Nakanishi K, Fujita N, Abe S, Nishii R, Kato K. A simple method to shorten the apparent dead time in the dosimetry of Lu-177 for targeted radionuclide therapy using a gamma camera. Phys Med 2024; 119:103298. [PMID: 38309102 DOI: 10.1016/j.ejmp.2024.103298] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Revised: 12/04/2023] [Accepted: 01/23/2024] [Indexed: 02/05/2024] Open
Abstract
BACKGROUND The dead-time loss reportedly degrades the accuracy of dosimetry using a gamma camera for targeted radionuclide therapy with Lu-177; therefore, the dead-time loss needs to be corrected. However, the correction is challenging. In this study, we propose a novel and simple method to shorten the apparent dead time rather than correcting it through experiments and Monte Carlo simulations. METHODS An energy window of 208 keV ± 10 % is generally used for the imaging of Lu-177. Lower-energy gamma photons and X-rays of Lu-177 do not contribute to image formation but lead to dead-time losses. In our proposed method, a thin lead sheet was used to shield gamma photons and X-rays with energies lower than 208 keV, while detecting 208 keV gamma photons that penetrated the thin sheet. We measured and simulated the energy spectra and count rate characteristics of a clinical gamma camera system using a cylindrical phantom filled with a Lu-177 solution. Lead sheets of 1.0- and 0.5-mm thicknesses were used as thin shields, and the dead-time losses in tumour imaging with consumed Lu-177 were simulated. RESULTS The apparent dead times with lead sheets of 1.0- and 0.5-mm thicknesses and without a lead sheet were 1.7, 1.9, and 5.8 µs for an energy window of 208 keV ± 10 %, respectively. The dead-time losses could be reduced from 10 % to 1.3 % using the 1.0-mm thick lead sheet in the simulated imaging of tumour. CONCLUSION Our method is promising in clinical situations and studies on Lu-177 dosimetry for tumours.
Collapse
Affiliation(s)
- Kohei Nakanishi
- Functional Medical Imaging, Biomedical Imaging Sciences, Division of Advanced Information Health Sciences, Department of Integrated Health Sciences, Nagoya University Graduate School of Medicine, Nagoya, Japan.
| | - Naotoshi Fujita
- Department of Radiological Technology, Nagoya University Hospital, Nagoya, Japan
| | - Shinji Abe
- Department of Radiological Technology, Nagoya University Hospital, Nagoya, Japan
| | - Ryuichi Nishii
- Medical Imaging Engineering, Biomedical Imaging Sciences, Division of Advanced Information Health Sciences, Department of Integrated Health Sciences, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Katsuhiko Kato
- Functional Medical Imaging, Biomedical Imaging Sciences, Division of Advanced Information Health Sciences, Department of Integrated Health Sciences, Nagoya University Graduate School of Medicine, Nagoya, Japan
| |
Collapse
|
2
|
Pieters H, van Staden JA, du Plessis FCP, du Raan H. Validation of a Monte Carlo simulated cardiac phantom for planar and SPECT studies. Phys Med 2023; 111:102617. [PMID: 37290226 DOI: 10.1016/j.ejmp.2023.102617] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Revised: 04/19/2023] [Accepted: 05/30/2023] [Indexed: 06/10/2023] Open
Abstract
PURPOSE This work aimed to validate Monte Carlo (MC) simulated cardiac phantoms for the evaluation of planar- and SPECT-gated-blood-pool (GBP-P and GBP-S) studies. METHODS A comparison of gamma camera system performance criteria measurements (energy resolution, spatial resolution, sensitivity) with MC simulations was conducted. Furthermore, the accuracy of measured and simulated volumes of two stereolithography-printed cardiac phantoms (based on 4D-XCAT phantoms) was assessed. Finally, the simulated GBP-P and GBP-S XCAT studies were validated by comparing calculated left ventricular ejection fraction (LVEF) and ventricle volume values with known parameters. RESULTS The simulated performance criteria compared well with measured values (energy resolution difference: 0.1 ± 0.10%; spatial resolution (full width at half maximum) difference ≤ 0.5 ± 0.8 mm and system sensitivity difference ≤ 6.2 ± 0.62cps/MBq). The measured and simulated cardiac phantoms were in good agreement; the left anterior oblique views compared well. This is supported by line profiles through these phantoms and on average, simulated counts were 5.8% lower than measured counts. The LVEF values calculated from the GBP-P and GBP-S simulated data differ from known values (2.8 ± 0.64% and 0.8 ± 0.52%). The differences between the known XCAT LV volumes and simulated GBP-S calculated volumes were -1.2 ± 1.91 ml and -1.5 ± 0.96 ml for the end-diastolic and end-systolic volumes. CONCLUSION The MC-simulated cardiac phantom has been validated successfully. Stereolithography-printing allows researchers to create clinically realistic organ phantoms and is a valuable tool for validating MC simulations and clinical software. By conducting GBP simulation studies with various XCAT models, the user will be able to generate GBP-P and GBP-S databases for future software evaluation.
