1
|
Kim J, Kim JY, Bae SE, Song K, Park JH. Review of the development in determination of 129I amount and the isotope ratio of 129I/127I using mass spectrometric measurements. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106476] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
2
|
Hurtado-Bermúdez S, Mas JL. Determination of 210Po in low-level wild bilberries reference material for quality control assurance in environmental analysis using extraction chromatography and α-particle spectroscopy. RADIOCHIM ACTA 2019. [DOI: 10.1515/ract-2019-3141] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Abstract
Certified reference materials (CRM) are being widely used for quality control assurance in environmental analysis. For certain CRM, the analytes and/or the range of concentrations are not be available or certified at all. The Joint Research Centre – Institute for Reference Materials and Measurements (JRC-IRMM) of the European Commission has issued a CRM of Wild Berries (IRMM-426) in order to validate radionuclide measurement methods for activity concentrations of the natural radionuclide 40K and the anthropogenic nuclides 90Sr and 137Cs, but not for 210Po. The aim of the work was to determine low-level activity concentration of 210Po in these wild berries. The activity concentration of 210Po was assessed by α-particle spectroscopy after dissolution of the sample by wet digestion and chemical isolation of Po by extraction chromatography. According to the time elapsed since sample collection, the results here shown can be useful not only for ultra low-level analysis of 210Po but also for 210Pb in the reference material.
Collapse
Affiliation(s)
- Santiago Hurtado-Bermúdez
- Centro de Investigación Tecnología e Innovación , Universidad de Sevilla (CITIUS) , Av. Reina Mercedes 4B , 41012 Sevilla , Spain , Phone: +34-954559750
| | - José Luis Mas
- Dpto. Física Aplicada I , Escuela Universitaria Politécnica, Universidad de Sevilla , Sevilla , Spain
| |
Collapse
|
3
|
Yang G, Tazoe H, Yamada M. Improved approach for routine monitoring of 129I activity and 129I/127I atom ratio in environmental samples using TMAH extraction and ICP-MS/MS. Anal Chim Acta 2018; 1008:66-73. [DOI: 10.1016/j.aca.2017.12.049] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2017] [Revised: 12/28/2017] [Accepted: 12/29/2017] [Indexed: 12/01/2022]
|