Zeimpekis KG, Mercolli L, Conti M, Sari H, Rominger A, Rathke H. 90Y post-radioembolization clinical assessment with whole-body Biograph Vision Quadra PET/CT: image quality, tumor, liver and lung dosimetry. Eur J Nucl Med Mol Imaging 2024; 51:2100-2113. [PMID: 38347299 PMCID: PMC11139701 DOI: 10.1007/s00259-024-06650-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Accepted: 02/07/2024] [Indexed: 05/31/2024]
Abstract
PURPOSE Evaluation of 90Y liver radioembolization post-treatment clinical data using a whole-body Biograph Vision Quadra PET/CT to investigate the potential of protocol optimization in terms of scan time and dosimetry. METHODS 17 patients with hepatocellular carcinoma with median (IQR) injected activity 2393 (1348-3298) MBq were included. Pre-treatment dosimetry plan was based on 99mTc-MAA SPECT/CT with Simplicit90Y™ and post-treatment validation with Quadra using Simplicit90Y™ and HERMIA independently. Regarding the image analysis, mean and peak SNR, the coefficient of variation (COV) and lesion-to-background ratio (LBR) were evaluated. For the post-treatment dosimetry validation, the mean tumor, whole liver and lung absorbed dose evaluation was performed using Simplicit90Y and HERMES. Images were reconstructed with 20-, 15-, 10-, 5- and 1- min sinograms with 2, 4, 6 and 8 iterations. Wilcoxon signed rank test was used to show statistical significance (p < 0.05). RESULTS There was no difference of statistical significance between 20- and 5- min reconstructed times for the peak SNR, COV and LBR. In addition, there was no difference of statistical significance between 20- and 1- min reconstructed times for all dosimetry metrics. Lung dosimetry showed consistently lower values than the expected. Tumor absorbed dose based on Simplicit90Y™ was similar to the expected while HERMES consistently underestimated significantly the measured tumor absorbed dose. Finally, there was no difference of statistical significance between expected and measured tumor, whole liver and lung dose for all reconstruction times. CONCLUSION In this study we evaluated, in terms of image quality and dosimetry, whole-body PET clinical images of patients after having been treated with 90Y microspheres radioembolization for liver cancer. Compared to the 20-min standard scan, the simulated 5-min reconstructed images provided equal image peak SNR and noise behavior, while performing also similarly for post-treatment dosimetry of tumor, whole liver and lung absorbed doses.
Collapse
Affiliation(s)
- Konstantinos G Zeimpekis
- Department of Nuclear Medicine, Bern University Hospital, Inselspital, University of Bern, Freiburgstrasse 18, Bern, 3010, Switzerland.
| | - Lorenzo Mercolli
- Department of Nuclear Medicine, Bern University Hospital, Inselspital, University of Bern, Freiburgstrasse 18, Bern, 3010, Switzerland
| | - Maurizio Conti
- Molecular Imaging, Siemens Healthineers, Knoxville, TN, USA
| | - Hasan Sari
- Advanced Clinical Imaging Technology, Siemens Healthcare AG, Lausanne, Switzerland
| | - Axel Rominger
- Department of Nuclear Medicine, Bern University Hospital, Inselspital, University of Bern, Freiburgstrasse 18, Bern, 3010, Switzerland
| | - Hendrik Rathke
- Department of Nuclear Medicine, Bern University Hospital, Inselspital, University of Bern, Freiburgstrasse 18, Bern, 3010, Switzerland
| |
Collapse
|
2
|
Budzyńska A, Kubik A, Kacperski K, Pastusiak P, Kuć M, Piasecki P, Konior M, Gryziński M, Dziuk M, Iller E. PET/CT and SPECT/CT imaging of 90Y hepatic radioembolization at therapeutic and diagnostic activity levels: Anthropomorphic phantom study. PLoS One 2024; 19:e0271711. [PMID: 38421965 PMCID: PMC10903856 DOI: 10.1371/journal.pone.0271711] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Accepted: 02/15/2024] [Indexed: 03/02/2024] Open
Abstract
PURPOSE Prior to 90Y radioembolization procedure, a pretherapy simulation using 99mTc-MAA is performed. Alternatively, a small dosage of 90Y microspheres could be used. We aimed to assess the accuracy of lung shunt fraction (LSF) estimation in both high activity 90Y posttreatment and pretreatment scans with isotope activity of ~100 MBq, using different imaging techniques. Additionally, we assessed the feasibility of visualising hot and cold hepatic tumours in PET/CT and Bremsstrahlung SPECT/CT images. MATERIALS AND METHODS Anthropomorphic phantom including liver (with two spherical tumours) and lung inserts was filled with 90Y chloride to simulate an LSF of 9.8%. The total initial activity in the liver was 1451 MBq, including 19.4 MBq in the hot sphere. Nine measurement sessions including PET/CT, SPECT/CT, and planar images were acquired at activities in the whole phantom ranging from 1618 MBq down to 43 MBq. The visibility of the tumours was appraised based on independent observers' scores. Quantitatively, contrast-to-noise ratio (CNR) was calculated for both spheres in all images. RESULTS LSF estimation. For high activity in the phantom, PET reconstructions slightly underestimated the LSF; absolute difference was <1.5pp (percent point). For activity <100 MBq, the LSF was overestimated. Both SPECT and planar scintigraphy overestimated the LSF for all activities. Lesion visibility. For SPECT/CT, the cold tumour proved too small to be discernible (CNR <0.5) regardless of the 90Y activity in the liver, while hot sphere was visible for activity >200 MBq (CNR>4). For PET/CT, the cold tumour was only visible with the highest 90Y activity (CNR>4), whereas the hot one was seen for activity >100 MBq (CNR>5). CONCLUSIONS PET/CT may accurately estimate the LSF in a 90Y posttreatment procedure. However, at low activities of about 100 MBq it seems to provide unreliable estimations. PET imaging provided better visualisation of both hot and cold tumours.