Collapse
Affiliation(s)
- Hané Pieters
- Department of Medical Physics, University of the Free State, PO Box 339, Bloemfontein 9301, South Africa.
| | - Johannes A van Staden
- Department of Medical Physics, University of the Free State, PO Box 339, Bloemfontein 9301, South Africa.
| | - Frederik C P du Plessis
- Department of Medical Physics, University of the Free State, PO Box 339, Bloemfontein 9301, South Africa.
| | - Hanlie du Raan
- Department of Medical Physics, University of the Free State, PO Box 339, Bloemfontein 9301, South Africa.
| |
Collapse
|
3
|
Di Domenico G, Di Biaso S, Longo L, Turra A, Tonini E, Longo M, Uccelli L, Bartolomei M. Validation of [Formula: see text]Tc and [Formula: see text]Lu quantification parameters for a Monte Carlo modelled gamma camera. EJNMMI Phys 2023; 10:27. [PMID: 37029829 PMCID: PMC10082889 DOI: 10.1186/s40658-023-00547-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2022] [Accepted: 03/29/2023] [Indexed: 04/09/2023] Open
Abstract
PURPOSE Monte Carlo (MC) simulation in Nuclear Medicine is a powerful tool for modeling many physical phenomena which are difficult to track or measure directly. MC simulation in SPECT/CT imaging is particularly suitable for optimizing the quantification of activity in a patient, and, consequently, the absorbed dose to each organ. To do so, validating MC results with real data acquired with gamma camera is mandatory. The aim of this study was the validation of the calibration factor (CF) and the recovery coefficient (RC) obtained with SIMIND Monte Carlo code for modeling a Siemens Symbia Intevo Excel SPECT-CT gamma camera to ensure optimal [Formula: see text]Tc and [Formula: see text]Lu SPECT quantification. METHODS Phantom experiments using [Formula: see text]Tc and [Formula: see text]Lu have been performed to measure spatial resolution and sensitivity, as well as to evaluate the CF and RC from acquired data. The geometries used for 2D planar imaging were (1) Petri dish and (2) capillary source while for 3D volumetric imaging were (3) a uniform filled cylinder phantom and (4) a Jaszczack phantom with spheres of different volumes. The experimental results have been compared with the results obtained from Monte Carlo simulations performed in the same geometries. RESULTS Comparison shows good accordance between simulated and experimental data. The measured planar spatial resolution was 8.3[Formula: see text] mm for [Formula: see text]Tc and 11.8±0.6 mm for [Formula: see text]Lu. The corresponding data obtained by SIMIND for [Formula: see text]Tc was 7.8±0.1 mm, while for [Formula: see text]Lu was 12.4±0.4 mm. The CF was 110.1±5.5 cps/MBq for Technetium and 18.3±1.0 cps/MBq for Lutetium. The corresponding CF obtained by SIMIND for [Formula: see text]Tc was 107.3±0.3 cps/MBq, while for [Formula: see text]Lu 20.4±0.7 cps/MBq. Moreover, a complete curve RCs vs Volume (ml) both for Technetium and Lutetium was determined to correct the PVE for all volumes of clinical interest. In none of the cases, a RC coefficient equal to 100 was found. CONCLUSIONS The validation of quantification parameters shows that SIMIND can be used for simulating both gamma camera planar and SPECT images of Siemens Symbia Intevo using [Formula: see text]Tc and [Formula: see text]Lu radionuclides for different medical purposes and treatments.
