1
|
Cohort analysis of two thousand nine hundred forty-three Link Lubinus SP II cemented total hip arthroplasties from a single hospital with surgeon stratification and twenty six thousand, nine hundred and eighty one component-years of follow-up. INTERNATIONAL ORTHOPAEDICS 2022; 46:797-804. [DOI: 10.1007/s00264-022-05315-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Accepted: 01/18/2022] [Indexed: 11/26/2022]
|
2
|
Shareghi B, Mohaddes M, Kärrholm J. Pelvic tilt between supine and standing after total hip arthroplasty an RSA up to seven years after the operation. J Orthop Res 2021; 39:121-129. [PMID: 32484957 DOI: 10.1002/jor.24759] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2020] [Revised: 05/07/2020] [Accepted: 05/11/2020] [Indexed: 02/04/2023]
Abstract
The pose of the prosthetic components after total hip arthroplasty (THA) is commonly evaluated on conventional radiographs. Any change of the pelvic position after the operation in supine and between supine and standing position with time will influence validity of the measurements. We evaluated the changed pelvic tilt angle (PTA) in supine and standing position up to 7 years after operation. The aims of our study were (a) to evaluate if the PTA change over time after THA, (b) to assess any difference in PTA between supine and standing positions, and (c) to investigate whether factors such as gender, the condition of the opposite hip or low-back pain have any influence on PTA after THA. Repeated radiostereophotogrammetric radiographs of 106 patients were studied. Patients had been examined in the supine position postoperatively, and in both supine and standing positions at 6 months and 7-year follow-up. Measurements of supine patients showed an increasing mean posterior pelvic tilt over time. From supine to standing, the pelvis tilted in the opposite direction. At 6 months, the mean anterior tilt was 3.6° ± 3.8° (confidence interval [CI]: 2.8° to 4.3°) which increased to 6.4° ± 3.9° (CI: 5.7° to 7.2°) at 7 years. The mean changes in pelvic rotations around the longitudinal and sagittal axis were less than 1 degree, in both positions. In individual patients, this change reached about 11.0 degrees in supine and 18.0 degrees when standing.
Collapse
Affiliation(s)
- Bita Shareghi
- Department of Orthopaedics, The Sahlgrenska Academy, Institute of Clinical Sciences, University of Gothenburg, Gothenburg, Sweden
| | - Maziar Mohaddes
- Department of Orthopaedics, The Sahlgrenska Academy, Institute of Clinical Sciences, University of Gothenburg, Gothenburg, Sweden
| | - Johan Kärrholm
- Department of Orthopaedics, The Sahlgrenska Academy, Institute of Clinical Sciences, University of Gothenburg, Gothenburg, Sweden
| |
Collapse
|
3
|
Increased risk for postoperative periprosthetic fracture in hip fracture patients with the Exeter stem than the anatomic SP2 Lubinus stem. Eur J Trauma Emerg Surg 2019; 47:803-809. [PMID: 31740996 PMCID: PMC8187181 DOI: 10.1007/s00068-019-01263-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2019] [Accepted: 11/11/2019] [Indexed: 11/08/2022]
Abstract
Background The purpose of this study was to compare the cumulative incidence of postoperative periprosthetic fracture (PPF) in a cohort of femoral neck fracture (FNF) patients treated with two commonly used cemented stems: either a collarless, polished, tapered Exeter stem or the anatomic Lubinus SP2 stem. Methods In this retrospective multicenter cohort study of a consecutive series of patients, we included 2528 patients of age 60 years and above with an FNF who were treated with either hemiarthroplasty or total hip arthroplasty using either a polished tapered Exeter stem or an anatomic Lubinus SP2 stem. The incidence of PPF was assessed at a minimum of 2 years postoperatively. Results The incidence of PPF was assessed at a median follow-up of 47 months postoperatively. Thirty nine patients (1.5%) sustained a PPF at a median of 27 months (range 0–96 months) postoperatively. Two of the operatively treated fractures were Vancouver A (5%), 7 were Vancouver B1 (18%), 10 were Vancouver B2 (26%), 7 were Vancouver B3 (18%), and 13 were Vancouver C (32%). The cumulative incidence of PPF was 2.3% in the Exeter group compared with 0.7% in the SP2 group (p < 0.001). The HR was 5.4 (95% CI 2.4–12.5, p < 0.001), using the SP2 group as the denominator. Conclusions The Exeter stem was associated with a higher risk for PPF than the Lubinus SP2 stem. We suggest that the tapered Exeter stem should be used with caution in the treatment of FNF. Trial registration The study was registered at clinicaltrials.gov (identifier: NCT03326271).