Collapse
Affiliation(s)
- Anna Budzyńska
- Department of Nuclear Medicine, Military Institute of Medicine - National Research Institute, Warsaw, Poland
- Affidea Mazovian PET-CT Medical Centre, Warsaw, Poland
| | - Agata Kubik
- Department of Nuclear Medicine, Military Institute of Medicine - National Research Institute, Warsaw, Poland
| | - Krzysztof Kacperski
- Department of Nuclear Medicine, Military Institute of Medicine - National Research Institute, Warsaw, Poland
- National Centre for Nuclear Research, Particle Acceleration Physics and Technology Division (TJ1), Otwock—Świerk, Poland
| | - Patrycja Pastusiak
- Department of Nuclear Medicine, Military Institute of Medicine - National Research Institute, Warsaw, Poland
| | - Michał Kuć
- National Centre for Nuclear Research, Radiological Metrology and Biomedical Physics Division (H2), Otwock—Świerk, Poland
| | - Piotr Piasecki
- Department of Interventional Radiology, Military Institute of Medicine - National Research Institute, Warsaw, Poland
| | - Marcin Konior
- National Centre for Nuclear Research, Radioisotope Centre POLATOM, Otwock - Świerk, Poland
| | - Michał Gryziński
- National Centre for Nuclear Research, Radiological Metrology and Biomedical Physics Division (H2), Otwock—Świerk, Poland
| | - Mirosław Dziuk
- Department of Nuclear Medicine, Military Institute of Medicine - National Research Institute, Warsaw, Poland
- Affidea Mazovian PET-CT Medical Centre, Warsaw, Poland
| | - Edward Iller
- National Centre for Nuclear Research, Radioisotope Centre POLATOM, Otwock - Świerk, Poland
| |
Collapse
|
3
|
Mercolli L, Zeimpekis K, Prenosil GA, Sari H, Rathke HG, Rominger A, Shi K. Phantom study for 90Y liver radioembolization dosimetry with a long axial field-of-view PET/CT. Phys Med 2024; 118:103296. [PMID: 38281409 DOI: 10.1016/j.ejmp.2024.103296] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/30/2023] [Revised: 11/20/2023] [Accepted: 01/23/2024] [Indexed: 01/30/2024] Open
Abstract
PURPOSE The physical properties of yttrium-90 (90Y) allow for imaging with positron emission tomography/computed tomography (PET/CT). The increased sensitivity of long axial field-of-view (LAFOV) PET/CT scanners possibly allows to overcome the small branching ratio for positron production from 90Y decays and to improve for the post-treatment dosimetry of 90Y of selective internal radiation therapy. METHODS For the challenging case of an image quality body phantom, we compare a full Monte Carlo (MC) dose calculation with the results from the two commercial software packages Simplicit90Y and Hermes. The voxel dosimetry module of Hermes relies on the 90Y images taken with a LAFOV PET/CT, while the MC and Simplicit90Y dose calculations are image independent. RESULTS The resulting doses from the MC calculation and Simplicit90Y agree well within the error margins. The image-based dose calculation with Hermes, however, consistently underestimates the dose. This is due to the mismatch of the activity distribution in the PET images and the size of the volume of interest. We found that only for the smallest phantom sphere there is a statistically significant dependence of the Hermes dose on the image reconstruction parameters and scan time. CONCLUSION Our study shows that Simplicit90Y's local deposition model can provide a reliable dose estimate. On the other hand, the image based dose calculation suffers from the suboptimal reconstruction of the 90Y distribution in small structures.
Collapse
Affiliation(s)
- Lorenzo Mercolli
- Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 18, CH-3010 Bern, Switzerland.
