda Unità Sanitaria Locale di Reggio Emilia - IRCCS, Reggio Emilia, Italy
| | - Elisa Grassi
- Medical Physics Unit, Azienda Unità Sanitaria Locale di Reggio Emilia - IRCCS, Reggio Emilia, Italy
| |
Collapse
|
12
|
Ramonaheng K, van Staden JA, du Raan H. Validation of a Monte Carlo modelled gamma camera for Lutetium-177 imaging. Appl Radiat Isot 2020; 163:109200. [PMID: 32561041 DOI: 10.1016/j.apradiso.2020.109200] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2019] [Revised: 02/11/2020] [Accepted: 04/08/2020] [Indexed: 10/24/2022]
Abstract
This study validated a model of the Siemens Symbia T16 dual-head SPECT/CT gamma camera created using the Monte Carlo program SIMIND for 177Lu. The validation was done by comparing experimental and simulated gamma camera performance criteria tests for the 177Lu 208 keV photopeak with a medium-energy collimator. Results showed good agreement between the experimental and simulated values. These results illustrated that SIMIND could emulate the Symbia T16 successfully and therefore, can be used with confidence to model 177Lu images.
Collapse
Affiliation(s)
- K Ramonaheng
- Department of Medical Physics, University of the Free State, PO Box 339, Bloemfontein, 9300, South Africa.
| | - J A van Staden
- Department of Medical Physics, University of the Free State, PO Box 339, Bloemfontein, 9300, South Africa
| | - H du Raan
- Department of Medical Physics, University of the Free State, PO Box 339, Bloemfontein, 9300, South Africa
| |
Collapse
|
13
|
Frezza A, Desport C, Uribe C, Zhao W, Celler A, Després P, Beauregard JM. Comprehensive SPECT/CT system characterization and calibration for 177Lu quantitative SPECT (QSPECT) with dead-time correction. EJNMMI Phys 2020; 7:10. [PMID: 32060777 PMCID: PMC7021856 DOI: 10.1186/s40658-020-0275-6] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2019] [Accepted: 01/26/2020] [Indexed: 12/31/2022] Open
Abstract
Background Personalization of 177Lu-based radionuclide therapy requires implementation of dosimetry methods that are both accurate and practical enough for routine clinical use. Quantitative single-photon emission computed tomography/computed tomography (QSPECT/CT) is the preferred scanning modality to achieve this and necessitates characterizing the response of the camera, and calibrating it, over the full range of therapeutic activities and system capacity. Various methods to determine the camera calibration factor (CF) and the deadtime constant (τ) were investigated, with the aim to design a simple and robust protocol for quantitative 177Lu imaging. Methods The SPECT/CT camera was equipped with a medium energy collimator. Multiple phantoms were used to reproduce various attenuation conditions: rod sources in air or water-equivalent media, as well as a Jaszczak phantom with inserts. Planar and tomographic images of a wide range of activities were acquired, with multiple energy windows for scatter correction (double or triple energy window technique) as well as count rate monitoring over a large spectrum of energy. Dead time was modelled using the paralysable model. CF and τ were deduced by curve fitting either separately in two steps (CF determined first using a subset of low-activity acquisitions, then τ determined using the full range of activity) or at once (both CF and τ determined using the full range of activity). Total or segmented activity in the SPECT field of view was computed. Finally, these methods were compared in terms of accuracy to recover the known activity, in particular when planar-derived parameters were applied to the SPECT data. Results The SPECT camera was shown to operate as expected on a finite count rate range (up to ~ 350 kcps over the entire energy spectrum). CF and τ from planar (sources in air) and SPECT segmented Jaszczak data yielded a very good agreement (CF < 1% and τ < 3%). Determining CF and τ from a single curve fit made dead-time-corrected images less prone to overestimating recovered activity. Using triple-energy window scatter correction while acquiring one or more additional energy window(s) to enable wide-spectrum count rate monitoring (i.e. ranging 55–250 or 18–680 keV) yielded the most consistent results across the various geometries. The final, planar-derived calibration parameters for our system were a CF of 9.36 ± 0.01 cps/MBq and a τ of 0.550 ± 0.003 μs. Using the latter, the activity in a Jaszczak phantom could be quantified by QSPECT with an accuracy of 0.02 ± 1.10%. Conclusions Serial planar acquisitions of sources in air using an activity range covering the full operational capacity of the SPECT/CT system, with multiple energy windows for wide-spectrum count rate monitoring, and followed by simultaneous determination of CF and τ using a single equation derived from the paralysable model, constitutes a practical method to enable accurate dead-time-corrected QSPECT imaging in a post-177Lu radionuclide therapy setting.