Collapse
|
4
|
Clarke A, Pulikottil-Jacob R, Grove A, Freeman K, Mistry H, Tsertsvadze A, Connock M, Court R, Kandala NB, Costa M, Suri G, Metcalfe D, Crowther M, Morrow S, Johnson S, Sutcliffe P. Total hip replacement and surface replacement for the treatment of pain and disability resulting from end-stage arthritis of the hip (review of technology appraisal guidance 2 and 44): systematic review and economic evaluation. Health Technol Assess 2015; 19:1-668, vii-viii. [PMID: 25634033 DOI: 10.3310/hta19100] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND Total hip replacement (THR) involves the replacement of a damaged hip joint with an artificial hip prosthesis. Resurfacing arthroplasty (RS) involves replacement of the joint surface of the femoral head with a metal surface covering. OBJECTIVES To undertake clinical effectiveness and cost-effectiveness analysis of different types of THR and RS for the treatment of pain and disability in people with end-stage arthritis of the hip, in particular to compare the clinical effectiveness and cost-effectiveness of (1) different types of primary THR and RS for people in whom both procedures are suitable and (2) different types of primary THR for people who are not suitable for hip RS. DATA SOURCES Electronic databases including MEDLINE, EMBASE, The Cochrane Library, Current Controlled Trials and UK Clinical Research Network (UKCRN) Portfolio Database were searched in December 2012, with searches limited to publications from 2008 and sample sizes of ≥ 100 participants. Reference lists and websites of manufacturers and professional organisations were also screened. REVIEW METHODS Systematic reviews of the literature were undertaken to appraise the clinical effectiveness and cost-effectiveness of different types of THR and RS for people with end-stage arthritis of the hip. Included randomised controlled trials (RCTs) and systematic reviews were data extracted and risk of bias and methodological quality were independently assessed by two reviewers using the Cochrane Collaboration risk of bias tool and the Assessment of Multiple Systematic Reviews (AMSTAR) tool. A Markov multistate model was developed for the economic evaluation of the technologies. Sensitivity analyses stratified by sex and controlled for age were carried out to assess the robustness of the results. RESULTS A total of 2469 records were screened of which 37 were included, representing 16 RCTs and eight systematic reviews. The mean post-THR Harris Hip Score measured at different follow-up times (from 6 months to 10 years) did not differ between THR groups, including between cross-linked polyethylene and traditional polyethylene cup liners (pooled mean difference 2.29, 95% confidence interval -0.88 to 5.45). Five systematic reviews reported evidence on different types of THR (cemented vs. cementless cup fixation and implant articulation materials) but these reviews were inconclusive. Eleven cost-effectiveness studies were included; four provided relevant cost and utility data for the model. Thirty registry studies were included, with no studies reporting better implant survival for RS than for all types of THR. For all analyses, mean costs for RS were higher than those for THR and mean quality-adjusted life-years (QALYs) were lower. The incremental cost-effectiveness ratio for RS was dominated by THR, that is, THR was cheaper and more effective than RS (for a lifetime horizon in the base-case analysis, the incremental cost of RS was £11,284 and the incremental QALYs were -0.0879). For all age and sex groups RS remained clearly dominated by THR. Cost-effectiveness acceptability curves showed that, for all patients, THR was almost 100% cost-effective at any willingness-to-pay level. There were age and sex differences in the populations with different types of THR and variations in revision rates (from 1.6% to 3.5% at 9 years). For the base-case analysis, for all age and sex groups and a lifetime horizon, mean costs for category E (cemented components with a polyethylene-on-ceramic articulation) were slightly lower and mean QALYs for category E were slightly higher than those for all other THR categories in both deterministic and probabilistic analyses. Hence, category E dominated the other four categories. Sensitivity analysis using an age- and sex-adjusted log-normal model demonstrated that, over a lifetime horizon and at a willingness-to-pay threshold of £20,000 per QALY, categories A and E were equally likely (50%) to be cost-effective. LIMITATIONS A large proportion of the included studies were inconclusive because of poor reporting, missing data, inconsistent results and/or great uncertainty in the treatment effect estimates. This warrants cautious