| | - Konstantinos Zeimpekis
- Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 18, CH-3010 Bern, Switzerland
| | - George A Prenosil
- Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 18, CH-3010 Bern, Switzerland
| | - Hasan Sari
- Advanced Clinical Imaging Technology, Siemens Healthcare AG, Lausanne, Switzerland
| | - Hendrik G Rathke
- Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 18, CH-3010 Bern, Switzerland
| | - Axel Rominger
- Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 18, CH-3010 Bern, Switzerland
| | - Kunagyu Shi
- Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 18, CH-3010 Bern, Switzerland
| |
Collapse
|
4
|
Calderón E, Schmidt FP, Lan W, Castaneda-Vega S, Brendlin AS, Trautwein NF, Dittmann H, la Fougère C, Kiefer LS. Image Quality and Quantitative PET Parameters of Low-Dose [ 18F]FDG PET in a Long Axial Field-of-View PET/CT Scanner. Diagnostics (Basel) 2023; 13:3240. [PMID: 37892061 PMCID: PMC10606613 DOI: 10.3390/diagnostics13203240] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Revised: 10/15/2023] [Accepted: 10/15/2023] [Indexed: 10/29/2023] Open
Abstract
PET/CT scanners with a long axial field-of-view (LAFOV) provide increased sensitivity, enabling the adjustment of imaging parameters by reducing the injected activity or shortening the acquisition time. This study aimed to evaluate the limitations of reduced [18F]FDG activity doses on image quality, lesion detectability, and the quantification of lesion uptake in the Biograph Vision Quadra, as well as to assess the benefits of the recently introduced ultra-high sensitivity mode in a clinical setting. A number of 26 patients who underwent [18F]FDG-PET/CT (3.0 MBq/kg, 5 min scan time) were included in this analysis. The PET raw data was rebinned for shorter frame durations to simulate 5 min scans with lower activities in the high sensitivity (HS) and ultra-high sensitivity (UHS) modes. Image quality, noise, and lesion detectability (n = 82) were assessed using a 5-point Likert scale. The coefficient of variation (CoV), signal-to-noise ratio (SNR), tumor-to-background ratio (TBR), and standardized uptake values (SUV) including SUVmean, SUVmax, and SUVpeak were evaluated. Subjective image ratings were generally superior in UHS compared to the HS mode. At 0.5 MBq/kg, lesion detectability decreased to 95% (HS) and to 98% (UHS). SNR was comparable at 1.0 MBq/kg in HS (5.7 ± 0.6) and 0.5 MBq/kg in UHS (5.5 ± 0.5). With lower doses, there were negligible reductions in SUVmean and SUVpeak, whereas SUVmax increased steadily. Reducing the [18F]FDG activity to 1.0 MBq/kg (HS/UHS) in a LAFOV PET/CT provides diagnostic image quality without statistically significant changes in the uptake parameters. The UHS mode improves image quality, noise, and lesion detectability compared to the HS mode.
Collapse
Affiliation(s)
- Eduardo Calderón
- Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, 72076 Tuebingen, Germany; (E.C.); (F.P.S.); (W.L.); (S.C.-V.); (N.F.T.); (H.D.); (C.l.F.)
| | - Fabian P. Schmidt
- Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, 72076 Tuebingen, Germany; (E.C.); (F.P.S.); (W.L.); (S.C.-V.); (N.F.T.); (H.D.); (C.l.F.)
- Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard-Karls University Tuebingen, 72076 Tuebingen, Germany
| | - Wenhong Lan
- Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, 72076 Tuebingen, Germany; (E.C.); (F.P.S.); (W.L.); (S.C.-V.); (N.F.T.); (H.D.); (C.l.F.)
| | - Salvador Castaneda-Vega
- Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, 72076 Tuebingen, Germany; (E.C.); (F.P.S.); (W.L.); (S.C.-V.); (N.F.T.); (H.D.); (C.l.F.)
- Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard-Karls University Tuebingen, 72076 Tuebingen, Germany
| | - Andreas S. Brendlin
- Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, 72076 Tuebingen, Germany;
| | - Nils F. Trautwein
- Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, 72076 Tuebingen, Germany; (E.C.); (F.P.S.); (W.L.); (S.C.-V.); (N.F.T.); (H.D.); (C.l.F.)
| | - Helmut Dittmann
- Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, 72076 Tuebingen, Germany; (E.C.); (F.P.S.); (W.L.); (S.C.-V.); (N.F.T.); (H.D.); (C.l.F.)
| | - Christian la Fougère
- Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, 72076 Tuebingen, Germany; (E.C.); (F.P.S.); (W.L.); (S.C.-V.); (N.F.T.); (H.D.); (C.l.F.)
- Cluster of Excellence iFIT (EXC 2180) “Image Guided and Functionally Instructed Tumor Therapies”, University of Tuebingen, 72074 Tuebingen, Germany
- German Cancer Consortium (DKTK), Partner Site Tuebingen, 72074 Tuebingen, Germany
| | - Lena Sophie Kiefer
- Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, 72076 Tuebingen, Germany; (E.C.); (F.P.S.); (W.L.); (S.C.-V.); (N.F.T.); (H.D.); (C.l.F.)
| |
Collapse
|
5
|
D’Arienzo M, Mezzenga E, Capotosti A, Bagni O, Filippi L, Capogni M, Indovina L, Sarnelli A. The Importance of Uncertainty Analysis and Traceable Measurements in Routine Quantitative 90Y-PET Molecular Radiotherapy: A Multicenter Experience. Pharmaceuticals (Basel) 2023; 16:1142. [PMID: 37631057 PMCID: PMC10459699 DOI: 10.3390/ph16081142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2023] [Revised: 08/01/2023] [Accepted: 08/03/2023] [Indexed: 08/27/2023] Open
Abstract
Molecular Radiation Therapy (MRT) is a valid therapeutic option for a wide range of malignancies, such as neuroendocrine tumors and liver cancers. In its practice, it is generally acknowledged that there is a need to evaluate the influence of different factors affecting the accuracy of dose estimates and to define the actions necessary to maintain treatment uncertainties at acceptable levels. The present study addresses the problem of uncertainty propagation in 90Y-PET quantification. We assessed the quantitative accuracy in reference conditions of three PET scanners (namely, Siemens Biograph mCT, Siemens Biograph mCT flow, and GE Discovery DST) available at three different Italian Nuclear Medicine centers. Specific aspects of uncertainty within the quantification chain have been addressed, including the uncertainty in the calibration procedure. A framework based on the Guide to the Expression of Uncertainty in Measurement (GUM) approach is proposed for modeling the uncertainty in the quantification processes, and ultimately, an estimation of the uncertainty achievable in clinical conditions is reported.
