1
|
Marin E, Lanzutti A. Biomedical Applications of Titanium Alloys: A Comprehensive Review. MATERIALS (BASEL, SWITZERLAND) 2023; 17:114. [PMID: 38203968 PMCID: PMC10780041 DOI: 10.3390/ma17010114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Revised: 12/15/2023] [Accepted: 12/21/2023] [Indexed: 01/12/2024]
Abstract
Titanium alloys have emerged as the most successful metallic material to ever be applied in the field of biomedical engineering. This comprehensive review covers the history of titanium in medicine, the properties of titanium and its alloys, the production technologies used to produce biomedical implants, and the most common uses for titanium and its alloys, ranging from orthopedic implants to dental prosthetics and cardiovascular devices. At the core of this success lies the combination of machinability, mechanical strength, biocompatibility, and corrosion resistance. This unique combination of useful traits has positioned titanium alloys as an indispensable material for biomedical engineering applications, enabling safer, more durable, and more efficient treatments for patients affected by various kinds of pathologies. This review takes an in-depth journey into the inherent properties that define titanium alloys and which of them are advantageous for biomedical use. It explores their production techniques and the fabrication methodologies that are utilized to machine them into their final shape. The biomedical applications of titanium alloys are then categorized and described in detail, focusing on which specific advantages titanium alloys are present when compared to other materials. This review not only captures the current state of the art, but also explores the future possibilities and limitations of titanium alloys applied in the biomedical field.
Collapse
Affiliation(s)
- Elia Marin
- Ceramic Physics Laboratory, Kyoto Institute of Technology, Sakyo-ku, Kyoto 606-8585, Japan
- Department of Dental Medicine, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kamigyo-ku, Kyoto 602-8566, Japan
- Department Polytechnic of Engineering and Architecture, University of Udine, 33100 Udine, Italy
- Biomedical Research Center, Kyoto Institute of Technology, Sakyo-ku, Kyoto 606-8585, Japan
| | - Alex Lanzutti
- Department Polytechnic of Engineering and Architecture, University of Udine, 33100 Udine, Italy
| |
Collapse
|
2
|
Kato S, Nozawa M, Kim S, Sakamoto Y, Ochi H, Ishijima M. Comparison of the 5-Year Outcomes Between Standard and Short Fit-and-Fill Stems in Japanese Populations. Arthroplast Today 2022; 15:108-114. [PMID: 35774886 PMCID: PMC9237240 DOI: 10.1016/j.artd.2022.03.023] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Revised: 03/12/2022] [Accepted: 03/25/2022] [Indexed: 11/19/2022] Open
Abstract
Background Fit-and-fill stems are known to have excellent outcomes; however, severe stress shielding has been reported in Japanese populations. Short fit-and-fill stems were modified for Asians; however, there have been no previous reports of its outcome. In this study, we compared the 5-year (mean 68-month) outcomes of 2 fit-and-fill stems with different lengths (standard or short). Material and methods We reviewed 100 total hip arthroplasties in each standard- or short-stem group. Radiographs were evaluated for femoral morphology, stress shielding, bone remodeling, and fixation. Clinical evaluation was performed using the Japanese Orthopaedic Association (JOA) scores. Results There was no difference in the degree of stress shielding between the 2 groups. Significant differences were observed in radiolucent lines in zone 4 (P = .005) and cortical hypertrophy in zone 3 (P < .0001) and 5 (P = .048) between the 2 groups. The canal flare index (P < .0003), cortical index (P < .0003), height (P < .0345), and stem size (P < .0081) individually affected stress shielding in the standard-stem group. In contrast, the cortical index (P < .0107) was the only relative factor in the short-stem group. All stems were judged to have bone ingrowth. The JOA score improved significantly (P < .0001); however, there were no significant differences between the 2 groups. Conclusion The outcomes of both standard and short fit-and-fill stems were favorable. There were no significant differences in the stress shielding or JOA scores. Although there were a few differences in bone remodeling and factors affecting stress shielding, stem length reduction has been achieved without adverse effects with the Japanese femur.
Collapse
Affiliation(s)
- Suguru Kato
- Department of Orthopaedic Surgery, Juntendo University Nerima Hospital, Tokyo, Japan
- Corresponding author. Department of Orthopaedic Surgery, Juntendo University Nerima Hospital, 3-1-10 Takanodai, Nerima-ku, Tokyo 177-8521, Japan. Tel.: +81 3 5923 3111.
| | - Masahiko Nozawa
- Department of Orthopaedic Surgery, Juntendo University Nerima Hospital, Tokyo, Japan
| | - Sungon Kim
- Department of Orthopaedic Surgery, Juntendo University Nerima Hospital, Tokyo, Japan
| | - Yuko Sakamoto
- Department of Orthopaedic Surgery, Juntendo University Nerima Hospital, Tokyo, Japan
| | - Hironori Ochi
- Department of Orthopaedic Surgery, Juntendo University Nerima Hospital, Tokyo, Japan
| | - Muneaki Ishijima
- Department of Orthopaedic Surgery, Juntendo University, Tokyo, Japan
| |
Collapse
|
3
|
Peng L, Ma J, Zeng Y, Wu Y, Si H, Shen B. Clinical and radiological results of high offset tri-lock bone preservation stem in unilateral primary total hip arthroplasty at a minimum follow-up of 3 years. J Orthop Surg Res 2021; 16:635. [PMID: 34689823 PMCID: PMC8543806 DOI: 10.1186/s13018-021-02787-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Accepted: 10/11/2021] [Indexed: 02/08/2023] Open
Abstract
Background Although the high offset Tri-Lock bone preservation stem (BPS) was used widely, few studies explored the clinical and radiological results. The purpose of this study was to determine the clinical and radiological results of high offset Tri-Lock BPS in unilateral primary total hip arthroplasty (THA) at a minimum follow-up of 3 years. Methods 55 patients who underwent cementless THA with high offset Tri-lock BPS from 2017 to 2018 were followed for a minimum follow-up of 3 years. Patients were assessed clinically for complications, Harris hip score (HHS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and Oxford Hip Score (OHS). Femoral offset (FO), acetabular offset (AO), hip offset (HO), HO difference, and leg length discrepancy (LLD) were measured on the anteroposterior (AP) pelvic radiograph. Standard pelvic AP and lateral radiographs were used to evaluate for evidence of bone ingrowth, stem subsidence, stem alignment, radiolucent line around the stem, osteolysis, loosening, ectopic ossification, and femoral stress shielding. Results No patients reported complications during hospitalization nor the follow-up period. At a mean follow-up of 42.5 months, the mean HHS, WOMAC, and OHS scores showed a significant improvement from preoperative to the latest follow-up. No patients reported thigh pain. No revision nor sign of radiographic loosening had been detected. The high offset Tri-Lock BPS significantly improved the FO and HO postoperatively. HO difference and LLD were balanced postoperatively. No sign of stem subsidence, radiolucent line, osteolysis, loosening, ectopic ossification, nor severe stress shielding (more than grade 3–4) were observed at the latest follow-up. Conclusion The high offset Tri-Lock BPS demonstrated excellent clinical and radiographic outcomes at a minimum follow-up of 3 years. HO difference and LLD between legs decreased significantly and achieved balance postoperatively. Long-term follow-up is required for a definitive conclusion.
Collapse
Affiliation(s)
- Linbo Peng
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, 37# Guoxue Road, Chengdu, 610041, Sichuan Province, People's Republic of China
| | - Jun Ma
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, 37# Guoxue Road, Chengdu, 610041, Sichuan Province, People's Republic of China
| | - Yi Zeng
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, 37# Guoxue Road, Chengdu, 610041, Sichuan Province, People's Republic of China
| | - Yuangang Wu
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, 37# Guoxue Road, Chengdu, 610041, Sichuan Province, People's Republic of China
| | - Haibo Si
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, 37# Guoxue Road, Chengdu, 610041, Sichuan Province, People's Republic of China
| | - Bin Shen
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, 37# Guoxue Road, Chengdu, 610041, Sichuan Province, People's Republic of China.
| |
Collapse
|
4
|
Chen Z, Chen W, Yu W, Zhao M, Lin J, Zhou C, Chen H, Ye J, Zeng X, Zhuang J. Mid-term outcomes of uncemented or cemented arthroplasty revision following metal-on-metal total hip arthroplasty failure: a retrospective observational study. J Int Med Res 2021; 48:300060520932051. [PMID: 32600087 PMCID: PMC7328484 DOI: 10.1177/0300060520932051] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Objective To retrospectively compare the mid-term outcomes of uncemented or cemented total hip arthroplasty (THA) revision for prior primary metal-on-metal (MoM) THA failure. Methods Data from 278 patients (278 hips) who underwent uncemented THA (UTHA) or cemented THA (CTHA) for prior primary MoM-THA failure from 2006 to 2016 were retrospectively analysed. Follow-up was performed 6 months, 1 year, 2 years, and then every 2 years after conversion. The mean follow-up time was 96 months (range, 64–128 months). The primary endpoint was the modified Harris hip score (HHS). The secondary endpoint was the major orthopaedic complication rate. Results The HHS showed significantly greater differences in the CTHA than UTHA group 12 months after conversion. From the 12th month after conversion to the final follow-up, CTHA yielded better functional outcomes than UTHA. There were significant differences between the UTHA and CTHA groups in the rates of re-revision (14.4% vs. 4.9%, respectively), aseptic loosening (17.3% vs. 6.8%, respectively), and periprosthetic fracture (11.5% vs. 3.9%, respectively). Conclusion CTHA has more advantages than UTHA in terms of improving functional outcomes and decreasing the major orthopaedic complication rate.
