1
|
Huang Y, Zhou Y, Shao H, Yang D, Tang H, Guo S. A Novel Endosteal Reconstruction of the Femur from Distal Femoral Remnant Using 3D-Printed Titanium Rings: A Two-Case Report. JBJS Case Connect 2021; 11:01709767-202109000-00096. [PMID: 34449452 DOI: 10.2106/jbjs.cc.20.01038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
CASE Femur reconstruction with only the distal femoral remnant is challenging because of poor bone volume required for stem fixation. Although proximal femoral replacement, total femur replacement, allograft prosthesis composite, and custom porous tantalum implants are options, hybrid fixation enhanced by endosteal reconstruction with three-dimensional (3D)-printed porous titanium rings to reconstruct the femur without supporting isthmus has not been described. We report 2 cases with satisfactory 34- and 22-month follow-up results of hybrid fixation enhanced by endosteal reconstruction with 3D-printed porous titanium rings. CONCLUSION This novel method provides a solution to revise loosened femoral endoprosthesis with only distal femoral remnant.
Collapse
Affiliation(s)
- Yong Huang
- Department of Orthopaedics, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, China
| | | | | | | | | | | |
Collapse
|
2
|
Singh VA. Commentary: Vascularized bone graft is an effective technique for extra-cortical bone bridging to combat cemented megaprosthesis loosening at the bone-implant junction. J Orthop Surg (Hong Kong) 2021; 28:2309499020972483. [PMID: 33345709 DOI: 10.1177/2309499020972483] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|
3
|
Gee ECA, Eleotério R, Bowker LM, Saithna A, Hunt JA. The influence of tantalum on human cell lineages important for healing in soft-tissue reattachment surgery: an in-vitro analysis. J Exp Orthop 2019; 6:40. [PMID: 31659540 PMCID: PMC6816656 DOI: 10.1186/s40634-019-0210-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/01/2019] [Accepted: 10/17/2019] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Porous tantalum is currently used in orthopaedic surgery for a variety of indications including soft tissue re-attachment. However, the clinical results have been variable and a previous laboratory study has suggested that tantalum may actually inhibit chick tendon fibroblasts. The influence of tantalum on human cell-types involved in soft tissue re-attachment has not been defined. METHODS Human fibroblasts, human osteoblasts and human mesenchymal stem cells were plated on glass cover slips, half of which were coated with tantalum. Cell numbers were assessed at 1, 2, 7 and 14 days using Cyquant® assay. Cell adhesion and morphology were assessed using light microscopy at 7, 14 and 28 days. To reduce the effect of an expected rate of error, n = 4 was utilised for each cell type and the experiment was repeated twice. RESULTS Statistically similar numbers of human osteoblasts and human mesenchymal stem cells were present at 14 days on tantalum-coated and uncoated glass cover slips, revealing no inhibitory effect on cell proliferation. More than double the number of human fibroblasts was seen on tantalum-coated cover slips at that time point (compared to controls), which was statistically significant (p < 0.0001). Morphological assessment revealed normal cell spreading and adhesion on both substrates at all time points. CONCLUSIONS In vitro study demonstrates that Tantalum causes a significant increase in the proliferation of human fibroblasts with no quantifiable negative effects seen on fibroblast behaviour after 28 days culture. Furthermore, tantalum does not exert any inhibitory effects on the proliferation or behaviour of human osteoblasts or human mesenchymal stem cells. Tantalum could be an appropriate biomaterial for use in situations where soft tissue requires direct reattachment to implants and may stimulate soft tissue healing.