interpretation of the findings. The evidence on complications was scarce, which may be because of the absence or rarity of these events or because of under-reporting. The poor reporting meant that it was not possible to explore contextual factors that might have influenced study results and also reduced the applicability of the findings to routine clinical practice in the UK. The scope of the review was limited to evidence published in English in 2008 or later, which could be interpreted as a weakness; however, systematic reviews would provide summary evidence for studies published before 2008. CONCLUSIONS Compared with THR, revision rates for RS were higher, mean costs for RS were higher and mean QALYs gained were lower; RS was dominated by THR. Similar results were obtained in the deterministic and probabilistic analyses and for all age and sex groups THR was almost 100% cost-effective at any willingness-to-pay level. Revision rates for all types of THR were low. Category A THR (cemented components with a polyethylene-on-metal articulation) was more cost-effective for older age groups. However, across all age-sex groups combined, the mean cost for category E THR (cemented components with a polyethylene-on-ceramic articulation) was slightly lower and the mean QALYs gained were slightly higher. Category E therefore dominated the other four categories. Certain types of THR appeared to confer some benefit, including larger femoral head sizes, use of a cemented cup, use of a cross-linked polyethylene cup liner and a ceramic-on-ceramic as opposed to a metal-on-polyethylene articulation. Further RCTs with long-term follow-up are needed. STUDY REGISTRATION This study is registered as PROSPERO CRD42013003924. FUNDING The National Institute for Health Research Health Technology Assessment programme.
Collapse
Affiliation(s)
- Aileen Clarke
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | | | - Amy Grove
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - Karoline Freeman
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - Hema Mistry
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | | | - Martin Connock
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - Rachel Court
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | | | - Matthew Costa
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - Gaurav Suri
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - David Metcalfe
- Warwick Orthopaedics, University Hospitals Coventry and Warwickshire, Coventry, UK
| | - Michael Crowther
- Department of Health Sciences, University of Leicester, Leicester, UK
| | - Sarah Morrow
- Oxford Medical School, University of Oxford, Oxford, UK
| | - Samantha Johnson
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| | - Paul Sutcliffe
- Warwick Evidence, Warwick Medical School, University of Warwick, Coventry, UK
| |
Collapse
|
5
|
The predictive value of radiostereometric analysis for stem survival in total hip arthroplasty. A systematic review. Hip Int 2015; 24:215-22. [PMID: 24474413 DOI: 10.5301/hipint.5000102] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 08/08/2013] [Indexed: 02/04/2023]
Abstract
BACKGROUND The high precision of radiostereometric analysis (RSA) has enabled us to predict long-term implant survival with a small sample of patients followed for a relatively short period of time. The purpose of our systematic review was to validate the predictive value of two-year RSA results on long-term survival of different types of primary total hip arthroplasty stems. METHODS We systematically reviewed literature to determine the maximum total point motion (MTPM), distal migration and rotation of stem designs and correlated these values to survival rates for aseptic loosening of these specific stems in arthroplasty registries. RESULTS We included 32 studies describing migration of 15 different stem designs. The mean MTPM for straight polished cemented stems was 1.35 mm, for other cemented stems 0.83 mm and for other uncemented stems 1.50 mm. No data were available for the uncemented collared stem. Mean distal migration for straight polished cemented stems was 1.24 mm, for other cemented stems 0.26 mm, the uncemented collared stem 0.40 mm and for other uncemented stems 0.66 mm. Internal rotation was presented for 13 stems and all stems rotated into retroversion. All stems showed 10-year survival rates of >97% corrected for aseptic loosening. DISCUSSION Reporting RSA results in a universal way including interpretation of outliers could improve the predictive value of RSA, allowing this technique to be an important tool during the phased introduction of new implant designs. However, a quality assessment of the data by an experienced reviewer is essential.