Collapse
Affiliation(s)
- Zhao Chen
- Department of Pediatric Orthopaedics, Fujian Children's Hospital, Fuzhou, Fujian Province, China
| | - Wenli Chen
- Department of Neurosurgery, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Weiguang Yu
- Department of Orthopaedics, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Mingdong Zhao
- Department of Neurosurgery, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Jinluan Lin
- Department of Orthopaedics, Jinshan Hospital, Fudan University, Shanghai, China
| | - Chaoming Zhou
- Department of Orthopaedics, Jinshan Hospital, Fudan University, Shanghai, China
| | - Hui Chen
- Department of Orthopaedics, Jinshan Hospital, Fudan University, Shanghai, China
| | - Junxing Ye
- Department of Orthopaedics, Jinshan Hospital, Fudan University, Shanghai, China
| | - Xianshang Zeng
- Department of Orthopaedics, Jinshan Hospital, Fudan University, Shanghai, China
| | - Jintao Zhuang
- Department of Orthopaedics, Jinshan Hospital, Fudan University, Shanghai, China
| |
Collapse
|
5
|
Heaven S, Perelgut M, Vasarhelyi E, Howard J, Teeter M, Lanting B. Fully hydroxyapatite-coated collared femoral stems in direct anterior versus direct lateral hip arthroplastyFully hydroxyapatite-coated collared femoral stems in direct anterior versus direct lateral hip arthroplasty. Can J Surg 2021; 64:E205-E210. [PMID: 33769004 PMCID: PMC8064259 DOI: 10.1503/cjs.000920] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
Abstract
Background Total hip arthroplasty (THA) via the direct anterior approach has increased in popularity in the last decade, with research supporting enhanced early recovery; however, some investigators have reported increased early revision rates in direct anterior THA. We examined outcomes from a single institution's experience with a fully hydroxyapatite-coated collared femoral stem implanted via the anterior or the lateral approach. Methods Patients who had received fully hydroxyapatite-coated collared femoral stems as part of THA surgery performed by 1 of 3 surgeons between January 2012 and September 2017 were identified from our institutional database. We examined revision rates for the 2 approaches and compared them between the 2 groups. We also analyzed outcomes on plain film radiographs obtained immediately postoperatively and at 1 and 2 years. Results A total of 695 patients received a fully hydroxyapatite-coated collared stem during the study period. Total hip arthroplasty was performed via the direct anterior approach in 281/778 hips (36.1%) and via the direct lateral approach in 497 (63.9%). Nineteen patients (2.5%) underwent subsequent revision surgery; there was no statistically significant difference in the revision rate between the anterior and lateral approaches (2.5% v. 2.4%, p = 0.95). The mean subsidence of the stem at 1 year was 1.68 mm (standard deviation 11.7 mm). No statistically significant differences were observed between the cohorts for any of the radiographic measurements at either follow-up time. Conclusion We found no significant difference in revision rates between the direct anterior and direct lateral approach. Stem subsidence levels were in keeping with expected values, and no major changes in stem position occurred during the first postoperative year. Surgical approach did not appear to substantially affect biomechanical stem behaviour.
Collapse
Affiliation(s)
- Sebastian Heaven
- From the Department of Orthopaedics, London Health Sciences Centre, London, Ont. (Heaven, Vasarhelyi, Howard, Lanting); the School of Biomedical Engineering, Western University, London, Ont. (Perelgut); and the Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, Ont. (Teeter)
| | - Maxwell Perelgut
- From the Department of Orthopaedics, London Health Sciences Centre, London, Ont. (Heaven, Vasarhelyi, Howard, Lanting); the School of Biomedical Engineering, Western University, London, Ont. (Perelgut); and the Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, Ont. (Teeter)
| | - Edward Vasarhelyi
- From the Department of Orthopaedics, London Health Sciences Centre, London, Ont. (Heaven, Vasarhelyi, Howard, Lanting); the School of Biomedical Engineering, Western University, London, Ont. (Perelgut); and the Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, Ont. (Teeter)
| | - James Howard
- From the Department of Orthopaedics, London Health Sciences Centre, London, Ont. (Heaven, Vasarhelyi, Howard, Lanting); the School of Biomedical Engineering, Western University, London, Ont. (Perelgut); and the Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, Ont. (Teeter)
| | - Matthew Teeter
- From the Department of Orthopaedics, London Health Sciences Centre, London, Ont. (Heaven, Vasarhelyi, Howard, Lanting); the School of Biomedical Engineering, Western University, London, Ont. (Perelgut); and the Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, Ont. (Teeter)
| | - Brent Lanting
- From the Department of Orthopaedics, London Health Sciences Centre, London, Ont. (Heaven, Vasarhelyi, Howard, Lanting); the School of Biomedical Engineering, Western University, London, Ont. (Perelgut); and the Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, Ont. (Teeter)
| |
Collapse
|
6
|
Panichkul P, McCalden RW, MacDonald SJ, Somerville LE, Naudie DN. Minimum 15-Year Results of a Dual-Offset Uncemented Femoral Stem in Total Hip Arthroplasty. J Arthroplasty 2019; 34:2992-2998. [PMID: 31447254 DOI: 10.1016/j.arth.2019.07.003] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2019] [Revised: 06/29/2019] [Accepted: 07/01/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The aim of the present study is to assess the long-term clinical and radiological outcomes of a proximal porous-coated, dual-offset, tapered titanium alloy uncemented stem at a minimum of 15 years of follow-up. METHODS We reviewed 210 total hip arthroplasties (in 193 patients) performed between 1996 and 1999 and followed prospectively in our database who received the Synergy stem. We report a Kaplan-Meier survival analysis as well as the Harris Hip Score, the Western Ontario and McMaster University Arthritis Index, and the Short Form Health Survey-12 scores. Radiographs were evaluated for evidence of subsidence, osteolysis, osteointegration, or loosening. RESULTS The average follow-up was 16 years (range, 15-17.7 years). Kaplan-Meier survival analysis with revision of stem for aseptic mechanical loosening (1 stem) as the end point revealed a cumulative survival rate of 99.5% at 16 years. The Harris Hip Score, the Western Ontario and McMaster University Arthritis Index, and the Short Form Health Survey-12 physical scores were all significantly improved (P < .001) from the preoperative period to latest follow-up. Minor osteolysis was observed proximally in 14 hips (6.6%) with no osteolysis distal to the porous coating. CONCLUSION To our knowledge, this study represents the largest series reporting the longest clinical follow-up of this third-generation, dual-offset, proximal ingrowth, tapered cementless stem. The Synergy stem design has achieved excellent clinical outcomes, predictable osteointegration, and outstanding survivorship of 99.5% at a minimum of 15 years follow-up, representing the standard for femoral stems at our institution.
Collapse
Affiliation(s)
- Phonthakorn Panichkul
- London Health Science Centre, University of Western Ontario, London, Ontario, Canada; Bangkok Hip and Knee Center, Bangkok Hospital, Bangkok, Thailand
| | - Richard W McCalden
- London Health Science Centre, University of Western Ontario, London, Ontario, Canada
| | - Steven J MacDonald
- London Health Science Centre, University of Western Ontario, London, Ontario, Canada
| | - Lyndsay E Somerville
- London Health Science Centre, University of Western Ontario, London, Ontario, Canada
| | - Douglas N Naudie
- London Health Science Centre, University of Western Ontario, London, Ontario, Canada
| |
Collapse
|
7
|
Smith LK, Dures E, Beswick AD. Systematic review of the clinical effectiveness for long-term follow-up of total hip arthroplasty. Orthop Res Rev 2019; 11:69-78. [PMID: 31308766 PMCID: PMC6613453 DOI: 10.2147/orr.s199183] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2018] [Accepted: 03/21/2019] [Indexed: 01/08/2023] Open
Abstract
Objectives: Total hip arthroplasty (THA) is highly successful but national registries indicate that average age has lowered and that younger patients are at higher risk of revision. Long-term follow-up of THA was historically recommended to identify aseptically failing THA, minimising the risks associated with extensive changes, but follow-up services are now in decline. A systematic review was conducted to search for evidence of the clinical or cost-effectiveness of hip arthroplasty surveillance. Methods: The study was registered with PROSPERO International Prospective Register of Systematic Reviews and conducted according to PRISMA guidelines; databases included MEDLINE and Embase, and all studies were quality assessed. Original studies (2005 to 2017) reporting follow-up of adults with THA in situ >5 years were included. Researchers extracted quantitative and qualitative data from each study. Results: For eligibility, 4,137 studies were screened: 114 studies were included in the final analysis, representing 22 countries worldwide. Data extracted included study endpoint, patient detail, loss to follow-up, revisions, scores and radiographic analysis. Six themes were derived from inductive content analysis of text: support for long-term follow-up, subgroups requiring follow-up, effect of materials/techniques on THA survival, effect of design, indicators for revision, review process. Main findings-follow-up was specifically recommended to monitor change (eg asymptomatic loosening), when outcomes of joint construct are unknown, and for specific patient subgroups. Outcome scores alone are not enough, and radiographic review should be included. Conclusion: There were no studies directly evaluating the clinical effectiveness of the long-term follow-up of THA but expert opinions from a range of international authors advocated its use for defined subgroups to provide patient-centred care. In the absence of higher level evidence, these opinions, in conjunction with emerging outputs from the national joint registries, should be used to inform services for long-term follow-up of THA.