Collapse
Affiliation(s)
- Marco D’Arienzo
- Medical Physics Section, ASL Roma 6, Borgo Garibaldi 12, 00041 Rome, Italy;
- UniCamillus International Medical University, 00131 Rome, Italy
| | - Emilio Mezzenga
- Medical Physics Unit, IRCCS Istituto Romagnolo per lo Studio dei Tumori (IRST) “Dino Amadori”, 47014 Meldola, Italy; (E.M.); (A.S.)
| | - Amedeo Capotosti
- Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Roma, Italy;
| | - Oreste Bagni
- Nuclear Medicine Department, Santa Maria Goretti Hospital, 04100 Latina, Italy; (O.B.); (L.F.)
| | - Luca Filippi
- Nuclear Medicine Department, Santa Maria Goretti Hospital, 04100 Latina, Italy; (O.B.); (L.F.)
| | - Marco Capogni
- ENEA, Italian National Institute of Ionizing Radiation Metrology, Via Anguillarese 301, 00123 Rome, Italy;
| | - Luca Indovina
- Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Roma, Italy;
| | - Anna Sarnelli
- Medical Physics Unit, IRCCS Istituto Romagnolo per lo Studio dei Tumori (IRST) “Dino Amadori”, 47014 Meldola, Italy; (E.M.); (A.S.)
| |
Collapse
|
6
|
Kersting D, Jentzen W, Jeromin D, Mavroeidi IA, Conti M, Büther F, Herrmann K, Rischpler C, Hamacher R, Fendler WP, Seifert R, Costa PF. Lesion Quantification Accuracy of Digital 90Y PET Imaging in the Context of Dosimetry in Systemic Fibroblast Activation Protein Inhibitor Radionuclide Therapy. J Nucl Med 2023; 64:329-336. [PMID: 35981898 PMCID: PMC9902858 DOI: 10.2967/jnumed.122.264338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2022] [Revised: 08/13/2022] [Accepted: 08/13/2022] [Indexed: 02/04/2023] Open
Abstract
Therapy with 90Y-labeled fibroblast activation protein inhibitors (90Y-FAPIs) was recently introduced as a novel treatment concept for patients with solid tumors. Lesion and organ-at-risk dosimetry is part of assessing treatment efficacy and safety and requires reliable quantification of tissue uptake. As 90Y quantification is limited by the low internal positron-electron pair conversion rate, the increased effective sensitivity of digital silicon photomultiplier-based PET/CT systems might increase quantification accuracy and, consequently, allow for dosimetry in 90Y-FAPI therapy. The aim of this study was to explore the conditions for reliable lesion image quantification in 90Y-FAPI radionuclide therapy using a digital PET/CT system. Methods: Two tumor phantoms were filled with 90Y solution using different sphere activity concentrations and a constant signal-to-background ratio of 40. The minimum detectable activity concentration was determined, and its dependence on acquisition time (15 vs. 30 min per bed position) and smoothing levels (all-pass vs. 5-mm gaussian filter) was investigated. Quantification accuracy was evaluated at various activity concentrations to estimate the minimum quantifiable activity concentration using contour-based and oversized volume-of-interest-based quantification approaches. A ±20% deviation range between image-derived and true activity concentrations was regarded as acceptable. Tumor dosimetry for 3 patients treated with 90Y-FAPI is presented to project the phantom results to clinical scenarios. Results: For a lesion size of 40 mm and a clinical acquisition time of 15 min, both minimum detectable and minimum quantifiable activity concentrations were 0.12 MBq/mL. For lesion sizes of greater than or equal to 30 mm, accurate quantification was feasible for detectable lesions. Only for the smallest 10-mm sphere, the minimum detectable and minimum quantifiable activity concentrations differ substantially (0.43 vs. 1.97 MBq/mL). No notable differences between the 2 quantification approaches were observed. For the investigated tumors, absorbed dose estimates with reliable accuracy were achievable. Conclusion: For lesion sizes and activity concentrations that are expected to be observed in patients treated with 90Y-FAPI, quantification with reasonable accuracy is possible. Further dosimetry studies are needed to thoroughly investigate the efficacy and safety of 90Y-FAPI therapy.