Collapse
Affiliation(s)
- Giovanni Di Domenico
- Department of Physics and Earth Science, University of Ferrara, via Saragat 1, 44122 Ferrara, IT Italy
| | - Simona Di Biaso
- Department of Physics and Earth Science, University of Ferrara, via Saragat 1, 44122 Ferrara, IT Italy
| | - Lorenzo Longo
- Department of Physics and Earth Science, University of Ferrara, via Saragat 1, 44122 Ferrara, IT Italy
| | - Alessandro Turra
- Medical Physics Unit, University Hospital, 44124 Ferrara, IT Italy
| | - Eugenia Tonini
- Medical Physics Unit, University Hospital, 44124 Ferrara, IT Italy
| | | | - Licia Uccelli
- Nuclear Medicine Unit, University Hospital, 44124 Ferrara, IT Italy
- Department of Translational Medicine, University of Ferrara, via Fossato di Mortara, 70 c/o viale Eliporto, 44124 Ferrara, IT Italy
| | - Mirco Bartolomei
- Nuclear Medicine Unit, University Hospital, 44124 Ferrara, IT Italy
| |
Collapse
|
4
|
Ramonaheng K, van Staden JA, du Raan H. Accuracy of two dosimetry software programs for 177Lu radiopharmaceutical therapy using voxel-based patient-specific phantoms. Heliyon 2022; 8:e09830. [PMID: 35865988 PMCID: PMC9293745 DOI: 10.1016/j.heliyon.2022.e09830] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2021] [Revised: 02/18/2022] [Accepted: 06/24/2022] [Indexed: 12/01/2022] Open
Abstract
Purpose Virtual dosimetry using voxel-based patient-specific phantoms and Monte Carlo (MC) simulations offer the advantage of having a gold standard against which absorbed doses may be benchmarked to establish the dosimetry accuracy. Furthermore, these reference values assist in investigating the accuracy of the absorbed dose methodologies from different software programs. Therefore, this study aimed to compare the accuracy of the absorbed doses computed using LundADose and OLINDA/EXM 1.0. Methods The accuracy was based on 177Lu-DOTATATE distributions of three voxel-based phantoms. SPECT projection images were simulated for 1, 24, 96, and 168 h post-administration and reconstructed with LundADose using 3D OS-EM reconstruction. Mono-exponential curves were fitted to the bio-kinetic data for the kidneys, liver, spleen, and tumours resulting in SPECT time-integrated activity (SPECT-TIA). The SPECT-TIA were used to compute mean absorbed doses using LundADose (LND-DSPECT) and OLINDA (OLINDA-DSPECT) for the organs. Pre-defined true activity images, were used to obtain TRUE-TIA and, together with full MC simulations, computed the true doses (MC-DTrue). The dosimetry accuracy was assessed by comparing LND-DSPECT and OLINDA-DSPECT to MC-DTrue. Results Overall, the results presented an overestimation of the mean absorbed dose by LND-DSPECT compared to the MC-DTrue with a dosimetry accuracy ≤6.6%. This was attributed to spill-out activity from the reconstructed LND-DSPECT, resulting in a higher dose contribution than the MC-DTrue. There was a general underestimation (<8.1%) of OLINDA-DSPECT compared to MC-DTrue attributed to the geometrical difference in shape between the voxel-based phantoms and the OLINDA models. Furthermore, OLINDA-DSPECT considers self-doses while MC-DTrue reflects self-doses plus cross-doses. Conclusion The better than 10% accuracy suggests that the mean dose values obtained with LND-DSPECT and OLINDA-DSPECT approximate the true values. The mean absorbed doses of the two software programs, and the gold standard were comparable. This work shall be of use for optimising 177Lu dosimetry for clinical applications.