Collapse
Affiliation(s)
- Lindsay K Smith
- Department of Trauma and Orthopaedics, Weston Area Health NHS Trust, Weston-super-Mare, North Somerset, UK
| | - Emma Dures
- Centre for Health and Clinical Research, University of the West of England, Bristol, UK
| | - AD Beswick
- Musculoskeletal Research Unit, University of Bristol, Bristol, UK
| |
Collapse
|
8
|
Ohmori T, Kabata T, Kajino Y, Inoue D, Taga T, Yamamoto T, Takagi T, Yoshitani J, Ueno T, Ueoka K, Tsuchiya H. The optimal combined anteversion pattern to achieve a favorable impingement-free angle in total hip arthroplasty. J Orthop Sci 2019; 24:474-481. [PMID: 30554937 DOI: 10.1016/j.jos.2018.11.008] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/29/2018] [Revised: 10/06/2018] [Accepted: 11/08/2018] [Indexed: 11/30/2022]
Abstract
BACKGROUND There have been no studies on the differences in impingement-free angle that result from different combined anteversion (CA) patterns. The aim of this study was to find the optimal CA pattern for achieving a favorable impingement-free angle, including bony and prosthetic impingement, in total hip arthroplasty. METHODS We evaluated 100 patients with no hip arthritis. We investigated the impingement-free angle (flexion, internal rotation with 90° flexion, extension, and external rotation) after changing the stem and cup anteversions to satisfy several CA patterns [cup anteversion + stem anteversion = 30°, 40°, 50°, and 60°; cup anteversion + 0.7 × stem anteversion = 37.3° (:Widmer's theory); and cup anteversion + 0.77 × stem anteversion = 43.3° (:Yoshimine's theory)] using 3-dimensional templating software. RESULTS The impingement-free angle changed dramatically among the various CA patterns. The optimal CA was changed by various stem anteversion. Only CA: Widmer with stem anteversion of 20° satisfied daily-life range of motion (ROM) requirements (flexion ≥130°, internal rotation with 90° flexion ≥ 45°, extension ≥ 40°, external rotation ≥ 40°). CONCLUSION Good impingement-free angle cannot be obtained with single fixed CA. Different CA patterns should be used, depending on the differences in the stem anteversion. A CA of 30° with 0° ≤ stem anteversion ≤10°; a CA:Widmer with 20° of stem anteversion; a CA of 40° or Widmer with 30° of stem anteversion. When stem anteversion is ≥40°, CA should be decided by each patient's state. Among them, a stem anteversion of 20° with cup anteversion of 23.3° was found to be the best CA pattern.
Collapse
Affiliation(s)
- Takaaki Ohmori
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kanazawa University, 13-1 Takaramachi, Kanazawa, Ishikawa, 920-8641, Japan
| | - Tamon Kabata
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kanazawa University, 13-1 Takaramachi, Kanazawa, Ishikawa, 920-8641, Japan.
| | - Yoshitomo Kajino
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kanazawa University, 13-1 Takaramachi, Kanazawa, Ishikawa, 920-8641, Japan
| | - Daisuke Inoue
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kanazawa University, 13-1 Takaramachi, Kanazawa, Ishikawa, 920-8641, Japan
| | - Tadashi Taga
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kanazawa University, 13-1 Takaramachi, Kanazawa, Ishikawa, 920-8641, Japan
| | - Takashi Yamamoto
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kanazawa University, 13-1 Takaramachi, Kanazawa, Ishikawa, 920-8641, Japan
| | - Tomoharu Takagi
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kanazawa University, 13-1 Takaramachi, Kanazawa, Ishikawa, 920-8641, Japan
| | - Junya Yoshitani
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kanazawa University, 13-1 Takaramachi, Kanazawa, Ishikawa, 920-8641, Japan
| | - Takuro Ueno
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kanazawa University, 13-1 Takaramachi, Kanazawa, Ishikawa, 920-8641, Japan
| | - Ken Ueoka
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kanazawa University, 13-1 Takaramachi, Kanazawa, Ishikawa, 920-8641, Japan
| | - Hiroyuki Tsuchiya
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kanazawa University, 13-1 Takaramachi, Kanazawa, Ishikawa, 920-8641, Japan
| |
Collapse
|
9
|
Dikmen G, Ozden VE, Beksac B, Tozun IR. Dual offset metaphyseal-filling stems in primary total hip arthroplasty in dysplastic hips after a minimum follow-up of ten years. INTERNATIONAL ORTHOPAEDICS 2018; 43:2039-2046. [PMID: 30232526 DOI: 10.1007/s00264-018-4161-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2018] [Accepted: 09/12/2018] [Indexed: 12/01/2022]
Abstract
PURPOSE The aim of this study was to assess the long-term performance of tapered one-third proximally coated stems in dysplastic hips. METHODS This study included 135 dysplasia patients (150 hips) who underwent a total hip arthroplasty and had a minimum follow-up of ten years. Single design tapered stems were used in all patients. There were 112 women (83%) and 23 men (17%) with a mean age of 45 years (23 to 72) at the time of surgery. The mean follow-up was 14.7 years (10 to 16.8). For clinical evaluation, the Harris Hip Score and Merle D'Aubigne scale were used pre-operatively and at the final follow-up. Implant survival was calculated using Kaplan-Meier survivorship analysis, with failure defined as a component revision for any reason. RESULTS Overall, one stem was revised for a deep infection. There were no other femoral stem revisions secondary to loosening, wear, periprosthetic fracture, or instability. Radiographic evaluation showed excellent stem osteointegration in all cases. Kaplan-Meier survivorship, with stem revision for any reason as the end point, was 98% at 14 years (95% confidence interval 92.5 to 99.8). CONCLUSION This study demonstrates that a dual offset tapered stem achieved excellent survivorship and stability, as well as good clinical outcome scores with minimal thigh pain and stress shielding in patients with arthritis and developmental dysplasia of the hip; a dual offset tapered stem may be a suitable option for primary total hip arthroplasty in this group.
Collapse
Affiliation(s)
- Goksel Dikmen
- Acibadem Mehmet Ali Aydinlar University, Faculty of Medicine, Department of Orthopedics and Traumatology, Acibadem Maslak Hospital, Buyukdere Cad No 40 34457, Maslak, Istanbul, Turkey.
| | - Vahit Emre Ozden
- Acibadem Mehmet Ali Aydinlar University, Faculty of Medicine, Department of Orthopedics and Traumatology, Acibadem Maslak Hospital, Buyukdere Cad No 40 34457, Maslak, Istanbul, Turkey
| | - Burak Beksac
- Department of Orthopedics and Traumatology, Acibadem Maslak Hospital, Buyukdere Cad No 40 34457, Maslak, Istanbul, Turkey
| | - Ismail Remzi Tozun
- Acibadem Mehmet Ali Aydinlar University, Faculty of Medicine, Department of Orthopedics and Traumatology, Acibadem Maslak Hospital, Buyukdere Cad No 40 34457, Maslak, Istanbul, Turkey
| |
Collapse
|
10
|
Hossain F, Konan S, Volpin A, Haddad FS. Early performance-based and patient-reported outcomes of a contemporary taper fit bone-conserving short stem femoral component in total hip arthroplasty. Bone Joint J 2017; 99-B:49-55. [DOI: 10.1302/0301-620x.99b4.bjj-2016-1291.r1] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2016] [Accepted: 01/11/2017] [Indexed: 01/17/2023]
Abstract
Aims The aim of this study was to compare early functional and health related quality of life outcomes (HRQoL) in patients who have undergone total hip arthroplasty (THA) using a bone conserving short stem femoral component and those in whom a conventional length uncemented component was used. Outcome was assessed using a validated performance based outcome instrument as well as patient reported outcome measures (PROMs). Patients and Methods We prospectively analysed 33 patients whose THA involved a contemporary proximally porous coated tapered short stem femoral component and 53 patients with a standard conventional femoral component, at a minimum follow-up of two years. The mean follow-up was 31.4 months (24 to 39). Patients with poor proximal femoral bone quality were excluded. The mean age of the patients was 66.6 years (59 to 77) and the mean body mass index was 30.2 kg/m2 (24.1 to 41.0). Outcome was assessed using the Oxford Hip Score (OHS) and the University College Hospital (UCH) hip score which is a validated performance based instrument. HRQoL was assessed using the EuroQol 5D (EQ-5D). Results There were no major peri-operative complications. There was no difference in the mean post-operative OHS, EQ-5D or function subscale of the UCH hip scores between the two groups. The mean pre-operative OHS and EQ-5D scores improved significantly (all p < 0.001). The mean functional component of the UCH hip score at final follow-up was 42.5 and 40.6 in the short stem and conventional stem groups, respectively. There was no statistically significant difference between the groups (p = 0.42). A total of seven patients (21.2%) in the short stem group and nine (16.98%) in the conventional group achieved a ceiling effect using the OHS; none did using the function subscale of the UCH hip score. Conclusion The proximally porous coated tapered short stem femoral component achieves comparable short-term functional outcomes when compared with a conventional longer stem uncemented femoral component when THA is undertaken in patients with good bone quality. Cite this article: Bone Joint J 2017;99-B(4 Supple B):49–55.