Collapse
Affiliation(s)
- David Kersting
- Department of Nuclear Medicine, West German Cancer Center (WTZ), University Hospital Essen, University of Duisburg-Essen, Essen, Germany; .,German Cancer Consortium (DKTK), Partner Site University Hospital Essen, Essen, Germany
| | - Walter Jentzen
- Department of Nuclear Medicine, West German Cancer Center (WTZ), University Hospital Essen, University of Duisburg-Essen, Essen, Germany;,German Cancer Consortium (DKTK), Partner Site University Hospital Essen, Essen, Germany
| | - Daniel Jeromin
- Department of Nuclear Medicine, West German Cancer Center (WTZ), University Hospital Essen, University of Duisburg-Essen, Essen, Germany;,German Cancer Consortium (DKTK), Partner Site University Hospital Essen, Essen, Germany
| | - Ilektra-Antonia Mavroeidi
- German Cancer Consortium (DKTK), Partner Site University Hospital Essen, Essen, Germany;,Department of Medical Oncology, West German Cancer Center (WTZ), University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Maurizio Conti
- Siemens Medical Solutions USA, Inc., Knoxville, Tennessee; and
| | - Florian Büther
- Department of Nuclear Medicine, University Hospital Muenster, University of Muenster, Muenster, Germany
| | - Ken Herrmann
- Department of Nuclear Medicine, West German Cancer Center (WTZ), University Hospital Essen, University of Duisburg-Essen, Essen, Germany;,German Cancer Consortium (DKTK), Partner Site University Hospital Essen, Essen, Germany
| | - Christoph Rischpler
- Department of Nuclear Medicine, West German Cancer Center (WTZ), University Hospital Essen, University of Duisburg-Essen, Essen, Germany;,German Cancer Consortium (DKTK), Partner Site University Hospital Essen, Essen, Germany
| | - Rainer Hamacher
- German Cancer Consortium (DKTK), Partner Site University Hospital Essen, Essen, Germany;,Department of Medical Oncology, West German Cancer Center (WTZ), University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Wolfgang P. Fendler
- Department of Nuclear Medicine, West German Cancer Center (WTZ), University Hospital Essen, University of Duisburg-Essen, Essen, Germany;,German Cancer Consortium (DKTK), Partner Site University Hospital Essen, Essen, Germany
| | - Robert Seifert
- Department of Nuclear Medicine, West German Cancer Center (WTZ), University Hospital Essen, University of Duisburg-Essen, Essen, Germany;,German Cancer Consortium (DKTK), Partner Site University Hospital Essen, Essen, Germany;,Department of Nuclear Medicine, University Hospital Muenster, University of Muenster, Muenster, Germany
| | - Pedro Fragoso Costa
- Department of Nuclear Medicine, West German Cancer Center (WTZ), University Hospital Essen, University of Duisburg-Essen, Essen, Germany;,German Cancer Consortium (DKTK), Partner Site University Hospital Essen, Essen, Germany
| |
Collapse
|
7
|
Phantom-based evaluation of yttrium-90 datasets using biograph vision quadra. Eur J Nucl Med Mol Imaging 2023; 50:1168-1182. [PMID: 36504278 PMCID: PMC9931793 DOI: 10.1007/s00259-022-06074-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2022] [Accepted: 12/04/2022] [Indexed: 12/14/2022]
Abstract
PURPOSE The image quality characteristics of two NEMA phantoms with yttrium-90 (90Y) were evaluated on a long axial field-of-view (AFOV) PET/CT. The purpose was to identify the optimized reconstruction setup for the imaging of patients with hepatocellular carcinoma after 90Y radioembolization. METHODS Two NEMA phantoms were used, where one had a 1:10 sphere to background activity concentration ratio and the second had cold background. Reconstruction parameters used are as follows: iterations 2 to 8, Gaussian filter 2- to 6-mm full-width-at-half-maximum, reconstruction matrices 440 × 440 and 220 × 220, high sensitivity (HS), and ultra-high sensitivity (UHS) modes. 50-, 40-, 30-, 20-, 10-, and 5-min acquisitions were reconstructed. The measurements included recovery coefficients (RC), signal-to-noise ratio (SNR), background variability, and lung error which measures the residual error in the corrections. Patient data were reconstructed with 20-, 10-, 5-, and 1-min time frames and evaluated in terms of SNR. RESULTS The RC for the hot phantom was 0.36, 0.45, 0.53, 0.63, 0.68, and 0.84 for the spheres with diameters of 10, 13, 17, 22, 28, and 37 mm, respectively, for UHS 2 iterations, a 220 × 220 matrix, and 50-min acquisition. The RC values did not differ with acquisition times down to 20 min. The SNR was the highest for 2 iterations, measured 11.7, 16.6, 17.6, 19.4, 21.9, and 27.7 while the background variability was the lowest (27.59, 27.08, 27.36, 26.44, 30.11, and 33.51%). The lung error was 18%. For the patient dataset, the SNR was 19%, 20%, 24%, and 31% higher for 2 iterations compared to 4 iterations for 20-, 10-, 5-, and 1-min time frames, respectively. CONCLUSIONS This study evaluates the NEMA image quality of a long AFOV PET/CT scanner with 90Y. It provides high RC for the smallest sphere compared to other standard AFOV scanners at shorter scan times. The maximum patient SNR was for 2 iterations, 20 min, while 5 min delivers images with acceptable SNR.