Collapse
|
6
|
Thien TM, Chatziagorou G, Garellick G, Furnes O, Havelin LI, Mäkelä K, Overgaard S, Pedersen A, Eskelinen A, Pulkkinen P, Kärrholm J. Periprosthetic femoral fracture within two years after total hip replacement: analysis of 437,629 operations in the nordic arthroplasty register association database. J Bone Joint Surg Am 2014; 96:e167. [PMID: 25274795 DOI: 10.2106/jbjs.m.00643] [Citation(s) in RCA: 162] [Impact Index Per Article: 16.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND We used the Nordic Arthroplasty Register Association database to evaluate whether age, sex, preoperative diagnosis, fixation, and implant design influence the risk of revision arthroplasty due to periprosthetic fracture within two years from operation of a primary total hip replacement. METHODS Included in the study were 325,730 cemented femoral stems and 111,899 uncemented femoral stems inserted from 1995 to 2009. Seven frequently used stems (two cemented stems [Exeter and Lubinus SP II] and five uncemented stems [Bi-Metric, Corail, CLS Spotorno, ABG I, and ABG II]) were specifically studied. RESULTS The incidence of revision at two years was low: 0.47% for uncemented stems and 0.07% for cemented stems. Uncemented stems were much more likely to have this complication (relative risk, 8.72 [95% confidence interval, 7.37 to 10.32]; p < 0.0005). Age had no consistent influence on the risk for revision of cemented stems, but revision in the uncemented group increased with increasing age. A cemented stem was associated with a higher risk in male patients compared with female patients (hazard ratio, 1.95 [95% confidence interval, 1.51 to 2.53]; p < 0.0005), whereas an uncemented stem was associated with a reduced risk in male patients compared with female patients (hazard ratio, 0.74 [95% confidence interval, 0.62 to 0.89]; p = 0.001). The risk for revision due to early periprosthetic fracture increased during the 2003 to 2009 period compared with the 1995 to 2002 period both before and after adjustment for demographic factors and fixation (relative risk, 1.44 [95% confidence interval, 1.18 to 1.69]; p < 0.0005). The hazard ratio for the Exeter stem was about five times higher than that for the Lubinus SP II stem (hazard ratio, 5.03 [95% confidence interval, 3.29 to 7.70]; p < 0.0005). Of the five uncemented stems, the ABG II stem showed an increased hazard ratio of 1.63 (95% confidence interval, 1.16 to 2.28) (p = 0.005), whereas the Corail stem showed a decreased hazard ratio of 0.47 (95% confidence interval, 0.34 to 0.65) (p < 0.0005) compared with the reference Bi-Metric design. CONCLUSIONS The shape and surface finish of the femoral stem and its fixation could be related to the increased risk of some prosthetic designs. Even if the incidence of early periprosthetic fracture in general is low and other reasons for revision must be considered, specific attention should be given to the choice of fixation and stem design in risk groups. LEVEL OF EVIDENCE Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Truike M Thien
- Institute of Clinical Sciences, The Sahlgrenska Academy, University of Göteborg, Box 426, 40530 Göteborg, Sweden. E-mail address for T.M. Thien:
| | - Georgios Chatziagorou
- Institute of Clinical Sciences, The Sahlgrenska Academy, University of Göteborg, Box 426, 40530 Göteborg, Sweden. E-mail address for T.M. Thien:
| | - Göran Garellick