Collapse
Affiliation(s)
| | - Renato Eleotério
- School of Science and Technology, Nottingham Trent University, Nottingham, NG11 8NS UK
| | - Laura M. Bowker
- School of Science and Technology, Nottingham Trent University, Nottingham, NG11 8NS UK
| | - Adnan Saithna
- School of Science and Technology, Nottingham Trent University, Nottingham, NG11 8NS UK
- Sano Orthopedic Clinic, Kansas City, Kansas USA
- Kansas City University of Medicine and Biosciences, Kansas City, MO USA
| | - John A. Hunt
- School of Science and Technology, Nottingham Trent University, Nottingham, NG11 8NS UK
| |
Collapse
|
4
|
Causes and Frequencies of Reoperations After Endoprosthetic Reconstructions for Extremity Tumor Surgery: A Systematic Review. Clin Orthop Relat Res 2019; 477:894-902. [PMID: 30801278 PMCID: PMC6437378 DOI: 10.1097/corr.0000000000000630] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Excision of bone tumors and endoprosthetic reconstruction allow patients early weightbearing and a potential functional advantage compared with amputation. These reconstructions do not restore the limb to normal status, however, and patients are subject to complications that may result in revision or loss of the limb. Because better understanding of these complications based on current information might help the patient and surgeon in decision-making, we undertook a systematic review of studies published on this topic. QUESTIONS/PURPOSES (1) What are the primary modes and proportion of failure of tumor endoprostheses in patients undergoing reconstruction after excision of primary extremity bone sarcomas? METHODS We systematically searched MEDLINE, Embase, and the Cochrane Library for all studies published from April 15, 1998, to April 15, 2018. Three reviewers independently reviewed studies reporting endoprosthetic reconstruction survival and events requiring revision for primary extremity bone tumors treated with endoprosthetic reconstruction for inclusion and performed independent data extraction. We excluded all studies with fewer than five patients, any systematic review/meta-analyses, and any study not reporting on primary extremity bone tumors. All discrepancies were resolved by the study's senior author. Data extracted from included studies were any reoperation event for wound dehiscence, any operative fixation for a pathologic fracture, and any revision of the primary endoprosthesis for implant wear or breakage, deep infection not amenable to prosthesis retention, or for local recurrence. We assessed the overall quality of the evidence with the Methodological Index for Non-Randomized Studies (MINORS) approach with a higher MINORS score representative of a more methodologically rigorous study with a total possible score of 16 points for noncomparative and 24 points for comparative studies. Forty-nine studies met criteria for inclusion from an initial search return of 904 studies, of which no studies were randomized controlled trials. From a total patient population of 2721, there was a mean followup of 93 months (range, 1-516 months) with loss to followup or death occurring in 447 of 2118 (21%) patients with six studies not providing loss to followup data. The mean MINORS score was 14 for prospective studies and 11 for retrospective studies. RESULTS Overall, there were 1283 reoperations among the 2721 (47%) patients. Reoperation for mechanical endoprosthetic events (soft tissue dehiscence or periarticular soft tissue instability, aseptic loosening, or implant wear/fracture) occurred in 907 of 2721 (33%) patients. Aseptic loosening occurred at a mean of 75 months (range, 1-376 months) in 212 of 315 patients (67%). Deep infection requiring removal of the initial prosthesis occurred in 247 of 2721 (9%) patients with deep infection occurring at a mean of 24 months (range, 1-372 months) in the 190 infections (77%) with time to infection data available. Local recurrence rates requiring revision or amputation occurred in 129 (5%) of all patients. There was an overall primary endoprosthesis survival rate without any surgical reintervention of 63% among reporting studies at a mean of 79 months followup. CONCLUSIONS Failures of endoprosthetic reconstructions after extremity tumor surgery are common, most often resulting from implant wear or fracture, aseptic loosening, and infection. Importantly, the aggregated data are the first to attempt to quantify the time to specific complication types within this patient population. Deep infection not amenable to endoprosthesis retention appears to occur approximately 2 years postoperatively in most patients, with aseptic loosening occurring most commonly at 75 months. Although endoprosthetic reconstruction is one of the most common forms of reconstruction after bone tumor resection, the quality of published evidence regarding this procedure is of low quality with high loss to followup and data quality limiting interstudy analysis. The quality of the evidence is low with high loss to followup and inconsistent reporting of times to reintervention events. Although the most common modes of endoprosthetic failure in this population are well known, creation of quality prospective, collaborative databases would assist in clarifying and informing important elements of the followup process for these patients. LEVEL OF EVIDENCE Level IV, therapeutic study.