Collapse
Affiliation(s)
- Andrea Frezza
- Cancer Research Center, Université Laval, Quebec City, QC, Canada.,Department of Physics, Engineering Physics and Optics, Université Laval, Quebec City, QC, Canada.,Oncology Division, CHU de Québec - Université Laval Research Center, Quebec City, QC, Canada
| | - Corentin Desport
- Cancer Research Center, Université Laval, Quebec City, QC, Canada.,Department of Physics, Engineering Physics and Optics, Université Laval, Quebec City, QC, Canada.,Oncology Division, CHU de Québec - Université Laval Research Center, Quebec City, QC, Canada
| | - Carlos Uribe
- Functional Imaging Department, BC Cancer, Vancouver, BC, Canada
| | - Wei Zhao
- Medical Imaging Research Group, Department of Radiology, University of British Columbia, Vancouver, BC, Canada
| | - Anna Celler
- Medical Imaging Research Group, Department of Radiology, University of British Columbia, Vancouver, BC, Canada
| | - Philippe Després
- Cancer Research Center, Université Laval, Quebec City, QC, Canada.,Department of Physics, Engineering Physics and Optics, Université Laval, Quebec City, QC, Canada.,Oncology Division, CHU de Québec - Université Laval Research Center, Quebec City, QC, Canada.,Department of Radiation Oncology, CHU de Québec - Université Laval, Quebec City, QC, Canada
| | - Jean-Mathieu Beauregard
- Cancer Research Center, Université Laval, Quebec City, QC, Canada. .,Oncology Division, CHU de Québec - Université Laval Research Center, Quebec City, QC, Canada. .,Department of Radiology and Nuclear Medicine, Université Laval, Quebec City, QC, Canada. .,Department of Medical Imaging, CHU de Québec - Université Laval, 11 côte du Palais, Quebec City, QC, G1R 2J6, Canada.
| |
Collapse
|
14
|
Abstract
The continuous development of SPECT over the past 50 years has led to improved image quality and increased diagnostic confidence. The most influential developments include the realization of hybrid SPECT/CT devices, as well as the implementation of attenuation correction and iterative image reconstruction techniques. These developments have led to a preference for SPECT/CT devices over SPECT-only systems and to the widespread adoption of the former, strengthening the role of SPECT/CT as the workhorse of Nuclear Medicine imaging. New trends in the ongoing development of SPECT/CT are diverse. For example, whole-body SPECT/CT images, consisting of acquisitions from multiple consecutive bed positions in the manner of PET/CT, are increasingly performed. Additionally, in recent years, some interesting approaches in detector technology have found their way into commercial products. For example, some SPECT cameras dedicated to specific organs employ semiconductor detectors made of cadmium telluride or cadmium zinc telluride, which have been shown to increase the obtainable image quality by offering a higher sensitivity and energy resolution. However, the advent of quantitative SPECT/CT which, like PET, can quantify the amount of tracer in terms of Bq/mL or as a standardized uptake value could be regarded as most important development. It is a major innovation that will lead to increased diagnostic accuracy and confidence, especially in longitudinal studies and in the monitoring of treatment response. The current work comprises two main aspects. At first, physical and technical fundamentals of SPECT image formation are described and necessary prerequisites of quantitative SPECT/CT are reviewed. Additionally, the typically achievable quantitative accuracy based on reports from the literature is given. Second, an extensive list of studies reporting on clinical applications of quantitative SPECT/CT is provided and reviewed.