- Institute of Clinical Sciences, The Sahlgrenska Academy, University of Göteborg, Box 426, 40530 Göteborg, Sweden. E-mail address for T.M. Thien:
| | - Ove Furnes
- The Norwegian Arthroplasty Register, Department of Clinical Medicine, University of Bergen, Jonas Lies vei 65, 5021 Bergen, Norway. E-mail address for O. Furnes: . E-mail address for L.I. Havelin:
| | - Leif I Havelin
- The Norwegian Arthroplasty Register, Department of Clinical Medicine, University of Bergen, Jonas Lies vei 65, 5021 Bergen, Norway. E-mail address for O. Furnes: . E-mail address for L.I. Havelin:
| | - Keijo Mäkelä
- Department of Orthopaedics and Traumatology, Turku University Hospital, P.O. Box 52, 20521 Turku, Finland. E-mail address:
| | - Søren Overgaard
- Institute of Clinical Research, University of Southern Denmark, Sdr. Boulevard 29, 5000 Odense, Denmark. E-mail address:
| | - Alma Pedersen
- Department of Clinical Epidemiology, Aarhus University Hospital, Olof Palmes Alle 43-45, 8200 Aarhus, Denmark. E-mail address:
| | - Antti Eskelinen
- The Coxa Hospital for Joint Replacement, Box 652, 33101 Tampere, Finland. E-mail address:
| | - Pekka Pulkkinen
- Department of Public Health, University of Helsinki, Box 41, 00014 Helsinki, Finland. E-mail address:
| | - Johan Kärrholm
- Institute of Clinical Sciences, The Sahlgrenska Academy, University of Göteborg, Box 426, 40530 Göteborg, Sweden. E-mail address for T.M. Thien:
| |
Collapse
|
7
|
Madanat R, Mäkinen TJ, Aro HT, Bragdon C, Malchau H. Adherence of hip and knee arthroplasty studies to RSA standardization guidelines. A systematic review. Acta Orthop 2014; 85:447-55. [PMID: 24954489 PMCID: PMC4164860 DOI: 10.3109/17453674.2014.934187] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Guidelines for standardization of radiostereometry (RSA) of implants were published in 2005 to facilitate comparison of outcomes between various research groups. In this systematic review, we determined how well studies have adhered to these guidelines. METHODS We carried out a literature search to identify all articles published between January 2000 and December 2011 that used RSA in the evaluation of hip or knee prosthesis migration. 2 investigators independently evaluated each of the studies for adherence to the 13 individual guideline items. Since some of the 13 points included more than 1 criterion, studies were assessed on whether each point was fully met, partially met, or not met. RESULTS 153 studies that met our inclusion criteria were identified. 61 of these were published before the guidelines were introduced (2000-2005) and 92 after the guidelines were introduced (2006-2011). The methodological quality of RSA studies clearly improved from 2000 to 2011. None of the studies fully met all 13 guidelines. Nearly half (43) of the studies published after the guidelines demonstrated a high methodological quality and adhered at least partially to 10 of the 13 guidelines, whereas less than one-fifth (11) of the studies published before the guidelines had the same methodological quality. Commonly unaddressed guideline items were related to imaging methodology, determination of precision from double examinations, and also mean error of rigid-body fitting and condition number cutoff levels. INTERPRETATION The guidelines have improved methodological reporting in RSA studies, but adherence to these guidelines is still relatively low. There is a need to update and clarify the guidelines for clinical hip and knee arthroplasty RSA studies.