Collapse
Affiliation(s)
- F. Hossain
- University College London Hospital, 250
Euston Road, London, UK
| | - S. Konan
- University College London Hospital, 250
Euston Road, London, UK
| | - A. Volpin
- University College London Hospital, 250
Euston Road, London, UK
| | - F. S. Haddad
- University College London Hospitals, 235
Euston Road, London NW1 2BU UK and NIHR University College London
Hospitals, Biomedical Research Centre, UK
| |
Collapse
|
11
|
Meermans G, Doorn JV, Kats JJ. Restoration of the centre of rotation in primary total hip arthroplasty: the influence of acetabular floor depth and reaming technique. Bone Joint J 2017; 98-B:1597-1603. [PMID: 27909120 DOI: 10.1302/0301-620x.98b12.bjj-2016-0345.r1] [Citation(s) in RCA: 56] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/28/2016] [Accepted: 08/16/2016] [Indexed: 01/14/2023]
Abstract
AIMS One goal of total hip arthroplasty is to restore normal hip anatomy. The aim of this study was to compare displacement of the centre of rotation (COR) using a standard reaming technique with a technique in which the acetabulum was reamed immediately peripherally and referenced off the rim. PATIENTS AND METHODS In the first cohort the acetabulum was reamed to the floor followed by sequentially larger reamers. In the second cohort the acetabulum was only reamed peripherally, starting with a reamer the same size as the native femoral head. Anteroposterior pelvic radiographs were analysed for acetabular floor depth and vertical and horizontal position of the COR. RESULTS Horizontally, the mean medial displacement of the COR was 0.8 mm (standard deviation (sd) 1.4) in the peripheral remaing group and 5.0 mm (sd 3.30) in the standard reaming group (p < 0.001). Vertically, the mean superior displacement of the COR was 0.7 mm (sd 1.3) in the peripheral reaming group and 3.7 mm (sd 2.6) in the standard reaming group (p < 0.001). In the standard reaming group, there was a strong correlation between the pre-operative acetabular floor depth and displacement of the COR (p < 0.001). CONCLUSION Reaming the acetabulum to the floor can lead to significant displacement of the COR medially and superiorly. This displacement is related to the pre-operative acetabular floor depth and cannot always be compensated by using a high offset stem. Cite this article: Bone Joint J 2016;98-B:1597-603.
Collapse
Affiliation(s)
- G Meermans
- Bravis Hospital, Boerhaaveplein 1, 4624VT Bergen op Zoom, The Netherlands
| | - J Van Doorn
- Bravis Hospital, Boerhaaveplein 1, 4624VT Bergen op Zoom, The Netherlands
| | - J-J Kats
- Bravis Hospital, Boerhaaveplein 1, 4624VT Bergen op Zoom, The Netherlands
| |
Collapse
|
12
|
Carli AV, Negus JJ, Haddad FS. Periprosthetic femoral fractures and trying to avoid them: what is the contribution of femoral component design to the increased risk of periprosthetic femoral fracture? Bone Joint J 2017; 99-B:50-59. [PMID: 28042119 DOI: 10.1302/0301-620x.99b1.bjj-2016-0220.r1] [Citation(s) in RCA: 113] [Impact Index Per Article: 16.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2016] [Accepted: 06/27/2016] [Indexed: 11/05/2022]
Abstract
AIMS Periprosthetic femoral fractures (PFF) following total hip arthroplasty (THA) are devastating complications that are associated with functional limitations and increased overall mortality. Although cementless implants have been associated with an increased risk of PFF, the precise contribution of implant geometry and design on the risk of both intra-operative and post-operative PFF remains poorly investigated. A systematic review was performed to aggregate all of the PFF literature with specific attention to the femoral implant used. PATIENTS AND METHODS A systematic search strategy of several journal databases and recent proceedings from the American Academy of Orthopaedic Surgeons was performed. Clinical articles were included for analysis if sufficient implant description was provided. All articles were reviewed by two reviewers. A review of fundamental investigations of implant load-to-failure was performed, with the intent of identifying similar conclusions from the clinical and fundamental literature. RESULTS In total 596 articles were initially identified, with 34 being eligible for analysis. Aggregate analysis of 1691 PFFs in 342 719 primary THAs revealed a significantly higher number of PFFs with cementless femoral implants (p < 0.001). Single-wedge and double-wedge (fit-and-fill) femoral implants were associated with a threefold increase in PFF rates (p < 0.001) compared with anatomical, fully coated and tapered/rounded stems. Within cemented stems, loaded-taper (Exeter) stems were associated with more PFFs than composite-beam (Charnley) stems (p = 0.004). Review of the fundamental literature revealed very few studies comparing cementless component designs. CONCLUSION Very few studies within the PFF literature provide detailed implant information. Cementless implants, specifically those of single-wedge and double-wedge, have the highest PFF rates in the literature, with most investigations recommending against their use in older patients with osteoporotic bone. This review illustrates the need for registries and future PFF studies to record implant name and information for future analysis. Furthermore, future biomechanical investigations comparing modern implants are needed to clarify the precise contribution of implant design to PFF risk. Cite this article: Bone Joint J 2017;99-B(1 Supple A):50-9.
Collapse
Affiliation(s)
- A V Carli
- Hospital for Special Surgery, 535 East 70th Street, New York, NY 10021, USA
| | - J J Negus
- University College London Hospitals, 235 Euston Road, London, NW1 2BU and NIHR University College London Hospitals Biomedical Research Centre, UK
| | - F S Haddad
- University College London Hospitals, 235 Euston Road, London, NW1 2BU and NIHR University College London Hospitals Biomedical Research Centre, UK
| |
Collapse
|
13
|
Cementless lateralized stems in primary THA: Mid-term survival and risk factors for failure in 172 stems. Orthop Traumatol Surg Res 2017; 103:15-19. [PMID: 27914976 DOI: 10.1016/j.otsr.2016.10.011] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2016] [Revised: 09/27/2016] [Accepted: 10/07/2016] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Increasing the femoral offset when performing total hip arthroplasty (THA) theoretically increases the stresses and risks of the stem not integrating itself into bone. But this concept has not been validated for cementless stems; this led us to conduct a retrospective study to determine: (1) the risk factors for the occurrence of symptomatic femoral radiological abnormalities, (2) the incidence of these abnormal radiological findings, (3) the revision rate for aseptic non-integration of a cementless lateralized stem. HYPOTHESIS Young patients with significant femoral canal flare and a small cementless lateralized stem have a higher risk of abnormal osseointegration. MATERIAL AND METHODS We analyzed retrospectively 172 consecutive lateralized stems (KHO, Corail™ product line) implanted during primary THA between 2006 and 2012 in 157 patients (mean age 68years±12.6 (20-95), 89% men). Radiographs were used to evaluate osseointegration scores, offset restoration and the Noble index. Kaplan-Meier survival analysis was performed using "symptomatic femoral radiological abnormalities" and "revision for aseptic stem non-integration" as endpoints. RESULTS The mean follow-up was 5.9years±2.7 (range, 2-12.4years). Being more than 70years of age (HR=0.7, 95% CI: [0.3-0.9], P=0.004) and having a larger stem (HR=0.6, 95% CI: [0.4-0.9], P=0.03) were protective against symptomatic femoral radiological abnormalities, while increasing the postoperative femoral offset (HR=1.1, 95% CI: [1.01-1.2], P=0.02) was deleterious. The survival free of "symptomatic femoral radiological abnormalities" was 93% (95% CI: 89-97) at 5years and 84% (95% CI: 75-95) at 8years. The survival free of "revision for aseptic stem non-integration" was 98% (95% CI: 96.8-100) at 5years and 97% (95% CI: 95.2-100) at 8years. DISCUSSION In this study, the risk factors for symptomatic radiological abnormalities were being less than 70years of age, having a small lateralized stem and restoring a large femoral offset. Lateralized stems used in this study had a 10% rate of symptomatic radiological abnormalities and a 4% rate of revision for aseptic non-integration. LEVEL OF EVIDENCE IV, retrospective study.
Collapse
|
14
|
Abstract
INTRODUCTION Total hip replacement is a successful procedure with long survival records compared to other joint arthroplasties. Cemented implants have been available for many years, however the complications associated with loosening and, ultimately, failure over time has led to the development of cementless stems and implants.The ideal prosthesis should recreate a biomechanically normal hip joint, allow pain-free function and last the patient's life span without requiring revision. Optimal results with uncemented femoral stems rely on obtaining initial stability, osseointegration, biological fixation, and uniform stress transfer to the proximal bone.There are a multitude of factors that can affect the integration, stability and fixation of these stems into bone, and understanding these factors is the key to choosing the appropriate implant for a specific femur. METHODS This article aims to discuss cementless prostheses based on evidence-based practice. Geometry, roughness, stem coating, technique and bone quality are among the factors discussed. This was achieved through a review of the current literature. CONCLUSIONS Uncemented femoral stems have shown good, long-term survivorship and functional outcome, with promising results in younger patients.Limitations in the current literature make it difficult to assess and compare different designs to determine optimal indications for each type.Biological fixation, in which the prosthesis is directly fixed to the bone, is the preferred fixation method.Future studies of cementless implants should consistently address patient age, activity level, bone type, and deformities so that more definitive conclusions can be drawn about when to use each design.