Collapse
|
8
|
Millardet M, Moussaoui S, Idier J, Mateus D, Conti M, Bailly C, Stute S, Carlier T. A Multiobjective Comparative Analysis of Reconstruction Algorithms in the Context of Low-Statistics 90Y-PET Imaging. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2022. [DOI: 10.1109/trpms.2021.3126951] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Affiliation(s)
- Mael Millardet
- LS2N, CNRS UMR 6004, École centrale de Nantes, Nantes, France
| | - Said Moussaoui
- LS2N, CNRS UMR 6004, École centrale de Nantes, Nantes, France
| | - Jerome Idier
- LS2N, CNRS UMR 6004, École centrale de Nantes, Nantes, France
| | - Diana Mateus
- LS2N, CNRS UMR 6004, École centrale de Nantes, Nantes, France
| | - Maurizio Conti
- Physics Research Group, Siemens Medical Solution USA Inc., Knoxville, TN, USA
| | | | | | | |
Collapse
|
9
|
Nichols AL. Status of the decay data for medical radionuclides: existing and potential diagnostic γ emitters, diagnostic β + emitters and therapeutic radioisotopes. RADIOCHIM ACTA 2022. [DOI: 10.1515/ract-2022-0004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Abstract
Recommended half-lives and specific well-defined emission energies and absolute emission probabilities are important input parameters that should be well-defined to assist in ensuring the diagnostic and therapeutic efficacy of individual radionuclides when applied in the field of nuclear medicine. Bearing in mind the nature of these requirements, approximately one hundred radionuclides have been considered and re-assessed as to whether their decay data are either adequately quantified, or require further in-depth measurements to improve their existing status and merit full re-evaluations of their decay schemes. The primary aim of such a review is to provide sufficient information on the existing and future requirements for such atomic and nuclear data.
Collapse
Affiliation(s)
- Alan L. Nichols
- Department of Physics , University of Surrey , Guildford , GU2 7XH , UK
- Manipal Academy of Higher Education, Manipal, Karnataka 576104 , India
| |
Collapse
|
10
|
Graves SA, Martin M, Tiwari A, Merrick MJ, Sunderland JJ. SIR-Spheres activity measurements reveal systematic miscalibration. J Nucl Med 2022; 63:1131-1135. [PMID: 34992155 DOI: 10.2967/jnumed.121.262650] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Accepted: 11/16/2021] [Indexed: 11/16/2022] Open
Abstract
Purpose: Accurate dosimetry-guided radiopharmaceutical therapy fundamentally relies on knowledge of the quantity of radioactivity administered to patients. The purpose of this work was to perform an independent and NIST-traceable activity measurement of 90Y SIR-Spheres®. Methods: Gamma spectroscopic measurements of the 90Y internal pair production decay mode were made using a high-purity germanium detector. Un-modified patient SIR-Spheres® vials were placed within a high-density polyethylene source holder positioned at a distance of 210 cm from the detector, with acquisition durations of 3 - 6 hours. Measured annihilation radiation detection rates were corrected for radioactive decay during acquisition, dead time, source attenuation, and source geometry effects. Detection efficiency was determined by two independent and NIST-traceable methods. Resulting 90Y activity measurements were compared against the manufacturer activity calibration. Results: Measured SIR-Sphere® vials (n = 5) were found to contain more activity than specified by the manufacturer calibration - on average the ratio of measured activity to calibrated was 1.233 ± 0.030. Activity measurements made using two distinct efficiency calibration methods were found to agree within 1%. Uncertainty in individual measurements was dominated by counting statistical uncertainty (~2.5%), uncertainty in the internal pair production branching ratio of 90Y (1.5%), and efficiency calibration (1.2% - 1.9%). Conclusion: The primary SIR-Spheres® activity calibration appears to be a significant underestimate of true activity. This mis-calibration has likely been consistent for as long as the SIR-Sphere® product has been available. This finding should be independently verified, and steps should be taken by the manufacturer to establish an accurate and traceable activity standard.
Collapse
|
11
|
Labour J, Boissard P, Baudier T, Khayi F, Kryza D, Durebex PV, Martino SPD, Mognetti T, Sarrut D, Badel JN. Yttrium-90 quantitative phantom study using digital photon counting PET. EJNMMI Phys 2021; 8:56. [PMID: 34318383 PMCID: PMC8316557 DOI: 10.1186/s40658-021-00402-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2021] [Accepted: 06/23/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND PET imaging of 90Y-microsphere distribution following radioembolisation is challenging due to the count-starved statistics from the low branching ratio of e+/e- pair production during 90Y decay. PET systems using silicon photo-multipliers have shown better 90Y image quality compared to conventional photo-multiplier tubes. The main goal of the present study was to evaluate reconstruction parameters for different phantom configurations and varying listmode acquisition lengths to improve quantitative accuracy in 90Y dosimetry, using digital photon counting PET/CT. METHODS Quantitative PET and dosimetry accuracy were evaluated using two uniform cylindrical phantoms specific for PET calibration validation. A third body phantom with a 9:1 hot sphere-to-background ratio was scanned at different activity concentrations of 90Y. Reconstructions were performed using OSEM algorithm with varying parameters. Time-of-flight and point-spread function modellings were included in all reconstructions. Absorbed dose calculations were carried out using voxel S-values convolution and were compared to reference Monte Carlo simulations. Dose-volume histograms and root-mean-square deviations were used to evaluate reconstruction parameter sets. Using listmode data, phantom and patient datasets were rebinned into various lengths of time to assess the influence of count statistics on the calculation of absorbed dose. Comparisons between the local energy deposition method and the absorbed dose calculations were performed. RESULTS Using a 2-mm full width at half maximum post-reconstruction Gaussian filter, the dosimetric accuracy was found to be similar to that found with no filter applied but also reduced noise. Larger filter sizes should not be used. An acquisition length of more than 10 min/bed reduces image noise but has no significant impact in the quantification of phantom or patient data for the digital photon counting PET. 3 iterations with 10 subsets were found suitable for large spheres whereas 1 iteration with 30 subsets could improve dosimetry for smaller spheres. CONCLUSION The best choice of the combination of iterations and subsets depends on the size of the spheres. However, one should be careful on this choice, depending on the imaging conditions and setup. This study can be useful in this choice for future studies for more accurate 90Y post-dosimetry using a digital photon counting PET/CT.