Collapse
Affiliation(s)
- Rami Madanat
- Helsinki University Central Hospital, Helsinki,Harris Orthopaedic Laboratory, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | | | - Hannu T Aro
- Turku University Hospital and University of Turku, Turku, Finland
| | - Charles Bragdon
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Henrik Malchau
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
8
|
Buchhorn GH, Bersebach P, Stauch T, Schultz W, Köster G. Interface abrasion between rough surface femoral stems and PMMA cement results in extreme wear volumes--a retrieval study and failure analysis. J Biomed Mater Res B Appl Biomater 2014; 103:229-41. [PMID: 24820132 DOI: 10.1002/jbm.b.33202] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2013] [Revised: 03/28/2014] [Accepted: 04/21/2014] [Indexed: 11/11/2022]
Abstract
During the loosening cascade of cemented rough femoral stems, the destruction of the mantle and the production of cement and metal wear debris occur after the loss of constraint at the interface. Two-dimensional (2D) measurements (light microscopy based morphometry on fragments of mantles and vertical scanning interferometry of femoral stems) permitted mathematical 3D-extrapolations to estimate the wear volumes. Fragments of the cement mantles available lost volumes from 0.85 mm(3) to 494.10 mm(3) (median amount of bone cement wear = 178,426 mg). The harder metal surfaces lost between 1.459 mm(3) and 5.688 mm(3) of material (the median amount of metal wear per surface = 1.504 mg/100 mm(2)). Compared to the loss of material due to the fretting of stems, the abrasion of metal, and cement in defective cement mantles produced wear volumes sufficiently high to induce osteolysis. Though the design of the femoral stem and the handling of bone cement do not represent contemporary design and clinical practice, respectively, an extremely high number of joint replacements still in daily use may be impacted by this study because of possible predicted failures. Once the processes of fragmentation, abrasion, and osteolysis have been realized, the time until revision surgery should not be unduly prolonged.
Collapse
Affiliation(s)
- Gottfried Hans Buchhorn
- Department of Orthopaedic Surgery, Fachklinik Lorsch, Waldstrasse 13, 64653, Lorsch, Germany
| | | | | | | | | |
Collapse
|
9
|
Broeke RHMT, Harings SEJM, Emans PJ, Jutten LMC, Kessels AGH, Geesink RGT. Randomized comparison between the cemented Scientific Hip Prosthesis and Omnifit: 2-year DEXA and minimum 10-year clinical follow-up. J Arthroplasty 2013; 28:1354-61. [PMID: 23453292 DOI: 10.1016/j.arth.2012.09.024] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/19/2012] [Revised: 08/26/2012] [Accepted: 09/10/2012] [Indexed: 02/01/2023] Open
Abstract
Radiostereometry (RSA) of the cemented Scientific Hip Prosthesis (SHP) reported excessive migration and predicted high failure rates. In a prospective randomized clinical trial we compared minimum 10 years results of the SHP (n=38) with the Omnifit-stem (n=37). Two-year bone remodelling, compared with dual energy x-ray absorptiometry and assessed in regions of interest A-D based on the 7 Gruen zones, showed better periprosthetic bone preservation around the SHP in all but one regions (P<.05). At 10 years Harris Hip Score was better for the SHP (P=.0001) but Oxford Hip Score was the same (P=.79). There were no revisions in either group, but radiographic loosening was definite in 1 SHP and 1 Omnifit. Based on earlier RSA studies, the rough surface finish of the SHP was expected to cause cement abrasion, osteolysis and inferior survival. However our clinical and remodelling results could not confirm these expectations, suggesting that the link of early migration and mid-term clinical results is not sufficiently clear for the SHP.