Collapse
|
15
|
Matsuyama K, Ishidou Y, Guo YM, Kakoi H, Setoguchi T, Nagano S, Kawamura I, Maeda S, Komiya S. Finite element analysis of cementless femoral stems based on mid- and long-term radiological evaluation. BMC Musculoskelet Disord 2016; 17:397. [PMID: 27642748 PMCID: PMC5028915 DOI: 10.1186/s12891-016-1260-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/19/2016] [Accepted: 09/15/2016] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Femoral bone remodeling in response to stress shielding induces periprosthetic bone loss. Computerized finite element analysis (FEA) is employed to demonstrate differences in initial stress distribution. However, FEA is often performed without considering the precise sites at which the stem was fixed. We determined whether FEA reflects mid-term radiological examination exactly as predicted following long-term stress shielding. METHODS Femur-stem fixation sites were evaluated radiologically according to the location of spot welds in two anatomical cementless stem designs. Based on mid-term radiological results, four femur-stem bonding site conditions were defined as: (Condition A) no bonding; (Condition B) bonding within the 10 mm area proximal to the distal border of the porous area; (Condition C) bonding of the entire porous area; and (Condition D) bonding of the entire femoral stem, prior to conducting FEA analysis. Furthermore, we radiographically evaluated mid- and long-term stress shielding, and measured bone mineral density of the femur 10 years after total hip arthroplasty. RESULTS Spot welds appeared frequently around the border between the porous and smooth areas. FEA showed that, based on mid-term radiological evaluation, von Mises stress was reduced in condition B in the area proximal to the femur-stem bonding sites for both stem designs compared with condition A (no bonding). Conversely, von Mises stress at all areas of the femur-stem bonding sites in conditions C and D was higher than that in condition A. With respect to stress shielding progression, there was no significant difference between the two types of stem designs. However, stress shielding progressed and was significantly higher in the presence of spot welds (p = 0.001). In both stem designs, bone mineral density in zone VII was significantly lower than that in the contralateral hips. CONCLUSIONS These results indicate that FEA based on mid-term radiological evaluation may be helpful to predict the influence of long-term stress shielding more precisely.
Collapse
Affiliation(s)
- Kanehiro Matsuyama
- Department of Medical Joint Materials, Graduate School of Medical and Dental Science, Kagoshima University, 8-35-1 Sakuragaoka, Kagoshima, 890-8520, Japan
| | - Yasuhiro Ishidou
- Department of Medical Joint Materials, Graduate School of Medical and Dental Science, Kagoshima University, 8-35-1 Sakuragaoka, Kagoshima, 890-8520, Japan.
| | - Yong-Ming Guo
- Department of Mechanical Engineering, Graduate School of Science and Engineering, Kagoshima University, Kagoshima, Japan
| | - Hironori Kakoi
- Department of Orthopaedic Surgery, Graduate School of Medical and Dental Science, Kagoshima University, Kagoshima, Japan
| | - Takao Setoguchi
- The Near-Future Locomotor Organ Medicine Creation Course (Kusunoki Kai), Graduate School of Medical and Dental Science, Kagoshima University, Kagoshima, Japan
| | - Satoshi Nagano
- Department of Orthopaedic Surgery, Graduate School of Medical and Dental Science, Kagoshima University, Kagoshima, Japan
| | - Ichiro Kawamura
- Department of Medical Joint Materials, Graduate School of Medical and Dental Science, Kagoshima University, 8-35-1 Sakuragaoka, Kagoshima, 890-8520, Japan
| | - Shingo Maeda
- Department of Medical Joint Materials, Graduate School of Medical and Dental Science, Kagoshima University, 8-35-1 Sakuragaoka, Kagoshima, 890-8520, Japan
| | - Setsuro Komiya
- Department of Medical Joint Materials, Graduate School of Medical and Dental Science, Kagoshima University, 8-35-1 Sakuragaoka, Kagoshima, 890-8520, Japan.,Department of Orthopaedic Surgery, Graduate School of Medical and Dental Science, Kagoshima University, Kagoshima, Japan.,The Near-Future Locomotor Organ Medicine Creation Course (Kusunoki Kai), Graduate School of Medical and Dental Science, Kagoshima University, Kagoshima, Japan
| |
Collapse
|
16
|
Oliveira AL, Azevedo DC, Eajazi A, Palmer WE, Kwon YM, Bredella MA, Torriani M. Assessment of total hip arthroplasty as a predisposing factor for ischiofemoral impingement. Skeletal Radiol 2015; 44:1755-60. [PMID: 26260537 DOI: 10.1007/s00256-015-2229-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/23/2015] [Revised: 06/23/2015] [Accepted: 07/27/2015] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To examine the effect of total hip arthroplasty (THA) on ischiofemoral (IF) and quadratus femoris (QF) spaces with the hypothesis that THA does not affect ischiofemoral relationships. MATERIALS AND METHODS The study was IRB approved and complied with HIPAA guidelines. We identified consecutive MR examinations (pelvis and/or hip) obtained at our institution in adults (≥18 years old) screened for THA-related complications. Native hips from the same individuals served as controls. We collected medical record data including age, gender, surgical history, and THA designs. Two radiologists independently measured the IF-RAD and IF-MRI (IF space on radiographs and MR imaging, respectively) and QF space (on MR imaging). Groups were compared using ANCOVA controlled for gender. RESULTS The study group comprised 250 hips (132 subjects; 162 post-THA and 88 native hips). Subjects were aged 59 ± 10 years, with 66 males and 66 females. Comparison of IF-MRI and QF spaces between native and post-THA hips showed no differences (P > 0.12) and IF-RAD was higher in post-THA subjects (P = 0.01). No differences in the IF-MRI and QF spaces were present between native hips and different THA designs (P > 0.4). IF-RAD of metal-on-metal THA was higher than that of native hips (P = 0.01) and trended higher than ceramic-on-polyethylene THA (P = 0.08), with the remaining comparisons showing no significant differences (P > 0.4). CONCLUSIONS Radiographic- and MRI-based measures in patients with standard THA do not show narrowing of IF and QF spaces.
Collapse
Affiliation(s)
- Adriana L Oliveira
- Division of Musculoskeletal Imaging and Intervention, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - Debora C Azevedo
- Division of Musculoskeletal Imaging and Intervention, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - Alireza Eajazi
- Division of Musculoskeletal Imaging and Intervention, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - William E Palmer
- Division of Musculoskeletal Imaging and Intervention, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - Young-Min Kwon
- Department of Orthopedics, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - Miriam A Bredella
- Division of Musculoskeletal Imaging and Intervention, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - Martin Torriani
- Division of Musculoskeletal Imaging and Intervention, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA.
- Division of Musculoskeletal Imaging and Intervention Department of Radiology, Massachusetts General Hospital, 55 Fruit Street-YAW 6048, Boston, MA, 02114, USA.
| |
Collapse
|
17
|
Petis SM, Howard JL, McAuley JP, Somerville L, McCalden RW, MacDonald SJ. Comparing the long-term results of two uncemented femoral stems for total hip arthroplasty. J Arthroplasty 2015; 30:781-5. [PMID: 25773575 DOI: 10.1016/j.arth.2014.07.024] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/03/2014] [Revised: 07/04/2014] [Accepted: 07/19/2014] [Indexed: 02/01/2023] Open
Abstract
327 proximal and 185 extensively coated femoral stems with mean 10-year follow-up were reviewed. Implant survivorship, clinical outcomes, and radiographic analyses were compared. Kaplan-Meier implant survivorship was 97.5% for the proximal, and 98.8% for the extensively coated stem for stem-only revisions at 10-years. The proximally coated stem outperformed on the PCS arm of the SF-12 (P = 0.04) and stiffness arm of the WOMAC (P = 0.03). Otherwise, all clinical outcomes were comparable. Thigh pain incidence was 12.5% and 5.3% for the extensive versus proximally coated groups, respectively (P = 0.007). Radiographic review identified more severe stress shielding (P < 0.001) in the extensively coated stems. This study supports the long-term clinical track record of total hip arthroplasty using two different cementless stem designs.
Collapse
Affiliation(s)
- Stephen M Petis
- Division of Orthopedic Surgery, London Health Sciences Center, University Hospital, London, Ontario, Canada
| | - James L Howard
- Division of Orthopedic Surgery, London Health Sciences Center, University Hospital, London, Ontario, Canada
| | - James P McAuley
- Division of Orthopedic Surgery, London Health Sciences Center, University Hospital, London, Ontario, Canada
| | - Lyndsay Somerville
- Division of Orthopedic Surgery, London Health Sciences Center, University Hospital, London, Ontario, Canada
| | - Richard W McCalden
- Division of Orthopedic Surgery, London Health Sciences Center, University Hospital, London, Ontario, Canada
| | - Steven J MacDonald
- Division of Orthopedic Surgery, London Health Sciences Center, University Hospital, London, Ontario, Canada
| |
Collapse
|
18
|
McCalden RW, Korczak A, Somerville L, Yuan X, Naudie DD. A randomised trial comparing a short and a standard-length metaphyseal engaging cementless femoral stem using radiostereometric analysis. Bone Joint J 2015; 97-B:595-602. [DOI: 10.1302/0301-620x.97b5.34994] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
This was a randomised controlled trial studying the safety of a new short metaphyseal fixation (SMF) stem. We hypothesised that it would have similar early clinical results and micromovement to those of a standard-length tapered Synergy metaphyseal fixation stem. Using radiostereometric analysis (RSA) we compared the two stems in 43 patients. A short metaphyseal fixation stem was used in 22 patients and a Synergy stem in 21 patients. No difference was found in the clinical outcomes pre- or post-operatively between groups. RSA showed no significant differences two years post-operatively in mean micromovement between the two stems (except for varus/valgus tilt at p = 0.05) (subsidence 0.94 mm (sd 1.71) vs 0.32 mm (sd 0.45), p = 0.66; rotation 0.96° (sd 1.49) vs 1.41° (sd 2.95), p = 0.88; and total migration 1.09 mm (sd 1.74) vs 0.73 mm (sd 0.72), p = 0.51). A few stems (four SMF and three Synergy) had initial migration > 1.0 mm but stabilised by three to six months, with the exception of one SMF stem which required revision three years post-operatively. For most stems, total micromovement was very low at two years (subsidence < 0.5 mm, rotation < 1.0°, total migration < 0.5 mm), which was consistent with osseous ingrowth. The small sample makes it difficult to confirm the universal applicability of or elucidate the potential contraindications to the use of this particular new design of stem. Cite this article: Bone Joint J 2015; 97-B:595–602.