Collapse
Affiliation(s)
- Philipp Ritt
- Clinic of Nuclear Medicine, University Hospital Erlangen, Ulmenweg 18, 91054, Erlangen, Germany.
| | - Torsten Kuwert
- Clinic of Nuclear Medicine, University Hospital Erlangen, Ulmenweg 18, 91054, Erlangen, Germany
| |
Collapse
|
15
|
Benabdallah N, Bernardini M, Bianciardi M, de Labriolle-Vaylet C, Franck D, Desbrée A. 223Ra-dichloride therapy of bone metastasis: optimization of SPECT images for quantification. EJNMMI Res 2019; 9:20. [PMID: 30790144 PMCID: PMC6384291 DOI: 10.1186/s13550-019-0488-7] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2018] [Accepted: 02/04/2019] [Indexed: 12/11/2022] Open
Abstract
BACKGROUND 223Ra imaging is crucial to evaluate the successfulness of the therapy of bone metastasis of castration-resistant prostate cancer (CRPC). The goals of this study were to establish a quantitative tomographic 223Ra imaging protocol with clinically achievable conditions, as well as to investigate its usefulness and limitations. We performed several experiments using the Infinia Hawkeye 4 gamma camera (GE) and physical phantoms in order to assess the optimal image acquisition and reconstruction parameters, such as the windows setting, as well as the iteration number and filter of the reconstruction algorithm. Then, based on the MIRD pamphlet 23, we used a NEMA phantom and an anthropomorphic TORSO® phantom to calibrate the gamma camera and investigate the accuracy of quantification. RESULTS Experiences showed that the 85 keV ± 20%, 154 keV ± 10%, and 270 keV ± 10% energy windows are the most suitable for 223Ra imaging. The study with the NEMA phantom showed that the OSEM algorithm with 2 iterations, 10 subsets, and the Butterworth filter offered the best compromise between contrast and noise. Moreover, the calibration factors for different sphere sizes (26.5 ml, 11.5 ml, and 5.6 ml) were constant for 223Ra concentrations ranging between 6.5 and 22.8 kBq/ml. The values found are 73.7 cts/s/MBq, 43.8 cts/s/MBq, and 43.4 cts/s/MBq for 26.5 ml, 11.5 ml, and 5.6 ml sphere, respectively. For concentration lower than 6.5 kBq/ml, the calibration factors exhibited greater variability pointing out the limitations of SPECT/CT imaging for quantification. By the use of a TORSO® phantom, we simulated several tumors to normal tissue ratios as close as possible to clinical conditions. Using the calibration factors obtained with the NEMA phantom, for 223Ra concentrations higher than 8 kBq/ml, we were able to quantify the activity with an error inferior to 18.8% in a 5.6 ml lesion. CONCLUSIONS Absolute quantitative 223Ra SPECT imaging appears feasible once the dimension of the target is determined. Further evaluation should be needed to apply the calibration factor-based quantitation to clinical 223Ra SPECT/CT imaging. This will open the possibility for patient-specific 223Ra treatment planning and therapeutic outcome prediction in patients.
Collapse
Affiliation(s)
- Nadia Benabdallah
- Internal Dose Assessment Laboratory, Institute for Radiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
| | - Michela Bernardini
- Nuclear Medicine Department, European Hospital George Pompidou (HEGP), Paris, France
| | - Marta Bianciardi
- Department of Radiology, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Boston, USA
| | - Claire de Labriolle-Vaylet
- UPMC, Univ Paris 06 Biophysics, Paris, France
- Nuclear Medicine Department, Trousseau Hospital, Paris, France
| | - Didier Franck
- Internal Dose Assessment Laboratory, Institute for Radiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
| | - Aurélie Desbrée
- Internal Dose Assessment Laboratory, Institute for Radiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
| |
Collapse
|
16
|
Carvalho SM, Costa APM, Ramos CD, Castelo JHM, Brunetto SQ, Bonifácio DAB. Influence of the SPECT calibration source position on the absorbed dose calculation for 131I-NaI therapy using GATE simulations. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2018; 38:1284-1292. [PMID: 30019693 DOI: 10.1088/1361-6498/aad42a] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Many research groups have studied nuclear medicine image quantification to improve its accuracy in dose estimation. This work aims to evaluate the influence of the source calibration position for absorbed dose calculation for a 131I-NaI therapy using Monte Carlo (MC) simulations. The calibration approach consisted of a cylindrical phantom filled with water. A cylindrical 131I source with 361.1 ± 3.6 kBq ml-1 was positioned at the center of the phantom and its outer part. Images were acquired with 150 00 counts per projection image acquired with SPECT detector (high counts density-HCD) and 3000 counts per projection (low counts density-LCD). MC simulations, performed with GATE code, were validated by comparing the S values of a water sphere uniformly filled with 131I, as from the sphere model of OLINDA/EXM 1.1. Calibration factors deviation between central and peripheral calibrations is more significant for HCD (18.3%) than for LCD images (3.7%). The 3D dose distribution map obtained from GATE resulted in a dose factor equal to 1.5 × 10-3 mGy/(MBq.s). For both HCD and LCD images, the commonly used approach, which employs the central source calibration to obtain the dose from a peripheral source, resulted in dose overestimation. Results suggest that organ dose calculation can be improved considering the organ position in the field of view. Finally, patients' radiation protection in dosimetry studies could be improved considering the calibration source position, due to the superior accuracy in dose calculation.