Collapse
Affiliation(s)
- René H M Ten Broeke
- Department of Orthopaedic Surgery, Maastricht University Medical Centre, 6202 AZ Maastricht, The Netherlands
| | | | | | | | | | | |
Collapse
|
10
|
Penny JO, Brixen K, Varmarken JE, Ovesen O, Overgaard S. Changes in bone mineral density of the acetabulum, femoral neck and femoral shaft, after hip resurfacing and total hip replacement. ACTA ACUST UNITED AC 2012; 94:1036-44. [DOI: 10.1302/0301-620x.94b8.28222] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
It is accepted that resurfacing hip replacement preserves the bone mineral density (BMD) of the femur better than total hip replacement (THR). However, no studies have investigated any possible difference on the acetabular side. Between April 2007 and March 2009, 39 patients were randomised into two groups to receive either a resurfacing or a THR and were followed for two years. One patient’s resurfacing subsequently failed, leaving 19 patients in each group. Resurfaced replacements maintained proximal femoral BMD and, compared with THR, had an increased bone mineral density in Gruen zones 2, 3, 6, and particularly zone 7, with a gain of 7.5% (95% confidence interval (CI) 2.6 to 12.5) compared with a loss of 14.6% (95% CI 7.6 to 21.6). Resurfacing replacements maintained the BMD of the medial femoral neck and increased that in the lateral zones between 12.8% (95% CI 4.3 to 21.4) and 25.9% (95% CI 7.1 to 44.6). On the acetabular side, BMD was similar in every zone at each point in time. The mean BMD of all acetabular regions in the resurfaced group was reduced to 96.2% (95% CI 93.7 to 98.6) and for the total hip replacement group to 97.6% (95% CI 93.7 to 101.5) (p = 0.4863). A mean total loss of 3.7% (95% CI 1.0 to 6.5) and 4.9% (95% CI 0.8 to 9.0) of BMD was found above the acetabular component in W1 and 10.2% (95% CI 0.9 to 19.4) and 9.1% (95% CI 3.8 to 14.4) medial to the implant in W2 for resurfaced replacements and THRs respectively. Resurfacing resulted in a mean loss of BMD of 6.7% (95% CI 0.7 to 12.7) in W3 but the BMD inferior to the acetabular component was maintained in both groups. These results suggest that the ability of a resurfacing hip replacement to preserve BMD only applies to the femoral side.
Collapse
Affiliation(s)
- J. O. Penny
- University of Southern Denmark, Department
of Orthopaedic Surgery and Traumatology, Odense
University Hospital, Sdr. Boulevard 29, 5000
Odense C, Denmark
| | - K. Brixen
- University of Southern Denmark, Department
of Endocrinology, Odense University Hospital, Sdr.
Boulevard 29, 5000 Odense C, Denmark
| | - J. E. Varmarken
- Naestved Hospital, Department
of Orthopaedic Surgery, Naestved Hospital, Ringstedgade
61, 4700 Naestved, Denmark
| | - O. Ovesen
- University of Southern Denmark, Department
of Orthopaedic Surgery and Traumatology, Odense
University Hospital, Sdr. Boulevard 29, 5000
Odense C, Denmark
| | - S. Overgaard
- University of Southern Denmark, Department
of Orthopaedic Surgery and Traumatology, Odense
University Hospital, Sdr. Boulevard 29, 5000
Odense C, Denmark
| |
Collapse
|
11
|
Nebergall A, Bragdon C, Antonellis A, Kärrholm J, Brånemark R, Malchau H. Stable fixation of an osseointegated implant system for above-the-knee amputees: titel RSA and radiographic evaluation of migration and bone remodeling in 55 cases. Acta Orthop 2012; 83:121-8. [PMID: 22489885 PMCID: PMC3339524 DOI: 10.3109/17453674.2012.678799] [Citation(s) in RCA: 78] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Rehabilitation of patients with transfemoral amputations is particularly difficult due to problems in using standard socket prostheses. We wanted to assess long-term fixation of the osseointegrated implant system (OPRA) using radiostereometric analysis (RSA) and periprosthetic bone remodeling. METHODS 51 patients with transfemoral amputations (55 implants) were enrolled in an RSA study. RSA and plain radiographs were scheduled at 6 months and at 1, 2, 5, 7, and 10 years after surgery. RSA films were analyzed using UmRSA software. Plain radiographs were graded for bone resorption, cancellization, cortical thinning, and trabecular streaming or buttressing in specifically defined zones around the implant. RESULTS At 5 years, the median (SE) migration of the implant was -0.02 (0.06) mm distally. The rotational movement was 0.42 (0.32) degrees around the longitudinal axis. There was no statistically significant difference in median rotation or migration at any follow-up time. Cancellization of the cortex (plain radiographic grading) appeared in at least 1 zone in over half of the patients at 2 years. However, the prevalence of cancellization had decreased by the 5-year follow-up. INTERPRETATION The RSA analysis for the OPRA system indicated stable fixation of the implant. The periprosthetic bone remodeling showed similarities with changes seen around uncemented hip stems. The OPRA system is a new and promising approach for addressing the challenges faced by patients with transfemoral amputations.