Collapse
Affiliation(s)
- R. W. McCalden
- University Hospital, 339
Windermere Road, London, Ontario
N6A 5A5, Canada
| | - A. Korczak
- University Hospital, 339
Windermere Road, London, Ontario
N6A 5A5, Canada
| | - L. Somerville
- University Hospital, 339
Windermere Road, London, Ontario
N6A 5A5, Canada
| | - X. Yuan
- Western University, 1151
Richmond Street, London, Ontario
N6A 3K7, Canada
| | - D. D. Naudie
- University Hospital, 339
Windermere Road, London, Ontario
N6A 5A5, Canada
| |
Collapse
|
19
|
Rachid A, Moncef E, Najib A, Abdeljaouad N, Abdelkarim D, Hicham Y. [Femoral offset and hip functioning in total hip prosthesis]. Pan Afr Med J 2014; 18:68. [PMID: 25400835 PMCID: PMC4230224 DOI: 10.11604/pamj.2014.18.68.3186] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2013] [Accepted: 04/03/2014] [Indexed: 11/13/2022] Open
Abstract
L'offset fémoral est l’élément pronostic le plus important dans l'arthroplastie de la hanche. Sa restauration est devenue de plus en plus une obligation. Toute modification de la valeur native de l'offset retenti sur la qualité du fonctionnement clinique de la hanche. Le but de notre travail était d’évaluer le fonctionnement clinique de la hanche en fonction de la valeur de l'offset fémoral après une arthroplastie. C'est une étude rétrospective effectuée entre 2010 et 2013, comportant 27 patients ayant bénéficiés d'une arthroplastie totale de la hanche. Les patients ayant eu un geste chirurgicale antérieur sur la même hanche ou sur la hanche controlatérale ont été exclus. Les mesures ont été effectuées sur des radiographies standards de la hanche en rotation interne d'environ 15°, avec un agrandissement à 100%. Les résultats cliniques étaient évalués au moyen du score de WOMAC qui était en moyenne de 15,2 points, et le score de Merle d'Aubigné-Postel avec une moyenne de 15 points. Deux autres tests ont été évalués dans notre étude qui sont le step et le hop test. Les meilleurs résultats fonctionnels ont été obtenus chez les patients ayant eu une latéralisation de la tige fémoral avec un offset augmenté.
Collapse
Affiliation(s)
| | - Erraji Moncef
- Service de Traumatologie-Orthopédie, CHU Mohammed VI, Oujda, Maroc
| | - Abbassi Najib
- Service de Traumatologie-Orthopédie, CHU Mohammed VI, Oujda, Maroc
| | | | - Daudi Abdelkarim
- Service de Traumatologie-Orthopédie, CHU Mohammed VI, Oujda, Maroc
| | - Yacoubi Hicham
- Service de Traumatologie-Orthopédie, CHU Mohammed VI, Oujda, Maroc
| |
Collapse
|
20
|
Nishino T, Mishima H, Kawamura H, Shimizu Y, Miyakawa S, Ochiai N. Follow-up results of 10-12 years after total hip arthroplasty using cementless tapered stem -- frequency of severe stress shielding with synergy stem in Japanese patients. J Arthroplasty 2013; 28:1736-40. [PMID: 23540537 DOI: 10.1016/j.arth.2013.02.027] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/29/2012] [Revised: 02/14/2013] [Accepted: 02/21/2013] [Indexed: 02/01/2023] Open
Abstract
Synergy stems are tapered stems featuring a proximal porous coating, grid blasting below the proximal third to the distal end. This study included 41 patients (50 hips) who underwent total hip arthroplasty with follow-ups for 10 years or more. No stem reimplantations were performed. Spot welds were observed in the distal stem in Gruen zones 3 and 5 in 35 and 32 hips, respectively. First-degree stress shielding occurred in 8 hips; 2nd-degree, 20 hips; 3rd-degree, 13 hips; and 4th-degree, 9 hips. Because of bone fixation to the distal grit-blasted section of the stem, severe stress shielding was observed in nearly half of the cases. Multiple regression analysis of stress shielding determinants revealed a correlation between stem size and short patient height, showing the cause of stress shielding to be a mismatch in size between the stem and the femoral bone.
Collapse
Affiliation(s)
- Tomofumi Nishino
- Department of Orthopaedic Surgery, University of Tsukuba, Tsukuba, Ibaraki, Japan
| | | | | | | | | | | |
Collapse
|
21
|
Pal B, Gupta S. The effect of primary stability on load transfer and bone remodelling within the uncemented resurfaced femur. Proc Inst Mech Eng H 2011; 225:549-61. [PMID: 22034739 DOI: 10.1177/0954411910397102] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
One of the major causes of aseptic loosening in an uncemented implant is the lack of any attachment between the implant and the bone. The implant’s stability depends on a combination of primary stability (mechanical stability) and secondary stability (biological stability). The primary stability may affect the implant–bone interface condition and thus influence the load transfer and mechanical stimuli for bone remodelling in the resurfaced femur. This paper reports the results of a study into the affect of primary stability on load transfer and bone adaptation for an uncemented resurfaced femur. Three-dimensional finite element models were used to simulate the intact and resurfaced femurs and the bone remodelling. As a first step towards assessing the immediate post-operative condition, a debonded interfacial contact condition with varying levels of the friction coefficient (0.4, 0.5, and 0.6) was simulated at the implant–bone interface. Then, using a threshold value of micromotion of 50 µm, the implant–bone interfacial condition was varied along the implant–bone boundary to mechanically represent non-osseointegrated or osseointegrated regions of the interface. The considered applied loading conditions included normal walking and stair climbing. Resurfacing leads to strain shielding in the femoral head (20–75 per cent strain reductions). In immediate post-operative conditions, there was no occurrence of elevated strains in the cancellous bone around the proximal femoral neck–component junction resulting in a lower risk of neck fracture. Predominantly, the micromotions were observed to remain below 50 µm at the implant–bone interface, which represents 97–99 per cent of the interfacial surface area. The predicted micromotions at the implant–bone interface strongly suggest the likelihood of bone ingrowth onto the coated surface of the implant, thereby enhancing implant fixation. For the osseointegrated implant–bone interface, the effect of strain shielding was observed in a considerably greater bone volume in the femoral head as compared to the initial debonded interfacial condition. A 50–80 per cent periprosthetic bone density reduction was predicted as compared to the value of the intact femur, indicating bone resorption within the superior resurfaced head. Although primary fixation of the resurfacing component may be achieved, the presence of high strain shielding and peri-prosthetic bone resorption are a major concern.
Collapse
Affiliation(s)
- Bidyut Pal
- Department of Mechanical Engineering, Indian Institute of Technology, Kharagpur, West Bengal, India
| | - Sanjay Gupta
- Department of Mechanical Engineering, Indian Institute of Technology, Kharagpur, West Bengal, India
| |
Collapse
|
22
|
Khanuja HS, Vakil JJ, Goddard MS, Mont MA. Cementless femoral fixation in total hip arthroplasty. J Bone Joint Surg Am 2011; 93:500-9. [PMID: 21368083 DOI: 10.2106/jbjs.j.00774] [Citation(s) in RCA: 319] [Impact Index Per Article: 24.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
A number of cementless femoral stems are associated with excellent long-term survivorship. Cementless designs differ from one another in terms of geometry and the means of obtaining initial fixation. Strict classification of stem designs is important in order to compare results among series. Loosening and thigh pain are less prevalent with modern stem designs. Stress-shielding is present in most cases, even with newer stem designs.
Collapse
Affiliation(s)
- Harpal S Khanuja
- Center for Joint Preservation and Replacement, The Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, 2401 West Belvedere Avenue, Baltimore, MD 21215, USA.
| | | | | | | |
Collapse
|
23
|
Allen Butler R, Rosenzweig S, Myers L, Barrack RL. The Frank Stinchfield Award: the impact of socioeconomic factors on outcome after THA: a prospective, randomized study. Clin Orthop Relat Res 2011; 469:339-47. [PMID: 20717856 PMCID: PMC3018201 DOI: 10.1007/s11999-010-1519-x] [Citation(s) in RCA: 74] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Most studies of total hip arthroplasty (THA) focus on the effect of the type of implant on the clinical result. Relatively little data are available on the impact of the patient's preoperative status and socioeconomic factors on the clinical results following THA. QUESTIONS/PURPOSES We determined the relative importance of patient preoperative and socioeconomic status compared to implant and technique factors in predicting patient outcome as reflected by scores on commonly utilized rating scales (eg, Harris Hip Score, WOMAC, SF-12, degree of patient satisfaction, or presence or severity of thigh pain) following cementless THA. METHODS All patients during the study period were offered enrollment in a prospective, randomized study to receive either a titanium, tapered, proximally coated stem; or a Co-Cr, cylindrical, extensively coated stem; 102 patients were enrolled. We collected detailed patient data preoperatively including diagnosis, age, gender, insurance status, medical comorbidities, tobacco and alcohol use, household income, educational level, and history of treatment for lumbar spine pathology. Clinical evaluation included Harris Hip Score, SF-12, WOMAC, pain drawing, and UCLA activity rating and satisfaction questionnaire. Implant factors included stem type, stem size, fit in the canal, and stem-bone stiffness ratios. Minimum 2 year followup was obtained in 95% of the enrolled patients (102 patients). RESULTS Patient demographics and preoperative status were more important than implant factors in predicting the presence of thigh pain, dissatisfaction, and a low hip score. The most predictive factors were ethnicity, educational level, poverty level, income, and a low preoperative WOMAC score or preoperative SF-12 mental component score. No implant parameter correlated with outcome or satisfaction. CONCLUSION Socioeconomic factors and preoperative status have more impact on the clinical outcome of cementless THA than implant related factors. LEVEL OF EVIDENCE Level I, prospective, randomized clinical trial. See the guidelines online for a complete description of level of evidence.