Collapse
Affiliation(s)
- Samira M Carvalho
- Institute of Radiation Protection and Dosimetry-IRD/CNEN, Rio de Janeiro, RJ, Brazil
| | | | | | | | | | | |
Collapse
|
17
|
Karimi Ghodoosi E, D'Alessandria C, Li Y, Bartel A, Köhner M, Höllriegl V, Navab N, Eiber M, Li WB, Frey E, Ziegler S. The effect of attenuation map, scatter energy window width, and volume of interest on the calibration factor calculation in quantitative 177Lu SPECT imaging: Simulation and phantom study. Phys Med 2018; 56:74-80. [DOI: 10.1016/j.ejmp.2018.11.009] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/07/2018] [Revised: 11/07/2018] [Accepted: 11/15/2018] [Indexed: 10/27/2022] Open
|
18
|
Ljungberg M, Sjogreen Gleisner K. 3-D Image-Based Dosimetry in Radionuclide Therapy. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2018. [DOI: 10.1109/trpms.2018.2860563] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
19
|
Lassmann M, Eberlein U. The Relevance of Dosimetry in Precision Medicine. J Nucl Med 2018; 59:1494-1499. [PMID: 30002109 DOI: 10.2967/jnumed.117.206649] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2018] [Accepted: 06/29/2018] [Indexed: 11/16/2022] Open
Abstract
The aim of this review is to provide an overview of the most recent technologic developments in state-of-the-art equipment and tools for dosimetry in radionuclide therapies. This includes, but is not restricted to, calibration methods for imaging systems. In addition, a summary of new developments that consider the influence of small-scale dosimetry and of biologic effects on radionuclide therapies is given. Finally, the current limitations of patient-specific dosimetry such as bone-marrow dosimetry or dosimetry of α-emitters are discussed.
Collapse
Affiliation(s)
- Michael Lassmann
- Klinik und Poliklinik für Nuklearmedizin, Universitätsklinikum Würzburg, Würzburg, Germany
| | - Uta Eberlein
- Klinik und Poliklinik für Nuklearmedizin, Universitätsklinikum Würzburg, Würzburg, Germany
| |
Collapse
|
20
|
Tran-Gia J, Lassmann M. Characterization of Noise and Resolution for Quantitative 177Lu SPECT/CT with xSPECT Quant. J Nucl Med 2018; 60:50-59. [DOI: 10.2967/jnumed.118.211094] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2018] [Accepted: 06/14/2018] [Indexed: 12/29/2022] Open
|
21
|
Halty A, Badel JN, Kochebina O, Sarrut D. Image-based SPECT calibration based on the evaluation of the Fraction of Activity in the Field of View. EJNMMI Phys 2018; 5:11. [PMID: 29766354 PMCID: PMC5953912 DOI: 10.1186/s40658-018-0209-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2017] [Accepted: 03/16/2018] [Indexed: 11/27/2022] Open
Abstract
Background SPECT quantification is important for dosimetry in targeted radionuclide therapy (TRT) and the calibration of SPECT images is a crucial stage for image quantification. The current standardized calibration protocol (MIRD 23) uses phantom acquisitions to derive a global calibration factor in specific conditions. It thus requires specific acquisitions for every clinical protocols. We proposed an alternative and complementary image-based calibration method that allows to determine a calibration factor adapted to each patient, radionuclide, and acquisition protocol and that may also be used as an additional independent calibration. Results The proposed method relies on a SPECT/CT acquisition of a given region of interest and an initial whole-body (WB) planar image. First, the conjugate view of WB planar images is computed after scatter and attenuation correction. 3D SPECT images are reconstructed with scatter, attenuation, and collimator-detector response (CDR) corrections and corrected from apparent dead-time. The field of view (FOV) of the SPECT image is then projected on the corrected WB planar image. The fraction of activity located in the area corresponding to the SPECT FOV is then calculated based on the counts on the corrected WB planar image. The Fraction of Activity in Field Of View (FAF) is then proposed to compute the calibration factor as the total number of counts in the SPECT image divided by this activity. Quantification accuracy was compared with the standard calibration method