Collapse
|
5
|
Sowa M, Simka W. Electrochemical Impedance and Polarization Corrosion Studies of Tantalum Surface Modified by DC Plasma Electrolytic Oxidation. MATERIALS 2018; 11:ma11040545. [PMID: 29614014 PMCID: PMC5951429 DOI: 10.3390/ma11040545] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/09/2018] [Revised: 03/25/2018] [Accepted: 04/02/2018] [Indexed: 01/10/2023]
Abstract
Tantalum has recently become an actively researched biomaterial for the bone reconstruction applications because of its excellent corrosion resistance and successful clinical records. However, a bare Ta surface is not capable of directly bonding to the bone upon implantation and requires some method of bioactivation. In this study, this was realized by direct current (DC) plasma electrolytic oxidation (PEO). Susceptibility to corrosion is a major factor determining the service-life of an implant. Therefore, herein, the corrosion resistance of the PEO coatings on Ta was investigated in Ringer’s solution. The coatings were formed by galvanostatic anodization up to 200, 300 and 400 V, after which the treatment was conducted potentiostatically until the total process time amounted to 5 min. Three solutions containing Ca(H2PO2)2, Ca(HCOO)2 and Mg(CH3COO)2 were used in the treatment. For the corrosion characterization, electrochemical impedance spectroscopy and potentiodynamic polarization techniques were chosen. The coatings showed the best corrosion resistance at voltages low enough so that the intensive sparking was absent, which resulted in the formation of thin films. The impedance data were fitted to the equivalent electrical circuits with two time constants, namely R(Q[R(QR)]) and R(Q[R(Q[RW])]). The inclusion of W in the circuit helped to fit the low-frequency part of the samples PEO-ed at 400 V, hinting at the important role of diffusion in the corrosion resistance of the PEO coatings described in the research.
Collapse
Affiliation(s)
- Maciej Sowa
- Faculty of Chemistry, Silesian University of Technology, B. Krzywoustego Street 6, 44-100 Gliwice, Poland.
| | - Wojciech Simka
- Faculty of Chemistry, Silesian University of Technology, B. Krzywoustego Street 6, 44-100 Gliwice, Poland.
| |
Collapse
|
6
|
Groundland JS, Ambler SB, Houskamp LDJ, Orriola JJ, Binitie OT, Letson GD. Surgical and Functional Outcomes After Limb-Preservation Surgery for Tumor in Pediatric Patients: A Systematic Review. JBJS Rev 2018; 4:01874474-201602000-00002. [PMID: 27490132 DOI: 10.2106/jbjs.rvw.o.00013] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
BACKGROUND Limb-salvage surgery and segmental reconstruction for the treatment of lower extremity osseous tumors in the pediatric population have been described in the literature, but there is little consensus regarding the optimal surgical treatment for this patient population. METHODS A systematic review of the literature was performed to identify studies focusing on limb-salvage procedures in pediatric patients who were managed with one of three reconstructions with use of a metallic endoprosthesis, allograft, or allograft-prosthesis composite. Data were segregated according to the excised and reconstructed anatomical location (proximal part of the femur, total femur, distal part of the femur, proximal part of the tibia) and were collated to assess modes of failure and functional outcomes of each reconstruction type for each anatomic location. RESULTS Sixty articles met the inclusion criteria; all were Level-IV evidence, primarily consisting of small, retrospective case series. Infection was a primary mode of failure across all reconstruction types and locations, whereas allograft reconstructions were susceptible to structural failure as well. The rate of failure in the pediatric population correlated well with previously published results for adults. The incidence of subsequent amputation was lower in the pediatric population (5.2%) than has been reported in adults (9.5%) (p = 0.013). Meaningful growth of expandable metallic endoprostheses was reported in the literature, with an overall rate of leg-length discrepancy of 13.4% being noted at the time of the latest follow-up. The Musculoskeletal Tumor Society (MSTS) questionnaire was the most consistently used outcome measure in the literature, with average scores ranging from 71.0% to 86.8%, depending on reconstruction type and anatomic location. CONCLUSIONS The current state of the literature detailing the surgical and functional outcomes of segmental reconstruction for the treatment of pediatric bone tumors is limited to Level-IV evidence and is complicated by under-segregation of the data by age and anatomical location of the reconstruction. Despite these limitations, pediatric limb-salvage surgery demonstrates satisfactory initial surgical and functional outcomes. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- John S Groundland