Collapse
Affiliation(s)
- Keamogetswe Ramonaheng
- Department of Medical Physics, Faculty of Health Sciences, University of the Free State, P.O. Box 339, Bloemfontein, 9300, South Africa
| | - Johannes A van Staden
- Department of Medical Physics, Faculty of Health Sciences, University of the Free State, P.O. Box 339, Bloemfontein, 9300, South Africa
| | - Hanlie du Raan
- Department of Medical Physics, Faculty of Health Sciences, University of the Free State, P.O. Box 339, Bloemfontein, 9300, South Africa
| |
Collapse
|
5
|
Morphis M, van Staden JA, du Raan H, Ljungberg M. Evaluation of Iodine-123 and Iodine-131 SPECT activity quantification: a Monte Carlo study. EJNMMI Phys 2021; 8:61. [PMID: 34410539 PMCID: PMC8377107 DOI: 10.1186/s40658-021-00407-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Accepted: 08/10/2021] [Indexed: 01/18/2023] Open
Abstract
Purpose The quantitative accuracy of Nuclear Medicine images, acquired for both planar and SPECT studies, is influenced by the isotope-collimator combination as well as image corrections incorporated in the iterative reconstruction process. These factors can be investigated and optimised using Monte Carlo simulations. This study aimed to evaluate SPECT quantification accuracy for 123I with both the low-energy high resolution (LEHR) and medium-energy (ME) collimators and 131I with the high-energy (HE) collimator. Methods Simulated SPECT projection images were reconstructed using the OS-EM iterative algorithm, which was optimised for the number of updates, with appropriate corrections for scatter, attenuation and collimator detector response (CDR), including septal scatter and penetration compensation. An appropriate calibration factor (CF) was determined from four different source geometries (activity-filled: water-filled cylindrical phantom, sphere in water-filled (cold) cylindrical phantom, sphere in air and point-like source), investigated with different volume of interest (VOI) diameters. Recovery curves were constructed from recovery coefficients to correct for partial volume effects (PVEs). The quantitative method was evaluated for spheres in voxel-based digital cylindrical and patient phantoms. Results The optimal number of OS-EM updates was 60 for all isotope-collimator combinations. The CFpoint with a VOI diameter equal to the physical size plus a 3.0-cm margin was selected, for all isotope-collimator geometries. The spheres’ quantification errors in the voxel-based digital cylindrical and patient phantoms were less than 3.2% and 5.4%, respectively, for all isotope-collimator combinations. Conclusion The study showed that quantification errors of less than 6.0% could be attained, for all isotope-collimator combinations, if corrections for; scatter, attenuation, CDR (including septal scatter and penetration) and PVEs are performed. 123I LEHR and 123I ME quantification accuracies compared well when appropriate corrections for septal scatter and penetration were applied. This can be useful in departments that perform 123I studies and may not have access to ME collimators.
Collapse
Affiliation(s)
- Michaella Morphis
- Department of Medical Physics, Faculty of Health Sciences, University of the Free State, PO Box 339, Bloemfontein, 9300, South Africa.
| | - Johan A van Staden
- Department of Medical Physics, Faculty of Health Sciences, University of the Free State, PO Box 339, Bloemfontein, 9300, South Africa
| | - Hanlie du Raan
- Department of Medical Physics, Faculty of Health Sciences, University of the Free State, PO Box 339, Bloemfontein, 9300, South Africa
| | | |
Collapse
|
6
|
Morphis M, van Staden JA, du Raan H, Ljungberg M. Validation of a SIMIND Monte Carlo modelled gamma camera for Iodine-123 and Iodine-131 imaging. Heliyon 2021; 7:e07196. [PMID: 34141944 PMCID: PMC8187242 DOI: 10.1016/j.heliyon.2021.e07196] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Revised: 05/11/2021] [Accepted: 05/28/2021] [Indexed: 01/16/2023] Open
Abstract
Purpose Monte Carlo (MC) modelling techniques can assess the quantitative accuracy of both planar and SPECT Nuclear Medicine images. It is essential to validate the MC code's capabilities in modelling a specific clinical gamma camera, for radionuclides of interest, before its use as a clinical image simulator. This study aimed to determine if the SIMIND MC code accurately simulates emission images measured with a Siemens Symbia™ T16 SPECT/CT system for I-123 with a LEHR and a ME collimator and for I-131 with a HE collimator. Methods The static and WB planar validation tests included extrinsic system energy pulse-height distributions (EPHDs), system sensitivity and system spatial resolution in air as well as a scatter medium. The SPECT validation test comprised the sensitivity from a simple geometry of a sphere in a cylindrical water-filled phantom. Results The system EPHDs compared well, with differences between measured and simulated primary photopeak FWHM values not exceeding 4.6 keV. Measured and simulated planar system sensitivity values displayed percentage differences less than 6.9% and 6.3% for static and WB planar images, respectively. Measured and simulated planar system spatial resolution values in air showed percentage differences not exceeding 6.4% (FWHM) and 10.0% (FWTM), and 5.1% (FWHM) and 5.4% (FWTM) for static and WB planar images, respectively. For static planar system spatial resolution measured and simulated in a scatter medium, percentage differences of FWHM and FWTM values were less than 5.8% and 12.6%, respectively. The maximum percentage difference between the measured and simulated SPECT validation results was 3.6%. Conclusion The measured and simulated validation results compared well for all isotope-collimator combinations and showed that the SIMIND MC code could be used to accurately simulate static and WB planar and SPECT projection images of the Siemens Symbia™ T16 SPECT/CT for both I-123 and I-131 with their respective collimators.