both with phantom experiments and on patient data. Both standard and image-based calibrations give good accuracy on large region of interest on phantom experiments (less than 7% of relative difference compared to ground truth). Apparent dead-time correction allows to reduce the uncertainty associated with standard calibration from 2.5 to 1%. The differences found between both methods were lower than the uncertainty range of the standard calibration (<3%). In patient data, although no ground truth was available, both methods give similar calibration factor (average difference 3.64%). Conclusions A calibration factor may be computed directly from the acquired SPECT image providing that a WB planar image is also available and if both acquisitions are performed before biological elimination. This method does not require to perform phantom acquisition for every different acquisition conditions and may serve to double check the calibration with an independent factor.
Collapse
Affiliation(s)
- Adrien Halty
- Univ Lyon, INSA-Lyon, Université Lyon 1, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, 69008, France. .,Univ Lyon, Centre Léon Bérard, Lyon, 69008, France.
| | | | - Olga Kochebina
- Univ Lyon, INSA-Lyon, Université Lyon 1, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, 69008, France
| | - David Sarrut
- Univ Lyon, INSA-Lyon, Université Lyon 1, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, 69008, France.,Univ Lyon, Centre Léon Bérard, Lyon, 69008, France
| |
Collapse
|
22
|
Uribe CF, Esquinas PL, Tanguay J, Gonzalez M, Gaudin E, Beauregard JM, Celler A. Accuracy of 177Lu activity quantification in SPECT imaging: a phantom study. EJNMMI Phys 2017; 4:2. [PMID: 28063068 PMCID: PMC5218957 DOI: 10.1186/s40658-016-0170-3] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2016] [Accepted: 12/20/2016] [Indexed: 12/17/2022] Open
Abstract
BACKGROUND The aim of the study is to assess accuracy of activity quantification of 177Lu studies performed according to recommendations provided by the committee on Medical Internal Radiation Dose (MIRD) pamphlets 23 and 26. The performances of two scatter correction and three segmentation methods were compared. Additionally, the accuracy of tomographic and planar methods for determination of the camera normalization factor (CNF) was evaluated. Eight phantoms containing inserts of different sizes and shapes placed in air, water, and radioactive background were scanned using a Siemens SymbiaT SPECT/CT camera. Planar and tomographic scans with 177Lu sources were used to measure CNF. Images were reconstructed with our SPEQToR software using resolution recovery, attenuation, and two scatter correction methods (analytical photon distribution interpolated (APDI) and triple energy window (TEW)). Segmentation was performed using a fixed threshold method for both air and cold water scans. For hot water experiments three segmentation methods were compared as folows: a 40% fixed threshold, segmentation based on CT images, and our iterative adaptive dual thresholding (IADT). Quantification error, defined as the percent difference between experimental and true activities, was evaluated. RESULTS Quantification error for scans in air was better for TEW scatter correction (<6%) than for APDI (<11%). This trend was reversed for scans in water (<10% for APDI and <14% for TEW). For hot water, the best results (<18% for small objects and <5% for objects >100 ml) were obtained when APDI and IADT were used for scatter correction and segmentation, respectively. Additionally, we showed that planar acquisitions with scatter correction and tomographic scans provide similar CNF values. This is an important finding because planar acquisitions are easier to perform than tomographic scans. TEW and APDI resulted in similar quantification errors with APDI showing a small advantage for objects placed in medium with non-uniform density. CONCLUSIONS Following the MIRD recommendations for data acquisition and reconstruction resulted in accurate activity quantification (errors <5% for large objects). However, techniques for better organ/tumor segmentation must still be developed.