- Department of Orthopedics and Sports Medicine (J.S.G.), School of Physical Therapy & Rehabilitation Sciences (S.B.A), Shimberg Health Sciences Library (J.J.O.), USF Health Morsani College of Medicine, University of South Florida, 13330 USF Laurel Drive, MDC 90, Tampa, FL 33612
| | - Steven B Ambler
- Department of Orthopedics and Sports Medicine (J.S.G.), School of Physical Therapy & Rehabilitation Sciences (S.B.A), Shimberg Health Sciences Library (J.J.O.), USF Health Morsani College of Medicine, University of South Florida, 13330 USF Laurel Drive, MDC 90, Tampa, FL 33612
| | - Lt Daniel J Houskamp
- Department of Orthopaedic Surgery, Naval Medical Center San Diego, 34800 Bob Wilson Drive, San Diego, CA 92134
| | - John J Orriola
- Department of Orthopedics and Sports Medicine (J.S.G.), School of Physical Therapy & Rehabilitation Sciences (S.B.A), Shimberg Health Sciences Library (J.J.O.), USF Health Morsani College of Medicine, University of South Florida, 13330 USF Laurel Drive, MDC 90, Tampa, FL 33612
| | - Odion T Binitie
- Sarcoma Department (O.T.B.) and Executive Vice President of Clinical Affairs (G.D.L.), H. Lee Moffitt Cancer Center, 12902 Magnolia Drive, Tampa, FL 33612
| | - G Douglas Letson
- Sarcoma Department (O.T.B.) and Executive Vice President of Clinical Affairs (G.D.L.), H. Lee Moffitt Cancer Center, 12902 Magnolia Drive, Tampa, FL 33612
| |
Collapse
|
7
|
Wang C, Wang Y, Meng H, Wang X, Zhu Y, Yu K, Yuan X, Wang A, Guo Q, Peng J, Lu S. Research progress regarding nanohydroxyapatite and its composite biomaterials in bone defect repair. INT J POLYM MATER PO 2016. [DOI: 10.1080/00914037.2016.1149849] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
8
|
Gee ECA, Jordan R, Hunt JA, Saithna A. Current evidence and future directions for research into the use of tantalum in soft tissue re-attachment surgery. J Mater Chem B 2016; 4:1020-1034. [DOI: 10.1039/c5tb01786f] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
The use of tantalum is well established in orthopaedic surgery.
Collapse
Affiliation(s)
- Edward C. A. Gee
- Southport and Ormskirk Hospitals
- Orthopaedics
- Southport
- United Kingdom of Great Britain and Northern Ireland
| | - Robert Jordan
- Southport and Ormskirk Hospitals
- Orthopaedics
- Southport
- United Kingdom of Great Britain and Northern Ireland
| | - John A. Hunt
- University of Liverpool
- Clinical Engineering
- Duncan Building
- Daulby Street
- Liverpool
| | - Adnan Saithna
- Southport and Ormskirk Hospitals
- Orthopaedics
- Southport
- United Kingdom of Great Britain and Northern Ireland
| |
Collapse
|
9
|
Tischler EH, Hansen E, Austin MS. A Custom Trabecular Metal Implant in Revision Total Hip Replacement with a Paprosky Type-IV Femoral Defect: A Case Report. JBJS Case Connect 2014; 4:e103. [PMID: 29252771 DOI: 10.2106/jbjs.cc.n.00018] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
CASE Treatment for severe femoral bone defects involving loss of the supporting isthmus is limited. Techniques are based on surgeon experience and patient-related factors. Revision arthroplasty can be challenging depending on bone loss and quality. Highly porous metals, such as trabecular metal, are ideal alternatives for complex reconstruction; however, little has been written about trabecular metal for reconstruction of the proximal part of the femur. CONCLUSION We report the five-year midterm results of a custom trabecular metal implant for a Paprosky type-IV femoral defect. This novel construct provides durable midterm survivorship and excellent function for Paprosky type-IV femoral bone loss.
Collapse
Affiliation(s)
- Eric H Tischler
- Rothman Institute at Thomas Jefferson Hospital, Thomas Jefferson University, 925 Chestnut Street, 5th Floor, Philadelphia, PA 19107.
| | | | | |
Collapse
|
10
|
Thambapillary S, Dimitriou R, Makridis KG, Fragkakis EM, Bobak P, Giannoudis PV. Implant longevity, complications and functional outcome following proximal femoral arthroplasty for musculoskeletal tumors: a systematic review. J Arthroplasty 2013; 28:1381-5. [PMID: 23523494 DOI: 10.1016/j.arth.2012.10.024] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/25/2012] [Accepted: 10/26/2012] [Indexed: 02/01/2023] Open
Abstract
A systematic review of the literature was undertaken to evaluate the outcomes and complications following proximal femoral arthroplasty for primary or metastatic tumors affecting the proximal femur. Six hundred sixty-eight patients were available for review. The length of resection ranged from 92 to 212 mm. Limb salvage rate reached over 90%. At 5 years the implant survival rate was 84% and at 10 years, it was 70%. The overall revision rate was 11.1%. Prevalence of venous thrombo-embolic (VTE) events was 8.5%, dislocation rate was 5.8%, infection was 5.2%, local tumor reoccurrence was 4.7%, perioperative mortality was 1.5%, and periprosthetic fracture was 0.6%. Where it was provided the Musculoskeletal Tumour Score was 70.8%. The implants tend to outlive patients with metastatic disease and high-grade localized disease, providing them with a relatively pain-free limb with good mobility and quality of life.