Collapse
Affiliation(s)
- Michaella Morphis
- Department of Medical Physics, Faculty of Health Sciences, University of the Free State, Bloemfontein, South Africa
| | - Johan A van Staden
- Department of Medical Physics, Faculty of Health Sciences, University of the Free State, Bloemfontein, South Africa
| | - Hanlie du Raan
- Department of Medical Physics, Faculty of Health Sciences, University of the Free State, Bloemfontein, South Africa
| | | |
Collapse
|
7
|
Zhang X, Xie Q, Xie S, Yu X, Xu J, Peng Q. A Novel Portable Gamma Radiation Sensor Based on a Monolithic Lutetium-Yttrium Oxyorthosilicate Ring. SENSORS 2021; 21:s21103376. [PMID: 34066224 PMCID: PMC8150370 DOI: 10.3390/s21103376] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/11/2021] [Revised: 04/29/2021] [Accepted: 05/06/2021] [Indexed: 11/21/2022]
Abstract
Portable radiation detectors are widely used in environmental radiation detection and medical imaging due to their portability feature, high detection efficiency, and large field of view. Lutetium-yttrium oxyorthosilicate (LYSO) is a widely used scintillator in gamma radiation detection. However, the structure and the arrangement of scintillators limit the sensitivity and detection accuracy of these radiation detectors. In this study, a novel portable sensor based on a monolithic LYSO ring was developed for the detection of environmental radiation through simulation, followed by construction and assessments. Monte Carlo simulations were utilized to prove the detection of gamma rays at 511 keV by the developed sensor. The simulations data, including energy resolutions, decoding errors, and sensitivity, showed good potential for the detection of gamma rays by the as-obtained sensor. The experimental results using the VA method revealed decoding errors in the energy window width of 50 keV less than 2°. The average error was estimated at 0.67°, a sufficient value for the detection of gamma radiation. In sum, the proposed radiation sensor appears promising for the construction of high-performance radiation detectors and systems.
Collapse
Affiliation(s)
- Xi Zhang
- The School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China; (X.Z.); (Q.X.); (X.Y.)
| | - Qiangqiang Xie
- The School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China; (X.Z.); (Q.X.); (X.Y.)
| | - Siwei Xie
- Shenzhen Bay Laboratory, The Institute of Biomedical Engineering, Shenzhen 518132, China; (S.X.); (Q.P.)
| | - Xin Yu
- The School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China; (X.Z.); (Q.X.); (X.Y.)
| | - Jianfeng Xu
- The School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China; (X.Z.); (Q.X.); (X.Y.)
- Correspondence:
| | - Qiyu Peng
- Shenzhen Bay Laboratory, The Institute of Biomedical Engineering, Shenzhen 518132, China; (S.X.); (Q.P.)
| |
Collapse
|
8
|
Ramonaheng K, van Staden JA, du Raan H. The effect of calibration factors and recovery coefficients on 177Lu SPECT activity quantification accuracy: a Monte Carlo study. EJNMMI Phys 2021; 8:27. [PMID: 33738605 PMCID: PMC7973313 DOI: 10.1186/s40658-021-00365-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Accepted: 02/08/2021] [Indexed: 12/19/2022] Open
Abstract
BACKGROUND Different gamma camera calibration factor (CF) geometries have been proposed to convert SPECT data into units of activity concentration. However, no consensus has been reached on a standardised geometry. The CF is dependent on the selected geometry and is further affected by partial volume effects. This study investigated the effect of two CF geometries and their corresponding recovery coefficients (RCs) on the quantification accuracy of 177Lu SPECT images using Monte Carlo simulations. METHODS The CF geometries investigated were (i) a radioactive-sphere surrounded by non-radioactive water (sphere-CF) and (ii) a cylindrical phantom uniformly filled with radioactive water (cylinder-CF). Recovery coefficients were obtained using the sphere-CF and cylinder-CF, yielding the sphere-RC and cylinder-RC values, respectively, for partial volume correction (PVC). The quantification accuracy was evaluated using four different-sized spheres (15.6-65.4 ml) and a kidney model with known activity concentrations inside a cylindrical, torso and patient phantom. Images were reconstructed with the 3D OS-EM algorithm incorporating attenuation, scatter and detector-response corrections. Segmentation was performed using the physical size and a small cylindrical volume inside the cylinder for the sphere-CF and cylinder-CF, respectively. RESULTS The sphere quantification error (without PVC) was better for the sphere-CF (≤ - 5.54%) compared to the cylinder-CF (≤ - 20.90%), attributed to the similar geometry of the quantified and CF spheres. Partial volume correction yielded comparable results for the sphere-CF-RC (≤ 3.47%) and cylinder-CF-RC (≤ 3.53%). The accuracy of the kidney quantification was poorer (≤ 22.34%) for the sphere-CF without PVC compared to the cylinder-CF (≤ 2.44%). With PVC, the kidney quantification results improved and compared well for the sphere-CF-RC (≤ 3.50%) and the cylinder-CF-RC (≤ 3.45%). CONCLUSION The study demonstrated that upon careful selection of CF-RC combinations, comparable quantification errors (≤ 3.53%) were obtained between the sphere-CF-RC and cylinder-CF-RC, when all corrections were applied.