Collapse
Affiliation(s)
- Carlos F Uribe
- Medical Imaging Research Group, Department of Radiology, University of British Columbia, Vancouver, British Colombia, Canada.
- Department of Physics and Astronomy, University of British Columbia, Vancouver, British Colombia, Canada.
- Department of Molecular Oncology, BC Cancer Research Centre, Vancouver, British Colombia, Canada.
| | - Pedro L Esquinas
- Medical Imaging Research Group, Department of Radiology, University of British Columbia, Vancouver, British Colombia, Canada
- Department of Physics and Astronomy, University of British Columbia, Vancouver, British Colombia, Canada
| | - Jesse Tanguay
- Medical Imaging Research Group, Department of Radiology, University of British Columbia, Vancouver, British Colombia, Canada
| | - Marjorie Gonzalez
- Vancouver Coastal Health Authority, Vancouver, British Colombia, Canada
| | - Emilie Gaudin
- Department of Physics, Engineering Physics and Optics, Université Laval, Quebec City, Quebec, Canada
| | - Jean-Mathieu Beauregard
- Department of Medical Imaging, CHU de Quebec-Université Laval, Quebec City, Quebec, Canada
- Department of Radiology and Nuclear Medicine, Université Laval, Quebec City, Quebec, Canada
| | - Anna Celler
- Medical Imaging Research Group, Department of Radiology, University of British Columbia, Vancouver, British Colombia, Canada
| |
Collapse
|
23
|
Uncertainty Analysis in the Calibration of an Emission Tomography System for Quantitative Imaging. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2017; 2017:9830386. [PMID: 29312467 PMCID: PMC5660760 DOI: 10.1155/2017/9830386] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/12/2017] [Accepted: 08/15/2017] [Indexed: 11/25/2022]
Abstract
It is generally acknowledged that calibration of the imaging system (be it a SPECT or a PET scanner) is one of the critical components associated with in vivo activity quantification in nuclear medicine. The system calibration is generally performed through the acquisition of a source with a known amount of radioactivity. The decay-corrected calibration factor is the “output” quantity in a measurement model for the process. This quantity is a function of a number of “input” variables, including total counts in the volume of interest (VOI), radionuclide activity concentration, source volume, acquisition duration, radionuclide half-life, and calibration time of the radionuclide. Uncertainties in the input variables propagate through the calculation to the “combined” uncertainty in the output quantity. In the present study, using the general formula given in the GUM (Guide to the Expression of Uncertainty in Measurement) for aggregating uncertainty components, we derive a practical relation to assess the combined standard uncertainty for the calibration factor of an emission tomography system. At a time of increasing need for accuracy in quantification studies, the proposed approach has the potential to be easily implemented in clinical practice.
Collapse
|
24
|
Mezzenga E, D’Errico V, D’Arienzo M, Strigari L, Panagiota K, Matteucci F, Severi S, Paganelli G, Fenwick A, Bianchini D, Marcocci F, Sarnelli A. Quantitative accuracy of 177Lu SPECT imaging for molecular radiotherapy. PLoS One 2017; 12:e0182888. [PMID: 28806773 PMCID: PMC5564164 DOI: 10.1371/journal.pone.0182888] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2016] [Accepted: 07/26/2017] [Indexed: 11/18/2022] Open
Abstract
The purpose of this study is to investigate the optimal reference geometry for gamma camera calibration. Yet another question of interest was to assess the influence of the number of 3D Ordered Subsets Expectation Maximization (3D-OSEM) updates on activity quantification for SPECT imaging with 177Lu. The accuracy of 177Lu activity quantification was assessed both in small and in large objects. Two different reference geometries, namely a cylindrical homogeneous phantom and a Jaszczak 16 ml sphere surrounded by cold water, were used to determine the gamma camera calibration factor of a commercial SPECT/CT system. Moreover, the noise level and the concentration recovery coefficient were evaluated as a function of the number of 3D-OSEM updates by using the SPECT/CT images of the reference geometry phantoms and those of a cold Jaszczak phantom with three hot spheres (16ml, 8ml and 4ml), respectively. The optimal choice of the number of 3D-OSEM updates was based on a compromise between the noise level achievable in the reconstructed SPECT images and the concentration recovery coefficients. The quantitative accuracy achievable was finally validated on a test phantom, where a spherical insert composed of two concentric spheres was used to simulate a lesion in a warm background. Our data confirm and extend previous observations. Using the calibration factor obtained with the cylindrical homogeneous phantom and the Jaszczak 16 ml sphere, the recovered activity in the test phantom was underestimated by -16.4% and -24.8%, respectively. Our work has led us to conclude that gamma camera calibration performed with large homogeneous phantom outperforms calibration executed with the Jaszczak 16ml sphere. Furthermore, the results obtained support the assumption that approximately 50 OSEM updates represent a good trade-off to reach convergence in small volumes, meanwhile minimizing the noise level.