Collapse
Affiliation(s)
- Sivaharan Thambapillary
- Academic Department of Trauma and Orthopaedics, School of Medicine, University of Leeds, Leeds General Infirmary, Clarendon wing Level A, Leeds, UK
| | | | | | | | | | | |
Collapse
|
11
|
Porous tantalum coatings prepared by vacuum plasma spraying enhance bmscs osteogenic differentiation and bone regeneration in vitro and in vivo. PLoS One 2013; 8:e66263. [PMID: 23776648 PMCID: PMC3679049 DOI: 10.1371/journal.pone.0066263] [Citation(s) in RCA: 50] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2013] [Accepted: 05/02/2013] [Indexed: 12/01/2022] Open
Abstract
Tantalum, as a potential metallic implant biomaterial, is attracting more and more attention because of its excellent anticorrosion and biocompatibility. However, its significantly high elastic modulus and large mechanical incompatibility with bone tissue make it unsuitable for load-bearing implants. In this study, porous tantalum coatings were first successfully fabricated on titanium substrates by vacuum plasma spraying (VPS), which would exert the excellent biocompatibility of tantalum and alleviate the elastic modulus of tantalum for bone tissue. We evaluated cytocompatibility and osteogenesis activity of the porous tantalum coatings using human bone marrow stromal cells (hBMSCs) and its ability to repair rabbit femur bone defects. The morphology and actin cytoskeletons of hBMSCs were observed via electron microscopy and confocal, and the cell viability, proliferation and osteogenic differentiation potential of hBMSCs were examined quantitatively by PrestoBlue assay, Ki67 immunofluorescence assay, real-time PCR technology and ALP staining. For in vivo detection, the repaired femur were evaluated by histomorphology and double fluorescence labeling 3 months postoperation. Porous tantalum coating surfaces promoted hBMSCs adhesion, proliferation, osteogenesis activity and had better osseointegration and faster new bone formation rate than titanium coating control. Our observation suggested that the porous tantalum coatings had good biocompatibility and could enhance osseoinductivity in vitro and promote new bone formation in vivo. The porous tantalum coatings prepared by VPS is a promising strategy for bone regeneration.
Collapse
|
12
|
Huot Carlson JC, Van Citters DW, Currier JH, Bryant AM, Mayor MB, Collier JP. Femoral stem fracture and in vivo corrosion of retrieved modular femoral hips. J Arthroplasty 2012; 27:1389-1396.e1. [PMID: 22209042 DOI: 10.1016/j.arth.2011.11.007] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2011] [Accepted: 11/21/2011] [Indexed: 02/01/2023] Open
Abstract
A series of 78 retrieved modular hip devices were assessed for fretting and corrosion. Damage was common at both the head-neck junction (54% showing corrosion; 88% showing fretting) and at the stem-sleeve junction (88% corrosion; 65% fretting). Corrosion correlated to in vivo duration, patient activity, and metal (vs ceramic) femoral heads but did not correlate to head carbon content. Femoral stem fatigue fracture was observed in seven retrievals; all had severe corrosion, were under increased stress, and were in vivo longer than the non-fractured cohort. This study emphasizes the potential for stem fracture when small diameter femoral stems with large offsets are used in heavy and active patients. Designs which reduce fretting and corrosion in modular implants is warranted as patients demand longer lasting implants.