Collapse
Affiliation(s)
- Joey Labour
- CREATIS; CNRS UMR 5220; INSERM U 1044; Université de Lyon; INSA-Lyon; Université Lyon 1, Lyon, France
- Centre de lutte contre le cancer Léon Bérard, Lyon, France
| | | | - Thomas Baudier
- CREATIS; CNRS UMR 5220; INSERM U 1044; Université de Lyon; INSA-Lyon; Université Lyon 1, Lyon, France
- Centre de lutte contre le cancer Léon Bérard, Lyon, France
| | - Fouzi Khayi
- Centre de lutte contre le cancer Léon Bérard, Lyon, France
| | - David Kryza
- Centre de lutte contre le cancer Léon Bérard, Lyon, France
- Hospices Civils de Lyon; Université de Lyon; Université Claude Bernard Lyon 1; LAGEPP UMR 5007 CNRS, Lyon, France
| | | | | | | | - David Sarrut
- CREATIS; CNRS UMR 5220; INSERM U 1044; Université de Lyon; INSA-Lyon; Université Lyon 1, Lyon, France
- Centre de lutte contre le cancer Léon Bérard, Lyon, France
| | - Jean-Noël Badel
- CREATIS; CNRS UMR 5220; INSERM U 1044; Université de Lyon; INSA-Lyon; Université Lyon 1, Lyon, France
- Centre de lutte contre le cancer Léon Bérard, Lyon, France
| |
Collapse
|
12
|
Kubik A, Budzyńska A, Kacperski K, Maciak M, Kuć M, Piasecki P, Wiliński M, Konior M, Dziuk M, Iller E. Evaluation of qualitative and quantitative data of Y-90 imaging in SPECT/CT and PET/CT phantom studies. PLoS One 2021; 16:e0246848. [PMID: 33566845 PMCID: PMC7875374 DOI: 10.1371/journal.pone.0246848] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Accepted: 01/26/2021] [Indexed: 01/06/2023] Open
Abstract
Introduction We aimed to assess the feasibility of SPECT and PET Y-90 imaging, and to compare these modalities by visualizing hot and cold foci in phantoms for varying isotope concentrations. Materials and methods The data was acquired from the Jaszczak and NEMA phantoms. In the Jaszczak phantom Y-90 concentrations of 0.1 MBq/ml and 0.2 MBq/ml were used, while higher concentrations, up to 1.0 MBq/ml, were simulated by acquisition time extension with respect to the standard clinical protocol of 30 sec/projection for SPECT and 30 min/bed position for PET imaging. For NEMA phantom, the hot foci had concentrations of about 4 MB/ml and the background 0.1 or 0.0 MBq/ml. All of the acquired data was analysed both qualitatively and quantitatively. Qualitative assessment was conducted by six observers asked to identify the number of visible cold or hot foci. Inter-observer agreement was assessed. Quantitative analysis included calculations of contrast and contrast-to-noise ratio (CNR), and comparisons with the qualitative results. Results For SPECT data up to two cold foci were discernible, while for PET four foci were visible. We have shown that CNR (with Rose criterion) is a good measure of foci visibility for both modalities. We also found good concordance of qualitative results for the Jaszczak phantom studies between the observers (corresponding Krippendorf’s alpha coefficients of 0.76 to 0.84). In the NEMA phantom without background activity all foci were visible in SPECT/CT images. With isotope in the background, 5 of 6 spheres were discernible (CNR of 3.0 for the smallest foci). For PET studies all hot spheres were visible, regardless of the background activity. Conclusions PET Y-90 imaging provided better results than Bremsstrahlung based SPECT imaging. This indicates that PET/CT might become the method of choice in Y-90 post radioembolization imaging for visualisation of both necrotic and hot lesions in the liver.
