Absolute Luminescence Efficiency of Europium-Doped Calcium Fluoride (CaF2:Eu) Single Crystals under X-ray Excitation. CRYSTALS 2019. [DOI: 10.3390/cryst9050234] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The absolute luminescence efficiency (AE) of a calcium fluoride (CaF2:Eu) single crystal doped with europium was studied using X-ray energies met in general radiography. A CaF2:Eu single crystal with dimensions of 10 × 10 × 10 mm3 was irradiated by X-rays. The emission light photon intensity of the CaF2:Eu sample was evaluated by measuring AE within the X-ray range from 50 to 130 kV. The results of this work were compared with data obtained under similar conditions for the commercially employed medical imaging modalities, Bi4Ge3O12 and Lu2SiO5:Ce single crystals. The compatibility of the light emitted by the CaF2:Eu crystal, with the sensitivity of optical sensors, was also examined. The AE of the 10 × 10 × 10 mm3 CaF2:Eu crystal peaked in the range from 70 to 90 kV (22.22 efficiency units; E.U). The light emitted from CaF2:Eu is compatible with photocathodes, charge coupled devices (CCD), and silicon photomultipliers, which are used as radiation sensors in medical imaging systems. Considering the AE results in the examined energies, as well as the spectral compatibility with various photodetectors, a CaF2:Eu single crystal could be considered for radiographic applications, including the detection of charged particles and soft gamma rays.
Collapse
|
2
|
Abstract
Background: The aim of the present study was to assess the upper information content bound of positron emission tomography (PET) images, by means of the information capacity (IC). Methods: The Geant4 Application for the Tomographic Emission (GATE) Monte Carlo (MC) package was used, and reconstructed images were obtained by using the software for tomographic image reconstruction (STIR). The case study for the assessment of the information content was the General Electric (GE) Discovery-ST PET scanner. A thin-film plane source aluminum (Al) foil, coated with a thin layer of silica and with a 18F-fludeoxyglucose (FDG) bath distribution of 1 MBq was used. The influence of the (a) maximum likelihood estimation-ordered subsets-maximum a posteriori probability-one step late (MLE-OS-MAP-OSL) algorithm, using various subsets (1 to 21) and iterations (1 to 20) and (b) different scintillating crystals on PET scanner’s performance, was examined. The study was focused on the noise equivalent quanta (NEQ) and on the single index IC. Images of configurations by using different crystals were obtained after the commonly used 2-dimensional filtered back projection (FBP2D), 3-dimensional filtered back projection re-projection (FPB3DRP) and the (MLE)-OS-MAP-OSL algorithms. Results: Results shown that the images obtained with one subset and various iterations provided maximum NEQ values, however with a steep drop-off after 0.045 cycles/mm. The single index IC data were maximized for the range of 8–20 iterations and three subsets. The PET scanner configuration incorporating lutetium orthoaluminate perovskite (LuAP) crystals provided the highest NEQ values in 2D FBP for spatial frequencies higher than 0.028 cycles/mm. Bismuth germanium oxide (BGO) shows clear dominance against all other examined crystals across the spatial frequency range, in both 3D FBP and OS-MAP-OSL. The particular PET scanner provided optimum IC values using FBP3DRP and BGO crystals (2.4829 bits/mm2). Conclusions: The upper bound of the image information content of PET scanners can be fully characterized and further improved by investigating the imaging chain components through MC methods.
Collapse
|