Collapse
|
13
|
Duan Y, Liu L, Wang L, Guo F, Li H, Shi L, Li M, Yin D, Jiang C, Zhu Q. Preliminary study of the biomechanical behavior and physical characteristics of tantalum (Ta)-coated prostheses. J Orthop Sci 2012; 17:173-85. [PMID: 22234374 DOI: 10.1007/s00776-011-0191-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/09/2011] [Accepted: 12/12/2011] [Indexed: 01/19/2023]
Abstract
BACKGROUND Use of Ta biomaterials in medicine started in the middle of the last century. The good biocompatibility and chemical stability, and the unique physical characteristics of Ta metal have resulted in many possible developments of Ta biomaterials. METHODS In this study, histopathological observation, histomorphometric analysis, scanning electron microscope (SEM) observation, energy-dispersive X-ray spectroscopy (EDX) analysis, biomechanical testing, and examination of the coating's mechanical strength have been used to evaluate the value of clinical application of Ta-coated prostheses prepared by a plasma-spraying process. RESULTS Histopathological observation has demonstrated that the periprosthetic new bone tissues tightly and stably adhere to the Ta coating after the implantation, with no signs of loosening. Early after implantation, there is no significant difference in periprosthetic bone volume and ultimate shear strength between Ta-coated and Ti-coated prostheses (P > 0.05). EDX analysis suggests that the ultimate shear stress does not damage Ta coating. Mechanical strength testing shows that the adhesive strength and Vicker's surface hardness (HV) of the Ta coating are significantly higher than those of the Ti coating (P < 0.01). CONCLUSIONS Ta coating has good stability and bone biocompatibility; the extraordinary physical characteristics of Ta coating have great significance in maintaining prosthetic stability and surface porosity after implantation.
Collapse
Affiliation(s)
- Yonghong Duan
- Orthopedic Institute of Chinese People's Liberation Army, Xijing Hospital, Fourth Military Medical University, Xi'an, Shaanxi, People's Republic of China
| | | | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Venzin C, Grundmann S, Montavon PM. Loss of implant-bone interface following distal radial locking-plate endoprosthesis limb-sparing surgery in a dog. J Small Anim Pract 2011; 53:57-62. [PMID: 22098022 DOI: 10.1111/j.1748-5827.2011.01141.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
An eight-year-old, neutered female Rottweiler was presented with lameness of seven days duration. Radiographs were consistent with a distal radial bone tumour. Limb-sparing surgery was performed using a commercially available endoprosthesis with a locking bone plate. Histopathological examination of the resected bone revealed an intraosseous fibrosarcoma, and postoperative adjuvant chemotherapy was initiated three weeks after surgery. Despite initial satisfactory limb function, lameness worsened four months after surgery. Radiographs revealed large areas of bone lysis around the proximal and distal screws, leading to significant resorption of the radius and radial carpal bone with subsequent construct failure. Further treatment was declined by the owner and the dog was subsequently euthanased. This case illustrates that implant failure is not necessarily averted by the use of locking (compared with non-locking) implants combined with an endoprosthesis to treat distal radial tumours in dogs.
Collapse
Affiliation(s)
- C Venzin
- Clinic of Small Animal Surgery, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland
| | | | | |
Collapse
|
15
|
Palumbo BT, Henderson ER, Groundland JS, Cheong D, Pala E, Letson GD, Ruggieri P. Advances in segmental endoprosthetic reconstruction for extremity tumors: a review of contemporary designs and techniques. Cancer Control 2011; 18:160-70. [PMID: 21666578 DOI: 10.1177/107327481101800303] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND Improved understanding and advances in treatment regimens have led to increased longevity among patients diagnosed with extremity soft tissue sarcomas. Limb salvage techniques and implants have improved and continue to evolve to accommodate the increasing demands and survival of these patients. METHODS The current report is a review of the literature for recent advancements in techniques, implant design, and outcomes in the field of limb salvage therapy using segmental megaprostheses for the treatment of extremity sarcomas. We report on our experience in this field utilizing a classification system of failure mechanisms to outline to discuss current controversies in management. RESULTS Five mechanisms of failure have been identified: soft-tissue failure, aseptic loosening, structural failure, infection, and tumor progression. Infection was the most common mode of failure in our series, accounting for 34% of cases. Soft-tissue failure occurred most commonly in the joints that depend heavily on periarticular muscles and ligaments for stability due to their high degree of functional range of motion. We observed a 28% soft-tissue failure rate about the shoulder and hip, aseptic loosening accounted for 19% of implant failures, and structural failure was seen in 17% of cases. Seventeen percent of cases failed due to tumor progression, an etiology that is defined by biological factors, surgical technique, and adjuvant therapies. CONCLUSIONS Surgical techniques and megaprosthesis designs are constantly changing in order to meet the challenge of increasing functional demands and longevity in this unique patient population. A classification system defined by treatment failure etiologies provides the framework for discussion of current controversies in limb salvage therapy as well as a guide for advancement and potential solutions in this challenging arena.
Collapse
Affiliation(s)
- Brian T Palumbo
- Department of Orthopaedic Surgery, University of South Florida, Tampa 33620, USA.
| | | | | | | | | | | | | |
Collapse
|