Collapse
Affiliation(s)
| | - Seth Rosenzweig
- Dauterive Orthopaedics & Sports Medicine, New Iberia, LA
USA
| | - Leann Myers
- Department of Biostatistics, Tulane University School of Public Health & Tropical Medicine, New Orleans, LA
USA
| | - Robert L. Barrack
- Department of Orthopaedic Surgery, Washington University School of Medicine, One Barnes-Jewish Hospital Plaza, 11300 West Pavilion, St Louis, MO 63110 USA
| |
Collapse
|
24
|
Bachour F, Marchetti E, Bocquet D, Vasseur L, Migaud H, Girard J. Radiographic preoperative templating of extra-offset cemented THA implants: how reliable is it and how does it affect survival? Orthop Traumatol Surg Res 2010; 96:760-8. [PMID: 20851077 DOI: 10.1016/j.otsr.2010.05.004] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/30/2009] [Revised: 04/11/2010] [Accepted: 05/10/2010] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Securing femoral offset should in theory improve hip stability and abductor muscles moment arms. As problems arise mainly in case of originally increased offset (>40 mm), a range of extra-offset stems is available; the exact impact in terms of fixation, however, is not known. HYPOTHESIS Extra-offset stems should more reliably reestablish original femoral offsets exceeding 40 mm than standard femoral components, limiting instability risk without possible adverse effect on fixation. OBJECTIVE To compare the ability of five commonly available femoral stem designs to restitute offset exceeding 40 mm, and to assess function and cement fixation at a minimum 6 years' follow-up in a stem conceived to reproduce such offset. PATIENTS AND METHODS A continuous series of 74 total hip replacements (THR) in hips with increased (>40 mm) femoral offset was studied. All underwent preoperative X-ray templating on Imagika™ software to assess offset reproduction by five models of stem: four standard, and one Lubinus SP2™ extra-offset stem. A retrospective clinical and X-ray study was conducted with a minimum 6 years' follow-up on the Lubinus SP2™ 117° stems used to try to reproduce offset in the 74 THRs. RESULTS Apart from the increased (>40 mm) offset, the cervicodiaphyseal angle was consistently <135°, <130° in 60 femurs (81%) and <125° in 45 (60%). Planning showed the four standard stems to induce (>5mm femoral offset reduction in 50-83% of cases, versus only 25% with the Lubinus SP2™ 117°). All 74 hips received Lubinus SP2™ 117° stems: at a mean 78 months FU (range, 70-94 mo), their mean Postel-Merle d'Aubigné score was 17±1.8 (range, 13-18). Five of the 74 THRs underwent surgical revision: three cases of loosening, in which the stem was replaced, and two of instability, without change of stem. Loosening was not related to offset reproduction quality; two of the three cases were due to initial cementing defect, and the third occurred in a femur with previous history of two osteotomies. There were four cases of dislocation (5.4%: two primary, which were not operated on, and two recurrent, managed by acetabular revision), despite good reproduction of the preoperative offset in three of the four cases. Mean 7-year implant survivorship was 95.1% (±4.8). DISCUSSION AND CONCLUSION The anatomic form of the Lubinus™ SP2 117° should in theory provide a uniform cement mantle. Survivorship, however, is less good than for regular offset versions (126° or 135°). On the other hand, it does reproduce anatomy in case of >40mm offset, providing extra offset of more than 51mm. The slightly shorter survivorship requires more long-term surveillance. LEVEL OF EVIDENCE Level IV, retrospective study.
Collapse
Affiliation(s)
- F Bachour
- Dr Rizk Clinic, BP 113288, Beirut, Lebanon
| | | | | | | | | | | |
Collapse
|
25
|
Mokhtar SA, McCombe PF, Williamson OD, Morgan MK, White GJ, Sears WR. Health-related quality of life: a comparison of outcomes after lumbar fusion for degenerative spondylolisthesis with large joint replacement surgery and population norms. Spine J 2010; 10:306-12. [PMID: 20362246 DOI: 10.1016/j.spinee.2010.01.018] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/24/2009] [Revised: 12/03/2009] [Accepted: 01/20/2010] [Indexed: 02/03/2023]
Abstract
BACKGROUND CONTEXT Degenerative spine disease will become an increasing health problem, and a significant number of patients will be considered for surgery. Spinal surgeries have evolved since the last decades, and there is a positive impact on the clinical outcomes. Few works in the literature have reviewed the outcome compared with large joint replacement surgery, which is considered a benchmark for operative restoration of patients' quality of life. PURPOSE The purpose of this study was to investigate if spinal fusion can return patients' health-related quality of life to that of age-matched population norms and yield outcomes comparable with those of total hip and knee joint replacement. STUDY DESIGN This is a prospective cohort study. PATIENT SAMPLE The sample consists of 100 consecutive patients who were enrolled between December 1997 and January 2007. OUTCOME MEASURES The 12-item Short Form Health Survey (SF-12) was chosen for outcome measurement. METHODS All patients underwent wide decompressive laminectomy and single-level posterior lumbar interbody fusion for spinal stenosis associated with degenerative spondylolisthesis. RESULTS The preoperative and postoperative physical component summary (PCS)-12 scores of the spinal fusion patients were comparable with those of both the total knee and hip replacement patients. The mean improvement in PCS-12 scores after spine surgery was 11 (95% confidence interval [CI]: 9-14, p<.0001). It was equal to that after total hip replacement surgery, which was 11 (95% CI: 9-13), and higher than that of total knee replacement patients, which had an improvement of 8 (95% CI: 7-9). The postoperative mean and 95% CI of the PCS-12 scores for the three surgical procedures approached the population norm value of 44 (95% CI: 43-46).There was no statistical difference between the postoperative mental component summary-12 score among all the three surgical groups, which approached similar to the population norm value of 54 (95% CI: 53-54). CONCLUSIONS The current study demonstrated that spinal surgery can return patients' HRQL to that of age-matched population norms and yield outcomes comparable with those of total hip and knee joint replacement patients.
Collapse
Affiliation(s)
- Sabarul A Mokhtar
- Department of Spinal Surgery, The Australian School of Advanced Medicine, Macquarie University, Sydney, New South Wales 2109, Australia.
| | | | | | | | | | | |
Collapse
|
26
|
Abstract
UNLABELLED There are two broad-based categories of cementless femoral component designs: proximally porous-coated and fully porous-coated. While both have been widely used, there remains debate regarding differences in clinical outcome scores, relative incidence of thigh pain, and development of stress shielding. We investigated these variables in a multicenter prospective randomized blinded clinical trial of 388 patients from three centers: 198 patients had a proximally porous-coated tapered cementless femoral component and 190 patients had a fully porous-coated cementless femoral component. A minimum followup of 2 years (mean, 6.7 years; range, 2.0-8.65 years) was available in 367 of the 388 patients (95%). We observed no differences in age at surgery, body mass index, or preoperative clinical outcome scores (WOMAC, SF-12, Harris hip score, UCLA activity, thigh pain) with the two groups. We determined serial bone density changes in a subcohort of 72 patients from two of the three centers. The postoperative clinical outcome scores were similar at all followup intervals, and we observed no differences in the incidence of thigh pain at any time. Bone density reduction in Gruen Zone 7 was greater with the fully coated stem than the proximally coated stem (24% versus 15% reduction, respectively). Both fully and proximally coated stems performed well, with no clinical differences at 2 years' followup, except in bone mineral density evaluations. LEVEL OF EVIDENCE Level I, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Collapse
|
27
|
Klein GR, Levine HB, Nafash SC, Lamothe HC, Hartzband MA. Total hip arthroplasty with a collarless, tapered, fiber metal proximally coated femoral stem: minimum 5-year follow-up. J Arthroplasty 2009; 24:579-85. [PMID: 18555647 DOI: 10.1016/j.arth.2008.04.010] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/01/2007] [Accepted: 04/06/2008] [Indexed: 02/07/2023] Open
Abstract
The purpose of this study was to evaluate the midterm results, osteointegration potential, and implant-related complications of a cementless, collarless, proximally coated, distally tapered femoral hip prosthesis. The clinical and radiographic results for 129 hips in 116 patients after total hip arthroplasty with a Fiber Metal Taper (Zimmer, Inc ,Warsaw, Ind) femoral stem are reported. One hundred twenty-two (95%) hips were available for the minimum of 5 years clinical and radiographic follow-up. The mean duration of follow-up was 81 months (range, 60-104 months). The mean Harris hip score improved from 44 to 92 at the most recent follow-up. All femoral components were clinically stable with radiographic evidence of bone ingrowth. There has been no evidence of subsidence greater than 2 mm, no significant thigh pain, and no femoral revisions for any reason. Total hip arthroplasty with the Fiber Metal Taper stem demonstrates good clinical and radiographic results at midterm follow-up.