Collapse
Affiliation(s)
- Agata Kubik
- Department of Nuclear Medicine, Military Institute of Medicine, Warsaw, Poland
- * E-mail:
| | - Anna Budzyńska
- Department of Nuclear Medicine, Military Institute of Medicine, Warsaw, Poland
- Affidea Mazovian PET/CT Medical Centre, Warsaw, Poland
| | - Krzysztof Kacperski
- Department of Nuclear Medicine, Military Institute of Medicine, Warsaw, Poland
- Particle Acceleration Physics and Technology Division (TJ1), National Centre for Nuclear Research, Otwock—Świerk, Poland
| | - Maciej Maciak
- Radiological Metrology and Biomedical Physics Division (H2), National Centre for Nuclear Research, Otwock—Świerk, Poland
| | - Michał Kuć
- Radiological Metrology and Biomedical Physics Division (H2), National Centre for Nuclear Research, Otwock—Świerk, Poland
| | - Piotr Piasecki
- Department of Interventional Radiology, Military Institute of Medicine, Warsaw, Poland
| | - Maciej Wiliński
- Radiological Metrology and Biomedical Physics Division (H2), National Centre for Nuclear Research, Otwock—Świerk, Poland
| | - Marcin Konior
- National Centre for Nuclear Research, Radioisotope Centre POLATOM, Otwock—Świerk, Poland
| | - Mirosław Dziuk
- Department of Nuclear Medicine, Military Institute of Medicine, Warsaw, Poland
- Affidea Mazovian PET/CT Medical Centre, Warsaw, Poland
| | - Edward Iller
- National Centre for Nuclear Research, Radioisotope Centre POLATOM, Otwock—Świerk, Poland
| |
Collapse
|
13
|
Hou X, Ma H, Esquinas PL, Uribe C, Tolhurst S, Bénard F, Liu D, Rahmim A, Celler A. Impact of image reconstruction method on dose distributions derived from 90Y PET images: phantom and liver radioembolization patient studies. Phys Med Biol 2020; 65:215022. [PMID: 33245057 DOI: 10.1088/1361-6560/aba8b5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
PET images acquired after liver 90Y radioembolization therapies are typically very noisy, which significantly challenges both visualization and quantification of activity distributions. To improve their noise characteristics, regularized iterative reconstruction algorithms such as block sequential regularized expectation maximization (Q.Clear for GE Healthcare, USA) have been proposed. In this study, we aimed to investigate the effects which different reconstruction algorithms may have on patient images, with reconstruction parameters initially narrowed down using phantom studies. Moreover, we evaluated the impact of these reconstruction methods on voxel-based dose distribution in phantom and patient studies (lesions and healthy livers). The International Electrotechnical Commission (IEC)/NEMA phantom, containing six spheres, was filled with 90Y and imaged using a GE Discovery 690 PET/CT scanner with time-of-flight enabled. The images were reconstructed using Q.Clear (with β parameter ranging from 0 to 8000) and ordered subsets expectation maximization. The image quality and quantification accuracy were evaluated by computing the hot ([Formula: see text]) and cold ([Formula: see text]) contrast recovery coefficients, background variability (BV) and activity bias. Next, dose distributions and dose volume histograms were generated using MIM® software's SurePlan LiverY90 toolbox. Subsequently, parameters optimized in these phantom studies were applied to five patient datasets. Dose parameters, such as Dmax, Dmean, D70, and V100Gy, were estimated, and their variability for different reconstruction methods was investigated. Based on phantom studies, the β parameter values optimized for image quality and quantification accuracy were 2500 and 300, respectively. When all investigated reconstructions were applied to patient studies, Dmean, D50, D70, and V100Gy showed coefficients of variation below 8%; whereas the variability of Dmax was up to 30% for both phantom and patient images. Although β = 300-1000 would provide accurate activity quantification for a region of interest, when considering activity/dose voxelized distribution, higher β value (e.g. 4000-5000) would provide the greatest accuracy for dose distributions. In this 90Y radioembolization PET/CT study, the β parameter in regularized iterative (Q.Clear) reconstruction was investigated for image quality, accurate quantification and dose distributions based on phantom experiments and then applied to patient studies. Our results indicate that more accurate dose distribution can be achieved from smoother PET images, reconstructed with larger β values than those yielding the best activity quantifications but noisy images. Most importantly, these results suggest that quantitative measures, which are commonly used in clinics, such as SUVmax or SUVpeak( equivalent of Dmax), should not be employed for 90Y PET images, since their values would highly depend on the image reconstruction.
Collapse
Affiliation(s)
- Xinchi Hou
- Department of Radiology, University of British Columbia, Vancouver, Canada
| | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Kossert K, Mougeot X. Improved activity standardization of 90Sr/ 90Y by means of liquid scintillation counting. Appl Radiat Isot 2020; 168:109478. [PMID: 33097378 DOI: 10.1016/j.apradiso.2020.109478] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Revised: 10/09/2020] [Accepted: 10/15/2020] [Indexed: 11/20/2022]
Abstract
Radioactive strontium isotopes play an important role in environmental radioactivity. Reliable activity standards are required in order to validate radioanalytical techniques and related measurements. In this paper, improved methods for the primary activity standardization of 90Sr/90Y based on liquid scintillation counting are presented. To this end, two methods were used: the CIEMAT/NIST efficiency tracing technique with 3H as a tracer and the triple-to-double coincidence ratio method. Non-negligible discrepancies between the two methods were found when applying existing analysis techniques. A detailed study was carried out to identify and eliminate the causes of these discrepancies. Eventually, excellent agreement between the two methods was obtained. This required advanced beta spectrum calculations which were carried out with a specific version of the BetaShape program taking the atomic exchange effect into account. In addition, it was found that the quench-indicating parameters determined in commercial liquid scintillation counters are biased, which can cause significant problems for the CIEMAT/NIST efficiency tracing method. The effect depends on the counting rate and can be explained by a superposition of the LS spectra generated by 90Sr/90Y and the external standard source.
Collapse
Affiliation(s)
- Karsten Kossert
- Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116, Braunschweig, Germany.
| | - Xavier Mougeot
- CEA, LIST, Laboratoire National Henri Becquerel, F-91191, Gif-sur-Yvette, France
| |
Collapse
|