Collapse
Affiliation(s)
- Audrey Nebergall
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, MA, USA
| | - Charles Bragdon
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, MA, USA
| | - Anne Antonellis
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, MA, USA
| | | | | | - Henrik Malchau
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, MA, USA
| |
Collapse
|
12
|
Thien TM, Thanner J, Kärrholm J. Fixation and bone remodeling around a low-modulus stem seven-year follow-up of a randomized study with use of radiostereometry and dual-energy x-ray absorptiometer. J Arthroplasty 2012; 27:134-142.e1. [PMID: 21549557 DOI: 10.1016/j.arth.2011.03.029] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2009] [Revised: 12/20/2010] [Accepted: 03/02/2011] [Indexed: 02/01/2023] Open
Abstract
Thirty-eight patients (40 hips) randomly received either an uncemented fully porous-coated composite stem (Epoch; Zimmer, Warsaw, Ind) or an uncemented proximally porous-coated solid stem (Anatomic; Zimmer). Patients were followed up for 7 years using radiostereometry, dual-energy x-ray absorptiometry, conventional radiography, the Harris Hip Score, and a pain questionnaire. Both stem designs achieved excellent outcome for fixation (stem subsidence and stem rotations close to zero) and clinical outcome, without any difference between the 2 groups (P > .12). Median wear rates were low despite use of conventionally gamma-sterilized polyethylene. No stem was radiographically loose on the postoperative radiographs. The low-modulus composite stem had positive effects on early proximal bone remodeling in Gruen regions 1, 2, 6, and 7 (P < .04). However, at 7 years, this bone-sparing effect persisted in only the calcar region (Gruen region 7).
Collapse
Affiliation(s)
- Truike M Thien
- Departments of Orthopaedics, Sahlgrenska University Hospital, University of Gothenburg, Sweden
| | | | | |
Collapse
|
13
|
Abstract
BACKGROUND AND PURPOSE Dual-energy X-ray absorptiometry (DXA) is a precise method to study changes in bone mineral density (BMD), including the pattern of bone remodeling around an implant. Results from implant studies are usually presented as changes in BMD as a function of time. The baseline and reference value for such calculations is the first measurement after the operation. The baseline measurement has been performed at different time points in different studies. If there is rapid bone loss immediately after an operation, this will influence the reference value and hence the results. To evaluate DXA as a method, we studied the very early changes by doing 3 DXA measurements within the first 2 weeks after surgery. PATIENTS AND METHODS We included 23 hips in 23 patients who were operated with an uncemented total hip prosthesis (THP). Each Gruen region was measured with DXA at 1, 5, and 14 days, and 3 and 12 months after the operation. 16 of the patients completed all 5 follow-ups. RESULTS There was no detectable change in BMD in the first 14 days after the operation. In all zones, the lowest BMD was measured after 3 months. INTERPRETATION We conclude that DXA measurements done within 14 days after the operation can be used as reference measurements for later follow-up studies.
Collapse
Affiliation(s)
| | - Tore Heier
- Surgical Department, Diakonhjemmet Hospital, Oslo, Norway
| | | |
Collapse
|