Collapse
Affiliation(s)
- Emilio Mezzenga
- Medical Physics Unit, Istituto Scientifico Romagnolo per lo Studio e la
Cura dei Tumori (IRST) IRCCS, Meldola, Italy
- * E-mail:
| | - Vincenzo D’Errico
- Medical Physics Unit, Istituto Scientifico Romagnolo per lo Studio e la
Cura dei Tumori (IRST) IRCCS, Meldola, Italy
| | - Marco D’Arienzo
- National Institute of Ionizing Radiation Metrology, ENEA CR Casaccia,
Rome, Italy
| | - Lidia Strigari
- Laboratory of Medical Physics and Expert Systems, Regina Elena National
Cancer Institute, Rome, Italy
| | - Koutla Panagiota
- Department of Physics, Aristotle University of Thessaloniki,
Thessaloniki, Greece
| | - Federica Matteucci
- Nuclear Medicine Unit, Istituto Scientifico Romagnolo per lo Studio e la
Cura dei Tumori (IRST) IRCCS, Meldola, Italy
| | - Stefano Severi
- Nuclear Medicine Unit, Istituto Scientifico Romagnolo per lo Studio e la
Cura dei Tumori (IRST) IRCCS, Meldola, Italy
| | - Giovanni Paganelli
- Nuclear Medicine Unit, Istituto Scientifico Romagnolo per lo Studio e la
Cura dei Tumori (IRST) IRCCS, Meldola, Italy
| | - Andrew Fenwick
- National Physical Laboratory, Hampton Road, Teddington, United
Kingdom
| | - David Bianchini
- Medical Physics Unit, Istituto Scientifico Romagnolo per lo Studio e la
Cura dei Tumori (IRST) IRCCS, Meldola, Italy
| | - Francesco Marcocci
- Medical Physics Unit, Istituto Scientifico Romagnolo per lo Studio e la
Cura dei Tumori (IRST) IRCCS, Meldola, Italy
| | - Anna Sarnelli
- Medical Physics Unit, Istituto Scientifico Romagnolo per lo Studio e la
Cura dei Tumori (IRST) IRCCS, Meldola, Italy
| |
Collapse
|
25
|
D’Arienzo M, Cozzella M, Fazio A, De Felice P, Iaccarino G, D’Andrea M, Ungania S, Cazzato M, Schmidt K, Kimiaei S, Strigari L. Quantitative 177 Lu SPECT imaging using advanced correction algorithms in non-reference geometry. Phys Med 2016; 32:1745-1752. [DOI: 10.1016/j.ejmp.2016.09.014] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/17/2016] [Revised: 08/09/2016] [Accepted: 09/16/2016] [Indexed: 11/25/2022] Open
|
26
|
Geometrical parameters and scattered radiation effects on the extrinsic sensitivity and counting efficiency of a rectangular gamma camera. Appl Radiat Isot 2016; 118:131-135. [PMID: 27640173 DOI: 10.1016/j.apradiso.2016.09.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2016] [Revised: 09/06/2016] [Accepted: 09/06/2016] [Indexed: 11/21/2022]
Abstract
A point source is used to investigate the effect of water phantom thickness and source-to-detector distance (SDD) on the sensitivity and counting efficiency of a rectangular detector gamma camera. The increase in water thickness resulted in an increase in scatter fraction, a decrease in sensitivity, and counting efficiency. The increase in SDD resulted in a decrease in sensitivity and an increase in counting efficiency. An SDD of 0.79±0.02m is found to provide a good compromise for acceptable sensitivity and reasonable counting efficiency.
Collapse
|