Collapse
Affiliation(s)
- Gregg R Klein
- Hartzband Joint Replacement Institute, Paramus, New Jersey 07652, USA
| | | | | | | | | |
Collapse
|
28
|
Aynardi M, Pulido L, Parvizi J, Sharkey PF, Rothman RH. Early mortality after modern total hip arthroplasty. Clin Orthop Relat Res 2009; 467:213-8. [PMID: 18846410 PMCID: PMC2600973 DOI: 10.1007/s11999-008-0528-5] [Citation(s) in RCA: 68] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/15/2008] [Accepted: 09/09/2008] [Indexed: 01/31/2023]
Abstract
UNLABELLED Because of improvements in surgical technique, anesthesia, and rehabilitation, mortality after hip arthroplasty may be on the decline. The purpose of this study was to determine the 90-day mortality rate after uncemented total hip arthroplasty (THA) performed under regional anesthesia. We retrospectively reviewed 7478 consecutive patients undergoing cementless primary or revision THA between January 2000 and July 2006. Patient survivorship was established and causes of death were obtained by accessing the Social Security Death Index, Centers for Disease Control and Prevention National Death Index, and State Departments of Vital Statistics. There were two intraoperative deaths from cardiac arrest. The overall 30- and 90-day mortality rates were 0.24% (18 of 7478) and 0.55% (41 of 7478), respectively. Thirty-day mortality after primary THA was low at 0.13% (eight of 6272). The most common cause of death was cardiovascular-related. Mortality after modern THA seems to have remained very low despite the availability of this procedure to patients of all ages and comorbidities. LEVEL OF EVIDENCE Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Michael Aynardi
- Rothman Institute of Orthopaedics, Thomas Jefferson University Hospital, 925 Chestnut Street, Philadelphia, PA 19107 USA
| | - Luis Pulido
- Rothman Institute of Orthopaedics, Thomas Jefferson University Hospital, 925 Chestnut Street, Philadelphia, PA 19107 USA
| | - Javad Parvizi
- Rothman Institute of Orthopaedics, Thomas Jefferson University Hospital, 925 Chestnut Street, Philadelphia, PA 19107 USA
| | - Peter F. Sharkey
- Rothman Institute of Orthopaedics, Thomas Jefferson University Hospital, 925 Chestnut Street, Philadelphia, PA 19107 USA
| | - Richard H. Rothman
- Rothman Institute of Orthopaedics, Thomas Jefferson University Hospital, 925 Chestnut Street, Philadelphia, PA 19107 USA
| |
Collapse
|
29
|
Midterm results of the Synergy cementless tapered stem: stress shielding and bone quality. J Orthop Sci 2008; 13:498-503. [PMID: 19089536 DOI: 10.1007/s00776-008-1272-0] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/17/2008] [Accepted: 07/30/2008] [Indexed: 02/09/2023]
Abstract
BACKGROUND Tapered femoral stems have been shown to produce less thigh pain and stress shielding than other cement-less stem designs. The purpose of this study was to examine the performance of this type of femoral stem in Japanese patients. METHODS A series of 40 total hip arthroplasties with a Synergy tapered femoral component were performed in 33 patients between March 1999 and February 2001 at our institution. Three hips (in three patients) were lost to follow-up, so 37 hips in 30 patients were followed for an average of 70 months. The patients' average age at the time of surgery was 59 years (range 43-80 years). Clinical evaluation included the Japanese Orthopaedic Association (JOA) Hip Score and the incidence of thigh pain. Preoperative radiographic examination included the cortical index and Dorr's bone type. Postoperative radiographic examination included evaluation of biological fixation, spot welds, cortical hypertrophy, and stress shielding. RESULTS The average JOA Hip Score improved significantly from 35 preoperatively to 91 postoperatively. No patient suffered thigh pain. All femoral components were classified as bony stable. Spot welds and cortical hypertrophy were commonly found in the middle to the distal portion of the component. Severe (third and fourth degree) stress shielding was observed in 24.3% of the cases. A low cortical index, a Dorr type C femur, and a large stem size were associated with severe stress shielding. CONCLUSIONS The midterm clinical results with the Synergy femoral component were satisfactory for Japanese patients. Although severe stress shielding was frequently observed in patients with poor bone quality, stem stability was not affected. Extent of grit blasting and stem length may be factors causing severe stress shielding in Japanese patients with poor bone quality. In conclusion, poor bone quality is a less favorable indication for the cementless tapered stem.
Collapse
|
30
|
Femoral fit in ABG-II hip stems, influence on clinical outcome and bone remodeling: a radiographic study. Arch Orthop Trauma Surg 2008; 128:1065-72. [PMID: 18058112 DOI: 10.1007/s00402-007-0537-y] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/27/2007] [Indexed: 02/06/2023]
Abstract
INTRODUCTION In a consecutive series of 64 patients with an ABG-II stem, we analyzed whether the tightness of the fit of the prosthesis affected bone remodeling and if there was a relation between clinical and radiological results. MATERIALS AND METHODS Radiographic analysis of bone remodeling in different Gruen zones was done. Bone density changes were graded as present or absent in the AP and lateral radiographs as compared with the previous sets of radiographs. Bone remodeling was compared to literature values of the ABG-I stem. Three stem levels were defined. The proximal level was set at the upper border of the lesser trochanter, the mid-stem level at halfway the stem and the distal level 1 cm above the tip of the prosthesis. Femoral fit was defined as tight when the ratio of the fit was >/=0.8 and as non-tight if the fit was <0.8. The incidence of thigh pain was scored using the Merle d'Aubigne (MdA) hip score. RESULTS Proximal bone resorption in Gruen zone 1 was 26.6% and in zone 7, 34.4% compared to 48 and 45% for the ABG-I stem after 5 years. No correlation was found between femoral fit and radiological changes. Proximal and distal fit was significantly lower for patients with thigh pain than without thigh pain. Patients with a non-tight proximal fit produced significantly more varus (17/30 = 56.7%) than patients with a tight proximal fit (2/34 = 5.9%; P < 0.01). CONCLUSION Femoral fit in ABG-II does not predict certain radiological changes, but less proximal bone resorption confirms the design changes from ABG-I to ABG-II. A non-tight proximal fit is correlated with varus position of the stem. Thigh pain is correlated with a poor fit and fill of the femoral stem.
Collapse
|
31
|
Gross TP, Liu F. Metal-on-metal hip resurfacing with an uncemented femoral component. A seven-year follow-up study. J Bone Joint Surg Am 2008; 90 Suppl 3:32-7. [PMID: 18676934 DOI: 10.2106/jbjs.h.00614] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Metal-on-metal hip resurfacing with hybrid fixation has been introduced as an alternative to standard total hip arthroplasty, especially for young and active patients. There are few studies in the literature on the midterm results of cementless femoral side resurfacing. The purpose of this study was to present our seven-year clinical results of a series of twenty cementless metal-on-metal hip resurfacing procedures. METHODS Between 1999 and 2000, eighteen patients (twenty hips) underwent primary metal-on-metal hip resurfacing with uncemented femoral and acetabular components. One patient was lost to follow-up. This left eleven men and six women, who had a mean age of forty-five years at the time of surgery. Clinical and radiographic examinations were performed prospectively, and the results were analyzed. RESULTS The mean duration of follow-up was 7.4 years. There were four revisions, none of which was due to aseptic failure of the femoral component. Two were due to loosening of the acetabular component, one was due to a late hematogenous infection, and one was due to persistent pain despite normal radiographic findings. The mean preoperative Harris hip score was 54 points, and it increased to 94 points at the time of the last follow-up. Radiographic examination of the hips for which the procedure was successful revealed no femoral or acetabular radiolucencies, no migration of any implant, and no osteolysis. The radiographs of one patient (two hips) showed substantial narrowing of the femoral necks (a mean of 12%), which stabilized at three years postoperatively. This patient had a Harris hip score of 100 points for both hips at six years. CONCLUSIONS This study suggests that cementless femoral fixation may be a viable alternative to fixation with cement in metal-on-metal hip resurfacing. Further study of this concept in larger numbers of patients is warranted.
Collapse
Affiliation(s)
- Thomas P Gross
- Midlands Orthopaedics, 1910 Blanding Street, Columbia, SC 29201, USA.
| | | |
Collapse
|
32
|
Abstract
Impingement is a cause of poor outcomes of prosthetic hip arthroplasty; it can lead to instability, accelerated wear, and unexplained pain. Impingement is influenced by prosthetic design, component position, biomechanical factors, and patient variables. Evidence linking impingement to dislocation and accelerated wear comes from implant retrieval studies. Operative principles that maximize an impingement-free range of motion include correct combined acetabular and femoral anteversion and an optimal head-neck ratio. Operative techniques for preventing impingement include medialization of the cup to avoid component impingement and restoration of hip offset and length to avoid osseous impingement.
Collapse
Affiliation(s)
- Aamer Malik
- The Arthritis Institute, 501 East Hardy Street, 3rd Floor, Inglewood, CA 90301, USA
| | | | | |
Collapse
|