Collapse
Affiliation(s)
- Keamogetswe Ramonaheng
- Department of Medical Physics, Faculty of Health Sciences, University of the Free State, PO Box 339, Bloemfontein, 9300, South Africa.
| | - Johannes A van Staden
- Department of Medical Physics, Faculty of Health Sciences, University of the Free State, PO Box 339, Bloemfontein, 9300, South Africa
| | - Hanlie du Raan
- Department of Medical Physics, Faculty of Health Sciences, University of the Free State, PO Box 339, Bloemfontein, 9300, South Africa
| |
Collapse
|
9
|
Morphis M, van Staden JA, du Raan H, Ljungberg M. Modelling of energy-dependent spectral resolution for SPECT Monte Carlo simulations using SIMIND. Heliyon 2021; 7:e06097. [PMID: 33659726 PMCID: PMC7892923 DOI: 10.1016/j.heliyon.2021.e06097] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Revised: 12/22/2020] [Accepted: 01/21/2021] [Indexed: 12/29/2022] Open
Abstract
PURPOSE Monte Carlo (MC) modelling techniques have been used extensively in Nuclear Medicine (NM). The theoretical energy resolution relationship ( ∝ 1 / E ), does not accurately predict the gamma camera detector response across all energies. This study aimed to validate the accuracy of an energy resolution model for the SIMIND MC simulation code emulating the Siemens Symbia T16 dual-head gamma camera. METHODS Measured intrinsic energy resolution data (full width half maximum (FWHM) values), for Ba-133, Lu-177, Am-241, Ga-67, Tc-99m, I-123, I-131 and F-18 sources in air, were used to create a fitted model of the energy response of the gamma camera. Both the fitted and theoretical models were used to simulate intrinsic and extrinsic energy spectra using three different scenarios (source in air; source in simple scatter phantom and a clinical voxel-based digital patient phantom). RESULTS The results showed the theoretical model underestimated the FWHM values at energies above 160.0 keV up to 23.5 keV. In contrast, the fitted model better predicted the measured FWHM values with differences less than 3.3 keV. The I-131 in-scatter energy spectrum simulated with the fitted model better matched the measured energy spectrum. Higher energy photopeaks, (I-123: 528.9 keV and I-131: 636.9 keV) simulated with the fitted model, more accurately resembled the measured photopeaks. The voxel-based digital patient phantom energy spectra, simulated with the fitted and theoretical models, showed the potential impact of an incorrect energy resolution model when simulating isotopes with multiple photopeaks. CONCLUSION Modelling of energy resolution with the proposed fitted model enables the SIMIND user to accurately simulate NM images. A great improvement was seen for high-energy photon emitting isotopes (e.g. I-131), as well as isotopes with multiple photopeaks (e.g. Lu-177, I-131 and Ga-67) in comparison to the theoretical model. This will result in accurate evaluation of radioactivity quantification, which is vital for dosimetric purposes.
Collapse
Affiliation(s)
- Michaella Morphis
- Department of Medical Physics, Faculty of Health Sciences, University of the Free State, Bloemfontein, South Africa
| | - Johan A. van Staden
- Department of Medical Physics, Faculty of Health Sciences, University of the Free State, Bloemfontein, South Africa
| | - Hanlie du Raan
- Department of Medical Physics, Faculty of Health Sciences, University of the Free State, Bloemfontein, South Africa
| | - Michael Ljungberg
- Department of Medical Radiation Physics, Lund University, Lund, Sweden
| |
Collapse
|